BPOL2024-0062DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address APN: Legal Description Property Zoning: Valuation: BUILDING PERMIT eca Qa�&a CALIFORNIA Pool BPOL2024-0062 49499 EISENHOWER DR SOUTHEAST ADULT PI 658190011 Lot 30 MB 269/1 TR 28545-3 CT, 30 $237,320.00 Owner Applicant: PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 03/06/2024 ISSUED DATE: 06/20/2024 LA QUINTA RESORT & CLUB 49-499 EISENHOWER DRIVE, LA QUINTA, CA 92253 Sarah Blataric 31 Tessera Avenue, Foothill Ranch, CA 92610 Contractor: Jeff Solt 25108 MARGURITE PKWY A79, Mission Viejo, CA 92692 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.Ieginfo.ca.gov/calaw.htm1. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 3/6/25 9:33 am Page 1 of 5 BUILDING PERMIT Permit Type: Pool Permit Number: BPOL2024-0062 Property Address: 49499 EISENHOWER DR SOUTHEAST ADULT POOL application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 3/6/25 9:33 am Page 2 of 5 BUILDING PERMIT Permit Type: Pool Permit Number: BPOL2024-0062 Property Address: 49499 EISENHOWER DR SOUTHEAST ADULT POOL EAST AND WEST PUBLIC POOLS, SPA, WITH GAS (2) AND ELECTRICAL (7) OUTLETS [FERRELL ENGINEERING]. EQUIPMENT, EQUIPMENT ENCLOSURE AND BLOCK WALLS PER SEPARATE BUILDING PERMIT. APPROVED PLANS REQUIRED TO BE ONSITE FC ALL INSPECTIONS. 2022 CALIFORNIA BUILDING CODES. .-)nstructien Deta Engineer of Record Douglas R Ferrell Quantity of Detached 1 BBQ Electrical (EA) 7 Spa(s)/Water Feature(s) Number of Gas 2 Mechanical Equipment 0 Garden Wall Linear 0 Outlet(s) Relocation (QTY) F000tage Combination Retaining 0 Total Wall Length 0 Zoning CT Wall Linear Footage (Linear Footage) General Plan TC City Limits Within La Quinta Limits Subdivision Name TR 28545-3 Lot Number 30 Lot Size 233835 Centerlines 85421, 14816, 82973, 82663, 85400, 15410, 82972, 82668 Legal Description Lot 30 MB 269/1 TR 28545-3 Type Group Sq Ft Value Invoice No. Fee Fee Amount Amount Paid INV-00007391 Swimming Pool / Spa PC $124.49 $124.49 Gas Piping System Outlets $15.26 $15.26 Technology Enhancement Fee $8.00 $8.00 Receptacle, switch, lighting, or other outlets PC $30.51 $30.51 Receptacle, switch, lighting, or other outlets $30.51 $30.51 Gas Piping System Outlets PC $30.51 $30.51 Building Standards Administration $10.00 $10.00 Digital Archiving and Records Management Fee - OTC $12.00 $12.00 Detached Spa / Water Feature $228.84 $228.84 Swimming Pool / Spa $228.84 $228.84 Credit Card Convenience Fee $17.97 $17.97 Total for Invoice lNV-00007391 $736.93 $736.93 INV-00010150 Partial Inspection Fee $91.53 $91.53 Total for Invoice lNV-00010150 $91.53 $91.53 Grand Total for Permit $828.46 $828.46 Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 03/07/2024 7:50 03/07/2024 7:50 ------ ------------------------------------ Submittal Document Verification v.1 Generic Action 03/07/2024 7:50 Plan Check v.1 03/07/2024 0:00 05/08/2024 11:57 Building Review (1 Day) v.1 Receive Submittal 03/07/2024 0:00 03/22/2024 9:25 Printed: 3/6/25 9:33 am Page 3 of 5 BUILDING PERMIT Permit Type: Pool Permit Number: BPOL2024-0062 Property Address: 49499 EISENHOWER DR SOUTHEAST ADULT POOL Building Review (1 Day) v.2 Receive Submittal 04/23/2024 0:00 05/08/2024 11:57 Permit Issuance v.1 06/19/2024 14:34 06/20/2024 16:19 ---------------------------------------------------------------------------------------------------------------------------------------- Verify Contractor info & Conditions have been met v.1 Generic Action 06/19/2024 14:34 ---------------------------------------------------------------------------------------------------------------------------------------- Verify & Invoice Fees v.1 Generic Action 06/19/2024 14:34 ---------------------------------------------------------------------------------------------------------------------------------------- Verify Fee Payment & Issue Permit v.1 Generic Action 06/20/2024 16:19 ---------------------------------------------------------------------------------------------------------------------------------------- Print, Attach, and Email Building Permit v.1 Create Report 06/20/2024 16:19 06/20/2024 16:19 Pool Permit Inspection v.1 07/02/2024 10:31 ---------------------------------------------------------------------------------------------------------------------------------------- Pre-Gunite v.1 Inspection 07/02/2024 10:31 07/02/2024 11:55 ---------------------------------------------------------------------------------------------------------------------------------------- Pre-Gunite v.2 Inspection 07/23/2024 0:00 07/24/2024 11:26 ---------------------------------------------------------------------------------------------------------------------------------------- Pre-Gunite v.3 Inspection 07/26/2024 0:00 07/29/2024 10:16 ---------------------------------------------------------------------------------------------------------------------------------------- Underground Plumbing v.1 Inspection 08/14/2024 0:00 08/19/2024 10:55 ---------------------------------------------------------------------------------------------------------------------------------------- Underground Plumbing v.2 Inspection 09/06/2024 0:00 09/09/2024 14:37 ---------------------------------------------------------------------------------------------------------------------------------------- Underground Plumbing v.3 Inspection 10/29/2024 14:28 10/29/2024 14:31 ---------------------------------------------------------------------------------------------------------------------------------------- Underground Electrical v.1 Inspection 08/14/2024 0:00 08/19/2024 10:57 ---------------------------------------------------------------------------------------------------------------------------------------- Underground Electrical v.2 Inspection 09/06/2024 0:00 09/09/2024 14:36 -------------------------------------------------- Underground Electrical v.3 Inspection 10/29/2024 14:30 10/29/2024 14:31 -------------------------------------------------- Underground Gas v.1 Inspection 10/30/2024 0:00 10/30/2024 10:46 ---------------------------------------------------------------------------------------------------------------------------------------- Underground Gas v.2 Inspection 10/30/2024 0:00 ----------------------------- Deck Bond v.1 Inspection 10/29/2024 0:00 10/30/2024 10:54 -- -- -- -- -- -- --............................................................................................................... Deck Bond v.2 Inspection 11/05/2024 0:00 11/06/2024 13:09 ---------------------- Pre-Plaster v.1 .................... Inspection .....---------- 12/06/2024 0:00 12/09/2024 13:47 ---------------------------------------------------------------------------------------------------------------------------------------- Pre-Plaster v.2 Inspection 12/10/2024 0:00 12/12/2024 16:29 ---------------------------------------------------------------------------------------------------------------------------------------- Footing v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- Bond Beam v.1 Inspection Inspections - Final v.1 01/13/2025 0:00 01/23/2025 17:12 ------------------------------------------- Final Pool v.1 Inspection 01/13/2025 0:00 01/15/2025 8:49 ------------------ - Final Pool v.2 Inspection 01/23/2025 17:12 01/23/2025 17:12 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Printed: 3/6/25 9:33 am Page 4 of 5 BUILDING PERMIT Permit Type: Pool Permit Number: BPOL2024-0062 Property Address: 49499 EISENHOWER DR SOUTHEAST ADULT POOL A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the buildina official. Printed: 3/6/25 9:33 am Page 5 of 5 County of Riverside DEPARTMENT OF ENVIRONMENTAL HEALTH POOL/SPA PLAN APPROVAL NOTICE SR # 61089/61090/61091 Date 4-10-2024 PROJECT NAME La Quinta Resort and Club PROJECT LOCATION 49-499 Eisenhower Dr. La Quinta Ca OWNER / CONTRACTOR Blue Pacific Pools PHONE: 949-564-4111 The plans are now approved subject to the conditions listed below. 1. Provide depth markers at water line tiles in addition to what you have shown on deck (3110B et.sec) 2. Provide an approved dry well for back wash. Contact Riversdide County water and Land use Division 760-863-7570. 3. Contact Hazardous Material for permit for your chemicals. 760-863- 4. Provide approval for the under water speaker installation from the La Quinta Building and Safety. *BALL ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL REPAIRS AND INSTALLATIONS SHALL BE DONE UNDER PERMIT FROM THE APPROPRIATE BUILDING & SAFETY DEPARTMENT (CITY OR COUNTY)" CONSTRUCTION INSPECTIONS: Contact the Plan Checker for pre-gunite and pre -plaster inspections at least five (5) working days in advance. A FINAL INSPECTION MUST be made upon completion of ALL work including fencing, safety equipment, and signs. APPROVAL to operate shall not be granted until the facility has passed the FINAL INSPECTIONS and "APPLICATION TO OPERATE" has been completed and PERMIT fees have been paid. Request for inspection should be made at least five (5) working days in advance. Plans Checked By Tracey Ford Phone 760-863-8287 I acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate them during construction: Signature Je&_1441tz yct Date 04.10.2024 Company Name Blue Pacific Pools Corona Hemet Indio Murrieta Palm Springs Riverside -West 2275 S. Main St #204 800 S. Sanderson #200 47-950 Arabia St "A" 30135 Technology Dr #250 544 S. Pasco Dorotea 4065 County Circle Corona, Ca 92882 Hemet, Ca 92545 Indio, Ca 92201 Murrieta, Ca 92563 Palm Springs, Ca 92264 Riverside, Ca 92503 (951) 273-9140 (951) 766-2824 (760) 863-8287 (951)461-0284 (760)320-1048 (951)358-5172 Fax (951)520-8319 Fax (951) 766-7874 Fax (760) 863-8303 Fax (951) 461-0245 Fax (760)320-1470 Fax (951) 358-5017 Department Web Site - www.rivcoeh.org PENTAIR POWERMAX 0 High Performance Commercial Pool Heaters When performance is critical, the PowerMax heater provides peak efficiency and easy maintenance in both indoor and outdoor applications. Models range from 500-2000 MBTU/h with 85% efficiency for commercial swimming pool and theme park applications. Today's PowerMax heater is the result of over 50 years of design and manufacturing experience and is packed with advanced features specific to the commercial swimming pool and water theme park market. Available in seven sizes from 500 to 2000 MBTU/h, the PowerMax heater runs reliably on natural or LP gas and delivers efficiency levels up to 85%. A 10-tube heat exchanger uses finned tubing for the quickest and most efficient heat transfer, and the water heater meets the ASHRAE 90.1 standard for efficiency for use with storage tanks. With superior overall construction and high -efficiency combustion, the PowerMax heater can cut fuel costs significantly compared to conventional water -heating systems, and the energy savings can be substantial over the life of the equipment. Standard Features • Reliable operation with natural or propane gas. • Fan -assisted and filtered combustion air. • Dual -ignition systems for all models over 750,000 BTU. • Digital touch screen controls standard. • Immune to thermal shock down to 30' F. • Built-in automatic mixing system reduces condensation possibilities. • Compact size allows the PowerMax heater to fit through standard doorways. • 200/208 and 575 volt models available on request. • Meets low NOx requirements for cleaner combustion. • Indoor/Outdoor installation same SKU. • One-year limited warranty. See warranty for details. PENTAIR.COM POWERMAX" High Performance Commercial Pool Heaters Dimensional Data Dimensions shown in inches, cm. 500 33'/2 85 15'/4 40 5'/4 15 291/4 76 321/4 83 71/4 20 8'/4 22 46 117 6 15 8 20 6 15 750 45'/2 116 21'/4 55 5'/4 15 291/4 76 32'/4 83 7'/4 20 8'/4 22 58 147 8 20 10 25 8 20 1,000 57/2 146 281/4 73 53/4 15 291/4 76 32'/4 83 7'/4 20 7 18 70 178 8 20 10 25 8 20 1,250 68 172 34 86 1O'/4 26 30'/4 78 291/2 75 8'/4 22 8'/4 22 80 203 12 30 12 30 10 25 1,500 78'/2 199 39'/4 101 10'/4 26 30'/4 78 29/2 75 8'/4 22 8'/4 22 91 231 12 30 12 30 10 25 1,750 89 226 44'/2 113 10'/4 26 30'/4 78 29'/2 75 8'/4 22 8'/4 22 101 256 12 30 14 36 12 30 2,000 99'/2 253 491/4 126 10'/4 26 30'/4 78 291/2 75 8'/4 22 8'/4 22 112 284 12 30 14 36 12 30 *Air and vent connections may be on top or back of the PowerMax heater and are field convertible Sizing Data Heater Water Mixing System Shipping Weight Input, BTU/h Output,BTU/h Gas Conn. Size Conn. Size Water Conn. Indoor Model I x1000 I x1000 I (incheS2) I (inches,) I Size(inches2) lbs. kg 500 500 425 % 2 2 495 225 750 750 638 1'/4 2 2 575 267 1,000 999 849 P/2 2/2 2 685 311 1,250 1,250 1,063 2 2/2 2 730 331 1,500 1,500 1,275 2 2/2 2 830 377 1,750 1,750 1,488 2 2'/2 2 880 400 2,000 1,999 1,699 2 2/2 2 1,025 465 NOTES: I. Input and output must be Berated 2% per 1,000 feet above sea level when installed above 2,000 feet altitude. 2. Dimensions are nominal. Dimensional and Sizing Data 19.7 9 t IV, (W)� I I V- I T si 5 j !OS 353 •.. . pL^%p so 137 son 13.7 3s 33 U.A 9 —� T 3 1 A 35 720 LEF T SIOE NEW H �514 + 293 _ FRONT VIEW 7/ RIGHT SIDE VIEW i V. W' pimp r INLET XM ET 1 cW VIEW 3 WAV ACTUATOR ovnensiona shown in TFMPFHATURE vxhwtm REARVIEW SWITCH - FLOW SWITCH e PENTAIR.COM Sizing Charts and Clearance Data For Indoor Pools 1. Calculate the surface area of the pool in square feet. 2. Refer to the selection chart. 3. Find the closest square footage in the 10' F (6° C) Temperature Difference table and the heater model that corresponds to it. For normal conditions, we recommend using the 100 F(6° C) Temperature Difference columns; this will provide a temperature increase of approximately 6° F(3° C) per 24-hour period. For Outdoor Pools 1. Determine the difference between the desired pool temperature and the average air temperature during the coldest month in which the pool will be used (see the Temperature Difference table below). 2. Calculate the surface area of the pool. 3. Refer to the selection chart. Listed are the maximum pool surface areas for each heater model with typical temperature differences. Make the appropriate selection from the chart. Temperature Difference Surface Area of Pool 500 4,090 370 2,720 250 2,040 180 1,630 150 1,360 120 1,170 100 1,020 90 910 80 810 70 750 6,130 560 4,090 370 3,060 280 2,450 220 2,040 180 1,750 160 1,530 140 1,360 120 1,220 710 1,000 8,180 750 5,450 500 4,090 370 3,270 300 2,720 250 2,340 210 2,040 180 1,820 160 1,630 150 1,250 10,230 950 6,820 630 5,110 470 4,090 370 3,410 310 2,920 270 2,550 230 2,280 210 2,040 180 1,500 12,270 1,130 8,180 750 6,130 560 4,910 450 4,090 370 3,510 320 3,060 280 2,730 250 2,450 220 1,750 14,320 1,330 9,540 880 7,160 660 5,720 530 4,770 440 4,090 370 31580 330 31190 290 2,860 260 2,000 16,370 1,520 10,910 1,010 8,180 750 6,540 600 5,450 500 4,680 430 4,090 370 3,650 330 3,270 300 Clearances Right Side 1" 2.5cm 24" 61cm Top 1" 2.5cm 12" 30cm Left Side 1" 2.5cm 24" 61cm Back* 1" 2.5cm 12" 30cm Front 1" 2.5cm 36" 91cm Vent Per venting system supplier's instructions *When vent and/or air is connected to the back, 36"(91 cm) is suggested. Part Numbers Descriptions PM050ONACC3BXN Indoor/Outdoor, w/pump, Cat.1-III, with elec. Bypass, CI-Cu HX PM075ONACC3BXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu HX PM1000NACC3BXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu HX PM125ONACC3BXN Indoor/Outdoor, w/pump, Cat.1-III, with elec. Bypass, CI-Cu HX PM150ONACC3BXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu HX PM175ONACC3BXN Indoor/Outdoor, w/pump, Cat.1-III, with elec. Bypass, CI-Cu HX PM2000NACC3BXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu HX PMO500NACC3PXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu-Ni HX PM075ONACC3PXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu-Ni HX PM1000NACC3PXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu-Ni HX PM125ONACC3PXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu-Ni HX PM150ONACC3PXN Indoor/Outdoor, w/pump, Cat.1-III, with elec. Bypass, CI-Cu-Ni HX PM1750NACC3PXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu-Ni HX PM2000NACC3PXN Indoor/Outdoor, w/pump, Cat.1-111, with elec. Bypass, CI-Cu-Ni HX NOTE: Other models, including those that meet CSD-1 requirements, and propane gas models are available. Contact factory for details. PENTAIR.COM POWERMAXO High Performance Commercial Pool Heaters Packed With Advanced Features Every PowerMax heater comes standard with a built-in automatic mixing system to make sure low return water temperatures won't cause problematic condensation in the heat exchanger. The mixing system includes an automatic three-way valve, fast -acting electronic actuator, factory mounted and wired pump, and a simple operating control that monitors all important system functions. That means the PowerMax heater can handle return water temperatures as low as 60 degrees without condensation. And, every PowerMax heater has a standard "Backwash Switch" that allows you to safely backwash the filter and avoid high -limit shutdowns by allowing the pump time delay to complete its cycle before shutting down the heater. NOx emissions are among the lowest in the industry at 10 ppm, and the PowerMax heater maintains its efficiency and low NOx levels at all stages of firing. Easy to Install and Service The PowerMax heater makes service easy and operation reliable, because we do all of the setup for you. Whether you use room air for combustion or take air from outside, vent into a chimney or through a sidewall, or install the heater indoors or outside, the PowerMax heater is ready "out of the box." The automatic bypass and combustion systems are factory preset, and no field adjustments are required. Whether you are installing at sea level or at a 10,000-foot elevation, no orifice or component changes are needed. We've also taken service access to a new level. The PowerMax heater makes installation easier by providing a control system that gives installers several different operation modes, selected with the touch of a button. Modes include settings for primary/secondary piping, DHW storage tank systems, B.A.S. controls and other common applications. PENTAIR 1620 Hawkins Ave I Sanford, NC 27330 800.831.7133 1 pentair.com The PowerMax heater features convenient, modular construction that separates the burner trays, gas train and blower assembly to ensure perfect alignment of orifices and burners. Gas manifolds mount on the burner flange, and the burner flanges seal to the air box. In addition, the entire gas train can be easily removed, and the heat exchanger simply lifts out from the top or front of the unit. The air filter is a breeze to clean ... just wash it with soap and water. The PowerMax touch screen control panel is a step beyond smart, it's intuitive. Powerful control logic is easily managed via icon driven, touch screen technology. The result is a control system with the intelligence to manage installations from the simple to the complex. Advanced ease of use functionality includes a home screen summary of operational status, quick start easy configuration, intelligent redundancy and auto cascade configuration for multiple pool heater installations Installation and Service Convenience Features • Reversible vent and intake air terminals (field convertible). • Gas supply right or left side (field convertible). • Reversible water connections to accommodate left or right side piping. • Separate field -wiring terminal panel. • Front panel diagnostics. • Optional rack mounting. • Quick -access panel for igniter replacement. • Combustion chamber sight glasses on both right and left sides. All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. P1-354 04/2021 ©2021 Pentair. All rights reserved. Pentair.com DIGITAL GAS POOL & SPA 17 HEATER Available as Atmospheric, Low NOx, and ASME rA F GAS POOL & SPA HEATER it "Top 10 Best Pool Heaters" Trusted Design I Digital Controls I Flexible Installation PROUDLY BASED IN THE USA DIGITAL GAS POOL & SPA HEATER AMAZING FEATURES Heat Exchanger Our heat exchangers last longer thanks to our straight tube design. By eliminating bends and helical coils we have reduced unnecessary friction in critical areas. Both residential and ASME models are available in copper or cupronickel. Bronze ASME headers provide the strength needed to meet commercial code requirements. Flexible Installation Whether upgrading an existing system or adding a new pool or spa, the Raypak Digital Gas Pool and Spa Heater offers flexible installation solutions thanks to a brilliant low -profile design. Self -Adjusting Burner The self-adjusting burner compensates for gas pressure fluctuations, ensuring that the heater will always burn clean and safe. MORE AMAZING FEATURES Low NOx Certified Available on our Digital Low NOx ASME (207A-407A) models, the air fuel mixture is maintained by a gas valve/blower system that allows the heater to always burn clean and safe. Bonus: Meets additional safety standards and regulations required for Texasl, California and Utah. Digital Controls Equipped with an intelligent control system that can easily be tied into an existing remote system, our heater also features a microprocessor - controlled thermostat for setting the perfect temperature for your pool or spa. Bronze Header with ProTek Shield (ASME Models Only) Blower (Low NOx ASME Models Only) 1 Flow switch option available for ASME Low NOx heaters, Texas Boiler Code compliant. ProTek Shield ProTek Shield is a cutting -edge module that protects the heat exchanger and extends the life of your Raypak Digital Gas Pool and Spa Heater. • Excellent for use in chlorinated and salt water pools • Engineered to take the brunt of the corrosion that naturally occurs over time • Compact design • Easy to replace • • r 401 E �. ProTek Shield on ASME heater. 11 Dr, Digital Gas Pool & Spa Heater CL Models 206A - 406A Flue F- 10" 4-3/8" (254 rn 8-718" (111 mm) (225 mm) 3-3/8" ASME 6-5/8" ASME (86 mm ASME) (168 mm ASME) Outdoor Stackless Top Water Intlet 2" Slip 0 0 • I _7 1l 18" 32-11/16" nm) (830 mm) Electrical !8-5/8" Connection nm) Water Outlet 2" Slip 40" 016 mm) 120 VAC, 240 VAC, 1Ph, 60Hz 1Ph, 60Hz 4 2 P-R206A-E(N/P)-C 199.5 20 6 615/8 10 113/4 187 14 (58.4) (508) (152) (1565) (254) (298) (85) (6.4) P-R266A-E(N/P)-C 266.0 23 7 62 11.5 11 210 16 (77.9) (584) (178) (1575) (292) (279) (95) (7.3) P-R336A-E(N/P)-C 332.5 26 8 63 13 105/8 230 19 (97.4) (660) (203) (1600) (330) (270) (104) (8.6) P-R406A-E(N/P)-C 399 29 9 649/16 14.5 121/a 249 21 (116.9) (737) (229) (1640) (368) (309) (113) (9.5) P-R206A-E(N/P)-X 180.0 20 6 615/a 10 113/4 187 14 (52.7) (508) (152) (1565) (254) (298) (85) (6.4) P-R266A-E(N/P)-X 240.0 23 7 62 11.5 11 210 16 (70.3) (584) (178) (1575) (292) (279) (95) (7.3) P-R336A-E(N/P)-X 300.0 26 8 63 13 105/8 230 19 (87.9) (660) (203) (1600) (330) (270) (104) (8.6) P-R406A-E(N/P)-X 360.0 29 9 649/is 14.5 121/8 249 21 (105.5) (737) (229) (1640) (368) (309) (113) (9.5) B-R206A-E(N/P)- 199.5 20 6 615/8 10.0 113/4 210 14 (C/X) (58.4) (508) (152) (1565) (254) (298) (95) (6.4) B-R266A-E(N/P)- 266.0 23 7 62 11.5 11 235 16 (C/X) (77.9) (584) (178) (1575) (292) (279) (107) (7.3) B-R336A-E(N/P)- 332.5 26 8 63 13 105/8 250 19 (C/X) (97.4) (660) (203) (1600) (330) (270) (113) (8.6) B-R406A-E(N/P)- 399 29 9 649/16 14.5 121/8 273 21 (C/X) (116.9) (737) (229) (1640) (368) (309) (124) (9.5) Fin Tube Material - Copper (C) or Cupronickel (X) Fuel Type - Natural (N) Propane (P) *Note: For outdoor stack height, use "J" dimension for appropriate size plus 6 inches (152 mm). IP DR; CUNNEC ION Front View �26-1/2" (673 mm) m) ELECTRICAL CONNECTION Digital Gas Pool & Spa Heater Low N OX AS M E Models 207A - 407A FLUE 10„ (254 mm Side View 34' (867 mm) STACKLESS OUTDOOR TOP 120 VAC, 240 VAC, 1Ph, 60Hz 1Ph, 60Hz 6 3 B-R207A-EN-(C/X) 199.5 20 6 555/8 10 113/4 200 12 (58.47) (508) (152) (1413) (254) (298) (91) (5) B-R267A-EN-(C/X) 266 23 7 56 11.5 11 210 15 (77.96) (584) (178) (1422) (292) (279) (95) (7) B-R337A-EN-(C/X) 332.5 26 8 57 13 105/8 255 17 (97.45) (660) (203) (1448) (330) (270) (116) (8) B-R407A-EN-(C/X) 399 29 9 581/2 14.5 121/8 269 20 (116.94) (737) (229) (1486) (368) (308) (122) (9) Fin Tube Material - Copper (C) or Cupronickel (X) Fuel Type - Natural (N) Note: Low NOx models are natural gas only Power Consumption on above models: 120VAC - 6 amps 240VAC - 3 amps *For outdoor stack height, use "T dimension for appropriate size plus 6 inches (152 mm). ray pa k.com/pool C 02151 Eastman Avenue Oxnard, CA 93030 1 805-278-5300 SHLW Litho in U.S.A. ©2024 Ra ypak, Inc. I RP-P-601-1 Rev A 1 Effective 4-8-24 1 Replaces 11-1-20 Raypak Tech Corner Looking for quick answers to your Raypak troubleshooting questions? We've got you covered! Skip the wait times on the phone and check out our self -serve resource center, Tech Corner. Our comprehensive database is designed to help you diagnose and solve issues you may encounter with your Raypak equipment quickly and easily. raypak.com/support/tech-corner/ ❑ •1, ❑ ►� PENTAIR INTELLIFLO VARIABLE SPEED PUMPS °il &i2 Variable speed energy savings. Reliable performance for flow -and power -restricted applications. PENTAIR INTELLIFLO° PUMPS ARE ARE A PREFERRED CHOICE OF POOL PROFESSIONALS WORLDWIDE. Reliability and savings, that's why pool builders, retailers and service professionals count on Pentair. z °a• The keypad is rotatable for easy access and has an optional wall mount kit (356904Z)that's sold separately. 1 A POPULAR CHOICE IN VARIABLE SPEED PUMPS A BEST-SELLING INDUSTRY STANDARD. i I IS ALSO MORE VERSATILE. i2 If your pool is in an area that restricts the rate The IntelliFlo i2 Pump provides all the great of flow on replacement pumps, the IntelliFlo i1 featuresthat have made ourflagship IntelliFlo Pump may be your ideal choice. Its hydraulic pumps a best-selling industry standard. But, design reduces flow rates while providing the the IntelliFlo i2 Pump is hydraulically engineered significant energy savings you'd expect from to provide maximum performance on a 15-amp a Pentair variable speed pump. The IntelliFlo breaker. It has a maximum rating of 11.8 amps, i1 Pump also has a maximum rating of 7 amps, which makes retrofits easier in applications that which helps make retrofits easier in applications are limited by existing wire gauge size. Energy that are limited by existing wire gauge size. efficient, automation ready and technologically Plus, it's just as quiet and reliable as ever. advanced —now that's a smart choice. SAVING ENERGY MEANS SAVING MONEY. IntelliFlo Pump innovations add up to greater efficiency, energy savings and universal appeal. IntelliFlo Variable Speed Pumps started an energy -savings revolution. And, the IntelliFlo i1 and i2 Pumps just got better. With energy savings of up to 90%* versus conventional pumps, an easy -to -read rotatable keypad and advanced programming capabilities, pool pros and pool owners love them even more. Plus, they have a record of proven field reliability. IntelliFlo it (011059) WEF 7_5 THP 3.95 IntelliFlo i2 (011060) WEF 6_9 THP 3.95 'Savings based on a variable speed pump compared to a single -speed pump running 12 hours per day at anaverage of $0.16 per kWh in a 20,000-gallon pool. Actual savings may vary based on local utility rates, pool size, pump run time, pump horsepower, pump rpm, plumbing size and length, pump model, service factor and other hydraulic factors. WHATEVER FEATURES YOU FANCY, THESE INTELLIFLO PUMPS CAN HANDLE THEM, EVEN REMOTELY. Designed to handle your pool's automation needs and still deliver maximum energy efficiency. To meet your pool's needs today —and be ready for upgrades tomorrow — there's no better choice than the IntelliFlo it or i2 Variable Speed Pump. Designed to pair with Pentair Automation Systems, these advanced pumps can be programmed to deliver the right flow required for filtration, water features, spas and other equipment. With IntelliFlo i1 and i2, Energy savings of up to 90%* Moves water more efficiently at lower speeds. r774' 82" The IntelliFlo it and i2 Pumps interface with Pentair Automation Systems to give you the convenience of mobile device control.** you can add equipment and features, or change them, without reducing pump performance and while still providing maximum energy efficiency. "-- **Remote access via a computer, smartphone or mobile digital device requires the separate purchase of a ScreenLogic° Interface. Some limitations may apply. INTELLIFLOO il & i2 VARIABLE SPEED PUMPS ONE OF THE QUIETEST PUMPS ON THE PLANET. Advanced engineering delivers whisper -quiet operation. Quiet means you enjoy a more relaxing, satisfying pool and spa experience. That's why we worked so hard to make the IntelliFlo it and i2 Pumps the quietest pumps on the planet Each model uses a totally enclosed fan -cooled (TEFC) permanent magnet motor that helps improve efficiency while reducing noise. At low speeds, you might not even know it's operating. • select® The IntelliFlo H and i2 Pumps have earned the Eco Select brand distinction as one of the greenest and most efficient choices from Pentair. PENTAIR INTELLIFLO it PERFORMANCE CURVES 90 80 70 3 60 5 50 E 40 ii 30 20 10 0• 0 10 20 30 40 50 60 70 80 90 100 110 120 Water Flow Rate in U.S. GaUons per Minute INTELLIFLO i2 PERFORMANCE CURVES 95 1. 3 60 S 50 E 40 'm 30 20 fW 0 r -I 0 20 40 60 80 100 120 140 160 181 Water Flow Rate in U.S. GaUons per Minute NOTE: The charts above demonstrate performance rates at factory preset speeds of 750 RPM,1,500 RPM, 2,350 RPM and 3,110 RPM. However, flow rates can also be custom programmed between the ranges of 400 RPM and 3450 RPM. 400 Regency Forest Dr I Cary, NC 27518 1 United States 1 800.831.7133 1 pentair.com All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. P1-185 07/2021 ©2021 Pentair. All Rights Reserved. PENTAIR TRITONOC SERIES COMMERCIAL SAND FILTERS For commercial and high -end residential swimming pools and other water applications. Available in flow rates from 98 to 141 gallons per minute. Triton C and C-3 Series filters are designed for high efficiency and easy maintenance in high capacity commercial pool applications. A superior internal design levels the sand bed and produces an even water flow for the most efficient filtration possible. Our multi -diffuser system and slotted layer design give the Triton C filter superior filtration capacity and flow for longer cycles between cleanings, which significantly reduces operating costs. Three-inch bulkheads (C-3 models)cut friction loss in half, and flanged connections don't require special adapters. The Triton C Series filter is engineered with single -piece tanks for superior strength, and made from the toughest materials available to withstand harsh chemicals and weather. Capable of increased flow rates to 20 gpm per square foot of filter media, these filters are ideal for commercial applications and tandem installations when several filters are required. STANDARD FEATURES • 2" and 3" plumbing connections for maximum flow. • 2" drains for easy winterizing. • C and C-3 Series filters available in 30" and 36". • Can be combined for tandem installation. PENTAIR.COM TRITONO C SERIES COMMERCIAL SAND FILTERS TRITON HD FILTER The Triton heavy duty(HD)filter is a thirty -inch fiberglass filterthat offers a maximum operating pressure of 75 PSI. This filter is specifically designed for special high-pressure commercial applications that require up to 98 gpm, and is ideal for all heavy-duty commercial applications. TR100 HD Turnover Capacity Gallons TR100C 4.91 74 26,640 35,520 393/4" 301/2" 600lbs. 450 lbs./150 lbs. TR140C 7.06 106 38,160 50,880 451/4" 361/2" 925lbs. 650 lbs./275 lbs. TR1000-3 4.91 74 26,640 35,520 393/4" 301/2" 600lbs. 450 lbs./150 lbs. TR140C-3 7.06 106 38,160 50,880 451/4" 361/2" 926lbs. 660 lbs./276 lbs. *15 GPM/sq.ft. typical commercial flow rate, Triton C Filters are approved for 5-20 GPM/sq.ft. 20.0 18.0 d 16.0 a� 14.0 0 12.0 0 10.0 y 8.0 o- 6.0 4.0 2.0 0 0 PENTAIR 3"-TR100C 823/4" 1715/6" 48"Min. 18"Min. 2,300lbs. 3"-TR140C 883/a" 1715/a" 54"Min. 18"Min. 3,200lbs. 4"-TR140C 953/4" 1935/ad 54"Min. 18"Min. 2,300lbs. 6"-TR140C 1111/4" 247/32" 54"Min. 18"Min. 3,550lbs. Note: 6" piping needs to be rotated upward as shown at 25° so handle will clear the floor 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Flow Rate in GPM 1620 HAWKINS AVE I SANFORD, NC 27330 1 UNITED STATES 1 800.831.7133 1 pentair.com All Pentair trademarks and logos are owned by Pentair plc, or one of its global affiliates. Triton° is a registered trademark of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. P1-15111/19 ©2019 Pentair Water Pool and Spa, Inc. All rights reserved. r, <� BE cs ys Water Chemistry Controls .................. Filtration Controls Equipment Room Controls so Frovidin the world'o moot advanced water chemist oolutior5 'r �� 9 rJ/ ��TECHNOLOGY OB Reliable, Powerful & Flexible Years of reliability For over 30 years aquatic facilites worldwide have trusted BECSys controllers to provide safe and attractive water quality. Reliability and ease of use are the foundation of every BECSys controller. BECSys7 Total Equipment Room & Filtration Control BECSys5 Advanced Expandable Water Chemistry Control BECSys3 Reliable Water Chemistry Control Ethernet is standard on the BECSys7 and BECSys5, and optional on the •i BECSys3, providing Email and/or SMS Alarm Notifications as well as BECSys Live! access from any smartphone, laptop or computer with Internet access. ........................................ Your window into the Equipment Room In this fast -paced world aquatic facility operators need a complete view of both the water quality and the circulation system. BECSys controllers monitor critical system parameters 24/7, providing a complete and continuous view of the entire equipment room, which makes operators more efficient and effective. ✓ pH, ORP, Temperature ✓ Surge tank/Pit level ✓ Free chlorine ✓ Makeup flow ✓ Total/Combined chlorine ✓ Water consumption ✓ Total Alkalinity ✓ Filter influent pressure ✓ TDS/conductivity ✓ Filter effluent pressure ✓ System flow/volume ✓ Filter differential pressure ✓ Circ volume/turnover ✓ Backwash tank/Pit level ✓ Strainer vacuum ✓ Acid inventory ✓ Pump effluent pressure ✓ Liquid chlorine inventory ✓ Pump TDH ✓ Turbidity Readings are available on -screen, recorded in data logs, can trigger an email or SMS alarm notification, and are viewable anywhere with BECSys Live. Operation, maintenance and management staff will always have the information they need right at their fingertips. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000 Take it to the next level: Control With ever-increasing demands on operators' time it only makes sense to let the BECSys controller do what it does best... control! Move beyond basic water chemistry control and realize numerous benefits: ❖ Save chemicals, energy and time ❖ Critical operations are performed consistently & properly ❖ Staff is more productive ❖ Simpler and easier training of new operators ✓ Dual-Setpoint Booster Mode ✓ Bracketed PPM control ✓ Total Alkalinity (TA) control ✓ Digital test kit interface ✓ Saturation index calculators ✓ Combined Cl control ✓ Filtration/Backwash control ✓ Fireman's cycle protection ✓ Circulation pump control ✓ Advanced VFD control ✓ Intelligent autofill ✓ Polymer feed ✓ UV Control ✓ Ozone control ✓ Heater control ✓ TDS/Bleed control Review Graphs Advanced technology for today's world BECSys Alkalinity Meter Monitor Total Alkalinity (TA) with a BECSys7 or BECSys5 with the BECSys Alkalinity Meter. Control TA using acid and COz. BECSys7/5 will actively control both pH and TA simultaneously. No more routine bicarb dumps! Safe & effective pH control A complete line of COz control options including feeders, regulators, manual and automatic tank switchovers, and heaters. BECSys ChemLock Provides a verifiable electrical interlock to assure chemical feeds can only occur while the circulation pump is running. Available as a stand-alone device or factory -configured with BECSys controllers. Advanced flow cell technology Engineered for optimal performance and maximum sensor life. ...................................................... BECSYs Live! BECSys Live is included with every BECSys controller, providing simple and secure 24/7 real-time access from just about any device: PC, Mac, desktop, laptop, tablet and/or smartphone. Monitor status, change settings and review system performance. Review graphs and run reports that summarize key system activity and metrics, so you can easily spot trends. Visit becsys.live to learn more and create your free account. Real-time Dashboards Run Reports OB SQuality... ever step of the wa Y Y p Y Proudly made in the heartland of America Since our founding in 1991 BECS Technology has designed and manufactured over 50,000 aquatics controllers. Our 43,000 ft2 facility in Saint Louis, Missouri is home to an exceptional design team, and manufacturing is performed onsite at this facility where we can personally assure the quality of our products. Yes, we actually do electronics manufacturing... We're rather amused by the recent emphasis on bringing manufacturing "back" to America. We never left. We've been manufacturing in the USA for over 30 years. And when we say "manufacturing" we mean it! We actually do electronics manufacturing at our state of the art factory in Saint Louis using three full scale surface mount (SMT) assembly lines and two through -hole assembly lines. Our commitment to quality is evident in our investment in automation and our highly skilled and experienced team. Design, development and support too! When we say "Made in the USA" we mean designed here too. Our design team includes electrical engineers, software engineers, mechanical engineers, and technicians. They collaborate with our application specialists on system specifications, schematic and circuit board design, firmware/software development, as well as all mechanical design associated with our products such as enclosure, flow cell, and sensor design. A quality product begins with a quality design - having Engineering, Quality, Manufacturing and Tech Support all under one roof assures quality at every step of the process. Ready for a tour? If you're in Saint Louis let us know! Until then please visit our website for additional information You're bn great hands! BECS Technology has been designing and manufacturing the world's most reliable and innovative water chemistry controllers for over 30 years. We take pride in developing aquatics solutions that stand the test of time and are easy to use with features and capabilities that bring real value to our customers and their facilities. Yet even the best equipment requires competent support to reach its full potential. BECSys distributors have been factory -trained and authorized to provide everything you'll need to take full advantage of all the benefits of your BECSys controller through the warranty period and beyond. With a BECSys, you're in great hands! Document#4336-F C_ BECS ,TECHNOLOGY BECSyslnfo@becs.com ♦ www.becs.com providing the world'o moot advanced water chemistry oolutiono 4/22/24, 2:14 PM Commercial Pool Coolers by Glacier Pool Coolers I Glacier Pool Coolers N. UL starwood Nr� �, y W� rIL7 Glacier Pool Coolers Meeting commercial Demands C,rand III models ore cooling pools In resorts, hotels, country dubs, ountic centers, w.terpmks, wildlife exhibits and community Fuels .... od the world, Reducing the temperatures of large commercial stead pools SAVES FACILITIES MONEY by reducing chemical consumption. Cool pools dissipate chemicals Meeting Commercial oemse, - slower, Commercial models ore equipped with 3 phase energy efficient power for low energy costs, so the electric bill barely budges, but the ointenonce to d. down See eavinds analysis using data from. 200,000 dollar YMCA pool in Houston. Tx by drinking below. Our Benefits st Swim teems will enjoy c,n,l,tent and r,g,l,t,d peal water tempemtures year st Helping marine habitat fodlltles maintain cool water tempemtures for rehal llltotlan round and camfort st Guests at hotels call resorts will II mmldg bock or extend their stays at the is Glacier Pool Coolers' extensive product line con handle the smallest plunge pool/spa properties that offer a mole, pool among their omenitles. A refreshing pool at -as to the largest resorts & recreotlonal fcdllties around the world, and we have ore guests to the pool ores, which will increase food and beverage soles at pool develaped a knowledgeahle ,it In depth technical support experience for every side bars odd restaurants, and give an edge over competing resorts Installation srecould st Members of Ageatk Centers, Health Clubs and Country Clubs that hove across to could, pools will enjoy vlsiting ontl exerdsing at these fadlltles [referrals will increase membership) View Our Commercial Models Technical Specs MODEL POOL SIZE DIMENSIONS PIPE DIAM. NOMINAL PAD SIZE DRYWEIGHT (GAccouSl (Ina Es) (INaes) FLOW (FEET) (Las) NM4HT wha. IN OUT hi GPC220 Electrical Specs: 110/115V 1-PH 50/6011 14 Anips 20 Fuse Size GPC2302100 Electrical Specs: 208-240v / 440-4BOv 3-PH 50/60H 20 Fuse Size All Commertiol Models ore Equippetl wiM Thermostat Controls Coll clone, Terhniml Feat to oryuire commercial sizing Form C https://glacierpoolcoolers.com/commercial-pool-coolers/ 1 /2 4/22/24, 2:14 PM Commercial Pool Coolers by Glacier Pool Coolers I Glacier Pool Coolers not s1rnmer mrs m Fm�mn, Me unit has exceeded our so—totiens, and i am thrilled m pmtner with Giuciet and this revolutionary pred-P —Rowdy Gaines 3 Time Olympic Gold Medolint NBC Sports Commentotar & Vire President of Aquotirs, YMCA of C,mml Bond, View Our Raving Reviews Customer Testimonials I bought two of the mister fountain sprayers for my pool. Hooked them up in my pool and ran them for 3 days 24/7 Only got 4 degrees of my pool from 95 to 91 degrees. Pool water still hot and uncomfortable. Waste of time and money.I went ahead and bought a Glacier Pool Cooler and ran it for 9 hours dropped my pool from 95 to 82 degrees. WOW! Me and my family are very happy. Great investment. DA P.-CHARLEMN, SC E 4 'pisclaimer. Glacier Pools is in no way respons!ble for inrtallation, service or repair. This includes monetary cons, workmanship, negligence for the labor, and pans not included with the PmduM. Glader covers pans for the Product only. 5ervice innallers do not work I, Glacier Pool Coolers and are independent ROC licensed contmttors in the!r own state and handle their own wa iesfortheir work and have their own policies on refunds returns etc. Glac!er "Mum Policy: No Refunds after 31 days on productlsl. Glacier only accepts new and unused productlsl within 30 days in original packaging. Inrtalled and removed produ lsl are not eligible for r,f.rd(s). https://glacierpoolcoolers.com/commercial-pool-coolers/ 212 Schematic Diagram Item Description 1 100-01 Hytrol Main Valve 2 CF1-C1 Float Control Optional Features Item Description A X46A Flow Clean Strainer B CK2 Isolation Valve C CV Flow Control (Closing) F Independent Operating Pressure P X141 Pressure Gauge S CV Speed Control (Opening) V X101 Valve Position Indicator Y X43 "Y" Strainer MODEL— 124=01 (Sizes 1/2"-6" / 15 - 150 mm) Float Valve • Accurate and Repeatable Level Control • On -Off or Non -Modulating Action • Fully Adjustable High and Low Level Settings • Simple Design, Proven Reliable • Easy Installation and Maintenance The Cla-Val Model 124-01 Float Valve is a non -modulating valve that accurately controls the liquid level in tanks. This valve is designed to open fully when the liquid level reaches a pre-set low point and close drip -tight when the level reaches a preset high point. This is a hydraulically operated, diaphragm valve with the pilot control and float mechanism mounted on the cover of the main valve. The float positions the pilot control to close the valve when the float contacts the upper stop. The high and low liquid levels are adjusted by positioning the stop collars on the float rod. The difference between high and low levels can be adjusted to as little as 11, (25 mm), or to as much as 18" (450 mm). Level settings can be as much as eleven and one half feet below the valve. The float mechanism may be located remotely from the main valve. See the technical data sheet on Model CF1-C1 Float Control for additional information. Typical Application The Model 124-01 Float Valve is commonly mounted above the high water level in a tank. Globe pattern valves are supplied standard with the float control mounted on the cover as illustrated, with a horizontal discharge. Angle pattern valves are configured to discharge downward. Notes: 1. We recommend protecting tubing and valve from freezing temperatures. 2. Must be inspected periodically. /Pz Installation OUTLET A stilling well (8" / 300mm minimum diameter) must be provided around the float. When the valve is mounted on top of the tank roof, a 2" (50mm) clearance hole should be provided for side movement of the float rod where the rod goes through the top of the tank. A clear independent source of air or water may be used to operate the valve (option F). The pressure from this independent source must at all times be equal to or greater than pressure at the valve inlet .If minimum flowing line pressure is less than 10 psi, consult factory. If the float control is remotely mounted from the main valve, the control may be installed at any elevation above the valve, provided the flowing line pressure in psi is greater than the vertical distance in feet between the valve and the float control. See the technical data sheet on Model CF1-C1 for additional information. Model 124-01 (Uses 100-01 Hytrol Main Valve) Pressure Ratings (Recommended Maximum Pressure - psi) Pressure Class Valve Body & Cover Flanged Grooved Threaded Grade Material ANSI 150 300 300 End$ Standards' Class Class Class Details ASTM A536 Ductile Iron B16.42 250 400 400 400 ASTM A216-WCB Cast Steel B16.5 285 400 400 400 UNS 87850 Bronze B16.24 225 400 400 400 Note: * ANSI standards are for flange dimensions only. Flanged valves are available faced but not drilled. $ End Details machined to ANSI B2.1 specifications. Valvesforhigherpressureareavailable; consultfactoryfordetails Materials Component Standard Material Combinations Body & Cover Ductile Iron Cast Steel Bronze Available Sizes (inches) Y2" - 6" Y2" - 6" Y2" - 6" Available Sizes (mm) 15-150 15-150 15-150 Disc Retainer & Diaphragm Washer Cast Iron Cast Steel Bronze Trim: Disc Guide, Seat & Cover Bearing Bronze is Standard Stainless Steel is Optional Disc Buna-N® Rubber Diaphragm Nylon Reinforced Buna-N® Rubber Stem, Nut & Spring Stainless Steel For material options not listed, consult factory. Cla-Val manufactures valves in more than 50 different alloys. Model 124-01 Dimensions (inches) ---------------------------------- B (Diameter) 100-01 Threaded & Flanged �K X H i C MAX) Inlet outlet y -o--- ----o- 1--? G E F G G - + F+F GGG Inlet D A I~� AAA DDD~ - .....................................r . B (Diameter) 100-01 Grooved } H CC (MAX) In. ! !outlet Inlet -DDDD- AAAA EE Valve Size (Inches) 1 1/2* 1 3/4* 1 1 * I 1 1 11/4 1 11/2 1 2 1 21/2 1 3 1 4 1 6 I A Threaded 3.50 3.50 5.12 7.25 7.25 7.25 9.38 11.00 12.50 - - AA150ANSI - - - - - 8.50 9.38 11.00 12.00 15.00 20.00 ...... AAA 300 ANSI ......... - ......... .......... - ......... - ........ - ......... ......... - _..._.... 9.00 . 10.00 11.62 13.25 15.62 21.00 AAAA Grooved End - - - - - 8.50 9.00 11.00 12.50 15.00 20.00 B Diameter 3.12 3.12 4.38 5.62 5.62 5.62 6.62 8.00 9.12 11.50 15.75 C Maximum 5.88 5.88 6.25 5.50 5.50 5.50 6.50 7.56 8.19 10.62 13.38 CC Maximum Grooved End - - - - - 4.75 5.75 6.88 7.25 9.31 12.12 D Threaded - - - 3.25 3.25 3.25 4.75 5.50 6.25 - - DD 150 ANSI - - - - - 4.00 4.75 5.50 6.00 7.50 10.00 DDD300ANSI - _ - - _ - _ - 4.25 5.00 5.88 6.38 7.88 10.50 DDDD Grooved End - - - - - - 4.75 - 6.00 7.50 - E 0.88 0.88 1.63 1.12 1.12 1.12 1.50 1.69 2.06 3.19 4.31 EE Grooved End - - - - - 2.00 2.50 2.88 3.12 4.25 6.00 F 150 ANSI - - - 2.50 3.00 3.50 3.75 4.50 5.50 FF300ANSI - - - - - 3.06 3.25 3.75 4.13 5.00 6.25 G Threaded - - - 1.88 1.88 1.88 3.25 4.00 4.50 - - GG 150 ANSI - - - - - 4.00 3.25 4.00 4.00 5.00 6.00 GGG 300 ANSI - - - - - 4.25 3.50 4.31 4.38 5.31 6.50 GGGG Grooved End - - - - - - 3.25 - 4.25 5.00 - H NPT Body Tapping 0.125 0.125 0.25 0.375 0.375 0.375 0.375 0.50 0.50 0.75 0.75 J NPT Cover Center Plug 0.125 0.125 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.75 0.75 K NPT Cover Tapping 0.125 0.125 0.25 0.375 0.375 0.375 0.375 0.50 0.50 0.75 0.75 Stem Travel - - - 0.40 0.40 0.40 0.60 0.70 0.80 1.10 1.70 Approx. Ship Weight (lbs) 3 8 8 15 15 15 35 50 70 140 285 Model 124-01 Metric Dimensions (uses 100-01 Hytroi Main Valve) -------------- B (Diameter) 100-01 Threaded & Flanged K X H C (MAX) Inlet Outlet G- -o--- I----�- E --F GG - + FF GGG Inlet D A DDD� —AA AAA Model 100-01 Full Port Hytrol Main Valve BcDlimeter�J CF1-C1 Stainless Steel Float 1t Float Control Overview G- - The Cla Val Model CF1 C1 Float Control is a H(C� float -actuated, multi -port pilot control which provides non -modulating, two -position, on -off InletOutlet operation. It is used primarily to operate remotely located Cla-Val valves requiring +E three-way or four-way pilot valve operation. GGGG Designed for used in open tanks this control + g P , operates on a minimum level change of Inlet—DDDD— approximately one inch. AA AA - Model 124-01 Dimensions (mm) Valve Size (mm) 15* 20* 25* 25 32 40 50 65 80 100 150 A Threaded 89 89 130 184 184 184 238 279 318 — — AA 150 ANSI - - — - - 216 238 279 305 381 508 AAA300ANSI — — — — — 229 254 295 337 397 533 AAAA Grooved End — — — — — 216 228 279 318 381 508 B Diameter 80 80 111 143 143 143 168 203 232 292 400 C Maximum 149 149 159 140 140 140 165 192 208 270 340 CC Maximum Grooved End — — — — — 120 146 175 184 236 308 D Threaded — — — 83 83 83 121 140 159 — — DD150ANSI — — — — — 102 121 140 152 191 254 DDD300ANSI — — — — — 108 127 149 162 200 267 DDDD Grooved End — -...-.--.. — .__.... — . ..... — ........ ._ — — 121 — 152 191 — E 23 23 42 29 29 29 38 43 52 81 110 EE Grooved End — — — — — 52 64 73 79 108 152 F 150 ANSI — — — — — 64 76 89 95 114 140 FF 300 ANSI - - — - - 78 83 95 105 127 159 G Threaded — — — 48 48 48 83 102 114 — — GG 150 ANSI — — — — — 102 83 102 102 127 152 GGG300ANSI — — — — — 102 89 110 111 135 165 GGGG Grooved End - - — - - — 83 - 108 127 - H NPT Body Tapping 0.125 0.125 0.25 0.375 0.375 0.375 0.375 0.50 0.50 0.75 0.75 J NPT Cover Center Plug 0.125 0.125 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.75 0.75 K NPT Cover Tapping 0.125 0.125 0.25 0.375 0.375 0.375 0.375 0.50 0.50 0.75 0.75 Stem Travel - - — 10 10 10 15 18 20 28 43 Approx. Ship Weight (kgs) 1.4.. 1.4 6 7 7 7 16 23 32 64 129 124-01 100-01 Pattern: Globe (G), Angle (A), End Connections: Threaded (T), Grooved (GR), Flanged (F) Indicate Available Sizes Valve Inches h % 1 1 % 1 % 2 2% 3 4 6 8 10 12 14 16 18 20 24 Selection mm 15 20 25 32 40 50 65 80 100 150 200 250 300 350 400 450 500 600 Pattern G G G, A G, A G, A G, A G, A G, A G, A G, A Main Valve End Detail T T T T T F, T, F, T, F, T, F, F, F, 100-01 Gr* Gr Gr* Gr Gr Gr* See the 124-02/624-02 Technical Data Sheet Suggested Maximum 19 33 55 93 125 210 300 460 800 1800 Flow (gpm) for larger sizes. Maximum Intermittent 24 42 68 120 160 260 370 580 990 2250 Suggested Maximum 1.2 2.1 3.5 6 8 13 19 29 50 113 Flow (Liters/Sec) Maximum Intermittent 1.5 2.6 4.3 7.6 10 16 23 37 62 142 100-01 Series is the full internal port Hytrol. *Globe Grooved Only Pilot System Dimensions 124-01 Float Valve (Globe) Size Y21131411 1" 1 %"-1 F" 2" 2Y2" 3" 4" 6" (15 - 20mm) (25 mm) (32 - 40 mm) (50 mm) (65 mm) (80 mm) (100 mm) (150 mm) X 2.50" 5.50" 6.00" 6.25" 6.75" 7.25" 8.00" 10.25" (65 mm) (140 mm) (150 mm) (160 mm) (170 mm) (180 mm) (200 mm) (260 mm) Y 4.25" 4.75" 6.75" 7.00" 7.75" 8.25" 9.50" 10.50" (108 mm) (120 mm) (170 mm) (178 mm) (197 mm) (210 mm) (240) (265 mm) Z (MAX)* 29.75" 28.50" 28.25" 28.50" 28.75" 29.00" 29.25" 29.25" (756 mm) (724 mm) (718 mm) (724 mm) (730 mm) (737 mm) (743 mm) (743 mm) 124-01 Float Valve (Angle) Size 1i , 2" 2%11 3" 4" 6" (40 mm) (50 mm) (65 mm) (80 mm) (100 mm) (150 mm) X 6.00" 6.25" 6.75" 7.25" 8.25" 10.50" (150 mm) (160 mm) (170 mm) (180 mm) (210 mm) (265 mm) Y 6.75" 7.00" 7.75" 7.06" 9.00" 10.00" (170 mm) (178 mm) (197 mm) (179 mm) (230 mm) (254 mm) Z (MAX)' 28.25" 28.50" 28.75" 29.00" 29.25" 29.25" (718 mm) (724 mm) (730 mm) (737 mm) (743 mm) (743 mm) Pilot System Specifications Pressure Rating 300 psi Max. Temperature Rating Water: to 180°F (82°C) Maximum Materials In contact with operating fluid: Nylon -reinforced Delrin,Stainless Steel, Monel, with Buna-N@ seals Float linkage and float rod: Brass and PVC Base plate: 316 Stainless Steel Float: 304 Stainless Steel Float 5318" (180mm) diameter. Globe Pattern 1 /2" to 6" b z Angle Pattern 1 1/2"to 6" Notes: 1) *Z (Max.) is with standard float rod. 2) We recommend providing adequate space around valve for maintenance work 3) Dimensions cover Threaded, Flanged and Grooved connections. Float Rod Standard: Two 12" (300mm) sections PVC rod, 6" (150 mm) & smaller 12" (300mm) extension increments at additional cost. Larger counterweight required if float rod length exceeds 5' (1524mm). Optional: 24" (600mm) stainless steel rod, with 24" (600mm) extension increments at additional cost. Larger counterweight required if float rod length exceeds 2' (600mm). If maximum temperature exceeds 160°F (71 °C) specify stainless steel float rod. Adjustment Range Level Differential: 1" min. to 18" max.(25 - 450mm) with PVC rod. 1" min to 40" max. (25 - 1016mm) with stainless steel rod. Operating Fluids Clean liquids or gases compatible with specified materials. When Ordering, Please Specify 1. Catalog No. 124-01 2. Valve Size 3. Pattern - Globe or Angle 4. Pressure Class 5. Threaded or Flanged 6. Float Rod Material and Length 7. Float Ball Material 8. Desired Options 9. When Vertically Installed CLA_VIAL 1701 Placentia Ave • Costa Mesa CA 92627 • Phone: 949-722-4800 • Fax: 949-548-5441 • E-mail: info@cla-val.com • www.cla-val.com °Copyright Cla-Val 2021 • Printed in USA • Specifications subject to change without notice. E-124-01 (R-03/2021) FEATURES & BENEFITS CONSTRUCTION FDA approved high -density green polyethylene tank provides the light and durable construction required in a portable unit. MOUNTING J-shaped stainless steel wall bracket makes for a well constructed portable mount for easy removal and re -mount. EYEWASH Pulling down the eyewash arm will begin flushing the 16 gallon portable at .4 gpm (1.5 L) during the required 15 minutes, creating a full patterned flushing of the eyes. DESIGN Tank comes complete with a wide -fill opening and threaded cap for quick inspection, cleaning, and filling. Unit also comes equipped with top and side handles making relocation easy. OPTIONS ■ Waste Container: Model 9009 is a twenty -gallon (75.7 L) wastewater container constructed of tough yellow polymer resin. Unit is used to collect water during weekly testing of emergency equipment. ■ Thermal Protection Jacket: Model 9125 is a white thermal protection jacket for 7500 series gravity eyewashes. ■ HawsCLEAN'" Portable Eyewash Cleansing Stick: Model 9083, HawsCLEAN cleansing stick for gravity fed and pressurized portable eyewash equipment. ■ Water Additive: Model 9082, bacteriostatic preservative for use in portable eyewash stations. One 8 oz. (236 ml) bottle will preserve 5 to 20 gallons (18.9 to 75.7 L) of potable water for up to four months. Four bottles per carton. For more information, visit www.hawsco.com or call (888) 640-4297 SPECIFICATIONS Model 7500 portable gravity operated eyewash shall include a FDA approved high -density green polyethylene 16 gallon (60.6 L) tank, ABS plastic eyewash heads with .4 gpm (1.5 L) flow rate over 15 minutes, yellow pull -down activation arm, integral handles on top and sides, wide - fill threaded cap, label -mounted operation and maintenance instructions, and a stainless steel wall bracket. Additive not included — Order separately. APPLICATIONS Where the eyes of any person may be exposed to injurious or corrosive materials, when suitable facilities for quick flushing of the eyes needs to be provided and a continuous supply of water is not available. Although the 7500 may be installed in a wide variety of locations, it is ideal for the remote and low traffic areas where protective measures are still needed. Emergency eyewash facilities shall be in unobstructed and accessible locations that require no more than 10 seconds for the injured person to reach. Model 7500 is certified by CSA to meet the ANSI/ISEA Z358.1 Standard for Emergency Eyewash and Shower Equipment. JW 1455 Kleppe Lane:: Sparks, NV 89431:: p. 775.359.4712 :: f. 775.359.7424:: e. info@hawsco.com :: www.hawsco.com :: 19 Jan, 2024 DISCLAIMER: Continued product improvements make specifications subject to change without notice. Check www.hawsco.com for the latest product information and updates. THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 44 1 /2" - 64 1 /2" 1130mm - 1638mm TO FINISHED FLOOR a 1-1/8" 29mm 2-1/4" 57mm * 21-1/2" 546mm STAND BY "OFF" POSITION 3X 1/4" MOUNTING HARDWARE ❑3 (NOT SUPPLIED) 3X 0 5/16" 3 8mm 1-3/4" 45mm * 23-1/8" 587mm DRAIN TUBE (SUPPLIED) 33 838mm FLOW NOTES: 1. TO COMPLY WITH ANSI Z358.1-2014 FOR EMERGENCY EYEWASH OR EYE/FACE WASH: EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED SUCH THAT FLUSHING FLUID PATTERN IS NOT LESS THAN 33" (838mm) AND NO GREATER THAN 53" (1346mm) FROM SURFACE ON WHICH USER STANDS; AND 6.0" (153mm) MINIMUM FROM WALL OR NEAREST OBSTRUCTION. 2. UNIT MUST BE LEVEL FROM FRONT TO BACK AND SIDE TO SIDE. 0 ALL THREE MOUNTING HOLES ON MOUNTING -BRACKET MUST BE USED TO PROPERLY SECURE EYEWASH UNIT TO WALL. 4. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS (LOCATIONS), WASTE AND SUPPLY REQUIREMENTS, ETC. 5. *DIMENSIONS MAY VARY ±1/2" [12.7mm] MOUNTING ACTIVE "ON" POSITION 7500 /2" Im ® 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM 22 02020 Haws Corporation - All Riahts Reserved. HAWSUand other trademarks used in these materials are the exclusive nronerty of Haws Corporation VI @ Flow Meters h2flo�Iw www.h2flow.net THE BRAND MORE POOL OWNERS & OPERATORS TRUST Ingenious in concept and flawless in operation, FlowVis° has been revolutionizing the way pool owners and operators measure flow since its inception in 2012. With unrivaled average accuracy, greater installation flexibility, and more NSF 50 certified models than any other brand, it's easy to see why FlowVis° is the pool & spa industry's flow meter of choice. KEY FEATURES & BENEFITS • Functions as a flow meter, check valve and velocity meter (select models) • Installation flexibility; installs horizontally, vertically, or even upside-down • 1.5" - 2.5" models can be installed with zero straight pipe requirements • >_98.1% accuracy across the entire model range • Upgrade to FlowVis Digital to allow for remote monitoring and unlock advanced functionality • More NSF 50 certified models than any other brand of flow meter • The only NSF 50, Level 1 certified flow meter • Pool Turnover Rate functionality (FlowVis Digital) • Interfaces with other equipment (FlowVis Digital) • Ability to set flow rate alarms (FlowVis Digital) • Manufactured in the USA • 3-year warranty FLOWVIS° & FLOWVIS° DIGITAL ALLOW YOU TO: Save energy Maximize energy saving potential by running the pump at its required speed. Skim efficiently Balance the filtration system by knowing the flow. Reduce chemical usage Reducing the flow rate to what is required can also reduce chemical usage. » Maintain a cleaner pool Optimize the filter efficiency by operating at its most effective flow rate. Ensure heater efficiency Achieve maximum heat transfer by operating at the optimal flow rate. Optimize water feature operation Achieve precise and repeatable valve positioning for perfect water feature appearance. lin O O FLOWVIS Flow Meters FLOWVIS° MODELS NSF 50 Certified ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Pipe Size 1.5" 1.5" 2" 2" 2.5" 3" 3" 4" 6" 8" Operating Range (GPM) 10-80 10-90 10-110 10-110 10-110 70-240 70-240 150-460 300-1000 600-1800 Average Accuracy 98.7% 98.7% 99.4% 99.0% 99.2% 98.9% 99.2% 99.6% 98.1% N/A* NSF 50 Level YM L1 L1 L1 L1 � L1 1-6MM L1 L1 *FlowVis® model FV-8 includes FlowVis(g) Digital upgrade as standard. For accuracy of this model, please refer to the FV-8 information in the FlowVis Digital table below. FLOWVIS° DIGITAL MODELS NSF 50 Certified ✓ ✓ ✓ ✓ ✓ ✓ Pipe Size 1.5" 1.5" 2" 2" 2.5" 3" Operating Range (GPM) 10-80 10-90 10-110 10-110 10-110 70-240 Average Accuracy 98.6% 99.0% 98.8% 98.5% 98.3% 98.4% NSF 50 Level Li L1 NOTE: FlowVis is the only NSF 50 certified Level 1 flow meter in the world today Guide for NSF 50 Accuracy Levels ./ ./ ✓ ✓ 3" 4" 6" 8" 70-240 150-460 300-1000 600-1800 98.0% 98.3% 98.9% 98.9% L1 L2 L1 L1 Level 1(L1): Average of absolute values of all single point deviations must be :52%. Single point deviations shall not exceed ±4%. Level 2 (11-2): Average of absolute values of all single point deviations must be <_5%. Single point deviations shall not exceed ±7.5%. Level 3 (11-3): Average of absolute values of all single point deviations must be <_10%. Single point deviations shall not exceed ±12.5%. Level 4 (11-4): Average of absolute values of all single point deviations must be <_12.5%. Single point deviations shall not exceed ±15%. Level 5 (L5): Average of absolute values of all single point deviations must be <_15%. Single point deviations shall not exceed ±20%. AN AWARD -WINNING DESIGN In 2021, FlowVis° was named one of Pool & Spa News Top 50 Products for the third time! This award is given annually to the pool industry's most innovative products. PRODUCTS r, s Scan to learn e.bp-001111 more aboutFlowVisa flow meters iln FLOW VIS Flow Meters I SPECIFICATION SHEET: 45 PUMP SERIES ISTENNER SINGLE HEAD ADJUSTABLE OUTPUT I SINGLE HEAD FIXED OUTPUT 45LIH P2 45MH P1 J 45MH P22 s„ SHIPPING WEIGHT 9 Ibs (4 kg) 45M1 45M2 45M3 45M4 45M5 METERING PUMP MMF"Puko 1A79'45 IPX4 U 1 LISTFO l�� C E FD1 ero NRTL !C Positive displacement pump 3-point roller design assists in anti -siphon prutecuon. Pump head requires no valves, allows for easy maintenance. Self -priming against maximum working pressure, toot valve not required. • Pump does not lose prime or vapor lack. Pumps off -gassing solutions and can run dry. Output volume is not affected by back pressure. W 451APHP2 45MP1 45MPHP10 45MP2 45MPHP2.2 45MP3 45MP4 45MP5 SHIPPING WEIGHT 9 Ibs (3.6 kg) M2�T LAM r(Ancl o Tio CONFORMS TO STD. NSF-50 :MN'1M1� alcr. M. SM.e0 V FSt .MIC kXML RM:. OC HIT llC e :a� N!'t1000[7 Otl Oml TFSIiO A! 07R0O11 q "K O ONO. 400"1" AUSOM 10IIFFAW N F0l rurNs —1 r — Injection check valve included with 45MHP & 45MPHP models. Easy to change pump tube; wurlcauon is not required. Pump tubes and pump heads interchange between models. Models tested by WQA to conform to ANSI/NSF STD 61. Adjustable models tested by EiL to conform to ANSVNSF STD 50. All pump accessories Included allow a fast and easy installation. i Stenner Pump Company Phone 904.641.1666 www.stennef.com d 3174 DeSalvo Road US Toll Free 800.683.2378 sales@stenner.com stENNEIt• Jacksonville, Florida 32246 Fax 904.642.1012 ® stenner Pump CornpaN AN Ia jpIts Reserwl: i«............«....»............«.....«...... ..«................ ............ ..«.«....... ....... .«............... ««........ ..««....»........«...»....«................ .........................................................................................««.., i SPECIFICATION SHEET: 45 PUMP SERIES EMMIEE] 1 OUTPUT RANGE adjustable models only, 5%-100%, E 2.5% increments MAXIMUM WORKING PRESSURE 100psl (1.7 bar) for the following models 45MHP2, 45MHP10, 45MHP22 45MPHP2, 45MPHP10, 45MPHP22 26 psi (6.9 bar) for the following models 45M1. 45102. 45M3, 45M4, 45M5 45MP1,45MP2, 45MP3, 45MP4, 45MP5 MAXIMUM AMBIENT and FLUID TEMPERATURE 1250F (520 C) MAXIMUM SUCTION LIFT 25' vertical lift MOTOR TYPE 1/30 HP, shaded pNe. class 6 FINAL MOTOR RPM 26 DUTY CYCLE Coctmi!n rs MOTOR VOLTAGE (AMP DRAW) = 120V 6OHz 1PH (1.7) 220V 6OHz 1PH (0.9) 230V 5OHz 1PH (0.9) International 250V 5OHz 1PH (0.9) International 45 SERIES PUMP ADJUSTABLE OUTPUT POWER CORD PLUG END 120V 60Hz - NEMA 5/ 15, 230V 50Hz - CEE 7/VII 22UV 6014z - NEMA 6/ 15. 250V 50Hz - CEE 7/V1I 1 1 PERISTALTIC TUBE Santoprenee •FDA approved optionalTygothane'** FDA approved TUBE FITTINGS, COMPRESSION NUTS Type 1 rigid PVC -NSF listed SUCTION STRAINER & WEIGHT Type 1 rigid PVC body. ceramic weight - NSF listed SUCTION/DISCHARGE TUBING & FERRULES LOPE polyethylene, NSF and FDA approved CHECK VALVE (injection fitting & body) Type 1 rigid PVC -NSF listed CHECK VALVE DUCKBILL Santoprene" FDA Approved Pellathane" (with Tygothanea tube) ALL PUMP HOUSINGS GF Lexan" Polycarbonme PUMP HEAD ROLLERS HOPE Approximate Output 4 50 Hz 45MIP20 45M 1 I 100 pal (62 bed 25 psi 0.7 bar) rK 11 0.T 10 3.0 0.8 � 11A 0.01 to 0.13 45MMPICO 45M2 1DD pal (6.9 liar) 25 psi (1.7 bar) 02 12 0.5 to 10.0 1.9 to 37.9 0.02 to OA2 45MHP226 45M3 100 psi (6.9 bad 25 P6I (1.7 bed OT 83 1.1 t9 22.0 4.2 to 833 0.051110.92 94 45M4 25 psi (I.T bar) 1.7 to 35.0 6A to 132.5 UT to 1:16 45M5 25 pal (1.1 bar) x5 2.5 to 50.0 9.5 tb 1893 0.10 to 2A8 `Pump supplied with irgecdon check valve to 26.100 psi (2.149 bar) applications 45 SERIES PUMP FIXED OUTPUT 45MPHP2 45MP1 45bIPHP10' 4561P2 45MPHP22• 45MP3 45MP4 45MP5 ROLLER BUSHINGS Bronze 011ite ALL FASTENERS Stainless Seel POWER CORD TYPE SJTO W 'Santoprene- is a regsstered trademark of Adoenced Elastomer System. "tygothane' Is a mg0ered bademanc oe Saint-Gobain Ptrfnrmance Plastics. 'Peflathane' is a registered trademark of The Dow Company. "Lexan' is a registered trademark of General Electric. Consult Geneml Electric for chemical resls!once of Lexan' ACCESSORY KIT SHIPPED WITH EACH PUMP 3 connecting nuts 1/4' or 318" 3 lerruI &s 1/4" or 6mm Europe OR 2 ferrules 3/8' 1 Injection check valve 26-100 psi (1.7.6.9 bar) OR I injection fraing 0-25 psi (0-1.7 ber) t weighted suction line Strainer 114", 318" or 6mm Europe 1 20' roll suction/discharge tubing 1/4" or 3/8', white or IN black OR 6 mm white Europe 1 spate pump tulle 1 mounting oracket 1 Manuel Approximate Output d, 50 Hz 0.0319 OA8 0.02 to 0.27 0.56 to 1.92 11 0.6 to 9.1 i 0A3 l0 0.38 0.31 to 6.32 OA810 LN 0.04 w es 132 w 2&m Is to 30.3 I 0A6 to 1.26 1 1.04 to 21M 0.18 0 30 0.10 to 1.96 2.9210 51.85 33101 .6 0.14 fo 2.78 2.29 to 4625 0.27 to 5.52 0.15 to 3.11 4.44 to 92.01 51111116A 0.21 tb 4.42 3.54 td 73.61 M40 to 7.99 0.2210 4A4 6.60 to 131,46 7.6 to 151.4 f.32 tb 6.31, 5.2810 1D5.14 Approximate outnttt ,* tin Hz Annmmmete nutnut ray r� i Fir 100 nsi (8.9 bad 25 psi (t.7 bar) tt1 #1 3.0 1( 1,4 0.13 0.45 0.27 7.92 9.1 0.88 632 100 osi (6A 1111111) 42 l0A in 0.42 1.58 am 26.32 303 126 21.04 25 psi ILL ttll') ✓ 2 100 pr5i (U bad t7 22.0 83.3 0.92 3.47 L96 5TJM fi6.6 2.78 46.25 25 osl (LT bad 93 25 osi (LT bar) 44 35.0 132.5 Lae am 3t11 92A1 10" 4.42 13.61 25 psi (1.7 bar) #5 50.0 189.3 2.C8 T." 4.44 131.43 151.4 031 105.14 ' -um p supplied with injection check valve for 26-100 psi (1.1-b.9 bar) applications NOTICE: the mrmaboln wnhln tfus chart 6 solely intenceo for use as a 9jide. The OVUM data Is an approomnaoon based on pumping waiet under a conbtrled testing envirawnenL Many vanaoles can a9 ft output of Ure pump. bAto er Pure Company recommer" that all metering pumps undergo field calibration by means of analytical te�ft Id eunfirm their outputs. KEY CHARACTERISTICS OF THE FLOWVIS° PRODUCT LINE FV-15 1.5" pipe SCH40 Valve Body ✓ ✓ 50 psi No 3-Years ✓ FV-15-U 1.5" pipe SCH40 Union J ✓ 50 psi No 3-Years ✓ FV-2 2" pipe SCH40 Valve Body ✓ ✓ 50 psi No 3-Years ✓ FV-2-U 2" pipe SCH40 Union J ✓ 50 psi No 3-Years ✓ FV-C-S 2" pipe SCH40 Valve Body 50 psi No 3-Years ✓ MC -Saline 2" pipe SCH40 Valve Body ✓ 50 psi No 3-Years ✓ FV-25 2.5" pipe SCH40 Valve Body ✓ ✓ 50 psi No 3-Years - ✓ FV-3 3" pipe SCH80 Tee ✓ 50 psi No 3 Years ✓ FV-3-40 3" pipe SCH40 Tee ✓ 50 psi No 3-Years - ✓ FV-4 4" pipe SCH80 Tee ✓ 50 psi No 3 Years ✓ Saddle FV-6 6" pipe SCH80 Clamp ✓ 50 psi No 3-Years ✓ FV-8 8" pipe SCH80 Saddle / 50 psi No 3-Years ✓ Clamp MD 1.5 8 N/A N/A 50 'iMd No I 3-Year FlowVis _Jon_ ■ i d *Advanced features and functionality can be gained by combining FlowVis Digital (model FV-D) with a standard analog FlowVis. Note that a standard FlowVis° model is required for each FlowVis° Digital installation. VELOCITY SCALE While flow and velocity are related, very few people appreciate just how fast water travels through a suction fitting and a filtration system. Safety advocates are now placing an even greater emphasis on this, and FlowVis° is the first flow meter to display the velocity reading as a standard feature. The velocity scale - which provides a readout of velocity in feet -per -second for both the suction and discharge side of the pump - is featured on ten different FlowVis° models. RIGHT: The FlowVis velocity scale offers an accurate readout of velocity in ft/s for both the suction and discharge sides of the pump. As seen here, the right-hand side of the scale is split into two halves; `S' on the left for when FlowVis is installed to the suction side of the pump, and `D' on the right for when FlowVis is installed to the discharge side of the pump. Scan the QR Code to learn more about pairing FlowVis Digital with the Eco-Flow VFD FLOWVIS° DIGITAL ALLOWS YOU TO: » Know the turnover rate » Interface with other equipment All but two U.S. States have a mandated turnover rate for commercial pools and spas. FlowVis Digital is the first and only flow meter that displays the current turnover rate. Retrofit to existing FlowVis units FlowVis Digital is available for both new and existing FlowVis installations and is compatible with most models 1.5" - 8" units. Retrofit models can be installed quickly and easily. FlowVis Digital has the ability to interface with other systems such as heaters, chemical feeders and UV units, so they will only operate above a user -defined flow rate. Set flow rate alarms Set minimum and maximum flow rate alarms to ensure your system is operating as desired. NSF » Know the precise flow rate FlowVis Digital is factory calibrated to mirror a Mag flow meter that has a NIST traceable accuracy of 0.02%. Unlike other digital flow meters, FlowVis Digital is programmed with a simple selection of four DIP switches. » Receive remote indication FlowVis Digital eliminates problems with gaining access to the flow reading, such as in tight spaces, or issues with parallax errors. nn O O Y® FLOWVIS Flow Meters Our innovative solutions are developed with a focus on controlling, monitoring and measuring flow. Contact your authorized 1­12flow Controls solutions provider to find out how our products can help you and your customers. Find an authorized partner at www.h2flow.net/locate-a-partner AC DRIVES I ANTI ENTRAPMENT DEVICES I AUTOFILL SYSTEMS I FLOW METERS ©2023 H2flow Controls, Inc. All rights reserved. H2flow reserves the right to make changes to specifications and product features without notice. Please contact H2flow or visit www.h2flow.net for the most up-to-date versions of our product literature. �sF O=o�Ea.FEo h2flo L7 AS C O N T R O L FV&FV-D Rev.1.2