BSOL2022-0591 Solar PlansGENERAL NOTES: 1. ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN. 2. ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741 SA CERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. 3. THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION. 4. PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. 5. THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PHOTOVOLTAIC SYSTEM OR INSTALLATION. 6. ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS. 7. ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS. 8. TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE Avenue 52 Avenue 52 Columbus WAY Ross Pye BSOL2022-0591 CI I i , OF LA QU 14Il"A- BU LO N G D VI 9 CN REVI EYED FOR CCCE CCInLI J CE BY:Deisy Mendez ME: 0311012023 20.5kW PV SOLAR - (50) 410W PANASONIC EVPV410 MODULES + TESLA BATTERY BACKUP SYSTEM 14KWH. [1000SF] 2022 CALIFORNIA ELECTRICAL CODE. Revisions: Date: Rev D 1/11/23 Michael Rango MiCit,Net JZGL1,610 760.322.4433 Lic. No. 940550 O icc -lot Purple Energy DESCRIPTION OF WORK: ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION TILT MOUNTED @ 5° FACING AN AZIMUTH OF 186° CONSISTING OF (50) PANASONIC EVPV410 - 410 WATT MODULES (20.5KW). AND INCLUDES A TESLA BATTERY BACKUP SYSTEM. RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND FAST JACK SOLAR STANCHIONS. INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: CEC 2022 - ARTICLE 690, 705,706 AND OTHERS CPC 2022 CBC 2022 CMC 2022 CFC 2022 CRC 2022 LA QUINTA MUNICIPAL CODE DRAWING SHEETS: COVER SHEET OPTIMIZER STRINGING NOTES {NOT FOR PERMITTING) SITE PLAN SYSTEM PERFORMANCE NOTES (NOT FOR PERMITTING) ROOF PLAN SINGLE LINE DIAGRAM MOUNTING DETAIL WARNING LABELING SPECIFICATION SHEETS: PANASONIC EVPV410 MODULE SOLAREDGE SE10000H-US HD WAVE INVERTERS TESLA POWERWALL2 TESLA GATEWAY 2 - UL1741 PCS CERTIFICATION HD6135FB HEAT DETECTOR SPEC SHEET UNIRAC CERTIFICATION PV-0.0 PV-0.0 (2) PV-1.0 PV-1.0 (2) PV-2.0 PV-3.0 PV-4.0 PV-5.0 This item has been digitally signed and sealed on 03/02/2023 ADDITION DOCUMENTATION: Powerwall Disconnecting Means to Comply with 706.7 of 2017 NEC or 2019 CEC Powerwall 2 ANSI-CAN-UL 9540A - 2019 Fourth Edition Test Report Supplemental Guide Powerwall 2 UL 9540A Checklist and Test Result 81325 Columbus Way Madison Club CC - CF1 RPRFO1 ENERGY REPORT Kaintz Residence COVER SHEET c>a E O U LC) N CO CO La Quinta, CA 92253 Drawn by: SF Checked by: MJR Date: 9/27/2021 Scale: NTS Job Number: 21236 Sheet Number: PV-0.0 Sheet OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING) 1 13 25 37 49 61 2 14 26 38 50 62 3 15 27 39 51 63 4 16 28 40 52 64 5 17 29 41 53 65 6 18 30 42 54 66 7 19 31 43 55 67 8 20 32 44 56 68 9 21 33 45 57 69 10 22 34 46 58 70 11 23 35 47 59 71 12 24 36 48 60 Panel S/N: BSOL2022-0591 CI TY OF LA QU N TA BU LD N G D VI 9 ON REVI EYED FOR COM COWL! AV CE B': Deisy Mendez E: 03110/2023 n 111111111111111111111111111111111111111111 Revisions: Date: This item has been digitally signed and sealed on 03/02/2023 0' 12.5' 25' 50' COLUMBUS WAY 2.4-2.7 PROPERTY LINE Hul WVnn1n'un - SITE PLAN KEYNOTE: EXISTING ELECTRICAL 1.1 600A MAIN ELECTRICAL PANEL NEW ELECTRICAL' (ADJACENT TO MSP INSIDE ELECTRICAL ROOM) 2.1 SYSTEM AC DISCONNECT 2.2 ESS SAFETY DISCONNECT 2.3 TESLA GATEWAY/GENERATION PANEL NEW ELECTRICAL (INSIDE GARAGE) 2.4 BU/CRITICAL LOADS PANEL 2.5 TESLA POWERWALL (x2) 2.6 SE10000H-US PV INVERTER (x2) 2.7 SYSTEM AC DISCONNECTS )x2) 2.8 HEAT DETECTOR SITE LEGEND FIRE EASEMENT/ACCESS EAVE SETBACK/WALL WORKING CLEARANCES SHALL BE PROVIDED AROUND ALL EQUIPMENT PER CEC 110.26 BSOL2022-0591 CI TY OF LA QU N TA BULONGOVISCN REVI EYED FOR COM COI'RLI Al CE B':Deisy Mendez ME: 03/10/2023 50 PANASONIC 410 WATT SOLAR MODULES (20.5KW) SPECIAL NOTE FOR ESS SYSTEMS:' 1206.11.6 OF THE CALIFORNIA STATE AMENDMENTS STATES THAT A SMOKE ALARM OR HEAT ALARM SHALL BE INSTALLED IN THE VICINITY OF THE BATTERY SYSTEM. (HEAT ALARMS SHALL BE USED WHERE SMOKE ALARMS CANNOT BE USED BASED ON THEIR LISTING - INSIDE A GARAGE.) HEAT ALARMS SHALL BE INTERCONNECTED WITH THE HOME SMOKE ALARM. 1206.11.2.1 INDIVIDUAL ESS UNITS WHEN INSTALLED SHALL BE SPACED 3' FROM EACH OTHER. 1206.4.5 WHERE ESS ARE SUBJECT TO IMPACT BY A MOTOR VEHICLE IMPACT PROTECTION SHALL BE PROVIDED BY THE INSTALLATION OF SAFETY BOLLARDS IN FRONT OF ESS. Rev E 3/2/23 Michael Rango J cfi.i t JZGL1,610 760.322.4433 Lic. No. 940550 O ct Z co N U 0) 0 Q M m U - L (n c� LL C N Z 0 cc) 0 0 0 E License No. 940550 -lot Purple Energy Kaintz Residence SITE PLAN ca 0 0 LC) N CO CO La Quinta, CA 92253 Drawn by: SF Checked by: MJR Date: 9/27/2021 Scale: 1"=25' Job Number: 21236 Sheet Number: PV-1.0 Sheet SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING) INVERTER M/N INVERTER M/N INVERTER M/N INVERTER S/N INVERTER S/N INVERTER S/N INPUT # 1 2 INPUT # 1 2 INPUT # 1 2 STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) AZIMUTH/ ORIENTATION AZIMUTH/ ORIENTATION AZIMUTH/ ORIENTATION SLOPE/TILT SLOPE/TILT SLOPE/TILT VOC @ Jbox VOC @ Jbox VOC @ Jbox VOC @ Inverter VOC @ Inverter VOC @ Inverter V+ to Gnd V+ to Gnd V+ to Gnd V- to Gnd V- to Gnd V- to Gnd AC L 1-L2 AC L 1-L2 AC L 1-L2 AC L1-N AC Ll-N AC Ll-N AC L2-N AC L2-N AC L2-N WATTS @ TIME OF DAY WATTS @ TIME OF DAY WATTS @ TIME OF DAY AMBIENT TEMP. AMBIENT TEMP. AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY WEATHER SUNNY PARTLY CLOUDY CLOUDY WEATHER SUNNY PARTLY CLOUDY CLOUDY AC POWER AC POWER AC POWER CREW NOTES: FLOFESS/p! McPyF F o BSOL2022-0591 0.82088 2 xp. 3/31/ * c/v\� �P qrF OF cA1-\O�� CI lY OF LA QU N TA BU LEI N GO VI 9 ON REVI EVED FOR This item has been digitally signed and sealed on 03/02/2023 COEE COIfPLI Al CE Bi: Deisy Mendez o E: 0E11012023 1.2 2.1 1111111111111111 • 4 4 IIL / 4 — 4I 7I� 1( 4I T HI -1 1 33' — 41 J 4 I I I 0' 4' 8' 4 l 35'-10O2" - ;Alllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll IIIIo 16' 8 '-8 11 MOUNT PLAN KEYNOTE: RACK MOUNT COMPONENTS 1.1 UNIRAC ALUMINUM SUPPORT RAIL 1.2 FAST JACK SOLAR STANCHIONS STRUCTURAL 2.1 14"TJI560@ 16"O.C. F NO ROOF VENTS, ATTIC VENTS OR OTHER NECESSARY BUILDING COMPONENTS MAY BE COVERED OR ALTERED BY THE INSTALLATION OF THE NEW PV ARRAY 4 Analysis of dead load weight ridded to- roof by installation of molar array Array #1 PanasonicEVPV410 45.00 Paunes No, of solar modules 50 Tdal w4i9h1 a m DeelA0 2,250 p0uhe0 Weight of each Solar Hack sat 10 pounds No- of rack sets 50-0 Tdal weight of rack sets 470 pounds Tdal weight of sofa. array Z720 pounds Height of each module Width of each module 5.98 feel 3.33 fee1 4.0 Area of one module 19.0 squ are feel A rea of entire solar array 005.7 sqL are feel IA/eight or solar array per unit Ar4+t1 appal' No. of stanchion; connected to m 'jalst rapers Weight loading per atanc hien 2.7 100 MOE p4Ynesr64U44e tot parnes?corntctial 11 1. VERIFY RAFTER SPACING IN THE FIELD BEFORE ATTACHING MOUNTS ROOF. 2. ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF RAFTERS AND MAKE STRUCTURAL CONNECTION TO THE RAFTERS. 3. STRUCTURAL CONNECTION TO ENGINEERED TRUSS SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG iARA SCREWS 3" MIN. EMBEDMENT. - - 4. ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS. 5. PHOTOVOLTAIC MODULES SHALL HAVE 1.9 MOUNTS (LAG SCREWS) PER PANEL. (E) ROOF STRUCTURE IS FLAT 11-7/8" TJI360 @ 16" O.0 6. (E) ROOFING MATERIAL IS 1 LAYER OF TPO OVER 1 LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD inn DECKING. Revisions: Date: Rev D 1/11/23 Michael Rango 714,iLAi.t t JZPV1410 760.322.4433 Lic. No. 940550 7. MODULE DIMENSIONS 71.7" x 40.0" mounts per module lags per module — th Ole 110ch9 48" SPACING BETWEEN MOUNTS IS TYPICAL F1is item has been digitally Egned and sealed on t /02/2023 O gct V Lu co a) U O) O 0 O M 0) f9 c ) u- C N Z CO NM-. 007) ETo License No. 940550 Z E E U U E5 E C C m a) QL 0 0 a2 o Hot Purple Energy IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII BSOL2022-05911 CI TY OF LA QU N TA BU LD N G D VI 9 ON REVI EYED FOR Ca" COWL! AV CE BY Deisy Mendez DE: 0311012023 • r H Kaintz Residence ROOF PLAN 81325 Columbus Way La Quinta, CA 92253 Drawn by: SF Checked by: MJR Date: 9/27/2021 Scale: 1"=5' Job Number: 21236 Sheet Number: PV-2.O Sheet Revisions: Date: Rev E 3/2/23 20,500 WATT DC (19,389 WATT AC) INDIVIDUAL MODULE RATING: SOLAR ELECTRIC ARRAY PTC = 391.7 WATTS 50 PANASONIC 410 WATT MODULES Voc = 49.0 VDC MODEL NO. EVPV410H Isc = 10.35 AMPS 50 x 391.7 PTC x 99% EFF = 19.389 kW AC 1 STRING OF 13 O 0 0 O 0 0 O 0 0 1 STRING OF 12 O 0 0 1 STRING OF 13 13 12 13 J-BOX SOLAREDGE POWER OPTIMIZER P400 RATED DC INPUT POWER - 400 WATTS MAXIMUM INPUT VOLTAGE - 80 VDC MPPT RANGE - 8 TO 80 VDC MAXIMUM INPUT CURRENT - 12.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5250 WATTS STC PER STRING MAXIMUM DC IN O -0 l50-0 too O -0 AC OUT SOLAREDGE SE10000H-US GRID -TIE INVERTER INPUT: 400 TO 480 VDC OUTPUT: 10000 WATTS MAX OUTPUT EFFICIENCY: 99% 240 VAC, 42 AMPS MAX INTEGRATED GFCI AND DC DISCONNECTS SolarEdge systems are not solidly grounded (functional grounded) PV systems as permitted under Article 690.47. J-BOX PV DC IN L L O 0 0 1 STRING OF 12 O 0 0 12 Lo-0 Loo AC OUT SOLAREDGE SE10000H-US GRID -TIE INVERTER INPUT: 400 TO 480 VDC OUTPUT: 10000 WATTS MAX OUTPUT EFFICIENCY: 99% 240 VAC, 42 AMPS MAX INTEGRATED GFCI AND DC DISCONNECTS THE BREAKER IN THE GATEWAY GENERATION PANEL SERVES AS A MEANS OF DISCONNECT IN -LINE -OF -SITE FOR THE ESS IN ADDITION THERE IS A EXTERIOR BATTERY SWITCH ON THE ESS THAT ALSO SERVES AS A MEANS OF DISCONNECT COMPLYING WITH CEC 706.7 J� Rooftop conduit shall be installed a minimum of 7/8" above the rooftop. ALL CONDUCTORS SHWA 66 COPPER UNLESS OTHER W ISEL SPECAED 10 WARE AND CONDUITSCWEEULE AMPS MULTI -Ate, F71ES AMPS WIRE GUAGF SDI. WIRE AMPS 90C TEMP DEBATE FACTOR WHiE DERAT112G3L AMPS Al"' L.'.-1 75 WIRE AMPS 75C WERE TYPE USES GNO SIZE COMO. CWTY CONDUIT FILL FACTOR CONDUIT SUE CONDUIT TYPE A MODULE TO!-60% 15 L56 23.40 10 40 0,71 2&R6 ID 35 RNA'-2 6 2 L HA FR6E611 - R J-80x TOII6vERTER 15 1.56 23,40 10 40 0.61 32,66 10 35 771WN-2 8 2 1 0.50 MIEFAau0 - C SEt006161415 TO GATEWAY GENERATION PANEL 42 1-25 5250 6 75 0.81 6075 6 55 THWN•2 8 3 1 0.75 METALLIC D TESLABATTERO TO GATEWAY GENEELIAT14N PANEL 24 125 1010 10 40 081 3216 10 15 THWN2 8 3 1 O,50 METALLIC E EAJ LOADS PANEL TO GATEWAY 175 1 175-00 • 3/0 225 081 182,05 b 3/0 200 THWN.2 6 3 1 1.06 METALLIC -- F GATEWAY TO A[ DISCONNECT 175 1 125.00 . 3/D 225 0.61 162.25 a 3/0 200 TNWN-2 6 3 1 LW M1ETAa11C -- G AC DISCONNECT TOMSP 175 1 175.03 ' 3/6 123 0,61 162.25 a 3/0 200 7HWN-2 6 3 1 2.06 METALLIC -- -DC Its VALL7F5 ACCOUNT FOR 12596 CLOUD FHFIANCEMENTjHEC MAN { 111 (N) SYSTEM DISCONNECT 60A/240V 60A 0 EXT RIOR BATTERY SWITCH AC O▪ UT TESLA POWERWALL 2 USABLE ENERGY 13.5kwh MAX OUTPUT 5kW POWER FACTOR +)- 0.85 240V/24A Q TPN # 1092170-xx-x m EXT RIOR BATTERY SWITCH TESLA POWERWALL 2 USABLE ENERGY 13.5kwh MAX OUTPUT 5kW POWER FACTOR +)- 0.85 240V/24A ❑■ TPN # 1092170-xx-x 1206.11.2.1 INDIVIDUAL ESS UNITS WHEN INSTALLED SHALL BE SPACED 3' FROM EACH OTHER. 60A/240V 60A ti 175A BREAKER (N) BU CRITICAL LOADS PANEL 200A BUSS, 120/240V, 1 PH, 3W 0 ETER SE10000H-US = 42A x 1.25 = 52.5A SE10000H-US = 42A x 1.25 = 52.5A POWERWALL = 24A x 1.25 = 30.0A POWERWALL = 24A x 1.25 = 30.0A TOTAL = 132A x 1.25 = 165.0A PCS CONTROLLED CURRENT SETTING: 84A The maximum output current from this system towards the main panel is controlled electronically. Refer to manufacturer's instructions for more information. J "- ciNDUCTcR551EED FOR RU/CRITICAL LOADS PATJE1 (N) ESS DISCONNECT (RAPID SHUTDOWN) ADJACENT TO MSP N.C. CO M WIRE (CAT 5) TESLA GATEWAY 2 - N #1232100-xx x 60A n 60A 30A 6-2 30A GENERATION C. CONTACT PCS .TER CONTROLLED CONDUCTOR I I CURRENT This item has been digitally signed and sealed on 03/02/2023 (N) SYSTEM DISCONNECT GATEWAY 2 INTERNAL PANEL 200A BUSS, 120/240V, I PH, 3W [84A] WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR C WARNING: THIS SENSOR IS PART OF A POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH SAME TYPE AND RATING. \ J NOTE: Tesla battery does not export, load in the BU/critical loads panel self -consume battery current. Tesla gateway as a PCS (power control system) limits the backfeed to the rated output of the photovoltaic interactive inverter rated output 184AJ.The 175A POC breaker is sized for existing loads in the BU/critical loads pane . Only photovoltaic current is considered in the POC calculations, where the output of the PCS shall be used to calculate conductor and over current protection to protect overloading buss bars in distribution equipment. While the 2020 NEC has formally introduced a Power Control System , it allows for backfeed that exceeds the 120% rule. Conductor Export Limit implemented with the Powerwall system is designed to function in compliance with the 120% rule from the 2019 CEC, 2017 NEC, and 2014 NEC. This Conductor Limit feature is beneficial for safely connecting a larger amount of energy storage on a site, without overloading the busbar. (See additional notes related to TESLA UL 1741 PCS and the control of bock feed current by the Power Control System) NOTES: EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 0. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC DISCONNECT. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS -TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION" PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT VOLTAGE LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7. INDIVIDUAL MICRO INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE WHEN USED. ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE. ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS. ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS. REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT CONDUCTOR. 200A/240V 175A f7 © SE10000H-US = 42A x 1.25 = 52.5A SE10000H-US = 42A x 1.25 = 52.5A TOTAL = 84A x 1.25 = 105.0A 600A x 1.2 = 720A 720A - 600A = 120A 105A <= 120A (POCC BREAKER SIZED FOR CRITICAL LOADS PANEL) c6▪ 175A (E) 1AIN SERVICE PANEL 600A BUSS, 120/240V, 1 PH, 3W EXISTING AC GROUNDING ELECTRODE CONDUCTOR 1 PROVIDE NEW ELECTRODE IF NOT EXISTING PER CEC 250.53 (A) (2) 1. CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED. 2. ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2022 CALIFORNIA ELECTRIC CODE. 3. BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT. 4. ANY LOADS RELOCATED TO A BU LOADS PANEL BEYOND SIX FEET SHALL REQUIRE AFC! PROTECTION. 5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (CEC 250.90, 250.96) 6. BOTH METALLIC WATER PIPING WITHIN 5' OF ENTRANCE AND GAS PIPING INSIDE THE BUILDING ARE REQUIRED TO BE BONDED (CEC 250.104) 7. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE -PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM (CEC 250.97) 8. WHERE DC CONDUCTORS ARE INSIDE THE BUILDING (OR ATTIC) THEY SHALL BE CONTAINED IN A METAL RACEWAY. CONDUIT SHALL BE SHALL BE RUN ALONG THE BOTTOM OF LOAD BEARING MEMBERS. (CEC 690.32E, CRC R331.3, CBC311.3) 9. THE NEUTRAL TO GROUND BOND MUST BE REMOVED IN THE TESLA GATEWAY. 20. ESS (BATTERY) TO BE INSTALLED PER THE MANUFACTURE CLEARANCE REQUIREMENTS 21. ESS CONFORMS TO AND IS LISTED UNDER UL 9540 22. ESS LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE 23. ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE ENERGY STORAGE DEVICE INPUT AND OUTPUT TERMINALS ARE MORE THAN 5' FROM CONNECTED EQUIPMENT, OR WHERE THE CIRCUITS FROM THESE TERMINALS PASS THROUGH 24. WORKING CLEARANCES SHALL BE PROVIDED PER CEC 110.26 25. WHEN A BACKFED BREAKER IS THE METHODS OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD PER CEC 690.13(F)(2) BSOL2022-0591 CI TY OF LA QU N TA EULEI NGCIVISON REVI EYED FOR COM COIIRLI AN CE WALL OR PARTITION. Eft Deisy Mendez E: 4311412423 Michael Rango /ZA44.10 760.322.4433 Lic. No. 940550 License No. 940550 Hot Purple Energy Kaintz Residence SINGLE LINE DIAGRAM 81325 Columbus Way La Quinta, CA 92253 Drawn by: SF Checked by: MJR Date: 9/27/2021 Scale: NTS Job Number: 21236 Sheet Number: PV-3.0 Sheet Revisions: Date: Rev C 8/25/22 2.1 This item has been digitally signed and sealed on 03/02/2023 BSOL2022-0591 CI TY CF LA G*J N TA BULONGOVISON REVI EV'ED FOR CCM COMM AV CE BY:Deisy Mendez E: 03/F0/2023 1.3 \ / / / / / 1.5 MOUNT DETAIL KEYNOTE: RACK MOUNT COMPONENTS 1.1 PHOTOVOLTAIC MODULE 1.2 MODULE CLAMP 1.3 UNIRAC "SOLARMOUNT" SUPPORT RAIL 1.4 SS RAIL T-BOLT AND NUT 1.5 UNIRAC L-FOOT 1.6 ADJUSTABLE ALL TREAD 1.7 FAST JACK SOLAR STANCHION (4.5" - 7" typical) 1.8 3.5" SS LAG SCREWS (3" minimum embedment ) 1.9 TPO FLASHING (BOOT) STRUCTURAL 2.1 TPO MEMBRANE ROOF COVERING 2.2 1/2" OSB ROOF DECKING 2.3 2 x 10 ENGINEERED TRUSS (RAFTER) 16" O.C. TYP. 1 / 1 5-7 DEGREE TILT DETAIL Scale: 1" = 1' Michael Rango MiCit,Net JZGL1,610 760.322.4433 Lic. No. 940550 810 N. Farrell Drive CO 0 U U > 0) p 2) En aco o a) a) U co 1 m m 0) ' z° a n N N 7 D L N 0- 0__ Eo : =_ o ©3 a o3 L L -lot Purple Energy Kaintz Residence ATTACHMENT DETAIL ca E O LC) C CO CO La Quinta, CA 92253 Drawn by: SF Checked by: MJR Date: 9/27/2021 Scale: 1"=5' Job Number: 21236 Sheet Number: PV-4.0 Sheet CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. CEC ARTICLES 690.56(B) AND 705.10. FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE ADJACENT TO BACK FED BREAKER 705.12(B)(1)(3)(b) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PLACE NEXT TO INVERTER AC DISCONNECTS 690.56(C)(3) WARNING: PHOTOVOLTAIC POWER SOURCE CONDUITS AND RACEWAYS EVERY 10' 690.31(G) (3) This CAUTION: signed SOLAR ELECTRIC SYSTEM CONNECTED 03/02/2023 PLACE ON MSP BS0L2022-0591 Revisions: Date: Rev D 1/11/23 GENERATION COMBINER PANEL WARNING - MULTIPLE POWER SOURCES PV AND BATTERY COMBINER PANEL AC DISCONNECT - MAIN BREAKER MAX AC CURRENT : 132 A AC VOLTAGE : 240 V PLACE ON GENERATION COMBINER PANEL Michael Rango MickA-Ct rCA646Afo 760.322.4433 Lic. No. 940550/ 810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com BACK UP CRITICAL LOADS PANEL BATTERY BACKUP CONNECTED AC DISCONNECT - MAIN BREAKER MAX AC CURRENT QFiOFESS/p� o. 82088 2 [mA" qTF OF CAOF��� :132A AC VOLTAGE: 240 V PLACE ON BU/CRITICAL LOADS PANEL CAU ION THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF 81325 COLUMBUS WAY, LA QUINTA,CA 92253 5 ' I — ' ° U 2 _iky' � I1l:il:l 111 111111 o '' IIIIIIII►I �1' 1111111111 � 8 LEGEND: 0 1 SERVICE PANEL (YOU ARE HERE) 2 SYSTEM AC DISCONNECT 0 03 ESS SAFETY DISCONNECT ®TESLA GATEWAY/GEN PANEL 0 5 6 CRITICAL LOADS PANEL 0 PV INVERTER �7 BATTERY ® ROOF MOUNTED SOLAR O HOT PURPLE ENERGY 760.322.44330 INTEGRA TOR: el P 0 -lot Purple Energy item has been digitally and sealed on ESS SAFETY DISCONNECT OPENING THIS SWITCH DISABLES THE BATTERIES AND DE -ENERGIZES ALL WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAYBE ENERGIZED IN THE OPEN POSITION CI lY OF BU LEI N REVI E al N TA ry VI a /y�� L.1 �7 MY D FOR CURRENT CARRYING CONDUCTORS AT THE SOURCE PLACE ON ESS DISCONNECT AT MSP AND INDIVIDUAL ESS PV SYSTEM AC DISCONNECT Title: Kaintz Residence WARNING LABELS 81325 Columbus Way La Quinta, CA 92253 DC DISCONNECTS AND J-BOXES CCC Deisy Mendez LI AV CE DIE: 0311012023 WARNING - DUAL POWER SOURCE SECOND SOURCE MAXACCURRENTPHOTOVOLTAIC ASYSTEM AC VOLTAGE : 240 V SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO soLAR LECTRIC PVPANELS SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY . PLACE ON GENERATION PANEL PCS CONTROLLED CURRENT SETTING: 84A The maximum output current from this system towards the main panel is controlled electronically. Refer to manufacturer's instructions for more information. PLACE ON GATEWAY AND MSP (2) MAXIMUM VOLTAGE 480 V MAXIMUM CIRCUIT CURRENT 27 A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC -TO -DC CONVERTER (IF INSTALLED) 15A PLACE ON DC DISCONNECT SE10000H-US Drawn by: SF Checked by: MJR CEC 690.56(C)(1) (A) Date: 9/27/2021 Label for PV Systems that shut down the array and the conductors leaving the array. The title "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" shall utilize capitalized characters with a minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (316in.) in black on white background. Scale: NTS Job Number: 21236 Sheet Number: PV 5.0 Sheet EverVo t EVERVOLT" SOLAR MODULE SERIES Panasonic EverVof f EVE WELT" SOLAR MODULE SERIES Panasonic 41 OW/400W PRELIMINARY 41 OW/400W PRELIMINARY The Panasonic Advantage ccb Higher Module Efficiency Superior module efficiency of 22.2% and 21.6%, respectively, allows maximum power production with Less roof space. With one of the industry's lowest annual degradation rates, power output of at least 92% is guaranteed after 25 years. ALLGuard and TripleGuard 25-Year Warranty' A long-term warranty is only as reliable as the company behind it. AllGuard and TripleGuard 25-year warranties cover EverVolt panels for performance, product, parts and labor for 25 years. Whether in year three or year 25, your Panasonic warranty will be there when you need it. High Efficiency in High Temperatures Produce more energy throughout the day even on the hottest days in the warmest climates, EverVolt solar panels outperform others when temperatures rise due to our industry -leading 0.26%/°C temperature coefficient. Heterojunction Cell Technology with Gapless Connections Half -cut cells with heterojunction technology with gapcell connections minimizes electron loss, maximizes conversion efficiency, and produces considerably higher power output over conventional panels. Durability & Duality Assurance N-type cells result in minimal Low Induced degradation [LID] and Potential Induced degradation [PIDI, which supports reliability and Longevity. As a solar pioneer for over 40 years, Panasonic EverVolt solar panels are backed by innovation, experience and a brand you can trust. Improved Performance When Shaded Continuous power production in shaded areas for greater energy yields and output. More sunlight absorption means more clean power to your home. Panasonic Panasonic Life Solutions Company of America Two RiverfronI Plata, Newark, N) 071D2 panascnicHtTi3 us. CanaOnlc.rC r1 na.pan a so nic _comlustsolar TRIPLE GUARD WARRANTY r f.. ter] r r, 'J rirf .J * PROnIicT PERFORMANCE LABOR `tdrht1ghts' -etve, - tr 21'ob r1JCHf P=na,n•r •:arprrar•ne 5 ri�::.ifl;,r1i[i�o•:sir^'•u 11irr.1 ID: .41 ifi wilhnut nntir.r ELECTRICAL SPECIFICATIONS Mi.J�l EVPV414H EVPV400FI Rated Power I 'max]' Maximum Power Voltage lVprnl Maximum Power Current flpml Open Circuit Voltage IVoci Short Circuit Curren t I Iscl Temperature Coeflicient IPrnaxl Temperature Coefficient IVocl Temperature Coefficient llsci NOC7 CEC PTC Rating Module Efficiency f court f1Qr5i y Maximum System Voltage Maximum Series Fuse 1 1 Watt CMS Sorting 41DW 42.7V 4.61 A 49.ov 16.35A 390 4W 22.2% 21.9 wfrt2 - 0.28 $6j°C - 0.24 %/ C 0.04 %1° C 44°C [t2°Cj 1000V 25 A -01+10W 4O0 W 42.1V 9.51 A 48.8V 10.25A 381.OW 21 6% 20.6 WA' MECFIANICAL SPEC! FICATIONS JunctLon Boil Connector Type Cable Size ! Type Max Snow Load lilt Max Wind Load I-P D.mensians LxWxH Weight Pallet Oimensions LxWxH Quantity per Pallet! .Pa[let Weight Quantity per 40. Container +Test Lead Design load should be multiplied by two thirds 3-part, 3 bypass diodes, IP68 rated in accordance with IEC 62740 Sldutsli MCd PV-K8T4JK5T4 14 mm'I in accordance with IEC 628E2 only when connected 12AWG[4mm21 PV Wire, 43in +47in in accordance with EN 50618 146pat17000lal' 53.5 psiI4808 Pa]` 71.7x43.0x1.2in [1821 x1016x30mrtd 45_0 Ibis [20.5kg1 74x41.5x47.5in 33 pcsl 16201bs,[735kg] 792 pcs OPERATING CONDITIONS AND SAFETY RATINGS Certifications IEC6t215-2:2016 [Hailstone 35mm] Fire Type 21UL 61730.1 Salt Mist DEC 81761] P10 [IEC 62806] Ammonia Resistance DEC 627161 Lead-free err- to Ra*S EU 863I2015 DEC 62321] Operating Temperature-40°Fto 195aF I-409Cto S59C1 L mtedVJarranty 25" Yrs Workman sh i p and Power Output [Linear]-" Power Output in Year 1 98% Annual Degradation 0,15%1 Power Output in Year 25 42% NOTE_ Values at standard test eonditions[STC: air mars AM1.5 irradiance 1000W jrto2. temperature 25°C1. Maximum power at detienryc Forgearantet conditions. please chock our guarantee document. `• rn2talletion need to be registered through our webeite venw.panasortc dsehi1warranty.vom within 6l days in order to receive twerdy-Five i251 year Product workmanship. Otherwise, Product Workmanship will be only Fifteen i151 years. 'Equipment must be in:t ilted by a Panasonic Authorised, Premium. or Etite installerand registered a[ wwncpamiser, icusahitwarranty.veto within 600 days in outer tv receive- twenty -fire 1251 year ALLGuard and TripleGtiae Narranty, ' Refer to Installation manual far detailed mechanical Loading Inlermation '•' 1st year PEN, after2nd year D.25%annual degradation hayear 25. DIMENSIONS 7L.7oL1 nMi1:7.11 1.1gal 26.5(1110 1S111i10 L ry ro+ t e,o5 [1i3.t1 + txa [hoot + it lilrl• .3] . O.tl:1A1 [a.t4.21 I i!r 1 li,11=1.ER -e. 111.5r1.5J +' 4r.20l0o1 �dffi3163.1] { �} . - u+ u., UM 16.4d.14 G711 I r Lulu] Meepnrmee6la M fern] 1 11111] DEPENDENCE ON IRRADIANCE +2 11 0 0 10 21 i0 voltage Iwl 1c00Wlma Er0trivim. saowh,ta Reference dale for modal ; EVPV410H Cell temperature : 77°F 425°CI Al L NOTE: SpevlNrations and Information above may hangs wllhaul native, .CAUTION! Please read the installation manual carefully before using the products. Usedelecrrcal and olecirork products niost not be mired wit general heueebeldwaete. For proper treatment. recovery acid rbeyc8ing of old pnoducts. please Lake dram to applicable collection points in accordance with your roationaL Legislation. Panasonic Panasonic Life Solutions Company of America Two Rival -front Plaza, Newari;, N.) 0710E panasonic!-I111r[rlus.panasonic.com na-panasoni c.coraus/solo r 411 Rights Reserved 2021 COPVRIOHT P2naEn.r Corparasioo 5pecifical ions are subject to change without notice R92144905-r5 Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US • • • • tS • 0 �a d soler,7 fig • • • • Optimized installation with HD -Wave technology 1 Specifically designed to work with power optimizers 1 Record -breaking efficiency I Extremely small 1 Built-in module -level monitoring 1 Fixed voltage inverter for longer strings 1 Outdoor and indoor installation 1 Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 1 UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge,com 1 Optional: Revenue grade dater ANSI C12.20 Class 0.5 (0.5% accuracy) S131b3ANI solar- • • 1 Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE3000H-US SE3800H-US 5E5000H-US SE6000H-US 5E7600H-US SE10000H-US 5E11400H-US OUTPUT Rated AC Power Output 3000 i300 240V 3300 V 206U 5000 a000 @ 240V 5090 V 208V 7600 1p� 11400 @ 240V 10000 V 2138V VA Maximum AC Power Output 3000 3800 [ 249v 3300 @ 20BV 5000 6000 240V 5000 @ 208V 7604 10000 11400 240V 10000 V 29BV VA AC Output Voltage Min. Nam, -Mohr. (211 -240 • 264) ✓ ✓ ✓ ✓ ✓ V. ✓ Vac AC Output Voltage 1w1fn.-Nom.-tabu. (183 - 20B - 229) _ d _ ✓ _ - ,r Vac AC Frequency (Nominal) 59.3 - 60 - 6051> Hz Maximum Continuous Output Current €240V 125 16 21 25 32 42 47,5 A MaximumContrnuousOutput Current 0208,1 - 16 - 24 - 485 A GFDIThreshold 1 A Utility Monitoring, isianding Protection, Country Configurable Thresholds. Yes INPUT Maximum DC Power V240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @1208V - 5100 - 7750 - - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current CLx}240V6r 8.5 10.5 13,5 16.5 20 27 30.5 Adc maximum Input Current 0208V'' - 9 - 13.5. - - 27 Arc Max. Input Short Circuit Current 45 Ad[ Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600L2 Sensitivity Maximum Inverter Efficiency 99 99.2 9a C£C Weighted Efficiency 99 99 2 20 V 98.5 ® 208V % Nighttime Power Consumption - 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Zigfee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional"' Rapid Shutdown - NEC 2014 and 2417 695.12. Automatic Rapid shutdown upon AC Grid Dis onnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C222, Canadian AFC according to TI.L. M-07 Grld Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size! AWG Range 1' Maximum / 14-6 AWG 1' Maximum /14-4 AWG DC Input Conduit Size / of Strings / AWG Range 1' Maximum! 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety switch (HeWxD) 17,7 x 14,6 x 6.5 / 450 x 370 x 174 21, 3 x 14.6 x 7-3 / 540 x 370 x 185 n f mm Weight with Safety Switch 22 / 10 251 / 11.4 262 / 11.9 388 ! 17.6 14 / kg Noise ' 25 s50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to f50e (-407 / -4([C option(1" 'F /'C protection Rating NE MA 41‹ (Inverter with Safety Switch) n Far the reglc'al aaktin9i please contact SeiarfdDe Support m A 190er clrrent score may he used; the irw eter di limit its input current *the values stated of Revenue grade inverter PM SEoo,HHJS000NMC2 w far power de -rating informallon refer to: https. wvrwsciaredge.aam/sitesjdeiau lvfileslst temperature-denting-note-na.pdf ' -40 version P/N: SEooaH-USO NNU4 45ntrrEdge Technologies Inc. All rightb. merited. 57[AREEGE the SofarEdpe rogo,, OPTIMIZED 6Y SOEAREOGE are trademarks or -registered trademarks of So}arEdge iedtnolagres, Inc, All other trademarks mentioned herein aretradenharks or their respective owners Date 03)2019N011/NG HAM- Subject to change without notice. RoHS Power Optimizer For North America P320/P340/P370/P400/P401/P405/P485/P505 PV power optimization at the module -level 1 Specifically designed to work with SolarEdge inverters 1 Up to 25% more energy 1 Superior efficiency (99.5%) I Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading 1 Flexible system design for maximum space utilization 1 Fast installation with a single bolt 0 m O N m / Next generation maintenance with module - level monitoring 1 Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) 1 Module -level voltage shutdown for installer and firefighter safety solar- •• / Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer mode (typical module compatibility) P320 (for 60-cell modules) P340 (for high - power 60-cell modules) P370 (for higher - power 60 and 72- cell modules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell Modules) P4OS (for high - voltage modules) P485 (for high - voltage modules) P505 (far higher current modules) INPUT Rated Input DC Poweto 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Vac at lowest temperature) 48 60 80 60 1250 830 Vdc M PPT Operating Range 8 - 48 8 - 80 8 - 80 8-60 12.5 -105 12.5 - 83 Vt lc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maxirnum EfftcIerky 99.5 % Weighted Efficiency 98.8 98-6 46 Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output MYtage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Lbltage per Power Optimizer 1 f 0.1 Vdc STANDARD COMPLIANCE EMC FCC Partl5 Class13, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1(class II safety), 1JL1741 Material 1JL94 V-0, 1N Resistant IioHS Yes INSTALLATION SPECIFICATIONS Maximum allowed System Voltage 1000 lfdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters DimensionsNhrxLxH) 129x153x27-5/51x6x1.i 129x153x33-5 /5,1x6x1.3 129x153x29.5 /5.1x6x1,16 129x159x49-5/5.1x5.3x1-9 129r162xS9/ 5,1x6.4ic2.3 mm /in Weight (including cables) 630 J 14 750 / 1.7 6S5 / 1.S 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC40+ Single orual moo input Wire Length 0.18/0.52 milk Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0-9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Ranges -40 - +85 / -40 - +185 'C I'F Protection Rating IP68 r NEMA6P Relative Humidity 0 -100 % CI) Rated power of the module atSTC will not exceed the ophrazes'Rated Input DC Power. Modules will up to +5% power tolerance are Mowed (4 MC an? requres mac input voltage be riot mqe then eW {3) For other connector types please cornett Soto/Edge (4) For dual serum for paraSel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules In cne string. Installing one P485 dual version power optimizer connected to one PV mnodule. When connecting a single module seal the unused elput connectors with the supplied pair c4 seals {5) Far amhiertttemperature above �85°C f +155'F pvrcr tie-rat]rg is applied Refer to PthoW OptiNizes'temperature L+e-Ratiag Tedmiral Now tar more delells- PV System Resign Using a SolarEdge Inverter:6m, Miniirbm SLi:rig Length (Power Optimizers) C., P370, P400: P4C1 PLOP, P485, P505 Maximum str-ing tengti (Power Optimizers) Maximum Power per String Parallel Stdngs of Different Lertpths or Orientdbons Pimsc LkD-Wave S:nclle phase 8 6 25 5700 (6000 with SE7,500-OS - Sl•11400- US) S250 Three Phast• foie Three Phase for ei18\a' y+iel 10 8 2'7 480V yrtei 18 14 25 50a t27S0m Yes {6) For detailed suing stlirlg information referto: hit yit.wmwlaredge eri shesJdefaultaleslstrlrrg_siz napdf {7) rtis. not allowed to mix P4051P46 P505 with P320/P34415379/P40O/P401 in one string (8) Airing with morn, noon 30 optimizers does not meat NEC rapid slx,trltwn requirpmertrm safety voltage will be eta the 30V rerramment For 2011) grid' it is allowed to instal up W 7.200W per string when the maximum power diffeoence between eadt wing is UMW {10) For 2777480V grist it is aimed do install up to 15,030W per string when the rneetsarn power difference between each striig a 2,0W W W solaredge.com o SolarEdge Technelegies LAM Alba renewed 50iMitOrA, the SekerFdge lags, OPWEE❑ ate SOLAREDGE are traelemeAner registered trademarks er SararEdge Technologies, ]ne Aid other lraehemarks mebaned hereto are eadetnart3 of thst hespeom aaaers. auL07aolSkNi2rSNG NAPA. S.Isyeet to change w,thaut aa1]ee. Intertek Ro H S POWERWALL Backup Gateway 2 The Backup Gateway 2 For Tesla Powerwall provides energy management and monitoring For solar self -consumption, time -based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. s PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage (Nominal) 120/240V Feed -In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA' Overcurrent Protection Device 100-200A; Service Entrance Rated' Overvoltage Category Category IV AC Meter Revenue accurate (+/- 0.2 %) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self -consumption, time -based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC -coupled Powerwalls Optional Internal Panelboard 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years 'When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide Internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi -flush mount T s M L w 660 411 - COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Certifications UL 67, UL 869A, UL 916, UL 1741 PCS Operating Temperature -20°C to 50°C (-4°F to 122°F) CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 Operating Humidity (RH) Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R NA 2020-05-23 TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully -integrated AC battery system for residential or light commercial use. Its rechargeable lithium -ion battery pack provides energy storage for solar self -consumption. time -based control, and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable. clean power. TYPICAL SYSTEM LAYOUTS WHOLE HOME BACKUP Optional Solar Solar inverter TESLE • CM CM MM O CM CM CM CM \ Main panel Backup Gateway including service disconnect O Utility meter Grid PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240 V Feed -In Type Split Phase Grid Frequency 60 Hz Total Energy' 14 kWh Usable Energy' 13.5 kWh Real Power, max continuous 5 kW (charge and discharge) Real Power, peak (10s, off-grid/backup) 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10s, off-grid/backup) 7.2 kVA (charge and discharge) Load Start Capability 106 A LRA for each Powerwall Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split -Phase Loads 100% Power Factor Output Range +/- 1.0 adjustable Power Factor Range (full -rated power) +/- 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiencyla 90% Warranty 10 years 'Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU MECHANICAL SPECIFICATIONS Dimensions' 1150 mm x 753 mm x147 mm (45.3 in x 29.6 in x 5.75 in) Weight' 114 kg (251.3 lbs) Mounting options Floor or wall mount 3Dimensions and weight differ slightly if manufactured before March 2019. Contact Tesla for additional information. 753 mm (29.6 in) 147 mm 1150 mm (45.3 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature - 20°C to 50°C (-4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH) Up to 100%, condensing Storage Conditions - 20°C to 30°C (-4°F to 86°F) Up to 95% RH, non -condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Seismic AC156, IEEE 693-2005 (high) Wet Location Rating Yes Powerwall Whole home backup PARTIAL HOME BACKUP Solar Optional Solar inverter T E E L n • O CM CM CM CM Sub panel Powerwall Backup loads Backup Gateway • OIZO O O O WM CM Main panel Home loads O Utility meter Grid Noise Level @ 1m < 40 dBA at 30°C (86°F) M. 1_. Ti TESLA.COM/ENERGY NA - BACKUP - 2021-06-01 TESLA.COM/ENERGY Energy Products Technical Document Product: Powerwall Last Revised: Apr. 30, 2020 POWERWALL - UL 1741 POWERWALL CONTROL SYSTEM (PCS) This document provides technical information about Powerwall, Tesla's home battery solution. The information provided in this document may be used by Authorized Resellers and Tesla Certified Installers or the electric utility itself as part of the interconnection process to understand how this product complies with UL 1741 PCS — Import Only functionality. ESS Operating Mode and Response Time The Tesla Powerwall system has been certified for to perform the ESS Operating Mode of Import Only, where it will not export active power from the battery to the Area EPS. This is the only ESS Operating Mode that is available to installers and customers. The installer and the customer can select three standard functions for the Powerwall: Backup, Solar Self -Powered, and Time of Use. All three of the functions operate within the constraint of the Import Only ESS Operating Mode specified by UL 1741 PCS. As noted on the certification documents, inadvertent export is controlled under two seconds, with an average open loop response time of 1.2 seconds and a maximum open loop response of 1.9 seconds. Components of the Power Control System Tesla Powerwall is a state-of-the-art battery system intended for residential and light commercial applications. There are two components of the Tesla Powerwall System that were certified together as a Power Control System: the Powerwall and the Backup Gateway. Powerwall 2 AC (PN: 1092170-XX-Y, 2012170-XX-Y) is an assembly that consists of lithium -ion battery cells, an isolated DC/DC converter, an integrated AC inverter and a liquid thermal management system. The battery cells inside Powerwall are the components closest to being a conventional battery; however, the installer or user is never exposed to these cells since they are electrically and physically isolated from contact by maintenance personnel or homeowners. For backup applications, the Backup Gateway (PN: 1118431-XX-Y) is used to isolate Powerwall from the grid and facilitate the powering of backed up loads. The Gateway is connected to the Powerwall via communication cables and thus functions together with the Powerwall as a complete system. Within the Backup Gateway enclosure is a microprocessor controlled power contactor, inclusive of line- and load -side voltage sensing and current measurement. In addition, the Backup Gateway contains a meter in which the CTs that measure the site net load connect to. The communication connection as well as the CT placement and their connection to the meter is diagramed in the following section. POWERWALL — UL 1741 PCS T Configuration of Power Control System — Whole and Partial Home Backup The diagrams below demonstrate the CT placement when a Tesla Powerwall system is configured for Whole Home Backup and Partial Home Backup. Detailed installation and commissioning instructions are provided in the Installation Manual. Whole Home Backup 4l,;red Com^nunication: T -a S L T. Powerwall 0▪ 1 O MN FIIIM,s.e. Main panel Backup Gateway Whole home backup 0 Main Breaker Utility meter (Service disconnect) Grid Partial Home Backup T x S L F Powerwall Wired?Communisation• in 0 WEI MD Sub panel Backup loads Hts, r'r: Backup Gateway it 0 WI 0 WIN 0 O Main panel Utility meter Home loads Grid Solar Pairing While the Tesla Powerwall system does meter the solar output if a PV system is co -located with the battery, it does not control the discharge from the PV. The presence of solar inverter does not impact the PSC Import Only functionality of the Tesla Powerwall system. CONFIDENTIAL INFORMATION — SHARED UNDER NDA ONLY Rev. 1.0 CONFIDENTIAL INFORMATION — SHARED UNDER NDA ONLY Page 2 of 2 Topic: Conductor Export Limit for Testa Backup Gateway To whom it may concern, New Power Control System (PCS) features are available for the Testa Powerwall 2 (the' Powerwall) designed to function in compliance with the 120% rule from the 2019 CEC, 2017 NEC, and 2014 NEC. One 'feature, named a "Conductor Export Limit," will curtail powet from all Powerwalls in a system to limit the total current on a conductor. In doing so, the' Conductor Export Limit is equivalent to the "power source(s) output circuit current" outlined in the requirements of 705.12 (B)(2)(3)(0) of the 2017 NEC or 2019 CEC. This feature is" outlined in the Appendix of the Installation Manual, with additional details outlined below. -Iardware & Softwarsl The Conductor Export Limit uses a pair of current transformers (CTs), with 1 CT per phase, to measure current at the controlled conductor location. Output from these CTs at measured by a dedicated meter with +/- 0.5% accuracy, and data is fed to the Backup' Gateway_.i, The Powerwall does not require additional CTs as it has a hardwired low voltage cable to the Backup Gateway. Using this connection the Powerwall and Backup Gateway coordinate' output current amperage and output current limit in real time. If the Powerwall loses this connection with the Backup Gateway, it will cease to supply power. Applicable Certifications The Testa Backup Gateway (1 & 2) is Listed to UL 1741, including the supplement for Power Control Systems (PCS).'A PCS is defined in UL 1741 as "Systems or devices which electronically lirnit or control the steady state AC currents, or DC currents, to a programmable limit or level." The Testa Backup Gateway is also Listed to UL 916, Energy Management Equipment. This UI.1 Standard covers equipment that energizes or de -energizes electrical loads to achieve the desired use of electrical power. Labels and Markings Below is an image of the field applied label on the Backup Gateway as required by the UL 1741 Supplement for PCS: PCS Controlled Current Setting: _ A The maximum output current from this system towards the main panel is controlled electronically. Refer to manufacturer's instructions for more information (Amperage to be marked by installer) Additionally as required by the UL Standard, the following label appears on the dedicated CTs used for the PCS: WARNING: THIS SENSOR IS PART OF POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH SANE TYPE AND RATING. Code Compliance Where used, the Conductor Export Limit can limit the peak amperage output to a home's main panel from the Backup Gateway. Below is one specific scenario for illustrative bums] TO 20/2 Ov SINGLE PHASE UTIITY SOLNCE 10 PCS Controk.a Cam) SetMg-°}L A i TM mmimtm output c:itmt f:I s 7; Loud, II Ms ' pond b"co"nded decnaucdly,RsfA, to lu tnan"ktcnra's n5tmi!tpns la_ more ntdii+uti (E) 20CA MAh IRSTRIBUTIOV PAIL o - • (E' ' A SERNCE DISCCNN:CT •--_ • (E) wL-eAONP —i • LOAD' (N) 200A BACRU. GATEWAY YCIER • P®A (N 125A BACKUP FEEDEA,BREAKER, — 4 (N) 2ADMBA000P LOADS PNF]80ARD LOADS Soy' • • Ca J- A BRANCH CwCUIT M 1NG EATENDED rRpl EKIS PIG YNN PANEL TO AEW BACKUP LOADS PNQ= (N) ENERGY SNRA„M STSTEN'. SOLAR 1 PV (N) a (E) Py T =- 5 L Testa, Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Testa, Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 In this scenario, the export amperage limit can be set equal to the continuous amperage allowed by the '120% rule' on the main busbar. Therefore the limit is equivalent to the "power source(s) output circuit current" outlined in the requirements of 705.12 (B)(2)(3)(b) 011 the 2017 NEC or 2019 CEC. In the above example, because the main panel is a 200A busbar with 200A service) 'disconnect, the limit is set equal to 32 amps, equivalent to a 40A breaker.] 200A main panel busbar * 120% — 200A main breaker > = 32A PCS limit * 125% Note that due to the Conductor Export Limit location on the supply side of the Backup Gateway, interconnected power sources on the 'Backup Loads Panelboard' do need to abide by 705.12 (B). In the above example, the sub panel is compliant with the 120% rule: 200A sub panel busbar * 120% — 125A sub panel breaker > = 2x30A Powerwall + 40A PV Programming of this setting is restricted to qualified Testa qualified installers, and locked behind password. This restricted access complies with the spirit of 240.6 (C) : (C) Restricted Access Adjustable -Trip Circuit Breakers. A circuit breaker(s) that has restricted access to the adjusting means shall be permitted to have an ampere rating(s) that is equal to the adjusted current setting (long-time pickup setting). Restricted access shall be defined as located behind one of the following: (1) Removable and sealable covers over the adjusting means (2) Bolted equipment enclosure doors (3) Locked doors accessible only to qualified personnel Note the PCS is not a substitute for branch -circuit overcurrent protection, but does meet the definition for supplementary overcurrent protection per the Article 100 Definitions: 0vercurrent Protective Device, Supplementary. A device intended to provide limited overcurrent protection for specific applications and utilization equipment such as luminaires and appliances. This limited protection is in addition to the protection provided in the required branch circuit by the branch circuit overcurrent protective device. (CMP-10) A circuit breaker will always be utilized to connect the Backup Gateway to the main panel, as shown in the above diagram. This circuit breaker will typically be larger than the PCS limit x 125%. Therefore, any uncontrolled power sources or uncontrolled loads (i.e. everything except the Powerwalls) will be subject to uncontrolled power flows. As such, conductors will be sized according to the circuit breaker acting as the branch -circuit overcurrent protection. Additionally, uncontrolled PV inverters must abide by 705.12 (B) at the main panel busbar assuming that the Powerwall is fully curtailed to 0 A output. 0 ♦ WaisurrImarY GATEWAY SITE NAME BACKUP CAPABILITY MODE BACKUP RESERVE GRID CODE TIME ZONE CUSTOMER VERSION NETWORK POWERWALL .J___ _ . Backup Capable Self Consumption 772% 60Hz_240V_s_ UL17415A:2019_ California America/Los_ Angeles 1.46.0•RC4 WI•FI. CELLULAR 1 PartNumber: 1092170.03•D Serial: CONDUCTOR EXPORT LIMIT 32 A 7 Inspection Verification Confirmation of Conductor Export Limit programming can be viewed from the 'Summary' home page on any phone] connected to the Testa Backup Gateway local wireless, network. See adjacent image for example.) Conclusion While the 2020 NEC has formally introduced a Powerj Control System, it allows for backfeed that exceeds the 120% rule. The Conductor Export Limit implemented with the Powerwall system is designed to function in compliance with the 120% rule from the 2019 CEC, 2017i NEC, and 2014 NEC. This Conductor Export Limit feature) is beneficial for safely connecting a larger amount o energy storage on a site, without overloading a busbar Sincerely, codecomoIiance(r tesla.com Excerpt from the 2017 NEC or 2019 CEC (emphasis added): 705.12 Point of Connection. (2) Bus or Conductor Ampere Rating. One hundred twenty-five percent of the power source output circuit current shall be used in ampacity calculations for the following: (3) Busbars. One of the methods that follows shall be used to determine the ratings of busbars in panel boards. (b) Where two sources, one a primary power source and the other another power source, are located at opposite ends of a busbar that contains loads, the sum of 125 percent of the power source(s) output circuit current and the rating of the overcurrent device protecting the busbar shall not exceed 120 percent of the ampacity of the busbar... Testa, Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 T =- 5 L Testa, Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Solar Self -Powered Mode If the home has solar on site, the customer may choose to operate their Powerwall in Solar Self - Powered Mode (also known as Self -Consumption Mode). In this mode, the Powerwall will charge from solar during normal operation and discharge to serve loads behind the customer's meter. Solar Self -Powered Mode has a user -configurable Backup Reserve. The Powerwall will reserve this energy in the event a grid outage occurs and will not use this energy for Solar Self -Power. If the Powerwall is configured for Solar Self -Powered Mode, during normal operation it will charge and discharge as follows: Load Relative to PV Generation Charge1 Discharge Load > PV Will not charge. Will discharge to serve onsite load. Load < PV Will charge from excess PV. Will not discharge. Energy from the Powerwall is not exported to the grid. The export of energy is limited to only PV generation; however, the mode tries to maintain this export of energy as close to zero as possible. The Backup Gateway monitors the power exchange with the utility through the Tesla- provided whole home meter. If export is detected, the Backup Gateway quickly commands the Powerwall to reduce discharge power or increase charge power. As Solar Self -Powered is a load -following mode of operation, a short duration inadvertent export from the Powerwall may occur when loads turn off. The magnitude of export is generally limited to the size of the largest load and the duration is less than 5 seconds. Solar Non -Export Mode In some jurisdictions, customers may choose to make the PV inverter non -export in order to go through a simpler interconnection process or due to a regulatory requirement. Solar Non -Export Mode limits the export of energy to the grid to zero for both the Powerwall and PV inverter, even if the Powerwall is fully charged and there is excess PV energy. In this subset of Solar Self - Powered, short duration inadvertent export may still occur. The interconnection process and operating criteria of non -export systems are discussed in the section on Fast Track Review for Non -Export Storage Systems. 1 The Powerwall may charge from the grid during abnormal conditions, such as when the Powerwall's state of energy is critically low. Powerwall 2 AC Utility Interconnection Support 9 Time -Based Control Mode In Time --Based Control Mode (sometimes called time -of -use or TOU mode), the Powerwall charges during off-peak times when utility rates are low, and discharges to serve onsite loads during on -peak times when utility rates are high. The on -peak and off-peak times are set by the customer in the mobile app and based on utility time of use rates. As with Solar Self -Powered Mode, Time -Based Control Mode has a user configurable Backup Reserve. The Powerwall will reserve this energy in the event a grid outage occurs and will not use it for load shifting. If the Powerwall is configured for Time -Based Control Mode, during normal operation it will charge and discharge as follows: Site Configuration Charge Discharge Standalone Will charge from the grid when utility rates are low. Will discharge to serve onsite loads when utility rates are high. Solar Onsite (Solar Only Charging) Will charge from PV when utility rates are low. Will discharge to serve onsite loads when utility rates are high. Energy from the Powerwall is not exported to the grid. The export of energy is limited to only PV generation. The Backup Gateway monitors the power exchange with the utility through the Tesla-provided whole home meter. If export from the Powerwall is detected, the Backup Gateway quickly commands the Powerwall to reduce discharge power or increase charge power. As Time -Based Control is a load -following mode of operation, a short duration inadvertent export from the Powerwall may occur when loads turn off. The magnitude of export is generally limited to the size of the largest load and the duration is less than 5 seconds. 10 Powerwall 2 AC Utility Interconnection Support CONFIDENTIAL INFORMATION - SHARED UNDER NDA ONLY CONFIDENTIAL INFORMATION - SHARED UNDER NDA ONLY 6. Frequently Asked Questions Provided below are questions commonly asked during the utility interconnection process. Device Specific Questions What is the power and energy rating of the Powerwall? • 5 kW Real Power continuous max. • 5.8 kVA Apparent Power continuous max. • 13.5 kWh usable energy. See the Powerwall datasheet for more specifications. Is the Powerwall UL 1741 certified? Yes, the Powerwall is UL 1741 certified. Can the Powerwall provide advanced inverter features? The inverter within the Powerwall is able to provide advanced inverter features. For California and Hawaii, these functions are certified to UL 1741 SA. Will the Powerwall comply with voltage and frequency ride through requirements, if applicable? Yes, if the local jurisdiction has voltage and frequency ride through requirements, the Powerwall will comply. Does the Powerwall ever export to the grid? In all modes, the system is controlled such that energy from the Powerwall is not exported to the grid. The Backup Gateway monitors the whole -home meter and controls the Powerwall such that its discharge is only consumed by onsite load. The Powerwall reduces its discharging or increases its charging to control around the net load at the point of common coupling and ensure the Powerwall does not export. As Solar Self -Powered and Time -Based Control are load - following modes of operation, a short duration inadvertent export from the Powerwall may occur due to a sudden load drop or increase in PV output. The magnitude of export is generally limited to the size of the largest load. Does the Powerwall operate in parallel with the grid? If the Powerwall is operating in Backup Mode, it does not operate in parallel with the grid. The Powerwall may charge from the grid, but discharges only when disconnected and isolated from the grid. If the Powerwall is operating in Solar Self -Powered Mode or Time -Based Control Mode, it does operate in parallel, but only as a current source. A short duration inadvertent export event may occur when loads are turned off. Details on these modes can be found in the Modes of Operation section. Powerwall 2 AC Utility Interconnection Support 11 When paired with Solar, does the Powerwall ever charge from the grid? In the US market, Powerwall is designed to charge from solar power when a solar generator is present. This is accomplished through software control that matches the Powerwall charging rate with available solar power. In exceedingly rare cases, an abnormal condition may cause a Powerwall to charge a small amount from the grid. If the unit is discharged below its operating range and is at risk of losing the ability to function, it will charge at low power briefly to maintain its ability to charge when solar energy returns. The purpose of the brief charge is to keep the Powerwall operational and does not result in usable energy in the battery. This rare abnormal condition could occur if the Powerwall is at zero charge and is unable to charge itself for an extended period of time, such as might happen if the onsite solar generator is not able to operate. Powerwall also has a feature called Storm Watch, which prepares Powerwall for a likely grid outage because of an imminent weather event. Testa monitors weather conditions and remotely enables Storm Watch in the rare occasion that grid outages are likely. When enabled, Storm Watch places Powerwall into backup mode and lifts the solar -only charging constraint for as long as the risk of outages is high. Solar -paired Powerwalls will charge themselves with solar power when available, but will also charge from the grid for a limited time, up to the Backup mode default charge rate of 3.3 kW. Powerwall owners can disable and enable Storm Watch through the Testa mobile app. 12 Powerwall 2 AC Utility Interconnection Support CONFIDENTIAL INFORMATION - SHARED UNDER NDA ONLY CONFIDENTIAL INFORMATION - SHARED UNDER NDA ONLY intertek Total Quality. Assured. Testa Inc SCOPE OF WORK UL 1741 PCS evaluation of GW2 NA model: 1232100 - followed by two numbers; followed by one letter REPORT NUMBER 104267560CRT-001 ISSUE DATE: May 20, 2020 PAGES 3 DOCUMENT CONTROL NUMBER GFT-OP-10a (6-March-2017) © 2017 INTERTEK [REVISED DATE] June 3, 2020 intertek Total Quality. Assured. LETTER REPORT Intertek Tel: (607) 753-6511 3933 US Route 11 Fax: (607) 753-1045 Cortland, NY 13045 intertek.com May 19, 2020 Intertek Report No. 104267560CRT-001 Intertek Project No. G104267560 Nirja Vakil Testa Inc. Sr. Compliance Engineer, Energy products 3500 Deer Creek Road, Palo Alto, CA 94304 Cell: 682.234.9896 Email: nvakil@tesla.com Subject: UL 1741 PCS evaluation of GW2 NA model: 1232100 - followed by two numbers; followed by one letter Dear Nirja Vakil, This letter report represents the status of our evaluation of the above referenced product according to the pertinent requirements contained in the following standards: Inverters, Converters, Controllers And Interconnection System Equipment For Use With Distributed Energy Resources [UL 1741:2010 Ed.2(Supplement SA)+R:15Feb2018] Power Control Systems (PCS) Certification Requirement Decision 3/8/2019 SUMMARY GW2 NA model: 1232100 - followed by two numbers; followed by one letter data was submitted to Intertek under satellite level 3 and found to be in compliance with the requirements in UL 1741 CRD issued on 3/8/2020. Along with the results, documentation and markings were evaluated as well. The design/ implementation of PCS between Gateway and ACPW were discussed with reviewer and it was found to be ok to have the same discharge and charge setting in PCS gateway and ACPW. The charge/ discharge settings in gateway are reflected in the ACPW, ACPW charge or discharge levels cannot be set separately. We completed testing with one ACPW and Gateway. Multiple ACPW connected to gateway architecture and design was submitted and discussed with reviewer. The delay to send command from Gateway to one powerwall and to 9th powerwall is 60ms maximum. The test summary is as below performed on one powerwall. Photovoltaic input application is not evaluated as part of this PCS evaluation. Import Only Mode. TESTING: Gateway (Import mode only) ACPW UL 1741 Clause No. Test description Comments 203.5 Step change in load test Pass 204.1.1 Export limiting from all sources Pass 204.4 Export limiting from Energy Pass This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Version: 6-March-2017 Page 2 of 3 GFT-OP-10a intertek Testa Inc Intertek Report: No: 104267560CRT-001 Total Quality. Assured. LETTER REPORT Storage Systems 204.5 Import limiting to Energy Storage Systems Pass 205.5 & 205.6 Startup / Self Check Abnormal Tests & Abnormal Maximum Self -Check Interval Test Pass 205.7 Operating Abnormal Tests Pass Completed by: Title: Signature: Date Dipesh Patel Sr. Project Engineer cf.):), Reviewed by: Title: Signature Aditya lyer Reviewer May 20, 2020 Date: May 20, 2020 Please note: this Letter Report does not represent authorization for the use of any Intertek certification marks. Revision History Date Engineer / Reviewer Description of Change 6/3/2020 Dipesh Patel DD P Changed Model number from "Backup Gateway North America 2.0" to "1232100 - followed by two numbers; followed by one letter" Aditya lyer 10- Version: 6-March-2017 Page 3 of 3 GFT-OP-10a tntertek Total Quality. Assured. Intertek 3933 US Route 11 Cortland. NY 13045 Telephone: 607-753-7311 www.intertek.com Verification of Conformity On the basis of the evaluations undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address Product(s) Tested Ratings and principal characteristics : AC Powerwall Model(s) Gateway Model(s) Brand name/ MD5 checksum Relevant Standard(s)/Specification(s) : Verification Issuing Office Name & Address Gateway Date of Test(s) Testa Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 AC Powerwall - Grid Support Utility Interactive Inverter Gateway See Amendment 1 1092170-xx-y, 2012170-xx-y 1232100 - followed by two numbers; followed by one letter Tesla / b624638a90cf Inverters, Converters, Controllers And Interconnection System Equipment For Use With Distributed Energy Resources [UL 1741:2010 Ed.2(Supplement SA)+R:15Feb2018] Power Control Systems (PCS) Certification Requirement Decision 3/8/2019 : Intertek, 3933 US Route 11, Cortland, NY 13045, USA : 11/4/2019-12/4/2019 and 4/23/2020 to 5/13/2020 Verification/Report Number(s) : 104267560CRT-001, 103879962CRT-003 NOTE: This verification is part of the full test report(s) and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. lntertek's responsibility; and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with th 'agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this,I Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved id writing by Intertek. The observations and test/inspection results referenced in this Verification ore relevant only to the sample tested/inspected. Thi$ Verification by itself does not imply that the material, product, or service is or has ever been under on Intertek certification program.) ar.1- Signature Name: Dipesh Patel Position: Sr. Project Engineer Date: 20 May 2020 Amendment 1: Backup Gateway North America 2.0 Nameplate BACKUP GATEWAY 2 PLACE TESLA PN / BARCODE LABEL HERE Confo„m to: UL STOS 67, 916, d 869A Certified to: CSA S TDS C22_2 11.2C6 & 0.19 PROTECTIVE CLASS CLASS I ENCLOSURE TYPE (UL 50) OPERATING TEMPERATURE PAN tL T'EMA TYPE 3R, RAINTIGHT 41°F fO 122°F AC INPUT / OUTPUT VOLTAGE RANGE (20) MAX CURRENT 110-240VAC 200A MAX INPUT SNORT CIRCUIT CURRENT 10kA• FREQUENCY MAXIMUM POWER 60Hz 48kW 'WHEN PROTECTED BY 700 AMPERE MAX!!UM CI ASS J FUSE THIS PANEEBOARD 1S S1$T*&E FOR LIa: ON A CIRCUIT CAPABLE OF DUI MIMIC, NOT MORE THAN 22 IA 1?l5 SYMML T RICAL AMPERES, 240 VOLTS MAXIMUM A MCI Sf>_ DOO.JMEMATION F OR ADDITIONAL SAFT TY 111 ORMA TION CAUTION: RISK OF ELECTRIC SHOCK. MIIA.TIPLE VOLTAGE SOURCES TERMINATED WITHIN. REFER SERVICING TO QUALIFIED PERSONNEL DISCONNECT EACH CIRCUIT BEFORE SERVICING. COMPARTMENT FOR SUPPLY AUTHORITY USE ONLY WARNING: ISOLATE AT SUPPLY AUTHORITY SOURCE BEFORE ENTERING THIS COMPARTMENT RISQUE DE CHOC ELECTRIQUE. PLUSIEURS SOURCES DE TENSION SONT CONNE(. I E.tS A L'I TERIEUR DE CET EQUIPMENT. CNAQUE CIRCUIT DOIT ETRE DECONNECTE INDNIDUELLEMENT AVANT INTERVENTION_ LA MAINTENANCE DOIT ETRE EFFECTUEE PAR DU PERSONNEL QUALIFIE COMPARTMENT RESERVE AU DISTRIBUTEUR D'ELECTRICITE AVERTISSEMENT: ISOLER A LA SOURCE D'ALIMENTAT)ON DU DISTRIBUTEUR AVANT D'OUVRIR CE COMPARTIMENT THE MAXIMUM OPERATING CURRENT OF THIS SYSTEM MAY BE CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURERS INSTRUCTIONS FOR MORE INFORMATION MAXIMUM PCS CONTROLLED CURRENT SETTING: 200 AMPS SUITABLE FOR USE AS SERVICE EQUIPMENT CLASS CTL PANELBOARD T=SLR www.intertek.com GFT-OP-11e (7-March-2017) www.intertek.com GFT-OP-11e (7-March-2017) Additional Gateway 2.0 NA PCS ratings Maximum PCS controlled current 200A Average Open loop response 0.96 seconds (60ms added for delay between 1 St and 9th ACPW) Maximum open loop response 1.76 seconds (60ms added for delay between 1 St and 9th ACPW) AC Powerwall Ratings Protective Class Class I Enclosure Type Type 3R Ingress Protection Battery & Power Electronics/Miring IP 67 / IP 56 Operating Temperature Range -20°C to +50 °C Derated Temperature Range +43 °C to +50 °C Inverter Topology Isolated Battery Energy 13.5 kWh Battery Type Li.lon Weight 125 Kg AC Input / Output Nominal Voltage (A.C. V) 100/120/200/208/220/230/240 Voltage Range & Max Continuous Current 90-110 V AC: 25A 114-126 V AC: 24A 180-220 V AC: 25A 198-220 V AC: 24A 198-242 V AC: 25A 207-253 V AC: 25A 228-252 V AC: 24A Frequency Range/Nominal (Hz) 50-60; 50/60 Max Continuous Power (kVA) 100 V AC: 2.5 kVA 120 V AC: 2.9 kVA (USA) 200 V AC: 5 kVA 208 V AC: 5 kVA(USA) 220 V AC: 5.5 kVA 230 V AC: 5.8 kVA 240 V AC: 5.8 kVA(USA) Power Factor Range -0.85 to +0.85 Max Output Fault Current 32 A AC Phase 200V/208V/240V; 2W +N +PE; 20; All Other Voltages; 1W +N +PE; 10 Max Supply Fault Current 10 kA AC intertek Total Quality. Assured. Revision History Intertek 3933 US Route 11 Cortland, NY 13045 Telephone: 607-753-7311 www.intertek.com Date Engineer / Reviewer Description of Change 6/3/2020 Dipesh Patel " I I ' Changed Model number from "Backup Gateway North America 2.0" to "1232100 - followed by two numbers; followed by one letter" www.intertek.com GFT-OP-1 1 a (7-March-2017) www.intertek.com G FT-OP-11 e (7-March-2017) 7 Topic: Powerwall disconnecting means to comply with 706.7 of the 2017 NEC or 2019 CEC To whom it may concern, This purpose of this letter is to clarify how the AC Powerwall 2 meets the requirements of 706.7 of the 2017 NEC or 2019 CEC for Disconnecting Means. (Note that 706.7 of the 2017 NEC is mostly equivalent to 690.71 H of the 2014 NEC though has minor differences. For jurisdictions on the 2016 CEC, the entirety of Article 706 from the 2017 NEC was incorporated into the 2016 CEC as part of the July 1st 2018 Supplement.) Manufactured for all Powerwalls, on the side of the enclosure, is a small switch. This is referred to as the "Enable" switch per the AC Powerwall 2 Installation Manual. The switch acts as a control circuit for a 240V relay integrated into the Powerwall enclosure. This internal relay is connected to the Powerwall Energy Storage System output conductors, thus when the relay is opened, the Energy Storage System ungrounded conductors are isolated from all connected circuits (load, utility, or other generation sources). 0 A circuit diagram of this disconnecting means is show below: Eaerlor Enable snitch RC aowerwall2 a Control circuit oG Falt97 AG Power Board ESS Ot put CItall Internal Relay T = S L R Testa, Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 p +852 3974 0288 f +852 3974 0287 Viewing this Enable switch and internal relay from a Code perspective, the first consideration is if it meets the Article 100 definition of a disconnecting means: D i sconnect i ng Means. A device, or group of devices, or other means by which the conductors of a circuit can be disconnected from their source of supply. (CMP-1) Device. A unit of an electrical system, other than a conductor, that carries or controls electric energy as its principal function. (CMP-1) The Enable switch and internal relay would meet the definitions for a `group of devices,' thus, this can be considered a `disconnecting means.' Now that we have confirmed this is a disconnecting means, we can look at the relevant sections of 706.7 Disconnecting Means to see if the Powerwall disconnecting means satisfies the requirements for an Energy Storage System disconnecting means: 706. 7 Disconnecting Means. (A) ESS Disconnecting Means. A disconnecting means shall be provided for all ungrounded conductors derived from an ESS. A disconnecting means shall be readily accessible and located within sight of the ESS. The AC Powerwall 2 integrated disconnecting means does disconnect all ungrounded conductors at the ESS, is readily accessible to the ESS, and located within sight of the ESS. Therefore the Powerwall product is always compliant with 706.7 (A). (E) Partitions and Distance. Where energy storage system input and output terminals are more than 1.5 m (5 ft) from connected equipment, or where the circuits from these terminals pass through a wall or partition, the installation shall comply with the following: (1) A disconnecting means shall be provided at the energy storage system end of the circuit. Fused disconnecting means or circuit breakers shall be permitted to be used. While 706.7 (E)(1) specifically mentions fuses and circuit breakers, it does not require their use. Any disconnecting means, as previously defined, are allowed. Therefore the Powerwall product on its own is always compliant with 706.7 (E)(1). Other sections of 706.7 are either not applicable, or applicable to connected equipment and secondary disconnecting means, thus are not considered here. In conclusion, based on how the AC Powerwall 2 is manufactured, the product will always meet the requirements of 706.7 for disconnecting means necessary at the Energy Storage System end of the circuit. Sincerely, codecompliance@tesla.com TEELR Testa, Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 p +852 3974 0288 f +852 3974 0287 TEL Fi POWERWALL 2 ANSI/CAN/UL 9540A:2019 Fourth Edition Test Report Supplemental Guide INTRODUCTION Testa Powerwall 2 was tested by Right Testing Lab, LLC, an ISO 17025 accredited laboratory, and witnessed by CSA Group, also ISO 17025 accredited and Nationally Recognized Testing Laboratory (NRTL). Testing was conducted in March 2021 in accordance with ANSI/CAN/UL 9540A:2019 Fourth Edition, Dated November 12, 2019 - Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems. This supplemental guide is intended to aid Authorities Having Jurisdiction (AHJs) in the application of the test results to determine compliance with applicable codes. Specifically, where building and/or fire codes require large-scale fire test data to support deviations from the minimum requirements set forth in those codes. The Testa Powerwall 2 has met the unit level performance criteria outlined in ANSI/CAN/UL 9540A when installed as follows: • The Powerwall must be installed in accordance with accompanying Powerwall 2 mounting bracket as detailed in the installation instructions. No additional non-combustible substrate is required. • For stacked installations, the Powerwall 2 stack kit accessory must be installed to provide adequate clearances for preventing unit to unit propagation. • Where applicable, a minimum clearance of 6" on the side(s) of the unit is required to prevent side -to -side propagation to adjacent units and walls. Page and Section numbers referenced from the test report are presented in bold type. For example, verification that the Testa Powerwall 2 has met the performance criteria outlined in ANSI/CAN/UL 9540A can be found on pages 4 through 6 of the report. For ease of use, this guide is arranged to follow the sequence used in the report issued by CSA Group titled UL 9540A Checklist and Test Result. The scope of the report includes the performance criteria outlined in Section 9 - Unit Level Testing of ANSI/CAN/UL 9540A:2019 Fourth Edition. The report also includes a summary of data acquired at the cell and module levels during prior testing. All Section numbers in the report are references to ANSI/CAN/UL 9540A:2019 Fourth Edition, Dated November 12, 2019. TESL n ACPW2 I TEST REPORT SUPPLEMENT 2 PRODUCT DETAILS The device under test (DUT) in the attached report is the Tesla Powerwall 2, model 3012170-XX-Y, which is also the ESS included as part of the Powerwall+ all -in -one Solar PV and Storage solution (1850000-XX-Y). Full product specifications and certifications are available on request from all Tesla authorized installers. General product details are outlined on Page 2 of the CSA Group Checklist and Test Result document. UNIT CONSTRUCTION Figure 1 below illustrates the location of the battery module with in the unit as noted on Page 3 of the report. Coolant System Power Electronics Battery Module Fig. 1 - Powerwall 2 Internal Component Layout TESL n ACPW2 I TEST REPORT SUPPLEMENT 3 SUMMARY OF RESULTS A comprehensive summary of the test results for each installation layout and test configuration is provided beginning on page 3. This section provides important information needed to determine residential and fire code compliance where reduced minimum separation distances are permitted, and where the unit is intended to be installed on a combustible substrate. Final verification that the Tesla Powerwall 2 has met the performance criteria outlined in ANSI/CAN/UL 9540A can be found beginning on page 4 through 6 of the report. This portion of the report can be used as a checklist to aid in the verification of the unit's conformance to the performance criteria for each installation configuration. In the unit level test it was demonstrated that: The Powerwall 2 mounting bracket provides adequate clearance from the wall surface on which it is mounted. Wall surface temperatures did not exceed 97°C (175°F) of temperature rise above ambient per Section 9.2.15. No additional substrate is needed. • The Powerwall 2 stack kit provides adequate clearances to prevent unit -to -unit propagation when an internal fire condition is established in an initiating unit. • The recommended clearance of 6" on the side of the Powerwall 2 unit, as specified in the installation manual, is also adequate to prevent side -to -side propagation to adjacent units. CELL AND MODULE LEVEL TESTS Pages 7 through 9 of the report provide background information and data collected during cell and module -level testing previously conducted. This data does not directly correlate to residential or fire code requirements, rather it is used to document and compare the characteristics of different cell chemistries and designs. One important value recorded is the temperature at which thermal runaway occurs. This temperature of 185.8°C is used to verify that an internal fire condition has been established during the Unit Level test. PERFORMANCE CRITERIA - CELL LEVEL Application of heat using film heater methodology did result in a thermal runaway condition, therefore module level testing was required, PERFORMANCE CRITERIA - MODULE LEVEL Application of heat using film heater methodology did result in a thermal runaway condition, and the resulting event was not contained by the module design, therefore unit level testing was required. The Powerwall is intentionally designed without a module -level enclosure. This allows vent gases to be routed in such a way that adds to the overall propagation resistance of the module, and prevents a dangerous buildup of gases that may lead to an explosion or deflagration hazard. T = E ACPW2 TEST REPORT SUPPLEMENT 4 UNIT LEVEL TEST - GENERAL Section 9 Unit Level Testing information begins on page 10 of the report. In additional to providing greater detail on the test setup and unit performance, this portion of the report can also be used as a checklist to aid in the verification of the testing laboratory's conformance to the test procedure. SAMPLE AND TEST CONFIGURATION ANSI/CAN/UL 9540A provides for several configurations: • Residential and non-residential use cases • Wall and floor mounting • Indoor and Outdoor locations The Tesla Powerwall 2 is intended to be installed in any of the configurations noted in Section 9.1, so testing is representative of each, and aligns with installation requirements established in the product installation manual. The unit level test begins with the application of heat at a specific site selected to present the greatest amount of thermal exposure to adjacent cells within the module. This application of heat must result in an internal fire condition in accordance with the module level test previously conducted. This was verified by laboratory staff using temperature data recorded during initiation of the event, compared against the cell surface temperature at thermal runaway during the cell level test. This temperature was determined to be 185.8°C. (See Section 5.1.1 and Section 9.1). Beginning with the indoor floor -mounted unit test, Section 9.2 on page 11 the report goes into more detail on each test setup and installation configuration. ACPW2 TEST REPORT SUPPLEMENT 5 UNIT LEVEL TEST - INDOOR FLOOR MOUNTED Section 9.2 begins on page 11 by outlining conformance to the physical test layout and data captured during the test. An example test layout graphic has been reproduced from ANSI/CAN/UL 9540A on page 13 for cross reference with the actual layout represented in the 3D graphic provided. A summary of the recorded dimensions is included below for clarity, along with the corresponding dimension callouts from the table on page 14. The units in this test configuration were installed according to the installation instructions using the Tesla supplied support bracket and optional stack kit. The layout was chosen to represent a worst -case installation with the minimum recommended clearances specified in the installation instructions. Pages 11 through 17 demonstrate that the test layout, wall constructions, placement of the cheesecloth indicator and instrumentation fully conformed to the test standard methodology. Dimensions (A), (B), and (E) approximately 1 in. when installed with provided brackets Figure 2 - Indoor Floor Mount Dimensions TESL n ACPW2 I TEST REPORT SUPPLEMENT 6 UNIT LEVEL TEST - OUTDOOR GROUND MOUNTED In accordance with Section 9.1.2 the indoor floor mounted test is also considered representative of outdoor ground mounted installations, with the addition of a 1-ft wide horizontal soffit instrumented in accordance with Section 9.3.3. Testa does not require an additional installation substrate, so this was omitted during testing. Pages 17 and 18 demonstrate that the test layout, wall constructions, placement of the cheesecloth indicator and instrumentation fully conformed to the test standard methodology. Dimension (0) approximately 1 in. when installed with provided brackets Figure 3 - Outdoor Ground Mount Dimensions T= S L n ACPW2 TEST REPORT SUPPLEMENT 7 UNIT LEVEL TEST - INDOOR WALL MOUNTED The indoor wall mounted test was performed in accordance with Section 9.2 except as modified by Section 9.4, which specifies a standard NFPA 286 fire test room and additional instrumentation placements. Pages 18 through 20 verify that the test layout, wall constructions, placement of the cheesecloth indicator and instrumentation fully conformed to the test standard methodology. r 6 in_ spacing between unit and target wall Figure 3 - Indoor Wall Mount Dimensions (Door opening omitted for clarity) ACPW2 TEST REPORT SUPPLEMENT 8 UNIT LEVEL TEST - OUTDOOR WALL MOUNTED The outdoor wall mounted test was performed in accordance with Section 9.2 except as modified by Section 9.5, which again adds the 1-ft wide soffit and associated instrumentation. Pages 20 through 22 verify that the test layout, wall constructions, placement of the cheesecloth indicator and instrumentation fully conformed to the test standard methodology. 6 in. spacing between unit and target wall J 1 6 in. spacing between units L J Figure 5 - Outdoor Wall Mount Dimensions TESL n ACPW2 I TEST REPORT SUPPLEMENT 9 UNIT LEVEL TEST - REPORT DETAILS Beginning on page 22, an overview table of each test is provided including a timestamped outline of observations noted. The data provided in the graphs in this section is intended to be used as a means of characterizing and comparing different ESS products in a standardized way. Another use is for evaluating non-residential installations, or ESS that exceed the aggregate quantities established in codes. The design of room construction and/or fire suppression for those systems based on this data is beyond the scope of this guidance document. We would like to answer any questions you have. Please feel free to email codecompliance@tesla.com. TESLR ACPW2 TEST REPORT SUPPLEMENT 10 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 1 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Standard(s): ANSI/CAN/UL 9540A:2019 Fourth Edition, Dated November 12, 2019 - Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems Testing Laboratory Name: CSA Group Address: Testing Program: 8501 East Pleasant Valley Road, Independence, OH 44131 USA Custom Test: Cover Letter X Note: Mark " X " in applicable test program block Testing Only If tests were performed at another facility, then described below: Testing Laboratory Name: Address: Qualification: Right Testing Lab, LLC 4767 Clark Howell Highway, Atlanta, Georgia 30349 USA A2LA 17025 Certificate Number 6364.01 Customer: Address: As above / or describe otherwise Testa 3500 Deer Creek, Palo Alto, California 94304 USA Tested By: Drew Mersereau, Right Testing Labs Name, Title N/A N/A Signature Date (YYYY-MM-DD) Reviewed by: Kim Sikorski, Certifier ® Witnessed by: Name, Title if2\(,„,-ka&Tuvi. Signature 2021-03-26 Date (YYYY-MM-DD) Version4: 01/25/2021 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 2 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V 'Product Details Test Request: ❑ Cell Level Testing ❑ Module Level Testing Unit Level Testing ❑ Installation Level Testing Manufacturer ❑ Cell: ❑ Module: /1 Unit: Testa Brand name / Trademark ❑ Cell: ❑ Module: /1 Unit: Testa Model Number ❑ Cell: ❑ Module: �I Unit: 3012170-XX-Y (used in Powerwall + 1850000- XX-Y) and 2012170-XX-Y (used in Powerwall + 1850000-XX-Y) Date of receipt of test sample(s) 2021-02-10 thru 2021-03-22 (YYYY-MM-DD) Cell/Battery Type Li -Ion Approximate Dimension (mm) (H x W X D) ❑ Cell: ❑ Module: /1 Unit: 1150 x 753 x 147 Mass (kg) ❑ Cell: ❑ Module: /1 Unit: 114 DUT Sample/Serial Number ❑ Cell: I Module: /1 Unit: DUT1, DUT2, DUT3 DUT Nominal Voltage Rating (V) ❑ Cell: ❑ Module: /1 Unit: 100/120/200/208/220/230/240 DUT Nominal Charge Capacity Rating (Ah) ❑ Cell: ❑ Module: I Unit: 404.8 Fire Mitigation Strategies: (For installation level testing) ❑ Water: Other (Specify): a N/A Additional Information Powerwall + part number 1850000-XX-Y is an integrated product offering containing Powerwall 2 and a PV inverter. UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 3 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Summary of Results Indoor/Outdoor Ground Mounted Residential Indoor Wall Mounted Residential Outdoor Wall Mounted Residential Mfg. Name and Model number Tesla Powerwall 2 (3012170-XX-Y) Number of modules in initiating BESS 1 1 1 Construction of initiating BESS per 5.3 Metallic enclosure, Compliant, 1150mm x 753mm x UL 1973 Compliant, Internal 147mm, UL9540 PCS Fire protection features N/A Module voltage corresponding to tested SOC 49.8 49.8 49.8 Thermal Runaway Initiation Method Cartridge Heaters Location of module within unit 1111 Coolant System Power Electronics Battery DRodule 11111--':- 11.11111 Observation of flaming outside unit Cheese cloth did not char or ignite as a result HRR vs Time Heat Release Data Heat Release Data Heat Release Data Separation Distances from Initiating Unit to Target Walls 6" side Less than an inch Less than an inch Less than an inch Separation Distances from Initiating Unit to Target Units 6" side unit 1" stacked unit 6" side unit 1" stacked unit 6" side unit 1" stacked unit Maximum wall surface temperatures 33.9C 29.5C 47.6C Maximum target BESS temperatures 72.9C 28.6C 30.7 Maximum ceiling/soffit surface temperatures 21.1 C 35.6C 20.5 Maximum incident heat flux on target wall surfaces and target BESS units Below detectable limits Below detectable limits Below detectable limits UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 4 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Indoor/Outdoor Ground Mounted Indoor Wall Mounted Outdoor Wall Mounted Maximum incident heat flux on target ceiling/soffit surfaces (wall mounted only) --- Below detectable limits Below detectable limits Gas Comp and Gas Comp and Gas Comp and Gas generation and composition Generation Generation Generation Peak smoke release rate 0.03m2/sec 0.05 m2/sec 0.07 m2/sec Indication of the activation of integral fire protection systems N/A Observation of flying debris and/or explosive gases None Glowing particles observed Glowing particles observed Observation of a re -ignition from thermal runaway events None Observation of sparks, electrical arcs or other electrical events None Observations of damage to initiating BESS, Target BESS, and adjacent walls, ceilings/soffits No visible damage No visible damage No visible damage Performance Criteria Flaming outside the initiating BESS unit is not observed as demonstrated by no flaming or charring of the cheesecloth indicator; Cheesecloth did not ignite or char Indoor Floor Surface temperatures of modules within the target BESS units adjacent to the initiating BESS unit do not exceed the temperature at which thermally initiated cell venting occurs, as determined in 7.3.1.8; Conformed Mounted (residential) For BESS units intended for installation in locations with combustible construction, surface temperature measurements on wall surfaces do not exceed 97°C (175°F) of temperature rise above ambient per 9.2.15; Conformed Explosion hazards are not observed, including deflagration, detonation or accumulation (to within the flammability limits in an amount that can cause a deflagration) of battery vent gases; and Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 5 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V The concentration of flammable gas does not exceed 25% LFL in air for the smallest specified room installation size. Conformed Outdoor Ground Mounted (residential) If flaming outside the unit is observed, separation distances to exposures shall be determined by greatest flame extension observed during test. Conformed Surface temperatures of modules within the target BESS units adjacent to the initiating BESS unit do not exceed the temperature at which thermally initiated cell venting occurs, as determined in 7.3.1.8; Conformed For BESS units intended for near exposures, surface temperature measurements on wall surfaces do not exceed 97°C (175°F) of temperature rise above ambient per 9.2.15; Conformed Explosion hazards are not observed, including deflagration, detonation or accumulation (to within the flammability limits in an amount that can cause a deflagration) of battery vent gases; and Conformed Heat flux in the center of the accessible means of egress2) shall not exceed 1.3 kW/m2. Conformed Indoor Wall Mounted (residential) Flaming outside the initiating BESS unit is not observed as demonstrated by no flaming or charring of the cheesecloth indicator; Cheesecloth did not char or ignite Surface temperatures of modules within the target BESS units adjacent to the initiating BESS unit do not exceed the temperature at which thermally initiated cell venting occurs, as determined in 7.3.1.8; Conformed For BESS units intended for installation in locations with combustible construction, surface temperature measurements on wall surfaces do not exceed 97°C (175°F) of temperature rise above ambient per 9.2.15; Conformed Explosion hazards are not observed, including deflagration, detonation or accumulation (to within the flammability limits in an amount that can cause a deflagration) of battery vent gases; and Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 6 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V The concentration of flammable gas does not exceed 25% LFL in air for the smallest specified room installation size. Conformed Outdoor Wall Mounted (residential) Flaming outside the initiating BESS unit is not observed as demonstrated by no flaming or charring of the cheesecloth indicator; Cheesecloth did not char or ignite Surface temperatures of modules within the target BESS units adjacent to the initiating BESS unit do not exceed the temperature at which thermally initiated cell venting occurs, as determined in 7.3.1.8; Conformed For BESS units intended for installation in locations with combustible construction, surface temperature measurements on wall surfaces do not exceed 97°C (175°F) of temperature rise above ambient per 9.2.15; Conformed Explosion hazards are not observed, including deflagration, detonation or accumulation (to within the flammability limits in an amount that can cause a deflagration) of battery vent gases. Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 7 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V ANSI/CAN/UL 9540A:2019 Fourth Edition, Dated November 12, 2019 - Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems Section Requirement Test (T) / Waive (W) / Not App. (N/A) Comments 5 General 5.1 Cell N/A Cell testing not requested by manufacturer 5.1.1 The cells associated with the BESS were tested. --- Cell testing not requested by manufacturer Cell Thermal runaway methodology: Film Heater Cell Surface temperature at gas venting (°C): 176.4 Cell Surface temperature at thermal runaway(°C): 185.8 Gas Composition: Gas Component Volume Released (After thermal runaway) (%) Methane 2.462291 C2 as Ethane 0.171503 C3 as Propane 0.01715 C4 as n-Butane 0.017254 C5 as n-Pentane 0.066551 C6 as n-Hexane 0.579244 C6+ as n-Hexane 0.308108 Propene 0.28346 Ethene 1.84865 Ethanol 0.093665 Benzene 0.184865 Toluene 0.014789 Styrene 0.005299 Carbon Dioxide 26.86704 Carbon Monoxide 41.16327 Hydrogen 25.51137 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 8 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Test (T) / Waive (W) / Not App. (N/A) Comments Total 100 LFL @ ambient: 9.55% LFL @ vent temp.: 7.95% Gas Burn Velocity: 93.7 cm/sec Pmax: 775 kPa 5.1.2 Cells associated with the --- Cell testing done to UL 1973 Appendix E BESS comply with UL 1973 See project 80054564, Cells are compliant to UL 1642 5.1.3 Cell level test report --- See 80053757 for Cell Level testing data 5.2 Module N/A See 80059532 for representative worst case Module Level testing data (1609170) 5.2.1 The module associated with --- Cell Thermal runaway methodology: Film Heater the BESS were tested. Cell Surface temperature at gas venting (°C): 176.4 Cell Surface temperature at thermal runaway(°C): 185.8 Module Heat Release Rate (kW/m2): 0.78 (peak release rate) Gas Generation was below detectable limits during module level testing. Module External Flaming and Flying Debris Hazard: Yes See 80059532 for representative worst case Module Level testing data (1609170) Modules 1609170 and 1624811 differ only in connection and number of cells. The tested module (1609170) contains a larger quantity of cells. 5.2.2 Modules associated with the --- Module is a component of UL 1973 and UL 9540 BESS comply with UL 1973 listed BESS, PowerWall 2 See Attachment 4 for certificate 5.2.3 Module level test report --- See 80059532 for representative worst case Module Level testing data (1609170) 5.3 Battery energy storage system unit T Test Conducted UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 9 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Test (T) / Waive (W) / Not App. (N/A) Comments 5.3.1 BESS were tested. --- Manufacturer Name: Testa Model: Powerwall 2 — 3012170-XX-Y (used in Powerwall + 1850000-XX-Y)Nominal Voltage: 240V (applied during testing) BESS Capacity (Ahr): 404.8 BESS Energy (kWhr): 15.3 5.3.2 BESS comply with UL 9540 --- Battery system complies with UL 1973 and UL 9540, See Attachment 4 for battery system certificate complying UL 1973 provided by manufacturer 5.3.3 Fire detection and suppression systems --- BESS do not have fire detection and suppression system 5.3.4 BESS test report --- See Unit level test section below 5.4 Flow Batteries N/A EUT is not flow battery 5.4.1 --- EUT is not flow battery 5.4.2 Flow battery comply with UL 1973 EUT is not flow battery 5.4.3 Flow battery thermal runaway determination level test report EUT is not flow battery Attachments No. Name No. of Page(s) 1 Indoor/Outdoor Ground Mounted Test Video --- 2 Indoor Wall Mounted Test Video --- 3 Outdoor Wall Mounted Test Video --- 4 UL 1973 Certificate 1 5 UL 9540 Certificate 4 5 Images 14 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 10 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V ANSI/CAN/UL 9540A:2019 Fourth Edition, Dated November 12, 2019 - Section 9 Unit Level Testing Section Requirement Comments 9 Unit Level Testing 9.1 Sample and test configuration The unit level test conducted with BESS units installed as described in the manufacturer's instructions and this section. Test Configuration: Indoor floor mounted residential use BESS Outdoor ground mounted residential use BESS Indoor wall mounted residential use BESS Outdoor wall mounted residential use BESS Unit level test required one initiating BESS unit in which an internal fire condition in accordance with the module level test is initiated and target adjacent BESS units representative of installation. Conformed Test conducted for indoor floor mounted installations with fire propagation hazards and separation distances between initiating and target units representative of the installation. Conformed Depending upon the configuration and design of the BESS (e.g. the BESS is composed of multiple separate parts within separate enclosures), this testing to determine fire characterization can be done at the battery system level. Note: The suitability of this approach shall be determined based upon the overall design of the BESS and an analysis of the battery system as representative of the overall BESS for fire characterization concerns. BESS is self-contained, all components are within the single enclosure. The initiating BESS unit shall contain components representative of a BESS unit in a complete installation. B Conformed Target BESS units shall include - the outer cabinet (if part of the design), racking, - module enclosures, and - components that retain cells components. // Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP." CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 11 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Initiating BESS sample tested within 8 hrs. after charging BESS as per manufacturer specification to obtain maximum operating state of charge. /1 Conformed Charging Procedure: CC -CV Charging Voltage (V): 49.8 Charging Current (A): 40 Charging End Condition (A): 10 Sample Number Test Configuration Final charge end time (Date and Time) Test Start time (Date and Time) DUT1 Indoor/Outd oor ground mounted 2021-03-19 12:16:37 2021-03-19 16:08:00 DUT 2 Indoor wall mounted 2021-03-22 11:37:11 2021-03-22 15:12:00 DUT 3 Outdoor wall mounted 2021-03-23 10:10:53 2021-03-23 13:05:00 BESS unit includes an integral fire suppression system. Integral fire ❑ Optional ❑ Part of ❑ DUT tested system suppression system : BESS Evaluation with Integral fire suppression without Integral fire suppression 0 DUT tested system Electronics and software controls such as the battery management system (BMS) in the BESS are not relied upon for this testing. ' Conformed 9.2 Test method — Indoor floor mounted BESS units During the test, the test room environment shall be controlled to prevent drafts that may affect test results. Temperature(°F): 72 to 74 Humidity (% RH): 40 to 48 Any access door(s) or panels on the initiating BESS unit and adjacent target BESS units closed, latched and locked at the beginning and duration of the test. a Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 12 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments The initiating BESS unit positioned adjacent to two instrumented wall sections. // Conformed Instrumented wall sections extend not less than 1.6 ft. (0.49 m) horizontally beyond the exterior of the target BESS units. // Conformed Instrumented wall sections was at least 0.61-m (2-ft) taller than the BESS unit height, but not less than 3.66 m (12 ft) in height above the bottom surface of the unit /1 Conformed The surface of the instrumented wall sections were covered with 5/8-in (16-mm) gypsum wall board and painted flat black. II Conformed The initiating BESS unit was centred underneath an appropriately sized smoke collection hood of an oxygen consumption calorimeter Conformed The light transmission measured in the calorimeter's exhaust duct of the heat release rate calorimeter. /1 Conformed The smoke release rate calculated. /1 Conformed The chemical and convective heat release rates shall be measured for the duration of the test /1 Conformed The heat release rate measurement system was calibrated using an atomized heptane diffusion burner. /1 Conformed The convective heat release rate shall be measured using 1. Thermopile, 2. Velocity probe, and 3. Type K thermocouple, located in the exhaust system of the exhaust duct /1 Conformed Following test configuration used for testing. - Installation of BESS unit with two or more rows Two rows with initiator surrounded by two instrumented walls and two target units for the indoor ground mounted test. UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 13 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments - Installation of BESS units with a single row --- Figure 8.1 Examples of potential SBA test arrangements Instrumented Instrumented Wall Section + + Wall Section m ¢ m Instrumented Wall Section C Initiating BESS Unit D Target BESS Unit 0 Initiating BESS Unit D Target BESS Unit W -.1--1.- LL a m a U uJ i u_ G + Target BESS H Target BESS Instrumen ed Wall Section Unit Unit Note: This image is not representative of the test set-up UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: Project / Network: 236698 80084072 Model: Powerwall 2 - 3012170-XX-Y Page number 14 of 45 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments ID . Location Required Value (in) Measured Value (in) A Separation distance between the initiating BESS unit and instrumented wall section behind initiating BESS unit. 1 1 B Separation distance between the target BESS unit and instrumented wall section behind the target BESS unit. 1 1 C Separation distance between the initiating BESS unit and instrumented wall section to the side of the initiating BESS unit. 6 6 D Separation distance between initiating BESS unit and target BESS unit. 6 6 E Separation distance between initiating BESS unit and target BESS unit or instrumented wall section. 1 1 F Separation distance between target BESS unit and target BESS unit or instrumented wall section. --- --- G Separation distance between target BESS unit and instrumented wall section. 6 6 H Separation distance between target BESS units. --- --- Note: The physical spacing between BESS units (both initiating and target) and adjacent walls shall be representative of the intended installation. For example, the left side of Figure 9.1 shows a layout of BESS units of two or more rows. The right side of Figure 9.1 shows a layout of BESS units of a single row, with an instrumented wall taking place of the target BESS units as the nearest potential item exposed to thermal energy from the initiating BESS unit in thermal runaway Wall surface temperature measurements collected for BESS intended for installation in locations with combustible construction. // Conformed Wall surface temperatures measured in vertical array(s) at 152-mm (6-in) intervals for the full height of the instrumented wall sections using - No. 24-gauge or smaller, - Type-K exposed junction thermocouples. // Conformed Thermocouples shall be secured to gypsum surfaces // Conformed Heat flux measured with at least two water- cooled Schmidt- Boelter gauges at the surface of each instrumented wall: // Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 15 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments a) Both are collinear with the vertical thermocouple array; Conformed, HFG are vertically collinear with TC array b) One is positioned at the elevation estimated to receive the greatest heat flux due to the thermal runaway of the initiating module; and Conformed, HFG placed at approx. 6 inches above intiating unit c) One is positioned at the elevation estimated to receive the greatest heat flux during potential propagation of thermal runaway within the initiating BESS unit. Conformed, HFG was positioned in the side of target unit facing the initiating unit Heat flux measured with at least two water- cooled Schmidt-Boelter gauges at the surface of each adjacent target BESS unit that faces the initiating BESS unit: /1 Conformed a) One is positioned at the elevation estimated to receive the greatest heat flux due to the thermal runaway of the initiating module within the initiating BESS; and Conformed, HFG was positioned in the side of target unit facing the initiating unit b) One is positioned at the elevation estimated to receive the greatest surface heat flux due to the thermal runaway of the initiating BESS. Conformed, HFG was positioned in approx. 3 ft from the front of the target unit For non-residential use BESS, heat flux measured with at least one water-cooled Schmidt-Boelter gauge positioned at the mid height of the initiating unit in the center of the accessible means of egress. /1 Conformed No. 24-gauge or smaller, Type-K exposed junction thermocouples installed to measure the temperature of the surface proximate to the cells and between the cells and exposed face of the initiating module. Each non -initiating module enclosure within the initiating BESS unit instrumented with at least one No. 24-gauge or smaller Type-K thermocouple(s) to provide data to monitor the thermal conditions within non -initiating modules. Additional thermocouples placed to account for convoluted enclosure interior geometries. 11 Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 16 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments For residential use BESS, the DUT covered with a single layer of cheese cloth ignition indicator. /1 Conformed An internal fire condition in accordance with the module level test created within a single module in the initiating BESS unit: /1 Conformed a) The position of the module selected to present the greatest thermal exposure to adjacent modules (e.g. above, below, laterally), based on the results from the module level test; and Single module unit, placement inside the module was selected to present greatest thermal exposure to surround cells. b) The setup (i.e. type, quantity and positioning) of equipment for initiating thermal runaway in the module is same as that used to initiate and propagate thermal runaway within the module level test (Section 8). i1 Conformed The composition, velocity and temperature of the initiating BESS unit vent gases measured within the calorimeter's exhaust duct. 1/ Conformed Gas composition measured using a Fourier- Transform Infrared Spectrometer with a minimum resolution of 1 cm-1 and a path length of at least 2.0 m (6.6 ft), or equivalent gas analyzer. L Conformed HFID was used. The hydrocarbon content of the vent gas shall be measured using flame ionization detection. 11 Conformed Hydrogen gas measured with a palladium- nickel thin-film solid state sensor. /1 Conformed The test shall be terminated if: a) Temperatures measured inside each module within the initiating BESS unit return to ambient temperature; /1 Conformed b) The fire propagates to adjacent units or to adjacent walls; or There was no fire propagation to adjacent units or walls c) A condition hazardous to test staff or the test facility requires mitigation. A hazardous condition was not created, such that staff or facilities were at risk For residential use systems, the gas collection data gathered in 9.2 shall be compared to the smallest room installation specified by the 11 Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 17 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments manufacturer to determine if the flammable gas collected exceeds 25% LFL in air. 9.3 Test method — Outdoor ground mounted units Outdoor ground mounted non-residential use BESS being evaluated for installation in close proximity to buildings and structures shall use the test method described in Section 9.2. /1 Conformed If intended for outdoor use only installations, following - the smoke release rate, - the convective and chemical heat release rate - velocity - temperature of the released vent gases measurement are not needed. and content, Outdoor ground mounted residential use BESS being evaluated for installation in close proximity to buildings and structures. a Section and ❑ Yes, requirement from test method described in 9.2 of UL 9540A except as noted in 9.3.3 9.3.4 considered during testing. No Heat flux measurements for the accessible means of egress. a ❑ Heatflux measured No accessible egress path Test samples installed as shown in Figure 9.2 in proximity to an instrumented wall section that is 3.66-m (12-ft) tall with a 0.3-m (1-ft) wide horizontal soffit (undersurface of the eave shown in Figure 9.2). The sample mounted on a support substrate and spaced from the wall in accordance with the minimum separation distances specified by the manufacturer. /1 D Required Measured Sample manufacturer's was Conformed — Distance of BESS from external wall by manufacturer (in.): 1 during testing (in.): 1 was flush to posterior wall, using the bracket to anchor it. No substrate used. UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 18 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Exception: If the manufacturer requires installation against non-flammable material ❑ recommended // recommended Test perfomed with manufacturer backing material Test perfomed without manufacturer backing material Figure Example of Outdoor Ground Mounted Eave Residential 9.2 Use BESS Test Arrangement I xxxxx x x Wall x X X D BESS ~ —I' x X Installation substrate SIDE su3474a X — Denotes typical thermocouple locations, specific D — Distance of ESS from external wall. Note: This is not representative of the test set-up VIEW used. positions dependent on installation details. Target BESS installed on each side of the initiating BESS in accordance with the manufacturer's installation specifications. A Conformed 9.4 Test Method — Indoor wall mounted units Indoor wall mounted BESS tested in accordance with Section 9.2, except as modified in this section. /1 Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 19 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Example Wall X - Denotes typical Figure 9.3 of Indoor Wall Mounted BESS Test Arrangement Ceiling ;: x X Ventilation opening BESS x ; I SIDE VIEW thermocouple locations, specific positions dependent on installation details The test conducted in fire test room (as per standard NFPA 286), 3.66 x 2.44 x 2.44-m (12 x 8 x 8-ft) high, with a 0.76 x 2.13-m (2-1/2 x 7-ft) high opening. /1 Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 20 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments :;,/-:ii The initiating BESS unit positioned on the wall opposite of the door opening, with the center located 1.22-m (4-ft) above the floor, and halfway between adjacent walls. Y1 Conformed Target BESS installed on the wall on each side of the initiating BESS, Conformed The wall on which the initiating and target BESS units are mounted is instrumented in accordance with Section 9.2. r Conformed The gas collection methods shall be in accordance with 9.2.. r Conformed For residential use BESS, the DUT covered with a single layer of cheese cloth ignition indicator. 11 Conformed 9.5 Test Method — Outdoor wall mounted units Outdoor wall mounted BESS tested in accordance with Section 9.2, except as /1 Conformed modified in this section. ., r i iI . UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 21 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Example of Outdoor Wall Figure Wall Mounted Eave 9.4 BESS Test Arrangement - - installation substrate I X X X X BESS .,.. X SIDE VIEW :=_,:,._i 7,a X — Denotes typical thermocouple locations, specific positions dependent on installation details. If intended for outdoor use only wall mount installations, following measurement are not needed. - the smoke release rate, - the convective and chemical heat release rate and content, - velocity - temperature of the released vent gases Test samples mounted on an instrumented wall section that is 3.66-m (12-ft) tall with a LI Conformed UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 22 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments 0.3-m (1-ft) wide horizontal soffit (undersurface of the eave shown in Figure 9.4). The initiating BESS unit positioned on the instrumented wall, with its center located 1.22- m (4-ft) above the floor, and halfway between wall edges. // Conformed Target BESS installed on the wall on each side of the initiating BESS, Conformed The wall on which the initiating and target BESS units are mounted is instrumented in accordance with Section 9.2. r Conformed For residential use BESS, the DUT covered with a single layer of cheese cloth ignition indicator. /1 Conformed 9.6 Rooftop and open garage installations Non-residential use rooftop or open garage installations BESS tested be in accordance with 9.2. If intended for rooftop and open garage use only installations, folloing measurement are not needed. - the smoke release rate, - the convective and chemical heat release rate and content, - velocity - temperature of the released vent gases Section 9 TABLE: Unit Level Test Sample No DUT 1 Type of Installation: Indoor Ground Mounted Residential Representative of Other Type of Installation: Outdoor Ground Mounted Residential Open Circuit Voltage of Initiating BESS Before Test(Vdc): 49.8 Open Circuit Voltage of Module 1 with BESS Before Test (Vdc): 49.8 Thermal runaway initiation Method: Cartridge Heaters UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: Project / Network: 236698 80084072 Model: Powerwall 2 - 3012170-XX-Y Page number 23 of 45 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments ■ Location of Initiating module within BESS: ■ Cm:dant Sy _ �.::r. PowerENeSranik5 BatteryMndute . .. - a'. - Heat Release Rate UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 80084072 Project / Network: Model: Description: Powerwall 2 - 3012170-XX-Y Page number 24 of 45 Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments • Heat Released (kW) 3 2.5 2 1.5 1 0.5 Heat Release Data -Chemcical Heat Release (kW) Convective Heat Release Rate (kW) 1.00 0.90 0.80 0.70 2 0.60v co 0.50 El v 0.40 = co 0.30 0.20 0.10 0 amok� - 1 0.00 0:00:00 0:14:24 0:28:48 0:43:12 0:57:36 1:12:00 1:26:24 1:40:48 1:55:12 2:09:36 2:24:00 Time (H:MM:SS) 0 H Observations UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: Project / Network: 236698 80084072 Model: Powerwall 2 - 3012170-XX-Y Page number 25 of 45 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Time (H:MM:SS) Observation 0:00:00 Test Start / Heater Activated 0:25:37 No Observations 0:25:35 Computer malfunction, data and video affected 0:26:45 First full vent observed, cheesecloth displaced on right side of initiating unit, small amount of srnoke observed from the top, right and left sides, of initiating unit. 0:27:46 Data acquisition system and video recording back online 0:28:26 Flash flames extending from right side, mid -height of initiating unit, flames extended behind the right -side target unit, approximately 6 inches past the right side of the target. 0:29:07 Flash flames self -extinguished and on no residual combustion observed. 0:29:52 Second vent event observed from the right side, middle of initiating unit, only smoke observed 0:30:43 Third vent event observed right side, middle of initiating unit, only smoke observed 0:31:42 Fourth vent event observed right side, middle of initiating unit, only smoke observed 0:33:26 The thermocouples located in the initiating unit are logging erroneous data due exposure of thermocouple to the D/C power of the unit or the A/C power from the heaters 0:35:16 Small amount of smoke from the initiating unit, extending vertically up the back wall. 0:39:21 Fifth vent event observed, small amount of smoke from right side of initiating unit 0:43:50 Sixth vent event observed, small amount of smoke from right side of initiating unit 0:49:24 Seventh vent event observed, small amount of smoke from right side of initiating unit, thermocouples located in the initiating unit continue to log erroneous data 0:50:00 Temperatures Dropping on all thermocouples 2:27:28 End of Test Flammable Gas Generation and Composition Data UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 80084072 Project / Network: Model: Description: Powerwall 2 - 3012170-XX-Y Page number 26 of 45 Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments 1 250 n5© Total Hydrocarbons 1:26:24 Time (1-11,AM:SS) - 1HC {liter Sfhlind[2j - iota! i Nfiiacarbarts(kers} 1:55:12 2:24:00 s 4 7 2 1 0 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: Project / Network: 236698 80084072 Model: Powerwall 2 - 3012170-XX-Y Page number 27 of 45 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments • 190 160 140 4U 78 Duct Gas Composition L� OM:041 014:24 0:28:48 0:43:12 the (H:MM:55) a:sr:36 - CV. iOPmi - Lo Ippar} - }tydrown WO - THC [ppm} 112:00 1:26:24 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 80084072 Project / Network: Model: Description: Powerwall 2 - 3012170-XX-Y Page number 28 of 45 Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Duct Flow Volume vs. Hydrocarbons t o.00 (Axial! . 900 . 060000111000000100000000000400000000— S594 U 7.00 — 50000 A E s rt 2 5.00 S-ei.00 — i �, 450Ud = — IBC (iiierstrrinute) Y C O i 4.00 4 —Total Hydrocarbons (iitersI 40o00 to 3.00 2 2.00 t.AA.SS Ai) How in Duct 30017 — (Liters/min) 1.00 0.00 ' 3000n 0:14:24 0:28148 1.1:1-1-1:0:57:36 1:12:0 1:26:24 1:40:48 1:55:12 2:09:16 7!74:00 0:n0:00 Time (H:MM:55) Activation of Integral Fire Protection System. N/A UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: Project / Network: 236698 80084072 Model: Powerwall 2 - 3012170-XX-Y Page number 29 of 45 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Smoke release rate loin — 12 0.90 0,80 10 El 0. in - 0.G0 $ n E a, °* v ca 0.50 Rate or5rnokeRelease (m'fsec) y� 6 4 E a E -Total Smoke Released (re) 0.30 - 0.20 4 FZ. 2 0.10 0.00 411.1 I 1 0 0.00.00 0:14,24 0;28:48 0;43:12 0:57:36 1112:00 1:26.24 1:40;48 1;55:12 2;09;36 2:24:00 Time (H:MM_SS) Temperature Measurement Thermocouple Location Temperature Limit (°C) Measured Maximum Temperature (°c) Ambient Temperature Before Test 25 ± 5 22.2 Max Wall Surface Temperature (6in. from ground behind unit) 97 33.9 Maximum Target BESS Temperature (side adjacent target, 20in. from bottom) 176.4 72.9 Maximum Surface Temperature of Module within Target BESS (side adjacent target, 40in. from bottom) 176.4 71.7 Maximum Ceiling or Soffit Surface Temperatures (138in. from the ground) 97 21.1 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP." CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: Project / Network: 236698 80084072 Model: Powerwall 2 - 3012170-XX-Y Page number 30 of 45 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section Requirement Comments Heat Flux Measurement Heat flux readings were below detectable limits. Indoor/Outdoor Wall Mount Heat Flux (kW) 0.07000 0.06000 0.05000 0.04000 0.03000 x CU I ' T v J.02000 171 , 0.01000 1 0.00000 o .-i N m 111 lD N 00 m 0 .--I N m U) lD N 00 m 0 c-I N m Cr O 0 0 0 0 0 0 0 0 0 ,--I c--I ,--I c--I ,--I c--I ,--I c--I ,--I c--I N N N N N o �� N N mCrV�� N N m Cr� O 61 O 61 O u1 O u1 O u1 O u1 u1 O O u1 O O u1 O 111 O 61 O m III u1 0 0 M m III Lf1 0 o O O O O O O O O O O O O ,--i ;-i ,--i rJ ,--i ‘Li ,Li Li c--1 N Time (nn:mm:ss) 1, VI lD N 00 N N N N O 61 O 0 �� N N N N N I m 0 -1 N m III lD N M m M m M m M u1 u1 O u1 O u1 O N m M m VCh11 L 1f1 0 N N N N N N N M N 00 01 0 m M m d' O 1 O 0 ,-I -� N m M m M Wall Above Initiating 1 Wall Above Initiating 2 Ceiling Right Ceiling Left Target Right Target Left Whole Assembly 30 degree angle 36-inch Egress Initiating 72-inch Egress Initiating Supplementary information:N/A UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 31 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Section 9 TABLE: Unit Level Test Sample No 111 DUT 2 Type of Installation: Indoor wall mounted residential/non- residential Representative of Other Type of Installation: --- Open Circuit Voltage of Initiating BESS Before Test(Vdc): 49.8 Thermal runaway initiation Method: Cartridge Heaters Location of Initiating module within BESS: ■ Coy !ant System F P ewar ElectreniCS 1 Battery Modute Heat Release Rate UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 32 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V n0 35 30 10 — Chentcical Heat Rele ase Sk W) —� C4MAPStINe Ii4dt Release Rate (kW) — iota! Chemical Heat Release /Ml) 0.25 0.70 OAS OA0 0:00A0 C:14.24 028:48 0:43:17 ❑:34136 I:17:06 1776:74 1:40 A8 L:55:12 2:09:36 2:24:W Time (H:MM:S$I Observations UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 33 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Time (H:MM:SS) Observation 0:00:00 Test Start / Heater Activated 0:30:00 No Observations 0:32:23 First full vent observed, cheesecloth displaced on right side of initiating unit 0:32:27 Sma!I amount of smoke observed from the top center of initiating unit. The initiating unit's casing distorting or flexing a small amount. 0:32:43 Second vent event observed from the right side of initiating unit. 0:32:47 Small amount of smoke observed from the tap center of initiating unit. 0:33:40 Third vent event observed right side and left side, middle of initiating unit. 0:33:41 Very small flash flame and ejection of glowing debris from left side, middle of initiating unit. 0:33:45 Small amount of white smoke on left side of the left target unit and right side of right target unit. 0:33:59 Fourth vent event observed right side and left side. Ejection of glowing debris from left side, middle of initiating unit. 0:34:11 Fifth vent event observed right side and left side. The initiating units casing distorting or flexing a small amount. 0:34:30 Sixth vent event observed right side and left side. The initiating unit's casing distorting or flexing a small amount. 0:34:35 Smoke increasing from the middle of initiating unit. A small charr mark has formed in the middle of th€ initiating units casing, approximately 1 inch in diameter 0:35:30 Seventh vent event observed right side and left side. The initiating unit's casing distorting or flexing a small amount. 0:35:45 Chair mark on the middle of the initiating units casing has increased to approximately 1.5 inches in diameter and extended vertically approximately 2 inches. 0:36:58 Eighth vent event observed right side and left side. The initiating unit's casing distorting or flexing a small amount. 0:38:45 Nineth vent event observed right side and left side. The initiating unit's casing distorting or flexing a small amount. 0:39:04 Tenth vent event observed right side and left side. 3:21:00 End of Test Flammable Gas Generation and Composition Data UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 34 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V 120 1.00 c 02.0 5 am 7.6 vt ry pJ 8 } 0.40 15 Total Hydrocarbons i:SS:12 Time (H: MM:SS) 2:24:00 THC (lilersfntlnute Total Hydrocarbons (hers) 2:S`1.:48 3:21:26 7 6 2 0 2:S0:24 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 35 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Gas Compasil ion (ppm j 100 90 80 70 60 50 40 30 20 10 0:00:00 0:28:48 ❑uct Gas Composition - (ppnt} - CO (ppm) ---Hydrogen (ppm) - 1 Fit (pprn) 0:57:315 1:26:24 1:55:12 2:24:00 2:52:48 3:21:36 3:50:24 Tine (H7MM_SS) UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 36 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V TotalHdracarhnns 10.00 9.00 8,00 7DR 6.00 5.00 4.00 100 200 1.00 000 %IAA 0:00:00 0:14:24 Duct Flow Volume vs. Hydrocarbons 0:18:48 0:43:12 - THC{titers/minute) Total Hydrocarbons (titers) - MASS Air How in Duct (Literslrninj 60000 55000 .50000 45000 400 )0 35000 30000 0:57:36 1:12:00 1:26:24 1:40:48 1:55:12 2:09:36 2:24:00 Titnt' jH:MM:55) Mass Air Flaw in Duct (Liters/min) Activation of Integral Fire Protection System. N/A UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 37 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Smoke release rate too 0.9E 080 0,70 w u0.60 i p i0.50 u ea s 0.40 n 6 30 0.20 Eu-o 000 6'EE:00 3 25 ?e E • 15 - Raie of Sm oke Release (m'NO .t o T^ Ts - Tom! 'Smoke Released WOo 10 M . 5 8 E1421 0:2101i8 0:43:12 0:57:6 1121:0 1:26'24 1:Go'48 1:551.2 2'04:36 21245110 Time (H:MM:55) Temperature Measurement Thermocouple Location Temperature Limit (°C) Measured Maximum Temperature (°c) Ambient Temperature Before Test 25 ± 5 20 Max Wall Surface Temperature (posterior wall, 54in. from the ground) 97 29.5 Maximum Target BESS Temperature (20in from bottom of right target) 176.4 28.6 Maximum Surface Temperature of Module within Target BESS (20in from bottom of left target) 176.4 22.4 Maximum Ceiling or Soffit Surface Temperatures (18in from wall) 97 35.6 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 38 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V • Heat Flux Measurement r 0.10000 0.09000 0.08000 0.07000 0.06000 0.05000 x 0.04000 L ▪ 0.03000 0.02000 0.01000 0.00000 Heat flux was below detectable limits Indoor Wall Mount Heat Flux (kW) O N M Lfl LO N 00 CT) 0 i--I N M Lfl lD N 00 al 0 ti N M Ln LO N. 00 al 0 N N M ▪ In LO N. 00 0l 0 0 0 0 0 0 0 0 0 0 0 ti ti N ti N ti N ti N ti N N N N N N N N N N M m M m M m M m M m 7 O L:ri O LfO LfO LfO L:ri O LfO Cr;Cr;O O O Cr; O Cr; O LflO O LfO Lfl O mfl O O Lfl O L:ri O ,fl O o otiN N m M7.7 LfLf0 0 Ni c M M .7 Ll Lf0 0NN cfl 7.7 ▪ Lf0 0 N O O O O O O O O O O O O • .--i .--i .--i Ni N N N m m m m m Time (hh:mm:ss) Wall Above Initiating 1 Ceiling Left Whole Assembly 45 degree angle Wall Above Initiating 2 Target Right 36-inch Egress Initiating - Ceiling Right - Target Left 72-inch Egress Initiating Supplementary information: --- Section 9 TABLE: Unit Level Test Sample No DUT 3 Type of Installation: Outdoor Wall Mounted Residential Representative of Other Type of Installation: --- Open Circuit Voltage of Initiating BESS Before Test(Vdc): 49.8 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 39 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Thermal runaway initiation Method: Cartridge heater Location of Initiating module within BESS: mCoolant System Power Elec[ranEcs Battery Modto l_ "'�`� , , ,. UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 40 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Heat Release Rate J 40 35 30 25 2 20 rc _ 236 200 1.50 ? x lAv c 10 5 -Chemdcal Heat Release W1 ) --- Calve ctire Heat Release Rate (kW) -Total Chemical Heat Release (Ml) 050 0 000 .0:0060 028149 0:57:36 1:26:24 1:5512 2:24108 Time (H: M M:55) Observations Time Observation ,H•MM:SS] 0:09:00 Test Start j Heater Activated 0:24:22 First full vent observed, cheesecloth displaced on right side of initiating unit and the top of the left side 0:25:55 Second full vent observed, flash flames and glowing debris ohgerved extending from right side and left side to target units, mid -height of initiating unit 0:26:14 Third full vent observed 0:26:28 Fourth full vent observed, one piece of glowing debris observed extending from right side to target unit, mid -height of initiating unit 0:26:37 Fifth full vent observed, flash flames and glowing debris observed extending from right side and left side to target units, mid -height of initiating unit 0:26:51 Sixth full vent observed with a small amount of white smoke, the initiating unit's casing distorting or flexing a small amount. 0:33:12 Seventh full vent observed with a small amount of white smoke 0:33:16 The initiating unit's casing d stoiti •ig or flexing a small amount. 0:37:37 Eighth f:Jll .. ent observed, the i litatinc .!nit's casing distorting or flexing a small amount. Charring staiti -ig t:: develop on the middle of the initiating units exterior casing. 0:37:45 A slral amount of tivhite smoke observed 0:44:33 Ninth vent event observed, the initiating unit's casing distorting or flexing a small amount. 2:27:28 End cif Test UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 41 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Flammable Gas Generation and Composition Data 1.20 020 CIO 0:28:44 Total Hydrocarbons — THC (IiSers/mirsur0l - ratal HO.ocal kson; (liters} 4 4 3 3 B c 2 2 1 i 4;57.35 1:26:24 1:5512 2:24104 2:FQ'+18 3'7.t:36 315a:4 Time I-1:MM:SS) UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 42 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Gas Comryosition (ryrym) 9© $0 70 60 50 40 30 20 10 Duct Gas Composition 1:55:12 Time (H:MM:55) 2:24:00 2:52:40 - CO (ppno) - CO Wpm] Hydr agen (pp m ] rHC(pp i) 3:21:36 3:50:24 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 43 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Total kdrocarbons 10.00 9.00 8A0 7.00 6,04 5.00 400 3.00 2.00 1,00 0.0 0:0100 0:28:48 Duct Flow Volume vs. Hydrocarbons 0:57:36 12624 1'5512 Time (F+:MM:55) - THC (Iilets/minMe) - ToWi hilitirOcarburk5(IIIerS} - MASSAit Howie Duct (Litersfmuti} 224,oa 2 52:48 3:21:3G 60000 55400 5QO00 E 45000 a a - 40000 3 35000 30000 33024 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP" CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 44 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Activation of Integral Fire Protection System. N/A Smoke release rate www 1 1.00 20 0.90 v,90 - 18 16 0.70 n E 0.60 ° 0,50 9t 2 1.0.4° ❑ E o 0.a0 0.20 0.10 —Ram-of Smoke elease(m:/set) —Total Smoke Released (m'] - 14 E 12 p 2 -10g g -8 " i6 o 1- 6 -4 2 0 1100 v 00 0-2$:4$ 0:5736 1:Th:4 1:55.:17 2:24:00 ?:,).1 1-21:3r, 3:.C1:7.1 Time (HADICSS Temperature Measurement Thermocouple Location Temperature Limit (°C) Measured Maximum Temperature (°C) Ambient Temperature Before Test 25 ± 5 20 Max Wall Surface Temperature (Wall, 54in from ground) 97 30.7 Maximum Target BESS Temperature (Left Target, 4.5in. from bottom) 176.4 47.6 Maximum Surface Temperature of Module within Target BESS (Right Target, 20in from bottom) 176.4 33.5 Maximum Ceiling or Soffit Surface Temperatures (entire soffit, 1 in, 6in, and 12in from wall) 97 20.5 UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CSA GROUP." CSA GROUP Laboratory Test Data - UL 9540A Checklist and Test Result ORIGINAL TEST DATA The results relate only to the items tested. This report shall not be reproduced, except in full, without the approval of CSA Group Testing & Certification Inc. Master Contract: 236698 Model: Powerwall 2 - 3012170-XX-Y Page number 45 of 45 Project / Network: 80084072 Description: Li -Ion BESS, up to 15.3 kWh, 120/240V Heat Flux Measurement Heat flux reading were below detectable limits Outdoor Wall Mount Heat Flux (kW) 0.10000 0.09000 0.08000 — 0.07000 0.06000 0.05000 — 0.04000 x a LT co v 0.03000 = 0.02000 { 0.01000 0.00000 o -i N M N 0 0 0 0 0 0 6 V) O Cr; O Cr; O O ,--1 ,-1 N N O O O O O O l0 N 0 0 O Cr; CO M�� O O l 00 crl 0 ,--1 N 0 0 c-I q-i g--1 O Cr; O Cr; O V) N O O O O O g--i i M N l0 ,--I g--1 ,--I g--1 N O N O 0 ,--1-I a --I N q--i q--i ,--i ,--i Time N 00 0) 0 ,--1 N M V) ,--I g--1 ,- 1 N N N N N N N O m O N O Vl O L:riO N M M�� 1-0) V) 0 0 O ,--i ,--i ,--i ,--i .--1 N N (hh:mm:ss) O r` 00 N N N Vl O c-I .-i N N N N 0) 0 r-i N m m Nl O V) N M MCf N N N II 7 1 (NJ M LO l0 r` 00 m m m m m MMMcl- O Vl O Lf) O V) O •ct V) V) 0 0 ci N N N N M M M 0) 0 V) O a --I N M M Wall Above Initiating 1 Wall Above Initiating 2 Ceiling Right Ceiling Left Target Right Target Left Whole Assembly 45 degree Egress Initiating Egress Initiating angle —36-inch 72-inch Supplementary information: --- End of Report... UL 9540A Checklist and Test Result - Version4 : 01/25/2021 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 1 of 21) GENERAL INFORMATION 01 Project Name Kaintz Residence 02 Run Title Title 24 Analysis 03 Project Location 81325 Columbus Way Madison Club CC 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 5 14 Addition Cond. Floor Area (ft2) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2) n/a 17 Fenestration Average U-factor 0.32 18 Total Cond. Floor Area (ft2) 11095 19 Glazing Percentage (%) 32.97% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available? Yes VALID ONLY FOR NEW PERMIT APPLICATIONS THROUGH DECEM BER 31, 2021 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 2 of 21) ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency' (EDR) Total2 (EDR) Efficiency' (EDR) Total2 (EDR) Standard Design 36.1 19.3 Proposed Design 35.9 11.4 0.2 7.9 RESULT: 3' COMPLIES 1: Efficiency EDR includes improvements to the building envelope 2: Total EDR includes efficiency and demand response measures 3: Building complies when efficiency and total compliance margins and more efficient equipment such as photovoltaic (PV) systems and batteries are greater than or equal to zero • Standard Design PV Capacity: 13.57 kWdc • Proposed PV kWh output exceeds proposed electricity use by 26% which may violate NEM rules. Contact local utility. Energy Use (kTDV/ft2-yr) Space Heating Space Cooling IAQ Ventilation Water Heating Self Utilization Credit Compliance Energy Total ENERGY USE SUMMARY Standard Design 4.03 73.58 1.94 2.12 n/a 81.67 Proposed Design 3.63 75.28 1.94 2.97 -2.72 81.1 Compliance Margin 0.4 -1.7 0 -0.85 2.72 0.57 Percent Improvement 9.9 -2.3 0 -40.1 n/a 0.7 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc) Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eft MI Annual Solar Access (%) 20 NA Premium Flxedmou(nt) f Microinverters false 186 Degre 5 1.05 96 100 Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 3 of 21) ENERGY DESIGN RATING BATTERY INPUTS 01 02 03 04 05 06 Control Capacity (kWh) Charging Efficiency Rate (kW)Rate (kW) Discharging Efficiency Rate (kW)Rate (kW) Basic 20 0.95 n/a 0.95 n/a REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Battery System: 20 kWh (Self Utilization Credit taken) • Cool roof • Insulation above roof deck • Insulation below roof deck • Window overhangs and/or fins • Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Building air leakage/reduced infiltration • Indoor air quality ventilation • Kitchen range hood • High R-value Spray Foam Insulation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • Pipe Insulation, All Lines Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 4 of 21) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name z Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Kaintz Residence 11095 1 5 9 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 11 1642 8 DHW Sys 1 N/A Zone 2 Conditioned HVAC System 22 1303 8 DHW Sys 1 N/A Zone 3 Conditioned HVAC System 33 1400 8 DHW Sys 1 N/A Zone 4 Conditioned HVAC System 44 1505 8 DHW Sys 1 N/A Zone 5 Conditioned HVAC System 55 1370 8 DHW Sys 1 N/A Zone 6 Conditioned HVAC System 66 944 8 DHW Sys 1 N/A Zone 7 Conditioned HVAC System 77 1047 8 DHW Sys 1 N/A Zone 8 Conditioned HVAC System 88 1169 8 DHW Sys 1 N/A Zone 9 Conditioned HVAC System 99 715 8 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftz) Window and Door Area (ft2) Tilt (deg) North Exterior Wall Zone 1 R-21 Wall1 0 Front 40 30 90 South Exterior Wall Zone 1 R-21 Wall1 180 Back 546 240 90 East Exterior Wall Zone 1 R-30 Wall 90 Left 940 267 90 Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 5 of 21) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Area (ft2) Tilt (deg) West Exterior Wall Zone 1 R-21 Wall1 270 Right 210 30 90 North Exterior Wall 2 Zone 2 R-21 Wall1 0 Front 532 357.075 90 South Exterior Wall 2 Zone 2 R-21 Wall1 180 Back 620 578.077 90 West Exterior Wall 2 Zone 2 R-21 Wall1 270 Right 156 46 90 North Exterior Wall 3 Zone 3 R-21 Wall1 0 Front 140 68 90 South Exterior Wall 3 Zone 3 R-21 Wall1 180 Back 420 201.96 90 East Exterior Wall 2 Zone 3 R-30 Wall 90 Left 2238 151.944 90 West Exterior Wall 3 Zone 3 R-21 Wall1 270 Right 560 95 90 North Exterior Wall 4 Zone 4 R-21 Wall1 0 Front 560 35 90 East Exterior Wall 3 Zone 4 R-30 Wall 90 Left 476 228 90 Wwest Exterior Wall Zone 4 R-21 Wall1 270 Right 616 80 90 West Exterior Wall 4 Zone 5 R-21 Wall1 270 Right 700 380 90 South Exterior Wall 4 Zone 6 R-21 Wall1 180 Back 84 0 90 East Exterior Wall 4 Zone 6 R-30 Wall 90 Left 910 148 90 North Exterior Wall 5 Zone 7 R-21 Wall1 0 Front 700 120 90 South Exterior Wall 5 Zone 7 R-21 Wall1 180 Back 308 0 90 Eaast Exterior Wall Zone 7 R-30 Wall 90 Left 448 9 90 West Exterior Wall 5 Zone 7 R-21 Wall1 270 Right 476 9 90 North Exterior Wall 6 Zone 8 R-21 Wall1 0 Front 350 20 90 South Exterior Wall 6 Zone 8 R-21 Wall1 180 Back 350 35 90 East Exterior Wall 5 Zone 8 R-30 Wall 90 Left 700 0 90 West Exterior Wall 6 Zone 8 R-21 Wall1 270 Right 700 264 90 North Exterior Wall 7 Zone 9 R-21 Wall1 0 Front 120 83 90 South Exterior Wall 7 Zone 9 R-21 Wall1 180 Back 240 132 90 West Exterior Wall 7 Zone 9 R-21 Wall1 270 Right 336 120 90 Roof Zone 1 R-59 Roof Attic AG Batt n/a n/a 1642 n/a n/a Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 6 of 21) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Area (ft2) Tilt (deg) Roof 2 Zone 2 R-59 Roof Attic AG Batt n/a n/a 1303 n/a n/a Roof 3 Zone 3 R-59 Roof Attic AG Batt n/a n/a 1400 n/a n/a Roof 4 Zone 4 R-59 Roof Attic AG Batt n/a n/a 1505 n/a n/a Roof 5 Zone 5 R-59 Roof Attic AG Batt n/a n/a 1370 n/a n/a Roof 6 Zone 6 R-59 Roof Attic AG Batt n/a n/a 944 n/a n/a Roof 7 Zone 7 R-59 Roof Attic AG Batt n/a n/a 1047 n/a n/a Roof 8 Zone 8 R-59 Roof Attic AG Batt n/a n/a 1169 n/a n/a Roof 9 Zone 9 R-59 Roof Attic AG Batt n/a n/a 715 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.74 0.93 No Yes Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.74 0.93 No Yes Attic Zone 3 Attic RoofZone 3 Unventilated 0 0.74 0.93 No Yes Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.74 0.93 No Yes Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.74 0.93 No Yes Attic Zone 6 Attic RoofZone 6 Unventilated 0 0.74 0.93 No Yes Attic Zone 7 Attic RoofZone 7 Unventilated 0 0.74 0.93 No Yes Attic Zone 8 Attic RoofZone 8 Unventilated 0 0.74 0.93 No Yes Attic Zone 9 Attic RoofZone 9 Unventilated 0 0.74 0.93 No Yes Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 7 of 21) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window D-04 Window North Exterior Wall Front 0 1 30 0.35 NFRC 0.21 NFRC Bug Screen Window D-03 Window South Exterior Wall Back 180 18.5 12 1 222 0.35 NFRC 0.21 NFRC Bug Screen Window W-35 Window South Exterior Wall Back 180 1 18 0.24 NFRC 0.24 NFRC Bug Screen Window W-17 Window East Exterior Wall Left 90 1 18 0.43 NFRC 0.19 NFRC Bug Screen Window W-18 Window East Exterior Wall Left 90 1 170 0.24 NFRC 0.24 NFRC Bug Screen Window W-25 Window East Exterior Wall Left 90 1 41 0.24 NFRC 0.24 NFRC Bug Screen Window W-34 Window East Exterior Wall Left 90 1 38 0.24 NFRC 0.24 NFRC Bug Screen Window D-04 2 Window West Exterior Wall Right 270 1 30 0.35 NFRC 0.21 NFRC Bug Screen Window D-01 Window North Exterior Wall 2 Front 0 6 10 1 60 0.35 NFRC 0.21 NFRC Bug Screen Window W--01 Window North Exterior Wall 2 Front 0 21.5 10 1 216'0 0.24 NFRC 0.24 NFRC Bug Screen Window W-02 Window North Exterior Wall 2 Front 0 8.1 10 1 81 0.24 NFRC 0.24 NFRC Bug Screen Window D-03 2 Window South Exterior Wall 2 Back 180 33 17.5 1 578'0 0.35 NFRC 0.21 NFRC Bug Screen Window W-31 Window West Exterior Wall 2 Right 270 23 2 1 46 0.24 NFRC 0.24 NFRC Bug Screen Window 32 Window North Exterior Wall 3 Front 0 34 2 1 68 0.24 NFRC 0.24 NFRC Bug Screen Window D-07 Window South Exterior Wall 3 Back 180 17 12 0 206'9 0.35 NFRC 0.21 NFRC Bug Screen Window D-06 Window East Exterior Wall 2 Left 90 13 12 0 1 4'9 0.35 NFRC 0.21 NFRC Bug Screen Window W-10 Window West Exterior Wall 3 Right 270 1 14 0.24 NFRC 0.24 NFRC Bug Screen Window W-11 Window West Exterior Wall 3 Right 270 1 14 0.24 NFRC 0.24 NFRC Bug Screen Window W-12 Window West Exterior Wall 3 Right 270 1 14 0.24 NFRC 0.24 NFRC Bug Screen Window W-19 Window West Exterior Wall 3 Right 270 1 14 0.24 NFRC 0.24 NFRC Bug Screen Window W-20 Window West Exterior Wall 3 Right 270 1 39 0.24 NFRC 0.24 NFRC Bug Screen Window D-40 Window East Exterior Wall 3 Left 90 1 228 0.35 NFRC 0.21 NFRC Bug Screen Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 8 of 21) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ftz) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window W-21 Window Wwest Exterior Wall Right 270 1 80 0.24 NFRC 0.24 NFRC Bug Screen Window D-02 Window West Exterior Wall 4 Right 270 38 10 1 380 0.24 NFRC 0.24 NFRC Bug Screen Window W-13 Window East Exterior Wall 4 Left 90 1 18 0.43 NFRC 0.19 NFRC Bug Screen Window W-14 Window East Exterior Wall 4 Left 90 1 56 0.43 NFRC 0.19 NFRC Bug Screen Window W-15 Window East Exterior Wall 4 Left 90 1 56 0.43 NFRC 0.19 NFRC Bug Screen Window W-16 Window East Exterior Wall 4 Left 90 1 18 0.43 NFRC 0.19 NFRC Bug Screen Window D-37 Window North Exterior Wall 5 Front 0 6 10 1 60 0.35 NFRC 0.21 NFRC Bug Screen Window D-38 Window North Exterior Wall 5 Front 0 6 10 1 60 0.35 NFRC 0.21 NFRC Bug Screen Window W-07 Window Eaast Exterior Wall Left 90 1 9 0.44 NFRC 0.19 NFRC Bug Screen Window W-09 Window West Exterior Wall 5 Right 270 1 9 0.44 NFRC 0.19 NFRC Bug Screen Window W-22 Window North Exterior Wall 6 Front 0 1 20 0.24 NFRC 0.24 NFRC Bug Screen Window D-08 Window West Exterior Wall 6 Right 270 1 72 0.59 Table 110.6-A 0.57 Table 110.6- B Bug Screen Window D-09 Window West Exterior Wall 6 Right 270 1 144 0.59 Table 110.6-A 0.57 Table 110.6- B Bug Screen Window D-10 Window West Exterior Wall 6 Right 270 1 48 0.59 Table 110.6-A 0.57 Table 110.6- B Bug Screen Window W-08 Window North Exterior Wall 7 Front 0 1 83 0.24 NFRC 0.24 NFRC Bug Screen Window W-05B Window South Exterior Wall 7 Back 180 1 132 0.24 NFRC 0.24 NFRC Bug Screen Window W-05A Window West Exterior Wall 7 Right 270 1 60 0.24 NFRC 0.24 NFRC Bug Screen Window W-04 Window West Exterior Wall 7 Right 270 1 60 0.24 NFRC 0.24 NFRC Bug Screen Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 9 of 21) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door D-32 North Exterior Wall 4 35 0.5 Door D-11 South Exterior Wall 6 35 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-03 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-01 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window W--01 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window W-02 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-03 2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window W-31 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 32 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-07 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-06 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-02 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window D-37 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window D-38 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 10 of 21) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Carpeted Fraction Heated Slab -on -Grade Zone 1 1642 80 None 100% No Slab -on -Grade 2 Zone 2 1303 40 None 100% No Slab -on -Grade 3 Zone 3 1400 30 None 100% No Slab -on -Grade 4 Zone 4 1505 0.1 None 100% No Slab -on -Grade 5 Zone 5 1370 20 None 100% No Slab -on -Grade 6 Zone 6 944 40 None 100% No Slab -on -Grade 7 Zone 7 1047 60 None 100% No Slab -on -Grade 8 Zone 8 1169 120 None 100% No Slab -on -Grade 9 Zone 9 715 20 None 100% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-21 Wall1 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C. R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco R-30 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C. R-30 R-30 / None 0.019 Inside Finish: Gypsum Board Sheathing / Insulation: R-30 Sheathing Cavity / Frame: R-30 / 2x6 Exterior Finish: 3 Coat Stucco Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 11 of 21) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C. R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic RoofZone 1 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 2 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 3 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 4 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 12 of 21) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofZone 5 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 6 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 7 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. 0. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 8 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Attic RoofZone 9 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C. R-38 None / R-8.8 0.024 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-8.8 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 13 of 21) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-59 Roof Attic AG Batt Ceilings (below attic) Wood Framed Ceiling 2x12 @ 24 in. O. C. R-21 None / None 0.035 Cavity / Frame: R-21.0 / 2x12 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Required Required 4438.0 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Pipe Insulation credit DHW Heater 1 (1) n/a None DHW Sys 1-hers-dhw WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Commercial Storage 1 75 0.82-TE 85 kBtu/hr 0 0.020000 n/a n/a n/a Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 14 of 21) WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 11 Heat pump heating cooling Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC System 22 Heat pump heating cooling Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 Setback New NA 1 1 HVAC System 33 Heat pump heating cooling Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 Setback New NA 1 1 HVAC System 44 Heat pump heating cooling Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 Setback New NA 1 1 HVAC System 55 Heat pump heating cooling Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 Setback New NA 1 1 HVAC System 66 Heat pump heating cooling Heat Pump System 6 Heat Pump System 6 HVAC Fan 6 Air Distribution System 6 Setback New NA 1 1 Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 15 of 21) SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 77 Heat pump heating cooling Heat Pump System 7 Heat Pump System 7 HVAC Fan 7 Air Distribution System 7 Setback New NA 1 1 HVAC System 88 Heat pump heating cooling Heat Pump System 8 Heat Pump System 8 HVAC Fan 8 Air Distribution System 8 Setback New NA 1 1 HVAC System 99 Heat pump heating cooling Heat Pump System 9 Heat Pump System 9 HVAC Fan 9 Air Distribution System 9 Setback New NA 1 1 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi speed Heat Pump System 1-hers-htpump Heat Pump System 2 Central split HP 1 11 59000 49500 21 13 Not Zonal Multi speed Heat Pump System 2-hers-htpump Heat Pump System 3 Central split HP 1 10.5 45000 42500 22 13 Not Zonal Multi speed Heat Pump System 3-hers-htpump Heat Pump System 4 Central split HP 1 10.5 45000 42500 22 13 Not Zonal Multi speed Heat Pump System 4-hers-htpump Heat Pump System 5 Central split HP 1 10.5 45000 42500 22 13 Not Zonal Multi speed Heat Pump System 5-hers-htpump Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 16 of 21) HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 6 Central split HP 1 11.5 33400 31730 20 15.5 Not Zonal Multi speed Heat Pump System 6-hers-htpump Heat Pump System 7 Central split HP 1 10.5 45000 42500 22 13 Not Zonal Multi speed Heat Pump System 7-hers-htpump Heat Pump System 8 Central split HP 1 8.3 34800 27300 19.3 12.3 Not Zonal Single Speed Heat Pump System 8-hers-htpump Heat Pump System 9 Central split HP 1 11.5 33400 31730 20 13.5 Not Zonal Multi speed Heat Pump System 9-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1 hers htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 2-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 3-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 4-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 5-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 6 hers htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 7 hers htpump Required 350 Required Required Yes Yes Yes Yes Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 17 of 21) HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 8-hers-htpump Required 350 Required Required No Yes Yes Yes Heat Pump System 9 hers htpump Required 350 Required Required Yes Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Ducts Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a No Bass Duct Air Distribution System 1-hers-dist Air Distribution System 2 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 2-hers-dist Air Distribution System 3 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 3-hers-dist Air Distribution System 4 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 4-hers-dist Air Distribution System 5 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 5-hers-dist Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provide : CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 18 of 21) HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Ducts Duct Leakage HERS Verification Air Distribution System 6 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 6-hers-dist Air Distribution System 7 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 7-hers-dist Air Distribution System 8 Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 8-hers-dist Air Distribution System 9 Outdoor locations Non -Verified R-8 R-8 Outside Outside n/a n/a No Bypass Duct Air Distribution System 9-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design g Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 2-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 19 of 21) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage TargetDucts ( ) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Low -leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 3-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 4-hers-dist Yes 3.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 5-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 6-hers-dist Yes 3.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 7-hers-dist Yes 3.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 8-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No Air Distribution System 9-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.38 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.38 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.28 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.28 HVAC Fan 4-hers-fan Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribdl9x CF1R-PRF-01E (Page 20 of 21) HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 5 HVAC Fan 0.28 HVAC Fan 5-hers-fan HVAC Fan 6 HVAC Fan 0.23 HVAC Fan 6-hers-fan HVAC Fan 7 HVAC Fan 0.28 HVAC Fan 7-hers-fan HVAC Fan 8 HVAC Fan 0.58 HVAC Fan 8-hers-fan HVAC Fan 9 HVAC Fan 0.23 HVAC Fan 9-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.38 HVAC Fan 2-hers-fan Required 0.38 HVAC Fan 3-hers-fan Required 0.28 HVAC Fan 4-hers-fan Required 0.28 HVAC Fan 5-hers-fan Required 0.28 HVAC Fan 6-hers-fan Required 0.23 HVAC Fan 7-hers-fan Required 0.28 HVAC Fan 8-hers-fan Required 0.58 HVAC Fan 9-hers-fan Required 0.23 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 365 0.25 Default 0 n/a Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Kaintz Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-12-31T13:25:49-08:00 Input File Name: Kaintz Residence.ribd19x CF1R-PRF-01E (Page 21 of 21) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Butch White Documentation Author Signature: Bu. -C.A'v White, Company: Breeze Air Conditioning LLC Signature Date: 12/31/2022 Address: 75-145 Street Charles Place CEA/ HERS Certification Identification (If applicable): City/State/Zip: Palm Desert, CA 92211 Phone: (760) 346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State 1. I am eligible under Division 3 of the Business and Professions 2. I certify that the energy features and performance specifications 3. The building design features or system design features identified calculations, plans and specifications submitted to the enforcement of California: Code to accept responsibility for the building design identified on this Certificate identified on this Certificate of Compliance conform to the requirements on this Certificate of Compliance are consistent with the information provided agency for approval with this building permit application. of Compliance. of Title 24, Part 1 and Part 6 of the California Code of Regulations. on other applicable compliance documents, worksheets, Responsible Designer Name: Butch White Responsible Designer Signature: 13 utc3qi l: e, Company: Breeze Air Conditioning LLC Date Signed: 12/31/2022 Address: 75-145 Street Charles Place License: 1045015 City/State/Zip: Palm Desert, CA 92211 Phone: (760) 346-0855 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010206032A-000-000-0000000-0000 Registration Date/Time: 12/31/2022 13:26 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-12-31 13:29:00 Schema Version: rev 20200101 Laboratory Tested 2,359 lbs Vertical Pullouts 80S lbs Side Lateral Pullout! Serrated base grips the roof deck to prevent the base horn moving while installing the lag bolt professiona SOLAR products* (805) 486-4700 (805) 486-4799—lux 1551 5. Rose Ave. Oxnard, CA 93033 View ma re info ott our website a www.prosolar.com Profasslupvl Sabi Prodotts, Inc, Fehraarr FastJack Patent #6,3&0,491 Flashable Roof Stanchion The patented design of the FastJack' is the most inn Motive, efficient and cast -effective tool of it's kind! The FosilacV has been laboratory tested to provide 2,359 pounds of strength using only a single lag bolt (included)! Four Sizes Available! 3" High Parl## FJ-300-18 For low profile installations using Oaley® fleshings (for composition shingle roof -taps) 4-1/2" High Parr# FJ-450-18 For installations using standard fleshings (for composition & flat rooftops) 6" High Park# FJ-600-18 For standard fleshings (for flat tile rooftops) 7-1/2" High Part# FJ-750-18 For standard fleshings (sized for 5-curve tile roofs and/or double flushed installations) ,The Fasi Jorkhr design is covered under Put. #6,360,491 Using lea 5/16" x 31/2" rug Bolt All FastJodk° attachments are sold in heavy duty reclosable boxes which allow for easy storage and handling Box includes: (10) 1" din. Aluminum Posts (10) Aluminum Bases (18) 3/8" x 3/4" SS Bolts Benefits of the flastkackT • Removable post makes inslallalian on existing reefs/retrofil quick and easy (refer to the illustration to she right) ▪ Patented design locates the lag hall directly under the stanchion providing superior strength values • Fost & nosy 10 install —saves time and lebor rusts • Precision machined from extruded domino', there ore no welds to corrode or break • Significonlly lighter than steel for installer convenience and reduced shipping costs. • [merit el dFIFI guide insures perfect pilot holes every time—rsinimizes the possibility of splitting roof rollers • Rose design allows virtually any roof flashing to install fiat on the roof deck Email us for. more information rosolar@prosolar.com UL2703` FastJackI FJ-300.18 For aata'Cr style f%oshings Fastlack`"-' FJ-450.18 For stondord meld (lashings (18) 3j8" SS Flat Washers (18) 5/16" x 3-1/2" Lag Bolts Easy installation of fleshings an existing roof -taps Standard & Oatey Fleshings slip over the base and under the delicate shingle 5116"x3.112" Lag Bolt ; Threaded Fast Jack Base 318" SS 318"x314" Flatwasher SS ltex �oJt //Thepost can be installed through the tap of the flashing Easy Installation: (See FastJack® installation video at: www.prosokar.com) Carbide recommende. to break through roof material befare 5 drifting iStep 1: Drill Pilot hole in Rafter sing integrated drill aide Step 4: Temporarily hold post in place by inserting upwards into flashing 142. !Illittep 2: Install base usmg included log into pilot hole Step 5: Insert flashing, h aligning post and base «i Professionut SoinrFro-km Inc. February HIS. Falb& Qs5 ha *toed tidemark and soared under Pailk.360,441 Step 3: Cut through shingles for flashing (flashing template illustrated below) Step 6: Tighten post onto base Flashing Template Available for Oatey (Pictured) and standard flashittgs. Makes cutting in a perfect flashing easy! HEAT ALARM `aHD6135FB 13 5 ° FIXED & RATE OF RISE Microprocessor controlled -Features Fixed Rate and Rate of Rise temperature sensing - allows unit to alarm prior to reaching the fixed temperature setting of 135° F. IR REMOTE CONTROL Can test or silence thealamt with most household remote controls,. LATCHING ALARM INDICATOR Remembers which unit initiated an alum. SINGLE BUTTON TEST/SILENCE Silences and tests alarm with a single button. TWO LOCKING FEATURES Pins are provided to lock battery drawer and/or alarm to base. Perfect for apartment, dormitory or hotel applications. IONIZATION Listed to UL539 Standard BRIC THE PROFESSIONAL STANDARD 120VAC, 60Hz Wire -in with 9V Battery Backup Description: The BRK Brands, Inc. Model Number HD6135FB is a wire -in, 120V AC 60Hz single and/or multiple station heat alarm designed to supplement smoke alarms in residential and institutional applications including sleeping rooms of hospitals, hotels, motels, dormitories and other multi -family dwellings as defined in standard NFPA 101. Models HD6135FB complies with UL539, CSFI1I, NFPA 72, HUD, FHA and other agencies that model their codes after the above agencies. They meet building codes where AC and AC/DC with Silence heat alarms are required. The alarms are interconnectable with up to 18 devices, of which 12 can be smoke alarms. This heat alarm is not a smoke alarm nor has it been designated a life safety device. BRK Electronics HD6135FB is designed to give reliable early warning of heat from fire. It is recommended for garages, crawl spaces, bathrooms, kitchens, laundry rooms or other applications not suitable for smoke alarm installations. It features exclusive IR remote control test/silence that can be activated by most household remote controls. The unit contains a thermistor that senses heat and will alarm when either the temperature reaches 135°F or when a rate of rise of 15°F/minute is sensed by the microprocessor. This feature enables a more rapid response to a potential fire. The unit has an 85dB hom, a 9V battery backup power supply, an easy access side -load battery drawer. This alarm features Warm Latch: Easily identifies initiating alarm even after alarm condition has subsided; Low Battery Silence: Temporarily silence the low battery chirp far up to eight hours: Alarm Silence: Silence alarm for several minutes. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a Quick -Connect wiring harness. Installation is quick, easy and cost effective. 1 1! ri-jkcola 1 ARCHITECTURAL AND ENGINEERING SPEC The heat alarm shall be a BRK Model 11D6135FB and shall provide at a minimum the following features and functions: 1. A thermistor and microprocessor capable of sensing and alarming at a 135°F fixed temperature level and a 15°F/min. rate of rise temperaaure change. 2. The unit shall be capable of self restoring. 3. Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid state pieta horn rated at 85dR aloft 4. A visual green LED power -on indicator to confirm unit is receiving power or is in alarm. 5. A full function test button should check at alarm functions by simulating a smoke conditkn, causing the unit to alarm. 6. Silence feature - Temporarily silence unwanted nuisance alarms. 7. An infrared remote (IR) feature to test and/or silence the alarm with most household remote controls. 8. Two Locking features - tamper resistant locking pins That lock battery drawer andfor alarm to mounting bracket, 9. The unit shall be capable of operating between -10°F (-23°C) and 100°F (38°C) and relative humidity between 10% and 90%. 10. The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for true alarm alignment. 11. The unit shal I have a plug in connector and be capable of interconnection of up to 18 alarms, 12 of which can be smoke alarms. 12. The unit shall at a minimum meet the requirements of UL539, CSFM, NFPA 72, NFPA 101,1CC INSTALLATION OF ALARM Installation of this heat alarm must conform to all local electrical codes and Artcle 760 of the National ilectrical Code (NFPA 70) B and NFPA 72. Interconnected units must meet the following 7a requirements: Total length of wire interconnecting units should be - less than 1000 feet, be #18 gauge or larger and be rated at least 300V. It is recommended that all units be on the same fuse or circuit breaker. If local codes do not permit, be sure the neutral wire is cemmon to both phases. THE PARTS OF THIS HEAT ALARM � r 1. Mounting bracket 2. Mounting Slots 3. Locking Pins 4, Hot Owls) AC Wire 5, Nuelrar (White) AC Wire 8. Interconnect (Orange) Wire 7. Battery Drawer Latch 8. Denary Drawer - Irxwsll 9V battery here 9_ Quick -Corinne! Plug 54321 A. Unswltchod 120VAC Et. Hz source 6. To addilr°nal unite; Maximum = t 5 total (Maximum 12 Smoke Alcamo) T. SmokeAlerrn 2. Calling or Wall a. Power Connector 4. Wire Nut 5. Junction Box 8_ Neutral Wire ('White) 7. Intel w,ii RatnaLt Wire (Orange) 8. Hot Wire (blade) TECHNICAL SPECS M_ Alarm Dimensions: 5.4" dia x Weight; 7.3 oz Operating Voltage: 120V AC 60Hz w/ 9V battery backup Operating Current: -05 amps (standbylalarm) Temperature Range: -10°F (-23°C) to 100°F (36°C) Humidity Range: 10% to 90% relative humidity (RH) Audio Warm: 85dB at 10 feet Test/Silence: Electronically simulates alarm condition, causing the unit to alarm Press and hold testlsilence button Alarm Reset: Automatic when temperature coals below 130°F Intenconnectlans: Up to 18 units of First Alert or BRK Smoke, CO and Heat Alarms. Maximum of 12 smoke alarms. See user's manual for details. Heat Sensor; Thernlistor Indicator Lights/Sounds: AC Power: Constant Green LED DC Power: Intermittent Green LED Local Alarm: Red LED flashes rapidly, audio alarm Remote Alarm; Red LED out. Latching Alarm: Red LED flashes after local alarm stops Lasting: Listed to UL539 Standard SHIPPING SPECS: Individual Carton Dimensions Weight Cube UPC 5.501L x 2.50'W x 5.63"H 0.50 lbs. 0.045 ft3 0 29054 50810 2 Master Carlon Dimensions Master Pack Weight Cube: 12015; 16.81"Lx10.31"wx8.251H 12 6.3 lbs. 0.63 ft3 100 29054 50810 9 Pallet Information Cases per Layer Number of Layers: Cases per Pallet Units per Pallet: Cubs; Weight: 10 7 70 840 54.7 ft3 550 lbs. BRK TH!PRQF!$$SQNAk$TaPRARrJ brkelectranics.com 02009 BRK Brands, Inc. a Darden Came n Company NYSE: JAHf 3901 Ube Sheet Road Aurora, C -8122 All rights reserved First Alert isa registered trademark of Ihs Fxst Alert -Trust BRK is a registetei fr dernark of BRK Brands, Inc. CM2944 SOLARMOUNT :EUNIRAC SOLARMOUNT defined the standard in solar racking. Features are designed to get installers off the roof faster. Our grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Systems can be configured with standard or light rail to meet your design requirements at the lowest cost possible. The superior aesthetics package provides a streamlined clean edge for enhanced curb appeal. with no special brackets required for installation. Now Featuring: THE NEW FACE OF SOLAR RACKING Superior Aesthetics Package NO*P- [e] er phase FRONT TRIM END CAPS �'..-• .r ,.1 --MO- 1 LOSE ALL OF THE COPPER & LUGS SMALL IS THE NEXT NEW BIG THING ENHANCED DESIGN &LAYOUT TOOLS System grouodingthrorigh Enphase misminyertetsandtrunkcables Light Rail is Fully Compatible with all SM Components Featuring Googfe telap Capabilities within U-Builder FAST INSTALLATION. SUPERIOR AESTHETICS IIR[11111IF111111li111F11p1111111111111il11111 Ili ii111,1111 ii]Iililllgll+l 1111 Rlli 1111111111 iril RI1I I1I1I II IFI II 111111i ililRI I11 IIIII I111I 11111 i1pi!Pgllll 1111111111 Ip111111+111PF{IIII I111 Rlli 11111 RIIIJPr-0Iii11q on 11I111pl!Hi pill illiilili i1111 IIIIIJ111111II 11111 IL111111i lilii1illflillilillll111111Fi11111111111 oil+lillllillr611l 11111 OPTIMIZED COMPONENTS • VERSATILITY • DESIGN TOOLS • QUALITY PROVIDER SOLARMOUNT OPTIMIZED COMPONENTS INTEGRATED BONDING & PRE -ASSEMBLED PARTS Components are pro assembled and optimized to reduce installation steps and save labor time.Ournew grounding & bonding process etiminatescopper wire and grounding straps et bonding jumpers to reduce costs, Utilize the rnicroinverlor moron with awue management clip for an easier installation. VERSATILITY ONE PRODUCT - MANY APPLICATIONS Quickly set modules flush to the roof or a1 a desired tilt angle. Change module enenfaiion to portraitor landscape while securing a large variety of framed modules on flat. low slope or steep pitched roots. Available in mill, clnarand dark anodized finishes to outperform your projeels financial and aesthetic aspirations AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE Cleanup, a bill ei materials is lust a feu clicks away with U-Builder, a powerful online tool that streamlines the processor designing code compliant solar mounting system. Save lime by creating a uaerprolile.and recall preferences and projects automatically when you tog in. You will enjoy the ability to share projects with customers. there's nn need to print results and send le a distributor, just click and share. KWIC &GROUNDING u L2703 KWIC .CLOQOINO SYSTEM FIRE CtASSIRCATION :PUNIRAC INTEGRATED BONDING SPLICE BAR INTEGRATED BONDING MICROINVERTER MOUNT wl WIRE MANAGEMENT INTEGRATED BONDING MIDCLAMP INTEGRATED BONDING L-FOOT wl T-BOLT UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT UNMATCHED EXPERIENCE CERTIFIED QUALITY TECHNICAL SUPPORT Uniracs leclink:al support team is dedicated to ansvreling questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process, ENGINEERING EXCELLENCE CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO ceiIitications for 9001-2008. 11001:2004 and DEUS 18001-2001, which means we deliyer the highest standards for hi, form. and function. These certifications deraunstrate our excellence and commitment to first class husiness practices 1111 DESIGN TOOLS PERMIT aoeuMENTATION BANKABLE WARRANTY Dont leave your project to chance. Unitas has the financial strength to back our products and reduce your risk. Nave peace ul mind knowing you are receiwatg pmducts of sceplional quality. SOIA#tMtXJNL is covered by a 10 year limited product warranty and a 5 year limited hnish warranty. PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN Figze'Vn1-F INtWU0'nai P7 S structural ENGINEERS March 31, 2020 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac- Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail Version PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/5E1 7-05, ASCE/5EI 7-10, ASCE/SEI 7-16 2. 2019 California Building Code, by California Building Standards Commission. 3. 2006-2018 International Building Code, by International Code Council, Inc- w/ Provisions from SEAOC PV-2 2017. 4. 2006-2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 5- AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Clearance: Tolerance(s): Installation Orientation: Maximum cantilever length is L/3, where "L" is the span noted in the U-Builder online tool. 2" to 10" clearfrom top of roof to top of PV panel. 1.0" tolerance for any specified dimension in this report is allowed for installation. See SOIARMOUNT Rail Flush Installation Guide. Landscape - PV Panel Tong dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. P7 S structural ENGINEERS Components and Cladding Roof Zones; The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kit is 1.0, 4) Array Edge Factor YE =1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 71Attachment spacing(s) apply to a seismic design category E or Bess. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and ▪ Understand and determine the appropriate values far all input parameters of the U-Builder software. This letter certifies that the Unirac 5M 50tARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed an the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions an the above, do not hesitate to call. Prepared by: PZSE, Inc. — structural Engineers Roseville, CA 1478 Stone Point Drive, Suile 190, Roseville, CA 95661 - 916_961.3960 916.961.3965 www.pzse.com 1 of 2 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916,961.3960 916.961.3965 . www.pzse.com 2of2 McPherson. Erigirteerin.g Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Kaintz Residence 81325 Columbus Way La Qu i nta, CA 92253 Digitally sealed by RJM on 2/6/23 Designed in Accordance with CBC 2022, ASCE 7-10, BSOL2022-0591 Date: 2/6/23 Job #: 22-14064 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group CI TY OF LA QU N TA BULDNGDVISCAN REVI EVED FOR CCCE CCLI AV CE BY: Deisy Mendez E: 0311412423 20.5kW PV SOLAR - (50) 410W PANASONIC EVPV410 MODULES + TESLA BATTERY BACKUP SYSTEM 14KWH. [1000SF] 2022 CALIFORNIA ELECTRICAL CODE. 1 of 7 2/6/2023 9:40 AM ©McPherson Engineering McPherson Engineering By: F.A. Date: 2/6/23 Table Of Contents Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 2 of 7 2/6/2023 9:40 AM ©McPherson Engineering McPherson Engineering By: F.A. _NL Date: 2/6/23 Location: 81325 Columbus Way La Quinta, CA 92253 Existing Structure Info: Number of Stories = Aroof = A3rd flr = A2nd flr = Site Properties: 1 12000 sq. ft. 0 sq. ft. 0 sq. ft. Lattitude = 33.670262 Longitude =-116.245688 Ss = 1.560 Si = 0.641 Exposure Category = C Ult. Wind Speed = 130 m.p.h. P.V. Array Info: Project Info Roof Square Footage Third Floor Square Footage (if applicable) Second Floor Square Footage (if applicable) Model = EVPV380 Height of Panel = 67.80 in. Width of Panel = 40.00 in. Area of Panel = 18.8 ft.2 Number of New Panels = 50 Number of Exis. Panels = 0 Total Area of Array = 941.7 ft.2 Spacing of Anchors = 4.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 0-7 deg 3 of 7 2/6/2023 9:40 AM ©McPherson Engineering McPherson Engineering By: F.A. _NE Date: 2/6/23 Existing Loads: Roof Design Loads: Roofing = Sheathing = Framing = Misc = DLr1 = Ceiling = DLr2 = 2.0 p.s.f. 1.5 p.s.f. 1.5 p.s.f. 1.0 p.s.f. 6.0 p.s.f. 2.0 p.s.f. 8.0 p.s.f. LLr = 20.0 p.s.f. SL = 0.0 p.s.f. Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f. Sheathing = 2.2 p.s.f. Framing = 2.0 p.s.f. Interior Partitions = 15.0 p.s.f. Ceiling = 5.0 p.s.f. Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f. Proposed Loads: Gravity Loads TPO roofing 1/2" Plywood 2x Rafter/Truss Framing Roofing Dead Load (applied to top of rafters/trusses only) Drywall and 2x framing Total Existing Roof Dead Load Roof Live Load (Per C.B.C, Table 1607.1) Snow Load Weight of floor finish 3/4" plywood 2x framing or manufactured floor truss 2x framed walls with drywall finish each side Drywall ceiling finish below Total Existing Floor Dead Load Panels = 2.8 p.s.f. weight of panels including rack system DLr1_proposed = 8.8 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 10.8 p.s.f. Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) = Total Proposed Roof Load Wprop = (DLO + LLr) (Aroof - Aarray) + (DLr1_proposed+ LLr_proposed) (Aarray) = Proposed Load Demand Wprop -Wex Wex = -5.20% 312.0 kips 295.8 kips TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! 4 of 7 2/6/2023 9:40 AM ©McPherson Engineering Seismic Design Parameters Risk Category = 2 Site Class = D Ss = 1.56 S1 = 0.64 S.D.C. = D Fa = 1.20 Fv = 1.70 SMS = SDS Fa = 1.87 SM1 = SD1 Fv = 1.09 SDS = 2/3 (SMS) = 1.25 SD1 = 2/3 (SM1) = 0.73 McPherson Engineering By: F.A. Date: 2/6/23 Lateral Loads Per Table 1-5-1 R = 6.5 Per 11.4.2 le = 1 Short Period P.G.A. 1-Sec Period P.G.A. Seismic Design Category Per 11.6 Site Coefficient per Table 11.4-1 Site Coefficient per Table 11.4-2 Short Period M.C.E. Per Eq. 11.4-1 1-Sec Period M.C.E. Per Eq. 11.4-2 Short Period Design Parameter Per Eq 11.4-3 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) T = Ct (hn)x hn = 15 ft Ct = 0.02 x = 0.75 T = 0.15 sec TL = 8 sec Seismic Response Coefficient (Per 12.8.1.1) Cs = (SDS le)/R = 0.19 Cs1 = 1.5*(SD1 le)/R T = 1.10 Cs2 = 0.01 Cs2 = 0.044 SDS le = 0.05 Cs3 = 0.5 Si le/R = 0.05 Cs = 0.19 Check Additional Base Shear Wexisting = Wpaneis = Vexisting = Cs Wexisting = Vpaneis = Cs Wpanels = Vpanels Vexisting Response Modification Factor (Table 12-2.1) Seismic Importance Factor (Table 1.5-2) ASCE 7-16 Supplement #1 Tables used for Fa and Fv (note: section 11.4.8 Exception #2 calc used) per Eq. 12.8-7 (per table 12.8-2) (per table 12.8-2) Approximate Fundamental Period Long -Period Transition Period per Figure 22-12 Seismic Response Coefficient Per Eq. 12.8-2 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T 5 TL Min. Seismic Response Coefficient Per Eq. 12.8-5 Min. Seismic Response Coefficient Per Eq. 12.8-5 Min. Seismic Response Coefficient Per Eq. 12.8-6 if Si >_ 0.6g Design Seismic Coefficient 96.0 kips 2.6 kips 18.4 kips 0.5 kips 2.73% < 10% Weight of Existing Structure Weight of Proposed Panels Roof Level Shear of Existing Structure Additional Roof Level Shear of Proposed Panels PER I.E.B.C. 1103.2 Exception #2, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 5 of 7 2/6/2023 9:40 AM ©McPherson Engineering McPherson Engineering By: F.A. Date: 2/6/23 Wind Uplift Anchorage Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vuit = 130 mph KZt = 1.00 (sec 26.8.2) h = 15 ft Exposure Category = C KZ = 0.85 (sec 26.10.1) Roof Zone = 2 Kd = 0.85 (sec 26.6) Roof 0 = 0-7 deg Ke = 1.00 (sec 26.9) qh = 0.00256 KZ KZt Kd Ke V qh = 31.26 (eq. 26.10-1) GPp = -2 uplift YE = 1.5 (sec 29.4.4) Ya = 0.78 (fig 29.4-8) Flush Mounted Panels - ASCE Section Flat Roof Panels - ASCE Section 29.4.3 29.4.4 (where applicable) (where applicable) YE = 1.5 FIG 29.4-7) vc = 0.94 (fig 29.4-7) hpt = 0 Ya = 0.78 (fig 29.4-8) Yp = 0.9 (fig 29.4-7) w = 7.00 deg (panel tilt) GPp = -2 uplift GCrn, = 2 uplift P = qh (GPp) YE Ya (eq 29.4-7) p = -73.0 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W DL = W= Areaiag = SPanc = p=gh(GCrn)YEYcYp p = 79.2 p.s.f. (eq 29.4-6) controlling load combination (eq. 16-15 for ASD) 2.8 p.s.f. 79.2 p.s.f. 11.3 sq. ft. 4.0 ft. Puplift = Areaiag (0.6DL - 0.6W) = Material = Diaiag = Penlag = Wiag = CD = Ct = N °screws = dead load of panel (inlcuding rack system) wind load normal to face of panel area tributary to each anchor spacing of anchors 518.4 Ibs total uplift on anchor DFL lumber anchor material 5/16 in. diameter of screw 3 in. min. penetration to existing framing 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A 1.6 load duration factor for wind per NDS Table 2.3.2 0.8 temperature factor per NDS Table 2.3.3 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 1021.44 Ibs total allowable withrawal on anchor Puplift Pallow = 0.51 < 1.00 Anchor is OK! Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 3.IN. MIN. PENETRATION 6 of 7 2/6/2023 9:40 AM ©McPherson Engineering _NEE-L McPherson Engineering By: FA. Date: 2/6/23 Summary Gravity Loads: DEMAND DECREASED BY 5.2% = OK! Lateral Loads: DEMAND INCREASED BY 2.73% < 10% = OK! Anchorage: DEMAND OF 518.4LB. < CAPACITY OF 1021.4LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 3.IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! 7 of 7 2/6/2023 9:40 AM ©McPherson Engineering