Loading...
BRES2021-0518 Plans Revision 1the edifice groupJaime E. Mencia945 E 13800 SDraper UT 84020818–648–1078edificegroup@sbcglobal.netDESIGN+BUILDFLOOR PLAN job drawn by scale sheet date revisions contents The use of these plans andspecifications shall be limitedto the use of the original sitefor which they were preparedand publication thereof isexpressly limited to such use.Reproduction publication andor reuse by any method, inw h o l e o r i n p a r t , i sprohibited. Title to the plansand specifications remain withthe designer, Jaime E.Mencia.shown JAT/JEMPROPERTY DATAA.5 0817/2112PROPOSED REMODEL FOR forJ. KONRAD57350 PENINSULA LN. LOT 4, PENINSULA PARK, PGA WEST, LA QUINTA, CA. 92254JOB ADDRESS: 57350 Peninsula Ln. PENINSULA PARK. CA 92254 OWNER: JACKIE KEEHN/RICHARD ROAT (818) 905 5054 DESIGN: Jaime E. Mencia @ THE EDIFICE GROUP ZONE: RL- LOW DENSITY RESIDENTIAL LEGAL DESCRIPTION:LOT 4 TRACT 28522, MB 274/042 LOT SIZE: 23,280 square feet11/18/11 corrections 2/29/12 corrections 2/20/15 POST PERMIT REV. 55 gal WH 4/15/15 POST PERMIT REV. 8/1/21 POST PERMIT REV. 9/30/21 POST PERMIT REV. 1/26/22 POST PERMIT REV.WDDW LAUNDRY BEDROOM # 3 HALL COURT YARD MASTER BEDROOM BEDROOM #1 WALK IN BATH BEDROOM #2 ENTRY TERRACE PANTRY arch (N) 2X FRAMING S LEGEND 3 SMOKE DETECTOR WINDOW SYMBOL detail 4 A.7.1 3 A.7 1 A.7 2 A.7 110 S&P S&P 15 3 4 7 8 9 3 3 6 10 6 4 FAN 35'-0"24'-3"13'-6 1/2"90'-10 1/2"24'-5"7'-11"1'-6" 33'-6"25'-4" 90'-5 1/2"31'-6"45'-10"90'-10 1/2"2 4 6 8 10 11 12 4 109 POWDER 117 GARAGE 108 112 FAMILY ROOM 107 KITCHEN 105 STUDY 103 DINING ROOM 104 102 BATHROOM 117 101 117 S&P S&P 119 120 115 CORRIDOR 115 CORRIDOR 2'-10"8'-0" 10 5POT SHELFPORCH 5/8" TYPE X drywall to create 1 hr. fire rating between garage and habitable space @ walls and ceilingCABCAB arch1 DOOR SYMBOL ELEVATION/SECTION SYMBOL page E.1 A.7 (E) 2X FRAMING MASTER BATHROOM arch soapSHOWER make up f i x e d c o r n e r w i n d o w1'-6"6'-6"STANDARD PARKING SPACE 10'X20' STANDARD PARKING SPACE 10'X20' STANDARD PARKING SPACE 10'X18' 12 4'-0" 111 3'-9"18'-1"8'-0" 4 5 9 AA A.6 BB A.6 CC A.6 DD A.6.1 EE A.6.1 FF A.6.1 GG A.6.2 HH A.6.2 5/8" TYPE X drywall to create 1 hr. fire rating between garage and habitable space @ walls and ceiling 9 1.Contractor to verify all dimensions. 2.Smoke detectors shall sound alarm audible in all sleeping areas, and areas leading to sleeping areas of dwelling unit and be hard-wired and equipped with battery back up and low battery signal. Battery Operated Detectors w/ low battery signal in (E) construction only. 3.Fireblocking shall be installed @: A.concealled spaces of stud walls and partitions, floor and ceiling @ 10'-0" max. intervals both vertically and horizontally. B.Interconnections between vertical and horizontal spaces. C.concealed space between stair stringers at top and bottom run. D.At opening around vents, pipes, ducts, and chimneys(noncombustable materials) E.at openings between attic and chimney chase for factory built chimneys 4.Roofing assembly shall be listed by an approved agency 5.Glazing over 9 sq.ft. having the lowest edge less than 18" above the finish floor and having a top edge greater than 36" above floor, and glazing 5' from top or bottom of stairways with bottom edge less than 60" above floor, shall be tempered. all glazing in doors & enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers edge of glazing is less than 60" above a standing surface or drain inlet. 6.Provide 24" clear space in front of toilet compartment, & 30" clear width. 7.Provide 70 inch high non-absorbent wall adjacent to shower and approved shatter resistant materials for shower enclosure.91.807.1.3, 91.2406.4(5), 91.1115b.9.6,7,8 8.Attic ventilation of 1/150 of the area of ventilated space(approximately 10 sq. in. for each 10 sq. ft. of attic area) is req.sec. 1505.3 9.An approved Seismic gas shutoff valve shall be installed on the fuel gas line on the down stream side of the utility meter and be rigidly connected to the exterior of the building or structure containing the fuel gas piping (per ordinance 171,874-for work over $10,000) 10.Provide ultra flush(1.6 gal.) water closets for all new construction. Existing shower heads and toilets must be adapted. 11.The handgrip portion of handrails shall be not less than 1 1/4" nor more that 2" in circular cross-sectional dimension or shall provide equivalent graspability. Handrail projecting from a wall shall have a space of not less than 1 1/3" between the wall and the handrail. 12.Required windows in sleeping rooms shall have a finish sill height no greater than 44" from finish floor. 13.Fans at bathrooms must provide a min. of 5 air changes per hour, and must vent directly to the outside. Outlet must be min. 36" from closest opening and 36" min. from property line. 14.When mirrored, provide tempered glass @ wardrobe doors. 15.Penetrations through the walls and ceilings separating the dwelling from the garage shall be protected (such as those for vents, pipes, ducts, cables, and wires) with an approved material to resist the free passage of flame and products of combustion. 16.All foam plastic insulation shall have a flame spread index of not more than 75 and a smoke-developed index of not more than 450. 17.Provide 26-min. ga. galvanized weep screed at or below foundation plate line. Weep screed shall be placed a min. of 4" above the earth or 2" above paved areas. Provide cont. sheetmetal flashing where distance of plate line above paved areas is less than 2". See detail sheet A.6. 18.Where hearth at fireplace occurs , all hearth material to be non-combustable. 19.Combustable materials shall not be placed less than 6" from the fireplace opening. 20.Provide landing or floor on each side of each exterior door. The width of the landing shall not be less than the door served extending a min. of 36". Floor elevation of landing at the ext. shall comply with the following: 1.When the egress door swings over the ext. side of the required landing, the floor at the landing shall not be more than 1 1/2" below the top of the threshold. 2.When the egress door does not swing over the exterior side of the required landing, the floor at the landing shall not be more than 7 3/4" below the top of the thresold. 3.Exterior landings shall be permitted to have a slope not to exceed 1/4 unit vertical in 12 units horizontal. 21.Penetrations through walls or ceilings seprating the dwelling from the garage shall be protected (such as those for vents, pipes, ducts, cables, and wires) with an approved material to resist the free passage of flame and products of combustion. PLAN GENERAL NOTES 7 7 30x30 attic access 18" H seat 11 A.8 12 A.8 20"W x 24"H; 6' hdr ht. NOTE:A CREDIT FOR QUALITY INSTALLED INSULATION IS BEING TAKEN WHICH REQUIRES HERS CERTIFICATION PRIOR TO REQUESTING INSULATION INSPECTION FROM BUILDING DEPT. W1 W2 W3 W4 W5 W3 W4 W5 W3 W4 W5 W3 W4 W5 W3 W4 W5 W3W4W5W3 D4 D5 D6D3 D4 D5 D6D3 W8W7 W8W7 W1 W2 W3 W1 W2 W3 D1 D2 D3 D6 D1 D2 D3 W1 W2 W3 SIM. W1 W2 W3 SIM. W1 W2 W3 SIM.W1 W2 W3 SIM.archHALL 14 10 1'-6"4'-2"4'-2" 30x30 attic access10 2'-2" 2'-0" clr. 11 7'-10" 3'-0"3'-0"1'-6" FLOOR PLAN SCALE: 1/4" = 1'-0" 14 14 8/29/12 8:57 AM 4" conc. filled stl bollard A R C H2'-0"clr.6080 slider 2'-0"clr.24" Dia. boxed in column with stucco veneer; typ.1'-6"1'-6"3'-6"6'-0"2'-0"1'-6"FILL IN EXISTING OPENING NEW 34" H PLUMBING WALL; 2X6 STUDS AT 16" OC. PROVIDE ANCHOR @ 32" OC 12'-4"2'-6"2'-3"under count frig under count ice m. 1'-9"2'-6"2'-0"2'-0"2'-6"1'-3" 2 2 EXTEND WALL BAR 6'-8"6'-4"NEW FULL HT. WALL. 2X4 STUDS AT 16" OC. PROVIDE ANCHOR @ 32" OC a l i g nNEW 34" H PLUMBING WALL; 2X6 STUDS AT 16" OC. PROVIDE ANCHOR @ 32" OC face of stud2'-3"17'-3" 30" FR. 30" REF. 5'-0"3'-0"4'-0"3'-0"3'-0"2'-6"3'-0" MICRO/ WRM EXT. GRADE FIXED CABINETRY counter profile counter profile 36" BBQ 2 2 2 BAR FRAME IN (E) OPENING 3'-0"2'-0"3'-6"3'-0"3'-0"2'-6" 2 2 3'-0"1'-4"3'-0"2 22.In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire must be controlled by a vacancy sensor. (CEnC §150.0(k)2I) 23.All interior luminaires required to have light sources compliant with Joint Appendix JA8 must be controlled by either a dimmer or vacancy sensor, except those located in closets less than 70 square feet or hallways. (CEnC §150.0(k)2J) 24.Outdoor lighting permanently mounted to the building must be controlled by one of the following combinations and a manual ON/OFF switch that does not override the chosen combination: (CEC §150.0(k)3) a) Photocell and motion sensor b) Photo control and automatic time switch c) Astronomical time clock d) EMCS with features of an astronomical time clock that does not allow the luminaire to be always ON, and is programmed to automatically turn lighting OFF during daylight hours. 3 3 3'-9"5080PAIR2880 2880 4080 BI PASS3'-0"3'-11" BATHROOM 113 26802680 BI FOLD 1'-0"6'-0" Revillusion® Built-In Firebox electric fireplace RFB42. Install per manu. instructions. 240v hardwired 4 4 4 4 4 4 4 REVISION 1 BRES2021-0158 REVISION 1 - (DELTA 4) MINOR INTERIOR LAYOUT CHANGES. 03/16/2022 DW REF FRE REF MIC GAR 1. revised lighting and per to match revised plan 1-8-22undercab & toe kick undercab & toe kick junc. for clg bm accent lighting elec f/p