MUP 2024-0004 The Golf Bar (09.25.2024)
September 25, 2024
Hide Iwagami
Hestia Atelier
3 Peters Canyon Rd. #110 Unit
Irvine, CA 92606
SUBJECT: MINOR USE PERMIT 2024-0004 THE GOLF BAR
Dear Mr. Iwagami:
The City of La Quinta Design and Development Department has reviewed and approved Minor
Use Permit 2024-0004, for an indoor commercial recreation center (indoor sports simulators)
located at 79815 Highway 111 Suite 102, pursuant to the findings listed in Section 9.210.025 of
La Quinta Municipal Code, subject to the information on file and attached and the conditions of
approval included herein.
Findings
1. Consistency with General Plan. The proposed use provides entertainment, and indoor
recreation uses consistent with the General Plan designation of General Commercial
(GC) which allows for a wide range of commercial uses.
2. Consistency with Zoning Code. The proposed use is consistent with the Regional
Commercial (CR) zoning designation of this area in that it is a permitted use, and it serves
the local and larger community areas consistent with the intent of the zone.
3. Compliance with CEQA. The Minor Use Permit is exempt from the California
Environmental Quality Act (CEQA) per Section 15301 (a) as it involves the minor
alteration of an existing structure with interior modifications.
4. Surrounding Uses. Approval of the application will not create conditions materially
detrimental to the public health, safety and general welfare or injurious to or incompatible
with other properties or land uses in the vicinity. The proposed use is consistent with other
commercial uses in the shopping center.
Conditions of Approval
1. Changes to the exterior may require additional Building permit approval and approval of
a Modification by Applicant (MBA).
2. The applicant is required to obtain permit approval for interior modifications from the
Building Department and Riverside County Fire Department.
3. Installation of exterior signage requires a separate permit application to be submitted to
the Planning Department.
4. Operations shall be consistent with statement of operations and floor plan on file.
The City may elect to add Conditions to this approval to mitigate any problems that arise not
previously addressed herein. If you have any questions, please contact me at (760) 777-7086.
Sincerely,
Sijifredo Fernandez
Associate Planner
Design and Development Department
cc. Danny Castro, Design and Development Director
1. THE DRAWINGS ARE THE PROPERTY OF HESTIA ATELIER AND ARE NOT TO BE USED FOR ANY OTHER THAN THE LOCATION SHOWN HEREON.2. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOLEGE OR CONSENT OF THE ARCHITECT / ENGINEER WHOSE SIGNATURE APPEARS HEREON. 3. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE SITE DRAWINGS AS SUBMITTED BY THE OWNER AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION`.4. GENERAL CONTRACTOR SHALL CONSULT WITH OWNER'S CONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONS, OR PLAN DISCREPANCIES PRIOR TO BIDDING OR CONSTRUCTION.5. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE, AND FEDERAL CODES AND ORDINANCES.6. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES.
7. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES
REQUIRED BY OTHER TRADES, AND NOTIFY OWNER'S CONSTRUCTION MANAGER
OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK.
8. WALL DIMENSIONS ARE TO THE FACE OF FRAMING / FACE OF STUD - U.N.O. DO NOT
SCALE THESE DRAWINGS
9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE
PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS PRIOR TO
INSTALLATION OF SUCH SYSTEMS.
10. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND
DOCUMENT ALL CHANGES DURING CONSTRUCTION.
11. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN TO PROVIDE
ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL
CONNECTIONS, PLUMBING CONNECTIONS, AND OTHER ITEMS REQUIRED FOR A
COMPLETE AND OPERATION READY INSTALLATION PER MANUFACTURER'S WRITTEN
REQUIREMENTS. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE
ARCHITECT.
12. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND
UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES
(POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS,
APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOKUP. THE
CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER
OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY
CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
13. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS
LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY
CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE
FUEL GAS PIPING." (PER ORDINANCE 170, 158) (INCLUDES COMMERCIAL ADDITIONS
AND TL WORK OVER $10,000.) SEPARATE PLUMBING PERMIT IS REQUIRED.
14. NO FRAMIING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION
15. REFERNCE TO ANY DETAIL OR DRAWING IS FOR REFERENCE ONLY AND DOES NOT
LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. BY GONVERNING
AGENCIES.
CLIENT:THE GOLF BARCONTACT: CHRISTOPHER GO(858) 461-8180thegolfbarlq@gmail.comARCHITECT OF RECORD:HESTIA ATELIER, LLPHIDENORI IWAGAMI3 PETERS CANYON RD. #110IRVINE, CA 92606(626) 222-7669
plancheck@hestiaatelier.com
MEP
CONSULTANT
OF RECORD:
PIVOT ENGINEERS CONSULTANT
CONTACT: MOSTAFA ZUBAIR
(909) 610-5364
mzubair@peccusa.com
PROJECT MANAGER:HESTIA ATELIER, LLPISCOLINA DELGADO3 PETERS CANYON RD. #110IRVINE, CA 92606(626) 222-7669plancheck@hestiaatelier.com
NEW TENANT IMPROVEMENT WITHIN EXISTING SHELL LEASE BUILDING.
CHANGE OF USE OF AN EXISTING (9433 SF) M - OCCUPANCY (TODA MODA) INTO
AN A-2 TYPE OCCUPANCY (GOLF BAR SIMULATOR ASSEMBLY)
SCOPE INCLUDES:
- NEW CASEWORK
- NEW NON-LOAD BEARING INTERIOR PARTITIONS
- NEW BEVERAGE PREP EQUIPMENT
- NEW PLUMBING FIXTURES
- NEW FLOOR FINISH
- NEW WALL FINISH
- CEILING MODIFICATIONS
- NEW INTERIOR LIGHTING
- NEW INTERIOR FURNITURE
THERE IS NO CHANGE TO THE SQUARE FOOTAGE OF THE EXISTING TENANT
SPACE
CODE AUTHORITIES:CITY OF LA QUINTA MUNICPAL CODE
BUILDING CODE: 2022 California Building Code: Chapter 15.
PLUMBING CODE: 2022 California Plumbing Code: Chapter 15.08
MECHANICAL CODE: 2022 California Mechanical Code: Chapter 15.07
ELECTRICAL CODE: 2022 California Electrical Code: Chapter 15.06
ENERGY CODE: 2022 California Energy Code 15.17
FIRE CODE: 2022 California Fire Code
HEALTH CODE: 2022 California Retail Food Code
ACCESSIBILITY CODE: CH 11B OF 2022 CBC
HWY 11JEFFERSON STJEFFERSON STHWY 11
HWY 11 HWY 11N N
Ø DIAMETERSQUARE FOOT / FEET& AND@ ATC CENTER LINEPERPENDICULAR# POUND OR NUMBER(E) EXISTINGA.B. ANCHOR BOLTABV. ABOVEA/C AIR CONDITIONINGA.C. ASPHALTIC CONCRETEACT ACOUSTICAL CEILING TILEADD'L. ADDITIONALA.D. AREA DRAINADJ ADJUSTABLEAFF. ABOVE FLOOR FINISHAGGR. AGGREGATE
ALUM. ALUMINUM
AMP AMPERE
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
ASB. ASBESTOS
ASPH. ASPHALT
ASR. AUTOMATIC FIRE SPRINKLERS
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
BM. BEAM
BOH. BACK OF HOUSE
BOT. BOTTOM
BTWN. BETWEEN
C CAMBER
CAB CABINET
C.B. CATCH BASIN
CEM CEMENT
CER. CERAMIC
C.H.B CONCRETE HOSE BIB
C.I. CAST IRON
C/J CEILING JOINT
CJ CONTROL JOINT
CL CENTER LINE
CLG. CEILING
CLR. CLEAR
CMU CONCRETE MASONRY UNIT
C.O. CONCRETE OPENING CLEANOUT
COL COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
CORR. CORRIDOR
CTSK. COUNTERSUNK
CTR. CENTER
CX COMMISSIONING
CXA COMMISSIONING AGENT
CY CUBIC YARD
DBL. DOUBLE
DEG DEGREE
DEPT. DEPARTMENT
DET. DETAIL
D.F. DRINKING FOUNTAIN
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
DN. DOWN
DR. DOOR
DS. DOUNSPOUT
D.S.P DRY STANDPIPE
DWG DRAWING
E. EAST
EA. EACH
EJ EXPANSION JOINT
ELEC. ELECTRICAL
EL. ELEVATION
EMER. EMERGENCY
ENCL. ENCLOSURE
E.P. ELECTRICAL PANEL
EPS EXPANDED POLYSTYREN
EQ. EQUAL
EQUIP. EQUIPMENT
E.W. EACH WAY
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FA FIRE ALARM
FDN FOUNDATION
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.F. FLOOR FINISH
FF&E FURNITURE, FIXTURE,
AND EQUIPMENT
FIN. FINISH
FIXT. FIXTURE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.H.C FIRE HOSE CABINET
F.H FIRE HYDRANT
FL. FLOW LINE
F.O.C FACE OF CONCRETE
F.O.F FACE OF FINISH
FOH FRONT OF HOUSE
F.O.M FACE OF MASONRY
F.O.S FACE OF SHEATHING
FPRF. FIREPROOF
FRT. FIRE RETARDANT TREATED
F.S. FINISH SURFACE
F.S. FLOOR SINK
FSR. FIRE SPRINKLER RISER
FT. FOOT OR FEET
FTG. FOOTING
FURR. FURRING
FUT. FUTURE
G GROUND
GA GAUGE
GALV. GALVANIZED
G.B. GRAB BAR
GC GENERAL CONTRACTOR
GI. GREASE INTERCEPTOR
GL. GLASS
GND. GROUND
GR. GRADE
GWB GYPSUM WALLBOARD
GYP GYPSUM
H.B. HOSE BIB
H.C. HOLLOW CORE
HDR. HEADER
HDW. HARDWARE
HDWD. HARDWOOD
HM. HOLLOW METAL
HORIZ. HORIZONTAL
H.P. HIGH POINT
HR. HOUR
L HT. HEIGHTHVAC. HEATING, VENTALATION & AIR CONDITIIONINGI.D. INSIDE DIAMETERI.E. INVERT ELEVATIONIN. INCHINFO. INFORMATIONINSUL. INSULATIONINT. INTERIORJT. JOINTLAM. LAMINATELAV. LAVATORYLEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGNLL LANDLORDLT. LIGHT
LV LOW VOLTAGE
MAX. MAXIMUM
MECH. MECHANICAL
MEMB. MEMBRANE
MET. METAL
MFR. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MTD. MOUNTED
MUL. MULLION
N. NORTH
N.F.A NET FREE VENT AREA
NIC NOT IN CONTRACR
NL NIGHT LIGHT
NO. NUMBER
NOM. NOMINAL
N.T.S NOT TO SCALE
O.A. OVERALL
OBS. OBSCURED
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OFD. OVERFLOW DRAIN
OFF. OFFICE
OPNG. OPENING
OPP. OPPOSITE
PART'N PARTITION
PIR PASIVR INFRARED SENSOR
P.L. PROPERTY LINE
PL. PLATE
P.LAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLC PLACE
PLYWD. PLYWOOD
POC POINT OF CONNECTION
PR. PAIR
P.T. PRESSURE TREATED
Q.T. QUARRY TILE
R. RISER
R./RAD. RADIUS
R.D. ROOF DRAIN
RDWD. REDWOOD
RE. REFER TO
REF. REFERENCE
REFR. REFRIGERATOR
REG. REGISTER
REINF. REINFORCING
REQ'D REQUIRED
REQ'M REQUIREMENT
RESIL. RESILIENT
REV REVISION
R.H.B RECESSED HODE BIB
RM. ROOM
RND ROUND
R.O. ROUGH OPENING
ROM. RIGHT OF WAY
R.S. ROUGH SAWN
R.W.L RAIN WATER LEADER
S. SOUTH
SAT SUSPENDED ACOUSTIC TILE
S.C. SOLID CORE
SCHED. SCHEDULE
SECT. SECTION
S.F. SQUARE FOOT/FEET
SHT. SHEET
SHT'G SHEATHING
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
SSK. SERVICE SINK
STA. STATION
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURAL / STRUCTURE
SUSP. SUSPENDED
SYM. SYMETRICAL
T. TREAD
TB. TOP BEAM
TC. TOP OF CURB
TD. TOP OF DRAIN
TEL. TELEPHONE
TEMP. TEMPORARY
T&G TONGUE AND GROOVE
T.J. TRUSS JOINT
T.O. TOP OF
T.O.C TOP OF CONCRETE
T.O.P TOP OF PARAPET
T.O.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE
T.O.W TOP OF WALL
T.P. TOP OF PAVEMENT
T.V. TELEVISION
TYP. TYPICAL
UC. UNDER COUNTER
UNF. UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
VEST. VESTIBULE
V.C.T. VINYL COMPOSITE TILE
V.I.F VERIFY IN FIELD
V.T.R VENT THROUGH ROOF
W WEST
W/ WITH
W.C. WATER CLOSET
WD. WOOD
WH. WATER HEATER
W/O WITHOUT
WP. WATERPROOF
WR. WATER RESISTANT
W.W.F. WELDED WIRE FABRIC
WT. WEIGHT
X' XX"
XN
NORTH
ARROW
XXXX AFF
XXXXXW
XXScale: X =X0 2 4 8GRAPHIC SCALE DATUM POINT EXTERIORELEVATIONCALL-OUT INTERIORELEVATION CALL-OUT
SECTION
CALL-OUT
DETAIL CALL-OUT
REVISION
TAG
PAINT
TAG
DESIGN ID
TAG
DOOR
TAG
WINDOW
TAG
SHEET NOTE CALLOUT ABOVE FINISH FLOOR HEIGHT TAG FINISH FACE TO FINISH FACE DIMENSION REVISION CLOUD
X-X-XPTXXXXXXXXXXX XXXXXD XX
INTERIOR
WALL TAG
ZONING:
PARCEL NUMBER: 600440007
LEGAL DESCRIPTION: PARCEL 3 OF PARCEL MAP 33960
SECTION 11
PERMITTED LAND USE: COMMERCIAL
ZONING: CR - REGIONAL COMMERCIAL
CURRENT USE: CLOTHING RETAIL
PROPOSED USE: GOLF BAR / SIMULATOR
OCCUPANCY TYPE: A-2
BUILDING AREA: 19,931 SF
TENANT AREA: 9433 SF
CONSTRUCTION TYPE: V-B
FIRE SPRINKLER: YES
MAX EMPLOYEES PER SHIFT: 6
SHEET INDEXSYMBOLS LEGEND GENERAL NOTESABBREVIATIONS LIST PROJECT CONTACTS
CODE INFORMATION
BUILDING INFORMATION
VICINITY MAP
5583 CLAIRMONT MESA BLVD
SAN DIEGO, CA 92117STATEOFCALIFRNIAO
REN.09/30/25
S
LICENDARC
H
I
TE
CTE
HID ENOR I I WAG
A
MIC-34970
3 PETERS CANYON RD. #110IRVINE, CA. 92606DGESIN|ARCHITECTUREH E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
PROJECT #:
ISSUE DATE:
CONSULTANT
DESIGN MANAGER:
PRODUCTION
DESIGNER:
CHECKED BY:
SEAL
7/29/2024 10:11:06 AMD:\Hestia Atelier Dropbox\Projects\One-Off\La Quinta 79815 HWY 111 Golf Bar\CD\The Golf Bar - La Quinta - Revit Model.rvtT1.0
HA2024-102
5/3/2024THE GOLF BAR -LAQUINTA79-815 HWY. 111 SUITE 102LA QUINTA, CA 92253ISCOLINA D.
TAMEEM H.
ISCOLINA D.
GENERAL
INFORMATION1ST PERMIT SUBMITTAL - 07/19/2024
SCOPE OF WORK DEFERRED SUBMITTALS
SEPARATE SUBMITTALS
1. FIRE SPRINKLERS TO BE SUBMITTED UNDER DEFERRED SUBMITTAL -
CONTRACTOR TO SUBMIT SHOP DRAWINGS / PLANS TO THE APPLICABLE
GOVERNING AGENCY FOR REVIEW AND APPROVAL
1. EXTERIOR SIGNAGE TO BE SUBMITTED UNDER SEPARATE REVIEW AND
APPROVAL
SHEET SHEET TITLE BID SET PERMIT SET REVISION 1 REVISION 2 REVISION 3 REVISION 4 TILET1.0 GENERAL INFORMATIONARCHITECTURALA0.1 OVERALL SITE PLANA1.0 BUILDING FLOOR PLANA1.6 FF & E PLANA3.0 BUILDING EXTERIOR PHOTOGRAPHSNUMBER OF SHEETS: 5
LOCATION MAP
Revision Schedule
Rev Date By Description
PLANNING APPROVAL
ADMINISTRATIVE
CASE # ____________________
EXHIBIT # ____________________
INITIAL :
DATE :
MUP2024-0004
sfernandez
09/25/2024 5:14:31PM
A. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION.B. PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT TRANSITION FROM SIDEWALK TO DRIVE AISLE.C. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS.D. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK. (WHEN APPLICABLE)E. EXISTING SITE FEATURES TO REMAIN, NO CHANGE U.N.OGENERAL NOTES
SITE PLAN KEYNOTES
1 EXISTING LANDSCAPED AREA TO REMAIN.
4 EXISTING ACCESSIBLE PARKING TO REMAIN. REFER TO 1/G005 FOR
MORE INFORMATION
5 EXISTING PARKING STALL TO REMAIN.
7 EXISTING PUBLIC RIGHT OF WAY
8 EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING DEDICATED
AREA FOR RECYCLING.
2 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO ACCESSIBLE
PARKING -REFER TO 1/G005.
6 THE GOLF BAR, AREA OF WORK.
3 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF
WAY -REFER TO 1/G005.
12 EXISTING WATERMAIN TO REMAIN
13 EXISTING ELECTRICAL ROOM TO REMAIN (NIS).
14 EXISTING ROOF ACCESS/FIRE RISER ROOM TO REMAIN (NIS).
11 EXISTING BACK DOOR TO REMAIN (NIS).
9 EXISTING MAIN ENTRY/EXIT DOOR TO REMAIN (NIS).
10 EXISTING EMERGENCY EXIT ONLY DOOR TO REMAIN (NIS).
EXISTING LANDSCAPE AREA
LEGEND
EXISTING 6" (150MM) CONCRETE CURB
ACCESSIBLE PATH OF TRAVEL
1 1
1
1
1
1
1 1 1 11
1
1
11 1 11
1
1
1
1
1
1
1
1
1
1
1
11 1 1
11
1
1
1
1
1
1
1
2
2
3
3
3
3
3
3 7777
4
4
4
4
4
5 5
5 5
5 5
5 5
5 5
5 5
5 5
5 5
5 5
5 5
5 5
5 5
5
5 5
5 5
5
5
5
5
8
8
6
55
1
1 1
8
55
HWY 111
DEPOT DRIVE(E) ADJECENT TENANT
TO REMAIN (NIS)
(E) ADJECENT BUILDING
TO REMAIN (NIS)
9
10
11
12
1314
5
A2.0
3
5583 CLAIRMONT MESA BLVD
SAN DIEGO, CA 92117STATEOFCALIFRNIAO
REN.09/30/25
S
LICENDARC
H
I
TE
CTE
HID ENOR I I WAG
A
MIC-34970
3 PETERS CANYON RD. #110IRVINE, CA. 92606DGESIN|ARCHITECTUREH E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
PROJECT #:
ISSUE DATE:
CONSULTANT
DESIGN MANAGER:
PRODUCTION
DESIGNER:
CHECKED BY:
SEAL
7/29/2024 10:11:09 AMD:\Hestia Atelier Dropbox\Projects\One-Off\La Quinta 79815 HWY 111 Golf Bar\CD\The Golf Bar - La Quinta - Revit Model.rvtA0.1
HA2024-102
5/3/2024THE GOLF BAR -LAQUINTA79-815 HWY. 111 SUITE 102LA QUINTA, CA 92253ISCOLINA D.
TAMEEM H.
ISCOLINA D.
OVERALL SITE PLAN1ST PERMIT SUBMITTAL - 07/19/2024
N
1" = 30'-0"1ARCHITECTURAL SITE PLAN
Revision Schedule
Rev Date By Description
KEYNOTES GENERAL NOTESA. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY OWNER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT.B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING, OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT AND/OR SIGNAGE.C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE CODE, REMOVE AND REPLACE WITH ACCESSIBLE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN 1:12.D. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS SHOWN OR NOTED OTHERWISE.E. GENERAL CONTRACTOR TO PROVIDE WATER RESISTANT TYPE 'X' GYP. BD. AT RESTROOM AND BACKBAR WALLS (ALL WET WALLS).11 NEW RESTROOM DOOR. FINISH PER ELEVATIONS9ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM CLEARANCE ASREQUIRED BY CODE.8 DIMENSION CONTROL DATUM POINT.13 DASHED LINE INDICATES HEADER ABOVE12NEW TRAFFIC SWINGING DOOR. NO LATCH OR LOCK PROVIDED10ALIGN FACE OF FINISHED WALL.14 OUTLINE OF BAR PER CASEWORK MANUFACTURER.F. ALL DOORS SHALL BE 32” (815MM) MINIMUM CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION UNLESS OTHERWISE NOTED.G. SEE SHEET A6.0 FOR EXTERIOR DOOR AND WINDOW SCHEDULES.H. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE CITY.I. SEE STRUCTURAL FOR KNEE WALL BRACING IF APPLICABLE.J. SEE SHEET A5.1 FOR BUILDING DETAILS IF APPLICABLE.K. REFER TO SHEET A1.11 FOR FLOOR FINISHES.L. PATCH AND REPAIR WALLS AS NECESSARY TO PROVIDE A FINISH READY SURFACE.1 PROVIDE ADEQUATE REINFORCEMENT AND / OR BLOCKING ASREQUIRED TO SUPPORT WALL ATTACHMENTS -REFER TO WALLBLOCKING KEY.6 EXISTING ELECTRICAL PANELS TO REMAIN.7 PROVIDE NEW ELECTRICAL PANELS.3 NEW STOREFRONT TO MATCH EXISTING.2 EXISTING STOREFRONT TO REMAIN.4 EXISTING ENTRY/EXIT DOOR TO REMAIN.5 EXISTING SERVICE DOOR TO REMAIN.15 GYP. START AT 10' -0" AFF AND ABOVE166" LOW WALL UP TO 60" AFF -PLYWOOD SHEATHING ON SIMULATORSIDE WITH GYP SHEATHING ON OPPOSITE SIDEGENERAL LEGEND
NEW PARTIAL HEIGHT WALL
NEW FULL HEIGHT WALL
EXISTING WALL
WALL BLOCKING CALL-OUT
-
X WALL TYPE TAG
DATUM POINT
WALL BLOCKING KEYITEMTYPE FROM 2' - 6" TO6' - 6" AFFHEIGHT A.F.F.EXTENT OF FULL WALL WIDTHAPPROX. WIDTHFROM 2' - 6" TO3' - 0" AFF 60" AROUND WATER CLOSETCOMMERCIAL INSTALLATION REQUIRES CONCEALED ARM CARRIER. REFER TO MFR'S SPECIFICATION.KITCHEN BLOCKINGRESTROOM GRAB BARSRESTROOMURINALABCDEFGMERCHANDISE DISPLAY BLOCKING SPECIFIED BY OWNERWALL-MOUNT TELEVISION (ABOVE)SYMBOL BAR SHELVES / DISPLAY COMMERCIAL INSTALLATION REQUIRES CONCEALED ARM CARRIER. REFER TO MFR'S SPECIFICATION.RESTROOM LAVATORIES 5/8" PLYWOOD5/8" PLYWOOD5/8" PLYWOOD5/8" PLYWOOD5/8" PLYWOOD5/8" PLYWOOD5/8" PLYWOOD BLOCKING SPECIFIED BY OWNERBLOCKING SPECIFIED BY OWNER
1 NEW 6" FULL HEIGHT WALL
6" X 20 GA. METAL STUDS @16" O.C. WITH
5/8" TYPE "X" GYP. BD. ON BOTH SIDES TO 6"
ABOVE CEILING - USE WATER RESISTANT
GYP. BD. ON WET WALLS - DRYWALL
SCREWS @ 12" O.C.
9
SEE WALL STUD TABLE SHEET A5.1
WALL TYPES
A5.1
NEW 3 5/8" FURRED FULL HEIGHT
WALL
3 5/8" X 20 GA. METAL STUDS @
16" O.C. WITH 5/8" TYPE "X" GYP.
BD. ON ONE SIDE TO 6" ABOVE
CEILING - USE WATER RESISTANT
GYP. BD. ON ALL WET WALLS -
DRYWALL SCREWS @ 12" O.C.
3
NEW 6" PARTIAL HEIGHT WALL - UP TO 6"
ABOVE CEILING
6" X 20 GA. METAL STUDS @ 16" O.C. WITH
5/8" TYPE "X" GYP. BD. ON BOTH SIDES TO
6" ABOVE CEILING - USE WATER RESISTANT
GYP. BD. ON ALL WET WALLS - DRYWALL
SCREWS @ 12" O.C.
2 13
A5.1
9
A5.1
NEW 3 5/8" PARTIAL HEIGHT (LOW
WALL) - HEIGHT VARIES PER PLAN
3 5/8" X 20 GA. METAL STUDS @
16" O.C. WITH 5/8" TYPE "X" GYP.
BD. BOTH SIDES - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12"
O.C.
4 1
A5.3
NEW 6" FURRED FULL HEIGHT WALL
6" X 20 GA. METAL STUDS @ 16"
O.C. WITH 5/8" TYPE "X" GYP. BD.
ON ONE SIDE TO 6" ABOVE
CEILING - USE WATER RESISTANT
GYP. BD. ON ALL WET WALLS -
DRYWALL SCREWS @ 12" O.C.
NEW 3 5/8" FURRED PARTIAL HEIGHT -
UP TO 10' - 0" AFF
3 5/8" X 20 GA. METAL STUDS @
16" O.C. WITH 5/8" TYPE "X" GYP.
BD. ON ONE SIDE TO 10' - 0" AFF -
USE WATER RESISTANT GYP. BD.
ON ALL WET WALLS - DRYWALL
SCREWS @ 12" O.C.
7 13
A5.1
8
A5.1
EXISTING WALL
17
FINISH MAY OCCUR - SEE WALL FINISH
PLAN & INTERIOR ELEVATIONS - TYP.NEW 3 5/8" FURRED PARTIAL HEIGHT
(LOW WALL) - UP TO 60" AFF
3 5/8" X 20 GA. METAL STUDS @
16" O.C. WITH 5/8" PLYWOOD
SHEATHING ON ONE SIDE - UP
TO 60" AFF - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @
12" O.C.
5 1
A5.2
NEW 3 5/8" PARTIAL HEIGHT (LOW
WALL) - UP TO 6" ABOVE CEILING
3 5/8" X 20 GA. METAL STUDS @
16" O.C. WITH 5/8" TYPE "X" GYP.
BD. ON BOTH SIDES TO 6" ABOVE
CEILING - USE WATER RESISTANT
GYP. BD. ON ALL WET WALLS -
DRYWALL SCREWS @ 12" O.C.
6
13
A5.1
9 NEW 6" FULL HEIGHT
SIMULATOR WALL
6" X 20 GA. METAL STUDS @16"
O.C. WITH 5/8" TYPE "X" GYP. BD.
ON BOTH SIDES TO 6" ABOVE
CEILING - USE WATER RESISTANT
GYP. BD. ON WET WALLS -
DRYWALL SCREWS @ 12" O.C.
A5.1
9
NEW 3 5/8" FURRED PARTIAL
HEIGHT - UP TO 10' - 0" AFF
3 5/8" X 20 GA. METAL STUDS @
16" O.C.
10
13
A5.1
GYP. BD
START @
10' AFF
A
A
D
E G F EG
G
A
A
A
C C
26' - 0 3/4"2' - 0 3/4"15' - 2 1/2"42' - 4 3/4"20' - 5"
17' - 5 3/4"16' - 8 3/4"1' - 8 1/2"16' - 8 3/4"1' - 8 1/2"16' - 11 3/4"
16' - 11 3/4"2' - 1 1/4"18' - 0 3/4"
37' - 1 1/2"16' - 5"1' - 8 1/2"5"5' - 6 3/4"1' - 10 1/4"3' - 10 1/4"8' - 5"10' - 0 1/4"8' - 5"2' - 0 3/4"43' - 1 3/4"9' - 6 3/4"10' - 0"20' - 5"5' - 7 1/4"7' - 1 1/4"
1
BREAK
ROOM
STORAGE
ROOM
EVENT ROOM
SIM 6
MEN'S RR
OFFICE RR
OFFICE
SIM 1
SIM 2
SIM 3 SIM 4 SIM 5
HALLWAY 1 SERVICE
LADDER
ROOM
UTILITIES /
ELECTRICAL
KITCHEN
BAR
SEATING
AREA...2
3
2
6
7
8
88
WOMEN'S RR
SIM 7
LOBBY /
ENTRANCE
T.O. WALL @
33 1/4" AFF
T.O. WALL @
33 1/4" AFF
T.O. WALL @
41 1/4" AFF
T.O. WALL @
41 1/4" AFF
T.O. WALL
@ 39" AFF
T.O. WALL
@ 39" AFF
T.O. WALL
@ 39" AFF
T.O. WALL
@ 39" AFF
T.O. WALL
@ 39" AFF
9' - 2 3/4"39' - 5 3/4"8' - 5"10' - 0 1/4"8' - 5"10' - 0 1/4"8' - 5"
HALLWAY 29' - 5 1/2"9' - 6 1/4"11' - 0 3/4"5' - 5 1/2"5' - 7"4' - 9 3/4"11' - 5 1/4"2' - 1"8' - 5"10' - 5"8' - 5"3' - 10 1/4"
5' - 10"19' - 7 1/4"10' - 4 1/4"6"17' - 3 1/2"3' - 1 1/4"5' - 6"T.O. WALL @
41 1/4" AFF
43' - 11 3/4"39' - 7 3/4"1' - 5 3/4"1' - 1 1/4"
9' - 5 1/2"9' - 6"
SEATING
AREA
7' - 7 3/4"17' - 3 1/2"1' - 4 1/4"2' - 1"3' - 5"5' - 2 1/2"13' - 9 1/4"E E
9 10
10 10
10
13
1414 14
14 14
14
14
14 144
4 4 4
4 4
1
1 1
5 3
3
9
5
1010
5
9
5
10 10
5
1
5
1010
5
5
5 5 3
3
3
5
8 8
8 8
1
4
1
6
1 1
6 2 6 6
3
11
10
3
3
10
4
4
8
6
1 1
4
5
5
5
4
9
1
4
4
4
4
1
1
A2.0
2
12.4
..4
5
T.O. WALL @
33 1/4" AFF
T.O. WALL @
33 1/4" AFF
4
T.O. WALL
@ 39" AFF
T.O. WALL
@ 39" AFF
A2.0
1
..2
2
D 855 23
D 850 22 D 850 21 D 850 20
D 820 30
D 850 31 D 850 32 D 850 29
D 850 33
111111
1
1
10
B B
B
D 840 34
F.O.F. - TYP.HOLD 16' - 5" CLR.1' - 2"D 855 19
A5.2
1
TYP.
F.O.F. - TYP.
HOLD 7' - 0" CLR.
D 14
77
7
7
3
15
15
F.O.F. - TYP.
HOLD 8' - 0" CLR.
F.O.F. - TYP.
HOLD 9' - 6" CLR.
T.O. WALL @
60" AFF
10
10
10
TYP.
TYP.
10
TYP.
TYP.16
10
TYP.
10
TYP.
4 T.O. WALL @
33 1/4" AFF
5583 CLAIRMONT MESA BLVD
SAN DIEGO, CA 92117STATEOFCALIFRNIAO
REN.09/30/25
S
LICENDARC
H
I
TE
CTE
HID ENOR I I WAG
A
MIC-34970
3 PETERS CANYON RD. #110IRVINE, CA. 92606DGESIN|ARCHITECTUREH E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
PROJECT #:
ISSUE DATE:
CONSULTANT
DESIGN MANAGER:
PRODUCTION
DESIGNER:
CHECKED BY:
SEAL
7/29/2024 10:11:11 AMD:\Hestia Atelier Dropbox\Projects\One-Off\La Quinta 79815 HWY 111 Golf Bar\CD\The Golf Bar - La Quinta - Revit Model.rvtA1.0
HA2024-102
5/3/2024THE GOLF BAR -LAQUINTA79-815 HWY. 111 SUITE 102LA QUINTA, CA 92253ISCOLINA D.
TAMEEM H.
ISCOLINA D.
BUILDING FLOOR
PLAN1ST PERMIT SUBMITTAL - 07/19/2024
N
3/16" = 1'-0"1FLOOR PLAN
Revision Schedule
Rev Date By Description
SBSBSBSBSBSB
18x3624x6024x60
24x4824x48
18x60 24x30EXPO18x36 18x36
18x30COCAGENERAL NOTESA. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED.B. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT.C. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS.D. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET.E. SEE SHEET A6.0 FOR SCHEDULES.F. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF APPLIED WALL TREATMENT.
G. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES.
H. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS,
CASTERS OR MANUFACTURER SUPPLIED SKIDS.
I. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI
CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE
CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF SIX
INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE
INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING. ALL
EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO THE
WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH SNEEZE
GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND
UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED.
J. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING) IF APPLICABLE PER SCOPE.K. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW CORNING BRAND '732 MULTI PURPOSE SEALANT'.L. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.M. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED.N. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING.O. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE).P. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN.
Q. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE
LOCAL JURISDICTION.
15 DATA PORT LOCATION. T.O. RECEPTACLE @ 28" AFF. SEEELECTRICAL SHEETS.16 TOUCHSCREEN AND SOUNDBAR LOCATION. WALL PENETRATIONWITH MUD RING @ 56" AFF. SEE ELECTRICAL SHEETS.17 TELEVISION ELECTRICAL DUPLEX AND DATA LOCATION ABOVE. T.O.RECEPTACLE @ 80" SEE ELECTRICAL SHEETS.KEYNOTES1ACCESSIBLE 30" X 48" CLEAR SPACE FOR WHEELCHAIR2EXISTING ELECTRICAL PANEL TO REMAIN3NEW ELECTRICAL PANEL. SEE ELECTRICAL DRAWINGS FOR MOREINFORMATION5FIRE EXTINGUSHER -TYPE 2A10BC PER CFC 9067NEW MERCHANDISE DISPLAY9HAND SINK W/ INTEGRAL SPLASH GUARD.6 INSTALL NEW INTERIOR FURNITURE THROUGHOUT AS SHOWN.4 CLEAR SPACE AT ELECTRICAL PANELS.
10 ACCESSIBLE 60" DIA. CLEAR SPACE FOR WHEELCHAIR
11 METRO RACKS. TOP SHELF NOT TO EXCEED 5'-9" AFF.
12 ELECTRICAL DUPLEX LOCATION. T.O. RECEPTACLE @ 28" AFF. SEE
ELECTRICAL SHEETS.
8 EXISTING ROOF ACCESS RADDER TO REMAIN.
13 ELECTRICAL DUPLEX LOCATION ABOVE WORKTABLE SURFACES
AND BELOW BAR COUNTERTOPS. PLACED SIDEWAYS -T.O.
RECEPTACLE @ 41" AFF AT KITCHEN, AND 39" AFF AT BAR. SEE
ELECTRICAL SHEETS.
14 ELECTRICAL QUADRUPLEX LOCATION. T.O. RECEPTACLE @ 28" AFF.
SEE ELECTRICAL SHEETS.
18 CEILING MTD. DEDICATED DUPLEX ABOVE. SEE ELECTRICALSHEETS.19 DEDICATED DUPLEX ABOVE. T.O. RECEPTACLE @ 104" AFF. SEEELECTRICAL SHEETS.20 DEDICATED J-BOX ABOVE. T.O. RECEPTACLE @ 80" AFF. SEEELECTRICAL SHEETS.21 SUGGESTED LOCATION FOR HVAC THERMOSTAT. COORDINATEWITH CONSTRUCTION MANAGER FOR FINAL LOCATION. (3)
22 SUGGESTED LOCATION FOR HVAC TEMPERATURE SENSOR.
COORDINATE WITH CONSTRUCTION MANAGER FOR FINAL
LOCATION. (4)
23 DASHED LINE INDICATES GLYCOL CHILLER ABOVE WALK-IN FRIDGE
UNIT
24 MINI-PUTTING GREEN
25 EMPLOYEE LOCKERS (6 LOCKERS)
HALLWAY 2
BREAK
ROOM
STORAGE
ROOM
EVENT ROOM
MEN'S RRWOMEN'S RR OFFICE RR
OFFICE
HALLWAY 1
SERVICE
LADDER
ROOM
UTILITIES /
ELECTRICAL
KITCHEN
BAR
1
1
1
1
1
111111
1
1
1 32
4
6
6
7 7
7
7
7
7
10
1010
10
8
SEATING
AREA
LOBBY /
ENTRANCE
SEATING
AREA
A4.0
2
9
9
11 A4.0
1
19
12
12
12 12
1616
16 16
16
19
12
18
18
15
181818
1515
18 18
15 15
16
16 14
12
12 12
12
13
14
12 12
12121212
12 12 12
12
1
7
7' - 2"7' - 2"7' - 2"2' - 6"
6
141414
14 14
15
15
13
13
13
12
12
13
14
19
12
20
J J
17
P 030
23
17
J
20
21
22
22
22
(ABOVE)(ABOVE)(ABOVE)
(ABOVE)(ABOVE)
(ABOVE)
(ABOVE)(ABOVE)(ABOVE)
(ABOVE)(ABOVE)17
20
(ABOVE)
(ABOVE)
(ABOVE)
J
20
5
5
5
(ABOVE)
A4.1
1
SIM 7SIM 6
SIM 1
SIM 2
SIM 3 SIM 4 SIM 5
24
P 029
E 084
P 025
E 088 E 093
P 026
E 070
2' - 10" AFF
2' - 10" AFF (TYP.)
2' - 10" AFF (TYP.)
2' - 10" AFF (TYP.)
2' - 10" AFF
25
3' - 7" AFF 3' - 6" AFF
2' - 10" AFF
5583 CLAIRMONT MESA BLVD
SAN DIEGO, CA 92117STATEOFCALIFRNIAO
REN.09/30/25
S
LICENDARC
H
I
TE
CTE
HID ENOR I I WAG
A
MIC-34970
3 PETERS CANYON RD. #110IRVINE, CA. 92606DGESIN|ARCHITECTUREH E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
PROJECT #:
ISSUE DATE:
CONSULTANT
DESIGN MANAGER:
PRODUCTION
DESIGNER:
CHECKED BY:
SEAL
7/29/2024 10:11:17 AMD:\Hestia Atelier Dropbox\Projects\One-Off\La Quinta 79815 HWY 111 Golf Bar\CD\The Golf Bar - La Quinta - Revit Model.rvtA1.6
HA2024-102
5/3/2024THE GOLF BAR -LAQUINTA79-815 HWY. 111 SUITE 102LA QUINTA, CA 92253ISCOLINA D.
TAMEEM H.
ISCOLINA D.
FF & E PLAN1ST PERMIT SUBMITTAL - 07/19/2024
3/16" = 1'-0"1FURNITURE, FIXTURES AND EQUIPMENT PLAN
N
NOT USED
Revision Schedule
Rev Date By Description
N
5583 CLAIRMONT MESA BLVD
SAN DIEGO, CA 92117STATEOFCALIFRNIAO
REN.09/30/25
S
LICENDARC
H
I
TE
CTE
HID ENOR I I WAG
A
MIC-34970
3 PETERS CANYON RD. #110IRVINE, CA. 92606DGESIN|ARCHITECTUREH E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
PROJECT #:
ISSUE DATE:
CONSULTANT
DESIGN MANAGER:
PRODUCTION
DESIGNER:
CHECKED BY:
SEAL
7/29/2024 10:11:17 AMD:\Hestia Atelier Dropbox\Projects\One-Off\La Quinta 79815 HWY 111 Golf Bar\CD\The Golf Bar - La Quinta - Revit Model.rvtA3.0
HA2024-102
5/3/2024THE GOLF BAR -LAQUINTA79-815 HWY. 111 SUITE 102LA QUINTA, CA 92253ISCOLINA D.
TAMEEM H.
ISCOLINA D.
BUILDING EXTERIOR
PHOTOGRAPHS1ST PERMIT SUBMITTAL - 07/19/2024
Revision Schedule
Rev Date By Description
7/28/2024
To Whom it may concern,
The Golf Bar offers guests the ability to play or practice golf on high tech simulators used by
professionals. In addition, we offer food and beverage service. All ages are welcome.
Exact hours of operation are not defined, but will not start any earlier than 9a and end no later than
11pm. Our typical operations will have approximately 5-7 employees at any given time, with a
roster nearing 15 in total.
With our previous locations, we have successfully secured and maintained CA sellers permit and
ABC licensing, county health permits, and city business use approvals.
Our golf simulators are industry leading computers and cameras made by Full Swing Golf. Our
kitchen equipment is an assemble and warm kitchen using Turbochef self convection ovens. We do
not cook with any open flames or require gas. We require all staff to maintain a valid California
Food Handler’s permit, and for those serving alcohol, a valid ABC Responsible Beverage Serving
permit as well.
Our business is unlike traditional restaurants as it provides our guests an opportunity to use
extremely high end, state of the art technology only previously available to the extremely wealthy or
professional athlete in a very accessible manner. We offer family friendly fun in an environment
that encourages sport and activity. As our mission goes beyond our own success, we’ve
consistently held our charitable fundraisers for the youth in hopes that they will find a strong work
ethic, discipline, and character in this sport. We believe that the city of La Quinta will not only
welcome our business with open arms, but also benefit from what we have to offer.
Should there be further questions about The Golf Bar, please do not hesitate. We welcome the
opportunity to elaborate more on the business and answer any questions you may have.
Thank you,
Christopher Go
President