07-2694 (MFD5) CF-6R InstallationAPR. 29. 2009 8:01AM A PIERCE, PLUMBING NO. 3471 P. 5 WSTALLAI`ION CERTIFICATE 1 of 12) CF-6R Ate Address Pe=r Number Li 74S 0C)0 ©-? - iLt Installation certificates (CF-6R) are required for each and every dwelling unit. When the installation of measures that require field verification and diagnostic testing is complete, the builder or the builder's subcontractor shall complete diagnostic testing and the procedures specified in this section. When the installation is complete, the builder or the builder's subcontractor shall complete the Ch-6R (Installation Certificate), and keep it at the building site for review by the building department. The builder also shall provide a copy of the Installation Certificate to the HERS rater for any measures requiring field verification and diagnostic testing, per Section 10-103(a) WATRR T-TPATTNCr gVgTFMq 1 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list ]energy Factor (EF). For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery (RE), Thermal Efficiency, Standby Loss and Rated Input. For instantaneous gas water heaters, list Thermal Efficiency and Rated Input. 2. R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.53. Kitchen Piping; If indicated on the CFA PR, all hot water piping ? 3/4 inches in diameter that runs from the hot water source to the kitchen fixtures is insulated. Faucets & Shower Heads: All faucets and showerheads installed are certified to the Energy Commission, pursuant to Title 24, Part 6, Section 1 *i 1. Central Water Heating in Buildings with Multiple Dwelling Units (required for prescriptive) QAll hot water piping in main circulating loop is insulated to requirements of § 1500) Central hot water systems serving six or fewer dwelling units which have (1) less than 25' of distribution piping outdoors; (2) zero distribution piping underground; (3) no recirculation pump; and (4) insulation on distribution piping that meets the requirements of Section 1500) ©Central hot water systems serving more than 6 dwelling units - presence of either a time control or a time/temperature control ✓ d I, the undersigned, verify that equipment listed above my signature is: 1) the actual equipment installed; 2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF-1R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and 3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Copies to; DTTrLDINGr DEPARTMENT, HEPS RATER (IF APPLICABLE) BUILLIING OWNER AT OCCUPANCY rk- INSTALLATION CERTIFICATE (Page 2 of 12) CF-6R Site Address Permit Number 47-795 Dune Palms Rd, La Quinta, Ca BLDG - 9100 07-2694 An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(a).. FENESTRATION/GLAZING: Item Manufacturer/Brand Name (GROUP LIKE RODUCTS t Product U-factor (5CF-1Rvalue)? Product SHGC (5CF-IRvalue)'- 9 of Pones Total Quantity of Like Product (o tionat) Area Square Peet Exterior Shading Device or Overhang Commenw1.ocation/ Special Features 1. Pella/Impervia 31 32 2 N/A 2. 3. 4. 5. 6. 7. 8. 9. 1 a. Il. 12. 13. 14. 15. �1 Use values from a fenestration product's NFRC label. For fenestration products without an NFRC label, use the default values from Section 116 of the Energy Efficiency Standards. ') Installed U-factor must be less than or equal to values from CF-I R. Installed SHGC must be less than or equal to values from CF-I R, or a shading device (exterior or overhang) is installed as specified on the CF-I R. Alternatively, installed weighted average U-factors for the total fenestration area are less than or equal to values from CF-I R. If using default table SHGC values from § 116 identify whether tinted or not. ✓ 14 1, the undersigned, verify that the fenestration/glazing listed above my signature: 1) is the actual fenestration product installed; 2) is equivalent to or has a lower U-factor and lower SHGC than that specified in the certificate of compliance (Form CF-1R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and 3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #s Signatu Date Installing Subcontractor (Co. Name) OR (if applicable) General Contractor (Co.. Name) OR Owner 5[t qoq OR Window Distributor jj Pella Windows & Doors- HSC, Inc. Item #s Signature Date Installing Subcontractor (Co. Name) OR (if applicable) General Contractor (Co. Name) OR Owner OR Window Distributor Item #s Signature Date Installing Subcontractor (Co. Name) OR (if applicable) General Contractor (Co.. Name) OR Owner OR Window Distributor Copies to: Building Department, HERS Rater (if applicable) Building Owner at Occupancy Residential Compliance Forms April 200.5 (4 Wo t-F-F- .rztveils, INSTALLATION CERTIFICATE (Page 3 of 12) CF-6R Site Address p Permit Number Dv14E G-1uxs �o. �►Qu�sv-�� �i �� 0-7 - abC'iti An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(a). HVAC SYSTEMS: � U 9 I- o0 Heating Equipment Equip Type CEC Certified Mfr. Name and Model # of Identical Efficiency (AFUE. etc.) Duct Location Duct or Piping Heating Load Heating Capacity (pkg. heat um) Number Systems (>_CF-IRvalue) (attic, etc.) R-value (Btu/hr) (Btu/hr) FAra Cci c. Hor PrTfc RL). l9 �00 Wish 141- 3ie p'cc G �. WPC `r j�►o 1Cao Wpr) L-A Cv i(- 3('vi s m v )0 L48 H SG-S -&' t oo Cooling Equipment Equip Type ( kg. heat um ) �RiZiZ S E� CEC Certified Mfr. Name and Model Number # of Identical Systems Efficiency (SEE or EER) > F-IRvalue) Duct Location (attic, etc.) Duct R-value Cooling Load (BnAr) Cooling Capacity (Btu/hr) Coot_. O'N L.5r =14 ACF143aA 5 1 L4_D �? rrs � � L1. a 3®� , PErtS 1NGONFICRL43GR $ a 1 . o I H . 0 Lw000 1. > symbol reads greater than or equal to what is indicated on the CF-IR value. Include both SEER and EER if compliance credit for high EER air conditioner is claimed. ✓ t i I, the undersigned, verify that equipment listed above is: 1) is the actual equipment installed, 2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF-1R) submitted for compliance with the Energy Efficiency Standards for residential buildings, and 3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner Signature VaalDate: 5-►3-OGi Copies to: BUILDING DEPARTMENT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPANCY Residential Compliance Forms April 20W INSTALLATION CERTIFICATE (PAGE 10 OF 12) CF-6R Site Address Permit Number 47-7 NE PALMS RD. BLD# 9100 � f Insulation Installation Quality Certificate ✓ ® Description of Insulation, (CF-6R, formely IC-1) signed by the installer stating: insulation manufacturer's name, material identification, installed R-values, and for loose -fill insulation: minimum weight per square foot and minimum inches ✓ ® Installation meets all applicable requirements as specified in the High Quality Insulation Installation Procedures (ACM, Appendix RH) ✓ FLOOR ❑ Yes No ❑ N/A All floor joist cavity insulation installed to uniformly fit the cavity side -to -side and end -to -end 0 N No � Insulation in contact with the subfloor or rim joists insulated Ps I ENo Na Insulation properly supported to avoid gaps, voids, and compression ✓ WALLS Yes No 0 Wall stud cavities caulked or foamed to provide an air tight envelope E Yes Po® 4A Wall stud cavity insualtion uniformly fills the cavity side -to -side, top -to -bottom, and front -to -back Yes ❑ No 6 No gaps Res P N/A No voids over 3/4" deep or more than 10% of the batt surface area Hard to accesswall stud cavities such as; corner channels, wall intersections, and behind YN o / tub/shower enclosures insulated to proper R-Value Y El No El Small spaces filled Yes Yo0 N/A Rim -joists insulated 0 I No14A Loose fill wall insulation meets or exceeds manufacturer's minimum weight -per -square -foot requirement ✓ ROOF/CEILING PREPARATION Yes Po0 N/A All draft stops in place to form a continuous ceiling and wall air barrier 0 No El All drops covered with hard covers Yes 0 N/A All draft stops and hard covers caulked or foamed to provide an air tight envelope ❑ n All recessed light fixtures IC and air tight (AT) rated and sealed with a gasket or caulk between the YesNO t7TA housinq and the ceiling S 0 Floor cavities on multiple -story buildings have air tight draft stops to all adjoining attics Yes NoYes 4A Eave vents prepared for blown insulation - maintain net free -ventilation area � El Knee walls insulated or prepared for blown insualtion Yes I PoPs N4A Area under equipment platforms and car -walks insulated or accessible for blow insulation I e Attic rulers installed Residental Compliance Forms April 2005 W ALLATION CERTIFICATE Tess DUNE PALMS RD. BLD# 9100 PAGE 11 OF 12) CF-6R ✓ ROOF CEILING BATTS Yes 0 No � No gaps E Yes El No ❑ N/A No voids over 3/4" deep or more than 10% of the batt surface area es No ❑ N/A Insulation in contact with the air -barrier es jj��jj Po IJ/A n❑ Recessed light fixtures covered es IF, R Net free -ventilation area maintained at eave vents ✓ ROOF/CEILING LOOSE -FILL es No ❑ l/A t� Insulation uniformly covers the entire ceiling (or roof) area from the outside of all exterior walls es No ❑ tJ/A Baffles installed at eaves vents or soffit vents - maintain net free-ventilationa rea of eave vent es To❑ tV/A Attic access insulated es o �❑j N/A Recessed light fixtures covered es � To r nn t71A Insulation at proper depth - insualtion rulers visible and indicating proper depth and R-Value M Yes• El Loose -fill insualtion meets or exceeds manufacturer's minimum weight and thickness requirements for the target R-value. Target R-value . Manufacturer's minimum required weight for the target R-value (pounds -per -square -foot). Manufacturer's minimum required thickness at time of installation . Manufacturer's minimum required settled thickness . Note: To receive compliance credit the HERS rater shall verify that the manufacturer's minimum weight and thickness has been achieved for the target R-value. (CF-6R only) DECLARATION ✓ 0 1 hereby certify that the installation meets all applicable requirements as specified in the Insulation Installation Procedures ' Installing Subcontractor (Co. Name) OR General Contractor o. ame O Owner MASCO CONTRACTOR SERVICES Signature: Date: j Copies to: BUILDING DEPARTMENT, HE RATER (IF APPLICABLE), BUILDING OWNER AT OCCUPANCY Residental Compliance Forms April 2005 INSTALLATION CERTIFICATE I - DUNE PALMS RD. BLD# 9100 Subdivision: La Quinta Dune Description of Insulation (Formerly IC-1) Form) 1 RAISED FLOOR Material N/A Thickness (inches) 2 SLAB FLOOR/PERIMETER Material N/A Thickness (inches) Perimeter Insulation Depth (Inches) 3 EXTERIOR WALL Frame Type WOOD 2 X 6 A. Cavity Insulation Material FIBER GLASS INSULATION Thicness (inches) 5.5 INCHES B. Exterior Foam Sheathing _ Material Thicness (inches) 4 FOUNDATION WALL Aaterial N/A Thickness (inches) 12 OF 12) CF-6R Brand Name Thermal Resistance (R-value) Brand Name Thermal Resistance (R-value) Brand Name CERTAINTEED Thermal Resistance (R-value) Brand Name Thermal Resistance (R-value) Brand Name Thermal Resistance (R-value) 5 CEILING Batt or Blanket Type BATT Brand Name CERTAINTEED Thickness (inches) 12 INCHES Thermal Resistance (R-value) Loose Fill Type Brand Contactor's min installed weight/ft lb Minimum thickness Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) Number 9100 inches R-21 R-38 6 ROOF Material N/A Brand Name Thickness (inches) Thermal Resistance (R-value) DECLARATION ✓ N I hereby certify that the abouve insulation was installed in the building at the above location in conformance with the current Energy Efficiency Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where applicable. Item #s Signature Date Installing Subcontractor (Co. Name) OR (if applicable) 3,5 D� General Contractor (Co. Name) OR Owner OR Window Distributor MASCO CONTRACTOR SERVICES Item #s Signature Date Installing Subcontractor (Co. Name) OR (if applicable) General Contractor (Co. Name) OR Owner OR Window Distributor Ite-- #s Signature Date Installing Subcontractor (Co. Name) OR ((� Acable) General Contractor (Co. Name) OR Owner OR Window Distributor Residental Compliance Forms April 2005