BWFE2024-0047 - CalcsORCO WALL SYSTEM STRUCTURAL CALCULATIONS PREPARED FOR BEAZER HOMES CANTERA A T CORAL MOUNTAIN TRACT No. 31249 CITY OF LA Q UI N TA, CALIFORNIA ENGINEERING STAMP APPROVAL IS CONDHIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. �1 `iER D UG { Fy �(r r' c NO. 83660 * EXP. 031JI12025 s�q r C / V ' ,,, OF CAS% +' PREPARED BY ORCO BLOCK & HARDSCAPE 11100 BEACH BLVD STANTON, CA. 90680 TEL. (714) 527-2239 FAX. (774) 897-1904 ORCO WALL SYSTEM FORCES PER 2022 CBC CHAPTER /6 /-A �, TA- aA WIND FORCES TO WALLS PER ASCE 7 SECTION 29.3 CHECK WIND FORCE CALCULATION FOR 3 SECOND GUST SPEED EXPOSURE C CONDITION USING ASCE 7 CHAPTER 29 WIND LOADS 8 USING SECTION 29.3.1 TO FIND THE 3 SEC. VELOCITY PRESSURE OH. QH= 0.00256 KZ KZT KD KE V2... (EQ. 26.10-0, WHERE: KZ = 0.85 FOR EXP C (TABLE 26.10-1), KZT = 1.0 DEFAULT PER SEC. 26.8.2, KD = 0.85 (TABLE 26.6-1) 8 KE = 1.0 PER SECTION 26.9 THEREFORE: 0, = (0. 00256) (0.85) 0.0) (0.85) 0. 0) V" DESIGN WIND FORCE, FH= OH GCFAS..(EQ. 29.3-1), WHERE: G= 0.85 FROM SECTION 26.1/.1, AND CF = 1.40 PER FIGURE 29.3-1 USING AVERAGE ASPECT RATIO (WALL LENGTH TO HEIGHT) OF 2. NOTE: CF RANGES FROM 1.48 FOR A 5' WIDE RETURN WALL TO l.3 FOR A 60' PANEL. PROJEC T S/ TE WIND ZONE: V UL T = // 0 MPH EXPOSURE C THEREFORE WIND FORCE =2,(,_ -7- PSF SEISMIC FORCES PER 2022 CBC (ASCE 7 SECT /5. 4.1B) PROF E S S I QN Iwo y ,ft DI) �c FOR NONBUILD/NG STRUCTURES: - FREE STANDING WALLS AND PILASTERS �. m m m - PROJECT SITE CLASS D Np, 836r50 A - FUNDAMENTAL PERIOD T GREATER THAN 0. 06 SEC k ExP 0/31,1025 CALCULATED USING EQUATION 12. 8-7 AND TABLE 12. 8-2 srs C I V I %- a�%V AF OF CA0FO PER EONS. 12.8-I AND 12.8-2, SEISMIC BASE SHEAR: V= C S W = IS DS /(R1I E)) W , WHERE I E = 1. 0 FROM TABLE 1. 5-2 8 R = 1, 25 FROM TABLE 15. 4.2 SEISMIC FORCE SDS 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.l0 1.20 /.30 /.40 1.50 V 2 [(SDS)1(R11E)1 W 0.32W 0.40W 0.48W 0.56W 0.64W 0.72W 0.80W 0.88W 0. 96W 1.04W 1.12W 1.20W PROJEC T S/ TE SEISMIC /NFORMA TION. S DS = /• O & V = A 9 W CMU WALL WEIGHTS PER SO. FT. (NW) 16,11 CMU WIDTH 6' CMU W1 JOINT REINFORCEMENT 8" CMU PILASTER LAS PILASTER PILASTER GROUTED ® 01C 48'01C 40'01C 32'01C 24101C I6'01C SOLID 32101C 24'01C 16'01C SOLID SOLID SOLID WEIGHT 45 PSF 46 PSF I 47 PSF 48 PSF 52 PSF 63 PSF 58 PSF 61 PSF 66 PSF 84 PSF /33 PSF 175 PSF THEREFORE SEISMIC FORCE IS: V = (0.9 )(SZ PSF) = V, (O PSF ORCO CMU SITE WALLS W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C CAP UNIT ORCO 6616 OR 6816 CMU �~ GROUTED ONLY @ VERT STEEL #4 DROP -IN BAR @ 16" O/C C@ CENTER OF CMU NOTE: PROVIDE #4 DOWEL & #4 DROP -IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES #6 STD JOINT REINFORCEMENT * 12" O/C FOR 6616 CMU @ 16" O/C FOR 6816 CMU NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURES, A 112 BLOCK MAY LEFT OUT @ SWALE GRADE. PROVIDE #4 DOWEL AND #4 DROP -IN BAR ON EACH SIDE OF THE 112 BLOCK DRAIN. #4 DOWEL @ 16" O/C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. ti f 2 'v 2 1 MAX. • #4 HORZ. CONT. v @ 12" O/C. M SETBACK: 8- AT LEAST THE SMALLEST OF CdNT H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #1B DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI Cal 28 DAYS 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 1. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VER7IC4L REBAR SHALL BE SOLID GROUTED. Z USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLEAND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCKSTEM MAYBE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL 15 IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20' O/C. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS, n BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNM %+c.� JEROUG � co A 2�2 a NO. 83660 * EXP. 031JI12025 P s q p C r V` N, a��\ E OF CA0 ORCO CMU SITE WALLS W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST Cad EXP C REBAR NOTE: • DO NOT RUN HORIZONTAL REINFORCEMENT THROUGH WALL RETURNS & CONTROL JOINTS. • PROVIDE DOWEL & DROP -IN BAR ACCORDING TO DETAIL AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES. O N ORCO 6616 OR 6816 CMU GROUTED ONLY @ VERT STEEL #4 - DROP -IN BAR @ 16" O/C @ CENTER OF CMU #6 STD JOINT REINFORCEMENT @ 12" O/C FOR 6616 CMU * 16" O/C FOR 6816 CMU #4 DOWEL @ 16" O/C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. SETBACK: AT LEAST THE SMALLEST OF H13 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT NOTE: DIMENSIONS ARE NOT TO SCALE. DETAIL #1A DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH, f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 1. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE IIIV. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60, PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USINGA5TM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS: 9. BLOCK STEM MAY BE WET -SET 1-112"INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20' O/C. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNM day/2��ZoZ3�� N0. 83660 D * EXP. 0JI3112025 T 5 F OF CA `�F Cantilevered Retaining Wall LICk : KW-66MBbO3. Bu ls} M23.2.14 DESCRIPTION: (01 a) Site Wall Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 0.33 ft Wall height above soil - 6.67 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water height over heel - 0.0 ft Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Project Title: Engineer: Project ID: Project Descr: Project File: beazer homes_cantera_la quinta.ec6 OFICO BLOCK COMPANY INC tcl ENERCALCI C f-98-3-2022 Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 277.3 #/ft ...Height to Top = 5.28 It ...Height to Bottom = 4.28 It Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall _ 0.0 ft - Poisson's Ratio = 0.300 oofESS10 yERDUGp w4ly u co M . m NO 83660 * EXP 03/31/2025 sglFC/V OF Opp. 1` Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LICO : KW-06016603. Bulld:29.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (01 a) Site Wall Project File: beazer homes _cantera_la quinta.ec6 (c} ENEgCALC INC 1983.2022 Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning - 1.24 Ratio < 1.5! Design Method = SD Sliding = 1.93 OK Thickness = 6.00 Global Stability - 4.92 Rebar Size = # 4 Rebar Spacing = 16.00 Total Bearing Load = 924 Ibs Rebar Placed at = Center ,V ...resultant ecc. = 14.43 in Design Data \ Eccentricity outside middle third fb/FB + fa/Fa = 0.769 Soil Pressure @ Toe 2,037 psf OK Total Force @ Section Soil Pressure @ Heel 0 psf OK Service Level Ibs = i Allowable = 2,667 psf Soil Pressure Less Than Allowable Strength Level Moment.... Actual Ibs= 280.4 ACI Factored @ Toe 2,851 psf Service Level ft-#= ACI Factored @ Heel = 0 psf Strength Level ft-#= 1,326.0 Footing Shear @ Toe = 8.1 psi OK Moment..... Allowable = 1,722.7 Footing Shear @ Heel = 2.5 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = Sliding Calcs Strength Level psi = 8.0 Lateral Sliding Force = 225.1 Ibs Shear..... Allowable psi = 80.5 less 100% Passive Force - 64.8 Ibs Anet (Masonry) in2 = 35.07 less 100% Friction Force s - 369.5 Ibs Wall Weight psf = 52.0 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' In = 2.81 ....for 1.5 Stability = 0.0 Ibs OK Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fy psi = 60,000 Solid Grouting = No Load Factors Modular Ratio 'n' = 16.11 Building Code Equiv. Solid Thick. in = 4.11 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = SD Earth, H 1.600 Concrete Data _- Wind, W 11000 f'c psi = Seismic, E 1.000 Fy psi= ASD 4ROFESS/QN A ti`w9 JERDUG0 r �c �v Darn NO 83660 EXP 03/31/2025 yE C I V P OF CAL 1Fd Cantilevered Retaining Wall LION - KW-06016003. Build:20.23.2.14 DESCRIPTION: (01 a) Site Wall Footing Data Toe Width = 1.25 ft Heel Width = 1.75 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project Title: Engineer: Project ID: Project Descr: ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC Toe Heel Factored Pressure = 2,851 Mu': Upward = 1,212 Mu': Downward = 212 Mu: Design = 1,001 OK phiMn = 2,500 2 Actual 1-Way Shear = 8.10 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 240 ft-# 240 ft-# OK ,500 ft-# 2.54 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft if one layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in eRaFe55+oHa ¢w9 Ire . m. IW DIA NO. 83660 * EXP. 03/31/2025 ,p�glFC fV%1. aR�r OF CAL IF Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File., beazer homes_cantera_la quinta.ec6 LEG# : Kw-mb16003. 8ulId:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENEACALC INC 1983.2022 DESCRIPTION: (01 a) Site Wall Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 31.0 0.44 13.7 Soil Over HL (ab. water tbl) 47.4 2.38 112.7 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.38 112.7 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = 194.1 5.78 1,122.1 ' Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 47.9 0.63 29•9 Surcharge Over Toe = Stem Weight(s) = 364.0 1.50 546.0 Earth @ Stem Transitions= Total = 225.1 O.T.M. = 1,135.8 Footing Weight = 450.0 1.50 675.0 Key Weight = Resisting/Overturning Ratio = 1.24 Vert. Component = 14.3 3.00 42.9 Vertical Loads used for Soil Pressure = 923.6 Ibs Total = 923.6 Ibs R.M.= 1,406.5 " Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.220 in The above calculation Is not valid if the lie eI soil ea ri nq pressure exceeds that at the toe because the wall would then tend to rotate into the retained soil. QROFESS/ON ��¢rti9 .1EROt1C 4 Fc w 0I m NO B3660 D * EXP 03/31/2025 Jar C, I V qYE OF CnL,404 TRENCH FOOTING OVERTURNING AND SLIDING CHECK OVERTURNING WALL DIMENSIONS HF = 7 ft Freestanding height (TF to TW) input BF = 0.5 ft Freestanding portion width input FTGp = 3.5 ft Footing depth input FTGW = 0.67 ft Footing width input c = 0.33 ft Footing cover input HE = 6.67 ft Exposed height of wall SEISMIC CS = 0.8 RESISTING MOMENT Self weight of wall WTF = 52 psf Freestanding wall weight per sq.ft. input wF = WTF (HF - c)= 346.84 plf Freestanding wall weight per ft of wall MF = wF FTGW/2 = 116.1914 ft-lb Moment due to freestanding wall self weight WTFT = 150 pcf (FTGW) = 100.5 psf Footing weight per sq.ft. wFT = WTFT FTGp = 351.75 plf Footing weight per ft of wall MFT = wFT FTGW/2 = 117.8363 ft-lb Moment due to footing self weight Self weight of soils on top of footing WTS = 115 pcf Unit weight of soil input wS/FT= WTS (FTGW BF) c = 6.45 plf Weight of soil on top of footing per ft MS = wS/FT * FTGW/2 = 2.16 ft-lb Moment due to soil self weight (on top of footing) Passive Pp = 250 psf/ft Dig = 1 ft PPP = 0.5 Pp (FTGpz - Dig): 1,708.61 lb h = 2.83 ft y= 1.19 ft MPP = Pp, y = 2,032.62 ft-lb Resisting Moment MR = MF+MFT+MPP+MS = 2,268.81 ft-lb OVERTURNING MOMENT Ultimate passive pressure (increased 1/3 for s input Depth to ignore passive input Passive resistance depth of Passive Resistance triangle or trapezoid Vert. distance of centroid of triangle/trapezoid, from bot Moment resistance (passive) - Seismic Vs = CS (wF) = 277.472 plf Seismic Load Mv, = Vs * (2/3*HE + c + F- 2296.543 ft-lb Moment MOTs = 0.7Mv, = 1,607.58 ft-lb per CBC 1807.2.3 - Active pressure EFP = 35 pcf Equivalent fluid pressure Pa = 0.5 EFP (FTGp + c)z 256.71 lb Active load G] 4 h+,1 i�ii7. �a .. •_ -� � � it t�� r�iti t�I input Mora = Pa (FTGp + c)/3 327.73 ft-lb Overturning moment due to active pressure Overall Overturning moment MOT = MOTs + MOTa = 1,935.31 ft-lb FACTOR OF SAFETY "OVERTURNING" SEISMIC FSOTs = MR / Mors = 1.17 > 1.1 OK Check SLIDING FC = 0 Soil Friciton Coefficient input SLIDING RESISTANCE Self weight of wall SRF = FC wF = 0 lb Sliding resistance due to CMU freestanding portion SRFT = FC WFT = 0 lb Sliding resistance due to Concrete footing Self weight of soil on top of footing SRS = FC WS/FT = - lb Sliding resistance due soil on top of footing Passive PPP = 1,708.61 lb Passive resistance Sliding Resistance SR = SRF + SRR + SRFT + + SRS + PPP = 1,708.61 lb SLIDING FORCES Seismic ....... 0.7 Vs 194.23 lb Active pressure P - 256.71 lb E• n, ri Pa (9 ` ti 4 r Total sliding force e+ti q ' SF = 0.7 Vs + Pa = lb FACTOR OF SAFETY "SLIDING" Seismic FSs, = SR / SF = 3.79 > 1.1 OK ORCO 12" SQ. PILASTER FOR 110 MPH 3 SEC. GUST @ EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH Pm = 2000 PSI. r ►A: CAP UNIT ORCO 12612 PILASTER CMU SOLID GROUTED. SEE DIAGRAM BELOW #4 VERT. DROP -IN BAR #4 DOWEL W/ 24' MIN. EXTENSION INTO CMU J Q ? N 'a #4 HORZ 0 9' 0/C EACH WAY GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE ILIV. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60, PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A STACK BOND PATTERN. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS 9. BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHESARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACEAND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHERE INTERSECTION BLOCK WALLS OCCUR. EOUAL ORCO 12612 PILASTER CMU 2 (SOLID GROUTS[ F v 2 1 MAX. 3'-0" SQUARE FOOTING NOTE ONLY RUN WALL FOOTING HORIZONTAL REINFORCEMENT THROUGH PILASTER FOOTING, WHEN INTERSECTING. DETAIL #2 SETBACK.• AT LEAST THE SMALLEST OF H13 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT #4 VERTICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO SC4LE ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. ¢�10 -4 ftDUGO 4z BEAZER HOMES CANTERA @ CORAL MOUNTAIN TRACT No. 31249 / g �Zo2 3 D LA QUINTA, CALIFORNIA N0. 83660 * EXP. 03/3//2025 1.6LOTE: DIMENSIONS ARE NOT TO SCALE. `�'*4 c J V ` lF OF CAL�Fq¢ Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (02) Pilaster Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 0.33 ft Wall height above soil = 7.33 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Project Title: Engineer: Project ID: Project Descr: Project File: beazerhom6s- C.antenk la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 260.1 #/ft ...Height to Top = 5.72 ft ...Height to Bottom = 4.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) r Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 QROFESS/flN. �4wo yrGRp!!g Q 0c ti� cl 4r wI �m � D A NO 83660 * EXP 03/31/2025 T4 CIV�1 lF OF c4k-'FO4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I.IC4 : KW-06016003, Biaild:20.23.2A4 DESCRIPTION: (02) Pilaster Design Summary Project File: beazer homes_cantera_la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Stem Construction Wall Stability Ratios Overturning = 1.17 Ratio < 1.5! Sliding 1.95 OK Global Stability = 3.71 Total Bearing Load = 877 Ibs Q resultant ecc. = 15.36 in Eccentricity outside middle third Soil Pressure @ Toe = 2,610 psf OK ' Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 3,653 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 8.1 psi OK Footing Shear @ Heel = 2.1 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 213.0 Ibs less 100% Passive Force - 64.8 Ibs less 100% Friction Force - 350.7 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Reber Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Masonry Data f'm Fs Solid Grouting Modular Ratio'n' Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data f'c Fy 'Bottom Stem OK ft = 0.00 Masonry ASID 12.00 # 4 16.00 Center 0.442 Ibs= 184.0 Ibs = ft-# = 950.6 ft-# = 2,146.1 psi = 1.3 psi = psi = 51.0 in2 = 139.50 psf = 43.9 in = 5.81 psi = 2,000 psi = 32,000 Yes 16.11 in= 11.63 psi = psi = ASD QROFESS/QNQ UG m � D A NO 83660 * EXP 03/31/2025 S 1r CiV i�- a��P O OF CAS-\F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (02) Pilaster Footing Data Toe Width = 1.00 ft Heel Width = 2.00 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth - 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in ORCO BLOCK COMPANY INC Footing Design Results Project File: beazar homescantera_!a qulnta.ec6 (c) ENERCALC INC 1983-2022 Toe Heel Toe: phiMn = ph'S`lambda'sgrt(fc)" Sm Heel: phiMn = ph`5`lambda`sgrt(fc)'Sm Key: No key defined 0 psf 0 ft-# 192 ft-# 192 ft-# OK ,500 ft-# 2.07 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one laver of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in QROFESSION ,SRDUG �� ua, QI SS4' m NO 83660 * EXP 03/31/2025 �4r C I V tL ¢ttio R Ox C4L %% Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LICH - KW-06016003, 131fiId'20.23- A4 DESCRIPTION: (02) Pilaster ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs It ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 31.0 0.44 182.1 6.22 13.7 1,132.4 Total 213.0 O.T.M. = 1,146.2 Resisting/Overturning Ratio = 1.17 Vertical Loads used for Soil Pressure = 876.8 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC M3.2022 ...RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 38.0 2.50 94.9 Soil Over HL (bel, water tbl) 2.50 94.9 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = 38.3 0.50 19.2 Surcharge Over Toe = Stem Weight(s) = 336.2 1.50 504.3 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = Vert. Component = 14.3 3.00 42.9 Total = 876.8 Ibs R.M.= 1,336.2 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Tol) of Wall due to settlement of soi (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Deft @ Top of Wall (approximate only) 0.308 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the tom, because the wall would then tend to rotate into the retained soil. QpOFESSlOti4 �0 'IeRDU17 Fs v it a D1A� NO- 83660 * EXP 03/31/2025 sr C f V OF cA04 ORCO CMU + T. S. FENCE W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C DESIGN CRITERIA PER THE 2022 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. vi GENERAL 1. 2. NOTES: CONCRETE BLOCK SHALL BE MANUFACTURED BYORCO ASTM C 90. NORMAL WEIGHT. CONCRETE FOR FOOTING SHALL BE I PART CEMENT TO 1-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1 1/1 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM mC 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A . U 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. c O 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOG4TED. p p m 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH N W VERTICAL CONTINUITY OF THE CELLS UNO. W ti 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID Z Z GROUTED. #4 HORZ. CONT. @ h Wp 7. TOP BOND BEAM USE TYPES MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. II (OR PENCIL RODS). a 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PART5 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT l j #4 DOWEL 0) 32" O/C FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW ti @CENTER OF CMU. WITHOUT SEGREGATION OF THE CONSTITUENTS h 9. BLOCK STEM MAY BE WET -SET 1-1/2-INTO THE FOOTING WHILE THE W 101,OF CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE U �o I� THE TRENCH TYPE FOOTING. o�p > #4 HORZ CONTT, 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL b O 2 @ 24" O/C OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. O p p 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE READY FOR fEQUAL EQUAL CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND + INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND ° THE BLOCK WALL 15 READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20' O/C. ti I CONT. 4S SHOWN oe SETBACK: v 2' 2" AT LEAST THE SMALLEST OF ;h H/3 AND 40 FT (7 FT MIN.), WHERE H = SLOPE HEIGHT ENGINEERING STAMP APPROVAL IS CONDITIONAL; NOTE: DIMENSIONS ARE NOT TO SCALE. REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DETAIL �a ,eR D UG 4c BEAZER H01" y �-a s GANTERA @ CORAL MOUNT " m TRACT No. 31249 y�t LA QUINTA, CALIFORNIA NO. 83660 * EXP. 0313112025 P2gT C , V IN, � `P F Op CA01Q ORCO CMU + T.S. FENCE W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C DESIGN CRITERIA PER THE 2022 CDC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL 1, NOTES: CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. = ti NORMAL WEIGHT. O 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS m SAND TO 3-1/1 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS j OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM O U C 150 TYPE II/V. Fc = 2500 PSI 00 OF� @� 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A O615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. g m 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH ^� W IT IS LOCATED. U ti 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH 2 VERTICAL CONTINUITY OF THE CELLS UNO. #4 HORZ. CONT. @a WQ TOP BOND BEAM 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID 5 (OR " PENCIL RODS). GROUTED. Z USE TYPES MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. • 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART W #4 DOWEL @ 32" O/C CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA @ CENTER OF CMU. GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT J FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW V j WITHOUT SEGREGATION OF THE CONSTITUENTS. b Q #4 HORZ CONT. 9. BLOCKSTEM MAYBE WET -SET 1-1/1" INTO THE FOOTING WHILE THE op > CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE b 62 @ 24" O/C OF THE TRENCH TYPE FOOTING. O O W 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL j $ OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 2 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR MAX. 1 CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. • #4 HORZ. CONTT, 12. MAXIMUM CONTROL JOINT SPACING: 20' 0/C. _ @ 10" O/C O 0 M 3" CLR. SETBACK.' AT LEAST THE SMALLEST OF ENGINEERING STAMP APPROVAL IS CONDITIONAL; 10„ H13 AND 40 FT (7 FT MIN.), REQUIRING USE OF ORCO MANUFACTURED CMU ON WHERE H = SLOPE HEIGHT ALL ORCO WALL SYSTEM DESIGNS. NOTE: DIMENSIONS ARE NOT TO SCALE. � 4 [ �.1pRDUG BEAZER HOAfeS, DETAIL #3B cANTER4 �a CORAL MOUNTAIN " Q /�9/Zozs a m y A TRACT No. 31249 D N0. 83660 LA QUINTA, CALIFORNIA * EXP. 0313112025 s yr C 1 V ' ❑4��a F OF CA`�F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera—la quinta.ec6 LICH : Kw-ceoiwm. Build:20.23.2.14 0406 OLOCK COMPANY INC (c) ENERCALG INC 1983.2022 DESCRIPTION: (03) View fence Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data I Retained Height = 0.33 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 5.17 ft Equivalent Fluid Pressure Method Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft + Soil Density, Heel = 115.00 pcf i Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load Surcharge Over Heel — 0.0 psf Lateral Load = 0.0 #/ft Adjacent Footing Load = 0.0 Ibs Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding & Overturning Load Type = Wind (W) Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem (Strength Level) Footing Type Spread Footing Base Above/Below Soil = 0.0 ft Axial Dead Load = 0.0 Ibs Wind on Exposed Stem = 26.7 psf at Back of Wall Axial Live Load = 0.0lbs (Strength Level) Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Qa0FES3/Oy 0 q) STI m D N0. 83660 . * EXP. 03/31/2025 s�qr C I'V `� Fa~P Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2 14 DESCRIPTION: (03) View fence Design Summary Wall Stability Ratios Overturning = 1.97 OK Sliding = 2.68 OK Global Stability 4.52 Total Bearing Load = 600 Ibs ...resultant ecc. = 6.29 in Eccentricity outside middle third Soil Pressure @ Toe = 698 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 977 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 3.2 psi OK Footing Shear @ Heel = 1.4 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 113.7 Ibs less 100% Passive Force - 64.8 Ibs less 100% Friction Force = - 239.8 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Project Flle: hearer homes cantera_la qulnta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Stem Construction Design Height Above Ftg ft= Wall Material Above "Ht" _ Design Method = Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa - Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# _ Strength Level ft-# _ Moment..... Allowable ft-# _ Shear..... Actual Service Level psi = Strength Level psi = Shear..... Allowable = Anet (Masonry) in2 = Wall Weight psf = Rebar Depth 'd' in = 2nd Bottom _ Stem OK 3.50 0.00 Fence Masonry ASD ASD 8.00 # 4 32.00 Center 0.339 32.0 84.7 31.9 241.4 710.4 3.6 51.6 23.77 58.0 3.81 Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = No Load Factors Modular Ratio'n' = 16.11 Building Code Equiv. Solid Thick. = 4.48 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi= Seismic, E 1.000 Fy psi= Q�ypFE55lary4 geRDOGO 4 ��4�b �C m m.. �W a - NO 83660 EXP. 03/31/2025 sr CfvtG a$ 4rR �� CA41F6P Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIDO: KW-06016003, Bultd:20.23.2.14 DESCRIPTION: (03) View fence Footing Data Toe Width = 0.75 ft Heel Width 1.42 Total Footing Width s 2.17 Footing Thickness = 12.00 in Key Width - 0.00 in Key Depth 0.00 in Key Distance from Toe - 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1963--2622 Toe Heel Factored Pressure = 977 Mu': Upward = 234 Mu': Downward = 92 Mu: Design = 142 OK phiMn = 2,500 2 Actual 1-Way Shear = 3.23 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceotable Sizes & Soacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 2 ft-# 109 ft-# 107 ft-# OK ,500 ft-# 1.44 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.56 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal tsars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in egoFESS10V4 ERDUG w� M �. 1 0 NO. 83660 D A * EXP 03/31/2025 .P�qT C , V � L F Op CALM Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LJCP : KW-06016003. Build:20.23.2.14 DESCRIPTION: (03) View fence ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load Q Stem Above Soil = 31.0 0.44 82.8 3.91 Total 113.7 O.T.M. = Resisting/Overturning Ratio = 1.97 Vertical Loads used for Soil Pressure = 599.6 Ibs Project File: beazer homes_cantera_la quint (c) ENERCALC INC 1983-2022 ...RESISTING...., Force Distance Moment Ibs ft ft-# 13.7 Soil Over HL (ab. water tbl) 28.5 1.79 51.0 Soil Over HL (bel. water tbl) 1.79 51.0 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = 323.9 Soil Over Toe = 28.8 0.38 10.8 Surcharge Over Toe = Stem Weight(s) = 203.0 1.08 219.9 Earth @ Stem Transitions = 337.7 Footing Weight = 325.1 1.08 352.2 Key Weight = Vert. Component = 14.3 2.17 31.0 Total = 599.6 Ibs R.M.= 664.9 " Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl Q Top of Wall (approximate only) 0.082 in The above calculation is not valid If the heel soil bearing ressure extends that of the Ioa because the wall would then tend to rotate into the retained soil. QRQFESS/ON4 le ygRDtJr;O ��eFc w � m Fi1 m NO 83660 E%P 03/31/2025 4r C/V 1\-t- F OF C A0F TRENCH FOOTING OVERTURNING AND SLIDING CHECK (view wall) OVERTURNING WALL DIMENSIONS HF = 5.5 ft BF = 0.67 ft FTGp = 3 ft FTGW = 0.83 ft c = 0.33 ft HE = 5.17 ft WL = 26.7 psf RESISTING MOMENT Self weight of wall WTF = 46 psf WF = WTF (HF - c)= 237.82 plf MF = wF FTGW/2 = 98.6953 ft-lb WTFT = 150 pcf (FTGW) = 124.5 psf WFT = WTFT FTGp = 373.5 plf MFT = WFT FTGW/2 = 155.0025 ft-lb Self weight of soils on top of footing WTS = 115 pcf WS/FT= WTS (FTGW-BF) c = 6.07 plf MS = WS/FT * FTGW/2 = 2.52 ft-lb Passive Pp = 250 psf/ft Dig = 1 ft PPP = 0.5 Pp (FTGp - Di'2)= 1,261.11 lb h = 2.33 ft y= 1.01 ft MPP = PPP y = 1,273.60 ft-lb Resisting Moment MR = MF+MFT+MPP+MS = 1,529.82 ft-lb OVERTURNING MOMENT Freestanding height (TF to TW) input Freestanding portion width input Footing depth input Footing width input Footing cover input Exposed height of wall Freestanding wall weight per sq.ft. input Freestanding wall weight per ft of wall Moment due to freestanding wall self weight Footing weight per sq.ft. Footing weight per ft of wall Moment due to footing self weight Unit weight of soil input Weight of soil on top of footing per ft Moment due to soil self weight (on top of footing) Ultimate passive pressure (increased 1/3 for s input Depth to ignore passive input Passive resistance depth of Passive Resistance triangle or trapezoid Vert. distance of centroid of triangle/trapezoid, from bot Moment resistance (passive) - Wind W = WL * HE = 138.039 plf Wind Load MW = WL * (0.55*HE + c + 852.1838 ft-lb Moment MOTW = 0.6MW = 511.31 ft-lb - Active pressure EFP = 35 pcf Equivalent fluid pressure Pa = 0.5 EFP (FTGp + c)Z 194.06 lb Active load input Mora = Pa (FTGp + c)/3 215.40 ft-lb Overturning moment due to active pressure Overall Overturning moment MOT = MOTw + MOTa = 726.71 ft-lb FACTOR OF SAFETY "OVERTURNING" SEISMIC FSOT, = MR / MOTs = 2.11 > 1.1 OK Check SLIDING FC = 0 Soil Friciton Coefficient input SLIDING RESISTANCE SRF = FC wF = 0 lb Sliding resistance due to CMU freestanding portion SRFT = FC WFT = 0 lb Sliding resistance due to Concrete footing Self weight of soil on top of footing SRS = FC wS/FT = lb Sliding resistance due soil on top of footing Passive PPP = 1,261.11 lb Passive resistance Sliding Resistance SR = SRF + SRR + SRFT + + SRS + PPP = 1,261.11 lb SLIDING FORCES Seismic 0.7 Vs = 96.63 lb Active pressure Pa = 194.05 Ibwt'w,� i Total sliding force SF = 0.7Vs+Pa= �lb ati "SLIDING" 4' FACTOR OF SAFETY Seismic FSSL, = SR / SF = 4.34 > 1.1 OK ORCO 6' HIGH WALL W/ RETAINING & SPREAD FOOTING FOR 110 MPH WIND 3 SEC. GUST @ EXP C SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRYSTEM. GAP UNIT ORCO 6616 CMU GROUTED ONLY @ VERT STEEL #4 DROP -IN BAR @32" O/C. PROVIDE 24" LAP INTO 8" CMU. #6 STD JOINT c REINFORCEMENT b @ 12" O/C NOTE: PROVIDE #4 DOWEL & #4 DROP -IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND 0 WALL HEIGHT CHANGES LEVEL BACKFILL COMPACTED #4 HORZ. CONT. TO MIN. 90% COMPACTION @ 24" o/C PER ASTM 1557-D Z O —1 FCLR. ' r i-""--1 I I— FF l3 D' DOWEL CK 4" DIA. SOR 35 PERF PIPE b0 O F W/1FT WIDE OF}" GRAVEL WRAPPED W/ FI MIRA14ON FILTER b FABRIC 70 WITHIN 1 FT OF „ FG - SLOPE TO DRAIN. x;l _ WATERPROOF BACKSIDE _-_ 1 OF RETAINING WALL. 2" CLR. fE'BAR 7TO DAYLIGHT #4 HORZ. CONE. 0 12" O/CAS SHOWN 6' NOTE: DIMENSIONS ARE NOT TO SCALE. 'A' 'B' 'C' 'D' DOWEL IF BAR 2'-0" 2'-6" N/A #4@32" 0/C 33" #4@32" O/C 18" 8" J 6" 3'-0" 2'-9" N/A #4@16" 0/C 45" #4@16" 0/C 21" 8.-16" 4'-0" 3'-0" 4" #4@16" O/C 57" #4@l6" 0/C 24" 8" J 8" 5'-0" 3'-6" 7" #408" O/C 69" #4@8" O/C 30" 8"� 8" DESIGN CRITERIA PER THE 2022 CDC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3, ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE 11/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH TT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. Z USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20' O/C. DETAIL #4 ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. �1 BE.42ER HOMES ` CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, G4LIFORNI4 //4.c4vr�RDi1G +� �,c NO. 63660 * EXP. 03/3l/2025 O F OF CA��F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall UGN : KW-M160a3, Build:20.23.2.14 DESCRIPTION: (04a) 2' ret with top out Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height Wall height above soil = Slope Behind Wall = Height of Soil over Toe = Water height over heel = Surcharge Loads Project File: beazer homes_cantera_la quinta.ec6 1 -oRCO BLOCK compmy INC (c) ENERCALC INC 1983-2022 1 Soil Data r 2.00 ft Allow Soil Bearing = 2,666.6 psf 6.33 ft Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft 0.00 6.00 in = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf ,- FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 6.72 ft ...Height to Bottom = 5.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil = -1.5 ft at Back of Wall Poisson's Ratio - 0.300 ea0fE5810,V 41��° 3ER❑t1c F?. c� r�i1 m nIA NO 83660 * EXP 03/31/2025 V F OF CA`\FD Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LICK ' KW-06016003, Bui[d:20.232.14 ORCO BLOCK COMPANY INC (c) ENEFIGALC INC 1983-2022 DESCRIPTION: (04a) 2' ret with top out Design Summary Stem Construction end Bottom Stem OK Stem OK Design Height Above Ftg ft= 2.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.53 OK Design Method = ASD ASD Sliding = 2.09 OK Thickness = 6.00 8.00 Global Stability = 3.78 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 32.00 Total Bearing Load = 1,176 Ibs Rebar Placed at = Center Edge ...resultant ecc. = 10.02 in Design Data Eccentricity outside middle third fb/FB + fa/Fa = 0.846 0.703 Soil Pressure @ Toe = 1,891 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 104.2 174.2 Allowable = 2,667 psf Strength Level Ibs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 2,647 psf Service Level ft-# = 439.9 694.9 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 7.7 psi OK Moment..... Allowable ft-# = 518.6 987.8 Footing Shear @ Heel = 5.0 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 1.9 Sliding Calcs Strength Level psi = Lateral Sliding Force = 274.8 Ibs Shear..... Allowable PSI = 52.5 52.0 less 100% Passive Force 104.2 Ibs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force - 470.4 Ibs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' In = 2.81 5.25 ....for 1.5 Stability = 0.0 Ibs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ratio'n' = 16.11 16.11 Building Code Equiv. Solid Thick. in = 3.39 7.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi= Seismic, E 1.000 Fy psi = pj,pFE55/qN4 ¢�4 dEV1.QUG F rL ri1 m w � m NO 83660 D * EXP 03/31/2025 srgr H IV o' ¢ 1 v F OF C OL0 t Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIGN : KW-06016003, f3ui[d:20.23.?.1 DESCRIPTION: (04a) 2' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 2.00 Total Footing Width = 2.50 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la qulnta.ec6 (c) ENERCALC 1NC 1§83-2022 Toe Heel Factored Pressure = 2,647 Mu': Upward = 287 Mu': Downward = 52 Mu: Design = 235 OK phiMn = 2,500 2 Actual 1-Way Shear = 7.68 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Soacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 507 ft-# 507 ft-# OK ,500 ft-# 5.01 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.65 in2 Min footing T&S reinf Area per foot 0.26 in2 ift It one laver of horizontal bars: If two layers of horizontal bars- #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in QpOFESSION y�v w� dim NO. 83660 * EXP 03/31/2025 Sr C 1 V 4TE OF GA��F�¢ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LICK: Kw-06016603, Bulld:20.23.2.14 DESCRIPTION: (04a) 2' ret with top out ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 157.5 1.00 13.2 0.29 104.2 7.22 Total 274.8 O.T.M. = Resisting/OverturnIng Ratio = 1.53 Vertical Loads used for Soil Pressure = 1,175.9 Ibs Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 .....RESISTING ..... Force Distance Moment Ibs ft ft-# 157.5 Soil Over HL (ab. water tbl) 306.7 1.83 562.2 Soil Over HL (bel. water tbl) 1.83 562.2 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = 3.8 Axial Dead Load on Stem = 752.4 Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 465.5 0.78 363.1 Earth @ Stem Transitions= 913.7 Footing Weight = 375.0 1.25 468.8 Key Weight = Vert. Component Total = 1,175.9 Ibs R.M.= 1,401.3 ` Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.292 in The above calculation is not valid if I I i e heel soli bea ri no pMsure exceeds that of the toe because the wall would then tend to rotate into the retained soil. QRpFE55/ONE y � NO 83660 D * EXP 03/31/2025 C V OF C1,0 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (04b) 3' ret with top out Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height Wall height above soil - Slope Behind Wall - Height of Soil over Toe - Water height over heel = ORCO BLOCK COMPANY INC Soil Data 3.00 ft Allow Soil Bearing = 2,666.6 psf 6.33 ft Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft 0.00 6.00 in = 0.0 ft Passive Pressure 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure - 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 7.72 ft ...Height to Bottom = 6.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: Beazer homes ,cantera_ la qu1nta.ec6 (c) ENERCALC INC 1983-2022 Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil = -1.5 ft at Back of Wall Poisson's Ratio = 0.300 QgOFESS/ON UG wf� m m NO 83660 * EXP. 03/31/2025 s� CfV`L 9rF Op G A411 p4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC9 , KW-06016003. BOU20,23 2.14 DESCRIPTION: (04b) 3' ret with top out Design Summary Wall Stability Ratios Overturning - 1.64 OK Sliding = 1.64 OK Global Stability 3.26 Total Bearing Load = 1,537 Ibs ...resultant ecc. = 10.17 in Eccentricity outside middle third Soil Pressure @ Toe = 1,942 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,718 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 8.4 psi OK Footing Shear @ Heel = 6.6 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 439.2 Ibs less 100% Passive Force 104.2 Ibs less 100% Friction Force = - 614.8 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Project Fite: beazer homes_cantera_la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment ..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 f'c Seismic, E 1.000 Fy 2nd Bottom Stem OK Stem OK ft = 3.00 0.00 = Masonry Masonry = ASD ASD = 6.00 8.00 _ # 4 # 4 = 32.00 16.00 Center Edge 0.848 0.489 Ibs = 104.2 274.8 Ibs = ft-# = 439.9 945.5 ft-# _ ft-# = 518.6 1,931.1 psi = 5.9 3.0 psi = psi = 52.5 52.3 in2 = 17.53 91.50 psf = 47.0 84.0 In = 2.81 5.25 psi = 2,000 2,000 psi = 32,000 32,000 = No Yes = 16.11 16.11 In = 3.39 7.63 psi = psi ASD m pRo�essraN y; y c �N �2 . Stl '49Rr]Ut1 Center Edge 0.848 0.489 Ibs = 104.2 274.8 Ibs = ft-# = 439.9 945.5 ft-# _ ft-# = 518.6 1,931.1 psi = 5.9 3.0 psi = psi = 52.5 52.3 in2 = 17.53 91.50 psf = 47.0 84.0 In = 2.81 5.25 psi = 2,000 2,000 psi = 32,000 32,000 = No Yes = 16.11 16.11 In = 3.39 7.63 psi = psi ASD m pRo�essraN y; y c �N �2 . Stl '49Rr]Ut1 psi = psi ASD m pRo�essraN y; y c �N �2 . Stl '49Rr]Ut1 ti ti Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall _ Project File: beazer homes_cantera_la quinta.ec6 LIC# : KW--06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (04b) 3' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 2.25 Total Footing Width = 2.75 Footing Thickness = 12.00 in Key Width — 0.00 in Key Depth = 0.00 in Key Distance from Toe — 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Heel Factored Pressure = 2,718 Mu': Upward = 304 Mu': Downward = 52 Mu: Design = 252 OK phiMn = 2,500 2 Actual 1-Way Shear = 8.40 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Accerrtable Sizes & Soacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 21 ft-# 901 ft-# 881 ft-# OK .500 ft-# 6.60 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.71 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one laver of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in �RpFESS�oN Oka �rGftPtlG � �, 4� trt m M DID N0. 83660 * EXP. 03/31/2025 C i V �w rF op cA`'Fo4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2 14 ORCO BLOCK COMPANY INC DESCRIPTION: (04b) 3' ret with top out Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pros (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 280.0 1.33 373.3 55.1 0.66 36.3 104.2 8.22 856.6 Total = 439.2 O.T.M. = 1,266.2 Resisting/Overturning Ratio = 1.64 Vertical Loads used for Soil Pressure = 1,537.0 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 546.3 1.96 1,069.7 Soil Over HL (bel. water tbl) 1.96 1,069.7 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = ` Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 549.5 0.79 433.1 Earth @ Stem Transitions = Footing Weight = 412.5 1.38 567.2 Key Weight = Vert. Component = Total = 1,537.0 Ibs R.M.= 2,077.2 ` Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.305 in tlhe above calculation is not valid if the heel soil bearing wessura exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Q%0rESS$DN 01RDUG �yc ND. 83660 n . * EXP. 03I3t(=5 Ile C I V* v OF GA6�FQ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall L1C+i' KW-06016003, Build'20.23.2.14 DESCRIPTION: (04c) 4' ret with top out Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 ORCa BLOCK COMPANY INC Criteria Soil Data Retained Height = 4.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil - 6.33 ft Equivalent Fluid Pressure Method Active Heel Pressure - 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe - 6.00 in = Water height over heel - 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 8.72 ft ...Height to Bottom = 7.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes_cantera-la quinta.ec6 [c] ENERCALC INC 1983.2022 i _ _ - F-- Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil = -1.5 ft at Back of Wall Poisson's Ratio = 0.300 eROFEss/OH a ��4k4v�ERDUC �y 07 w »l m NO 63660 n A * EXP 03/31/2025 s� C I v Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIC# : KW-06016003. Build:20.23.2 14 ORCO BLOCK COMPANY INC (C) ENERCALC INC 1983-2022 DESCRIPTION: (04c) 4' ret with top out Design Summary Stem Construction end Bottom Stem OK Stem OK Design Height Above Ftg ft = 4.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning - 1.66 OK Design Method - ASD ASD Sliding = 1.54 OK Thickness - 6.00 8.00 Global Stability = 2.87 Rebar Size # 4 # 4 Rebar Spacing 32.00 16.00 Total Bearing Load = 2,006 Ibs Rebar Placed at = Center Edge ...resultant ecc. = 10.91 in Design Data Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.760 Soil Pressure @ Toe = 2,264 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 104.2 439.2 Allowable = 2,667 psf Strength Level Ibs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 3,170 psf Service Level ft-#= 439.9 1,468.9 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 10.2 psi OK Moment..... Allowable ft-#= 518.6 1,931.1 Footing Shear @ Heel = 8.5 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 5.9 4.8 Sliding Caics Strength Level psi = Lateral Sliding Force = 650.6 Ibs Shear..... Allowable psi = 52.5 52.6 less 100% Passive Force - 196.8 Ibs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force - 802.2 Ibs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 2.81 5.25 ....for 1.5 Stability = 0.0 Ibs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting No Yes Load Factors Modular Ratio 'n' = 16.11 16.11 Building Code Equiv. Solid Thick. in = 3.39 7.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psl= Seismic, E 1.000 Fy psi - �vn>•sssroN N0. 83660 * EXP. 03/31/2025 sr�r CIVl4 F ar c44��a Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: Beazer homes_cantera_la quinta.ec6 LJC4 : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (C) ENERCALC INC 1983.2022 DESCRIPTION: (04c) 4' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 2.50 Total Footing Width — 3.00 Footing Thickness = 12.00 in Key Width 12.00 in Key Depth = 4.00 in Key Distance from Toe = 0.50 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Heel Factored Pressure = 3,170 Mu': Upward = 359 Mu': Downward = 52 1, Mu: Design = 307 OK 1, phiMn = 2,500 2 Actual 1-Way Shear = 10.21 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacinos Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: phiMn = phi*5'lambda*sgrt(fc)*Sm 0 psf 66 ft-# 454 ft-# 388 ft-# OK ,500 ft-# 8.45 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Q�,�xess,oro w � , IW: NO 83660 D * EXP. 03/31/2025 s yr C / V 0 E OF CA_"� Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (04c) 4' ret with top out ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs It ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 437.5 1.67 729.2 109.0 1.08 117.9 104.2 9.22 960.8 Total = 650.6 O.T.M. = 1,807.9 Resisting/Overturning Ratio = 1.66 Vertical Loads used for Soil Pressure = 2,005.6 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazar homes__cantera_la quinta- (c) ENERCALC INC 1983-2022 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 843.3 2.08 1,756.9 Soil Over HL (bel. water tbl) 2.08 1,756.9 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 633.5 0.79 503.1 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = 50.0 1.00 50.0 Vert. Component = Total = 2,005.6 Ibs R.M.= 2,992.3 . Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Dell @ Top of Wall (approximate only) 0.361 in The above calculation is not valid if the _heel _soil bearing pressure exceeds that of the. t_ae because the wall would then tend to rotate into the retained soil. eROFESS+�ro4 �w415 JERt7UG w� of p NO.83660 n * EXP. 03/31/2025 1P�4 P C / V F OF CA%-% 4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: bearer homes,, cantera., la quinta.ec6 LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (04d) 5' ret with top out Code Reference, Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data Retained Height = 5.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil - 6.33 ft Equivalent Fluid Pressure Method Active Heel Pressure - 35.0 psf/ft Slope Behind Wall - 0.00 Height of Soil over Toe = 6.00 in = Water height over heel - 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load Surcharge Over Heel - 0.0 psf Lateral Load = 148.8 #/ft Adjacent Footing Load = 1,500.0 Ibs Used To Resist Sliding & Overturning ...Height to Top = 9.72 ft Footing Width = 1.50 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 8.72 ft Eccentricity = 0.00 in Used for Sliding & Overturning Load Type = Seismic (E) Wall to Ftg CL Dist = 5.00 ft Axial Load Applied to Stem (Strength Level) Footing Type Spread Footing Base Above/Below Soil 1.5 ft Axial Dead Load = 0.0 Ibs Wind on Exposed Stem = 0.0 psf at Back of Wall - Axial Live Load = 0.0 Ibs (Strength Level) Poisson's Ratio - 0.300 Axial Load Eccentricity = 0.0 in QROFESS/pH rnm m �a �4 N0. 63660 * EXP 03/31/2025 qr C / V � \- F OF CA? �F o Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC4 : KW-06W6003. 801d:20.23.2A4 DESCRIPTION: (04d) 5' ret with top out Design Summary Wall Stability Ratios Overturning = 1.83 OK Sliding = 1.52 OK Global Stability 2.68 Total Bearing Load = 2,700 Ibs ...resultant ecc. = 11.50 in Eccentricity outside middle third Soil Pressure @ Toe = 2,274 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 3,183 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear @ Heel = 8.8 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 896.4 Ibs less 100% Passive Force - 278.4 Ibs less 100% Friction Force s - 1,080.2 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Project File: beazer homes_cantera_la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC ING 1983.2022 Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data -- - - fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data - Wind, W 1.000 Pc Seismic, E 1.000 Fy ft = 2nd Stem OK 5.00 Masonry ASD 6.00 # 4 32.00 Center 0.848 Ibs = 104.2 Ibs = ft-# = ft-# = ft-# = psi = psi = psi = in2 = psf = in = Bottom Stem OK 0.00 Masonry ASD 8.00 # 4 8.00 Edge 0.891 650.6 439.9 2,334.7 518.6 2,617.5 5.9 7.1 52.5 53.0 17.53 91.50 47.0 84.0 2.81 5.25 psi= 2,000 2,000 psi= 32,000 32,000 = No Yes - 16.11 16.11 ins 3.39 7.63 = ASD psi = PSI = QEyOFESSIOH t y Q`• -4 x . c� R5 m Iw �Im � � N0. 03660 n * EXP 03131120M s4r C/V `L �a,� F OF CA0f" Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIGN : RW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1993-2022 DESCRIPTION: (04d) 5' ret with top out Footing Data Toe Width = 0.50 ft Heel Width = 3.00 Total Footing Width = 3.50 Footing Thickness = 12.00 in Key Width = 12.00 in Key Depth = 7.00 in Key Distance from Toe = 0.50 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % �@ 0.0018 Cover @ Top 2.00 Btm: 3.00 in Footing Design Results Toe Heel Factored Pressure = 3,183 Mu': Upward = 370 Mu': Downward = 52 2 Mu: Design = 318 OK 2 phiMn = 2,500 2 Actual 1-Way Shear = 10.73 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Accentable Sizes & SDacincs Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: phiMn = phi*5'lambda*sgrt(fc)*Sm 0 psf 394 ft-# 707 ft-# 312 ft-# OK ,500 ft-# 8.76 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: phiMn = phi*5'lambda*sgrt(fc)*Sm 0 psf 394 ft-# 707 ft-# 312 ft-# OK ,500 ft-# 8.76 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.91 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one Iaye r of horizontal bars: T It two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Z`yOFESS/OV, 4io dERDOG �-a a m m �. 01r" N0. 83660 * E%P 03/31/2025 tr ��qr C 1 _V 1 \.- qa Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LiC# - KW-06016003, BUIId-M-212.14 DESCRIPTION: (04d) 5' ret with top out ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 630.0 2.00 1,260.0 162.3 1.57 254.1 104.2 10.22 1,064.9 Total 896.4 O.T.M. = 2,579.1 Resisting/Overturning Ratio = 1.83 Vertical Loads used for Soil Pressure = 2,700.4 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC NO 18#346V .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 1,341.7 2.33 3.130.E Soil Over HL (bel. water tbl) 2.33 3,130.E Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 28.8 0.25 7.2 Surcharge Over Toe = Stem Weight(s) = 717.5 0.80 573.1 Earth @ Stem Transitions= Footing Weight = 525.0 1.75 918.E Key Weight = 87.5 1.00 87.E Vert. Component = Total = 2,700.4 Ibs R.M.= 4,717.1 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl Q Top of Wall (approximate only) 0.341 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. QROFESS/4H waim No. 83660 * EXP. 03/31/2025 sT�r C / V } L �tia E OF CAL��O ORCO 6' HIGH WALL W/ RETAINING & HEELBACK FOOTING FOR 110 MPH WIND 3 SEC. GUST @a EXP C SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRY STEM. CAP UNIT DESIGN CRITERIA PER THE 2022 CDC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH, f ',,, = 2000 PSI. GENERAL NOTES: --ma-ORCO 6616 CMU GROUTED ONLY @ VERT STEEL 1. CONCRETE BLOCKSHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. #4 VERT DROP -IN BAR @ 32" OIC 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS @ CENTER OF CMU. PROVIDE 24" MIN LAP INTO 8" CMU SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI o #6 STD JOINT 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A REINFORCEMENT @ 12' O/C 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. LEVEL d4CKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D N4 HORZ CONT. I 1 @ 24"OIC 1 CDOWEL L @ EDGE OF 8" CMU 12" U W 4"DIA. SDR 35 PERF PIPE ti b� W/1FTWIDE0F}" 2 U' O 2" CLR GRAVEL WRAPPED W1 yR O p MIRAR 14ON FILTER W E FABRIC TO WITMN I FT OF H FG - SLOPE TO DRAIN. • WATERPROOF BACKSIDE OF RETAINING WALL. {�\f n 2 CCR. ry �• • #4 HORZ. CONT. 1"C1R @12"O/C 3"CLR. 3•CLR. 'A' 'B' 'C'S'D' BARS 2'-0" 2'-9" #4@32" 0/C 3'-0" 3'-0" #4@16" 0/C 4'-0" 3'-3" #4@16" 0/C 5'-0" 3'-6" #4@8" 0/C 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VER7IC4L IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 20' O/C. DETAIL #5 ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. BEAZER HOM CANTERA @a CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SC4LE. I4�ID yER❑OG ( � W � yl�9�zoZ3; NO. 83660 * EXP. 03/3l/2025 SqT C IV %\- 09'� F 0F CA0F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : M-06016663. BuJM 20 23.2.14 ❑RCO BLOCK COMPANY ING DESCRIPTION: (05a) 2' ret with top out -heel footing Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data Retained Height = 2.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.33 ft Equivalent Fluid Pressure Method Active Heel Pressure - 35.0 psf/ft Slope Behind Wall - 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0lbs Axial Live Load = 0.0lbs Axial Load Eccentricity = 0.0 In Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 6.72 ft ...Height to Bottom = 5.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes_cantera_la quinta.ec6 (c) ENIFFICALC INC 1983.2022 i i :I Ik I iI i I Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil _ -1.5 ft at Back of Wall Poisson's Ratio = 0.300 QapF ESS/Ok ��a yERdtJ F Ix nIrn nra. asaao * ExP.0313112025 s qr C, � � 1 V ����► .. F OP CALIFO Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beater homes-cantera_la quinta.ec6 LIC# : KW-06016003, Bulld:20.23.2.14 ORCO BLOCK COMPANY ING (c) ENERCALG INC 1983-2022 DESCRIPTION: (05a) 2' ret with top out -heel footing Design Summary Stem Construction end Bottom Stem OK Stem OK Design Height Above Ftg ft= 2.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.66 OK Design Method = ASD ASD Sliding _ 2.46 OK Thickness - 6.00 8.00 Global Stability = 4.76 Rebar Size # 4 # 4 Rebar Spacing - 32.00 32.00 Total Bearing Load = 1,357 Ibs Rebar Placed at = Center Edge ...resultant ecc. = 11.17 in Design Data - Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.703 Soil Pressure @ Toe = 2,038 psf OK Total Force @ Section Soil Pressure Q Heel = 0 psf OK Service Level Ibs = 104.2 174.2 Allowable = 2,667 psf Strength Level Ibs= Soil Pressure Less Than Allowable Moment.... Actual ACI Factored Q Toe = 2,854 psf Service Level ft-# = 439.9 694.9 ACI Factored @ Heel = 0 psf Strength Level ft-#= Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable ft-# = 518.6 987.8 Footing Shear Q Heel = 4.0 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 1.9 Sliding Calcs Strength Level psi = Lateral Sliding Force = 274.8 Ibs Shear..... Allowable psi = 52.5 52.0 less 100% Passive Force 104.2 Ibs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force =_ - 571.9 Ibs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 2.81 5.25 ....for 1.5 Stability = 0.0 Ibs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psl= 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ration' - 16.11 16.11 Building Code Equiv. Solid Thick. in � 3.39 7.63 Dead Load 1.200 Masonry Block Type - Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = Tsof E551 QAN ¢�a sERatJ � rn m * EXP. 03/31/2025 S Y q r C OF CAL , Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05a) 2' ret with top out —heel footing Footing Data Toe Width = 0.00 ft Heel Width = 2.75 Total Footing Width = 2.75 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 Toe Heel Factored Pressure = 2,854 0 psf Mu': Upward = 0 105 ft-# Mu': Downward = 0 1,148 ft-# Mu: Design = 0 OK 1,043 ft-# OK phiMn = OK - Flush 2,500 Actual 1-Way Shear = 10.73 3.97 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Soacinns Toe: Flush toe condition. No reinforcing required Heel: phiMn = ph'5`lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 0.71 in2 Min footing T&S reinf Area per foot 0.26 in2 fit It one laver of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Q "of ESS 10H 4 F� � w 47 ■■■ Q rn NO.63660 * EXF 03/31/2025 sq C I V �� OF CA0104 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-0601600. Build.M23.2.14 ORCO BLOCk COMPANY INC DESCRIPTION: (05a) 2' ret with top out —heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 157.5 1.00 13.2 0.29 104.2 7.22 Total 274.8 O.T.M. = Resisting/OverturnIng Ratio = 1.66 Vertical Loads used for Soil Pressure = 1,357.2 Ibs Project File: beazer homes_cantera_la quinta.ec6 (o} ENERCALC INC 1983.2022 ...RESISTING..... Force Distance Moment Ibs It ft-# 157.5 Soil Over HL (ab. water tbl) 479.2 1.71 818.E Soil Over HL (bel. water tbl) 1.71 818.E Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = 3.8 Axial Dead Load on Stem = 752.4 " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 465.5 0.28 130.4 Earth @ Stem Transitions = 913.7 Footing Weight = 412.5 1.38 567.2 Key Weight = Vert. Component = Total = 1,357.2 Ibs R.M.= 1,516.1 " Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.286 in The above calculation is not valid it tho hael sail boa drK rressure exceeds thal of the toe. because the wall would then tend to rotate into the retained soil. 4,OF ESS10N w � m a N0. 83660 D * EXP 03/31/2025 s�qr t= / V E of o CA4�f Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05b) 3' ret with top out -heel footing Code Reference. Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data Retained Height = 3.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.33 ft Equivalent Fluid Pressure Method Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load ...Height to Top ...Height to Bottom Load Type 148.8 #/ft = 7.72 ft 6.72 ft Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File; beater homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = -1.5 ft Poisson's Ratio = 0.300 QaOFEss/n,V Q- -a a rt M w �I m Cr Q NO 63660 n A * EXP 03/31/2025 STq r j V F 4F EAL.�f Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY TNG DESCRIPTION: (05b) 3' ret with top out -heel footing Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Design Summary Stem Construction end Bottom_ Stem OK Stem OK Design Height Above Ftg ft = 3.00 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Masonry Overturning = 1.82 OK Design Method - ASD ASD Sliding = 2.00 OK Thickness - 6.00 8.00 Global Stability = 3.82 Rebar Size - # 4 # 4 Rebar Spacing - 32.00 16.00 Total Bearing Load = 1,805 Ibs Rebar Placed at Center Edge ...resultant ecc. = 11.06 in Design Data Eccentricity outside middle third fb/FB + fa/Fa 0.848 0.489 Soil Pressure @ Toe = 2,081 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 104.2 274.8 Allowable = 2,667 psf Strength Level Ibs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 2,914 psf Service Level ft-# = 439.9 945.5 ACI Factored @ Heel = 0 psf Strength Level ft-# _ Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable ft-#= 518.6 1,931.1 Footing Shear @ Heel = 3.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 5.9 3.0 Sliding Calcs Strength Level psi = Lateral Sliding Force = 439.2 Ibs Shear..... Allowable psi = 52.5 52.3 less 100% Passive Force - 104.2 Ibs Anet (Masonry) in2 = 17.53 91.50 less 100% Friction Force =_ - 773.5 Ibs Wall Weight psf = 47.0 84.0 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 2.81 5.25 ....for 1.5 Stability = 0.0 Ibs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm pgi= 2,000 2,000 considered in the calculation of soil bearing pressures. Fs psi= 32,000 32,000 Solid Grouting = No Yes Load Factors Modular Ratio 'n' = 16.11 16.11 Building Code Equiv. Solid Thick. in= 3.39 7.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psl= Seismic, E 1.000 Fy psi = QROFESSI�N 4 �r4ti yrG1:tDL7� � ti� wv �cti� c m ila � n1� N0.85660 * EXF. 03131/2025 C IV F l OF CAL�F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23 2 14 ORCO BLOCK COMPANY INC DESCRIPTION: (05b) 3' ret with top out -heel footing Footing Data Toe Width = 0.00 ft Heel Width = 3.00 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth - 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File; Beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 Toe Heel Factored Pressure = 2,914 0 psf Mu': Upward = 0 341 ft-# Mu': Downward = 0 1,848 ft-# Mu: Design = 0 OK 1,507 ft-# OK phiMn = OK - Flush 2,500 Actual 1-Way Shear = 10.73 3.57 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: Flush toe condition. No reinforcing required. Heel: phiMn = ph'5'lambda'sgrt(fc)"Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one laver of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in 0,78 02 0.26 in2 /ft If two lavers of {horizontal gars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in �R6PESS10 yEFtDUO N0. 83660 D EXP. 03/31/2025 s9r CIV�1.. R OF C401 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016 m, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05b) 3' ret with top out_heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING....Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 280.0 1.33 373.3 55.1 0.66 36.3 104.2 8.22 856.6 Total = 439.2 O.T.M. = 1,266.2 Resisting/Overturning Ratio = 1.82 Vertical Loads used for Soil Pressure = 1,804.5 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: bearer homes_cantera_la quinta.ecG 1 (c) ENERCALC INC 1983-2022 1 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 805.0 1.83 1,475.8 Soil Over HL (bel. water tbl) 1.83 1,475.8 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 549.5 0.29 158.4 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = Vert. Component = Total = 1,804.5 Ibs R.M.= 2,309.2 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.300 in The above calculation is not vatid if the heel soi[ bearing press_ure_excoods that of the toe, because the wall would then tend to rotate into the retained soil. eRpfESSIQM i�4r`4 �jSRDUG Fc 0m N0. 83660 * EXP 03/31/2025 s ar C f V F OF CA'0* Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I.IC4 - RW-06016003. Buiid:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05c) 4' ret with top out -heel footing Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 4.00 ft Wall height above soil = 6.33 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Project File: beazer homes_cantera—la quinta.ec6 ` (c) ENERCALC INC 1983-2022 J Soil Data j Allow Soil Bearing = 2,666.6 psf + Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingllSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 8.72 ft ...Height to Bottom = 7.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) I 1 i Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 ft Footing Type Spread Footing Base Above/Below Soil _ 1.5 ft — at Back of Wall Poisson's Ratio = 0.300 QROFESS�O� ti� rL�' �Y►� c m'm eva. 835h0 0iM Yr EXP. 0513I/2025 4� r C II V } V . ti$tP E OF CAL�40 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC f 0:1-2u22 DESCRIPTION: (05c) 4' ret with top out -heel footing Design Summary Wall Stability Ratios Overturning = 1.83 OK Sliding = 1.70 OK Global Stability 3.25 Total Bearing Load = 2,309 Ibs ...resultant ecc. = 11.72 in Eccentricity outside middle third Soil Pressure ® Toe = 2,374 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 3,323 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear @ Heel = 4.1 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 650.6 Ibs less 100% Passive Force 104.2 Ibs less 100% Friction Force = - 1,004.5 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 f'c Seismic, E 1.000 Fy 2nd Stem OK ft = 4.00 = Masonry = ASD 6.00 _ # 4 = 32.00 Center 0.646 Bottom Stem OK 0.00 Masonry ASD 8.00 # 4 16.00 Edge 0.760 Ibs = 104.2 439.2 Ibs = ft-# = 439.9 1,468.9 ft-# = ft-# = 518.6 1,931.1 psi = 5.9 4.8 psi = psi = 52.5 52.6 in2 = 17.53 91.50 psf = 47.0 84.0 in = 2.81 5.25 psi = 2,000 2,000 psi = 32,000 32,000 = No Yes = 16.11 16.11 in= 3.39 7.63 psi = psi = ASID QRorEss ��o yERdug F ( Arn m sa NO. s3e00 n * �xr. osrai.aozs ,p v qr C IV 1 �- ¢�,. F OF c jk0o Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-C6016003, 6L1Ifd:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05c) 4' ret with top out —heel footing Footing Data Toe Width = 0.00 ft Heel Width = 3.25 Total Footing Width = 3.25 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC; 1983-2022 Toe Heel Factored Pressure = 3,323 0 psf Mu': Upward = 0 596 ft-# Mu': Downward = 0 2,758 ft-# Mu: Design = 0 OK 2,162 ft-# OK phiMn = OK - Flush 2,500 Actual 1-Way Shear = 10.73 4.12 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: Flush toe condition. No reinforcing required. Heel: phiMn = ph'5'lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 0.84 in2 Min footing T&S reinf Area per foot 0.26 in2 ift If one la er of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in eRprtessroro m rrk Ia, PIM No. 83660 * EXP. 63/31/2625 * . C/ v (IF CA01 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIN : KW-06016603. 9ulld:P6.0.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05c) 4' ret with top out —heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs ft ft-# HL Act Pres (ab water tbl) 437.5 1.67 729.2 HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = 109.0 1.08 117.9 Added Lateral Load = 104.2 9.22 960.8 Load @ Stem Above Soil = Total _ 650.6 O.T.M. = 1,807.9 Resisting/OverturnIng Ratio = 1.83 Vertical Loads used for Soil Pressure = 2,309.3 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes _cantera_la quinta.ec6 to tNERCALC INC 1983-2022 Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth @ Stem Transitions= Footing Weight = Key Weight = Vert. Component = .....RESISTING..... Force Distance Ibs ft 1,188.3 1.96 1.96 633.5 0.29 487.5 1.63 Moment ft-# 2,327.2 2,327.2 186.4 792.2 Total = 2,309.3 Ibs R.M.= 3,305.7 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.349 in The above calculation is not valid if the heel soil bearinu pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. QRpp E 55 1 o,4,4 � Q7 rf1' In N0. 83660 * EXP. 03/31/2025 Syr C/V1�- ¢a'4 R OF Ckof Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05d) 5' ret with top out -heel footing Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Project File: beater homes_canteraJa quinta.ec6 (c) ENERCALC INC 1983-2022 Criteria Soil Data Retained Height = 5.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.33 ft Equivalent Fluid Pressure Method I Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 � Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft ; • yrT Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 148.8 #/ft ...Height to Top = 9.72 It ...Height to Bottom = 8.72 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load = 1,500.0 Ibs Footing Width = 1.50 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 5.00 It Footing Type Spread Footing Base Above/Below Soil at Back of Wall 1.5 ft Poisson's Ratio = 0.300 QROFESS 1�3 aeRDIJ co rt5 m w O m N0. 63660 D y1• EXP 03/31/2025 sT C f V 4rfi 0, CA" * Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beater homes_cantera_ia quinta.ec6 LIC::1 . KW-06016003, Build:20.23.2.14 ORCO BL06K COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (05d) 5' ret with top out -heel footing Design Summary Wall Stability Ratios Overturning = 1.94 OK Sliding = 1.59 OK Global Stability = 2.86 Total Bearing Load = 3,017 Ibs ...resultant ecc. = 11.37 in Eccentricity outside middle third Soil Pressure @ Toe = 2,507 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 3,510 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear @ Heel = 2.1 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 896.4 Ibs less 100% Passive Force 104.2 Ibs less 100% Friction Force - 1,323.0 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Masonry Data - Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 Pc Seismic, E 1.000 Fy 2nd Stem OK ft = 5.00 = Masonry ASD 6.00 # 4 32.00 Center 0.848 Ibs= 104.2 Ibs = ft-# = ft-# = ft-# = psi = psi = psi = in2 = psf = in = Bottom Stem OK 0.00 Masonry ASD 8.00 # 4 8.00 Edge 0.891 650.6 439.9 2,334.7 518.6 2,617.5 5.9 7.1 52.5 53.0 17.53 91.50 47.0 84.0 2.81 5.25 psi = 2,000 2,000 psi = 32,000 32,000 = No Yes = 16.11 16.11 In = 3.39 7.63 psi = psi = ASD V%OFESS/aN 4 rr.Q�O ��gQLI„ FS. c� rri m • 0 N0. 83660 D A * EXP. 03/31/2025 C ' V Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# . KW-oaaim 43. 13010:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (05d) 5' ret with top out —heel footing Footing Data Toe Width = 0.00 ft Heel Width = 3.50 Total Footing Width = 3.50 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983.2022 Toe Heel Factored Pressure = 3.510 0 psf Mu': Upward = 0 1,280 ft-# Mu': Downward = 0 3.903 ft-# Mu: Design = 0 OK 2,623 ft-# NG phiMn = OK - Flush 2,500 Actual 1-Way Shear = 10.73 2.15 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = Flush toe condition. No reinforcing required. Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: Flush toe condition. No reinforcing required. Heel: phiMn = ph'5`lambda`sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area 0.91 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in QROFESS/6 af FDLI 01 �c rtA m m NO 83660 * EXP 03/31/2025 V 1 9r� Op CA`\�0¢ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beater homes_cantera_la quinta.ec6 L1C# : KW-06016003. Budd:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 198E-2022 DESCRIPTION: (05d) 5' ret with top out —heel footing Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... M Force Distance oment Force Distance Moment Item Ibs It ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 630.0 2.00 1,260.0 Soil Over HL (ab. water tbl) 1,629.2 2.08 3,394.1 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.08 3,394.1 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = 145.2 3.25 471.8 Adjacent Footing Load = 162.3 1.57 254.1 Axial Dead Load on Stem = Added Lateral Load = 104.2 10.22 1,064.9 ' Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = = Surcharge Over Toe = Stem Weight(s) = 717.5 0.30 214.4 Earth @ Stem Transitions= Total 896.4 O.T.M. = 2,579.1 Footing Weight = 525.0 1.75 918.8 Key Weight = Resisting/Overturning Ratio = 1.94 Vert. Component = Vertical Loads used for Soil Pressure = 3,016.8 Ibs Total = 3,016.8 Ibs R.M.= 4,999.0 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.376 in The above calculation is not _valid _if the heel soil bearing pressure exceeds that of the toe. because the wall would then tend to rotate into the retained soil. QaOFESS10 -4E1 U o y fic .W olmi NO. 83660 D A yt EXP 03/31/2025 �T4re C 1 V Op CA41f ORCO 12" SQ. PILASTER W/RETAINING DESIGN CRITERIA PER THE 2011 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI Cal 28 DAYS. 5. REINFORCING STEEL: GRADE 60 6. MASONRY COMPRESSION STRENGTH, f ',,, = 2000 PSI. SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 AND 4 OF THE MASONRY STEM. ORCO 12612 PILASTER CMU (SOLID GROUTED) 3-112" CLR. (2) #4 VERT. _ DROP -IN BARS #4 DOWELS W1 24' M/N. Z EXTENSION INTO CMU z J Q u 12„ Qc N M �C 7' TO DAYLIGHT �� #4 HORZ. — 0 9" 0/C EACH WAY FOR 1/0 MPH EXPOSURE C WIND GENERAL NOTES: 1, CONCRETE BLOCKSHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. CAP UNIT 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOC4TED. 5. CONCRETE BLOCK SHALL BE LAID IN A STACK BOND PATTERN. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. B. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAYBE WET -SET 1-1/2"INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. LEVEL BACKFILL 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL COMPACTED TO OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. MIN. 90"/" RELA77VE COMPACTION PER 11. FIRST INSPECTION TO BEAFTER FOOTING TRENCHES ARE READY FOR ASTM 1557-D CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPEC77ON TO BE WHEN THE REQUIRED VERTIG4L IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHERE MTERSEC77ON BLOCK WALLS OCCUR. EIR 1--Y 12" 1 'B' SQUARE FOOTING N07E' ONLY RUN WALL FOOTING HORIZONTAL REINFORCEMENT THROUGH PILASTER FOOT/NG, WHEN INTERSECTING ORCO 12612 PILASTER CMU (SOLID 4" DIA. SDR 35 PERF PIPE W/ IFT WIDE OF }" GRAVEL WRAPPED W1 MIRAF1140N FILTER FABRIC TO WIRaN 1FT OF FG - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL. 2'-0" 3'-0" 4'-0" 3'-0" N/A 3'-0" N/A 3'-3" N/A 5'-0" 3'-6" 5" 12' N 4TICAL (AS SHOWN) PILASTER CROSS SECTION DETAIL NOT TO S01LE ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. A DETAIL #6 BEAZER HOMES a '/ 02 m CANTERA @ CORAL MOUNTAIN NO. 83660 D TRACT No. 31249 LA QUINTA, CALIFORNIA * EXP. 0313112025 sT4TF I.ALOTE: DIMENSIONS ARE NOT TO SC11LE. OF CA0F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall 1.ICu : KW-06016003, Build:20.23.2.14 DESCRIPTION: (06a) Pilaster w/2' ret Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 2.00 ft Wall height above soil = 6.67 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0lbs Axial Live Load = 0.0lbs Axial Load Eccentricity = 0.0 in ORtO BLOCK COMPATi} WC Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIiSoil Friction - 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 147.8 #/ft ...Height to Top = 6.94 ft ...Height to Bottom = 5.94 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File' beater homes-cantera_la quinla.ec6 (c) ENERCALC INC 1983-2022 ■ I II ' 1 J Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 QaOFEss ro,ya 4�0 �r�szauc �, q z . olA NO. 83660 D 7k EXP. 03/31/2025 * . CIV,\, 4��P F OF CA%-%q Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I IC.. Cl^1-flii;i?ii{;l?:i, Build: 20-23.2.14 DESCRIPTION: (06a) Pilaster w/2' ret Design Summary Wall Stability Ratios Overturning = 1.99 OK Sliding 2.11 OK Global Stability = 3.00 Total Bearing Load = 1,118 Ibs ...resultant ecc. r 8.10 in Eccentricity outside middle third Soil Pressure @ Toe = 903 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,667 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,265 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 6.1 psi OK Footing Shear @ Heel = 3.3 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 260.9 Ibs less 100% Passive Force - 104.2 Ibs less 100% Friction Force = - 447.2 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Project File: beater homes cantera_la.qu€nta.eC6 ORCO BLOCK COMPANY INC (C) ENEACALC INC 1983.2022 Stem Construction Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Wall Weight Rebar Depth 'd' Masonry Data Vertical component of active lateral soil pressure IS NOT f'm considered in the calculation of soil bearing pressures. Fs Solid Grouting Load Factors Modular Ratio 'n' Building Code Equiv. Solid Thick. Dead Load 1.200 Masonry Block Type Live Load 1.600 Masonry Design Method Earth, H 1.600 Concrete Data Wind, W 1.000 f'c Seismic, E 1.000 Fy Bottom Stem OK ft = 0.00 = Masonry ASD _ 12.00 # 4 16.00 Edge 0.211 Ibs= 173.4 Ibs = ft-#= 712.9 ft-# = 3,371.6 psi = 1.2 psi = psl= 51.1 in2 = 139.50 psf = 43.9 in = 9.00 psi = 2,000 psi = 32,000 Yes = 16.11 in= 11.63 psi w psi = ASD ASD QRaFEss+ory •r4�V d��BOO' Fy w O� m NO 83660 D A * EXP 03/31/2025 V 9rf OF CAL�4flSi Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (06a) Pilaster w/2' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.00 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in ORCO BLOCK COMPANY INC Footing Design Results Project File: beezer homes_canteraJa qulnta.ec6 (c) ENERCALC INC 1983-2022 Toe Heel Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one laver of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in 00 ft-Ibs 00 ft-Ibs 0.78 in2 0.26 in2 /ft If two lavers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in V%OFESS/O4, ���w9�yERDl1 Fc Q•� Z yst m W ❑I m A NO 83660 A * EXP 03/31/2025 sqf C 1 v OF cw')*9 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 KW-t i-som. Wid:M23.2.14 ORCO BLOCK COMPANY INC (c) E-WERCALC INC 1983.2022 DESCRIPTION: (06a) Pilaster w/2' ret Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 157.5 1.00 157.5 Soil Over HL (ab. water tbl) 230.0 2.50 575.0 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.50 575.0 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = 103.4 7.44 769.6 Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 57.5 0.50 28.8 Surcharge Over Toe = Stem Weight(s) = 380.5 1.50 570.8 Earth Q Stem Transitions= Total _ 260.9 O.T.M. = 927.1 Footing Weight = 450.0 1.50 675.0 Key Weight = Resisting/Overturning Ratio = 1.99 Vert. Component = Vertical Loads used for Soil Pressure = 1,118.0 Ibs Total = 1,118.0 Ibs R.M.= 1,849.5 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.121 in The above calculation is not valid ff the heel soil bearing pressure exceeds that of tiles too. because the wall would then tend to rotate into the retained soil. QRpfEss+oH IeRDU NO 83660 D * EXP 03/31/2025 ' (+T4r C r V OF C A0* Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-46016003. Build:20.23.2.14 DESCRIPTION: (06b) Pilaster w/3' ret Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 ORCO BLOCK COMPANY INN Criteria Soil Data Retained Height = 3.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.67 ft Equivalent Fluid Pressure Method Active Heel Pressure - 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingllSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load - 147.8 #/ft ...Height to Top - 7.94 ft ...Height to Bottom = 6.94 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beater homescanteraja quinta.ec6 (c) ENERCALC INC 1983.2022 Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 QRoFESS4 0 CZ) rn m NO 83660 * EXP 03/31/2025 Sq CIv 1V T10' TF OF CAl\F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LICO : KW06016003. Suild:20.23.2.14 DESCRIPTION: (06b) Pilaster w/3' ret Project File: beazer homes_cantera_la quinta.ec6 CIRCA BLOCK COMPANY ING [c] ENERGALC INC 1983.2022 Design SU1111mary Stem Construction Bottom_ _ Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning = 1.77 OK Design Method ASD ASD Sliding = 1.60 OK Thickness = 12.00 Global Stability = 2.60 Rebar Size - # 4 Rebar Spacing = 16.00 Total Bearing Load = 1,277 Ibs Rebar Placed at = Edge ...resultant ecc. = 9.01 in Design Data Eccentricity outside middle third fb/FB + fa/Fa = 0.274 Soil Pressure @ Toe = 1,136 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 260.9 Allowable = 2,667 psf Strength Level Ibs= Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 1,591 psf Service Level ft-#= 927.1 ACI Factored @ Heel = 0 psf Strength Level ft-# = Footing Shear @ Toe = 8.0 psi OK Moment..... Allowable = 3,371.6 Footing Shear @ Heel = 4.8 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 1.9 Sliding Calcs Strength Level psi = Lateral Sliding Force = 383.4 Ibs Shear..... Allowable psi = 51.2 less 100% Passive Force 104.2 Ibs Anet (Masonry) in2 = 139.50 less 100% Friction Force - 510.8 Ibs Wall Weight psf = 43.9 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 9.00 ....for 1.5 Stability = 0.0 Ibs OK Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting _ Yes Load Factors Modular Ratio 'n' = 16.11 Building Code Equiv. Solid Thick. in = 11.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data -- Wind, W 1.000 f'c psi Seismic, E 1.000 Fy psi = QaoFESS/aN w � m NO 83660 yt EXP 03/31/2025 �rqr C IV F of CA0V Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: Beazer homes cantera_fa quinta.ec6 I LICK : KW-06016003, I3uild:26.23.2.id C]RGfl BLOCK COMPANY INC (c) ENERCAL.0 INC 1983-2622 I DESCRIPTION: (06b) Pilaster w/3' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.00 Total Footing Width - 3.00 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Hee Factored Pressure = 1,591 Mu': Upward = 678 Mu': Downward = 187 Mu: Design = 491 OK phiMn = 2,500 2 Actual 1-Way Shear = 8.04 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceotable Sizes & SQacinas Toe: phiMn = ph*5*lambda'sgrt(fc)`Sm Heel: phiMn = ph*5*lambda`sgrt(fc)'Sm Key: No key defined I 0 psf 2 ft-# 446 ft-4 444 ft-# OK ,500 ft-# 4.77 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.78 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one laver of horizontal bars: It two is ers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in eRpFESS/oM/ N rn m W aI A NO 03660 D * EXP 03/31/2025 S 7 F OF CA F9 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I IC,f : KW-06016003, Build:20.23.2.14 DESCRIPTION: (06b) Pilaster w/3' ret ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) 280.0 1.33 373.3 HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = 103.4 8.44 873.1 Load @ Stem Above Soil = Total = 383.4 O.T.M. = 1,246.4 Resisting/OverturnIng Ratio = 1.77 Vertical Loads used for Soil Pressure = 1,276.9 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 345.0 2.50 862.5 Soil Over HL (bel. water tbl) 2.50 862.E Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = 57.5 0.50 28.8 Surcharge Over Toe = Stem Weight(s) = 424.4 1.50 636.6 Earth @ Stem Transitions = Footing Weight = 450.0 1.50 675.0 Key Weight = Vert. Component = Total = 1,276.9 Ibs R.M.= 2,202.9 • Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.170 in The above calculation is not valid if the heal soil bearing pressure exceeds that of the toe, hegguse the wall would then fend to rotate into the retained soil. 9%0FEssi` H m r. W a QI b NO.83660 * EXP. 03/31/2025 s�q C I V TF OF c4ofa4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (06c) Pilaster w/4' ret Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 ORCO BLOCK COMPANY INC Criteria Soil Data Retained Height = 4.00 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.67 ft Equivalent Fluid Pressure Method Active Heel Pressure — 35.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel — 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0lbs Axial Live Load = 0.0lbs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 136.4 #/ft ...Height to Top = 8.94 ft ...Height to Bottom = 7.94 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazor homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Nam Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil _ — 0.0 ft at Back of Wall Poisson's Ratio = 0.300 QROFESS/0N �W¢a ��RBUG -P �u c� z w'm m a o l A NO 63660 D EXP 03/31/2025 y� Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LTCfe i Kw-06016003, BOU20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (06c) Pilaster w/4' ret Project File: beazer homes_cantera—la quinta.ec6 (o) ENERCALC INC 1983-2022 Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" Masonry Overturning = 1.83 OK Design Method = ASD Sliding = 1.37 Ratio < 1.5! Thickness = 12.00 Global Stability — 2.47 Rebar Size — # 4 Spacing = 16.00 rRebar Total Bearing Load = 1,560 Ibs Rebar Placed at = Edge ...resultant ecc. = 9.04 in Design Data - Eccentricity outside middle third fb/FB + fa/Fa = 0.349 Soil Pressure @ Toe = 1,193 psf OK Total Force @ Section 0 U Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 375.5 • Allowable = 2,667 psf £ Strength Level Ibs = ^� Soil Pressure Less Than Allowable Moment .... Actual ACI Factored @ Toe — 1,670 psf Service Level ft-#= 1,179.2 ,T tY ACI Factored @ Heel = 0 psf Strength Level ft-# _ Footing Shear @ Toe = 9.0 psi OK Moment..... Allowable = 3,371.6 Footing Shear @ Heel = 6.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 2.7 Sliding Calcs Strength Level psi = Lateral Sliding Force = 533.0 Ibs Shear..... Allowable psi = 51.3 less 100% Passive Force - 104.2 Ibs Anet (Masonry) in2 = 139.50 less 100% Friction Force =_ - 624.0 Ibs Wall Weight psf = 41.2 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 9.00 ....for 1.5 Stability = 71.3 Ibs NG Masonry Data - Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors-- Modular Ration' = 16.11 Building Code Equiv. Solid Thick. in = 11.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD eRoPEss/aN � 47 Stl m vlAl NO 83660 D * EXP 03/31/2025 iP)�r C I V P��¢ F OF ct00 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 I C4 : 4(VV-06016003. Bulld:20M;2.14 ORCO BLOCK COMPANY INC (0) ENERCALC INC 1983-2022 DESCRIPTION: (06c) Pilaster w/4' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.25 Total Footing Width = 3.25 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Heel Toe: phiMn = ph"5'lambda`sgrt(fc)'Sm Heel: phiMn = ph'5'lambda'sgrt(fc)`Sm Key: No key defined 0 psf 25 ft-# 801 ft-# 776 ft-# OK ,500 ft-# 6.62 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.84 in2 Min footing T&S reinf Area per foot 0.26 in2 ift Ii ana layer of horizontal bars: If two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in �RpFE55rdry� �a$R DOGO fic co m {1l m ,'.4 DIM N6, 03660 E%P OVW2625 k s ar C f V } ,11t+`¢ 11 C11100 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LICE - KW-06016003, Build:20,23.2.14 DESCRIPTION: (06c) Pilaster w/4' ret ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pros (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 437.5 1.67 95.5 9.44 729.2 901.4 Total 7 533.0 O.T.M. = 1,630.6 Resisting/Overturning Ratio = 1.83 Vertical Loads used for Soil Pressure = 1,559.9 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Project File: boozer homes_cantera_la quinta.ec6 (c) ENERCALC INC 19934622 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 575.0 2.63 1,509.4 Soil Over HL (bel. water tbl) 2.63 1,509.4 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = 57.5 0.50 28.8 Surcharge Over Toe = Stem Weight(s) = 439.9 1.50 659.9 Earth @ Stem Transitions = Footing Weight = 487.5 1.63 792.2 Key Weight = Vert. Component = Total = 1,559.9 Ibs R.M.= 2,990.2 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.181 in I lie above calculation is not valid if the heel sail boring pressure exceeds that of the Joe because the wall would then tend to ratale into the retained soil. QaoFEssroN ¢wo �ERtsu � u m �ytl m ❑ m is ply W 63660 * E%P 03mao25 119r C I V `L ¢ENV E OF CAL�F� Project Title: Engineer: Project ID: Project Descr: Cantilevered ReWining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (06d) Pilaster w/5' ret Code Reference. Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = 5.00 ft Wall height above soil = 6.67 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in ORCO BLOCK COMPANY INC Soil Data Allow Soil Bearing = 2,666.6 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 126.7 #/ft ...Height to Top = 9.94 ft ...Height to Bottom = 8.94 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beater homes_cantera_la qulnta.ec6 (C) ENERCALC INC 1N3.2022 iI Wp�l l Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil _ at Back of Wall 0.0 ft Poisson's Ratio 0.300 PROFESS/0 --ieRDU C w a. DID NO. 83660 k EXP. 03/31/2025 * . S4 C I V l4 TF OF CA41ffl4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (06d) Pilaster w/5' ret Project File: beazer homes_cantera_la quinta.ec6 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" = Masonry Overturning - 1.87 OK Design Method = ASD Sliding = 1.40 Ratio < 1.5! Thickness = 12.00 Global Stability = 2.33 Rebar Size = # 4 Rebar Spacing = 16.00 Total Bearing Load = 1,958 Ibs Rebar Placed at = Edge V ...resultant ecc. = 9.34 in Design Data •. Eccentricity outside middle third fb/FB + fa/Fa _ 0.464 p i Soil Pressure @ Toe = 1,343 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 526.2 Allowable = 2,667 psf Strength Level Ibs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe 1,880 psf Service Level ft-#= 1,566.2 ACI Factored @ Heel 0 psf Strength Level ft-# = Footing Shear @ Toe = 10.7 psi OK Moment..... Allowable = 3,371.6 Footing Shear @ Heel = 8.6 psi OK Allowable = 75.0 psi Shear.....Actual Service Level psi = 3.8 Sliding Calcs Strength Level psi = Lateral Sliding Force = 718.7 Ibs Shear..... Allowable psi = 51.3 less 100% Passive Force - 222.8 Ibs Anet (Masonry) in2 = 139.50 less 100% Friction Force - 783.0 Ibs Wall Weight psf = 38.6 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 9.00 ....for 1.5 Stability = 72.2 Ibs NG Masonry Data Vertical component of active lateral soil pressure IS NOT f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors----- Modular Ratio'n' = 16.11 Building Code Equiv. Solid Thick. in = 11.63 Dead Load 1.200 Masonry Block Type - Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD Q,pFE581a ¢�a PERDU u Qj rf5 ' r„ 1a_ n!x NO.83660 1r EXP. 031311202E sq C f V %\, FE OF cA1.�4�4 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File; beater homes_canteraJa quinta.ec6 LICK: KW•06016003. Build 20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALE fT+fC 9963-ZQ7.2 DESCRIPTION: (06d) Pilaster w/5' ret Footing Data Toe Width = 1.00 ft Heel Width = 2.50 Total Footing Width = 3.50 Footing Thickness = 12.00 in Key Width = 12.00 in Key Depth = 5.00 in Key Distance from Toe = 1.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe Heel Toe: phiMn = ph"5'lambda`sgrt(fc)'Sm Heel: phiMn = ph'5'lambda'sgrt(fc)'Sm Key: phiMn = phi"5'lambda'sgrt(fc)'Sm 0 psf 83 ft-# ,305 ft-# ,222 ft-# OK ,500 ft-# 8.62 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 0.91 in2 Min footing T&S reinf Area per foot 0.26 in2 ift If one laver of horizontal pars: if two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in taoeessrOhl 4w4 ,ERntl � � � CIA N0. 03660 * EV 03/31/2025 �k s � C I V TF 0r CA0, Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 I.ICO : KW-06016003, Bulid:2023.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-202? DESCRIPTION: (06d) Pilaster w/5' ret Summary of Overturning & Resisting (Forces & Moments .....OVERTURNING..... .....RESISTING..... M Force Distance oment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 630.0 2.00 1,260.0 Soil Over HL (ab. water tbl) 862.5 2.75 2,371.9 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.75 2,371.9 Hydrostatic Force Water Table Buoyant Force = Sloped Soil Over Heel = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem = Added Lateral Load = 88.7 10.44 925.7 Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 57.5 0.50 28.8 - Surcharge Over Toe = Stem Weight(s) = 450.1 1.50 675.2 Earth @ Stem Transitions = Total 718.7 O.T.M. = 2,185.7 Footing Weight = 525.0 1.75 918.8 Key Weight = 62.5 1.50 93.8 Resisting/OverturnIng Ratio = 1.87 Vert. Component = Vertical Loads used for Soil Pressure = 1,957.6 Ibs Total = 1,957.6 Ibs R.M.= 4,088.3 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wail due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.207 in The above calculation is not valid it the heel soli bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. eRofessra wrn NO- 83660 ID * EXP 03/31/2025 sT4r C I V E OF CA0FO ORCO ENTR Y GA TE PILASTER FOR 1/0 MPH EXPOSURE C WIND CONDITIONS #4 VERTICAL DROP -IN BARS @ 16" 0/C AND - EA. CORNER #4 TIES @24' 0/C STEEL POST PER L. S. PLANS #4 DOWELS W/ 24' MIN. EXTENSION INTO CMU. @ 16" 0/C J 33' 8" 6 v /8" 0 CAPPER L. S. PLANS VOID AREA DO NOT GROUT 32" SQ. ■ #4 BARS @ 9" O/C EACH WAY 3" CLR (4) #5 VERTS W/ #3 LOOP TIES @ l0' 0/C 4'-I0' SQ. FOOTING DESIGN CRITERIA PER THE 2022 COC. 1. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF + j INCR. FOR WIND/SEISMIC PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60 6. MASONRY COMPRESSION STRENGTH, f',,, = 2000 PSI. GENERAL NOTES: 1, CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90, NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACKK, PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. B. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9, BLOCK STEM MAY BE WET -SET 1-112" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC BLOCK STEM MAY BE PLACED TO l3" EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL 15 READY TO GROUT. 12. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DETAIL #J 1 6E"ER HOME CANTERA @ CORAL MOUNTAIN TRACT No. 31249 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. e�LpFESSION 3�RDOG c7 iL ^C 2 NO, 83660 * EXP. 0315112025 F OF CA0 0 Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC#: KW-06016003, Build:20.23,2,14 DESCRIPTION: (07) 32" Pilaster Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Retained Height = Wall height above soil = Slope Behind Wall = Height of Soil over Toe = Water height over heel = aACO BACK CbMPANY INC Soil Data 0.33 ft Allow Soil Bearing = 2,666.6 psf 7.50 ft Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft 0.00 4.00 in = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 834.2 #/ft ...Height to Top = 5.83 ft ...Height to Bottom = 4.83 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes-cantera_la quinta.ec6 (c) ENr:ACALC INC 19EIM022 Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio - 0.300 "QROFESS � a ern i u m w 0 M. W D A N0. 83660 * EXP 03/31/2025 r� C / V 'ff• OF OQ. C A'- t F Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (07) 32" Pilaster Project File. bearer homes-cantera_;a qulnta.ec6 (c) ENERCALC INC 1983.2022 Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft= 0.00 Wall Stability Ratios Wall Material Above "Ht" - Masonry Overturning = 1.28 Ratio < 1.5! Design Method = ASD Sliding = 1.38 Ratio < 1.5! Thickness = 16.00 Global Stability 5.02 Rebar Size # 4 Rebar Spacing = 16.00 Total Bearing Load = 1,955 Ibs Rebar Placed at 28 in V ...resultant ecc. = 22.53 in Design Data - 0 Eccentricity outside middle third fb/FB + fa/Fa = 0.288 4 Soil Pressure @ Toe = 2,400 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 585.9 4� Allowable = 2,667 psf Strength Level Ibs = ` Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe 3,360 psf Service Level ft-#= 3,114.4 ACI Factored @ Heel 0 psf Strength Level ft-# = Footing Shear @ Toe = 19.1 psi OK Moment..... Allowable = 10,778.3 Footing Shear @ Heel = 3.5 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 3.1 Sliding Calcs Strength Level psi = Lateral Sliding Force = 614.9 Ibs Shear..... Allowable psi = 52.0 less 100% Passive Force - 64.8 Ibs Anet (Masonry) in2 = 187.50 less 100% Friction Force =_ - 782.1 Ibs Wall Weight psf = 138.3 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 28.00 ....for 1.5 Stability = 75.5 Ibs NG Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors Modular Ratio 'n' - 16.11 Building Code Equiv. Solid Thick. in = 15.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 f'c psi = Seismic, E 1.000 Fy psi = ASD eRoRESS1Qk 10 �ERai1 r 01 ; , a7 rtl • m a �b N0. 83660 > * E%P.0313112085 STD C r V rF of CND- itl¢ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I_ICN : KW.66016003. Build:26.23.2.14 DESCRIPTION: (07) 32" Pilaster Footing Data Toe Width = 1.75 It Heel Width = 3.08 Total Footing Width = 4.83 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft Pc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Project File: beazer homes_cantera_la quinta.ec6 ❑RCO BLOCK 001APANY INC (c) ENERCALC INC 198M022 Footing Design Results Toe Heel Factored Pressure = 3,360 Mu': Upward = 3,290 Mu': Downward = 478 Mu: Design = 2,812 NG phiMn = 2,500 2 Actual 1-Way Shear = 19.12 Allow 1-Way Shear = 40.00 4 Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0. Footing Allow. Torsion, phi Tu = 0. If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & SDacinas Toe: phiMn = ph*5*lambda*sgrt(fc)*Sm Heel: phiMn = ph*5*lambda*sgrt(fc)*Sm Key: No key defined 0 psf 0 ft-# 517 ft-# 517 ft-# OK ,500 ft-# 3.48 psi 0.00 psi 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 1.25 in2 Min footing T&S reinf Area per foot 0.26 in2 At If one laver of horizontal bars: If two lavers of horizontai bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Qgof>ssro �p�9v�E�tf7t! � Fy rn w p m NO. 83660 * EXP 03/31/2025 yt qr C ! V 1 v P OF C-m-1FQ ¢ Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LICY : KW06016003, Build:20.23 2.14 DESCRIPTION: (07) 32" Pilaster ORCO BLOCK COMPANY INC Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs ft ft-# HL Act Pres (ab water tbl) 31.0 0.44 13.7 HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = 583.9 6.33 3,698.1 Load @ Stem Above Soil = Total 614.9 O.T.M. = 3,711.9 Resisting/Overturning Ratio = 1.28 Vertical Loads used for Soil Pressure = 1,955.2 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Project File: beazer homes cantera__la quinta.ec6 (c) ENERCALC INC 1983-2022 Soil Over HL (ab. water tbl) Soil Over HL (bel, water tbl) Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth Q Stem Transitions = Footing Weight = Key Weight = .....RESISTING..... Force Distance Ibs ft 66.4 3.96 3.96 67.1 0.88 1,082.5 2.42 725.0 2.42 Moment ft-# 262.8 262.8 58.7 2,616.0 1,751.8 Vert. Component = 14.3 4.83 69.0 Total = 1,955.2 Ibs R.M.= 4,758.4 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.180 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. p�OFE55�ON w4�o d�R�uG � tirn rn m c� NO 83660 D * EXP 03/31/2025 sqr IV %\- F Of LAL'�O Project Title: Engineer: Project ID: Project Descr: Lo1e Footing Embedded in Soil LIC# : KW-06016003, Build:20.23.2.14 DESCRIPTION: (07) gate post footing Code References Calculations per IBC 2021 1807.3, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter ......... 18.0 in Calculate Min. Depth for Allowable Pressures Lateral Restraint at Ground Surface Allow Passive ................ 250.0 pcf Max Passive ................. 2,500.0 psf Controlling Values Governing Load Combinati®p+0.70E Lateral Load 2.726 k Moment 9.804 k-ft Restraint @ Ground Surface Pressure at Depth Actual 1,168.83 psf Allowable 1,218.75 psf Surface Retraint Force 6,999.54 Ibs Minimum Required Depth 4.875 ft Footing Base Area 1.767 ft^2 Maximum Soil Pressure 0.0 ksf ORCO BLOCK COMPANY INC Point Load Project File: beazer cantera pole calcs.ec6 (c) ENERCALC INC 1983-2022 Soil Surface ■10' • � D,tmret 6' 6 MMoment 42° n=AA7ft -1 Oft�387ft 6501b D Distributed Load 0 io Surface Latet!ral Restraint N 0 Applied Loads - Lateral Concentrated Load (k) Lateral Distributed Loads (kl _ Applied Moment (kft) Vertical Load (k) D : Dead Load 0.5420 k k/ft k-ft k Lr : Roof Live k k/ft k-ft k L : Live k k/ft k-ft k S : Snow k k/ft k-ft k W : Wind k 0.2670 k/ft k-ft k E : Earthquake k k/ft k-ft k H : Lateral Earth k k/ft k-ft k Load distance above TOP of Load above ground surface around surface 6.0 6.0 Lateral Dead Load was BOTTOM of Load above ground surface applied @6' height Load Combination Results Forces @ Ground Surface Load Combination Loads - (k) Moments - (ft-k) D Only 0.542 3.252 +D+0.60W 1.503 6.136 +D-0.60W 0.419 0.368 +D+0.450W 1.263 5.415 +D-0.450W 0.179 1.089 +0.60D+0.60W 1.286 4.835 +0.60D-0.60W 0.636 0.932 +D+0.70E 2.726 9.804 +D-0.70E 1.642 3.300 ft MMMen,= (6501b)(10ft/2) = 3.25 kips-ft DI-ateral Deed Lead = (3.25kips-ft / 6ft) = 0.542 kip ft WWindLead = 26.7psf (1 Oft) = 0.267 kips/ft ESelwic Lead = (0.80)(6501b) = O.524 Id ft Required Pressure at Depth Soil Increase Depth - (ft) Actual - (psf) Allow - (psf) Factor 3.38 808.9 843.8 1.000 4.13 1,021.7 1,031.3 1.000 1.63 395.3 406.3 1.000 4.00 958.9 1,000.0 1.000 2.38 547.2 593.8 1.000 3.88 912.3 96 Pe s s / o 1.000 2.25 521.8 4tio JADUCCNf oo 4.88 1,168.8 �� - 18.8 3.38 820.9 co m 84 140 m a o M I. N0. 83660 D * EXP- 03/31/2025 V rF 9F C A01094 Project Title: Engineer: Project ID: Project Descr: Pole Footing Embedded In Soil Project File: beazer cantera pole calcs.ec6 LIC# : KW.06016003. Build:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (07) gate post footing +D+0.5250E 2.180 8.166 4.63 1,081.6 1,156.3 1.000 +13-0.5250E 1.096 1.662 2.75 622.7 687.5 1.000 +0.60D+0.70E 2.509 8.503 4.63 1,126.3 1,156.3 1.000 +0.60D-0.70E 1.859 4.601 3.75 927.0 937.5 1.000 QpoFESS/nN S 0 N0, 83660 A EXP 03/31/2025 E OF c m-,F ORCO ENTRY MONUMENT PILASTER FOR //0 MPH EXPOSURE C WIND CONDI TI MM 1.90TE: DIMENSIONS ARE NOT TO SCALE. 32' (TOP SEGMENT) /—r rl PIGN CRITERIA PER THE 2022 CBC: I LLOWABLE SOIL BEARING PRESSURE = 2000 PSF + i INCR. FOR HIND/SEISMIC PER SOILS REPORT. QUIVALENT FLUID PRESSURE = 35 PCF PER SOILS REPORT. I LLOWABLE LATERAL PASSIVE PRESSURE = 250 PCF PER SOILS REPORT. GROUT STRENGTH = 2000 PSI @ 28 DAYS. !EINFORCING STEEL . GRADE 60 WONRY COMPRESSION STRENGTH, f ',,, = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. NORMAL WEIGHT. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITH A MAXIMUM OF 1-112 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE HIV. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 46 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOC4TED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 318" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-112"INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPEC17ON TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 11. PROVIDE EXPANSION/CONTROL JOINT EACH SIDE OF PILASTER WHEN INTERSECTING BLOCK WALLS OCCUR. ORCO 8816 CMU (TOP SEGMENT) AND 12816 CMU (BOTTOM SEGMENT) BLOCK CELLS TO BE SOLID GROUTED ONLY. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. #4 TIES 024' 0/C DETAIL # #4 VERT ® 16" 0/C AND BEAZER HOMES Q//e'� m 7 EA. CORNER GANTERA @a CORAL MOUNTAIN NO. 83660 D * EXP. 03/3//2025 T TRACT No. 31249 LA QUINTA, CALIFORNIA s�4 C 1 V TF OF cm_xF Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LTC# : KW•66016668, Buitd:26.03:2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (08) Entry monument pilaster Code Reference Calculations per IBC 2021 1807.3, ASCE 7-16 Criteria Soil Data Retained Height = 0.33 ft Allow Soil Bearing = 2,666.6 psf Wall height above soil = 6.67 ft Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Slope Behind Wall :• 0.00 Height of Soil over Toe 4.00 in = Water height over heel = 0.0 ft Passive Pressure = 166.7 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.400 Soil height to ignore for passive pressure = 12.00 in Surcharge Loads Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Lateral Load Applied to Stem Lateral Load = 868.6 #/ft ...Height to Top = 5.28 ft ...Height to Bottom = 4.28 ft Load Type = Seismic (E) (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Project File: beazer homes_cantera_la quin1a.ec6 (a) ENutdAw INC 1983.2022 Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Fig CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil at Back of Wall _ 0.0 ft - Poisson's Ratio - 0.300 .e%ofESS/pH yERDU fi w� w m N0. 83660 tF EXP. 03/31/2025 V Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall Project File: beazer homes_cantera_la quinta.ec6 LIC# : KW-06018603, Bulld:20.23.2.14 ORCO BLOCK COMPANY INC (c) ENERCALC INC 1983-2022 DESCRIPTION: (08) Entry monument pilaster Design Summary Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Stability Ratios Wall Material Above "Ht" - Masonry Overturning - 1.36 Ratio < 1.51 Design Method = ASD Sliding = 1.38 Ratio < 1.51 Thickness = 16.00 Global Stability = 5.25 Rebar Size = # 4 Rebar Spacing = 16.00 Total Bearing Load = 2,042 Ibs Rebar Placed at = 28 in ...resultant ecc. = 20.48 in Design Data Eccentricity outside middle third fb/FB + fa/Fa - 0.269 V , V Soil Pressure @ Toe = 2,156 psf OK Total Force @ Section Soil Pressure @ Heel = 0 psf OK Service Level Ibs = 609.9 ,In Allowable 2,667 psf Strength Level Ibs = Soil Pressure Less Than Allowable Moment.... Actual ACI Factored @ Toe = 3,018 psf Service Level ft-# = 2,904.E 0 ACI Factored @ Heel = 0 psf Strength Level ft # _ Footing Shear @ Toe = 20.0 psi OK Moment..... Allowable = 10,778.3 Footing Shear @ Heel = 3.3 psi OK Allowable = 75.0 psi Shear..... Actual Service Level psi = 3.3 Sliding Calcs Strength Level psi = Lateral Sliding Force = 639.0 Ibs Shear..... Allowable psi = 52.2 less 100% Passive Force 64.8 Ibs Anet (Masonry) in2 = 187.50 less 100% Friction Force s - 816.8 Ibs Wall Weight psf = 171.5 Added Force Req'd = 0.0 Ibs OK Rebar Depth 'd' in = 28.00 ....for 1.5 Stability = 76.8 Ibs NG Masonry Data Vertical component of active lateral soil pressure IS f'm psi = 2,000 considered in the calculation of soil bearing pressures. Fs psi = 32,000 Solid Grouting = Yes Load Factors Modular Ratio 'n' = 16.11 Building Code Equiv. Solid Thick. in = 15.63 Dead Load 1.200 Masonry Block Type = Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data _ Wind, W 1.000 fc psi = Seismic, E 1.000 Fy psi = ASD Q9,0FESS/041 4wo ov,Db ti c � 47 t71 m NO 83660 * EXP. 03/31/2025 sT4r C I V � p� CAS �Ffl Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall I IG# : KW06016003, 6uIId:20.23.2.14 DESCRIPTION: (08) Entry monument pilaster Footing Data Toe Width = 1.67 ft Heel Width = 3.00 Total Footing Width = 4.67 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in ORCO BLOCK COMPANY INC Footing Design Results Project File: beazer homes_cantera_la quinta.ec6 (c) ENERCALC INC 1983-2022 Toe Heel Toe: phiMn = ph'5'lambda'sgrt(fc)`Sm Heel: phiMn = ph'5"lambda`sgrt(fc)'Sm Key: No key defined 00 ft-Ibs 00 ft-Ibs Min footing T&S reinf Area 1.21 in2 Min footing T&S reinf Area per foot 0.26 in2 M If one la er of horizontal bars: II two lavers of horizontal bars: #4@ 9.26 in #4@ 18.52 in� #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in �p.OFESS/ON �SRptJ F cl NO. 83660 * EXP.. 03/31/2025 * . V,L ¢v OP C41.\Io Project Title: Engineer: Project ID: Project Descr: Cantilevered Retaining Wall LIC# : KW-06016003, Build:20.23.2.14 ORCO BLOCK COMPANY INC DESCRIPTION: (08) Entry monument pilaster Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... M Force Distance oment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 31.0 0.44 608.0 5.78 13.7 3,512.4 Total _ 639.0 O.T.M. = 3,526.1 Resisting/OverturnIng Ratio = 1.36 Vertical Loads used for Soil Pressure = 2,042.0 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Project File: beazer homes _cantera_la quinta.ec6 (c) ENERCALC INC 19B3.2022 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 63.3 3.83 242.5 Soil Over HL (bel. water tbl) 3.83 242.5 Water Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = 63.9 0.83 53.3 Surcharge Over Toe = Stem Weight(s) = 1,200.5 2.33 2,801.6 Earth Q Stem Transitions = Footing Weight = 700.1 2.33 1,633.6 Key Weight = Vert. Component = 14.3 4.67 66.7 Total = 2,042.0 Ibs R.M.= 4,797.5 • Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 150.0 pci Horizontal Defl Q Top of Wall (approximate only) 0.150 in The above calculation is not valid if ilia heel still bearing ressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. 4Rof Ess f 04, ewa 4ffZDU rn M w ��m x NO.03660 * EXP. 0V3112025 srgr CIVIV ¢� p F Or cA0