12-0446 (AR) Title 24t
`I
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Miller Residence
52-860 Avenida Obregon
La Quinta, Ca 92253
RECEIvED
JUN 14 2012
Project Designer:
0 ff M T 0 W ff
MAY 25 2012 IU
BY: I ey
Report Prepared by:
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
Job Number:
Ig041212
Date:
5/25/2012
CITY O'ILA QUANTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE:►BY_
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and -Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I EnergyPro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-05-25706:27:55 ID: Ig041212
.TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
1
2
3
10
13
EnergyPro 5.1 by EnergySoft Job Number: ID: Ig041212 User Number: 5732 1
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Miller Residence
Building Type O'Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
5/25/2012
Project Address
52-860 Avenida Obregon La, Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,803
Addition
465
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavit f12) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 1,338 Perim = 0' Existing
Wall Wood Framed
None 879 Existing
Door Opaque Door
None '20 Existing
Roof Wood Framed Attic
R-11 1,337 Existing
Slab Unheated Slab -on -Grade
None 465 Perim = 0' New
Wall Wood Framed
R-15 520 New
Roof Wood Framed Attic
R-38 435 Radiant Barrier New
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidef ins Shades Status
Right (S) 49.0 0.710
0.73 none none Bug Screen Removed
Right (S) 15.0 0.710
0.73 none none Bug Screen Existing
Rear (E) 32.6 0.710
0.73 none none Bug Screen Existing
Left (N) 40.0 0.710
0.73 none none Bug Screen Existing
Left (N) 4.0 0.710
0.73 none none Bug Screen Removed
Front (W) 32.0 0.710
0.73. none none Bug Screen Existing
Skylight 0.5 0.430
0.30 none none None New
Skylight 0.5 0.430
0.30 none none None New
Right (S) 4.0 0.510
0.66 none none Bug Screen New
Rear (E) 3.0 0.510
0.66 none none Bug Screen New
Left (N) 68.0 0.510
0.34 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Electric 3.40 HSPF
Split Air Conditioner 12.0 SEER Setback Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic, Ceiling.lns, vented 6.0 Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by EnergySoft User Number. 5732
RunCode: 2012-05-25706:27:55 ID: 1q041212
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name '
Miller Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
5/25/2012
Project Address
52-860 Avenida Obregon La Quinta
California Energy Climate Zone
CA Climate Zone, 15
Total Cond. Floor Area
1,803
Addition
465
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST .
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Leff (N) 10.0 0.510 0.66 none none . Bug Screen New
Front (lM 8.0 0.510 0.66 none none Bug Screen New
Front (M 20.0 0.360 0.35 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-05-25706:27:55 ID: 1 041212
Page 4 of 13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Miller Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family 621 Existing+ Addition/Alteration
Date
5/25/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Existing Electric Heat Default FAU/AC 2006 and Later has an HSPF less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 1,338.0 R2 Exposed Slab Floor, 3.500" thick at Existing
The Existing Wall RIMS, 37.66' x 8' has a U -Factor greater than the Vintage Defaults. Field verification is required.
The Existing Wall Re/E, 28.25' x 8' has a U -Factor greater than the Vintage Defaults. Field verification is required.
The Existing Wall Le/N, 30.41' x 8' has a U -Factor greater than the Vintage Defaults. Field verification is required.
The Existing Wall FdW, 31' x 8' has a LI -Factor greater than the Vintage Defaults. Field verification is required.
The Existing Roof Roof has a U -Factor greater than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 465.0 ft= Exposed Slab Floor, 4.000" thick at Addition
The Roof R-38 Roof Attic w/Radiant Barrier includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as
specified in Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector. must receive a
completed CF -413 form for each of the measures listed below for final to be given.
EnergyPro 5.1 by EnerqySoft User Number. 5732 RunCode: 2012-05-25T06:27:55 ID: 1041212 Page 5 of 13
PERFORMANCE CERTIFICATE: Residential, (Part 3 of 5) CF -1 R
Project Name
Building Type 0 Single Family ❑ Addition Alone
Date
Miller Residence
❑ Multi Family 0 Existing+ Addition/Alteration
5/25/2012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 19.55 17.33 2.22
Space Cooling 142.35 136.93 5.42
Fans 30.12 28.84 1.27
Domestic Hot Water 27.55 27.55 0.00
Pumps 0.00 0.00 0.00
Totals 219.56 210.66 8.91
Percent Better Than Standard: 4.1%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (K9 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (►M 401 60
Fuel Available at Site: Natural Gas (N) 427 118
Raised Floor Area: 0 (E) 397 36
Slab on Grade Area: 1,803 (S) 427 19
Average Ceiling Height: 8.0 Roof 1,773 1
Fenestration Average U -Factor: 0.60 TOTAL: 234
Average SHGC: 0.58 Fenestration/CFA Ratio: 13.0%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Santiago Lopez-Ocampo
P.O.Box 1018 5/25/2012
Address Name
City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building, design- represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company
5/ Address Z4I
Name
City/State/Zip Phone Signed License # ate
Ener Pro 5.1 by EnerqySoft User Number: 5732 RunCoile: 2012-05-25706:27:55 ID: 1q041212 Pa e 6 of 13
CERTIFICATE OF COMPLIANCE:
Residential
Part 4 of 5) CF -1 R
Project Name
Miller Residence
Building Type m Single Family 0 Addition Alone
❑ Multi Family 93 Existing+ Addition/Alteration
Date
1512512012
OPAQUE SURFACE DETAILS
Surface
Type Area
Ll- Insulation Joint Appendix
Factor CavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
1,338
0.730 None
0
180 Existing 4.4.7-A1
Existing
Wall
286
0.356 None
180
90 Existing 4.3.1-A1
Existing
Wall
193
0.356 None
90
90 Existing 4.3.1-A1
Existing
Wall
203
0.356 None
1 0
90 1 Existing 4.3.1-A1
Existing
Door
17
0.500 None
0
90 Remove 4.5.1-A4
Existing
Wall
196
0.356 None
270
90 Existing 4.3.1-A1
Existing
Door
20
0.500 None
270
90 Existing 4.5.1-A4
Existing
Roof
1,337
0.079 R-11
0
0 Existing 4.2.1-A2
Existing
Slab
465
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
121
0.095 R-15
180
90 New 4.3.1-A4
Addition
Wall
168
0.095 R-15
90
90 New 4.3.1-A4
Addition
Wall
105
0.095 R-15
0
90 New 4.3.1-A4
Addition
Wall
125
0.095 R-15
270
90 New 4.3.1-A4
Addition
Roof
1 435
0.025 R-38
0
16 New 4.2.1-A21
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
T Window
40.0 0.710 Default
0.73 Default
180 Removed
Double Metal Clear
Existing
er
Window
9.0 0.710 Default
0.73 Default
180 Removed
Double Metal Clear
Existing
Window
5.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing
Window
10.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing
Window
10.01 0.710 Default
0.73 Default
1 90 Existing
Double Metal Clear
Existing
Window
22.6 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing
Window
40.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing
8
Window
4.0 0.710 Default
0.73 Default
0 Removed
Double Metal Clear
Existing
Window
12.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing
Window
20.0 0.710 Default
0.73 1 Default
270 Existing
Double Metal Clear
Existing
Skylight
0.5 0.430 NFRC
0.30 NFRC
0 New
Solatube
Existing
Skylight
0.5 0.430 NFRC
0.30 NFRC
0 New
Solatube
Existing
Window
4.0 0.510 NFRC
0.66 NFRC
180 New
Pittsburgh Coming GB 12x12
Addition
W
Window
1.0 0.510 NFRC
0.66 NFRC
90 New
Pittsburgh Coming GB 12x12
Addition
indow
1.0 0.510 NFRC
0.66 NFRC
90 New
Pittsburgh Coming GB 12x12
Addition
Window
1.0 0.510 NFRC
0.66 NFRC90
New
Pittsburgh Coming GB 12x12
Addition
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hclt Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
None
1.00
12
None
1.00
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
Ener
Pro 5.1 by EnergySoft User Number: 5732 RunCode: 2012-05-25T06:27:55 ID: 1q041212
Page 7 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Miller Residence
Building Type O'Single,Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
5/25/2012
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
U -Factor SHGCz
Azm Status Glazing Type Location/Comments
Window 14.0
0.510 NFRC 0.34 NFRC 0 New General Aluminum Company Addition
Window 40.0
0.510 NFRC 0.34 NFRC 0 New General Aluminum Company Addition
Window 6.0
0.510 NFRC 0.66 NFRC 0 New Pittsburgh Coming GB 12x12 Addition
Window 14.0
0.510 NFRC 0.34 NFRC 0 New General Aluminum Company Addition
Window 4.01
0.510 NFRC 0.66 NFRC 0 New Pittsburgh Corning GB 12x12 Addition
.2,e Window 4.0
0.510 NFRC 0.66 NFRC 270 New Pittsburgh Coming GB 12x12 Addition
Window 4.0
0.510 NFRC 0.66 NFRC 270 New Pittsburgh Coming GB 12x12 Addition
Window 20.0
0.360 NFRC 0.35 NFRC 270 New Jeld-Wen, Steel Fr.Dr. Addition
(1) Ll -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window
SHGC Hat FWd
Ove hang Left Fin Ri ht Fin
Len H t LExt RExt Dist Len H t Dist Len H t
17 Bug Screen
0.76
18 Bug Screen
0.76
19 Bug Screen
0.76
20 Bug Screen
0.76
21 Bug Screen
0.76
22 Bug Screen
0.76
23 Bug Screen
0.76
24 Bug Screen
0.76
EnergyPro 5.1 by Ener Soft
User Number: 5732
RunCode: 2012-05-25706:27:55 ID: 1 041212 Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5)
CF -1 R
Project Name
Miller Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration
Date
5/25/2012
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered'. Removed Volume
Year Built
HVAC System Existing
1,338
10,704 2000
Addition
465
3,720
Totals 1 4661 1,338 01 01
1
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Co olind Type Min. Eff. Thermostat Type
Status
HVAC System 1 Electric
3.40 HSPF Split Air Conditioner 12:0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Coolin Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 6.0
❑
Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE*
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
A O Smith Water Products
1
Small Elec.
Kitchen Pipe Ins
15,359
50
0.91
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length'
(ft)
C
_ o
Q —
System Name
Pipe
Len th
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried'
Ell
EnergyPro 5.1 by Ener Sof User Number., 5732
RunCode: 2012-05-25706:27:55 ID: 1041212
Page 9 of 13
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Miller Residence
Date
5/25/2012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
§116(a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor; certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are "caulked and sealed.
118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§1"18(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation "material alone without facings is no greater than 0.3%; water vapor permeance
rate is no areater than 2.0perm/inch and shall be protected from physical dama a and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Lo 'Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is.at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and "Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and "all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where "the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a"vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode:.2012-05-25T06:27:55 ID: Ig041212 Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Miller Residence
5/25/2012
§150(m)1: All air -distribution system ducts andplenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant.that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or, tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture,. equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible'method.of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe -between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have. a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat -Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwellingunits larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2012-05-25706:27:55 ID: 18041212 Page 11 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
Miller Residence
5/25/2012
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires.recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label-that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
�be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoR User Number: 5732 RunCode: 2012-05-25706:27:55 ID: Ig041212 Page 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Miller Residence
Date
5/25/2012
System Name
HVAC System
Floor Area
1,803
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,821
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 0
34,878
2,387
831
31,077
Total Output Btuh 0
0
Output Btuh/s ft 0.0
2,380
1,793
Cooling System
0
0
Output per System 1
0
0
0
0
Total Output Btuh 1
0
2,380
39,638
2,387
0
Total Output Tons 0.0
1,793
Total Output (Btuh/s ft) 0.0
Total Output s ft/Ton 21,636,000.0
34,662
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Default FAU/AC 2006 and Later
1
0
0
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
0
Jan 1 AM
Outside Air % 0.0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
Outside Air cfm/s ft 0.00
I
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak)
26 OF
Outside Air
0 cfm
66 OF
66 OF 105 OF
Heating Coil
103 OF
ROOM
i
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112178 °F
Outside Air
0 cfm
77/63°F
14
77 / 63 OF 55 / 54 OF
i
Cooling Coil
57 / 55 OF
49.0% ROOM
75/62°F
EnergyPro 5.1 by EnergySoft User Number. 5732 RunCode: 2012-05-25706:27:55
ID: Ig041212 Page 13 of 13