MA 2025-0002 Setback Decrease & Garage Size Modification - 54217 Eisenhower Dr (03.10.2025)ta aQfra
CALIFORNIA -
March 10, 2025
John Lembeck
HL Miller Inc
2201 E Winston Rd Unit 1
Anaheim, CA 92806
SUBJECT: MINOR ADJUSTMENT 2025-0002
54217 EISENHOWER DR
OTCF.Ta • IiwV'NI609IN
The Design and Development Department has reviewed your Minor Adjustment application (MA
2025-0002), pursuant to Section 9.210.040 of the City of La Quinta Zoning Code.
REQUEST:
Grant up to a 10% adjustment to the front yard setback and the minimum interior dimension of
the garage for a new single-family home located at 54217 Eisenhower Drive. The front yard
setback is being adjusted from 20' to 18' and the garage interior dimension depth is being
reduced from 20' wide to 19' 3", per the attached exhibit.
DECISION:
Approval is granted for the requested adjustment based on the following findings and subject to
the conditions of approval listed below:
1. Minor Adjustment 2025-0002 is consistent with the La Quinta General Plan, in that the
proposal does not alter the approved land use for the property or affect land use on
surrounding similar properties.
2. Minor Adjustment 2025-0002 is consistent with the intent of the La Quinta Zoning Code
in that the requested adjustment will be conditioned to comply with all other development
standards as required under said Zoning Code.
3. Processing and approval of Minor Adjustment 2025-0002 is in compliance with the
California Environmental Quality Act. The adjustment requested falls under CEQA
Guidelines Section 15305(a) as a "Minor Alterations to Land" - Class 5 Categorical
Exemption.
4. Approval of Minor Adjustment 2025-0002 is not detrimental to the public health, safety
and general welfare, nor injurious or incompatible with other properties and land use in
the vicinity. The adjustments have no impact on health or safety issues and will not affect
ta aQfra
CAIJFORNI1 -
physical land use characteristics in the vicinity. The adjustments will be compatible with
the architectural styles of the existing single-family homes.
CONDITIONS OF APPROVAL:
1. A building permit shall be obtained prior to construction. The proposed construction shall
comply with all other development standards as required under the La Quinta Zoning
Code.
Please be advised that the City only approves three Minor Adjustments per lot, regardless of the
percentage of the development standard adjusted. This approval relates only to the minor
adjustments referenced herein and does not imply any entitlement or approval of a building
permit for any structures shown on the plans on file. This approval consists of two Minor
Adjustments, as previously described, and only one Minor Adjustment remains. All other
development standards of the La Quinta Zoning Code are applicable and shall be adhered to in
preparing plans for building plan check.
Thank you for your attention to these items, and if you have any questions, please contact me
directly at (760) 777-7086 and/or at sfernandez(o)_laguintaca.gov .
Sincerely,
Sijifredo ernandez
Associate Planner
Design and Development
PLANNING APPROVAL
ADMINISTRATIVE
CASE # MA2025-0002
EXHIBIT #
INITIAL: sfernandez
DATE : 3/10/2025 5:20:24PM
50''
PL
—B FENCE
TALL0��T4�216A24
A—TT4-216A23
t>
I
i
i
1
I
/
Q
/(N)ADDITION
—
W
—
U
VROVANL'TPNK
N)ADDITION "'—"
""—"'
J
6'-3
— E EXISTING
.'
EIN el o MO
(E)GARAGE
—
—
`(E) GATE---
j
{E) COS
(Q-R[m
_ carvEwnv-oEmo-
16' 5'
I
j
oRrvN ari��-
EIlAY
SY.MNSLOPE
I ..
Reviewed for Code Compliance
April 26, 2023
Inte,mest Consulting Group
{ l (SISK) WALK
. ........._.............. .........._.._.._..__._..�.--
_
N)RED-R-N_—PPROACH
�CATC
SEFAFATEPE.RAIIN EISENHOWER DR
F
50,
L/
M
(E) 6' TALL
BLOCK FENCE
I
0
� JFa
Wll6rzo13
Z
5
a
w
I..
fuC�'��F a44CA 44444444 4A4 44d 4"4"`44444A ' um
�. i'oYr-
Orrr BwALe nerA
z�
O J
U U
NOTE,
DRIVEWAYAPPROACH REQUIRES SEPARATE PERMIT AND INSPECTION
z
p
mU C'.V
FROM CITY OF LAQUIN-PUGLIC WORKS DIVISION
QqN
T EiGR UIMMEDATELYAOJACENTTOTHEFOUNDATIDNSHALLBE
FROM
6SLOU� ,H�U
BUILDING AT A SLOPE OF NOT LESS THAN G' (5 PERCENTSLOPE) IN TI'IE FIRST
W ED
a p r
10 FEET MEASURED PERPENDICULAR TO THE
FACE OF THE WALL. IMPENVIOUS SURFACES WITFIIN 1D FEET OF BUILDING
❑ W
SHALL BE SLOPED A MINIMUM OF 2 PERCENT AWAY
4 1ZiE<y ip
FROM BUILDING. PER CRC R401.3
25 p (9 {.I a E
DATE
4/Y712023
SRES2022-0641
SCALE:
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODECOMPUANCE
SHEET:
.: A 6A,— mndece'r
A-1
DOORSCHEDULE
UMBER
D01
QTV
2
WIDTH
T2'
NLIGNT
80"
DEBCRIPTION
EXT. SLIDER -GLASS PANEL
-PAGTOR
03 ___
SNGC
0.23
002
003
1
1
36'
192"
80"
30"
tIINGEO DOOR PU4
EXT Ot3 PANEL $CIDER-GtAGGPANEL
0
0.3
0
013
004
005
1
i
30'
36
80"
80"
NI GEDSLAU
EXT. HINGED -DOOR E21
➢
0 _..➢
0
0
OU6
DDT
1
1
28
]2"__
80"
30"
HINGEDDOOR PW
DOUBLE HINGED -DOOR PO4
0
0
0
Do
D10
1
i
6
]2"
60'
80"
SLIDER DOOfE PO4
SLIDER -DOOR PO4
0
9
0
0
1
D12
1
60'
28"
➢0'
80"
EX i'.6I
HINGED
R�GTASS�ANEL
-GLASS PANEL
0.3
0 �
01
0
Di6
ii
30"
80"
EXT.. DOUBLER
HINGE0-000R
NGE0.0UOR Pi
PO4
0
0
0
0
o
--- o
IT GHEN.EIEYATJDN.]. .O.KtiC13ENEtEvATkQN2
_13'-11'__-._...._ g•-T.
Q
iW CFM E`(HAUST 4 flow O
w
-I
Y�
^ NNOOM
\1` ° ° ' � H H N ELEVGTInN3 p RY enT
4s O
WALL LEGENG whir 1
IL
EXISTING WALLS ,T�, CLOSET O O
KITCHEN AJ `/
® NEW WALLG "' simrvin�reecis�rv¢iasvruiawnEs xsnmv�nn[�e.[se�<acwsoz.iz
U e 3'9" ` - srwtnar ec°se°. rr°i[
.._ .. _.I_ _ L 1_ _ � BEDROOM 2
° nrciow vEs°wrrsor rynssvv°[xwr rimu L°rosrwuee°ervw �e°ernccaa°Huervnx
CONCRETE renr ECG"
LANDING O caw°ewEmewsr°n wn�amn.r xe°ws ven rnexs°o.a.s.
PANTRY 0 O*Exsss'msnmencxcessswurer_wsnc�oio vxerExraxeiFsrac[,e acre os°ox�W? u Q
O DINING ROOM
PRIMARY BEDROOM W
U I BEDROOM 3 a Z U
ctosET II U U F
Er
J � n z3
1 O W N 0
PRIMARY BATH HALL �" N
O
m ° 1V0 Y gr LAUND
__
BATH BATH ,,,,
® U
CLOSET 1
O _ Q
ZN
n FA o LIVING ROOM 0 O
U�w
csr ixiii sx°u+ I$ � r
sfrn
-r GARAGE Q
® BEDROOM 4 Z U ik U
'S I 6v��ui
o.e�0
...........__....,__..., -- r
r---•---_. T ate°4°Ind
I O ® iOWmOn
II .............. ._....... _.,.._."__._._.__._ gg•_—..__,.,.,.,.,............,........ ..... _............_.
(E)PORCH W ^
I I �
I I
I DATE:
......... _....... -1g�8"__.._.----- -_
PROPOSED FLOOR PLAN /A\ BRES2022-O641 SCALE,
Reviewed for Code Compliance SCALE: 1l4" = 1'-0" CITYOFLAQUINTA
BUILOINGOIVISION
April 26, 2O23 REVIEWEDFOR
laterwest Consulting Group' coDE CDMPLaNGE SHEET:
NUMBER
QTY
WIDTH
HEIGHT
WINDOW SCMEOUIE
DESCRIPTION
U-FACTOR
6HGC
TEMPERED
W01
W02
1
i
32"
32"
48'
72"
DOUBLE CASEMENT-LHVRHR
LEFT
0.3
0.23
0.23
VES
YES
YI03
W04
2
1
BO'
46'
LEFT SLIDING
TRIPLE SLIDING
0.3
0.2
023
WO6
WO6
_,_96"
1
1
_
3s"�� �4➢-
24"
30°
DOUBLE CASE ENT-tfIVRHR
LEFT SLIDING
0.3
0.3
➢13
0.23
WO]
WOe
1
1
60"
24"
60'
30"
LEFT 3LIDING
DOUBLE CA3EMENTdHVRHR
0.3
0.3
➢.23
023
YES
To whom it may concern,
We would like to make Minor Adjustments to-
A-1 Front face of garage set back from face of front
block wall/fence is adjusted to 18' as shown on Site Plan.
A-2 Interior dimensions of garage is adjusted from
20' to 19'-3" as shown on page A-4
Zel Cazares
760 485 2905
HL Miller