BCOM2021-0041DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Permit Number
Property Address
APN:
Legal Description
Property Zoning:
Valuation:
Building Commercial
BCOM2021-0041
BUILDING PERMIT
eca Qa�&a
CALIFORNIA
46660 WASHINGTON ST STE 10
643020063
$325,000.00
Owner:
Applicant
Contractor:
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 07/14/2021
ISSUED DATE: 10/04/2021
WASHINGTON 111 LTD
30240 Rancho Viejo Rd, Suite B, San Juan
Capistrano, CA 92673
Greg Landry
1202 Richardson Dr., Suite 106, Richardson, TX
75080
SHIELDS CONTRACTING INC
35676 KEANE CT, WILDOMAR, CA 92595
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 11/18/24 10:36 am Page 1 of 5
1-311111]1Z"a4 NV,IkI
Permit Type: Building Commercial
Permit Number: BCOM2021-0041
Property Address: 46660 WASHINGTON ST STE 10
application does not relieve that person of the n
construction lender preliminary notice from that duty.
Printed: 11/18/24 10:36 am Page 2 of 5
1-3111101Z"a4NIT, lkI
Permit Type: Building Commercial
Permit Number: BCOM2021-0041
Property Address: 46660 WASHINGTON ST STE 10
NOTHING BUNDT CAKES / 1,928SF BAKERY SHOP TI/VB/B-OCC/15-OL *** 1,928SF BARKERY SHOP TENANT
IMPROVEMENT/VB/B-OCC/15-OL/SPRINKLED [NOTHING BUNDT CAKES] THIS PERMIT DOES NOT INCLUDE ADDITIONAL SQUARE
FOOTAGE, EXTERIOR ALTERATIONS OR SIGNAGE. NO TUMF IMPACT BASED ON SHOPPING CENTER USE. 2019 CALIFORNIA
BUILDING CODES.
ninstruction DPt;.
Commercial Work Type Remodel
Building/Unit
B: Office, Professional
Gross Square Footage 1928
Occupancy
Classification(s)
Conditioned Square 1928
Fire Sprinkler Square
1928
Number of Floors 1
Footage
Footage
Occupant Load 15
Construction Type
V-B
Code Edition 2019
Remodel Area Square 1928
New Electrical Square
1928
Number of 3
Footage
Footage
Condenser(s)
Number of Evaporative 3
Number of Ventilation
1
Number of Exhaust 1
Cooler(s)
Fan(s)
Hood(s)
Number of Plumbing 9
Number of Water
1
Water System Install Yes
Fixtures/Traps
Heater(s)
or Alteration?
Number of Gas 3
Grease Interceptor or
Yes
Transportation Uniform No
Outlet(s)
Sand/Oil Separator?
Mitigation Fee
Applicable
City Development No
Art in Public Places
No
Impact Fee Applicable
Fund Exempt
Type Group Sq Ft Value
Printed: 11/18/24 10:36 am Page 3 of 5
1-311111]1Z"a4 N IT, IkI
Permit Type: Building Commercial
Permit Number: BCOM2021-0041
Property Address: 46660 WASHINGTON ST STE 10
Invoice No.
Fee
Fee Amount
Amount Paid
PERM IT-BCOM2021-00,
BSAS SB1473 FEE
$13.00
$13.00
1
REMODEL, FIRST 100SF PC
$149.73
$149.73
WATER HEATER/VENT PC
$8.05
$8.05
WATER SYSTEM INST/ALT/REP
$13.42
$13.42
NON-RESIDENTIAL, FIRST 2,000SF
$120.75
$120.75
FIXTURE/TRAP PC
$120.78
$120.78
REMODEL, EA ADDITIONAL 500SF
$96.60
$96.60
VENT FAN PC
$5.37
$5.37
FIXTURE/TRAP
$120.78
$120.78
GREASE INTERCEPTOR
$40.25
$40.25
RECORDS MANAGEMENT FEE - MAJOR
$21.00
$21.00
VENT FAN
$13.42
$13.42
EXHAUST HOOD
$13.42
$13.42
CONDENSER/COMPRESSOR
$120.75
$120.75
FIRE COMMERCIAL TI
$161.00
$161.00
EVAPORATIVE COOLER
$40.26
$40.26
CONDENSER/COMPRESSOR PC
$80.49
$80.49
REMODEL, FIRST 100SF
$54.74
$54.74
GAS SYSTEM, 1-4 OUTLETS
$13.42
$13.42
ALTERATIONS/ADDITIONS - NON-RESIDENTIAL
$161.00
$161.00
EVAPORATIVE COOLER PC
$40.26
$40.26
GREASE INTERCEPTOR PC
$13.42
$13.42
NON-RESIDENTIAL, FIRST 2,000SF PC
$15.52
$15.52
PLAN CHECK DEPOSIT - COMMERCIAL
$1,500.00
$1,500.00
GAS SYSTEM, 1-4 OUTLETS PC
$26.83
$26.83
REMODEL, EA ADDITIONAL 500SF PC
$77.28
$77.28
EXHAUST HOOD PC
$5.37
$5.37
NON-RESIDENTIAL, FIRST 2,000SF PC
$77.86
$77.86
SMI - COMMERCIAL
$91.00
$91.00
TECHNOLOGY ENHANCEMENT FEE
$5.00
$5.00
FIRE COMMERCIAL TI PC
$242.00
$242.00
WATER HEATER/VENT
$13.42
$13.42
WATER SYSTEM INST/ALT/REP PC
$13.42
$13.42
ART IN PUBLIC PLACES - COMMERCIAL REMOD
$1,125.00
$1,125.00
Total for Invoice
PERMIT-BCOM2021-0041
$4,614.61
$4,614.61
Grand Total for Permit
$4,614.61
$4,614.61
Workflow Step / Action Name
Action Type
Start Date
End Date
Inspections v.1
07/14/2021 0:00
FINAL"" v.3
Inspection
FINAL"" v.2
Inspection
FINAL INSPECTION
v.2
Inspection
FINAL"" v.1
Inspection
Printed: 11/18/24 10:36 am Page 4 of 5
1:31111111111]1Z"a4NIT, lkI
Permit Type: Building Commercial
Permit Number: BCOM2021-0041
Property Address: 46660 WASHINGTON ST STE 10
T-BAR/OVERHEAD v.3
Inspection
T-BAR/OVERHEAD v.2
Inspection
T-BAR/OVERHEAD v.1
Inspection
FINAL INSPECTION v.1
Inspection
OVERHEAD ROUGH PIPING v.2
Inspection
OVERHEAD ROUGH PIPING v.1
Inspection
DRYWALL NAIL v.2
Inspection
DRYWALL NAIL v.3
Inspection
FRAMING v.3
Inspection
DRYWALL NAIL v.1
Inspection
GAS LINE/TEST v.1
Inspection
ROUGH PLBG v.2
Inspection
ROUGH MECH v.2
Inspection
FRAMING v.2
Inspection
ROUGH ELEC v.2
Inspection
ROUGH MECH v.1
Inspection
ROUGH PLBG v.1
Inspection
ROUGH ELEC v.1
Inspection
FRAMING v.1
Inspection
UNDERGROUND PLBG v.1
Inspection
UNDERGROUND ELEC v.1
Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
iurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the buildinq official.
Printed: 11/18/24 10:36 am Page 5 of 5
To whom it may concern
The entirety of the menu and subsequent baking of product in the oven does not produce grease laden
vapors. The premanufactured cake mix is mixed with water, poured into bundt cake molds, placed into
rolling racks, and baked into cakes of various flavors and sizes in the oven. No grease laden vapors are
generated in this process that would require the use of a type 1 hood and the ancillary components that go
along with type 1 hood construction. The hood we use is dual rated for type 1 or 2 use but the strict NbC
process and product does not, and will not, make use of the oven in a manner necessitating a type 1
rating.
Thank you,
Chris Bremer
Chief Development Officer
;aunty 4oF Ftlwq5rsid4--
3OF F-h[VlRiONMEM-rfikL HEALTH
dr
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL — LA QUINTA c,,LIFoRMA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
July 22, 2021
Cortland Morgan Architect
711 N. Fielder Rd
Arlington, TX 76012
Re: Tenant Improvement Construction - Fire Plan Review — NOTHING BUNDT CAKE
BCOM2021-0041 / 46660 WASHINGTON ST #10, LA QUINTA, CA 92253
The building plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Fire Department approval is based upon the 2019 CBC requirements for B occupancies. It is prohibited to
use, process or store any materials in the occupancy that would classify it as a Group H occupancy, without
further review and approval.
DEFERRED SUBMITTALS REQUIRED
1) FIRE SPRINKLER SYSTEM - Tenant Improvement plans must be submitted and reference the
installing contractor performing the work. Permit fees will be required.
2) FIRE ALARM/MONITORING SYSTEM - Tenanat Improvement plans must be submitted per NFPA
72 as required by the California Building Code, California Fire Code and designed in accordance with
adopted standards. A C-10 licensed contractor must submit plans to the Office of the Fire Marshal for
review and approval prior to installation. Permit fees will be required.
PRIOR TO FINAL
1) Approved building address shall be placed in such a position as to be plainly visible and legible from the
street and rear access if applicable. Minimum 6" tall suite addressing shall be provided to both the front
and rear entrances. All addressing must be legible and of a contrasting color with the background to be
visible from the street at all hours.
2) Provide keys to the tenant space (all tenants), utility rooms and elevator services for inclusion in the
main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the
correlating tenant space.
3) Install portable fire extinguishers per Title 19, but not less than 2A1013C in rating. Contact a certified
extinguisher company for proper placement and spacing of equipment.
4) Applicable room door(s) shall be posted "ELECTRICAL", "FACP", "FIRE RISER" and "ROOF
ACCESS" on the outside of the door so it is visible and in a contrasting color.
5) A durable sign stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS
OCCUPIED" shall be placed on or adjacent to the front exit doors. The sign shall be in letters not less
than one inch high on a contrasting background (A <300, B, F, M and S).
6) Illuminated Exit Signage and Egress Illumination placement and functional test will be witnessed by
OFM Fire Inspector at time of final inspection.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131
Kev #1R95
COACHELLA VALLEY WATER DISTRICT
TIN
75-515 Hovlcy Lane East
Palm Desert, California 92211
�j�.�.Rt (760) 398-2651
APPLICATION FOR WASTEWATER SOURCE CONTROL PLAN APPROVAL
APPI 1CANT Submit this form with a copy of a SCAT FD plot plan (1"-20' to F' - 40' SCALF) drawn to District specifications A nonrefundable filine fee is
required when the application is submitted Check must be made payable to the Coachella Valley Water District Approval of this application shall remain valid for
a period not to exceed one (1) year from dale ol'payment \Oft•.: ALL CSFRS DISCHARGING F %F. OII., ANDlOR GREASE. LOCATED IN A ML
SUI I E BUILDING M ILL REQL IRE A SF.PAFL%I'E LAI ERAL OFF 1 HF; MAIN SEWER LINE FOR GREASE INTERCEPTOR CONNECTION.
C%'WD Source Control will inspect the exposed grease plumbing and the installed interceptor. Please call (760) 398-2661 X3710 48 hours in advance
to schedule ins ection s .
Agent, Contractor. Contact Person
Address City State Zip
Telephone
Owner
Address City State Zip -
(,vaLAC =� LA Ta CA. `/'ZL
Telephone
"i eC5 U
Job Site Address City 5 Zj Zip
/
Business Type
ZA
Doing Business As
I !cl fir t.Lv� �i<�S
NOTE: NO PLANS 1V1LL E APPROVED UN FIL THIS APPLICATION IS COMPLETE AND PLAN CHECK FEES ARE PAID.
I'ypc of Construction: Netc ❑ Remodel hours ofUperation:
Cooling lower(s) ❑
For Vehicle Service: For
Food Service:
❑ Wand Bays ❑ Trench Drains ( ll)
❑ Roll over ❑ Service bay(s)
❑ Water Sollener ❑ Garbage Grinder(s) ❑ Digester(s)
Multiservice (reusable) % Single Service (disposable)]%
❑ Tunnel(s) ❑ Parts Washer
Seating Capacity: Internal External
❑ Spill Containment (Solvent ❑ Aqueous ❑)
Seating with Miste or Heat rs
❑ H draulic Lift(s) ❑Work Sink s)
Bar SeatingBar S n with Food Service
Obi NLRIRLPI,L.�LN IAI 1 V L DUILARA I ION: I certity that I have read the entire application and state that all mtormation is correct. I
understand that the fee amount is b 'ed on in) declaration of information on this form and that incorrect information is grounds f'or rejection of the
District
submitted plans. 1 also understand 1h t plans may be discarded if not picked up within sixty (60) days of approval or return and that no
inspection ofll b conducted until all requested info iati n has been received and plans have been approved.
Signature% �� Date L `fzi
FOR DISTRICT USE ONLY
No. of Systems
Type of System(s)
Pretreatment Equipment:
❑ Grease Interceptor gGrease Interceptor Waived
O
❑ New ❑ Existing
❑
❑ Sand/nil
Connect to Sewer Addition
❑ Lint Trap ❑ Point of Connection Sample Station
❑ Replacement
❑ Clarifier ❑ Digester(s)
Size: pals
REMARKS:
1 . No grease interceptor will be required at this establishment at this moments if future
inspections reveal high grease production,
2). CVWD encourages our customers to establish and follow 000d Best Management Prainfices.
3). Only water softeners stems with exchangeable bottles are allowed. Thankyou!
This application is:
PZ ! (,Y LID 7 7 0J V
EX Conditionally Approved* ❑ Approved
C3
*See Remarks
Fee S Check No. V i J
D � AA
Sigiiatttic I`Ja✓ 0. Pit. `
_��
Initial]
Date d )) 7 b \
r "ate 8-5-2021
County of Riverside
DEPARTMENT OF ENVIRONMENTAL HEALTH
P.O. BOX 7909 + RIVERSIDE, CA 92513-7909
KEITH JONES, DIRECTOR
FOOD ESTABLISHMENT PLAN APPROVAL NOTICE
Plan Check # 52346
Project Nothing 6undtCakes
Name
Plans Submitted by Mike Clark
Date 9-28-2021
Address 46-660 Washington Street Suite 110, La Quinta
Owner Jefferey Tropple Address 50075 Malaga Ct, La Quinta CA
Phone 214-631-
6491x204
Phone 760-805-5684
The plans are now approved subject to the conditions listed below and the attached compliance sheet.
1. Provide air curtain on delivery door
2. The outside dumpster bin to have smooth interior walls and floor with epoxy seal.
3. Must post a sign in Lobby "no customer restrooms available".
Nate: grease interceptor waiver letter from the sewer agency received.
Note: Owner Jeffery Tropple verified that they do not use fresh produce for bakery products
therefore no r)rep sink is reauired at this time.
CONSTRUCTION INSPECTIONS: Contact the Plan Checker for a Preliminary Inspection when construction is
approximately 80% complete, with plumbing, rough ventilation, and rough equipment installed. Request for
inspection should be made at least five (5) working days in advance.
**ALL ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL REPAIRS AND INSTALLATIONS SHALL BE
DONE UNDER PERMIT FROM THE APPROPRIATE BUILDING & SAFETY DEPARTMENT (CITY OR COUNTY)"
A FINAL INSPECTION MUST be made upon completion of ALL work including finished details. APPROVAL to
operate shall not be granted, or remodeled areas approved to operate, until the facility has passed the FINAL
INSPECTION, and "APPLICATION TO OPERATE" has been completed and PERMIT FEES have been paid.
Request for inspection should be made at least five (5) working days in advance.
PLANS CHECKED BY Tracey Ford Phone 760-863-8287
acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate them
during construction:
Signature Date
G 4
Company Name, k6Ls6 �r
Corona Hemet Indio Murrieta Palm Springs Riverside -west
Riverside -East
2275 S. Main St 9204 800 S. S anderson #200 47-950 Arabia St "A' 38740 Sky Canyon Dr. 344 S. Paseo Dorotea 4065 County Circle
3880 Lemon St.
Corona, Ca 92882 Hemet, Ca 92545 Indio, Ca 92201 Murrieta, Ca 92563 Palm Springs, Ca Riverside, Ca 92503
Riverside, Ca 92501
(951)273-9140 (951)766-2824 (760)863-8287 (951)461-0284 92264 (951)358-5172
(951) 955-8982
760-320-1048
Office Locations a Blythe a Corona • Hemet a Indio • Murrieta a Palm Springs * Riverside
Phone (888)722-4234
www.rivcoeh.org