Loading...
BWFE2022-0335DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 eca BUILDING PERMIT Qa�&a CALIFORNIA PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 07/01/2022 ISSUED DATE: 07/21/2022 Permit Type: Wall / Fence Owner: D R HORTON, LOS ANGELES HOLDING Permit Number: BWFE2022-0335 COMPANY 2280 WARDLOW CIR STE 100, CORONA, CA Property Address: 81887 VIA ENCINITAS 92878 APN: 764630051 Applicant: Mario Ornelas Legal Description 2280 Wardlow Circle, Corona, CA 92878 Property Zoning: Contractor: Mario Ornelas / 770126 Valuation: $4,386.00 2280 Wardlow Circle, Corona, CA 92878 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 1/23/25 11:45 am Page 1 of 4 1-311111]1Z"a4 NT,IkI Permit Type: Wall / Fence Permit Number: BWFE2022-0335 Property Address: 81887 VIA ENCINITAS application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 1/23/25 11:45 am Page 2 of 4 111114111►Ma4MYilIII I Permit Type: Wall / Fence Permit Number: BWFE2022-0335 Property Address: 81887 VIA ENCINITAS DR HORTON/111 LF OF 6' GARDEN WALL AND 18LF OF 4' GARDEN WALL *** DR HORTON/111 LF OF 6' GARDEN WALL AND 18LF OF, GARDEN WALL AT NORTH AND EAST PL.[ORCO SPECIFICATIONS] 2019 CALIFORNIA BUILDING CODES. Construction Details Total Block Wall LF 129 I Type Group Sq Ft Value I Invoice No. Fee PERMIT-BWFE2022-031� TECHNOLOGY ENHANCEMENT FEE 5 WALL/FENCE - EA ADDITIONAL 50LF RECORDS MANAGEMENT FEE WALL/FENCE - FIRST 10OLF WALL/FENCE - FIRST 10OLF PC BSAS SB1473 FEE Total for Invoice PERMIT-BWFE2022-0335 Fee Amount Amount Paid $5.00 $5.00 $16.67 $16.67 $11.00 $11.00 $55.58 $55.58 $69.47 $69.47 $1.00 $1.00 Grand Total for Permit $158.72 $158.72 Action Type Start Date End Date 01/29/2024 11:16 ..... ......... Receive Submittal ......... 01/29/2024 11:16 01/29/2024 11:16 Generic Action 01/29/2024 11:16 Generic Action 01/29/2024 11:16 Create Report 01/29/2024 11:16 01/31/2024 0:00 Inspection 02/20/2024 0:00 02/21/2024 13:47 Inspection 01/31/2024 0:00 02/01/2024 12:04 Inspection 02/05/2024 0:00 02/06/2024 12:00 Inspection 02/07/2024 0:00 02/08/2024 14:25 Inspection Inspection Inspection 05/16/2024 16:08 05/16/2024 16:08 Inspection 05/16/2024 16:08 05/16/2024 16:08 Printed: 1/23/25 11:45 am Page 3 of 4 1-31111111]1Z"a4 N IT, IkI Permit Type: Wall / Fence Permit Number: BWFE2022-0335 Property Address: 81887 VIA ENCINITAS Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 1/23/25 11:45 am Page 4 of 4 PROJECT : THE ENCLAVE AT CAPISTRANO — TRACT 31910 NY E SOUTH COAST / INLAND EMPIRE DIVSION 2280 WARDLOW CIRCLE SUITE 100 CORONA, CALIFORNIA 92878 (951)272-9000 04.28.2022 81-887 VIA ENCINITAS LA QUINTA, CALIFORNIA PLOT PLAN - LOT 92 BIOCbi'Jlf T BF UCK CAI AC( E-N T GQLOR TAN SLUMP TAN: SACKER STC*NE RDLLED'wI47RTAiI rA FTMSH VIA ENCINIT S —W w W W w I w w _ — 93.87' a rn w CL (L II , II 18' r� I BWFE2022-0335 LOT 92 --- PLAN 2.2529AR CI TY OF LA QU N TA u BULONGOVISON REVI EYED FCR o; COo= COWLI AN CE g J.ANAYA 071121909.9 r3 a F-777] 11' DR HORTON/111 LF OF U GARDEN + �� WALL AND 18LF OF 4' GARDEN WALL M L AT NORTH AND EAST PL.[ORCO 70.96' SPECIFICATIONS] 2019 CALIFORNIA a 96.71' BUILDING CODES. Part of Wall Permit for Lot 88 42" Tall ORCO Masonry Wall with 2 Pilasters at Courtyard (Finishes per approved Architecture plans) 6' ORCO Masonry wall (ORCO Structural Detail Attached) 1.5' X 42" Tall Courtyard Pilaster 36" wide metal gate Z O QUANTITIES SCALE: 1 "=30' 3 42" Tall ORCO Masonry Courtyard Wall 19 35 4 1.5' Wide x 42" Tall Courtyard Pilasters 2 Item Qty Rear PL(LF) Returns Lek PL Right PL Total LF Total SgFt 1 6' Tall Masonry Wall 0 25 86 111 666 2 36"Metal Gate ORCO COURTYARD WALL FOR 110 MPH 3 SEC. GUST @ EXP C REBAR NOTE: • DO NOT RUN HORIZONTAL REINFORCEMENT THROUGH WALL RETURNS & CONSTRUC77ONJOINTS. • PROVIDE DOWEL & DROP -IN BAR ACCORDING TO DETAIL AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND LB WALL HEIGHT CHANGES, CAP UNIT e 0 v $ EQUAL ORCO 6816 OR 6616 CMU GROUTED ONLY AT VERT. STEEL STUCCO COATED #6 STD JOINT @ 24" O/C A #4 DOWEL @40" O/C @ CENTER OF CMU. 6- EQUAL LEVEL GRADE BOTH SIDES *� N � #4 HORZ COAT 1'--F CONT. I NOTE: DIMEN51ONSARE NOT 70 SCALE. DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF PER SOILS REPORT. 1. EQUIVALENT FLUID PRESSURE= 37PCFPER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 220 PCF PER SOILS REPORT. 4, GROUT STRENGTH = 2000 PSI 0 28 DAYS. 5. REINFORCING STEEL: GRADE 60. 6. SEISMIC-1 SEC. ACMER47TON = 70%. 7. MASONRY COMPRESSION STRENGTH f 'm =1000 PSI GENERAL NOTES: 1. CONCRETE BLOCKSHALL BE MANUFACTURED BY ORCO ASTM C 90. SLUMP BLOCKAND SPL UFACE BLOCKAREACCEPTABLE. Z CONCRETE FOR FOOTING SHALL HAVE COMPRESSIVE STRENGTH Fc = 4500 PSI AT 28 DAYS, WITH WATEWCEMENT RATIO _< 0.45. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE V. 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. S. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CVIV77NUM OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REL 4R SHALL BE SOLID GROUTED. 7. USE TYPES MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8, GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PFA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLEAND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS 9. BLOCKSTEM MAYOEWET-SET 1-112"INTO THEF007ING WHILE THE CONCRETEIS PLASTIC. BLOCKSTFM MAYBE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH MINIMUM COMPAC77ON OF 90%. 11. FIRSTINSPECTION TO BEAFTER F0077NG TRENCHESAREREADY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE SECOND INSPECTION TO BE WHEN THE REQUIRED VER77CAL IS IN PLACEAND THE BLOCK WALL IS READY TO GROUT. 1Z. MAXIMUM CONTROL JOINT SPACING: 30' O/C. ENGINEERING STAMP APPROVAL IS CONDI'RONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DR HoR'roN THE ESTATES @ C4RMELA TRACTS No. 31874-1 & 2 LA QUINTA, CALIFORNIA ORCO SHORT PILASTER FOR 110 MPH 3 SEC. GUST @a EXP C H DESIGN CRITERIA PER 711E 201-0 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE =1500 PSF PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 37 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 220 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC -1 SEC. ACCELERATION = 70%. 7. MASONRYCOMPRES51ON STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BYORCO A57M C 90. SLUMP BLOCKAND SPLTTFACE BLOCKAREAOCEPTABLEE, 2. CONCRETE FOR FOOTING SHALL HAVE COMPRESSIVE STRENGTH PC = 4500 PSI AT 28 DAYS, WITH WATERICEMENT RA770 _< 0.45. PORTLAND CEMENT SHALL CONFORM TOASTM C 150 TYPE V. 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO OPTIONAL CAP ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 3-112' 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN CLR. WHICH ITIS LOG4TED. ORCO 16616 OR 16616 PILASTER CMU SOLID 5, CONCRETE BLOCK SHALL BELAID INA RUNNING BOND PATTERN GROUTED. STUCCO WRHVERTICAL CONTINUITYOFTHE CELLSUNO. COATED. SEE DIAGRAM BELOW 6. ALL BLOCKCELLSSHALL BESOLID GROUTED, 7. USE TYPES MORTAR PROPORTIONED USINGASTM C270 PART #t4 DOWELS W/ 24• MIN. CEMENT TO112PARTLIMETO+112PARTSDAMP, LOOSESAND. EXTENSION INTO CMU. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART J CEMENT TO 3 PARTS SAND (GROUT MAYCIONTAIN 2 PARTS 318" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND L BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD — GROUT FLOWJ. WATER SHALL BEADDED TO PRODUCE GOOD o GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS 9, BLOCKSTEM MAY BE WET SET 1-1/2"INTO THE F007TNG WHILE THE CONCRETFIS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. a 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL KONA MINIMUM COMPAC 7ON OF 90%. 11. FIRST INSPECTION TO BEAF7ER FOO7ING TRENCHES ARE READY #4 HORZ. 6 12, O/C 2 -0 FOR CONCRETE ANOALL REQUIRED STEEL IS 77ED IN PLACE. EACH WAY SECOND INSPECTI01V TO BE WHEN THE REQUIRED VER77CAL IS IN SQUARE FOOTING PLACEAND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EKPANSIOWCONTROL JOINT EACH SIDE OF PILASTER NOTE: DIMENSIONS ARE NOT TO SCALE. WHERE INTERSECTING BLOCK WALLS OCCUR. 16' ORCO 16816 OR 16616 PILASTER CMU STUCCO COATED (SOLID GROUTED)Ll= • �o (2) *4 VERTICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO SCALE ENGINEERING STAMPAPPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DR HORTON THE ESTATES @ G4RMELA TRACTS No. 31874-1 & 2 LA QUINTA, G4LIFORNIA .83660 * EXP. 03/31/2023 CV 47f 0F � & L. i ORCO STANDARD CMU SITE WALLS W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @a EXP C REBAR NO Ohl 160V CRITERIA PER iNE 2DX 9 COC: DO NOT RUN HORIZONTAL REINFORCEMENT THROUGH 1, ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF PER SOILS REPORT. WALL RETURNS & CONSTRUCTION JOINTS. 2, EQUIVALENT FLUID PRESSURE = 37 PCF PER SOILS REPORT. PROVIDE DOWEL & DROP -IN BAR ACCORDING TO DETAIL AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND 3, ALLOWABLE LATERAL PASSIVE PRESSURE = 210 PCF PER SOILS REPORT, WALL HEIGHT CHANGES. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. S REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION - 70%. 7. MASONRY COMPRESSION STRENGTH, f'm = 2000 PSI. CAP UNIT- GENERAL NOTES: 1. CONCRETE BLOCKSHALL BE MANUFACR/RED BYORCO ASTM C 90. SLUMP BLOCKAND SPLITFACE BLOCKAREACCEPTABLEE, 2. CONCRETE FOR FOOTING SHALL HAVE COMPRESSIVE STRENGTH F'c = 4500 PSI AT 28 DAYS, WITH WATERICEMENT RATTO < 0.45. PORTLAND CEMENT SHALL CONFORM TO AS776f C 150 TYPE V. ORCO 6616 CMU 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A GROUTED ONLY @ VERT STEEL 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH #4 - DROP -IN BAR @ 40" 0/C IT IS LOCATED. @ CENTER OF CMU. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VER77CAL CONTINUITY OFTHE CELLS UNO. #6 STD JOINT REINFORCEMENT @ 24" 0/C NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURES, A 112 BLOCK MAY LEFT OLIT @ SWALE GRADE. PROVIDE #4 DOWEL AND #4 DROP -IN BAR ON EACH SIDE OF THE 112 BLOCK DRAIN. #4 DOWEL @ 40" O/C @ f CENTER OF CMU. 00 PROVIDE 24" MIN. LAP. 2 " I MAX. LL- Q l Zt Is � 5 �— #4 HORZ. CONT. / @ 12" O/G Q 6' TO DAYLIGHT Y 8" CONT. #orb: DIMENSIONSARENOTTOSCALE. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BESOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8, GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318"PEA GRAVEL IF WEATHER CONDITIONSARE FAVORABLEAND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS: 9. BLOCK STEM MAYBE WET -SET 1-112"INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE F0077NG. 10, FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER F0077NG TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12 MAXIMUM CONTROL JOINT SPACING: 30' 0/C. DR HORTON THE ESTATES @a CARMELA TRACTS No. 31874-1 & 2 LA QUINTA, CALIFORNIA