BSOL2022-0196 PlansPROJECT DETAILS GENERAL NOTES JURISDICTIONAL NOTES PROJECT INFORMATION STATE,ZIP CODE: CA,92253 AHJ : CITY OF LA QUINTA FINANCE TYPE: NONE SOLAR PERMIT PACKAGE 9.600 kW DC 6.969 kW AC SYSTEM INFORMATION SYSTEM SIZE: 9.600 kW MODULE MODEL: (24) HANWHA Q.PEAK DUO BLK ML-G10+ 400 OPTIMIZER MODEL: NONE INVERTER MODEL: (24) ENPHASE IQ8PLUS-72-2-US BATTERY MODEL: NONE CLIENT INFORMATION NAME: BRIAN MAURER ADDRESS: 79245 KARA CT CITY: LA QUINTA STATE,ZIP: CA 92253 AHJ: CITY OF LA QUINTA • ALL WIRING TO BE BRACED BY PHYSICAL DEVICES DESIGNED AND LISTED FOR THIS USE. • ALL WIRING ON ROOF -TOP SOLAR SYSTEM TO BE PERMANENTLY AFFIXED OFF OF ROOF SURFACE. • CODE VIOLATIONS PRESENT IN INTERCONNECTION PANEL WILL BE CORRECTED UPON INSTALL. • SYSTEM TO BE INSTALLED FOLLOWING APPLICABLE CODES. • RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY POWER. • SOLAR SYSTEM TO BE MOUNTED TO ROOF USING LISTED MOUNTING SYSTEM HARDWARE. BSOL2022-0196 9.6kW SOLAR ARRAY - (24) 400W HANWHA Q.PEAK DUO BLK ML-G10+ PANELS W/ (24) ENPHASE IQ8PLUS-72-2-US MICROINVERTERS + ENPHASE IQ COMBINER 3 BOX [480SF] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE oPTE06/14/2022 BY T)E NAME: BRIAN MAURER ADDRESS : 79245 KARA CT CITY : LA QUINTA 1. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans and accompanying calculations and notify the Engineer of Record of any discrepancies prior to starting construction. 2. These plans are stamped for structural code compliance of the roof framing supporting the proposed PV installation referenced only. These plans are not stamped for water leakage. PV modules, racking, and attachment components must follow manufacturer guidelines and requirements. 3. Please see accompanying Strscoturalpe Calculations and li report for details regarding calculations as well as limits of scope of work and liability. NOTE TO INSTALLERS: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE FOR AT 951.405.1733 IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING: 2x4 TRUSSES @ 24" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 7 FT. CODEINFORMATION LOADING 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA FIRE CODE (CFC)• 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA ENERGY CODE (CEnC) ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TEST LAB. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. • ROOF LIVE LOAD: 20 PSF TYPICAL • GROUND SNOW LOAD: 0 PSF WIND SPEED: 130 MPH • EXPOSURE CATEGORY: C • DEAD LOAD SOLAR PANELS/MOUNTING HARDWARE : 3 PSF • OCCUPANCY TYPE : R-3/U •_ STRUCTURE TYPE : RESIDENTIALV1� • FLOOR AREA : 1478 SQ.FT. • LOT AREA. : 8276 SQ.FT STAMPED 04/2 ,cz pFESS/pH ,��O °OVgS glFy •Z s-y Q 0r^ ly No. C78527 = `Q orCAl\F��� y = REVISIONS REV I DESCRIPTION IDATE I DB I CB SHEET INDEX VICINITY MAP AERIAL MAP SOLAR ARCHITECTURAL DRAWINGS PVA-0 COVER SHEET PVA-1 SITE PLAN SOLAR STRUCTURAL DRAWINGS PVS 1 MOUNTING LAYOUT PVS-2 MOUNTING DETAILS SOLAR ELECTRICAL DRAWINGS PVE-1 ELECTRICAL DIAGRAM PVE-2 ELECTRICAL PLAN PVE-3 ELECTRICAL NOTES PVE-4 LABELING PVE-00 PLACARD CONSTRUCTION HOURS October 1st - April 30 Monday - Friday: 7:00 a.m. to 5:30 p.m. Saturday : 8:00 a-m- to 5:00 p.m. Sunday : None Government Code Holidays: None May isf- September 34th Monday - Friday: 6:00 a.m. to 7:00 p.m. Saturday : 8:00 a.m. to 5:00 p.m. Fred MI Sunday : None Heritage Palms Golf Club, Government Code Holidays: None Construction is NOT PERMITTED in the following Code Holidays: 79245 Kara Cl,La• NewYear'sDay Quinta, CA 92253, USA Miles Ave Dr. Martin Luther King Jr. Day ► President's Day MemoralDay Independence Day - F -La Qt PROJECT LOCATION r Labor Day 1 La Quints X Park Veteran's Day Irger Thanksgiving Day \ Christmas `'iii Tar et The Home Depot9 9 `= ��—_— 4shie1d&Date Gard w sir 1 •+ - — "" , ` ; ' # T } _ - - , ■ • > i �� n� �. 4 • r« . ., ' • .1ti "' • ' ' 9�' S ara Ct,LS CA 922,53' " c". r . r ,_ �, — . USA 1 j PROJECT NO : CSD 0216 DATE DRAWN:04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY :JADE VILLANUEVA INSTALLERS NOTES DESIGNED BY IALTNA ENERGY SERVICES ALTNA ENERGY SERVICES 2168 W GROVE PKWY AMERICAN FORK, UT. 84003 801-735-5123 CALIFORNIA CSLB # 1049108 (855)775-8775 CALIFORNIA STATE ENERGY INC. COMBINE EXISTING BREAKERS TO MAKE ROOM FOR SOLAR BREAKER. - 7. Costco Wholesale Q-t--- 7 / W ' AMe d$ NOT TO SCALE SHEET PVA-0 SITE PLAN LEGEND N (N) COMBINER BOX (N) 60A NON -FUSED AC DISCONNECT (E) MAIN SERVICE PANEL WITH METER# 1B4B-243153 (E) GATE ARRAY 1 - 9.600 kW [x24] (N) MODULES TILT: 18 DEGREES AZIMUTH: 180 DEGREES SITS '' AN SCALE:1/16" = 1'-0" F--- 79245 KARA CT FRONTOF HOME (E) DRIVEWAY N • N CITY OF LA QUINTA BUILDING ENVISION REVIEWED FOR CODE COMPLIANCE DATE06/14/2022 er J)� (E) FENCE (E) POOL E1 BU SW O EV 0 • UTILITY METER MAIN SERVICE PANEL INVERTER WITH INTEGRATED DC DISCONNECT AND AFC! SUB PANEL COMBINER BOX BATTERY BACKUP INTERFACE SMART SWITCH PRODUCTION METER AC DISCONNECT LOAD CENTER EV CHARGER PV MODULES: (PORTRAIT) (LANDSCAPE) EXISTING PV SOLAR FIRE CODE OFFSET RIDGE : 18" I PATH : 36" PROJECT INFORMATION M N < N Z Q 5 Z 000 z oLw 00>- N H W . Z a�Q I- 0 w< � Y a < Z QN-5 . 0 m w cc. • 2o r z Q 0 w C9 <U 0 a � o c w L.o a • ce If) O 6.969 kW AC STAMPED 04/2 \c/vi/ OF CAL -' PLOT LEGEND PROPERTY LINE FENCE LINE DRIVEWAY / ROAD TRENCHING 5) z 0 5) cc 0 0 0 PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA ROOF AREA R324.6.2 - PROVING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA.WHEN THE ARRAYS TAKE LESS THAN 33% WE CAN JUSTIFY AN 18" SETBACK ON BOTH SIDES OF THE RIDGE. WHEN IT TAKES MORE THAN 33% OF THE ROOF AREA WE MUST USE A 3' SETBACK ON BOTH SIDES OF THE RIDGE. TOTAL ROOF AREA: 2265 sqft AREA OF ARRAYS: 41.1" x 74" = 21.1sgft (PER PANEL) 21.1 sqf s„, X 24 panels = 507 sqft (TOTAL PANEL AREA) PERCENTAGE OF TOTAL ROOF AREA: (507 sqft / 2265 sgft)(100)= 22.38% THE PANELS USE 22% OF THE TOTAL ROOF AREA W y SHEET PVA-1 MOUNTING LEGEND • UNIRAC TILE HOOKS ATTACHMENTS 74" RAILS ROOF TRUSSES MODULE: 41.1" i HANWHA Q.PEAK DUO BLK ML-G10+ 400 400 WATTS NOTE: SEE SPEC SHEETS FOR DETAILED INFO ON RACKING AND ATTACHMENT EQUIPMENT. W-TILE RACKING RAIL (TYP.) ROOF ATTACHMENT (TYP.) 48" MAX SPAN 2"X4" TRUSSES, 24" O.C. 5'-10" 34'-5" 3'-8" tt • IRS1I • ttt MOUNT DIAGRAM SCALE: 1/8" = 1'-0" ROOF DETAILS - RS1: TILT: 18 DEGREES AZIMUTH: 180 DEGREES MATERIAL: W-TILE CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ❑ATE06/14/2022 9Y ar 6.969 kW AC PROJECT INFORMATION STAMPED 04/2 w C9 • U < 0 a � o ce o w c.o a of • ce 0 V7 hc(eOV'9 S�,\ lyNo. C78527 -Y_ 9/30/2023 U) z 0 w cc 0 0 PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA w y c000 �Z ▪ Q Z }7 • I- co co mN▪ Lo oz v co Qw SHEET Pvs-1 SEE PVS-1 FOR DIMENSION SEE DATA SHEET w a a MOUNTING TAILS SCALE:NTS mm® TAG DESCRIPTION : 1. ROOF MATERIAL: W-TILE 2. ROOF STRUCTURE: UNDER PURLINS/BRACING 3. ATTACHMENT TYPE: UNIRAC TILE HOOKS 4. MODULE MANUFACTURER: HANWHA 5. MODULE MODEL: Q.PEAK DUO BLK ML-G10+ 400 6. MODULE LENGTH: 74 7. MODULE WIDTH: 41.1 8. MODULE WEIGHT: 48.5 9. MIN. FIRE OFFSET: 18" FROM RIDGE 10. RAFTER SPACING: 24 IN. O.C. 11. RAFTER SIZE: 2"X4" NOMINAL 12. LAG BOLT DIAMETER: 5/16 IN. 13. LAG BOLT EMBEDMENT: 2-1/2 IN. 14. TOTAL # OF ATTACHMENTS: 48 15. TOTAL AREA: 2265 SQ. FT. 16. MAX. HORIZONTAL STANDOFF: 48 IN. 17. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 32 IN. 18. STANDOFF STAGGERING: YES 19. RAIL MANUFACTURER: IRON RIDGE 20. RAIL MODEL: XR10 21. RAIL WEIGHT: 0.436 PLF. 22. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. 23. RAFTER SPAN 1: 7'-0" 24. RAFTER SPAN 2: 7'-0" CITY OF LA QUINTA BUILDING DWISION REVIEWED FOR CODE COMPLIANCE DATE06/14/2022 er V1✓ BILL OF MATERIALS EQUIPMENT DESCRIPTION UNIT QTY ATTACHMENTS UNIRAC TILE HOOKS PIECES 48 RAILS IRON RIDGE XR10 PIECES 12 RAIL SPLICE RAIL SPLICE PIECES 8 MID CLAMPS MID CLAMPS PIECES 40 END CLAMPS END CLAMPS PIECES 16 GROUNDING LUGS GROUNDING LUGS PIECES 4 PROJECT INFORMATION co N < N H crn z W Q z 000 w<z a J OLa 0 0 } arm N F W Loi 0 0 z FIQ H• Qz F 0 CC(2 w< C Q Q 2N Q�� mwg wce.. • } Z Q 0 w C7 Q U U0 Q a H Y • o • o wkl) a • IL Q J 0 U) U Q STAMPED 04/2 0 on DESCRIPTION PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA SHEET PVS-2 THREE LINE DIAGRAM 7 BRANCH # 1 AAA nri ma 12 MODULES PER BRANCH BRANCH # 2 n n n Efri 12 MODULES PER BRANCH ROOFTOP P r° 01 15A,2P 0- r LL J ENVOY CELL MODEM RIER 0A0A,,22P -. 20A,2P IL-6 0 �.1 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 THWN-2 OR OTHER APPROVED WET LOCATION CONDUCTORS REQUIRED AT ALL WET LOCATIONS SYSTEM SUMMARY BRANCH #1 BRANCH #2 INVERTERS PER BRANCH 12 12 MAX AC CURRENT 14.52A 14.52A MAX AC OUTPUT POWER 3,484.8W 3,484.8W ARRAY STC POWER 9,600W ARRAY PTC POWER 9,013W MAX AC CURRENT 29.04A MAX AC POWER 6,969.6W DERATED (CEC) AC POWER 8,743W CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE m106/14/2022 BY BACKFEED CALC. MAX. BREAKER CALC.: 125A X 1.2 - 100A = 50A SOLAR BREAKER LOCATED AT THE FURTHEST END BUS BAR SOLAR OCPD OUTPUT PER MICROINVERTER 290W/240V = 1.21A TOTAL OUTPUT 24 MICROINVERTERS 24*1.21A = 29A CONTINUOUS LOAD RULE 125% 29A*1.25 = 36.30A BREAKER SIZE = 40A TO HOUSE LOADS TO HOUSE LOADS MAIN SERVICE PANEL 125A BUS RATING 120/240V, 10, 3W INCOMING SOURCE FEED (UNDERGROUND) AA A Z'J 120/240V, 10, 3W • • • • • • • • SOLAR OCPD 40A,2P ( I r EQUIPMENT RIGHT OF EQUIPMENT LEFT OF LINE IS (E) EXISTING LINE IS (N) NEW UNLESS OTHERWISE NOTED DESIGN TEMPERATURES ASHRAE EXTREME LOW -8°C, SOURCE: JACQUELINE COCHRAN 33.63°,-116.16° ASHRAE 2% HIGH 44°C , SOURCE: JACQUELINE COCHRAN 33.63°,-116.16° i i r •-EIGND 1 EXISTING GND 3- MCB 100A IMPERIAL IRRIGATION DISTRICT METER NUMBER 1B4B-243153 CONDUCTOR AND CONDUIT SCHEDULE wit LECTRI CAL CALCULATIONS E] STARTING CIRCUIT ENDING CIRCUIT VOLTAGE (VI CONT. CURRENT (Al MAX. CURRENT (12S9G} (All OCPDSIiE NEUTRAL SCE SIZE GROUNDSIZE CONDUCTOR SIZE 75'CAMPACITY }Aj CONDUTOR SIZE CHECK #1 AMBIENT TEMP. CO. TOTAL CC IN RACEWAY 9D°CAMPACITY }A} IA} DERATION FACTOR FOR AMBIENT TEMPERATURE NEC 310.15(B)I2}lal DERATIDN FACTOR FOR CONDUCTORS PER RACEWAY NEC 310.LSIBII3}lal 90°C AMPACITY DERATED (A) CONDUTOR CHECK #Z WIRE LENGTH (FEET) CONDUIT SIZE CONDUIT FILL I% A CIRCUIT 1 JUNC I ON BOX 240 1452 16.15 20 N/A BARE COPPER N6 AWG CU S12 AWG 25 PASS 411 2 30 0117 1 26.1 PASS N/A EM/A A CIRCUIT 2 JUNCtION BOX 240 1452 18.15 20 N/A BARE COPPER 06 AWG CU #12 AWG 25 PASS 44 2 30 0.87 1 261 PASS N/A 4N/A B JUNCTION BOX COMBINER PANEL 1 240 1452 16.15 20 N/A CU RE AWG CU If10 AWG 35 PASS 44 4 40 0$7 as 27.84 PASS SO 3/4" EMT 22.70 C COMRINER PANEL I AC DISCONNECT 240 29.04 36.3 40 CU NB AWG CU #8 AWG CU #8 AWG S0 PASS 44 2 55 O37 1 47.8S PASS 5 3/4' EMT 27A7 D AC DISCONNECT MSP [POI 240 2B-04 36.3 40 CU #8AWG CU #8 AWG CU #8 AWG 50 PASS 44 2 55 037 1 47.85 PASS 5 3/4" EMT 27.47 TAG DESCRIPTION COMPONENT ❑1 (N) SOLAR MODULE (24) HANWHA Q.PEAK DUO BLK ML-G10+ 400 ❑I (N) MICROINVERTER (24) ENPHASE IQ8PLUS-72-2-US ❑2 (N) JUNCTION BOX JUNCTION BOX NEMA 4 ❑3 (N) COMBINER BOX X-IQ-AM1-240-3 (N) AC DISCONNECT 60A NON -FUSED EATON DG222URB ❑5 (E) MAIN SERVICE PANEL 125A MAIN SERVICE PANEL, 100A MAIN CIRCUIT BREAKER MODULES REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING 0 24 Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400W 376.55W 11.14A 10.77A 45.3V 37.13V -0.122V/°K (-0.34%I°K) 20A INVERTERS REF. QTY. MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY ❑ 24 ENPHASE IQ8PLUS-72-2-US (240V) 240V FLOATING 20A 290W 1.21A 15.0A 60V 97.0% PROJECT INFORMATION CO U, N F O) Z a 7 z VOO LLI az o J • W 00> CL u • Lu V U W Z Q -3 a Z �Qu_ W (.9 a 0- H � O CC O W l0 a of 0 6.969 kW AC 8 O 0 DESCRIPTION PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA ory a�<2 onzL 4,t cc cc 0 w z u=¢ SHEET PVE-1 SITE PLAN LEGEND EXTERIOR PV EQUIPMENT [x1] (E) MAIN SERVICE PANEL [x1] (N) 60A NON -FUSED AC DISCONNECT [x1] (N) COMBINER BOX C C• — f — 2 C RS1 - M— f — ■- — f — � ELECTRICAL PLAN SCALE: 1/8" = 1'-0" ROOF DETAILS - RS1: TILT: 18 DEGREES AZIMUTH: 180 DEGREES MATERIAL: W-TILE ❑M SW r JB UTILITY METER MAIN SERVICE PANEL INVERTER WITH INTEGRATED DC DISCONNECT AND AFC! SUB PANEL BATTERY BACKUP INTERFACE SMART SWITCH PRODUCTION METER AC DISCONNECT LOAD CENTER JUNCTION BOX COMBINER BOX EV EV CHARGER ❑ OPTIMIZER / MICRO INVERTER C 0 • PV MODULES: (PORTRAIT) (LANDSCAPE) CONDUIT RUN (ROOFTOP RUN) CONDUIT RUN (UNDER EAVE) CONDUIT RUN (ATTIC RUN) MODULE STRINGING #1 MODULE STRINGING #2 MODULE STRINGING #3 PROJECT INFORMATION M N a C"H z a5z 0 0 0 z oLJi di U0>- arH N H W W U Z a�z H U wa � Y a < a 2 Nz QN-5 ct w wcc 2o H z a U w • U < 0 H � o cc o w L.o a • 0 v7 6.969 kW AC U) 0 U) w ce 0 0 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 06/14/2022 BY jr PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA w y K Y = SHEET PVE-2 NOTES ROOFTOP CONDUCTOR AMPACITIES DESIGNED IN COMPLIANCE WITH ART. 690.8, TABLES 310.15(B)(2)(A), 310.15(B)(3)(A), 310.15(B)(3)(C), 310.15(B)(16), CHAPTER 9 TABLE 4, 5, & 9. LOCATION SPECIFIC TEMPERATURE OBTAINED FROM ASHRAE 2017 DATA TABLES. ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE -SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. OTHER NOTES • DESIGNED ACCORDING TO AND ALL CODE CITATIONS ARE RELEVANT TO THE 2019 CALIFORNIA ELECTRIC CODE. • ALL SPECIFIED EQUIPMENT GROUNDING DEVICES/COMPONENTS MUST BE LISTED FOR USE • INVERTERS ARE EQUIPPED WITH RAPID SHUT DOWN. • 690.11 DC ARCFAULT CIRCUIT PROTECTION. MICRO INVERTERS ARE EXEMPT BECAUSE THERE ARE NO DC STRINGS. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE06/14/2022 6Y 37- BILL OF MATERIALS CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION MODULE HANWHA Q.PEAK DUO BLK ML-G10+ 400 ❑1 24 PIECES 1 HANWHA Q.PEAK DUO BLK ML-G10+ 400, 132 CELLS, MONOCRYSTALLINE SILICON INVERTER ENPHASE IQ8PLUS-72-2-US ❑z 24 PIECES 1 ENPHASE IQ8PLUS-72-2-US MICRO INVERTER AC COMBINER PANEL ENPHASE X-IQ-AM1-240-3 ❑3 1 PIECE 1 ENPHASE IQ COMBINER BOX 3 W/ ENVOY WIRING ENPHASE Q-12-10-240 ❑I 24 PIECES 1 ENPHASE Q CABLE Q-12-10-240 WIRING ENPHASE Q-TERM-R ❑ 1 PIECE 1 ENPHASE Q CABLE TERMINATOR WIRING ENPHASE Q-CONN-10F ❑ 1 PIECE 1 ENPHASE Q-CONN-10F IQ INVERTER FIELD WIREABLE FEMALE CONNECTOR KIT WIRING ENPHASE Q-CONN-10M ❑1 1 PIECE 1 ENPHASE Q-CONN-10M IQ INVERTER FIELD WIREABLE MALE CONNECTOR KIT AC DISCONNECT EATON DG222URB ® 1 PIECE 1 EATON DG222URB, 2-POLE, NON -FUSED, 60A, 240VAC OR EQUIVALENT WIRING GEN-6-AWG-BARE-CU ❑A 72 FEET 1 6 AWG BARE, COPPER (ARRAY GROUNDING/BONDING) WIRING GEN-10-AWG-THWN-2-CU-BLK © 50 FEET 1 10 AWG THWN-2, COPPER, BLACK (LINE 1) WIRING GEN-10-AWG-THWN-2-CU-RD © 50 FEET 1 10 AWG THWN-2, COPPER, RED (LINE 2) WIRING GEN-10-AWG-THWN-2-CU-WH © 50 FEET 1 10 AWG THWN-2, COPPER, WHITE (NEUTRAL) WIRING GEN-8-AWG-THWN-2-CU-BLK ID 0 10 FEET 1 8 AWG THWN-2, COPPER, BLACK (LINE 1) WIRING GEN-8-AWG-THWN-2-CU-RD ©0 10 FEET 1 8 AWG THWN-2, COPPER, RED (LINE 2) WIRING GEN-8-AWG-THWN-2-CU-WH ©0 10 FEET 1 8 AWG THWN-2, COPPER, WHITE (NEUTRAL) WIRING GEN-8-AWG-THWN-2-CU-GR ©©M 60 FEET 1 8 AWG THWN-2, COPPER, GREEN (GROUND) WIREWAY GEN-EMT-0_75DIA ©©E 60 FEET 1 EMT CONDUIT, 0.75 DIA. OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC ❑3 2 PIECES 1 CIRCUIT BREAKER, 20A, 240VAC OCPD GENERIC MANUFACTURER GEN-CB-40A-240VAC ❑s 1 PIECE 1 CIRCUIT BREAKER, 40A, 240VAC OCPD GENERIC MANUFACTURER GEN-CB-15A-240VAC ❑3 1 PIECE 1 CIRCUIT BREAKER, 15A, 240VAC TRANSITION BOX GENERIC GEN-AWB-TB-4-4X ❑z 1 PIECE 1 TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKS PROJECT INFORMATION 6.969 kW AC 8 0 0 DESCRIPTION w PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA SHEET PVE-3 WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATINGS OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXEED AMPACITY OF BUSBAR PER NEC 705.12(B)(3)(3) AC DISCONNECT / BREAKER / POINTS OF CONNECTION WARNING! POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE PER NEC 705.12(B)(3)(2) MAIN SERVICE DISCONNECT WARNING! TURN OFF PHOTOVOLTAIC AC DISCONNECT TO WORKING INSIDE PANEL PER NEC 110.27 (C) BREAKER PANEL/ PULL BOXES/ COMBINER BOX/CIRCUITS/ CONDUITS / EMT ENCLOSURES / MAIN SERVICE DISCONNECTS WARNING! THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT PER NEC 110.27 (C) BREAKER PANEL/ PULL BOXES/ COMBINER BOX/CIRCUITS/ CONDUITS / EMT ENCLOSURES / MAIN SERVICE DISCONNECTS WARNING! DUAL POWER SOURCE SOURCES : UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PER NEC 705.12(D)(3), NEC 705.12(C) & NEC 690.59 PRODUCTION / NET METER (BI-DIRECTIONAL) / MAIN SERVICE DISCONNECT CAUTION! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED PER NEC 705.12(D) & NEC 690.59 MAIN SERVICE DISCONNECT WARNING! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PER NEC 706.15(C)(4) and NEC 690.13(B) BREAKER PANEL / PULL BOXES / COMBINER BOX / CIRCUITS / CONDUITS / EMT ENCLOSURES / MAIN SERVICE DISCONNECTS / AC DISCONNECT / BREAKER / POINTS OF CONNECTION PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT : 29.04 AMPS AC NOMINAL OPERATING VOLTAGE : 240 VOLTS PER NEC 690.54 & CEC 690.13 (B) INVERTER / BREAKER PANEL / PULL BOXES / AC DISCONNECT / BREAKER / POINTS OF CONNECTION SOLAR PV DC CONDUIT PER NEC 690.31 (0)(2) EMT/ CONDUIT RACEWAYS WARNING : PHOTOVOLTAIC POWER SOURCE PER NEC 690.31(D)(2) EMT/ CONDUIT RACEWAYS MAIN PHOTOVOLTAIC SYSTEM DISCONNECT PER NEC 690.13(B) MAIN SERVICE DISCONNECT / UTILITY METER RAPID SHUTDOWN FOR SOLAR PV SYSTEM PER NEC 690.56(C)(2) & CEC 690.56(C)(3) RAPID SHUTDOWN DEVICE DO NOT DISCONNECT UNDER LOAD PER NEC 690.15(B) & NEC 690.33 (D)(2) MAIN SERVICE DISCONNECT WARNING! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE WHENEVER THEY ARE EXPOSED TO SUNLIGHT PER NEC 690.13(B) DC DISCONNECT / BREAKER / RECOMBINER BOX SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY OLAR ELERRIC P IELEClS PHOTOVOLTAIC AC DISCONNECT PER NEC 690.13 (B) AC DISCONNECT / BREAKER / COMBINER BOX PHOTOVOLTAIC DC DISCONNECT PER NEC 690.13 (B) DC DISCONNECT / BREAKER / COMBINER BOX CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 06/14/2022 gy �i- MAXU M I M DC VOLTAGE OF PV SYSTEM PER NEC 690.53 DC DISCONNECT / BREAKER / COMBINER BOX NOMINAL OPERATING AC VOLTAGE : 240 V NOMINAL OPERATING AC FREQUENCY: 60 Hz MAXIMUM AC POWER: 240 VA MAXIMUM AC CURRENT:29•04A MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION CIRCUIT: 40A PER NEC 690.52 LABELING LETTERING TO BE 3/8" WHITE ON RED BACKGROUND UV RESISTANT STICKERS. PROJECT INFORMATION CO N < CH Z a5z 0 0 0 LL Q Z O di Li 00>- arH N H W W U Z aQ Z H 0 WQ � Y a tea N Z QN- 5 0 m W J W CC 20t Z < 6.969 kW AC Z 0 LU w cc 0 0 PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA SHEET PVE-4 CAUTION POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: SOLAR PHOTOVOLTAIC ARRAY ON ROOFTOP SERVICE POINT AC DISCONNECT COMBINER BOX CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE Din 06/14/2022 6Y� co Q N F Z W Q 5 Z U00 w<z O LL di U0 } LL I-UJ N U W Z Q Q Z Q LL 0 < o o o to t0 01 o; E0 U, 0 U, cc PROJECT NO : CSD 0216 DATE DRAWN: 04.15.2022 DRAWN BY : MARY GRACE RAMOS DATE CHECKED : 04.15.2022 CHECKED BY : JADE VILLANUEVA Q w o 4 SHEET ory v,^oZ O Z yx cc cc 0 11 J LL Z co Q co PVE-00 PRO SERIES SOLARHOOKS :!UNIRAC BETTER SOLAR STARTS HERE UNIRAC Pro Series SOLARHOOKS is a complete line of attachment solutions for tile roofs. Featuring UNIRAC's exclusive POWERARCH technology which increases strength by up 60% more than traditional tile hooks, SOLARHOOKS are simple to install and designed for maximum convenience. Available in universal designs and in specific shapes for flat, S and W tiles, SOLARHOOKS are kitted with stainless lag bolts and have a bead blasted stainless steel finish. With SOLARHOOKS, you have everything you need for a quick, professional installation. UP TO 60% STRONGER Exclusive POWERARCH technology ensures no array rattling or broken tiles during high winds. SIMPLE AND VERSATILE Multiple hole patterns and slotted connections provide *stability, Stainless steel lag bolts bring longterm peace of mind. EXTENSIVE ASSORTMENT Available in a variety of universal, flat tile & Spanish tile designs to handle any challenge. THE COMPLETE TILE ROOF SOLUTION I111111'I11I111114111'111'll'111'141111111IIIIlIIIIIIIII IIIIIIIIIllill111U11111111111111111111111III IIII Ilil11111'111 ill'III III IIIIIII111'IIIIiIIIIII{1'11'I11111F'1L1lli lilt Ili I1IIIli IIII itllli111lllll1lIIlI141111111111,11111 Illlll11.11illi1l III11l' III llll il111111,IIIIIa1111111411.1111'J11111'll" 11111I 1111I1111111111141111 Ili III! II111111111,11ill IIII1I' Ili 'u cecc BETTER SOLAR STARTS HERE ElIi1;1114/ 14, 1 APPLICATION GUIDE x =x= �dc Ocnc7 ees L o Bead Blasted 304 Stainless Steel Best in low — med wind I snow regions °a Wr l ) • } ] III CC- 1.6.� � alo o tix W co M W ILN7 4.� ~ ex cc M Q aim2 1 c S T N + , PI Pr aVJ e. a C W �n-c GI = o o Bead Blasted 304 Stainless Steel Best in low — med wind / snow regions Yes ix ) } } ) ] w 4 r Y C 4 S .. . CC o .rcn G7 E. Cam} aFki A ---.wr di c in- LE r -1> } } . x ©; x ..J az . G7 c mr 1dcr7 Best in low — med wind 1 snow regions 1 N }1 > } S . MODEL PART NUMBER MATERIAL z Pc USES EXISTING TILES LIEU . OR RAIL -LESS DIRECT MOUNT, HO L-FQDT REQUIRED FLAT TILE $ TILE LY r UNIVERSAL TILE 0 1 - Z NO TEE MOD. REQUIRED a c I LrJ Lin 417 Li - FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 IRONRIDGE Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested Ail components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Integrated Grounding UL 2703 system eliminates separate module grounding components. PE Certified Pre -stamped engineering letters available in most states. Design Software Online tool generates a complete bill of materials in minutes. 20 Year Warranty Twice the protection offered by competitors. See Description I Length Rd Section Properties _ Property Value Total Cross -Sectional Area 0.363 in2 Section Modulus (X-Qxa1 0.136113 Moment of Inertia (X-misl 0,124 hi Moment of Inertia (Y-ads] 0,0321n4 Torsional Constant 0.076 ina Polar Moment of Inertia 0.033 in4 Cut Sheet 1 Clear Part Number Black Part Number Description I Length Material Weight XR-10-132A XR-10-132B XR10, Rail 132" (1 l Feet) 600a$e s Aluminum 4.67 bs. XR-10-168A XR-10-168B XR10, Rail 168" (14 Feet) 5.95 bs. XR-10-204A XR-10-204B XR10, Rail204" (17 Feet) 7.22 bs. DUOfa Q.PEAK DUO BLK ML-G1O+ 385-405 ENDURING HIGH PERFORMANCE THE IDEAL SOLUTION FOR: Rooftop arrays on resldentiel bulktings Engineered in Germany E!den R ESE ARCH TOP BAANDAV Warranty BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%, 401 CELLS Yleld Securlly THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer 10 peas the most Comprehen- sive quality programme in the industry; The new -Quality Controlled Pe of the independent cerlificatlori institute TOY Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior_ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PIE) Technologyl, Hot -Spot Protect and Traceable Quality Tra.Qm. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INV ESTM ENT Inclusive 25-year product warranty end 25-year linear performance warranty2, 'APT test conditions according to I EC/TS e2804-1:2016, method A (1500V. 9Bhl ' See data a heel on rear for furllear information. QCELLS MECHANICAL SPECIFICATION Format 74.01n x 41.1in x 1.261n (including frame} (1879mm x 1045mm x 32mm) Weight 48.5lbs (22.0kg) Front Cover 013 in (3,2 corn) thermally pre -stressed glass with anti -reflection technology Beck Cover Composite film Frame Black anodized aluminum Call 8 x 22 mcnocrystallIne O.ANTUM solar half cells Junction Box 2.09-3.98inx1.26-2.36in x0.59-0.71in (53-101mm x 32-60MM x 15-16mm), IP61 with bypass diodes Cable 4 mrrls Solar cable; {+j a 49.21n (1250mm), (-)>49.21n {1250 mm) Connector StAubli MC4; IP68 T O. amen.. 42N rl9iiwM 156'1206.6 mm1 .a.r ux6mNl c r a r band q Ethra Jr N.! mml soar l}2W lrrnl ▪ i.Nw.J¢.elsOLTALAI cat sir iserr.a is [who,* nab. dl rwwrA<A raw for•d aavmrsrnu I 7III a-' .w ELECTRICAL CHARACTERISTICS POWER CLASS 88S 390 SOS 409 406 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +6 W J -9 IN) E Power at MPP' P,Wp IWl 388 390 395 400 405 Short Circuit Currant, - [A] 11.04 11.07 11.10 11.14 11.17 Open Circuit Voltage' Ve,c [VI 45.19 45.23 45.27 45.30 45.34 Current at MPP Voltage at MPF INpp [A] 10.59 V,.Fr €vl Se 20 lass 38.02 10.71 36.86 10.77 37,13 10,83 37.39 Efficiency, Il [ ] z 18.6 a 19.9 a2E1 a20.4 a 20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT' Power et MPP Few lwl 2a8.a 292.8 206.3 300.1 303.8 E shall Circuit Current Opel' Olr0vft Voltage N Currant at MPP Va Nen [A] M [A] 8-90 42.62 B.35 892 42.6E 8.41 13,9E 4269 B.46 8,97 4272 8.51 9.00 4276 B.57 Voltage at MPP V„. M 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances P,a t 3 %; ram; Voc t5 % at STC:1000 WJm', 25±2 "C, AM 1.5 according W ISO 60904-3 •'600 W/m', NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE �Ee6 II ® 1° V t7 - 5c5I.. - rWn'q,µ[br.rn.rN� At least 9B%of rrprnlnel power during fire! year. Thereafter mak 0.5% degradation per year. At least 93.8% of nominal power up Lola years. At least 8a%of nominal power veto 25 years. All date within maaaxemant toleranc- es. Full warranties inaccordance with the warranty terms of the C CELLS sales organisation of your respective •r ▪ Jr a Country. wm�a wrammrcitercaoniceper,nJmCda iL xa: YEARS ua 1 r r I I I NM L L I II I M ---F r----------I 1 we wo �60 we WIC weaImAriCatrriljr&J Typical module performance under low irradiance ceedltieaa in comparison to STC condNars (25°C.1000Wjm') TEMPERATURE COEFFICIENTS Temperature Coeffictard of I� u I961K] +0.04 Temperature CaefficlerltofV� 15E41{] -027 Temperature Coeffleteel of Pup, yr (91.IK] -0,34 NomInalModule Operating Temperature NMOT (°F] 109e6A(43±3°Cy PROPERTIES FOR SYSTEM DESIGN Maximum Syatern Voltage Vrra IV) Maximum Serie! Foes Rating IA DC] 1000 (IEC)I1000 (UUL) PV module clessif[oetion 20 Furl Baling based on ANSI /UL61730 Class II TYPE 2 Max. Dedgo Load, Push ►PuIP [Ibsjft'] Max. Teat Load, Push/ PuIP [Ibs/ft'] 'Sae Installation Manual 75 [3500 Pa) / 55 (2e60 Pe} Permitted Module Temperetere 113 (6400Pa)184 (4000Pa) en Continuous Duty -40'F up to +188°F (-40°C up to +66°C) QUALEFICATIONS AND CERTIFICATES PACKAGING INFORMATION 1.11_ 01730, C€complain. O ill Carwcaed PV - TOVRheiNen4, IEC 612162011, IEC 8173021716, U.S. Primal No. 9,093,216(solar cells& 8CPV Carvhcanoe cr9Or5. 6:11 C G US u�evau CE raea,.w.e mm.,b. a 1111 curia icoi Ib 0-O Horizontal 76.4in 43.3in packaging 1940mm 1100mm 45.0in 1220 min 1656 lbs 751kg 24 pallets 24 32 pallets modules Not.: Installation Instructions must be Followed_ See the installation and operating manual cr contact our technical service department for further Intarmation on approved retaliation and usecf this prOduet. Hanwha Q CELLS America 1no, 4130 Spectrum Center Drive. Suite 1400, Irvine, CA 92815, USA I TEL+1948 748 59 95I EMAIL inquiyeus,q-celrs,com I WEBwww,q-cells.us 8 A O a I 8 e a U U I ENPHASE MEM 108 Series Microinverters KM Series Microinverters Our newest 108 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, 108 Series Microinverters integrate with the Enphase l0 Battery, Enphase I4 teteway, and the Enphase App monitoring and analysis Software. Connect PV modules quickly and easily to 106 Series Microinverters using the included 0-DCC-2 adapter cable with plug-n-play MC4 connectors. Enphase 25 year limped wa rrarWi 108 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. 108 Series Microinverters are IA Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufaoturer'sinstructions. C 2021 Enphase Energy. Atl rights resiarved. Enphase, the Enphase logo, 10.8 mlcrolnverters, and other names are trademarks of Enphase Energy. Inc. Data subject to change. 108St fly-c0o1-01-EN-l)5-2021-10-19 Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21 (UL 1741-SA) requirements INPUT DATA lDt1 100-6D-2-US IDBPLUS-72-2-US 108H-72-2-US MIA -72-2-US 108H-2-0-72-2-US 10B11-208-72-2-1.1S' Commonly used module pairings' Module compatibility MPPT voltage range ✓ 235--350 60-ce11/12O half -cell ✓ 27 - 37 25-48 ✓ 30/48 Operating range V Min/max start voltage Max input DC voltage Max DC current''module Esc' Overvoltage class DC port DC port backfeed current PV array configuration ✓ 50 A mA 235 - 440 260-460 295 - 500 320--540• 295-•500r 60-cell /120 half -cell and 72-cell/144 half -cell 29-45 33-45 36-45 36-45 38-45 25- .58 30 / 56 60 15 II 0 ix1 Ungrounded array: No additional DC side protection required: AC side protection requires max 20A per branch circuit output BAIAIACO I08-60-2-US IDBPWS-72-2-US 168n-72-2-US 10.8A-72-2-us OBH-tad-72-2-uS IDBH-20a•72i-2-us Peak output power Max continuous output power Nominal (L-L) voltage/re nge Max continuous output current Nominal frequency Extended frequency range Max units per 20 A (L-L) branch Circuits Total harmonic distortion Overvoltage class AC port AC port backfeed current Power Factor setting Grid -tied power factor {adjustable) Peak efficiency CEC weighted efficiency Night-time power consumption VA H; Hx mA 24j 2a0 500 290 1.0 1.21 16 13 330 325 240/211-264 1.35 366 349 1.45 60 50-68 11 11 384 380 1.58 10 366 360 208 / 183 - 250 1.73 9 <5% III 30 1.0 0.85 leading - 0,851agging • 97.5 mW 97 97.6 97 97.6 97 60 97.6 97.5 97.6 97 97.4 97 MECHANICAL DATA Ambient temperature range Relative humidity range DC Connector type Dimensions (Hxwxo) Weight Cooling Approved for wet locations Acoustic noise at 1 in Pollution degree Enclosure Environ. category / 'UV exposure rating -40°C to •60°C (-40°F to •140°F) 4% to 100% (condensing) MC4 212 mm (8.3-) x 175 mm (6.91 x 30-2 mm 0-21 1.08 kg {2.38 Ibs) Natural convection - no fans Yes <60 dBA P03 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA). UL 62109-1. UL1741/IEEE1547. FCC Part 15 Class B. ICES-0003 Class B. CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64.218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. {t} Tite lQBt1-208 variant will be operating In grid -tied mode only at 28BY AC. (2) No enforced DC/AC ratio. See the cornpatibllity calculator at httgs://link,anphase,com/module-compatibility {31. Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal it required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 108 SE-DS-0 001-01-EN-U S-2021-10-19 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) The Enphase IQ Combiner 3' with Enphase IQ Envoy"consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly_ Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-A, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • BO A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty UL listed USTED To learn more about Enphase offerings, visit e_nphase.cnrn ENPHASE. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-I Q-AM 1-240-3 ACCESSORIES and REPLACEMENT PARTS (not IQ Combiner 3 with Enphase IQ Envoy' printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0, 5%) and optional* consumption monitoring (+/- 2.5%). included, order separately) Enphase Mobile Connect" CELLMODEM-03 (4G/12-year data plan) CELLMODEM-01 (3G/5-year data plan) CELLMODEM•M1 (4G based LTE-Mf 5-year data plan) Consumption Monitoring* CT CT-200-SPLIT • Consumption monitoring Is required for Enphase Storage Systems Wireless USB adapter COMMS•KIT-01 Circuit Breakers BRK-10A-2-240 BRK-15A-2-240 BRK-20A-2P-240 EPLC-01 XA-PLUG-120-3 XA-ENV-PCBA•3 Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US. Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Split core current transformers enable whole home consumption metering (+/- 2.5%)- Installed at the IQ Envoy. For communications with Enphase Encharge'" storage and Enphase Enpower" smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner' and allows redundant wireless communication with Encharge and Enpower. Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Power line carrier (communication bridge pair), quantity - one pair Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating System voltage Eaton BR series busbar rating Max. continuous current rating (output to grid) Max. fuse/circuit rating (output) Branch circuits (solar and/or storage) Max. continuous current rating (input from PV) Max. total branch circuit breaker rating (input) Production Metering CT Continuous duty 120/240 VAC, 60 Hz 125 A 65A 90 A Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) 64 A 80A of distributed generation / g0A with IQ Envoy breaker included 200 A solid core pre -installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) Weight Ambient temperature range Cooling Enclosure environmental rating Wire sizes Altitude 49.5 x 37-5 x 16.8 cm (19.5" x 14.75' x 6.63"). Height is 21.06" (53.5 Cm with mounting brackets). 7-5 kg (16.5 Ibs) -40° C to +46° C (-40° to 115° F) Natural convection, plus heat shield Outdoor, NRTL•certified, NEMA type 3R, polycarbonate construction • 20 A to 50 A breaker inputs. 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi Ethernet 802.11 b/g/n Optional. B02.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance, Combiner Compliance, IQ Envoy UL 1741, CAN/CSA C22.2 No. 1071,47 CFR, Part 15, Class B, ICES 003 Production metering. ANSI C12.20 accuracy class 0-5 (PV production) UL 60601-1/CANCSA 22,2 No. 61010-1 To learn more about Enphase offerings, visit enphase.com 0 2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, 10 Combiner 3, and other trademarks or service names are the trademarks of Enphase Energy, Inc. 2019-i 1-04 ENPHASE. FAIT•N Powering Business Worldwide Eaton general duty non -fusible safety switch DG222URB U PC:782113144238 Dimensions: • Height: 14,38 IN • Length: 7.38 IN • Width: 8.69 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: Non -fusible, single -throw - Amperage Rating: 60A • Enclosure: NEMA 3R, Rainproof • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non -fusible • Number Of Poles: Two -pole - Number Of Wires: Two -wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG222URB Certifications: • UL Listed Product compliance: No Data pe.eaton.com