0010-125 (SFD) Title 24r
TITLE 24
Energy Conservation
Standards Compliance Report
ESTANCIAS CUSTOM RESIDENCE
LOT 14 - ESTANCIAS - LA QUINTA
June 26, 2000 v Job .Number: 19520A
�O Lr Z45' Prepared For.; -
WALLING & MCCALLUM LTD.
DR -
C1 OF LA Q U i �iTA 45-190 CLUB DR
INDIAN WELLS, CA 92210
BUILDING & SAFETY DEPT.
APPROVE®
FOR CONSTRUCTION
DATE t3 BY
Maalin's
enterprises
vvvvvvv
Catherine M. Madlin, Certifced Enemy Analyst
Post Office Bax 1443 v Palm Springs, CA 92263
760-322-5004 / 323-3:644 (fax)
E-mail: CMadlin@aol.com
01
Maaiin s
enterprses
Catherine M. MadW; Cern gyred Emry Analyst' :760-322-50041323-3644 (fax) V ... v ..
Title 24 Energy Conservation Standards
Compliance Report
This proposed project has been reviewed for compliance with the 1998 State of California
Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design
described in this compliance portfolio is in conformance with, the standards as outlined in
the attached compliance forms and documentation.
Date: June 26, 2000
Job Number: 19520A
Prepared For: WALLING & McCALLUM. LTD.
Project Name: ESTANCIAS CUSTOM RESIDENCE
Project Location: LOT 14 - ESTANCIAS - LA QUINTA
Method of Compliance: AIICROPAS V5.1 CERTIFIED COMPUTER PROGRAM
Orientation Of Entry: EAST
Certified Energy Analyst
Catherine M. Madin
NR 98-90-544
r r
C R 98-90-144
C. A d E C
":'iQ Association of Building Energy C_onsuironts
• Post Office Box 1443 v Palm Springs, Ca 92263
i
o J
Maattn s
erste rises
Catherine M: 1lMaAt; Certified Energy. Analyst v 760-322-50041323 360 "1") . V S . v ..
Job Name
ESTANCIAS CUSTOM RESIDENCE
Job No../ File No.
19520A
Method ofCompliance
Micropas V5 Computer Simulation
Total Conditioned Square Footage
5080 Sq. Ft.
Total Glazing % (Floor/Glass Area Ratio)
22.1'0/6
Insulation: ;Roof / Ceiling
R-38
Insulation: Walls
R-21
Insulation: 'Floor - Raised
n/a
Insulation: Floor. - Slab on Grade
None Required
Insulation: H.VA.C. Ducts/Location
R-4.2 / Attic
Glazing U Value / Type: Operable
0.54, Dual, .Alum. Frame, Low E
Glazing U -Value ,/ Type- Fixed
0.50, Dual, Alum. Frame, Low E
Glazing U' -Value / Type: Patio
0.54, Dual, Alum, Frame, Low E
Glazing U=Value / Type: Glass Block
0.57 (CBC Default Value)
Glazing U -Value / Type: Skylights
0.94 Dual Domed (CBC Default Value)
Glazing: Solar Heat Gain Coefficient (Uncoated).
0.57 Tinted, Glazing
Glazing. Exterior Shading'
Overhangs As Shown
Glazing. Interior Shading
Blinds (Light Colored) - Most Windows
Thermal Mass Square Footage & %
None. Required
H.V.A.C. System Type
Gas Heating / Electric Cooling
HVAC System Efficiencies (heating/cooling)
78% AFUE / 112.0 SEER
Domestic Hot Water Heater
(2) 75Gal. Gas
Energy Factor / ME / Standby Loss
0.77 Recovery effideney or better
R12 Blanket on Tank
Yes
II Recirculating. Pump for DHW I Recirculating,with time and temp. controls II
v Post Office Bax 1443 • Palm Springs, Ca 92263 v
M, ad
enterprises
Catherine M. Ma&A Certified Energy Analyst • 760-322-5004..1323-3644 (fax) ` v v v v v v
Title 24 Compliance Forms
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
------------------------
ProJect Address........ LOT 14 ESTANCIAS
Project Title.......... WALLING.:LOTI4.ESTANCIAS' Date..06/2,6/00 09:58:23
LA .QUIN.TA *v5.10*
Documentation.Author... CATHERINE M. MADLIN ******* ul-.ding Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check / DatU
Palm Springs, CA 92262
760-322-5004 Mid check/Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPASS v5.10 for 19'98 Standards by Enercomp, Inc.
---------------------- -------- -- -------------------------------
--------------------- --- -------------------------------
MICROPAS5. v5.10 File=1952OA3 Wth-CTZ15S9.2 Program -FORM CF -1R
I User#-MP0.207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
GENERAL INFORMATION
= ------------------
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories.. ....
Floor Construction Type...,
Glazing Percentage.........
.Average Glazing U -value....
Average Glazing SHGC.......
Average,Ceiling Height.....
5080 sf
Single Family Detached
New
Front Facing 9.0 deg (E)
1
1
Slab On Grade
22.1 % of floor area
0.53 Btu/hr-sf-F
0.5'7
12.3 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing Total Assembly
Type
Type
R -value
R -value R -value U -value
Location/Comments
------------
Wall
Wood--
-R------
-R------
-R----- --0 088
------------------------
Door
None
R-0
R-0
R-0 0.330
Roof.
Wood
R-11
R-27
R-38 0..025
5labEdge
None
R-0
R-0
F2=0.760
S1abEdge
None
R-0
R-0
F2=0.510
FENESTRATION
-------------
Over-
Area
U-
Interior
Exterior
hang/
Orientation
(sf)
-----
Value
SHGC Shading
Shading
Fins
Door
Left SW)
48..0
------
0.540
---------------------
0.570 Blind
--------------
Standard
-----
Yes
Window
Left SW)
9.5
0.500
0.570 Blind
Standard
Yes
Window
Back W
6.0
0.500
0.570 Blind
Standard
Yes
Door
Back W)
48.0
0.540
0.570 Blind
Standard
Yes
Window
Back NW
lw�
9..5
0.500
0.570
Standard
Yes
Door.
Back. NNW`)
48.0
0.540
,Blind
0.570 .Blind
Standard.
Yes
Window
Back W25.0
6.540
0.570 Blind
Standard
Yes
Window
Back W
14.0
0.500
0.57.0 Blind
Standard
'Yes
Window
Back
12.8
0.500
0.570 Blind
Standard.
Yes
CERTIF,ICA.TE OY COMPLI'ANCE: RESIDENTIAL Page 2 CF -1R
--------------------------------------------------
Project Title........... WALLING.LOTI4.ESTANCIAS Date..06/26/0.0 09:58:.23
------------------------------ ---------------- ----___-___ _________________
MICROPAS5 x5.10 I File-1952OA3 Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
FENESTRATION
Over -
standard Slab 5.080
Area
U-
Interior
'Exterior
hang/
Orientation
(sf)
Value
SHGC
Shading
Shading
Fins
Door
Front
E
51.0
0..540
0.57G
Blind
Standard -
Yes
Window
Back
W
14.0
0.500
0.570
Blind
Standard
Yes
Window
Back
W
1
12.8
0.500
0.57'0
Blind
Standard
Yes
Door
Back
W
51.0
0.540
0.570
Blind
Standard
Yes
Window
Left
$
40.5
0.500
0.570
Blind
Standard
Yes
Window
.Back
W
14.0
0.500
0.570
Blind
standard
Yes
Window
Back
W
21.0
01.500,
0..570
Blind.
Standard
Yes
Door
Back
W
54.6
0.54.0
0.:570
Blind
Standard
Yes
Window
Back
W
14.0
0..500
0,.5`70
Blind
Standard
Yes
Window
Back
W
21.0
0..500
0.570
Blind
Standard
Yes
Door
Back
W
��64.0
0.510
0.570
Blind
Standard
Yes
Window
Back
W--14.0
0..500
0:570
Blind
Standard
Yes
Window
Back
W
-=- 2:1.:0
01. 500
0.570
Blind
Standard
Yes
Door
Back
W
54,.0
0,.540
0.570
Blind
Standard
Yes
Door
Back.
W
64.0
0.540
0.570
Blind
Standard
Yes
Window
Back
W
16.0
0..570
0.670
Standard
Standard
Yes
Door
Left
S
64.0
0.546
0.570
Blind
Standard
Yes
Window
Back
W
49.5
6.500
0.570
Blind
Standard
Yes
Window
Right
N
39..0
0,.500
0.570
Blind
Standard
Yes
Window
Right
;N'
5.0
0.570
0.670
Blind
Standard
Yes
Window
Right
N
7..5
0.570
0.670
Standard
Standard
Yes
Door
Front
E
=, 64.0
0.540
0..570
Blind
Standard
Yes
Door
Front
E
64.Q
6.540
0.570
Blind
Standard.
Yes
Window
Front
E
7.-5
0.570
0.670
Standard
Standard
Yes
Window
Front
`E
8..0
0.570
0.670
Blind
Standard.
Yes
Door
Front
`E
64.0
0.540
0.576
Blind
Standard
Yes
Skylight
Horz
1.0
0.940
0.760
None
None
None
Skylight
Horz
4.0
0.940
0.766
None
None
None
SLAB SURFACES
-------------
Area
Slab Type
(sf)
standard Slab 5.080
CERTIFICATE. OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title ........ ... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58:23
------------------------------------------------------------------------------
MICROPAS5 x5.10 File-1.9.52OA3 Wth=CTZ15S92 Program -FORM CF -1R
I User#-MP0,207 User-Madlin's Enterprises Run -PERMIT CALCULATION
HVAC SYSTEMS
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated 'Loss Insulation Pilot
System Efficiency Input Fraction R -value Light
------------ ------------ --------------------------------
Large 0:77 n/a 0.03 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
** Items in this section should be documented on the plans, ***
*** installed to manufacturer' and CEC specifications, and ***
***verified during 'plan check and field inspection. ***
This building incorporates non-standard Water' Heating System
REMARKS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
conservation Standards. The owner may (at. his/her option) install
better materials without additional compliance calculations.
The installing hvac Contractor shall provide the required CF -6R
with the installed hvac equipment model numbers.
A night setback, thermostat is required to be installed with the
HVAC system.
The installed plumber shall provide the required CF -6R listing
the water heater model number(s.) andcertified plumbing
fixtures.
Minimum Duct
Duct Tested Duct ACCA
Thermostat
Equipment Type
Efficiency Location
R -value
Leakage
Manual
D Type
Furnace:
--
0.780 AFUE Attic
-- -----------
R-4.2
No
---------
No
-
Setback.
ACSplit
12.00 SEER Attic
R-4.2
No
No
Setback
WATER HEATING
SYSTEMS
---------------
Number
Tank
External
in
Energy
Size
Insulation
Tank Type Heater Type Distribution Type System
Factor
(gal)
R -value
Large Gas
Recirc/TimeTemp
2
n/a
75
R-12
WATER HEATING SYSTEMS DETAIL
Standby Internal Tank
Recovery Rated 'Loss Insulation Pilot
System Efficiency Input Fraction R -value Light
------------ ------------ --------------------------------
Large 0:77 n/a 0.03 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
** Items in this section should be documented on the plans, ***
*** installed to manufacturer' and CEC specifications, and ***
***verified during 'plan check and field inspection. ***
This building incorporates non-standard Water' Heating System
REMARKS
The values and materials used in this compliance portfolio are
the minimum required to show compliance with Title 24 Energy
conservation Standards. The owner may (at. his/her option) install
better materials without additional compliance calculations.
The installing hvac Contractor shall provide the required CF -6R
with the installed hvac equipment model numbers.
A night setback, thermostat is required to be installed with the
HVAC system.
The installed plumber shall provide the required CF -6R listing
the water heater model number(s.) andcertified plumbing
fixtures.
CERTIFICATE OF' COMPLIANCE: RESIDENTIAL Page 4 CF -1R
Project Title.......... WALLING.LOTI4.ESTANCIAS Date 06/26./00 09:58:23
--- --------------------------------------------------
1 MI,CROPASS v5.10 File-1952OA3 Wth-CTZ15;S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
REMARKS
,COMPLIANCE STATEMENT
--------------------
This certificate ofcompliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations,.and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to.be built in multiple orientations,
any shading feature that s varied is indicated in the Special Features
M.i
Modeling Assumptions section.
Name....
Title,.. .
Agency..
Phone....
Signed —
a e,
Ce-rtified Energy Analyst
Catherine M. Madlin
NR 98-90.544
r r R 98-90-144
r
CADEC
Association of building Energy Consultants
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name....
JOHN WALLING
Name....
CATHERINE M. MADLIN
Company.
WALLfiNG & McCALLUM LTD
'Company.
Madlin's'Enterprises
Address.
45-190 CLUB DRIVE
Address.
P.O. Box 1443
INDIAN WELLS, CA 92210
Palm Springs, CA 9226.2
Phone...
760-36:0-02,50
Phone...
760-322-5004
License.
Signed..
'-
Signed.,
a e
,e�
Zoo
ENFORCEMENT AGENCY
Name....
Title,.. .
Agency..
Phone....
Signed —
a e,
Ce-rtified Energy Analyst
Catherine M. Madlin
NR 98-90.544
r r R 98-90-144
r
CADEC
Association of building Energy Consultants
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page l MF -1R
Project Title....-.... WALLING.:LOTI4.ESTANCIAS, Date..06/26/00 09:58:23
Project Address........ LOT 14 ESTANCIAS ******* ---------------------
LA QUINTA *x5.10*
Documentation Author... CATHERINE M. MADLIN HuTlutng ermi
Madlin's Enterprises'
P.O.. Box 144.3 Pian uneck / DatE
Palm Springs, CA 92262
760-3'2.-5004 le ec a e
Climate Zone.. .........15 ----------------------
Compliance.Method....... MICROPAS5 v5.10 for 1998 Standards by Enercomp., Inc.
----------- --------__ ___ -----------
MICROPAS5 v5.10 File -19520A3 Wth-CTZ15S`92 Program -FORM MF -:1-R
User#-MP020'7 User-Madlin.'s Enterprises Run -PERMIT CALCULATION I
Note: Lowrise residential buildinggs subject to the Standards must. contain these
,measures regardless of' the compliance approach used. Items. marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted. shall be considered by all parties as
minimum component performance specifications for the: mandatory' measures whether
they are shown elsewhere in the documents or on this checklist only.
BUI-LD.ING ENVELOPE MEASURES
Design- ,Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation,,
156 1 b Loose fill insulation ma_nufacturer''s labeled R -Value.
*150 c Minimum R-13 wall insulation in wood framed walls�or
equivalent U -value in metal frame wal;ls,(does not apply
to -exterior mass walls).
*150 d : MinimumggR-13 raised floor insulation in framed floors.
15than•Us3 b water lyauorttr'ansmwster absorption rate no greater
(� ��
, p transmission, rate no greater than 2.0
perm/inch.
1.18: Insulation specified or installed meets CEC quality
standards. Indicate type. and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
exfil.tration controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label_ with certified U -value, certified solar Meat gain.
coefficient, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and' sealed.,
150(.g) Vapor barriers mandatory in Climate Zones 14 and. 1.6
onlly.
150(f'): Special infiltration barrier installed to comply with
Sec. 151 -meets Commission quality standards..
150(e)•, Installation of Fireplaces, Decorative Gas Appliances
and.Gas Logs
i. Masonry and factory -built fireplaces have:
MANDATORY MEASURES CHECKLIST:, RESIDENTIAL Page 2 MF -1R
-------------------------------------------------------------------------------
Project Title.......... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58:23
--------------------------------------------------------
MICROPAS5 v5.10 File -19.520A3 Wth-CTZ15S-92 Program -FORM MF -1R
I User#-MP0.2,07 User-Madlin's Enterprises Run -PERMIT CALCULATION I
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed:.
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
----------------------=---------------------------------------
Design- 'Enforce-
er merit
110-113: HVAC eguipment,'water. heaters, showerheads and.
.faucets certified by the Commission..
150(h): Heating and/or cooling loads calculated in accordance
with,ASHRAE, SMACNA or ACCA,.
150(i): Setback thermostat on all applicable: heating and/or
coolingsystems.
150(j): Pipe and Tank insulation
1.. Storage gas water heaters rated with an Energgyy Factor of
less than 0.58 must be externally wrapped wig insulation
having an installed thermal resistance of R-1:2 or greater.
2. First 5 feet of pipes closest to 'water heater tank., non -
recirculating systems, insulated (R-4 or greater.).
3. Back-up tanks for solar systems, unfired storage tanks, or
other indirect hot water, tanks have R=12 external
insulation or R-16 combined internal./external insulation.
4. All buried or exposed piping insulated in recirculating
sections of hot water system..
5: Cooling system piping below 55 degrees insulated.,
6. Pipping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. All ducts and plenums constructed, installed, in-
sulated, fastened, and sealed to comply with the ICBG
1997 UMC sections 601 and 603; ducts insulated to a
minimum installed R-4.2 or ducts enclosed entirelyy
within conditioned space: Openings shall be sealed
with mastic, to e,_aerosol sealant or other duct closure
system that meets the appppl-icable requirements of UL181,
UL181A, or UL181B and other applicable specified tests
for longevity given in Sec. 150(m).
2. Exhaust fan systems have backdraf. or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic -or readily accessible, manually
operated dampers..
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78* thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:.
a. At least 36 inches ofpipe between filter and heater
for future solar heating.
MANDATORY MEASURES CHECKLIST': RESIDENTIAL 'Page.3 MF -1R,
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project .Title.......... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58:23
-------------------------------------------------------------------------------
MICROPAS5 I x5.10 File-1.952OA3 Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madl_in's Enterprises Run -PERMIT CALCULATION I
b. Cover for outdoor ppools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas -:fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
Pilot, light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr).
LIGHTING MEASURES
-----------------
Design- Enforce-
er men
150(k)l: Luminaires for general lighting in kitchens shall
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general lighting
shall be controlled by a switch on a readily accessible.
li,ghting'control panel at an.entrance to the kitchen.
,150(k)2: Rooms with a shower or bathtub must either have at
least one luminaire with. lamps with an efficacy of 40
lumens/watt or greater switched at the entrance to the
room or oneof the alternatives to this requirement
allowed in Sec. 1.50(k)2.; and recessed ceiling fixtures
are IC (insulation cover.) approved.
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... WALLING.LOTI4..ESTANCIAS Date..06/2'6/00 09.5.8:23
Project Address........ LOT 14 ESTANCIAS ******* ---------------------
LA QUINTA *v5.10*
Documentation. Author... CATHERINE M. MADLIN ******* uT ing Permit
MadlinIs Enterprises
P..O. Box 1443 Pian Cneck / vatE
Palm Springs, CA 9226.2
760-322-5004 Fleid checx,/Date
Climate,Zone............ 15 ---------------------
Compliance Method....... MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
------------------------------------------- -- ----------- -- - -------=---
MI.CROPAS5 x5.1.0 File -19520A3 Wth-CTZ15S92 I Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
- - ---- --
= MICROPAS5
------------------------------------
ENERGY USE
SUMMARY----------------------------
=
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
Design
Design
Margin =
= Space Heating..........
4.06
4.03
0.03 =
_ Space Cooling..,........
39.33
39.8b
-0.53 -
_ Water Heating...........
5.61
4.81
0.80 =
Total 49.00 48.70 0.30 =
*** Building complies with Computer Performance
GENERAL INFORMATION
Conditioned Floor Area...... 5.080 sf
Building Type.............. Single Family Detached
Construction Type......... New
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units:... 1
.Number ofBuilding Stories.. 1
Weather Data Type.......... Fullgear.
Floor Construction Type.... slab On Grade
Number of Building zones... 1
Conditioned Volume.......... 62266 cf
Slab -On -Grade. Area......... 5080 sf
.Glazing Percentage.......... 22.1 % of floor area
Average Glazing U -value.... 0.53 Btu/hr-sf-F
Average Glazing SHGC...... A 0.57
Average Ceiling Height..... 12.3 ft
COMPUTER METHOD SUMMARY Page 2 C -2R
-----------------------------------------------------------------------------
`Project Title.......... WALLING..LOT14..ESTAN.CIAS Date..06/2:6/00 09:584. 23
---------------------------------------------------------
` MICROPAS5 x5.10 File-1.952OA3 Wth-CTZ15G92 Program -FORM C -2R
I User#-MP0207 User-MAdlin's Enterprises Run -PERMIT CALCULATION I
--------------------------------------=----------------------------------------
Zone Type
-------------
HOUSE
Residence
Surface
HOUSE
1
Wall
2
Wall
3
Wall
4
Wall
5
Wall
6
Wall
7
Wall
8
Wall
9
Door
10
Door
11
Door
12
Roof
.Surface
------------
HOUSE
13 SlabEdge
14 SlabEdge
Orientation
HOUSE
Length F2 Insul Solar
(f't°) Factor R-val Gains Location/Comments
405 0.760 R-0 No
52 0.51.0 R-0 No
1
BUILDING ZONE
INFORMATION
SM"
Floor
Window
--------------------
#of
SW
3
----
Vent
Vent Air
Area
Volume
Dwell
Units
Cond.-
itioned
Thermostat Height
Type
Area Leakage
(sf)
( cf )
Blind 0.47
6
Door
(ft)
(sf) Credit
5080
62266
1.00
Yes
Setback 2.0
Standard No
25.0'0.,540
0.570 270
OPAQUE SURFACES
Blind 0.47
Area
U-
---------------
Insul
Act
Solar
Form 3
Location/
(sf)
value
R-val
Azm Tilt
Gains
Reference
Comments
1.015
0..088
1.3
90
9D Yes
W'.13.2X4.16
57.4
0.088
1.3
.180
90 Yes
W.13.2X4.16
736
0.0188
13
270
90 Yes
W.1.3.2X4.16
755
0.0.88
1,3
0
90 Yes
W.1.3.2X4.16
540
0.088
13
90
90 No
W.13.2X4.16
:57
0.088
13
225
90 Yes
W.13.2X4.16'
57
0.088
13
315
90 Yes
W.13.2X4.16
35
0.088
13
45
90 Yes
W.,13..2X4.16
60
0.330
0
180
90 Yes
None
21
0.330
0
0
90 Yes
None
40
0.330
0
90
90 No.
None
5077
G.02'5
38
n/a
0 Yes
R.38..2X4.24
PERIMETER
----------------
LOSSES
.Surface
------------
HOUSE
13 SlabEdge
14 SlabEdge
Orientation
HOUSE
Length F2 Insul Solar
(f't°) Factor R-val Gains Location/Comments
405 0.760 R-0 No
52 0.51.0 R-0 No
1
Door
Left
SM"
2
Window
Left.
SW
3
Window
Back.
W
IM
4
Door
Back
W;
5
Window
Back
Blind 0.47
6
Door
Back
7
Window
-Back
W`)
FENESTRATION SURFACES
---------------------
Area U- Act Exterior Shade Interior Shade
(sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC
--- ---- -------------- --------------
48. eO. 5'40
-------------
48.0.540
0.570 225
90
Standard/0.76
Blind/0.47
9.5 0.500
0.510 225
90
Standard/0.76
Blind/0.47
6. 00.500
0.570 270
90
Standard/0.76
Blind%0..47
48.0'O.540
0.570 270
90
Standard/0.76
Blind 0.47
9.-,g 0.,,500
0.57.0 31.5
90
Standard/0.7'6
Blind/0.47
48..0'0..:540
0.570 31.5
90
Standard/0.76
Blind 0.47
25.0'0.,540
0.570 270
90Standard/0.76
Blind 0.47
COMPUTER.METHOD SUMMARY Page 3 C -2R
-------------------------------------------------------------------------------
Project Title.......... WALLING.LOTI4..ESTANCIAS Date..06/26/00. 09:58:23
--------------------------- ----- --- -----------------________�_--_---
MICROPAS5 v5.10 File -19520A3 Wth-CTZ15S92 Program -FORM C -2R
I User#-MP0207 'User-Madlin's Enterprises Run -PERMIT CALCULATION I
Surface
HOUSE
8 Window
9 Window
10 Door
11 Window
12 Window
13 Door
14 Window
Interior Shade
Type/SHGC
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Blind 0.47
Blind 0.47
Blind 0.47
Blind/0.47
Blind/0.47
Blind/0,47
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Blind/'0.47
Blind/0.47
Standard/0.68-
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Standard/o.68
Blind/0.47
Blind/0.47
Standard/0.68
Blind/0.4'7
Blind/0..47
None/1.
None/1.
-Window-- ------Overhang --=- ---Left Fin--- ---Right Fin--
Area Left Rght
(sf) Wdth. Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght,
14.0
6
3
2
FENES:TRATION'SURFACES
n/a
n/a
n/a
n/a
---------------------
Area U-
n/a
Act
n/a.
Exterior Shade
Orientation
2.25
2
(sf.) Value
SHGC
Azm
Tilt
Type/SHGC
8
Window
Back
W
14.0 0.5,G0
0.570
2'70
90
Standar /0,76
9
Window
Back
W
n/a
1.2.8'0 50:0
0.570.
2'70
90
Standard/0.76
10
Door
Front
E
51.0'0.540
0.570
108
90
Standard/0.7.6
11
Window
Back
;W
2
14..0 0.5:00
0.,570'
270
90
Standard/0.76
12
Window
Back
W
51.0
12.8' 0.5'00
0.5'70
270
90
Standar /0.7'6
1.3
Door
Back
W
n/a
51.00.540
0..570
210
90
Standar /0.76
1.4
Window
Left
S
n/a
40.5-0.5.00
0.570
1,80
9:0
Standard/0.76
15
Window
Back
W
14.0 0.500
0.570
270
90
Standard/0.76
1.6
Window
Back
W
21.0'0.500
0.570
270
96
Standard/,0.76
17
Door
Back
W
54.040.540
0.570
270
90
Standard/0.:76
18
Window
Back
W
14.0'0.50,6
0.570
270
9�0
Standard/0.76
19
Window
Back
W'
2.1.0'0.500
0.570
270
90
Standard/0.76
20
Door
Back
W
64.,6-0.54:0
0..570
270
90
Standar /6.76
21
Window
Back
W
14.0"0.500
0.576
270
90
Standard/0.76
22
Window
Back
W
21,.0.0..500
0.570
270
90
Standard/0.76
2.3
Door
Back
W
54.0.0.540
0,570
270
90
Standard/0.76
24
Door
Back
W
64.0-0.540
0.570
210
90
Standard/0.76
2��5
Window
Back.
W
1,6.0-0.570
0.670
270
90
Standard/0.7"6
26
Door
Left
S
6'4.00.540
0.570
180
9.0
Standard/0.76
27
Window
Back
W
49.5,0.500
0.570
270
90
Standard/0.76
28
Window
Right
N
39.0 0.500
0.570
0
9'0
Standard/0.76
29
Window
Right
N
5.0 0.570
0.670
0
90
Standar /0.76
30
Window
Right
N
7.kf 9.570
0.670
0
90
Standard/0.76
31
Door
Front
E
64. 0.540
0.570
90
90
Standard/0.76
32
Door
Front
E
64..0'0.540
0.570
.96
90
Standar /0-76
33
Window
Front,
E
7.5 0.5`70
0.610
90
90
9tandard/0.76
34
35
Window
Door
Front.
E
8.jV- 0.570
0.670,
9'0
90
Standard/0.76
Front
E
64.x0..540
0.570
90
90
Standard/0.76'
36
Skylight
Horz
1..0 0.,940
0.760
90
0
N6ne/1
37
Skylight,
Horz
4.0 0.940
0.760
90
0
None/1
OVERHANGS AND SIDE FINS
-----------------------
Surface
HOUSE
8 Window
9 Window
10 Door
11 Window
12 Window
13 Door
14 Window
Interior Shade
Type/SHGC
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Blind 0.47
Blind 0.47
Blind 0.47
Blind/0.47
Blind/0.47
Blind/0,47
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Blind/'0.47
Blind/0.47
Standard/0.68-
Blind/0.47
Blind/0.47
Blind/0.47
Blind/0.47
Standard/o.68
Blind/0.47
Blind/0.47
Standard/0.68
Blind/0.4'7
Blind/0..47
None/1.
None/1.
-Window-- ------Overhang --=- ---Left Fin--- ---Right Fin--
Area Left Rght
(sf) Wdth. Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght,
14.0
6
3
2
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a.
n/a.
12.8
5.67
2.25
2
3
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
51.0
5.67
9
2
5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
,14.0
6
3
2
0
n/an/a
n/a
n/a
n/a
n/a
n/a
n/a
12-8
5.67
2.25
2
3
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/A
51.0
5.6.7
9
2
5
n/a ,
n/a
n/a.
n/a
n/a
n/a
n/a
n/a
40.5
4.5
9,
2
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
COMPUTER METHOD SUMMARY Page 4 C -2R
Project Title.......... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58:23
----------- --- ---------------------
MICROPAS5 v5.10 File 1,95.2.OA3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP0201 User-Madlin.';s Enterprises Run -PERMIT CALCULATION I
OVERHANGS AND SIDE FINS
SLAB SURFACES
Area
Slab Type (sf)
HOUSE
Standard Slab 5080
HVAC SYSTEMS.
------------
.Minimum Duct Duct Tested Duct ACCA Duct
System Type Efficiency Location R -value Leakage Manual D Eff
HOUSE
Furnace 0.7`80 AFUE Attic R-4.2 No No 0.74.3
ACSplit 12.00 SEER Attic R-4.2 No No 0.596
---Window--
------ Overhang
--
---Left Fin---
---Right
Fin -
Area
Left
Rght
Surface
(sf)
Wdth
Hgth
Dpth
Hght
Ext
Ext
Ext
Dpth
Hght.Ext
Dpth
Hght
15
Window
14.0
6
3
2.5
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
16
Window
21.0
6
3.5
2.5
3
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
17
Door
54.0
6
9
2.5,
6..5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
18
Window
14.0
6
3
2.5
0
n/a,
n/a
n/a
n/a
n/a
n/a
n/a
n/a
1.9
Window
21.0
6
3.5
2.5
3
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
20
Door
64.0
6
9
2.5
6.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
21
Window
14.0
6
3
2.5
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
22
Window
21.0
6
3.5
.2.5
3
n/a
n/a
n/a
n/a,
n/a
n/a
n/a
n/a
23
Door
54.0
6
9
2.5
6.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
24
Door
6.4.0
8
8
9
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
25
Window
16.0
2
8
9
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
26
Door
64.0
8
8
24
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
28
Window
39.0
6
6.5
3
0
n/a
n./a
n/a
n/a
n/a
n/a
n/a
n/a.
29
Window
5.0
1
5
3
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
31
Door
64.0
8
8
2.5
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a.
32
Door
64.0
8
8
2.5'
0
n/a
n/a
n/a,
n/a
n/a
n/a
n/a
n/a,
34
Window
8..0
1
8
B.
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
3.5
Door
64.0
8
8
2
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a.
SLAB SURFACES
Area
Slab Type (sf)
HOUSE
Standard Slab 5080
HVAC SYSTEMS.
------------
.Minimum Duct Duct Tested Duct ACCA Duct
System Type Efficiency Location R -value Leakage Manual D Eff
HOUSE
Furnace 0.7`80 AFUE Attic R-4.2 No No 0.74.3
ACSplit 12.00 SEER Attic R-4.2 No No 0.596
COMPUTER METHOD SUMMARY Page 5 C -2R
Project Title. ....... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58 2.3
-------------------------------------------------------------------------------
MICROPA S5 v5.10 File -19520A3 Wth-CTZ15S92 Program -FORM C -2R
User#-MP02.07 User-Madlin's Enterprises Run -PERMIT CALCULATION I
WATER HEATING SYSTEMS
------------
Number Tank External
in Energy Size Insulation
Tank -Type ,Heater Type Distribution Type System Factor (gal) R -value
-- ----------- ------------------ -------------- ------ ----------
1 Large Gas Recirc/TimeTemp 2 n/a 75 R-12
WATER HEATING SYSTEMS DETAIL
------ ----
Standby Internal Tank
Recovery .Rated Loss Insulation Pilot
System Efficiency Input Fraction R -value Light
- --- --------- --------------- -------
1 Large 0.77 n/a 0.03 R-n/a 0
SPECIAL FEATURES AND MODELING ASSUMPTIONS
------------------------------------------ ' ***
*** 'Items in, this section should be documented on the plans,
*** installed to manufacturer and CEC specifications, and ***
** verified during plan check and field inspection. ***
This building incorporates non-standard Water Heating System
The values and. materials, used in this compliance portfolio are
the: minimum required to show compliance with Title 24 Energy
Conservation Standards. The owner may (at his/her option) install
better materialswithout additional compliance calculations.41.
The installing hvac contractor shall provide the required CF -6R
with the installed hvac equipment model numbers.
A night setback' thermostat is required to be installed with the
HVAC system.
The ;installed plumber shall provide the required CF -6R listing
the water heater model numbers) and certified plumbing
fixtures.
CONSTRUCTION ASSEMBLY Page 1 3R
Project Title............ WALLING.LOT1.4..ESTANCIAS Date=..06 26 00 09:5,8i.23
------------------------ -------------------------
-------------------- --------------------------
I-MICROPAS5-v5.10 File-1952OA3 Wth-CTZ15S92 Program -FORM 3R 1
l User#-MP0207 User-Madlin's Enterprises Run PERMIT CALCULATION I
-------------------------------=- Parallel Path.Method
Reference Name . W.13.2X4.16
Description ....'Wall R-13 2x4 16oc
Type ........... Wall
R -Value 1.3 Hr.-sf-F/Btu
Framing
Material .....
Type ..
Description ..
spacing .
Framing Frac..
---------------------------------
Sketch of Construction Assembly
FIR.. 2X4
Wood
2x4 fir
16 inches on center
0.:15
r LIST
OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value R -Value
O.
FILM. EX
- -------------------------------
Exterior air film: winter value
--------- ---------
0.17
0.17
1.
STUCCO.0.88
0.875 in stucco
0.,17
0.17
2.
BLDG.PAPER
Buildin paper (felt)
0.06
0.06
3c.
BAT;T.R13
R-13 ba t insul (cavity = 3.5 in)
13.0.0
--
3f.
FIR. 2X4
2x4 fir
--
3.4.6:
4.
GYP. 0.50
0.50 in gypsum or plaster, .board
0.45
0.45'
I.
FILM.IN.WLL
Inside air film: heat sideways
0..68
0.68
--------- ---------
Total Unadjusted R -Values 14.53
5.00
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing
Total
U-Val.ue.: (1 /' 14.53 x 0.85) + (1 / 5.00 x.0.15) =
0.088 Btu/hr-sf-F
Total R -Value: 1 / 0.088 = 11.3'0 h-r-sf-F/Btu
CONSTRUCTION ASSEMBLY Page 2 3R
--------------------------------------------------------------------------�--
Project,Title........... WALLING.LOTI4.,ESTANCIAS Date -06/26/00 09:8
5.23
----------------------------- ----- ---------------------------------____=__
----------------------------------
MTCROPAS5 v5.10 File-1952OA3 Wth-CTZ15S92 Program -FORM 3R
I User#-MP0201 User=Madlin's Enterprises Run -PERMIT CALCULATION I
--------------------------------- Parallel Path Method.
Reference Name . R.38.2X4.24
Description Roof R-38 2x4 24oc
Type Roof
R -Value 38 Hr-sf-F/Btu
Framing
Material .....
=cc ...
Description ..
Spacing ...
Framing Frac...
----------------------------
Sketch of Construction Assembly
FIR. 2X4
Wood
2x4 fir
24 inches on center
0.07
LIST
OF CONSTRUCTION COMPONENTS
`
Mate=rial
Cavity
Frame
Name
Description
R -Value.
R -Value.
O.
FI_LM.EX
---------------------
Exterior air film: winter value
---------
0.17
---------
0.17
1.
SHNGL.ASPHLT
Asphalt shingle roofing
0.44
0.44
2.
BLDG.PAPER,
Building paper (felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0. 62
4.
AIR.RF.3.50
3.5 in & greater air space; heat flow up
0.80
0..80
5.
BATT.R27.0
R-27 batt insulation
27.00
27.00
6c.
BATT.RII.0
R-11 batt insul (cavity > 3.5 in)
1.1.00
--
6f.
FIR..2X4
2x4 fir
--
3.46
7.
GYP.0.50
0.50 in gypsum or plaster board
0:.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.61
-
0.61
Total Unadjusted R -Values
41.1.5
33.62
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing Total
U=Value: (1 / 41.1.5 x 0..93) + (1 / 33.62 x 0.07) = 0.025
Btu/hr-sf-F
Total
R -Value:
1 / 0.025 = 40..51
hr-sf-F/Btu
Madlin's
enterprises
Catherine M. Madlir; Certified Energy Analyst • 760-322-5004 . / 323-3644 (fax) V . V v v ® .
H. V.A. C. Load Calculation
HVAC SIZING Page 1 HVAC
Project Title........... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58.2.3
Project Address.. LOT 14 ESTANCIAS ******* ----- --------
LA QUINTA *v5.'10*
Documentation Author..,. CATHERINE M. MADLIN *******ui ing ermi
Madlin's Enterprises
P.O. Box 1.441 Pian. check DatU
Palm Springs, CA 92262
76:.0-322-5004 Fleid check7-D-Me-
Climate Zone. ..... 1.5 ---------------------
Compliance Method....... MI'CROPAS5 x5.10 for 1998 Standards by Enercomp, Inc.
-----------------------------= -------- --------------------- -----------------
---------------------------------------
MICROPAS5 v5.10 File -19520A3 Wth-CTZ15S9'2 Program -HVAC SIZING
I User#-MP0207 User-Madl.in's Enterprises Run -PERMIT CALCULATION
GENERAL INFORMATION
Floor Area .. ..............'5080 sf
Volume. ............ 6.2266 cf.
Front Orientation........... Front Facing 90 deg (E)
Sizing Location............ PALM SPRINGS
Latitude.......... ..... 33.8 degrees
Winter Outside. Design.. ... 31 F
Winter Inside Design....... 70 F
Summer Outside Design...... 113 F
Summer inside Design....... 78 F
Summer Rangge............ 35' F
Interior Shading Used.,....... No
Exterior Shading Used, ... No
Overhang Shading Used....... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
Note:. The loads shown are only one of the criteria _affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirement's, outside air, outdoor design temperatures, coil sizing,
availability of: equipment, oversizinq safety marginetc., must also be
considered. It is the HVAC designer s responsibilHy to consider all
Heating
Cooling
Description
- - - ---- ------------
(Btuh)
(Btuh)
-----------
Opaque Conduction and Solar......
32492
-----------
18792
Glazing Conduction..... ........
23326
20934.
Glazing Solar ....................
n/a
5019..1
Infiltration.... ......_ _o ...
341.38
22752
Internal Gain........... .......
n/a
3350
Ducts ............................
8996
1160:2
Sensible Load......... ... ....
98957
127620
Latent Load ...... o_ ............
n/a,
25:524
Minimum Total Load
989.51
-
153144
Note:. The loads shown are only one of the criteria _affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirement's, outside air, outdoor design temperatures, coil sizing,
availability of: equipment, oversizinq safety marginetc., must also be
considered. It is the HVAC designer s responsibilHy to consider all
HVAC S:IZ'ING Page 2 HVAC
Project Title... WALLING. LOTI4.ESTANCIAS - Date:.06/26/00 09:58:23
I MICROPAS5 v5.1.0 File-19520A3 Wth-CT215S92 Program-HVAC SIZING
U8er#-MP02d! User Madlin's Enterprises Run-PERMIT CALM LAT.ICIN I
factors when selecting the HVAC equipment.
HVAC SIZING Page 3 HVAC
Project Title WALLING.LOTI4.ESTANCIAS Date..06 26 00 09:58-:23
__________________ _____________________________________
MICROPAS5 x5.1.0 File-1952OA3 Wth-CTZ15S92 Program -HVAC SIZING
I User#-MP020'7 User-Madlin's Enterprises Run -PERMIT CALCULATION I
HEATING LOAD CALCULATIONS
DESIGN CONDITIONS FOR ZONE
'HOUSE':
WINTER DESIGN TEMPERATURES::
Inside Temperature .................................
Outside Temperature ................................
70.0
31.0
F
F
DESIGN TEMPERATURE DIFFERENCES
Standard............ .. .............
.....
.......
39.0
F
CONDUCTIVE HEAT LOSS:
U -value
Heat
Area
(Btu/hr-
TD
Loss,
Description
- --- --
Orientation
----------
(sf)
sf-F)
(F)
(Btuh)
Wall
East
---
1-01-5-.-
x
------
0� 08851
------
x
39.0
_ 3502
Wall
South
_0
5'74.0
x
0.0,885
x
39.0
= 1981
Wall
West
736.0
x
0.0885
x
39.0
= 2540
Wall
North
755.0
x
0.0885
x
39.0
= 2605
Shaded Wall
n/a
0.0885
540.0
,x
x
39.0
= 1863
Wall
Southwest
57.0
x
.0.0885
x
39.0
= 197
Wall
Northwest
57.0
x
0..0,6,85
x
39.0
= 197
Wall
Northeast
34-.5
x
0.0885
x
319.0
= 119
Door
South
60.0
x
0.3300
x
39.0
= 772'
Door
North
21.4
x:0.3300
x
39.0
_ 275
Shaded. Wall
n/a
40.0
x
0.,3300
x
39.0
= -515
Roof
Horizontal
5011.0
x
0.0247
x
39-0
= 48,87
S'labEdge
n/a
405.0
x
6.760.0
x
39.0
= 12004
S'labEdge
n/a
52.0
X
0.5100
x
3.9.0
= 103.4
CONDUCTIVE
TOTALS FOR
OPAQUE
SURFACES
32492
Double Door
Southwest
48.0
x
0.5400
x
39.0
= 101.1
Double Window
Southwest
9.5
x
0.5060
x
39.0
= 185
Double Window
West,
6A
;x
0.,5000
x
39.0
= 117
Double Door
West
48-0
x
0-..,54.00
x
39.0
= 1011
Double Window
Northwest
9.5
x
6.5000
x
39.0
= 185
Double Door
Northwest
48.0
x
0.5400
x
39.0
= 1011
Double Window
West
25.0
x.0.5.400
x
39.0
= 5,27
Double Window
West.
14.0
x'0.5000
x
39.0
= 273
Double Window
West
:12.8
x
0.5000
x
39.0
= 250
Double. Door
East
51.0
x
0.5400
x
39.0
= 1014
Double Window
West
1.4.0
x
0.5.000
x
39.0
= 273
Double Window
West
12.8
x
0.5600
x
39.0
= 250
Double Door
West
51.0
x
0.5400
x
39.0
= 1.074
Double Window
South
40.5
X
0.50.00
x
3.9.0
= 790
Double Window
West
14..0x
0.5000
x
39.0
= 273
Double Window
West
21.0
x
0.50.00
x
3-9.0
= 410
HVAC SIZING
Page
4
HVAC
------------------------------------------------------------------------------------
Project Title........... WALLING.LOTI4.ESTANCIAS
Date..06
---------�--
266l 00
09.58'•23
-
MICROPAS5 x5.10
----- ----------------------------------------------------
File-1952OA3
Wth-CTZ15S.9,2
Program -HVAC SIZING
I User#-MP6207
User-MAdlin's
Enterprises
Run -PERMIT CALCULATION
I
Double
Door
West
----------------------------------------
54.0
x
0.5400
x
39.0
1137
Double
Window
West
14.0
x
0.5000
x
3`9.0 =
273
Double
Window
West.
21.0
x
0.5.00:0
x
39.0 =
410
Double
Door
West
64.0
x
0.5400
x
39.0 =
13.48
Double
'Window
West
14.0
x
0.5000
,x
39.0 =
273
Double
Window
West
21.0
x
0.500'0
x
39.0 =
410
Double
Door
West
54.0
x
0.540`0
x
39.0 =
1137
Double
Door
West
64.0
'x
0.5400
x
39.0 =
1348
Double
Window
West
16.0
x
0.5706
x
39.0 =
3.56
Double,
Door
South
64.:0
x
0.5400
x
39.0 =
1348
Double
Window
West
49.5
x'0.5000
x
39.0 =
965
Double
Window
North
39.0
x
0..5000
x
39.0 =
761,
Double
Window
North
5.0
x
.0.5700
x
39.0 =
1.11
Double
Window
North
1.5,
x
0.5700
x
39.0 =
167
Double
Door
,East
64.0
x
0.5400
x
39.0 =
1348
Double
Door
East
64.0
x
0.5.400
x
39.0 =
1348
Double
Window
East
1.5
x
0.5700
x
39.0 =
167
Double
Window
East
8.0
x
0.570.0
x
39.0 =
178
Double
Door
East
64.0
x
0.5400
x
.39.0 =
:1348
Double
Skylight
Horizontal 1.0
x
0.9400
x
39.0
37
Double
Skylight
Horizontal 4.6
x
0.9400
x
`39.0 =
147
CONDUCTIVE TOTALS` FOR GLAZING SURFACES 23326
INFILTRATION: (Type: Medium)
62266 cuft x 0..78 ac/hr x 0.018 Btu/cuft-F x 39.0 = 34138
SUBTOTAL
DUCT HEAT LOSS: Duct Location: Attic 0.10 x 89.956
TOTAL HEATING LOAD:
COOLING.LOAD CALCULATIONS
-----------------
DESIGN CONDITIONS FOR ZONE 'HOUSE':
SUMMER:DESIGN CONDITIONS::
Inside Temperature...... 78.0 F
Outside Temperature ...... ............ ..,..........113.0 F
Temperature Range ........ ................... 35.0 F
DESIGN EQUIVALENT TEMPERATURE DIFFERENCES
Standard.., ........................................ 35.0 F
Frame Walls and Doors. ...... .... 1_13. f; F
Ceiling Under- Vented Attic ....... ........... .... 54.0 F
8995'6
8996
98951
HVAC SIZING Page 5 HVAC
Project Title.... WALLING.LOTI4.ESTANCIAS Date..06/26/00 09:58:2.3
I-MI"CROPAS5 v5.10 File -19520A3 Wth-CTZ15S92 Program -HVAC SIZING
User#-MP0207 User-Madlin's Enterprises Run -PERMIT CALCULATION I
Frame Partitions...................... 25.0-F-----------------
CONDUCTIVE
HEAT GAIN:
U -value
Heat
.Area
(Btu/hr-
TDeq
Gain
Description
- -----------
Orientation
-----------
(sf)
sf-F)
(F)
(Btuh)
Wall.
East
------
1.015..0
x
-------
0.0`885
x
-------
33.6
--------
= 3018
Wall
South
574.0
x
0.0885
x
33.6
= 1706
Wall
'West
736.0
x
0.0885
x
33.6
= 2188
Wall
North
155.0
x
0.0885
x
33.6
= 2245
Shaded.Wall
n/a
540.0
x
0.0885
x:
25.0
= 1194
Wall
Southwest
'57.0
x
0.0885
x
33.6 =
169
Wall
Northwest
57.0
x
0.08815
x
33.6 =
169
Wall
Northeast
34.5
x
0.0885
x
33.6 =
103
Door
South
60.0
x
0.3360
x
33.6'
= 66'5
Door
North
21.4
x
0.3300
x
33.6
= 2.37
Shaded
'Wahl
n/a
40.0
x
0.330,0
x
25.0
= 310
Roof
Horizontal
5077.0
x
0.0247
x
54.0 =
6767
CONDUCTIVE
TOTALS
FOR
OPAQUE
SURFACES
18792
Double
'Door
Southwest
48.0
x
0..5400
x
35.0
907
Double
Window
Southwest
9.5
x
0.5000
x
35.0 =
166
Double
Window
West
6.0
x
0.5000
x
3.5.0 =
105
Double
Door
West
48.0,x
6.54.00
x
35.0 =
907
Double
Window
Northwest
9.5
x
0.50:00
'x
35.0 =
166
.Double
Door
Northwest
4.8.0
x
0.54.00
x
35..0 =
907
Double
Window
West
25.0
x
0..5400
x
35.0 =
473
Double
Window
West
14.0
x
0..5000
x
35.0 =
245
Double
Window
West
12.8
x
0,.5000
x
35.0 =
224.
Double
Door
East
5.1.0
x
0.5400
x
35.0 =
964
Double
Window
West
1.4.0
x
0.5000
x
35.0 =
245
Double.
Window
West.
12.8
x
0.5000
x
35.0 =
2,24.
Double
Door
West,
51.0
x
0.5400x
35.0 =
964
Double
Window
South
4.0.5
x
0.5000
x
3.5.0 =
709
Double
Window
West
14.0
x
0.5.00,0
x
35.0 =
245
Double
Window_
West
21.0
x
0.500.0
x
35.0 =
368
Double
Door
West
54.0
x
0.5400
x
35.0 =
1.02.1
Double
Window
West
14.0
x
0.50'00
x
35.0 =
245
Double
Window
West
21.0
x
0.5000
x
35.0 =
368
Double
Door
West
64.0
x
0.5406
x
35.0 =
1210
Double
Window
West
14.0
x
0.500.0
x
35.0 =
245
Double
Window
West
21.0
x
0.5606
x
35.0 =
368
Double
Door
West
54.0
x
0..54.00
x
35.0 =
1021
Double
Door
West
64.0
x
0.5400
x
35.0 =
1210
Double
Window
West
1.6.0
x
0.5700
x
35.0 =
319
Double
Door
South
64.0
x
0.54.00
x
35.0 =
1210
Double
Window
West
4.9..5
x
0.5000
x
35.0 =
866
Double
Window
North
3'9.0
x
0.5'000
'x
35.:0 =
683
HVAC SIZING
Page 6
HVAC
------------------------------------------------=---------------�__;�__
Project Title..,....... WALLING.LOTI4.E:STANCIAS
Date..06
26 00
09:58.23
I MICROPAS5 v5.10
________________________-_=___________
File -19520A3 Wth-CTZ15S`92
Program -HVAC SIZING
User#-MP0207
----------------------------------------------------.----------.----_-----
User-Madlin's Enterprises Run
-PERMIT
CALCULATION I
Double
Window
North
5 .0 x
0.5700 x
35.0
---
100
Double
Window
North
7.5 x
0.5700 x
35.0 =
156
Double
Door
East
64.0 x
0.540.0 x
35.0 =
1210
Double
Door
East
64.0 x
0.5.400 x
35.0 =
1210
Double
Window
East
7.5 x
0.5700 x
3'5.0 =
150
Double
Window
East
8.0 x
0.5700 x
35.0 =
160
Double
Door
East
64.0 x
10.5400 x
35.0 =
1210
Double
Skylight
Horizontal
1.0 x
0.9400 x
35.0 =
33
Double
Skylight
Horizontal
4.0 x
0.9460 x
35,.0 =
132
CONDUCTIVE
TOTAL FOR
GLAZING
SURFACES
20934
SOLAR HEAT
GAIN: Note:
SCapprox = SHGC /
0.87
Shading
Heat
Area
Coeff.
Description
Orientation (s.f,)
SHGF SCapprox
(Gain
Btuh)
Double
Door
Southwest
48.0
x
62 x
0.680 =
2023
Double
Window
Southwest
9..5
x
62 x
0.680 =
400
Double
Window
West
6.0
x
73 x
0.680 =
298
Double.
Door
West
48.0
x
73 x
0.680 =
2382
Double
Window
Northwest
9.5
x
48 x
0.680 =
310
Double
Door
Northwest,
48.0
x
48 x
0.6'80 =
1.566
Double
Window
West
25.0
x
73 x
0.680 =
1241
Double
Window
West
14.0
x
73 x
0..680 =
695
Double
Window
West
12.8
x
73 x
0.680 =
63.5
Double
Door
East
51.0
x
73 x
0.680 =
2531
Double
Window
West
1.4.0
x
73 x:
0.6'80 =
6`95
Double
Window
West
12.8
x
73 x
0.680 =
635
Double
Door
West
51.0
x
73 x
0.680 =
2,531
Double
Window
South
40.5
x
32 x
0.680 =
881
Double
Window
West
14.0
x
73 x.
0.6.80 =
695
Double
Window
West
21.0
x
73 x
0.680 =
1042
Double
Door
West
54.0
x
73 x
0.680 =
2680
Double
Window
West
14.0
x
73 x
0.680 =
695
Double
Window
West
21.0
x
73 x
0.680 =
1042
Double
Door
'West
64.0
x
73 x
0.680 =
3176
Double
Window
West
14.0
x
73 x
0.680 _
69.5
Double
Window
West
21.0
x
73 x
0.680 =
1042
Double
'Door
West
54.0
x
73 x
0.680 =
2680
Double
Door
West
64.0
x
73 x
0.68.0 =
3176'
Double
Window
West
1.6.0
'x
73 x
0.799 =
933
Double
Door
South
64.0
x
32 x
0.680 =
1392
Double
Window
West
49.5
x
73 x
0.680 =
24.56
Double
Window
North
39.0
x
15 x
0.680 =
398
Double
Window
North
5.0
x
15 x
0.799 =
60
Double
Window
North
7.5
x
15 x
0.799 =
90
Double
Door
East
64.0
x
73 x
0.680 =
3176
Double
Door
East
64.0
x
73 x
0.680 =
3176
Double
Window
East
7.5
x
73 x..
0.799 -
437
'HVAC SIZING
Page 7
HVAC
Project Title..........
WALLING'.LO,T14.ESTANCIAS
Date 06/26/00
09:58:23
------------------------
MICROPAS5 v5.10
---------------------------------
File=19520A3 Wth-CTZ15S'92
----------------
Program -HVAC'. SIZING
Userf-MP0207
User-Madlin's Enterprises
Run -PERMIT CALCULATION I
.Double Window
-..--- -----------
East
------------------_----------
8. 0 x 73 x 0.799
.
467
Double Door
East 64.0
x 73 x 0.6'80 =
3176
Double Skylight
Horizontal
1.0 x 152 x 0.906 =
138
Double Skylight
Horizontal
4.0 x 152 x 0.906 =
5.51
EXTERIOR
SOLAR .TOTAL (Seat)
501.9.1
INFILTRATION: (Type::
Medium)
62266
cuft x 0.58 ac/hr x 0.018
Btu/tuft-F x 35-0. =
22752.
INTERNAL GAIN (Ig):
1.00 x (
6'x 225.0 + 2000). =
335'0
Dwelling Units
People Appliance --------
SUBTOTAL
116,019
DUCT HEAT, GAIN: Duct
Location: Attic
D.10 x;116019 =
11,602
TOTAL HOURLY SENSIBLE HEAT GAIN 127620
LATENT LOAD: 0.20 x 12'7 62 0 = 25524
TOTAL COOLING LOAD 153144
Maai,in s
enterprises
Catherine M Ma&uz, Certified Energy Analyst . 760-3.22-5004 1,323-3644 (fax) ... .
Manufacturer's Specifications
PALMS TO PINES GLASS
U VALUES FOR TITLE 24 CALCULATIONS
FLEETWOOD or EQUAL MFG.
Effective 9/22%99
L.aT 1i
Iii
• • � • •
�
�^ 1 �_
WCasement
Wfixed (50)
Fixed (530) TB
L.aT 1i
F�MJ -4r- 14