Loading...
BWFE2024-0059BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 02/09/2024 ISSUED DATE: 02/12/2024 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Wall / Fence 81705 HAFLINGER WAY BWFE2024-0059 780140008 Lot 83 MB 399/3 TR 32879 $10,000.00 RL, 83 Owner:GERALD HAMPTON CONNIE BURNETT Applicant:Armando Oros 46610 Bamboo St, Indio, CA 92201 Contractor:Armando Oros / 1039414 46610 Bamboo St, Indio, CA 92201 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 10/11/24 10:46 am Page 1 of 3 Permit Type: Permit Number: Property Address: Wall / Fence BWFE2024-0059 81705 HAFLINGER WAY BUILDING PERMIT 69LF OF 6' GARDEN WALLS AT NORTH AND WEST PROPERTY LINES [CITY STANDARD] 2022 CALIFORNIA BUILDING CODES. Use of Permit Construction Details 69Garden Wall Linear Foootage City StandardEngineering 69Total Block Wall LF 0Other fence Linear Footage 0Number of Receptacle/Light(s) RLZoning LDRGeneral Plan Within La Quinta LimitsCity Limits TR 32879Subdivision Name 83Lot Number 1825.9Lot Size 101149Centerlines Lot 83 MB 399/3 TR 32879Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00004377 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $3.96 Credit Card Convenience Fee $3.96 $61.02 Block Wall - First 100 LF $61.02 $76.28 Block Wall - First 100 LF PC $76.28 $8.00 Technology Enhancement Fee $8.00 $1.00 Building Standards Administration $1.00 $162.26 $162.26 Total for Invoice INV-00004377 Grand Total for Permit $162.26 $162.26 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 02/09/2024 0:00 02/09/2024 15:40 Building Review (1 Day) v.1 Receive Submittal 02/09/2024 0:00 02/09/2024 15:40 Permit Issuance v.1 02/09/2024 15:42 02/12/2024 11:54 Contractor / Owner-Builder Information v.1 Generic Action 02/09/2024 15:42 Verify & Invoice Fees v.1 Generic Action 02/09/2024 15:42 Ready to Issue v.1 Generic Action 02/09/2024 15:42 Verify Fee Payment & Issue Permit v.1 Generic Action 02/12/2024 11:54 Print, Attach, and Email Building Permit v.1 Create Report 02/12/2024 11:54 02/12/2024 11:54 Wall / Fence Inspections v.1 03/01/2024 0:00 Footing v.1 Inspection 03/01/2024 0:00 03/04/2024 10:22 Bond Beam v.1 Inspection 04/23/2024 0:00 04/24/2024 11:49 Bond Beam v.1 Inspection Final Inspections v.1 05/07/2024 0:00 05/08/2024 14:11 Final Wall / Fence v.1 Inspection 05/07/2024 0:00 05/08/2024 14:11 Printed: 10/11/24 10:46 am Page 2 of 3 Permit Type: Permit Number: Property Address: Wall / Fence BWFE2024-0059 81705 HAFLINGER WAY BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 10/11/24 10:46 am Page 3 of 3 PERMIT INSPECTION HISTORY REPORT (BWFE2024-0059) FOR CITY OF LA QUINTA Wall / Fence 02/09/2024Application Date:Permit Type:780140008Parcel Wall / Fence 02/12/2024Work Class:Issue Date:81705 HAFLINGER WAY LA QUINTA, CA 92253 Address: Finaled 04/24/2025Expiration Date:Status:Description:69LF OF 6' GARDEN WALLS AT NORTH AND WEST PROPERTY LINES [CITY STANDARD] 2022 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:GERALD HAMPTON CONNIE BURNETT Armando Oros Armando Oros Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 03/04/2024 03/04/2024 Footing IBLD-014987-2024 Approved Edward Ghera No Complete NOTES Created By TEXT Created Date Armando Oros Griffin Ranch - guard gate 03/01/2024 04/24/2024 04/24/2024 Bond Beam IBLD-018956-2024 Approved Edward Ghera No Complete NOTES Created By TEXT Created Date Armando Oros Griffin Ranch - Guard Gate 04/23/2024 05/08/2024 05/08/2024 Final Wall / Fence iBLD-019804-2024 Approved Edward Ghera No Complete NOTES Created By TEXT Created Date Armando Oros Griffin Ranch 05/07/2024 78-495 Calle Tampico Page 1 of 1October 11, 2024 Drawn by: B German FAX(760)776-6392 (951) 826-5697 City of Riverside Building Department Balcony/Deck Standard 390 Rivers 11/13/2014 RCLMNgdnwallFNL-Ppd.vsd AGE 1OF2 Western Riverside County Code Uniformity Program 0 Main StDrawn by: B German ideCA, 92522 Table Vertical reinforcement 3'17"#4 @ 48" O.C. 4'20"#4 @ 48" O.C. 5'23"#4 @ 48" O.C. 6'29"#4 @ 24" O.C. Table Vertical reinforcement 3'19"#4 @ 48" O.C. 4'22"#4 @ 48" O.C. 5'29"#4 @ 48" O.C. 6'34"#4 @ 24" O.C. #4 Horizontal rebar (use bond beam block) height from top of footing 6" or8" block #4 horizontal at 32" max. o.c. (use bond beam block) height from top of footing SEE TABLE "A" FOR REBAR SIZE AND SPACING (locate rebar in center of cell) SEE TABLE "B" FOR REBAR SIZE AND SPACING (locate rebar in center of cell) Finish grade (1) - #4 rebar continuous 12"10"(2) - #4 rebar continuous 10"12" Reverse direction of hook on every other rebar (FOOTING WIDTH) SEE TABLE All footings adjacent to slopes to beat least 5' to daylight as shown below. (FOOTING WIDTH) SEE TABLE BOTTOM OF FOOTING 5' MIN. NOTES: 1)this design does not allow grade differentials of more than 6"on opposing sides of the wall.This is not a retaining wall. 2)fence heights are regulated consult zoning regulations before beginning construction. 3)no water course or natural drainage shall be obstructed. 4)grout only the cells containing rebar.This wall is not designed for all cells to be grouted. 5)all rebar to be astm spec.A615,grade 40 minimum. 6)all rebar lap splices to be 24"minimum. 7)all masonry units to be astm C-90 grade N. 8)rebar to be centered in masonry cells. *SEE PAGE 2 FOR ADDITIONAL INFORMATION* DISCLAIMER: Alternate designs may be possible when provided with an engineered analysis.Use of this standard design is at the user s risk and carries no Check with the Building Department to verify if a building permit is required. When a permit is required,the following inspections are required: 1)FOOTING;Excavation trench clean with steel in place and supported 3"above and away from the surrounding earth/dirt. 2)REBAR/PRE-GROUT;Bond beam rebar and vertical rebar in place -inspection prior to placing grout. 3)FINAL;After grout is placed -prior to any decorative cap placement. Western Riverside County Code Uniformity Program City of La Quinta Building Department Freestanding Block Wall implied or inferred guarantee against failure or defects. (760)777-7125 FAX (760)777-7011 78-495 Calle Tampico, La Quinta,CA 92260 11/13/2014 Design and Development PAGE 1 OF 2 6'29"#4 @ 24" O.C. 5'29"#4 @ 48" O.C. Drawn by: B German Fax (951) 955-2023 (951) 826-5697 City of Riverside Building Department Balcony/Deck Standard 390 Rivers 11/13/2014 RCLMNgdnwallFNL-Ppd.vsd AGE 2OF2 Western Riverside County Code Uniformity Program 0 Main StDrawn by: B German ideCA, 92522 REBAR PLACEMENT ILLUSTRATION FOOTING OPTION B (TYPICAL) All rebar splices 24" min. overlap (TYPICAL) only cells and bond beam courses with rebar to be grouted (do not solid grout entire wall - use grout stop mesh as appropriate) FOOTING OPTION A DESIGN PARAMETERS: ACTIVE SOIL PRESSURE (PSF) = 30 PASSIVE SOIL BEARING (PSF) =150 COEFFICIENT OF FRICTION = 0.25 ALLOWABLE SOIL BEARING (PSF) =1500 WIND = 80 MPH, EXPOSURE C SEISMIC: Na=1.3,Nv=1.6,Z=0.4,SOILPROFILE=Sd (TYPICAL) All rebar shall have a minimum of 3" concrete cover at footings Western Riverside County Code Uniformity Program City of La Quinta Building Department Freestanding Block Wall (760) 777-7125 78-495 Calle Tampico, La Quinta,CA92260 FAX(760)777-7011 11/13/2014 Design and Development PAGE2OF2