Loading...
BCOM2018-0041 - Energy DocsTABLE OF CONTENTS Cover Page Table of Contents Form PRF-01-E Certificate of Compliance Form ENV-MM Envelope Mandatory Measures 1 2 3 22 CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: DATE: 02/06/2019 BCOM2018-0041 SHELL BUILDING IMPROVEMENTS TO CREATE TWO TENANT LEASE SPACES WITH TWO SEPARATE ENTRANCE FACADES AND ADDITIONAL REAR EXIT [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BUILDING OCCUPANCY OR REVIEW OF SPECULATIVE BUILDING USES. PATH OF TRAVEL UPGRADES REQUIRED TO BE COMPLETED PRIOR TO BUILDING OCCUPANCY. 2016 CALIFORNIA BUILDING CODES. Project Name:Nonresidential Building NRCC-PRF-01-E Page 1 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 A. PROJECT GENERAL INFORMATION 1.Project Location (city)La Quinta 8.Standards Version Compliance2016 2.CA Zip Code 92253 9.Compliance Software (version)EnergyPro 7.2 3.Climate Zone 15 10.Weather File PALM-SPRINGS-INTL_722868_CZ2010.epw 4.Total Conditioned Floor Area in Scope 11,654 ft2 11.Building Orientation (deg)(W) 270 deg 5.Total Unconditioned Floor Area 0 ft2 12.Permitted Scope of Work NewComplete 6.Total # of Stories (Habitable Above Grade)1 13 Building Type(s)Nonresidential 7.Total # of dwelling units 0 14 Gas Type NaturalGas B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2-yr)§ 140.1 BUILDING COMPLIES 1. Energy Component 2. Standard Design (TDV)3. Proposed Design (TDV)4. Compliance Margin (TDV)5. Percent Better than Standard Space Heating 2.09 1.01 1.08 51.7% Space Cooling 132.29 113.22 19.07 14.4% Indoor Fans 28.26 36.25 -7.99 -28.3% Heat Rejection -------- Pumps & Misc.0.13 --0.13 -- Domestic Hot Water 5.86 3.13 2.73 46.6% Indoor Lighting 101.54 101.54 --0.0% COMPLIANCE TOTAL 270.17 255.15 15.02 5.6% Receptacle 89.23 89.23 0.0 0.0% Process -------- Other Ltg -------- Process Motors -------- TOTAL 359.40 344.38 15.0 4.2% Project Name:Nonresidential Building NRCC-PRF-01-E Page 2 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings) 1st Space Cooling: Check envelope and mechanical Compliance Margin By Energy Component (from Table B column 4) Space Cooling Domestic Hot Water Space Heating Pumps & Misc. Heat Rejection Indoor Lighting Indoor Fans Penalty Energy Credit 2nd Domestic Hot Water: Check mechanical 3rd Space Heating: Check envelope and mechanical 4th Pumps & Misc.: Check mechanical 5th Heat Rejection: Check envelope and mechanical 6th Indoor Lighting: Check lighting 7th Indoor Fans: Check envelope and mechanical D. EXCEPTIONAL CONDITIONS The aged solar reflectance and aged thermal emittance must be listed in the Cool Roof Rating Council database of certified products. For projects where initial reflectance is used, the initial reflectance must be listed, and the aged reflectance is calculated by the software program and used in the compliance model. This project uses the Simplified Geometry Performance Modeling Approach which is not capable of modeling daylighting controls and assumes the prescriptive Secondary Daylit Control requirements are met. PRESCRIPTIVE COMPLIANCE documentation (form NRCC-LTI-02-E) for the requirements of section 140.6(d) Automatic Daylighting Controls in Secondary Daylit Zones is required. This project includes Domestic Hot Water in the analysis. Please verify that Domestic Hot Water is included in the design for the permitted scope of work. E. HERS VERIFICATION This Section Does Not Apply F. ADDITIONAL REMARKS None Provided Project Name:Nonresidential Building NRCC-PRF-01-E Page 3 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY Identify which building components use the performance or prescriptive path for compliance. “NA”= not in project For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans. Building Component Compliance Path Compliance Forms (required for submittal)Location of Mandatory Notes on Plans Envelope Performance NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E) Prescriptive NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E NA Mechanical Performance NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E) Prescriptive NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E NA Domestic Hot Water Performance NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E) Prescriptive NRCC-PLB-01-E NA Lighting (Indoor Conditioned) Performance NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-01-E) Prescriptive NRCC-LTI-01 / 02 / 03 / 04 / 05-E NA Covered Process: Commercial Kitchens Performance S2 (section of the NRCC-PRF-01-E) Prescriptive NRCC-PRC-01/ 03-E NA Covered Process: Computer Rooms Performance S3 (section of the NRCC-PRF-01-E) Prescriptive NRCC-PRC-01/ 04-E NA Covered Process: Laboratory Exhaust Performance S4 (section of the NRCC-PRF-01-E) Prescriptive NRCC-PRC-01/ 09-E NA Project Name:Nonresidential Building NRCC-PRF-01-E Page 4 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY The following building components are only eligible for prescriptive compliance. Indicate which are relevant to the project. The following building components may have mandatory requirements per Part 6. Indicate which are relevant to the project. Yes NA Prescriptive Requirement Compliance Forms Yes NA Mandatory Requirement Compliance Forms Lighting (Indoor Unconditioned) §140.6 NRCC-LTI-01 / 02 / 03 / 04 / 05-E   Commissioning: §120.8 Simple Systems Complex Systems   NRCC-CXR-01 / 02 / 03 / 05-E NRCC-CXR-01 / 02 / 04 / 05-E Lighting (Outdoor) §140.7 NRCC-LTO-01 / 02 / 03-E Electrical: §130.5 NRCC-ELC-01-E Lighting (Sign) §140.8 NRCC-LTS-01-E Solar Ready: §110.10 NRCC-SRA-01 / 02-E Solar Thermal Water Heating: §140.5 NRCC-STH-01-E   Covered Process: §120.6 Parking Garage Commercial Refrigeration Warehouse Refrigeration Compressed Air Process Boilers NRCC-PRC-01-E NRCC-PRC-02-E NRCC-PRC-05-E NRCC-PRC-06/07/08-E NRCC-PRC-10-E NRCC-PRC-11-E Project Name:Nonresidential Building NRCC-PRF-01-E Page 5 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV)– Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal)Pass Fail Envelope  NRCI-ENV-01-E - For all buildings   NRCA-ENV-02-F- NFRC label verification for fenestration Mechanical  NRCI-MCH-01-E - For all buildings with Mechanical Systems   NRCA-MCH-02-A- Outdoor Air   NRCA-MCH-03-A – Constant Volume Single Zone HVAC   NRCA-MCH-04-H- Air Distribution Duct Leakage   NRCA-MCH-05-A- Air Economizer Controls   NRCA-MCH-06-A- Demand Control Ventilation   NRCA-MCH-07-A – Supply Fan Variable Flow Controls   NRCA-MCH-08-A- Valve Leakage Test   NRCA-MCH-09-A – Supply Water Temp Reset Controls   NRCA-MCH-10-A- Hydronic System Variable Flow Controls   NRCA-MCH-11-A – Auto Demand Shed Controls   NRCA-MCH-12-A- Packaged Direct Expansion Units   NRCA-MCH-13-A- Air Handling Units and Zone Terminal Units   NRCA-MCH-14-A- Distributed Energy Storage   NRCA-MCH-15-A – Thermal Energy Storage   NRCA-MCH-16-A- Supply Air Temp Reset Controls   NRCA-MCH-17-A – Condensate Water Temp Reset Controls   NRCA-MCH-18-A- Energy Management Controls Systems   NRCV-MCH-04-H- Duct Leakage Test Project Name:Nonresidential Building NRCC-PRF-01-E Page 6 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV)– Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal)Pass Fail Plumbing  NRCI-PLB-01-E - For all buildings with Plumbing Systems   NRCI-PLB-02-E - required on central systems in high‐rise residential, hotel/motel application.   NRCI-PLB-03-E - Single dwelling unit systems in high‐rise residential, hotel/motel application.   NRCI-PLB-21-E - HERS verified central systems in high‐rise residential, hotel/motel application.   NRCI-PLB-22-E - HERS verified single dwelling unit systems in high‐rise residential, hotel/motel application.   NRCV-PLB-21-H- HERS verified central systems in high‐rise residential, hotel/motel application.   NRCV-PLB-22-H - HERS verified single dwelling unit systems in high‐rise residential, hotel/motel application.   NRCI-STH-01-E - Any solar water heating Indoor Lighting  NRCI-LTI-01-E - For all buildings   NRCI-LTI-02-E - Lighting control system, or for an Energy Management Control System (EMCS)   NRCI-LTI-03-E - Line-voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line-voltage track lighting   NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a convention center, a conference room, or a theater   NRCI-LTI-05-E - Lighting Control Credit Power Adjustment Factor (PAF)   NRCI-LTI-06-E - Additional wattage installed in a video conferencing studio   NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls.   NRCA-LTI-03-A - Automatic daylighting controls   NRCA-LTI-04-A - Demand responsive lighting controls Outdoor Lighting  NRCI-LTO-01-E – Outdoor Lighting   NRCI-LTO-02-E- EMCS Lighting Control System   NRCA-LTO-02-A - Outdoor Lighting Control Sign Lighting  NRCI-LTS-01-E – Sign Lighting Electrical  NRCI-ELC-01-E - Electrical Power Distribution Photovoltaic  NRCI-SPV-01-E Photovoltaic Systems Project Name:Nonresidential Building NRCC-PRF-01-E Page 7 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV)– Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal)Pass Fail Covered Process  NRCI-PRC-01-E Covered Processes   NRCA-PRC-01-F- Compressed Air Systems   NRCA-PRC-02-F- Kitchen Exhaust   NRCA-PRC-03-F- Garage Exhaust   NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls   NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls   NRCA-PRC-06-F- Refrigerated Warehouse- Air Cooled Condenser Controls   NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor   NRCA-PRC-08-F- Electrical Resistance Underslab Heating System I. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information) 1.Total Conditioned Floor Area 11,654 ft2 5.Number of Floors Above Grade 1 Confirmed 2.Total Unconditioned Floor Area 0 ft2 6.Number of Floors Below Grade 0 PassFail3.Addition Conditioned Floor Area 0 ft2 4.Addition Unconditioned Floor Area 0 ft2 7. Opaque Surfaces & Orientation 8. Total Gross Surface Area 9. Total Fenestration Area 10. Window to Wall Ratio North Wall 980 ft2 0 ft2 00.0% East Wall 1,270 ft2 0 ft2 00.0% South Wall 980 ft2 0 ft2 00.0% West Wall 1,270 ft2 400 ft2 31.5% Total 4,500 ft2 400 ft2 08.9% Roof 11,654 ft2 0 ft2 00.0% Project Name:Nonresidential Building NRCC-PRF-01-E Page 8 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 J. FENESTRATION ASSEMBLY SUMMARY § 110.6 Confirmed 1.2.3.4.5.6.7.8.9.PassFailFenestration Assembly Name / Tag or I.D. Fenestration Type / Product Type / Frame Type Certification Method1 Assembly Method Area ft2 Overall U-factor Overall SHGC Overall VT Status2Double Non Metal Clear VerticalFenestration FixedWindow N/A NFRC Rated SiteBuilt 400 0.36 0.25 0.50 N 1 Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 110.6-A and Table 110.6-B. Center of Glass (COG) values are for the glass-only, determined by the manufacturer, and are shown for ease of verification. Site-built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis. 2 Status: N - New, A – Altered, E – Existing Taking compliance credit for fenestration shading devices?(if "Yes", see NRCC-PRF-ENV-DETAILS for more information)No K. OPAQUE SURFACE ASSEMBLY SUMMARY § 120.7/ § 140.3 Confirmed 1.2.3.4.5.6.7.8.PassFailSurface Name Surface Type Area (ft2)Framing Type Cavity R-Value Continuous R-Value U-Factor / F-Factor / C-Factor Status1R19 Wall6 ExteriorWall 4500 Wood 19 NA U-Factor: 0.072 N R-30 Roof No Attic13 Roof 11654 Wood 30 NA U-Factor: 0.034 N Slab On Grade15 UndergroundFloor 11654 NA 0 NA F-Factor: 0.730 N R19 Wall61 InteriorWall 980 Wood 19 NA U-Factor: 0.069 N 1 Status: N - New, A – Altered, E – Existing L. ROOFING PRODUCT SUMMARY § 140.3 Confirmed 1.2.3.4.5.6.7.PassFailProduct Type Product Density (lb/ft2) Aged Solar Reflectance Thermal Emittance SRI Cool Roof Credit Roofing Product Description R-30 Roof No Attic13 5.813 0.63 0.85 Not Provided Yes CRRC Prod. ID: R-30 Roof No Attic Project Name:Nonresidential Building NRCC-PRF-01-E Page 9 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 M. HVAC SYSTEM SUMMARY (see NRCC-PRF-MCH-DETAILS for more information)§ 110.1 / § 110.2 Dry System Equipment 1 (Fan & Economizer info included below in Table N)Confirmed 1.2.3.4.5.6.7.8.9.10.11.PassFailEquip Name Equip Type System Type (Simple 2 or Complex 3) Qty Total Heating Output (kBtu/h) Supp Heat Source (Y/N) Supp Heat Output (kBtuh) Total Cooling Output (kBtu/h) Efficiency Acceptance Testing Required? (Y/N) 4 Status5Cooling Heating RTU - 1 2 SZAC (Packaged3Phase)Simple 2 114 No 0 115 EER-12.2 AFUE-80.0 Yes N RTU - 3 4 SZAC (Packaged3Phase)Simple 2 114 No 0 115 EER-12.2 AFUE-80.0 Yes N 1 Dry System Equipment includes furnaces, air handling units, heat pumps, etc. 2 Simple Systems must complete NRCC-CXR-03-E commissioning design review form 3 Complex Systems must complete NRCC-CXR-04-E commissioning design review form 4 A summary of which acceptance tests are applicable is provided in NRCC-PRF-MCH-DETAILS 5 Status: N - New, A – Altered, E – Existing Wet System Equipment 1 Pumps Confirmed 12.13.14.15.16.17.18.19.20.21.22.23.24.PassFailEquip Name Equip Type Qty Vol (gal)Rated Capacity (kBtu/h)Efficiency Standby Loss Tank Ext. R Value Qty GPM HP VSD (Y/N)Status2Standard Gas Tankless2 Instantaneous 2 1.00 199 EF: 0.94 SBLF: NA NA NA No N 1 Wet System Equipment includes boilers, chillers, cooling towers, water heaters, etc. 2 Status: N - New, A – Altered, E – Existing Discrepancy between modeled and designed equipment sizing?(if "Yes", see Table F. "Additional Remarks" for an explanation)No Project Name:Nonresidential Building NRCC-PRF-01-E Page 10 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 N. ECONOMIZER & FAN SYSTEMS SUMMARY1 § 140.4 Confirmed 1.2.3.4.5.PassFailEquip Name Outside Air Supply Fan Return Fan Economizer Type (if present) CFM CFM HP BHP TSP (inch WC) Control CFM HP BHP TSP (inch WC) Control RTU - 1 2 584 4000 1.000 1.000 0.95 ConstantVolume NA NA NA NA NA NoEconomizer RTU - 3 4 581 4000 1.000 1.000 0.95 ConstantVolume NA NA NA NA NA NoEconomizer 1 Mechanical ventilation calculations and exhaust fans are included in the NRCC-PRF-MCH-DETAILS section O. EQUIPMENT CONTROLS § 120.2 Confirmed 1.2.3.PassFailEquip Name Equip Type Controls RTU - 1 2 SZAC No DCV Controls No Economizer No Supply Air Temp. Control No Optimum Start No Evaporative Cooler No Heat Recovery RTU - 3 4 SZAC No DCV Controls No Economizer No Supply Air Temp. Control No Optimum Start No Evaporative Cooler No Heat Recovery DHW1 - SHW Service Hot Water, Primary Only Fixed Temperature Control, No DDC No Heat Recovery Project Name:Nonresidential Building NRCC-PRF-01-E Page 11 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 P. SYSTEM DISTRIBUTION SUMMARY § 120.4/ § 140.4(I) Dry System Distribution Confirmed 1.2.3.4.5.6.PassFailEquip Name Equip Type Duct Leakage and Sealing Required per 140.4(l) Duct Leakage will be verified per NA1 and NA2 Ducts Status1Insulation R-Value Location RTU - 1 2 SZAC No No 4.2 Conditioned N RTU - 3 4 SZAC No No 4.2 Conditioned N 1 Status: N - New, E – Existing Does the Project Include Zonal Systems? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information)No Does the Project Include a Solar Hot Water System? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information)No Multifamily or Hotel/ Motel Occupancy? (if "Yes", see NRCC-PRF-MCH-DETAILS for DHW system information)No Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info)3 § 140.6 Confirmed 1.2.3.4.5.PassFailOccupancy Type 1 Conditioned Floor Area 2 (ft2) Installed Lighting Power (Watts) Lighting Control Credits (Watts)Additional (Custom) Allowance Area Category Footnotes (Watts)Tailored Method (Watts) Retail Merchandise Sales, Wholesale Showroom 11,654 13,985 0 0 0 Building Totals:11,654 13,985 0 0 0 1 See Table 140.6-C 2 See NRCC-LTI-01-E for unconditioned spaces 3Lighting information for existing spaces modeled is not included in the table R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)1 § 130.0 This Section Does Not Apply 1If lighting power densities were used in the compliance model Building Departments will need to check prescriptive forms for Luminaire Schedule details. S1. COVERED PROCESS SUMMARY – ENCLOSED PARKING GARAGES § 140.9 This Section Does Not Apply Project Name:Nonresidential Building NRCC-PRF-01-E Page 12 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 S2. COVERED PROCESS SUMMARY – COMMERCIAL KITCHENS § 140.9 This Section Does Not Apply S3. COVERED PROCESS SUMMARY – COMPUTER ROOMS § 140.9 This Section Does Not Apply S4. COVERED PROCESS SUMMARY – LABORATORY EXHAUSTS § 140.9 This Section Does Not Apply T. UNMET LOAD HOURS This Section Does Not Apply U. ENERGY USE SUMMARY Energy Component Standard Design Site (MWh) Proposed Design Site (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Space Heating 0.0 ----14.1 7.0 7.1 Space Cooling 47.6 40.4 7.2 ------ Indoor Fans 11.3 18.2 -6.9 ------ Heat Rejection ------------ Pumps & Misc.0.1 ---------- Domestic Hot Water ------47.3 25.1 22.2 Indoor Lighting 48.4 48.4 0.0 ------ COMPLIANCE TOTAL 107.4 107.0 0.4 61.4 32.1 29.3 Receptacle 42.4 42.4 0.0 ------ Process ------------ Other Ltg ------------ Process Motors ------------ TOTAL 149.8 149.4 0.4 61.4 32.1 29.3 E12899 M023887______________________ 10/28/2018Architect of RecordC-27769700 S. Flower Street, 22nd FloorLos Angeles, CA 90017(213) 800-9400 Project Name:Nonresidential Building NRCC-PRF-01-E Page 14 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 NRCC-PRF-ENV-DETAILS -SECTION START- A. OPAQUE SURFACE ASSEMBLY DETAILS Confirmed 1.2.3.4.PassFailSurface Name Surface Type Description of Assembly Layers Notes R19 Wall6 ExteriorWall Stucco - 7/8 in. Vapor permeable felt - 1/8 in. Wood framed wall, 16in. OC, 5.5in., R-19 Gypsum Board - 1/2 in. R-30 Roof No Attic13 Roof Asphalt shingles - 1/4 in. Vapor permeable felt - 1/8 in. Plywood - 1/2 in. Air - Cavity - Wall Roof Ceiling - 4 in. or more Wood framed roof, 16in. OC, 11.25in., R-30 Gypsum Board - 1/2 in. Slab On Grade15 UndergroundFloor Slab Type = UnheatedSlabOnGrade Insulation Orientation = None Insulation R-Value = R0 R19 Wall61 InteriorWall Stucco - 7/8 in. Vapor permeable felt - 1/8 in. Wood framed wall, 16in. OC, 5.5in., R-19 Gypsum Board - 1/2 in. B. OVERHANG DETAILS (Adapted from NRCC-ENV-02-E) This Section Does Not Apply C. OPAQUE DOOR SUMMARY Confirmed 1.2.3.4.5.6.7. Pass FailOpaque Door Assembly Name / Tag or I.D.Door Type Certification Method Operation Area Overall U-factor Status1 Wood Door11 WoodGreaterThanOrEqualTo1.75inThickDoor DefaultPerformance Swinging 105 0.500 N 1 Status: N - New, A – Altered, E – Existing Project Name:Nonresidential Building NRCC-PRF-01-E Page 15 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 NRCC-PRF-MCH-DETAILS -SECTION START- A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2016-NRCC-MCH-03-E)Confirmed 1. DESIGN AIR FLOWS 2. VENTILATION (§ 120.1)PassFailCONDITIONED ZONE NAME HEATING/COOLING SYSTEMIDDESIGN PRIMARY AIR FLOW(CFM)DESIGN PRIMARY MINIMUMAIR FLOW (CFM)MINIMUM PRIMARY AIRFLOW FRACTIONMAXIMUM HEATING AIRFLOW (CFM)MAXIMUM HEATING AIRFLOW FRACTIONDDC CONTROL (Y/N)VENT SYSTEM IDCONDITIONED AREA (ft2)MIN. VENT PER AREA(CFM/ft2)DESIGN NUM. OF PEOPLEMIN. VENT PER PERSON(CFM/person)REQ'D VENT AIR FLOW (CFM)DESIGN VENT AIR FLOW(CFM)TRANSFER AIRFLOW (CFM)DCV (Y/N)Operable Window Interlock §140.4(n) (Y/N) 1-Suite A RTU - 1 2 8,000 NA 0.00 NA NA N RTU - 1 2 5,844 NA 48.71 24.00 1,169 1,169 NA N NA 2-Suite B RTU - 3 4 8,000 NA 0.00 NA NA N RTU - 3 4 5,810 NA 48.43 24.00 1,162 1,162 NA N NA TOTAL 11,654 97.14 2,331 2,331 NA B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY § 140.4 1.2.3.4.5.6.7.8.Confirmed System ID System Type Qty Rated Capacity (kBtuh) Economizer Zone Name Airflow (cfm)Fan PassFailHeating Cooling Design Min.Min. Ratio BHP Cycles ECM Motor 1-Suite A-Trm Uncontrolled 2 NA NA NA 1-Suite A 8000 NA 0.00 NA NA 2-Suite B-Trm Uncontrolled 2 NA NA NA 2-Suite B 8000 NA 0.00 NA NA C. EXHAUST FAN SUMMARY This Section Does Not Apply Project Name:Nonresidential Building NRCC-PRF-01-E Page 16 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 D. DHW EQUIPMENT SUMMARY –(Adapted from NRCC-PLB-01)§ 110.3 Confirmed 1.2.3.4.5.6.7.8.9.10.11.PassFailDHW Name Heater Element Type Tank Type Qty Tank Vol (gal) Rated Input (kBtu/h)Efficiency Tank Insulation R-value (Int/Ext) Standby Loss Fraction Heat Pump Type Tank Location or Ambient Condition Standard Gas Tankless2 Gas Instantaneous 2 1.00 199 EF: 0.94 NA SBLF: NA NA NA E. MULTI-FAMILY CENTRAL DHW SYSTEM DETAILS This Section Does Not Apply F. SOLAR HOT WATER HEATING SUMMARY (Adapted from NRCC-STH-01) This Section Does Not Apply G. MECHANICAL HVAC ACCEPTANCE TESTS & FORMS (Adapted from 2016-NRCC-MCH-01-E)§ RA4 Declaration of Required Acceptance Certificates (NRCA)– Acceptance Certificates that may be submitted. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description MCH-02AMCH-03AMCH-04AMCH-05AMCH-06AMCH-07AMCH-08AMCH-09AMCH-10AMCH-11AMCH-12AMCH-13AMCH-14AMCH-15AMCH-16AMCH-17AMCH-18AConfirmed Equipment Requiring Testing or Verification # of units Outdoor AirSingle Zone UnitaryAir Dist. DuctsEconomizer ControlsDCVSupply Fan VAVValve leakageSupply Water Temp.ResetHyd. Variable FlowControlAuto Demand ShedControlFDD for DX UnitsAuto FDD for Air &ZoneDist. Energy StorageDX ACTES SystemsSupply Air Temp. ResetCondenser WaterReset ControlsECMSPassFailDHW1 - SHW 1 ---------------------------------- RTU - 1 2 2 X X ------------------------------ RTU - 3 4 2 X X ------------------------------ Project Name:Nonresidential Building NRCC-PRF-01-E Page 17 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 H. EVAPORATIVE COOLER SUMMARY This Section Does Not Apply NRCC-PRF-LTI-DETAILS -SECTION START- A. INDOOR CONDITIONED LIGHTING CONTROL CREDITS (Adapted from NRCC-LTI-02-E)§ 140.6 This Section Does Not Apply B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E)§ 130.1 This Section Does Not Apply §130.1(a) = Manual area controls; §130.0(b) = Multi Level; §130.1(c) = Auto Shut-Off; §130.1(d) = Mandatory Daylight; §130.1(e) = Demand Responsive C. TAILORED METHOD CONDITIONED LIGHTING POWER ALLOWANCE SUMMARY AND CHECKLIST (Adapted from NRCC-LTI-04-E)§ 140.6 General lighting power (see Table D)0 General lighting power from special function areas (see Table E)NA Additional "use it or lose it" (See Table G)0 Total watts 0 D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E)§ 140.6-D This Section Does Not Apply E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E)§ 140.6(c) 3H Room Number Primary Function Area Illuminance Value (LUX) Room Cavity Ratio (Table G)Allowed LPD Floor Area (ft2)Allowed Watts Confirmed Pass Fail NA NA NA NA NA NA NA Note: Tailored Method for Special Function Areas is not currently implemented F. ROOM CAVITY RATIO (Adapted from NRCC-LTI-04-E) Rectangular Spaces Room Number Task/Activity Description Room Length (ft)Room Width (ft)Room Cavity Height (ft)RCR Confirmed Pass Fail NA NA NA NA NA NA Project Name:Nonresidential Building NRCC-PRF-01-E Page 18 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 Non-Rectangular Spaces This Section Does Not Apply Note: All applicable spaces are listed under the Non-Rectangular Spaces table G. ADDITIONAL “USE IT OR LOSE IT” (Adapted from NRCC-LTI-04-E) 1.2.3.4. Allowed Watts Confirmed Wall Display Combined Floor Display and Task Lighting Combined Ornamental and Special Effects Lighting Very Valuable Merchandise PassFail0 0 0 0 0 5. Wall Display This Section Does Not Apply 6. Floor Display and Task Lighting This Section Does Not Apply 7. Combined Ornamental and Special Effects Lighting This Section Does Not Apply 8. Very Valuable Merchandise This Section Does Not Apply H. INDOOR & OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E)§ 130.4 Declaration of Required Acceptance Certificates (NRCA) –Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description Indoor Outdoor Confirmed NRCA-LTI-02-A NRCA-LTI-03-A NRCA-LTI-04-A NRCA-LTO-02-A PassFailEquipment Requiring Testing or Verification # of units Occ Sensors / Auto Time Switch Auto Daylight Demand Responsive Outdoor Controls Occupant Sensors 1 Automatic Time Switch 0 Automatic Daylighting 1 Project Name:Nonresidential Building NRCC-PRF-01-E Page 19 of 19 Project Address:46-630 Washinton Street La Quinta 92253 Calculation Date/Time:10:01, Thu, Oct 18, 2018 Compliance Scope:NewComplete Input File Name:Washington Park (Retail).cibd16x CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-09132018-5583 Report Generated at: 2018-10-18 10:02:00 H. INDOOR & OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E)§ 130.4 Declaration of Required Acceptance Certificates (NRCA) –Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description Indoor Outdoor Confirmed NRCA-LTI-02-A NRCA-LTI-03-A NRCA-LTI-04-A NRCA-LTO-02-A PassFailEquipment Requiring Testing or Verification # of units Occ Sensors / Auto Time Switch Auto Daylight Demand Responsive Outdoor Controls Demand Responsive 1 Outdoor Controls 1 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV-MM Project Name Date DESCRIPTION Building Envelope Measures: §110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §110.8(g): Heated slab floors shall be insulated according to the requirements in Table 110.8-A. §110.7(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. §110.6(a): Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.² of window area, 0.3 cfm/ft.² of door area for residential doors, 0.3 cfm/ft.² of door area for nonresidential single doors (swinging and sliding), and 1.0 cfm/ft.² for nonresidential double doors (swinging). §110.6(a): Fenestration U-factor shall be rated in accordance with NFRC 100, or the applicable default U-factor. §110.6(a) : Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site-built fenestration, or the applicable default SHGC. §110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). §120.7(a): The opaque portions of the roof/ceiling that separates conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U-Factor requirements as follows: Metal Building- The weighted average U-factor of the roof assembly shall not exceed 0.098. Wood Framed and Others- The weighted average U-factor of the roof assembly shall not exceed 0.075. §120.7(b): The opaque portions of walls that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U-factor as follows: Metal Building- The weighted average U-factor of the wall assembly shall not exceed 0.113. Metal Framed- The weighted average U-factor of the wall assembly shall not exceed 0.151. Light Mass Walls- A 6 inch or greater Hollow Core Concrete Masonry Unit shall have a U-factor not to exceed 0.440. Heavy Mass Walls- An 8 inch or greater Hollow Core Concrete Masonry Unit shall have a U-factor not to exceed 0.690. Wood Framed and Others- The weighted average U-factor of the wall assembly shall not exceed 0.110. Spandrel Panels and Opaque Curtain Wall- The weighted average U-factor of the spandrel panels and opaque curtain wall assembly shall not exceed 0.280. Demising Walls-. The opaque portions of framed demising walls shall meet the requirements of Item A or B below: A. Wood framed walls shall be insulated to meet a U -factor not greater than 0.099. B. Metal Framed walls shall be insulated to meet a U-factor not greater than 0.151. §120.7(c): The opaque portions of floors and soffits that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U-Factor requirements as follows: Raised Mass Floors- Shall have a minimum of 3 inches of lightweight concrete over a metal deck or the weighted average U-factor of the floor assembly shall not exceed 0.269. Other Floors-The weighted average U-factor of the floor assembly shall not exceed 0.071. Washington Park (Retail)10/18/2018