Palo Verde TR 32279 BCPR2022-0017 (Plans 1-3) Solar Plans Revision 1SOLAR MASTER PLAN PERMIT PACKAGEWILLIAMS HOMES21080 CENTRE POINTE PARKWAYSANTA CLARITA, CA 91350TRACT / PARCEL #: 32279LA QUINTA, CALIFORNIA 92253PALO VERDEPLAN 1 (3139), 2 (3213), & 3 (3353)6.48 kW, 6.89 kW, & 7.29 kW PHOTOVOLTAIC SYSTEMCODE INFORMATIONAPPLICABLE CODES, LAWS AND REGULATIONS2019 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC)ELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONALEN G IN EER STATEOF CALIFORNIACHIFUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAYLA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®VICINITY MAPPROJECT LOCATIONSHEETSOLAR MASTER PLAN PERMIT PACKAGEREV DESCRIPTIONDATE DBR E V I S I O N SPVA-0GENERAL NOTES:SHEET INDEXSOLAR ARCHITECTURAL DRAWINGSSOLAR STRUCTURAL DRAWINGSSOLAR ELECTRICAL DRAWINGSPVE-1.1ELECTRICAL SINGLE LINE DIAGRAMPVE-2ELECTRICAL DETAILSPVE-4ELECTRICAL DATA & SPECIFICATIONSPVS-1 MOUNTING DETAILS & STRUCTURAL CALCULATIONSPVA-0 COVER SHEETPVA-1PLAN 1 (3139) ELEVATION A & BPVA-2PVA-3PLAN 2 (3213) ELEVATION A & BPLAN 3 (3353) ELEVATION A & BTRANSITIONED TO 405W MODULES& UPDATED SYSTEM SIZE02/26/23COPVE-1.2ELECTRICAL SINGLE LINE DIAGRAMPVE-1.3 ELECTRICAL SINGLE LINE DIAGRAMPVE-5 ELECTRICAL DATA & SPECIFICATIONSPVE-3 ELECTRICAL DETAILSREVISION 1 BCPR2022-0017MODULES CHANGED TO405W WITH SYSTEM SIZESUPDATED08/10/2023NEW SYSTEM ATTRIBUTES:PLAN 1: 6.89kW SOLAR ARRAY - (17)405W SUNPOWER Q.PEAK DUO BLKML-G10+ AC PANELS W/(1) 100A AMPSUBPANEL [340SF]PLAN 2: 6.48kW SOLAR ARRAY - (16)405W SUNPOWER Q.PEAK DUO BLKML-G10+ AC PANELS W/(1) 100A AMPSUBPANEL [320SF]PLAN 3: 7.29kW SOLAR ARRAY - (18)405W SUNPOWER Q.PEAK DUO BLKML-G10+ AC PANELS W/(1) 100A AMPSUBPANEL [360SF]
ELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350SOLAR MASTER PLAN PERMIT PACKAGEDRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-24CHRISTIAN OPEÑALEGENDS:(3') WIDE ACCESS PATH (PITCHED ROOF)(4') WIDE ACCESS PATH (FLAT ROOF)PLAN TYPE OPTION DESCRIPTION010203---------------------------------------------------------------------------------------------------------0405----------------------------------------------------------------------PLAN 1 (3139) - ELEVATION A - S-TILENOTE :- ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.- FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT,MECHANICAL VENT.BASE SQUARE FOOTAGE: 3,139 SQ. FT.SLD REFERENCEPVE-1.2SUNPOWER 132 CELLS AC MODULESMODEL NO.NOMINAL POWER (Pnom)405WSYSTEM SIZEQ.PEAK DUO BLK ML-G10+ (405)QUANTITY: 176.89 kWSLD REFERENCEPVE-1.2SLD REFERENCEPVE-1.2LAYOUT 1LAYOUT 2LAYOUT 3PLAN 1 (3139) - ELEVATION B - S-TILESLD REFERENCEPVE-1.2SLD REFERENCEPVE-1.2SLD REFERENCEPVE-1.2LAYOUT 1LAYOUT 2LAYOUT 3BACK FRONT OF HOUSE : 285° - 120°BACK FRONT OF HOUSE : 285° - 120°LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30°LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30°FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINTTRANSITION BOXTRANSITION BOXTRANSITION BOX(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINTTRANSITION BOXTRANSITION BOXTRANSITION BOXTHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®PVA-1SHEETREV DESCRIPTION DATE DBR E V I S I O N SPLAN 1 (3139) ELEVATION A & BTRANSITIONED TO 405W MODULES02/23/23CO& UPDATED SYSTEM SIZE08/10/2023ALL SYSTEM MUST BE ORIENTED 105-300 DEGREE AZIMUTH
LEGENDS:(3') WIDE ACCESS PATH (PITCHED ROOF)(4') WIDE ACCESS PATH (FLAT ROOF)PLAN TYPE OPTION DESCRIPTION010203---------------------------------------------------------------------------------------------------------0405----------------------------------------------------------------------PLAN 2 (3213) - ELEVATION A - S-TILENOTE :- ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.- FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT,MECHANICAL VENT.BASE SQUARE FOOTAGE: 3,213 SQ. FT.SLD REFERENCEPVE-1.1SUNPOWER 132 CELLS AC MODULESMODEL NO.NOMINAL POWER (Pnom)405WSYSTEM SIZEQ.PEAK DUO BLK ML-G10+ (405)QUANTITY: 166.48 kWSLD REFERENCEPVE-1.1LAYOUT 1LAYOUT 2PLAN 2 (3213) - ELEVATION B - S-TILESLD REFERENCEPVE-1.1SLD REFERENCEPVE-1.1LAYOUT 1LAYOUT 2LEFTFRONT OF HOUSE : 15° - 210°LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30°RIGHT FRONT OF HOUSE : 195° - 30°FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)ROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRID(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINTTRANSITION BOXTRANSITION BOX(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINTTRANSITION BOXTRANSITION BOXELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350SOLAR MASTER PLAN PERMIT PACKAGEDRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-24CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®SHEETREV DESCRIPTION DATE DBR E V I S I O N SPVA-2PLAN 2 (3213) ELEVATION A & BTRANSITIONED TO 405W MODULES02/23/23CO& UPDATED SYSTEM SIZE08/10/2023ALL SYSTEM MUST BE ORIENTED 105-300 DEGREE AZIMUTH
LEGENDS:(3') WIDE ACCESS PATH (PITCHED ROOF)(4') WIDE ACCESS PATH (FLAT ROOF)PLAN TYPE OPTION DESCRIPTION010203---------------------------------------------------------------------------------------------------------0405----------------------------------------------------------------------PLAN 3 (3353) - ELEVATION A - S-TILENOTE :- ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.- FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT,MECHANICAL VENT.BASE SQUARE FOOTAGE: 3,353 SQ. FT.SLD REFERENCEPVE-1.3SUNPOWER 132 CELLS AC MODULESMODEL NO.NOMINAL POWER (Pnom)405WSYSTEM SIZEQ.PEAK DUO BLK ML-G10+ (405)QUANTITY: 187.29 kWSLD REFERENCEPVE-1.3SLD REFERENCEPVE-1.3LAYOUT 1LAYOUT 2LAYOUT 3PLAN 3 (3353) - ELEVATION B - S-TILESLD REFERENCEPVE-1.3SLD REFERENCEPVE-1.3SLD REFERENCEPVE-1.3LAYOUT 1LAYOUT 2LAYOUT 3BACK FRONT OF HOUSE : 285° - 120°BACK FRONT OF HOUSE : 285° - 120°LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30°LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30°FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)ROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDTRANSITION BOXTRANSITION BOXTRANSITION BOXROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINT(E) SERVICE POINT ANDUTILITY METERINGUTILITY AC DISCONNECT SWITCH(OUTSIDE GARAGE WITHIN SIGHTFROM THE MAIN SERVICE PANEL)(N) LOAD CENTER(INSIDE GARAGE)TO ELECTRICUTILITY GRIDROOF ACCESS POINTROOF ACCESS POINTTRANSITION BOXTRANSITION BOXTRANSITION BOXELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350SOLAR MASTER PLAN PERMIT PACKAGEDRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-24CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®SHEETREV DESCRIPTION DATE DBR E V I S I O N SPVA-3PLAN 3 (3353) ELEVATION A & BTRANSITIONED TO 405W MODULES02/23/23CO& UPDATED SYSTEM SIZE08/10/2023ALL SYSTEM MUST BE ORIENTED 105-300 DEGREE AZIMUTH
PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAYLA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®SHEETREV DESCRIPTION DATE DBR E V I S I O N SPVS-108/10/2023
TAG12345SOURCE CIRCUIT TRANSITION BOX(N) LOAD CENTERPV PRODUCTION METERSEPARATE AC DISCONNECTDESCRIPTIONSOLAR AC MODULE / BRANCH34(N) LOAD CENTERPV PRODUCTION METERELECTRICAL NOTES1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TOGROUND AT COUPLINGS ON BOTH ENDS.2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FORGROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER,INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICALEQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROMSUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITHMEYERS HUBS TO BE USED.3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,CRIMPS, ETC.4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADIIREQUIREMENTS.5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TOBE INSTALLED.6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITYREQUIREMENTS.7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL ANDATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NOOTHER CONDUCTORS RUNNING THROUGH IT.11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLEDBY A THIRD PARTY.12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIREUPSIZE.13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE.14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIREDUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGEDROP15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOTREQUIRED.NOTE :xSUNPOWER 15A MONITORING BREAKER CAN BE RELOCATEDTO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSEFOR CONSTRUCTION FEASIBILITY.xBELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BEINSTALLED IF THE HOMEOWNER SIGNS A SPECIFICCONTRACT WITH SUNPOWER.xSUNPOWER MONITORING SYSTEMxAS DC POWER IS INTERNAL TO THE MODULE, GROUNDINGELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAYIS NOT REQUIRED.12CONDUCTOR / CONDUIT SCHEDULEDESCRIPTION &CONDUCTOR TYPECONDUCTORSIZE(AWG)21SUNPOWER PROVIDED AC MODULES EXTENSIONCABLE, LISTED AS AN ASSEMBLYNUMBEROFCONDUCTORSCONDUIT/ CABLETYPECONDUIT SIZE(WHEN NEEDED)#12TYPE-ER, PERBRANCH CIRCUIT--WITH EGCABTAGMICROINVERTERFIGURE A: SINGLE LINE DIAGRAM - 6.48 KWDCUTILITYBIDIRECTIONALMETER(NOT CENTER-FED)INCOMING SOURCE FEEDHMCB (E)MAIN SERVICE PANEL200A, 120/240V, 1PH, 3WGNDEXISTINGGNDTO HOUSELOADSBREAKERS SHALL BEINSTALLED OPPOSITEEND OF THE MAINBREAKER200A, 2P40A,2PGND3NOTE:FOR SOLAR PHOTOVOLTAIC ONLY.NO ADDITIONAL LOADS TO BE APPLIED(N)LOAD CENTER100A OR EQUIVALENT, 120/240V, 1PH20A, 2P20A, 2PEATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES5NM CABLE OR EQINSTALLED IN WALL CAVITY--EGC BARE CUCU-NM-B 31GNDCCUTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC#8#10OPTIONALETHERNETCONNECTION TODSL/CABLE MODEMCAT5eCURRENTTRANSFORMERS (100A)INSTALLED ON THECUSTOMER SIDE OFTHE PANEL1#14NM CABLE OR EQINSTALLED IN WALL CAVITY#22NMFCCU-NM-BAWG TWISTED PAIREGC BARE CU3INSTALLED IN WALLCAVITY1/2"--PRODUCTION CURRENTTRANSFORMERS (100A)SUNPOWERMONITORINGPVS6E#143DEED#615A, 2P2ADCACDCAC1SUNPOWER MODULESAC MODULEEXTENSION CABLEFMCINSTALLED IN WALL CAVITY3/4"EGC: THWN-2THWN-2B8 AC MODULESBRANCH CIRCUIT #28 AC MODULESBRANCH CIRCUIT #1Q.PEAK DUO BLK ML-G10+ (405)#10#10IQ7HS-66-M-US (240)ATTICROOFTOPELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONSHEETREV DESCRIPTION DATE DBR E V I S I O N SPVE-1.1REVISED CONDUIT SCHEDULE AS PER INSPECTOR NOTES11/28/22KLBTRANSITIONED TO 405W MODULES& UPDATED SYSTEM SIZE02/26/23CO08/10/2023
TAG12345SOURCE CIRCUIT TRANSITION BOX(N) LOAD CENTERPV PRODUCTION METERSEPARATE AC DISCONNECTDESCRIPTIONSOLAR AC MODULE / BRANCH34(N) LOAD CENTERPV PRODUCTION METERELECTRICAL NOTES1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TOGROUND AT COUPLINGS ON BOTH ENDS.2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FORGROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER,INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICALEQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROMSUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITHMEYERS HUBS TO BE USED.3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,CRIMPS, ETC.4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADIIREQUIREMENTS.5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TOBE INSTALLED.6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITYREQUIREMENTS.7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL ANDATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NOOTHER CONDUCTORS RUNNING THROUGH IT.11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLEDBY A THIRD PARTY.12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIREUPSIZE.13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE.14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIREDUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGEDROP15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOTREQUIRED.NOTE :xSUNPOWER 15A MONITORING BREAKER CAN BE RELOCATEDTO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSEFOR CONSTRUCTION FEASIBILITY.xBELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BEINSTALLED IF THE HOMEOWNER SIGNS A SPECIFICCONTRACT WITH SUNPOWER.xSUNPOWER MONITORING SYSTEMxAS DC POWER IS INTERNAL TO THE MODULE, GROUNDINGELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAYIS NOT REQUIRED.12CONDUCTOR / CONDUIT SCHEDULEDESCRIPTION &CONDUCTOR TYPECONDUCTORSIZE(AWG)21SUNPOWER PROVIDED AC MODULES EXTENSIONCABLE, LISTED AS AN ASSEMBLYNUMBEROFCONDUCTORSCONDUIT/ CABLETYPECONDUIT SIZE(WHEN NEEDED)#12TYPE-ER, PERBRANCH CIRCUIT--WITH EGCABTAGMICROINVERTERFIGURE A: SINGLE LINE DIAGRAM - 6.89 KWDCUTILITYBIDIRECTIONALMETER(NOT CENTER-FED)INCOMING SOURCE FEEDHMCB (E)MAIN SERVICE PANEL200A, 120/240V, 1PH, 3WGNDEXISTINGGNDTO HOUSELOADSBREAKERS SHALL BEINSTALLED OPPOSITEEND OF THE MAINBREAKER200A, 2P40A,2PGND3NOTE:FOR SOLAR PHOTOVOLTAIC ONLY.NO ADDITIONAL LOADS TO BE APPLIED(N)LOAD CENTER100A OR EQUIVALENT, 120/240V, 1PH20A, 2P20A, 2PEATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES5NM CABLE OR EQINSTALLED IN WALL CAVITY--EGC BARE CUCU-NM-B 31GNDCCUTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC#8#10OPTIONALETHERNETCONNECTION TODSL/CABLE MODEMCAT5eCURRENTTRANSFORMERS (100A)INSTALLED ON THECUSTOMER SIDE OFTHE PANEL1#14NM CABLE OR EQINSTALLED IN WALL CAVITY#22NMFCCU-NM-BAWG TWISTED PAIREGC BARE CU3INSTALLED IN WALLCAVITY1/2"--PRODUCTION CURRENTTRANSFORMERS (100A)SUNPOWERMONITORINGPVS6E#143DEED#615A, 2P2ADCACDCAC1SUNPOWER MODULESAC MODULEEXTENSION CABLEB8 AC MODULESBRANCH CIRCUIT #29 AC MODULESBRANCH CIRCUIT #1Q.PEAK DUO BLK ML-G10+ (405)#10#10IQ7HS-66-M-US (240)ATTICROOFTOPFMCINSTALLED IN WALL CAVITY3/4"EGC: THWN-2THWN-2ELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONSHEETREV DESCRIPTION DATE DBR E V I S I O N SPVE-1.2REVISED CONDUIT SCHEDULE AS PER INSPECTOR NOTES11/28/22KLBTRANSITIONED TO 405W MODULES& UPDATED SYSTEM SIZE02/26/23CO08/10/2023
TAG12345SOURCE CIRCUIT TRANSITION BOX(N) LOAD CENTERPV PRODUCTION METERSEPARATE AC DISCONNECTDESCRIPTIONSOLAR AC MODULE / BRANCH34(N) LOAD CENTERPV PRODUCTION METERELECTRICAL NOTES1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TOGROUND AT COUPLINGS ON BOTH ENDS.2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FORGROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER,INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICALEQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROMSUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITHMEYERS HUBS TO BE USED.3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,CRIMPS, ETC.4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADIIREQUIREMENTS.5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TOBE INSTALLED.6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITYREQUIREMENTS.7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL ANDATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NOOTHER CONDUCTORS RUNNING THROUGH IT.11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLEDBY A THIRD PARTY.12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIREUPSIZE.13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE.14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIREDUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGEDROP15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOTREQUIRED.NOTE :xSUNPOWER 15A MONITORING BREAKER CAN BE RELOCATEDTO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSEFOR CONSTRUCTION FEASIBILITY.xBELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BEINSTALLED IF THE HOMEOWNER SIGNS A SPECIFICCONTRACT WITH SUNPOWER.xSUNPOWER MONITORING SYSTEMxAS DC POWER IS INTERNAL TO THE MODULE, GROUNDINGELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAYIS NOT REQUIRED.12CONDUCTOR / CONDUIT SCHEDULEDESCRIPTION &CONDUCTOR TYPECONDUCTORSIZE(AWG)21SUNPOWER PROVIDED AC MODULES EXTENSIONCABLE, LISTED AS AN ASSEMBLYNUMBEROFCONDUCTORSCONDUIT/ CABLETYPECONDUIT SIZE(WHEN NEEDED)#12TYPE-ER, PERBRANCH CIRCUIT--WITH EGCABTAGMICROINVERTERFIGURE A: SINGLE LINE DIAGRAM - 7.29 KWDCUTILITYBIDIRECTIONALMETER(NOT CENTER-FED)INCOMING SOURCE FEEDHMCB (E)MAIN SERVICE PANEL200A, 120/240V, 1PH, 3WGNDEXISTINGGNDTO HOUSELOADSBREAKERS SHALL BEINSTALLED OPPOSITEEND OF THE MAINBREAKER200A, 2P40A,2PGND3NOTE:FOR SOLAR PHOTOVOLTAIC ONLY.NO ADDITIONAL LOADS TO BE APPLIED(N)LOAD CENTER100A OR EQUIVALENT, 120/240V, 1PH20A, 2P20A, 2PEATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES5NM CABLE OR EQINSTALLED IN WALL CAVITY--EGC BARE CUCU-NM-B 31GNDCCUTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC#8#10OPTIONALETHERNETCONNECTION TODSL/CABLE MODEMCAT5eCURRENTTRANSFORMERS (100A)INSTALLED ON THECUSTOMER SIDE OFTHE PANEL1#14NM CABLE OR EQINSTALLED IN WALL CAVITY#22NMFCCU-NM-BAWG TWISTED PAIREGC BARE CU3INSTALLED IN WALLCAVITY1/2"--PRODUCTION CURRENTTRANSFORMERS (100A)SUNPOWERMONITORINGPVS6E#143DEED#615A, 2P2ADCACDCAC1SUNPOWER MODULESAC MODULEEXTENSION CABLEB9 AC MODULESBRANCH CIRCUIT #29 AC MODULESBRANCH CIRCUIT #1Q.PEAK DUO BLK ML-G10+ (405)#10#10IQ7HS-66-M-US (240)ATTICROOFTOPFMCINSTALLED IN WALL CAVITY3/4"EGC: THWN-2THWN-2ELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONSHEETREV DESCRIPTION DATE DBR E V I S I O N SPVE-1.3REVISED CONDUIT SCHEDULE AS PER INSPECTOR NOTES11/28/22KLBTRANSITIONED TO 405W MODULES& UPDATED SYSTEM SIZE02/26/23CO08/10/2023
FIGURE 1: ELECTRICAL SIGNAGES/STICKERSWARNINGPOWER SOURCE OUTPUT CONNECTIONDO NOT RELOCATETHIS OVERCURRENT DEVICExxxTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUTDOWNPV SYSTEM AND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPED WITHRAPID SHUTDOWNRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEMxxxFIGURE 2: WIRING ROOF PENETRATION CROSS SECTIONELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®xxxxPHOTOVOLTAIC SYSTEMAC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:AMPSVOLTSxxxAMPSVOLTSPHOTOVOLTAIC POINT OFINTERCONNECTIONWARNING: ELECTIC SHOCK HAZARD. DO NOTTOUCH TERMINALS. TERMINALS ON BOTH THELINE AND LOAD SIDE MAY BE ENERGIZEDIN THE OPEN POSITION. FOR SERVICEDE-ENERGIZE BOTH SOURCE AND MAIN BREAKERPV POWER SOURCEMAXIMUM RATED AC OUTPUT CURRENT:MAXIMUM OPERATING AC VOLTAGE:xxPHOTOVOLTAIC SYSTEMAC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:AMPSVOLTSAMPSVOLTSPHOTOVOLTAIC POINT OFINTERCONNECTIONWARNING: ELECTIC SHOCK HAZARD. DO NOTTOUCH TERMINALS. TERMINALS ON BOTH THELINE AND LOAD SIDE MAY BE ENERGIZEDIN THE OPEN POSITION. FOR SERVICEDE-ENERGIZE BOTH SOURCE AND MAIN BREAKERPV POWER SOURCEMAXIMUM RATED AC OUTPUT CURRENT:MAXIMUM OPERATING AC VOLTAGE:PHOTOVOLTAIC SYSTEMAC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:AMPSVOLTSAMPSVOLTSPHOTOVOLTAIC POINT OFINTERCONNECTIONWARNING: ELECTIC SHOCK HAZARD. DO NOTTOUCH TERMINALS. TERMINALS ON BOTH THELINE AND LOAD SIDE MAY BE ENERGIZEDIN THE OPEN POSITION. FOR SERVICEDE-ENERGIZE BOTH SOURCE AND MAIN BREAKERPV POWER SOURCEMAXIMUM RATED AC OUTPUT CURRENT:MAXIMUM OPERATING AC VOLTAGE:25.6024025.6024027.2024028.8024027.2024028.802406.48 kW6.48 kW6.89 kW7.29 kW6.89 kW7.29 kWPHOTOVOLTAIC SYSTEM COMBINERPANEL: DO NOT ADD LOADSxAC SOLAR DISCONNECTxSHEETREV DESCRIPTION DATE DBR E V I S I O N SELECTRICAL DETAILSDRIVEWAYPVE-2TYPICAL DIRECTORY PLACARDNOTE:CUSTOMIZED PLACARD WILL BE PROVIDEDFOR EACH LOT(UNIT)NMAIN SERVICEPANELLOAD CENTERPHOTOVOLTAICAC DISCONNECTPHOTOVOLTAICARRAY ON ROOFPOWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECTSLOCATED AS SHOWN:CAUTION:DRIVEWAYREVISED AS PER INSPECTION NOTES11/28/22KLBTRANSITIONED TO 405W MODULES& UPDATED SYSTEM SIZE02/26/23CO08/10/2023
ELECTRICALE22659Exp. 03-31-23REGISTERED PROFESSIONAL EN G IN EER STATE OF CALIFORNIACHI FUNG LE UNG PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAY LA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®xxxxxSHEETREV DESCRIPTION DATE DBR E V I S I O N SPVE-3ELECTRICAL DETAILSTRANSITIONED TO 405W MODULES& UPDATED SYSTEM SIZE02/26/23CO08/10/2023
CURRENT TRANSFORMER SPECIFICATION SHEETPVS6 DATASHEET 1PVS6 DATASHEET 2PVS6 INSTALLATION INSTRUCTIONS 2PVS6 INSTALLATION INSTRUCTIONS 1Q-CABLE DATA SHEET 1/2 Q-CABLE DATA SHEET 2/2ENPHASE DATA SHEET 1/2 ENPHASE DATA SHEET 2/2INVISIMOUNT DATA SHEET 1/2 INVISIMOUNT DATA SHEET 2/2CONDUCTOR AND OCP SIZING TABLEPV MODULE SPECIFICATION SHEET 1/2 PV MODULE SPECIFICATION SHEET 2/2CERTIFICATE OF COMPLIANCECLASS A FIRE RATING LISTING PG 1/3CLASS A FIRE RATING LISTING PG 2/3CLASS A FIRE RATING LISTING PG 3/3PALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAYLA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®ELECTRICALE22659Exp. 03-31-23REGISTEREDPROFESSIONALEN G IN E ER STATEOFCALIFORNIACHIFUNGLE UNG SHEETREV DESCRIPTION DATE DBR E V I S I O N SELECTRICAL DATA & SPECIFICATIONSPVE-TRANSITIONED TO 405W MODULES02/23/23CO& UPDATED SYSTEM SIZE
TECHNICAL DATA SHEET 6.0" STANCHIONRAIL-MOUNTED JUNCTION BOX 1/2 RAIL-MOUNTED JUNCTION BOX 2/2UNIVERSAL INVISIMOUNT INSTALLATION GUIDEAC DISCONNECT DATA SHEETPALO VERDETRACT / PARCEL #: 32279WILLIAMS HOMES21080 CENTRE POINTE PARKWAYLA QUINTA, CALIFORNIA 92253SANTA CLARITA, CA 91350DRAWN BYPROJECT NO.DATE DRAWNCOMMUNITY ID C003125D-01254012023-02-26CHRISTIAN OPEÑATHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF THESUNPOWER CORPORATION IS STRICTLY FORBIDDEN.C O R P O R A T I O N , S Y S T E M S1 4 1 4 H A R B O U R W A Y S O U T HR I C H M O N D , C A 9 4 8 0 4(5 1 0 ) 5 4 0 - 0 5 5 0C A L I C E N S E # 8 9 0 8 9 5®ELECTRICALE22659Exp. 03-31-23REGISTEREDPROFESSIONALEN G IN E ER STATEOFCALIFORNIACHIFUNGLE UNG SHEETREV DESCRIPTION DATE DBR E V I S I O N SELECTRICAL DATA & SPECIFICATIONSPVE-TRANSITIONED TO 405W MODULES02/23/23CO& UPDATED SYSTEM SIZE