Loading...
BSOL2023-0020BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 01/19/2023 ISSUED DATE: 03/14/2023 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar 54895 ARISTIDES CT BSOL2023-0020 767790022 $30,000.00 Owner:Michael S. Hildreth 54895 Aristides Ct, La Quinta, CA 92253 Applicant:HOT PURPLE INC DBA HOT PURPLE ENERGY P O BOX 261, PALM SPRINGS, CA 92263 Contractor:HOT PURPLE INC DBA HOT PURPLE ENERGY / 940550 P O BOX 261, PALM SPRINGS, CA 92263 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 10/10/24 10:36 am Page 1 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2023-0020 54895 ARISTIDES CT BUILDING PERMIT construction lender preliminary notice from that duty. Printed: 10/10/24 10:36 am Page 2 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2023-0020 54895 ARISTIDES CT BUILDING PERMIT HILDRETH / 8KW PV SOLAR SYSTEM, (20) MOD, TESLA BATTERY *** 8kW SOLAR ARRAY W/ 27kWh STORAGE BATTERY SYSTEM - (20) 400W TESLA T400H PANELS W/ (1) TESLA POWERWALL 2+ INVERTER W/ INTEGRATED BATTERY, (1) POWERWALL 2, BACKUP GATEWAY 2 W/ INTERNAL PANELBOARD & NEW 100A CRITICAL LOADS PANEL [420SF] 2022 CALIFORNIA BUILDING CODES. Use of Permit Construction Details 8System Size (kW DC)2PV Strings (EA) Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BSOL2023-002 0 $2.00 BSAS SB1473 FEE $2.00 $110.88 PERMIT ISSUANCE $110.88 $8.00 TECHNOLOGY ENHANCEMENT FEE $8.00 $11.00 RECORDS MANAGEMENT FEE $11.00 $29.18 PV SYSTEM LESS THAN 10KW PC $29.18 $29.18 PV SYSTEM LESS THAN 10KW $29.18 $190.24 $190.24 Total for Invoice PERMIT-BSOL2023-0020 Grand Total for Permit $190.24 $190.24 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 01/19/2023 0:00 SOLAR FINAL** v.1 Inspection ROUGH ELEC v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections Printed: 10/10/24 10:36 am Page 3 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2023-0020 54895 ARISTIDES CT BUILDING PERMIT A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 10/10/24 10:36 am Page 4 of 4 PERMIT INSPECTION HISTORY REPORT (BSOL2023-0020) FOR CITY OF LA QUINTA Solar 01/19/2023Application Date:Permit Type:767790022Parcel Solar 03/14/2023Work Class:Issue Date:54895 ARISTIDES CT LA QUINTA, CA 92253 Address: Finaled Expiration Date:Status:Description:HILDRETH / 8KW PV SOLAR SYSTEM, (20) MOD, TESLA BATTERY *** 8kW SOLAR ARRAY W/ 27kWh STORAGE BATTERY SYSTEM - (20) 400W TESLA T400H PANELS W/ (1) TESLA POWERWALL 2+ INVERTER W/ INTEGRATED BATTERY, (1) POWERWALL 2, BACKUP GATEWAY 2 W/ INTERNAL PANELBOARD & NEW 100A CRITICAL LOADS PANEL [420SF] 2022 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:Michael S. Hildreth HOT PURPLE INC DBA HOT PURPLE ENERGYHOT PURPLE INC DBA HOT PURPLE ENERGY Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 03/24/2023 Rough Electrical ECON:2303220323 47094 Approved Mark Hunt No Complete Comments: Griffin Ranch Community / Manned Gate NOTES Created By TEXT Created Date System Administrator 3/22/2023 3:23 PM HOT PURPLE INC DBA HOT PURPLE ENERGY Contact Name: HOT PURPLE INC DBA HOT PURPLE ENERGY Site Address: 54895 ARISTIDES CT Phone: 7608983939 e-Mail: angela@hotpurpleenergy.com 03/22/2023 Mark Hunt WIRE SIZES ARE CORRECT WITH STICKERS EVERY 10' 03/24/2023 03/31/2023 Solar Final ECON:2303290551 31141 Approved Mark Hunt No Complete Comments: Griffin Ranch Estates NOTES Created By TEXT Created Date System Administrator 3/29/2023 5:51 PM HOT PURPLE INC DBA HOT PURPLE ENERGY Manned Gate Contact Name: HOT PURPLE INC DBA HOT PURPLE ENERGY Site Address: 54895 ARISTIDES CT Phone: 7608983939 e-Mail: angela@hotpurpleenergy.com 03/29/2023 78-495 Calle Tampico Page 1 of 1October 10, 2024 H o t P u r p l e E n e r g y H PSheet Number:Job Number:Title:Checked by:Date:Scale:Revisions:Date:Drawn by:810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com INTEGRATOR:Michael Rango760.322.4433 Lic. No. 940550Hildreth Residence 2213554895 Aristides Ct La Quinta, CA 922539/8/2022SFMJRSheetMichael RangoPV-0.0COVER SHEETNTS DESCRIPTION OF WORK:ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION FLUSH MOUNTED @ 18°FACING AN AZIMUTH OF 270° CONSISTING OF (20) TESLA T400H 400 WATT MODULES (8Kw) ANDA TESLA BATTERY BACKUP SYSTEM.RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND PEGASUSSOLAR MOUNTS.INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES:CEC 2022 - ARTICLE 690, 705,706 AND OTHERSCPC 2022CBC 2022CMC 2022CFC 2022CRC 2022LA QUINTA MUNICIPAL CODEDRAWING SHEETS:COVER SHEET PV-0.0OPTIMIZER STRINGING NOTES (NOT FOR PERMITTING)PV-0.0 (2)SITE PLANPV-1.0SYSTEM PERFORMANCE NOTES (NOT FOR PERMITTING)PV-1.0 (2)ROOF PLANPV-2.0SINGLE LINE DIAGRAMPV-3.0MOUNTING DETAILPV-4.0WARNING LABELINGPV-5.0SPECIFICATION SHEETS:TESLA T400H MODULETESLA POWERWALL PLUS & TESLA 7600 INVERTERTESLA GATEWAY - UL1741 PCSHD6135FB HEAT DETECTOR SPEC SHEETUNIRAC CERTIFICATIONRev B 1/20/23GENERAL NOTES:1.ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDERTHE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN.2.ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SACERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVEDFOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEETAPPROPRIATE NEMA STANDARDS.3.THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDINGPROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAICSYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION.4.PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCALAUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER.5.THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEADLOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ONTHE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THEPHOTOVOLTAIC SYSTEM OR INSTALLATION.6.ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS.7.ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE INACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS.8.TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTUREThis item has been digitallysigned and sealed on03/09/20238kW SOLAR ARRAY W/ 27kWhSTORAGE BATTERY SYSTEM- (20) 400W TESLA T400HPANELS W/ (1) TESLAPOWERWALL 2+ INVERTERW/ INTEGRATED BATTERY, (1)POWERWALL 2, BACKUPGATEWAY 2 W/ INTERNALPANELBOARD & NEW 100ACRITICAL LOADS PANEL[420SF] 2022 CALIFORNIABUILDING CODES.03/14/2023Deisy MendezBSOL2023-0020 1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING)Panel S/N:03/14/2023Deisy MendezBSOL2023-0020 ARISTIDES CT H o t P u r p l e E n e r g y H PSheet Number:Job Number:Title:Checked by:Date:Scale:Revisions:Date:Drawn by:810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com INTEGRATOR:Michael Rango760.322.4433 Lic. No. 940550Hildreth Residence 2213554895 Aristides Ct La Quinta, CA 922539/8/2022SFMJRSheetMichael RangoPV-1.0SITE PLAN1" = 15'For Photovoltaic arrays occupying not more than 33 percent of the plan viewtotal roof area, not less than 18" clear set back is required on both sides of ahorizontal ridge. For Photovoltaic arrays occupying more than 33 percent ofthe plan view total roof area, not less than 36" clear set back is required onboth sides of a horizontal ridge. CRC R324.6.2Not less than two minimum 36" wide pathways on separate roof planes, fromlowest roof edge to ridge, shall be provided on all buildings. At least onepathway shall be provided on the street or driveway side of the roof. CRCR324.6.1Designation of ridge, hip, and valley does not apply to roofs with 2-in-12 orless pitch.Total sq ft = 7,769Solar sq ft = 420 (5.4%)SITE PLAN KEYNOTE:EXISTING ELECTRICAL1.1 400A MAIN ELECTRICAL PANEL1.2SUBPANELNEW ELECTRICAL(ADJACENT TO MSP)2.1 SYSTEM AC DISCONNECT2.2ESS SAFETY DISCONNECT NEW ELECTRICAL(INSIDE GARAGE)2.3TESLA GATEWAY/GENERATION PANEL2.4TESLA POWERWALL PLUS2.5TESLA POWERWALL 2 AC2.6BU CRITICAL LOADS PANEL2.7HEAT DETECTORSITE LEGEND FIRE EASEMENT/ACCESSEAVE SETBACK/WALLWORKING CLEARANCES SHALL BE PROVIDEDAROUND ALL EQUIPMENT PER CEC 110.26Rev C 03/09/23SPECIAL NOTE FOR ESS SYSTEMS:`1206.11.6 OF THE CALIFORNIA STATE AMENDMENTS STATES THAT A SMOKE ALARM OR HEATALARM SHALL BE INSTALLED IN THE VICINITY OF THE BATTERY SYSTEM. (HEAT ALARMS SHALLBE USED WHERE SMOKE ALARMS CANNOT BE USED BASED ON THEIR LISTING - INSIDE AGARAGE.) HEAT ALARMS SHALL BE INTERCONNECTED WITH THE HOME SMOKE ALARM.1206.11.2.1 INDIVIDUAL ESS UNITS WHEN INSTALLED SHALL BE SPACED 3' FROM EACHOTHER.1206.4.5 WHERE ESS ARE SUBJECT TO IMPACT BY A MOTOR VEHICLE IMPACT PROTECTIONSHALL BE PROVIDED BY THE INSTALLATION OF SAFETY BOLLARDS IN FRONT OF ESS.This item has been digitallysigned and sealed on03/09/202303/14/2023Deisy MendezBSOL2023-0020 SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING)CREW NOTES:INVERTER M/NINVERTER S/NSTRING CONFIG(1 column each MPPT)INPUT #12AZIMUTH/ORIENTATIONSLOPE/TILTVOC @ JboxVOC @ InverterV+ to GndV- to GndAC L1-L2AC L1-NAC L2-NAC POWERWATTS @TIME OF DAYAMBIENT TEMP.WEATHERSUNNYPARTLY CLOUDYCLOUDYINVERTER M/NINVERTER S/NSTRING CONFIG(1 column each MPPT)INPUT #12AZIMUTH/ORIENTATIONSLOPE/TILTVOC @ JboxVOC @ InverterV+ to GndV- to GndAC L1-L2AC L1-NAC L2-NAC POWERWATTS @TIME OF DAYAMBIENT TEMP.WEATHERSUNNYPARTLY CLOUDYCLOUDYINVERTER M/NINVERTER S/NSTRING CONFIG(1 column each MPPT)INPUT #12AZIMUTH/ORIENTATIONSLOPE/TILTVOC @ JboxVOC @ InverterV+ to GndV- to GndAC L1-L2AC L1-NAC L2-NAC POWERWATTS @TIME OF DAYAMBIENT TEMP.WEATHERSUNNYPARTLY CLOUDYCLOUDYSTRING CONFIG(1 column each MPPT)STRING CONFIG(1 column each MPPT)STRING CONFIG(1 column each MPPT)STRING CONFIG(1 column each MPPT)STRING CONFIG(1 column each MPPT)STRING CONFIG(1 column each MPPT)03/14/2023Deisy MendezBSOL2023-0020 H o t P u r p l e E n e r g y H PSheet Number:Job Number:Title:Checked by:Date:Scale:Revisions:Date:Drawn by:810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com INTEGRATOR:Michael Rango760.322.4433 Lic. No. 940550Hildreth Residence 2213554895 Aristides Ct La Quinta, CA 922539/8/2022SFMJRSheetMichael RangoPV-2.0ROOF PLAN1" = 5'MOUNT PLAN KEYNOTE:RACK MOUNT COMPONENTS1.1UNIRAC ALUMINUM SUPPORT RAIL1.2PEGASUS TILE REPLACEMENT MOUNTSSTRUCTURAL2.1ROOF SUPPORTS 2x4 ENGINEERED TRUSS(24" O.C.)1.VERIFY RAFTER SPACING IN THE FIELD BEFOREATTACHING MOUNTS ROOF.2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OFRAFTERS AND MAKE STRUCTURAL CONNECTION TOTHE RAFTERS.3.STRUCTURAL CONNECTION TO ENGINEERED TRUSSSHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAGSCREWS 3" MIN. EMBEDMENT.4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS.5.PHOTOVOLTAIC MODULES SHALL HAVE 1.9 MOUNTS(LAG SCREWS) PER PANEL.6.(E) ROOF STRUCTURE IS 18 DEGREE 2X4 ENGINEEREDTRUSS 24" O.C TYP.7.(E) ROOFING MATERIAL IS 1 LAYER OF CONCRETECURVED TILE OVER 1 LAYER OF 30LB. FELT PAPER AND1/2" OSB PLYWOOD DECKING.8.MODULE DIMENSIONS 74.4" x 41.2"48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6'NO ROOF VENTS, ATTIC VENTS OR OTHER NECESSARY BUILDING COMPONENTSMAY BE COVERED OR ALTERED BY THE INSTALLATION OF THE NEW PV ARRAYRev B 1/20/23This item has been digitallysigned and sealed on03/09/202303/14/2023Deisy MendezBSOL2023-0020 MID CIRCUIT INTERRUPTERPOWERWALL+ PV RSDUL 1741 PVRSE UL 3741NOM. INPUT CURRENT 12AMAX. INPUT ISC 15A1850000-xx-yTESLA POWERWALL +GRID-TIE PV/BATTERY INVERTERPV INPUT: 60 TO 550 VDCOUTPUT: 7600 WATTS GRIDOUTPUT: 9600 WATTS BACKUPROUND TRIP EFFICIENCY: 90%240 VAC, 32 AMPS MAX GRIDMAX CONTINUOUS 40A BACKUPINTEGRATED GFCI ANDDC DISCONNECTSAC OUTTESLA POWERWALL 2+USABLE ENERGY 13.5kwhMAX OUTPUT 5kWPOWER FACTOR +/- 0.85240V/24AAC OUTDTESLA POWERWALL 2USABLE ENERGY 13.5kwhMAX OUTPUT 5kWPOWER FACTOR +/- 0.85240V/24ATPN # 1092170-xx-x(N)BU CRITICAL LOADS PANEL125A BUSS,120/240V, 1PH, 3WE100A BREAKERESSMETER+-TESLAGATEWAY 2TPN #1232100-xx xPCSN.C. CONTACT(N)ESS DISCONNECT(RAPID SHUTDOWN)ADJACENT TO MSPAUX PORTCOM WIRE (CAT 5)CONTROLLEDCONDUCTORCURRENT[200A]GATEWAY 2 INTERNAL PANEL200A BUSS,120/240V, 1PH, 3WGENERATIONWARNING: THIS SENSOR IS PART OF A POWERCONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLYWITH SAME TYPE AND RATING.21100A(N)SYSTEM DISCONNECT100A/240VF(POCC BREAKER SIZED FOR CRITICAL LOADS PANEL)N.C.CPOWERWALL PLUS = 40A x 1.25 = 50APOWERWALL 2 = 24A x 1.25 = 30ATOTAL = 64A x 1.25 = 80A50A30AFeature IntroductionAs per requirement from NFPA 70: 2020, 705.13, Tesla SiteController (PCS)software has implemented a Panel Limitfeature that monitors the amperage flowing into anelectric panel / busbar from all controlled and uncontrolledsources (Grid, Solar Inverter, and Powerwall). As themeasured current approaches the configured panel limit,the Site Controller first reduces the current contribution ofbatteries, then limits the output of solar. If the measuredcurrent of all sources combined exceeds the configuredPanel Limit for the site, the output of all PCS-controlledpower production sources will be curtailed to 0.PCS CONTROLLED PANEL CURRENT: 200ATHE PANEL CURRENT IS CONTROLLED FROM ALL SOURCESINCLUDING THE GRID NOT TO EXCEED THE RATING OF THE BUSBARNEC 705.13 (B)The sum of all PCS-controlled currents plus all monitored currentsof other sources of supply shall not exceed the ampacity of anybusbar or conductor supplied by the power production sources.Where the PCS is connected to an over current deviseprotecting any busbar or conductor not monitored by the PCSthe setting of the PCS conrtoller shall be set within the rating ofthat overcurent devise.ESSMETER+-FESSMETER+-WARNINGTHIS EQUIPMENT FED BY MULTIPLE SOURCES.TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN SUPPLYOVERCURRENT DEVICE SHALL NOT EXCEEDTHE AMPACITY OF THE BUSBAR21PCS CONTROLLED PANEL CURRENT:200ATHE PANEL CURRENT IS CONTROLLED FROM ALLSOURCES INCLUDING THE GRID NOT TO EXCEED THERATING OF THE BUSBARNEC 705.13 (B)2 STRINGS OF 10BPV DC INA2 STRINGS OF 10338,000 WATT DC (7,285 WATT AC)SOLAR ELECTRIC ARRAY20 TESLA 400 WATT MODULESMODEL NO. T400H20 x 373.6 PTC x 97.5% EFF = 7.285 kW AC INDIVIDUAL MODULE RATING: PTC = 373.6 WATTS Voc = 45.3 VDC Isc = 11.14 AMPS(E)MAIN SERVICE PANEL400A BUSS,120/240V, 1PH, 3W(E)MAIN SERVICE PANEL400A BUSS, SPLIT 200A120/240V, 1PH, 3W200AEXISTING AC GEC200AMSPESSMETER+-100ATESLA 7600+ = 32A x 1.25 = 40.00ANOTES:EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS.1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAICDISCONNECT.2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS-TERMINALS ON BOTH THELINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION"3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT VOLTAGE4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7.5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE.6.ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE.7.ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS.8.ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY.9.ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS.10.REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT CONDUCTOR.11.CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED.12.ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2022 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13.13.BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT.14.ANY LOADS RELOCATED TO A BU LOADS PANEL BEYOND SIX FEET SHALL REQUIRE AFCI PROTECTION.H o t P u r p l e E n e r g y H PSheet Number:Job Number:Title:Checked by:Date:Scale:Revisions:Date:Drawn by:810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com INTEGRATOR:Michael Rango760.322.4433 Lic. No. 940550Hildreth Residence 2213554895 Aristides Ct La Quinta, CA 922539/8/2022SFMJRSheetMichael RangoPV-3.0SINGLE LINE DIAGRAMNTS Rev B 1/20/23Rooftop conduit shall be installed a minimum of 7/8” above the rooftop.This item has been digitallysigned and sealed on03/09/202303/14/2023Deisy MendezBSOL2023-0020 1.1EPDM BOOT1.21.5"x 5.7" MOUNTING POST1.3TILE REPLACEMENT FLASHING1.43.5" X 5/16" SS LAG BOLTS W 2.5" EMBED1.5ADJUSTABLE MOUNTING SLED1.6BASE FLASHINGScale: 1" = 1'TYPICAL PEGASUS FALSHING DETAIL1NTSFLAT TILE FALSHING DETAIL4NTSW TILE FALSHING DETAIL3NTSS TILE FALSHING DETAIL2H o t P u r p l e E n e r g y H PSheet Number:Job Number:Title:Checked by:Date:Scale:Revisions:Date:Drawn by:810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com INTEGRATOR:Michael Rango760.322.4433 Lic. No. 940550Hildreth Residence 2213554895 Aristides Ct La Quinta, CA 922539/8/2022SFMJRSheetMichael RangoPV-4.0ATTACHMENT DETAILNTS Rev A 9/27/22This item has been digitallysigned and sealed on03/09/202303/14/2023Deisy MendezBSOL2023-0020 WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH THE LINE AND LOAD SIDEMAYBE ENERGIZED IN THE OPEN POSITIONDC DISCONNECTS AND J-BOXESCAUTION:SOLAR ELECTRIC SYSTEM CONNECTEDPLACE ON MSPCONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTINGALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BEINSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALLELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED.CEC ARTICLES 690.56(B) AND 705.10.FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALLLETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHERRESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT.NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2)TURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSCEC 690.56(C)(1)(A)Label for PV Systems that shut down the array and the conductors leaving the array.The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with aminimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall becapitalized with a minimum height of 4.8 mm (3∕16 in.) in black on white background.WARNINGPOWER SOURCE OUTPUT CONNECTIONDO NOT RELOCATETHIS OVER CURRENT DEVICEADJACENT TO BACK FED BREAKER705.12(B)(1)(3)(b)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMPLACE NEXT TO INVERTER AC DISCONNECTS690.56(C)(3)WARNING:PHOTOVOLTAIC POWER SOURCECONDUITS AND RACEWAYS EVERY 10'690.31(G)(3)PV INVERTER/BATTERYSERVICE PANEL (YOU ARE HERE)SYSTEM AC DISCONNECTESS SAFETY DISCONNECTGATEWAY/GENERATION PANELBATTERYSUB PANELHOT PURPLE ENERGY760.322.4433N1245763LEGEND:THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLARPANELS ON ROOFCAUTION54895 ARISTIDES CT, LA QUINTA, CA 92253PLACE ON BU/CRITICAL LOADS PANELBACK UP CRITICAL LOADS PANELBATTERY BACKUP CONNECTEDAC DISCONNECT - MAIN BREAKERMAX AC CURRENT : 64 A AC VOLTAGE : 240 VPV SYSTEM AC DISCONNECTWARNING - DUAL POWER SOURCESECOND SOURCE IS A PHOTOVOLTAIC SYSTEMMAX AC CURRENT : 32 A AC VOLTAGE : 240 VPLACE ON SYSTEM DISCONNECTSGENERATION COMBINER PANELWARNING - MULTIPLE POWER SOURCESPV AND BATTERY COMBINER PANELAC DISCONNECT - MAIN BREAKERMAX AC CURRENT : 64 A AC VOLTAGE : 240 VPLACE ON GENERATION COMBINER PANELPLACE ON ESS DISCONNECT AT MSPESS SAFETY DISCONNECTOPENING THIS SWITCH DISABLES THEBATTERIES AND DE-ENERGIZES ALLCURRENT CARRYING CONDUCTORS ATTHE SOURCEWARNINGTHIS EQUIPMENT FED BY MULTIPLE SOURCES.TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN SUPPLYOVERCURRENT DEVICE SHALL NOT EXCEEDTHE AMPACITY OF THE BUSBARPCS CONTROLLED PANEL CURRENT:200ATHE PANEL CURRENT IS CONTROLLED FROM ALLSOURCES INCLUDING THE GRID NOT TO EXCEED THERATING OF THE BUSBARNEC 705.13 (B)PLACE ON GATEWAY AND MSP8BU CRITICAL LOADS PANELH o t P u r p l e E n e r g y H PSheet Number:Job Number:Title:Checked by:Date:Scale:Revisions:Date:Drawn by:810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com INTEGRATOR:Michael Rango760.322.4433 Lic. No. 940550Hildreth Residence 2213554895 Aristides Ct La Quinta, CA 922539/8/2022SFMJRSheetMichael RangoPV-5.0WARNING LABELSNTS Rev A 9/27/22This item has been digitallysigned and sealed on03/09/202303/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy Mendez BSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020 03/14/2023Deisy MendezBSOL2023-0020