BPOL2024-0023BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 01/31/2024
ISSUED DATE: 02/01/2024
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Pool
49723 AVENIDA MONTERO
BPOL2024-0023
646182021
Lot 13 MB 58/20 TR 3448
$35,000.00
RL, 13
Owner:HOPE RADER
Applicant:AZURE POOLS & SPAS INC
PO BOX 10641, PALM DESERT, CA 92255
Contractor:AZURE POOLS & SPAS INC / 802919
PO BOX 10641, PALM DESERT, CA 92255
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 2/13/25 10:16 am Page 1 of 3
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0023
49723 AVENIDA MONTERO
BUILDING PERMIT
REMODEL TO EXISTING POOL AT FRONT YARD. ADD TANNING SHELF AND SPA AT EXISTING POOL [POOL ENGINEERING INC.] THIS
PERMIT DOES NOT INCLUDE
REMODEL TO DETACHED SPA'S OR REPLACEMENT OF EQUIPMENT. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT
PRE-PLASTER INSPECTION.
2022 CALIFORNIA BUILDING CODE.
REVISION 1 - REPLACE EXISTING POOL EQUIPMENT [POOL PUMP, FILTER, HEATER AND AUTOMATION CONTROLS]. 2022
CALIFORNIA BUILDING CODES.
Use of Permit
Construction Details
POOL ENGINEERINGEngineer of Record 1Quantity of Detached
Spa(s)/Water
Feature(s)
0BBQ Electrical (EA)
0Number of Gas
Outlet(s)
0Mechanical Equipment
Relocation (QTY)
0Garden Wall Linear
Foootage
0Combination Retaining
Wall Linear Footage
0Total Wall Length
(Linear Footage)
RLZoning
LDRGeneral Plan Within La Quinta LimitsCity Limits TR 3448Subdivision Name
13Lot Number 2792.92Lot Size 86713, 86698, 86717Centerlines
Lot 13 MB 58/20 TR 3448Legal Description
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
INV-00004154 $14.55 Credit Card Convenience Fee $14.55
$124.49 Swimming Pool / Spa PC $124.49
$2.00 Building Standards Administration $2.00
$228.84 Detached Spa / Water Feature $228.84
$8.00 Technology Enhancement Fee $8.00
$228.84 Swimming Pool / Spa $228.84
$12.00 Digital Archiving and Records Management Fee - OTC $12.00
$618.72 $618.72 Total for Invoice INV-00004154
INV-00012368 $45.75 Building Staff Time $45.75
$45.75 $45.75 Total for Invoice INV-00012368
Grand Total for Permit $664.47 $664.47
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Revisions v.1 01/28/2025 0:00 01/30/2025 8:46
Revision Submittal v.1 Receive Submittal 01/28/2025 0:00 01/30/2025 8:46
Application Completeness Check v.1 02/01/2024 8:28 02/01/2024 8:28
Submittal Document Verification v.1 Generic Action 02/01/2024 8:28
Plan Check v.1 02/01/2024 0:00 02/01/2024 14:06
Building Review (1 Day) v.1 Receive Submittal 02/01/2024 0:00 02/01/2024 14:06
Printed: 2/13/25 10:16 am Page 2 of 3
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0023
49723 AVENIDA MONTERO
BUILDING PERMIT
Permit Issuance v.1 02/01/2024 14:10 02/01/2024 16:08
Verify Contractor info & Conditions have been met v.1 Generic Action 02/01/2024 14:10
Verify & Invoice Fees v.1 Generic Action 02/01/2024 14:10
Verify Fee Payment & Issue Permit v.1 Generic Action 02/01/2024 16:08
Print, Attach, and Email Building Permit v.1 Create Report 02/01/2024 16:08 02/01/2024 16:08
Pool Permit Inspection v.1 02/14/2024 0:00
Pre-Gunite v.1 Inspection 02/14/2024 0:00 02/15/2024 12:12
Pre-Gunite v.2 Inspection 02/15/2024 0:00 02/20/2024 10:52
Underground Plumbing v.1 Inspection
Underground Electrical v.1 Inspection
Underground Gas v.1 Inspection
Deck Bond v.1 Inspection 03/08/2024 0:00 03/11/2024 9:38
Pre-Plaster v.1 Inspection 01/09/2025 0:00 01/10/2025 14:22
Footing v.1 Inspection
Bond Beam v.1 Inspection
Inspections - Final v.1 01/22/2025 0:00 02/05/2025 14:44
Final Pool v.1 Inspection 01/22/2025 0:00 01/24/2025 10:47
Final Pool v.2 Inspection 02/04/2025 0:00 02/05/2025 12:18
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 2/13/25 10:16 am Page 3 of 3
Jimenez 79-735 Oxford Dr,
Indio Ca, 92203
Special. 760-250-0884
I ecslapeo le c.com
Inspections
DAILY REPORT OF INSPECTION
Building Permit No.: Date of Inspection: 2-7µ24
Project Name: Pool remodci Job No.: 1694-24
Prajeck Address: 49723 Avenida hunters La Quinta Ca
Architect: Structural Engineer;
General. Contractor : Sub Contractor: Cenda Steel
'TYPE OF INSPECTION: Concrele Masonry Steel Epoxy others
Welder, Welding Operators & Certification Numbers:
Description of Work Inspected:
Epoxy 146 # 3 dowels for new Spa, tanning bench, and dse pool bottom, tie In to existing concrete
Hole 112 4"
All hales were blown and brush dean
Epoxy , Simpson set XP exp 5-26-25
Epoxy application as per manufacture recommendation
Satisfactory
hereby certify that 1 have "-peeicd all of the above reported work, unim urthet'wise h[}Ltit, and to Lhe bmL of my ability l have f-umd this work
to vornply wok the approved plans, specifications & applicable building laws. Fines rgmtl imed at pr«jeCt completion.
Inspector's Name Will Jimenez Inspector's Signature
Certification No, 5496154 ICC
All insgecticros based on a minlmum of $ hours;
aver 4 hours will b".. 8 ]'Lours minimum Contractor's Representative_
14' 3"5'9' 10"22'4'EXISTING POOL
-3'.6"
-5'
-10"
EXISTING
DEPTH -7'
EXISTING BLOCK WALL +60"
EXISTING RESIDENCE
NEW SHELF ADDITIONNEW POOL STEPS
NEW SPA +0
EXISTING EQUIPMENT
LOCATION TO REMAIN
7'7'
Scale: 1/8" = 1 ft
TILE / TBS
TILE / TBS
MINI PEBBLE TBS
SAME
CONCRETE
1 SPA LIGHT
1POOL LIGHT
400K MT
420 SQ
3HP VSF. SPA PUMP
+ 0"
8 RANDOM
28' Inside
49 SQ FT
7' X 7'
NA
3'-6" - 5'
91'
383SQ FT
32' X 14'
SHEET A-1
HOPE RADER
49-723 AVENIDA MONTERO
LAQUINTA, CA
GATE CODE:#7295
USE WASHINGTON
01/20/2024
SPA ADDITION / POOL
DATE:
PROJECT:
RESIDENCE:
SPILLWAY:
WATERLINE:
INTERIOR:
DECKING:
SPA COPING:
POOL COPING:
FINSHES
SPA LIGHT:
POOL LIGHT:
HEATER:
FILTER:
PUMP:
EQUIPMENT
SPA
JETS:
SURFACE AREA:
SPA SIZE:
PERIMETER:
SPA SPECS
RAISED BOND BEAM:
DEPTH:
PERIMETER:
SURFACE AREA:
POOL
POOL SPECS
LIC # C-53, 802919
P.O BOX 10641
PALM DESERT, CA 92255
SCALE: 1/8" = 1"
CONCRETE
PLEASE NOTE:
A SECOND FORM OF DROWNING PREVENTION IS A
POOL GUARD FLOATING ALARM WITH ASTM SAFETY
RATING WILL BE USED
PLEASE NOTE:
A SECOND FORM OF DROWNING PREVENTION IS A
POOL GUARD FLOATING ALARM WITH ASTM SAFETY
RATING WILL BE USED
PROJECT NOTES:
POOL EQUIPMENT SHALL BE SEIZMICALLY ANCHORED
POOL EQUIPMENT SHALL HAVE 36" WORKING CLEARANCES
POOL EQUIPMENT WILL BE 3' FROM PROPERTYLINE
LIGHTS ARE GLOBRITE LED AND WILL HAVE WATERBOND AT SKIMMER FOR ACCESS
THE POOL WILL HAVE A #8AWG COPPER BONDING WIRE CLAMPED IN 4 PLACES WITH
APPROVED CLA,PS 24" OF THE POOL BOND BEAM RUNNUNG CONTINUOUSLY AROUND
PERIMETER.
DOOR ALARMS WILL BE PRESENT ON ALL DOORS LEADING TO POOL AREA
FLOATING SAFETY ALARMS WILL BE USED IN POOL AND SPA
GATES WILL SWING AWAY FROM POOL AREA WITH SELF CLOSING LATCHES ABOVE 54"
MAIN DRAIN COVERS WILL BE SPLIT A MINIMUM OF 36: SEPERATION
PROJECT NOTES:
POOL EQUIPMENT SHALL BE SEIZMICALLY ANCHORED
POOL EQUIPMENT SHALL HAVE 36" WORKING CLEARANCES
POOL EQUIPMENT WILL BE 3' FROM PROPERTYLINE
LIGHTS ARE GLOBRITE LED AND WILL HAVE WATERBOND AT SKIMMER FOR ACCESS
THE POOL WILL HAVE A #8AWG COPPER BONDING WIRE CLAMPED IN 4 PLACES WITH
APPROVED CLA,PS 24" OF THE POOL BOND BEAM RUNNUNG CONTINUOUSLY AROUND
PERIMETER.
DOOR ALARMS WILL BE PRESENT ON ALL DOORS LEADING TO POOL AREA
FLOATING SAFETY ALARMS WILL BE USED IN POOL AND SPA
GATES WILL SWING AWAY FROM POOL AREA WITH SELF CLOSING LATCHES ABOVE 54"
MAIN DRAIN COVERS WILL BE SPLIT A MINIMUM OF 36: SEPERATION
GATE +60" MINMUM AND WILL OPEN
AWAY FROM THE POOL WHILE BEING
SELF CLOSING WITH AN ADDITIONAL
LATCH +54"
GATE +60" MINMUM AND WILL OPEN
AWAY FROM THE POOL WHILE BEING
SELF CLOSING WITH AN ADDITIONAL
LATCH +54"
2022 California Building code (CBC)
2022 California Residential Code (CRC) 2
2022 California Electrical Code (CEC) 2
2022 California Mechanical Code (CMC) 2
2022 California Plumbing Code (CPC) 2
2022 California Energy Code (CEC) 2
2022 California Green Building Standards Code (CGBC)
2022 California Building code (CBC)
2022 California Residential Code (CRC) 2
2022 California Electrical Code (CEC) 2
2022 California Mechanical Code (CMC) 2
2022 California Plumbing Code (CPC) 2
2022 California Energy Code (CEC) 2
2022 California Green Building Standards Code (CGBC)
EXISTING RESIDENCE
Digitally signed by Matthew Thompson on 01/26/2024 - 1706256000 - 24-00662-dg
640-A
640-D
640-A
Digitally signed by Matthew Thompson on 01/26/2024 - 1706256000 - 24-00662-dg
Digitally signed by Matthew Thompson on 01/26/2024 - 1706256000 - 24-00662-dg
14' 3"5'9' 10"22'
4'EXISTING POOL-3'.6"-5'-10"EXISTINGDEPTH -7'EXISTING BLOCK WALL +60"EXISTING RESIDENCENEW SHELF ADDITIONNEW POOL STEPSNEW SPA +0EXISTING EQUIPMENTLOCATION TO REMAIN7'7'32'14'34' 10"9'Scale: 1/8" = 1 ftTILE / TBSTILE / TBSMINI PEBBLE TBSSAMECONCRETE1 SPA LIGHT1POOL LIGHT400K MT420 SQ3HP VSF. SPA PUMP+ 0"8 RANDOM28' Inside49 SQ FT7' X 7'NA3'-6" - 5'91'383SQ FT32' X 14'SHEET A-1HOPE RADER49-723 AVENIDA MONTEROLAQUINTA, CAGATE CODE:#7295USE WASHINGTON01/20/2024SPA ADDITION / POOLDATE:PROJECT:RESIDENCE:SPILLWAY:WATERLINE:INTERIOR:DECKING:SPA COPING:POOL COPING:FINSHESSPA LIGHT:POOL LIGHT:HEATER:FILTER:PUMP:EQUIPMENTSPA RAISED:JETS:SURFACE AREA:SPA SIZE:PERIMETER:SPA SPECSRAISED BOND BEAM:DEPTH:PERIMETER:SURFACE AREA:POOL SIZE:POOL SPECSLIC # C-53, 802919P.O BOX 10641PALM DESERT, CA 92255SCALE: 1/8" = 1"CONCRETEPLEASE NOTE:A SECOND FORM OF DROWNING PREVENTION IS APOOL GUARD FLOATING ALARM WITH ASTM SAFETYRATING WILL BE USEDPLEASE NOTE:A SECOND FORM OF DROWNING PREVENTION IS APOOL GUARD FLOATING ALARM WITH ASTM SAFETYRATING WILL BE USEDPROJECT NOTES:PROJECT NOTES:POOL EQUIPMENT SHALL BE SEIZMICALLY ANCHOREDPOOL EQUIPMENT SHALL BE SEIZMICALLY ANCHOREDPOOL EQUIPMENT SHALL HAVE 36" WORKING CLEARANCESPOOL EQUIPMENT SHALL HAVE 36" WORKING CLEARANCESPOOL EQUIPMENT WILL BE 3' FROM PROPERTYLINEPOOL EQUIPMENT WILL BE 3' FROM PROPERTYLINELIGHTS ARE GLOBRITE LED AND WILL HAVE WATERBOND AT SKIMMER FOR ACCESSLIGHTS ARE GLOBRITE LED AND WILL HAVE WATERBOND AT SKIMMER FOR ACCESSTHE POOL WILL HAVE A #8AWG COPPER BONDING WIRE CLAMPED IN 4 PLACES WITHTHE POOL WILL HAVE A #8AWG COPPER BONDING WIRE CLAMPED IN 4 PLACES WITHAPPROVED CLA,PS 24" OF THE POOL BOND BEAM RUNNUNG CONTINUOUSLY AROUNDAPPROVED CLA,PS 24" OF THE POOL BOND BEAM RUNNUNG CONTINUOUSLY AROUNDPERIMETER.PERIMETER.DOOR ALARMS WILL BE PRESENT ON ALL DOORS LEADING TO POOL AREADOOR ALARMS WILL BE PRESENT ON ALL DOORS LEADING TO POOL AREAFLOATING SAFETY ALARMS WILL BE USED IN POOL AND SPAFLOATING SAFETY ALARMS WILL BE USED IN POOL AND SPAGATES WILL SWING AWAY FROM POOL AREA WITH SELF CLOSING LATCHES ABOVE 54"GATES WILL SWING AWAY FROM POOL AREA WITH SELF CLOSING LATCHES ABOVE 54"MAIN DRAIN COVERS WILL BE SPLIT A MINIMUM OF 36: SEPERATIONMAIN DRAIN COVERS WILL BE SPLIT A MINIMUM OF 36: SEPERATIONGATE +60" MINMUM AND WILL OPENAWAY FROM THE POOL WHILE BEINGSELF CLOSING WITH AN ADDITIONALLATCH +54"GATE +60" MINMUM AND WILL OPENAWAY FROM THE POOL WHILE BEINGSELF CLOSING WITH AN ADDITIONALLATCH +54"2022 California Building code (CBC)2022 California Residential Code (CRC) 22022 California Electrical Code (CEC) 22022 California Mechanical Code (CMC) 22022 California Plumbing Code (CPC) 22022 California Energy Code (CEC) 22022 California Green Building Standards Code (CGBC)2022 California Building code (CBC)2022 California Residential Code (CRC) 22022 California Electrical Code (CEC) 22022 California Mechanical Code (CMC) 22022 California Plumbing Code (CPC) 22022 California Energy Code (CEC) 22022 California Green Building Standards Code (CGBC)EXISTING RESIDENCEN02/01/2024
14' 3"5'9' 10"22'
4'EXISTING POOL-3'.6"-5'-10"EXISTINGDEPTH -7'EXISTING BLOCK WALL +60"EXISTING RESIDENCENEW SHELF ADDITIONNEW POOL STEPSNEW SPA +0EXISTING EQUIPMENTLOCATION TO REMAIN7'7'32'14'34' 10"9'Scale: 1/8" = 1 ftTILE / TBSTILE / TBSMINI PEBBLE TBSSAMECONCRETE1 SPA LIGHT1POOL LIGHT400K MT420 SQ3HP VSF. SPA PUMP+ 0"8 RANDOM28' Inside49 SQ FT7' X 7'NA3'-6" - 5'91'383SQ FT32' X 14'SHEET A-1HOPE RADER49-723 AVENIDA MONTEROLAQUINTA, CAGATE CODE:#7295USE WASHINGTON01/20/2024SPA ADDITION / POOLDATE:PROJECT:RESIDENCE:SPILLWAY:WATERLINE:INTERIOR:DECKING:SPA COPING:POOL COPING:FINSHESSPA LIGHT:POOL LIGHT:HEATER:FILTER:PUMP:EQUIPMENTSPA RAISED:JETS:SURFACE AREA:SPA SIZE:PERIMETER:SPA SPECSRAISED BOND BEAM:DEPTH:PERIMETER:SURFACE AREA:POOL SIZE:POOL SPECSLIC # C-53, 802919P.O BOX 10641PALM DESERT, CA 92255SCALE: 1/8" = 1"CONCRETEPLEASE NOTE:A SECOND FORM OF DROWNING PREVENTION IS APOOL GUARD FLOATING ALARM WITH ASTM SAFETYRATING WILL BE USEDPLEASE NOTE:A SECOND FORM OF DROWNING PREVENTION IS APOOL GUARD FLOATING ALARM WITH ASTM SAFETYRATING WILL BE USEDPROJECT NOTES:PROJECT NOTES:POOL EQUIPMENT SHALL BE SEIZMICALLY ANCHOREDPOOL EQUIPMENT SHALL BE SEIZMICALLY ANCHOREDPOOL EQUIPMENT SHALL HAVE 36" WORKING CLEARANCESPOOL EQUIPMENT SHALL HAVE 36" WORKING CLEARANCESPOOL EQUIPMENT WILL BE 3' FROM PROPERTYLINEPOOL EQUIPMENT WILL BE 3' FROM PROPERTYLINELIGHTS ARE GLOBRITE LED AND WILL HAVE WATERBOND AT SKIMMER FOR ACCESSLIGHTS ARE GLOBRITE LED AND WILL HAVE WATERBOND AT SKIMMER FOR ACCESSTHE POOL WILL HAVE A #8AWG COPPER BONDING WIRE CLAMPED IN 4 PLACES WITHTHE POOL WILL HAVE A #8AWG COPPER BONDING WIRE CLAMPED IN 4 PLACES WITHAPPROVED CLA,PS 24" OF THE POOL BOND BEAM RUNNUNG CONTINUOUSLY AROUNDAPPROVED CLA,PS 24" OF THE POOL BOND BEAM RUNNUNG CONTINUOUSLY AROUNDPERIMETER.PERIMETER.DOOR ALARMS WILL BE PRESENT ON ALL DOORS LEADING TO POOL AREADOOR ALARMS WILL BE PRESENT ON ALL DOORS LEADING TO POOL AREAFLOATING SAFETY ALARMS WILL BE USED IN POOL AND SPAFLOATING SAFETY ALARMS WILL BE USED IN POOL AND SPAGATES WILL SWING AWAY FROM POOL AREA WITH SELF CLOSING LATCHES ABOVE 54"GATES WILL SWING AWAY FROM POOL AREA WITH SELF CLOSING LATCHES ABOVE 54"MAIN DRAIN COVERS WILL BE SPLIT A MINIMUM OF 36: SEPERATIONMAIN DRAIN COVERS WILL BE SPLIT A MINIMUM OF 36: SEPERATIONGATE +60" MINMUM AND WILL OPENAWAY FROM THE POOL WHILE BEINGSELF CLOSING WITH AN ADDITIONALLATCH +54"GATE +60" MINMUM AND WILL OPENAWAY FROM THE POOL WHILE BEINGSELF CLOSING WITH AN ADDITIONALLATCH +54"2022 California Building code (CBC)2022 California Residential Code (CRC) 22022 California Electrical Code (CEC) 22022 California Mechanical Code (CMC) 22022 California Plumbing Code (CPC) 22022 California Energy Code (CEC) 22022 California Green Building Standards Code (CGBC)2022 California Building code (CBC)2022 California Residential Code (CRC) 22022 California Electrical Code (CEC) 22022 California Mechanical Code (CMC) 22022 California Plumbing Code (CPC) 22022 California Energy Code (CEC) 22022 California Green Building Standards Code (CGBC)EXISTING RESIDENCEN01/30/2025