Loading...
Carmela TR 31874 (PSN 05596) (Plan 1, 1X, 2, 2X, 3) Solar Master Plans 2019 Code CycleREVISION #2 BCPR2020-0017 CITY OF LA QU I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATEO$/ZO/ZOZZ BY �F ADDED EXTERIOR AC DISCONNECT PLAN 1 2280 THE ESTATES LE, SUITE 92880 . 31874ml )UINTA, 31874m2 GENERAL NOTES: ELECTRICAL 1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4. SEE "PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. !. STRUCTURAL 2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE QRAIL SYSTEM BY QUICK MOUNT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5. GROUND SNOW LOAD = 0 psf 2.6. WIND SPEED = 130 mph 2.7. EXPOSURE CATEGORY = C SCOPE OF WORK 3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH THE ESTATES AT CARMELA 3.1. PLAN:1.2529 3.2. ELEVATIONS: A, B, C 4. BUILDING INFORMATION: 4.1. BUILDING OCCUPANCY GROUP: R3/U 4.2. CONSTRUCTION TYPE: VB INVERTER: SOLAREDGE SE7600H THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: HANWHA Q.PEAK DUO BLK-G6 340 THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 20 MODULES 6.800kW DC / 6.298kW AC ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. .973 cools ls o���� 4;LLk) � Zi TATEN EVANS SOLAR DESIGNER N W O N Q � Lf) H U w Z Z O U 0 U Q O GOVERNING CODES: U) w ALL WORK SHALL CONFORM TO THE FOLLOWING CODES z x 1. 2019 CA BUILDING CODE 0 w 2. 2019 CA ENERGY CODE U) 3. 2019 CA ELECTRICAL CODE > O 4. 2019 CA FIRE CODE W 5. 2019 CA GREEN CODE z w 6. 2019 CA MECHANICAL CODE a 7. 2019 CA PLUMBING CODE a 8. 2019 CA RESIDENTIAL CODE 0 9. ANY OTHER LOCAL AMENDMENTS z Q J Q U ry H Z O U W - � a w o w SHEET INDEX: 0 a PV COVER COVER SHEET w 0- PV RL 2.0 PV LAYOUTS CONT. PV RL 3.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL u PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER HANWHA Q.PEAK DUO BLK-G6 340 MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE �, JTHE* crv« PV SYSTEM PROVIDED BY: wvint.JOiar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1.2529 DATE: 5/7/2021 PV COVER ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC PV ROOF LAYOUTS PLAN 1.2529 FIRECODE OFFSET: ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY JF LAYOUT 3 LAYOUT 7 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 4 LAYOUT 8 RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z 0 U) Lu ry w Q 0 z 0 ry U cn w 0 w ry tc y�0 �` C� • 'co C+ 2 97�;- TATEN EVANS SOLAR DESIGNER civl\� PV SYSTEM PROVIDED BY: v'iv'a t.,bolar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1.2529 DATE: 5/7/2021 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 PV RL 1.0 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC PV ROOF LAYOUTS PLAN 1.2529 FIRECODE OFFSET: ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE BY BY LAYOUT 3 LAYOUT 7 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 4 LAYOUT 8 RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z O U) w ry w Q 0 z 0 ry U cn w 0 w ry ``,Nt1lNllq���� °fC��4 • Nd 4e.o o & Cy 7� `ems 973 r o: ,,*4*0180111111 TATEN EVANS SOLAR DESIGNER CIVlL PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1.2529 DATE: 5/7/2021 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 PV RL 2.0 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC I � r LAYOUT 3 LAYOUT 7 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE BY BY C LAYOUT 4 LAYOUT 8 LAYOUT 9 LAYOUT 10 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE Conduit, Raceways, and J-Boxes (Labeled Every 10') and Installed within 3 ft of Rapid Shutdown Switch, Reflective, and shall be Reflective per 690.31(G)(3) & (4) placed on both Panel Exterior & next to Main Disconnect per POWERWARNING: PHOTOVOLTAIC RAPID SHUTDOWN SWITCH • • PV SYSTEM PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting Means with min. 3/8" black capitalized text on yellow background & 3/16" I WAt-11 r-1 1 .4 W 0 PU kaw" Plaque / Directory at Service Equipment Location and Power Production System Disconnecting oiacK capltaiizea text on white DaCKgrouna per WIU.5b(C)(1)(a) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM, AND REDUCE; SHOCK HAZARD, IN ARRAY All Disconnecting Means - AC & DC Disconnect(s), Load Centers, and Combiner Panels per 690.13(B) & 690.15(D) AWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source Output Connection, Adjacent to BaCk-ted breaker per 105.11(B)(1)(3)(b) QWARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER.CURRENT PROTECTION DEVICE Dual Power Sources in Main Service Panel and Sub Panel(s) per 705.12(B)(3) QWARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM All AC Disconnecting Means - AC Disconnect(s), Combiner Panels, and Load Centers per 690.54 Inverter/Optimizer Specs Optimizer SolarEdge P370 DC Input Power 370 Watts DC Max. Input Voltage 60 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model SolarEdge SE760OH-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max Output Current 32 Amps DC Max Input Current 20 Amps Input Short Circuit Current 45 1 Amps Max Output Fault Current 40 A/20 ms Other Notes PV Module Rating @ STC Module Make/Model Hanwha Q.PEAK DUO BLK-G6+ 340w Max. Power -Point Current (Imp) 10.02 Amps Max. Power -Point Voltage (Vmp) 33.94 Volts Open -Circuit Voltage (Voc) 40.66 Volts Short -Circuit Current (Isc) 10.52 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 340 Watts Max. System Voltage 1000 (IEC)/1000 (UL) Voc Temperature Coefficient -0.27 %/C AHJ Provided Data - Max Temp: 47 'C Min Temp: -7.4 °C Power Source(s) Output Calk: 705.12(B)(2)(3)(b) Main Bus Rating: 200 Amps Main Service Breaker Rating: 200 Amps PV Uprated Output Current: 40 Amps 200A + 40A <= 200 x 1.2; 240 <= 240A, OK • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. • All inverters installed in California are Rule 21 Utility interactive compliant. • Array grounding and bonding designed in compliance with 690.47(A). • Electrical terminations and connectors used in design are listed for use at a minimum of 75°C CITY OF LA Q U I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY J I- MAXIMUM VOLTAGE ***V MAXIMUM CIRCUIT CURRENT ***A 1 MAX RATED OUTPUT CURRENT OF /I RAPID SHUTDOWN SWITCH THE CHARGE CONTROLLER OR DC -TO -DC ***A T FOR SOLAR PV SYSTEM CONVERTER (IF INSTALLED) Conductor Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B) (3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit conductors use the ampacity in the 7S°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC -to -DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 2 Attic): DC -to -DC Converter Output: 12 AWG rated 30 A, 30 A x 0.65 x 1 = 19.5 A >= 15 A (Tag 3 Exterior): Inverter Output: 8 AWG rated 50 A, 50 A >= 40 A Voltage and OCPD Calculations (690.7, 690.9) PV Source Max Circuit Voltage: Module Voc x (1-(AT x Voc Coeff)) [art. 690.7(A)) Q.PEAK DUO BLK-G6+ 340w: 40.66 V x (1-((25 C - -7.4 C) x-0.27%)) = 44.22 V <= 60 V Inverter Output Circuit(s): Listed Output Current x 1.25 [art. 690.9(B)) Inverter 1: SE760OH-US Max Output = 32 A x 1.25 = 40 A <= 40 A (OCPD) System output current w/ continuous duty = 40 A <= 40 A (System OCPD) SITE PLACARD SHOWING ADDITIONAL POWER SOURCE 7 AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL WARNING 10 DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING MAIN BREAKER DE -RATED 2 WARNING: PHOTOVOLTAIC POWER SOURCE 5 SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND (�l DUE TO SOLAR CIRCUITS WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED AMPS MAX ALLOWED IN THE OPEN POSITION DO NOT UPGRADE PHOTOVOLTAIC AC DISCONNECT WARNING 3 PV SYSTEM DISCONNECT (�l MAXIMUM AC OUTPUT CURRENT: *** A [� POWER SOURCE OUTPUT CONNECTION NOMINAL AC OPERATING VOLTAGE: *** V 7 DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE ROOFTOP ARRAY 1 2 �o ., 3 8 o�. EVERY 10' AND �o ?0 WITHIN V OF ELBOWS 9 (,­6" 9� °9 DC Alj DISCONNECT INSIDE �I : S(sI 0 E CAI MOI 10) ( 9 7 11 IF APPLICABLE INSIDE 10 6 PANEL 9 8 M ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVIN I SULAK ME ILK VI51bLt/LULKAbLt A/L SUB PANEL MAIN SERVICE JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT (WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) *** value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account, for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED PER ARTICLES 690 AND 70S AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8" WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. vJ Z 0 U) Nw L.I_ TATEN EVANS SOLAR DESIGNER N Lu o � N ❑ Lo U w Z Z O U U) U < O Of w I- x w w O I- J U U Z W O J w w U < to ❑ w 0- ❑ D w 1 PV SYSTEM PROVIDED BY: ViV1t1t.�:)01ar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1.2529 I DATE: 5/7/2021 PV EE 1.0 REVISION #2 BCPR2020-0017 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATEOHI2O/ZOZZ BY �F ADDED EXTERIOR AC DISCONNECT PLAN 1X DR HORTON 2280 WARDLOW CIRCLE, SUITE 10( CORONA, CA 92880 THE ESTATES AT CARMELA TRACT NO. 31874ml & 31874m2 LA QUINTA, CA 3ENERAL NOTES: ELECTRICAL 1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4. SEE "PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. STRUCTURAL 2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE QRAIL SYSTEM BY QUICK MOUNT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5. GROUND SNOW LOAD = 0 psf 2.6. WIND SPEED = 130 mph 2.7. EXPOSURE CATEGORY = C SCOPE OF WORK 3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH THE ESTATES AT CARMELA 3.1. PLAN:1X.2738 3.2. ELEVATIONS: A, B, C 4. BUILDING INFORMATION: 4.1. BUILDING OCCUPANCY GROUP: R3/U 4.2. CONSTRUCTION TYPE: VB 5. PV 5.1. INVERTER: SOLAREDGE SE7600H 5.2. THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: 5.2.1. HANWHA Q.PEAK DUO BLK-G6 340 5.3. THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1. 22 MODULES 7.480kW DC / 6.928kW AC 5.4. ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. ``��t1t1111111//I��� 01 Calif TATEN EVANS SOLAR DESIGNER N W O N Q � Lf) H U w Z Z O U 0 U Q O GOVERNING CODES: () w ALL WORK SHALL CONFORM TO THE FOLLOWING CODES z x 1. 2019 CA BUILDING CODE 0 w 2. 2019 CA ENERGY CODE U) 3. 2019 CA ELECTRICAL CODE > O 4. 2019 CA FIRE CODE W 5. 2019 CA GREEN CODE z w 6. 2019 CA MECHANICAL CODE a 7. 2019 CA PLUMBING CODE a 8. 2019 CA RESIDENTIAL CODE 0 9. ANY OTHER LOCAL AMENDMENTS z Q J Q U ry H Z O U W - � a w o w SHEET INDEX: C) a PV COVER COVER SHEET w 0- PV RL 2.0 PV LAYOUTS CONT. PV RL 3.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL u PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. SYMBOLS AND ABBREVIATIONS: �M MAIN SERVICE PANEL AND POINT OF INTERCONNECTION a PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE �I PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE �p UTILITY PRODUCTION METER HANWHA Q.PEAK DUO BLK-G6 340 MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE �, JTHE* c1v« PV SYSTEM PROVIDED BY: wvint.JUiar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1 X.2738 DATE: 5/7/2021 PV COVER ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC L ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE BY BY LAYOUT 3 LAYOUT 7 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 4 LAYOUT 8 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 2 ---------- LAYOUT 6 L- ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC CITY OF LA Q U I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY -1 p LAYOUT 3 LAYOUT 7 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 4 LAYOUT 8 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1 X.2738 DATE: 5/7/2021 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 PV RL 2.0 LAYOUT 6 L- ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC CITY OF LA Q U I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY -1 p LAYOUT 3 LAYOUT 7 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 4 LAYOUT 8 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1 X.2738 DATE: 5/7/2021 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 PV RL 2.0 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC PV ROOF LAYOUTS PLAN 1 X.2738 FIRECODE OFFSET: ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY LAYOUT 3 LAYOUT 7 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 4 LAYOUT 8 RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z O U) w ry w Q 0 z 0 ry U cn w 0 w ry TATEN EVANS SOLAR DESIGNER CIV%L PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1 X.2738 DATE: 5/7/2021 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 PV RL 3.0 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE Conduit, Raceways, and J-Boxes (Labeled Every 10') and Installed within 3 ft of Rapid Shutdown Switch, Reflective, and shall be Reflective per 690.31(G)(3) & (4) placed on both Panel Exterior & next to Main Disconnect per POWERWARNING: PHOTOVOLTAIC RAPID SHUTDOWN SWITCH • • PV SYSTEM PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting Means with min. 3/8" black capitalized text on yellow background & 3/16" I WAt-11 r-1 1 .4 W 0 PU kaw" Plaque / Directory at Service Equipment Location and Power Production System Disconnecting oiacK capltauzea text on white backgrouna per WIU.5b(C)(1)(a) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM, AND REDUCE; SHOCK HAZARD, IN ARRAY All Disconnecting Means - AC & DC Disconnect(s), Load Centers, and Combiner Panels per 690.13(B) & 690.15(D) AWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source Output Connection, Adjacent to BaCk-ted breaker per IU5.11(13)(1)(3)(b) QWARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER.CURRENT PROTECTION DEVICE Dual Power Sources in Main Service Panel and Sub Panel(s) per 705.12(B)(3) QWARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM All AC Disconnecting Means - AC Disconnect(s), Combiner Panels, and Load Centers per 690.54 Inverter/Optimizer Specs Optimizer SolarEdge P370 DC Input Power 370 Watts DC Max. Input Voltage 60 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model SolarEdge SE760OH-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max Output Current 32 Amps DC Max Input Current 20 Amps Input Short Circuit Current 45 1 Amps Max Output Fault Current 40 A/20 ms Other Notes PV Module Rating @ STC Module Make/Model Hanwha Q.PEAK DUO BLK-G6+ 340w Max. Power -Point Current (Imp) 10.02 Amps Max. Power -Point Voltage (Vmp) 33.94 Volts Open -Circuit Voltage (Voc) 40.66 Volts Short -Circuit Current (Isc) 10.52 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 340 Watts Max. System Voltage 1000 (IEC)/1000 (UL) Voc Temperature Coefficient -0.27 %/C AHJ Provided Data - Max Temp: 47 'C Min Temp: -7.4 °C Power Source(s) Output Calk: 705.12(1113)(2)(3)(b) Main Bus Rating: 200 Amps Main Service Breaker Rating: 200 Amps PV Uprated Output Current: 40 Amps 200A + 40A <= 200 x 1.2; 240 <= 240A, OK • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. • All inverters installed in California are Rule 21 Utility interactive compliant. • Array grounding and bonding designed in compliance with 690.47(A). • Electrical terminations and connectors used in design are listed for use at a minimum of 75°C CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY J I- MAXIMUM VOLTAGE ***V MAXIMUM CIRCUIT CURRENT ***A 1 MAX RATED OUTPUT CURRENT OF /I RAPID SHUTDOWN SWITCH THE CHARGE CONTROLLER OR DC -TO -DC ***A T FOR SOLAR PV SYSTEM CONVERTER (IF INSTALLED) Conductor Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B) (3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit conductors use the ampacity in the 7S°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC -to -DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 2 Attic): DC -to -DC Converter Output: 12 AWG rated 30 A, 30 A x 0.65 x 1 = 19.5 A >= 15 A (Tag 3 Exterior): Inverter Output: 8 AWG rated 50 A, 50 A >= 40 A Voltage and OCPD Calculations (690.7, 690.9) PV Source Max Circuit Voltage: Module Voc x (1-(AT x Voc Coeff)) [art. 690.7(A)) Q.PEAK DUO BLK-G6+ 340w: 40.66 V x (1-((25 C - -7.4 C) x-0.27%)) = 44.22 V <= 60 V Inverter Output Circuit(s): Listed Output Current x 1.25 [art. 690.9(B)) Inverter 1: SE760OH-US Max Output = 32 A x 1.25 = 40 A <= 40 A (OCPD) System output current w/ continuous duty = 40 A <= 40 A (System OCPD) SITE PLACARD SHOWING ADDITIONAL POWER SOURCE 7 AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL WARNING 10 DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING MAIN BREAKER DE -RATED 2 WARNING: PHOTOVOLTAIC POWER SOURCE S SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND (�l DUE TO SOLAR CIRCUITS WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED AMPS MAX ALLOWED IN THE OPEN POSITION DO NOT UPGRADE PHOTOVOLTAIC AC DISCONNECT WARNING 3 PV SYSTEM DISCONNECT (�l MAXIMUM AC OUTPUT CURRENT: *** A [� POWER SOURCE OUTPUT CONNECTION NOMINAL AC OPERATING VOLTAGE: *** V 7 DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE ROOFTOP ARRAY 1 2 �o ., 3 8 o�. EVERY 10' AND �o ?0 WITHIN V OF ELBOWS 9 (,­6" 9� °9 DC Alj DISCONNECT INSIDE �I : S(sI 0 E CAI MOI 10) ( 9 7 11 IF APPLICABLE INSIDE 10 6 PANEL 9 8 M ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVIN I SULAK ME ILK VI51bLt/LULKAbLt A/L SUB PANEL MAIN SERVICE JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT (WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) *** value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account, for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED PER ARTICLES 690 AND 70S AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8" WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. vJ Z 0 U) Nw L.I_ TATEN EVANS SOLAR DESIGNER N Lu o � N ❑ Lo U w Z Z O U U) U < O Of w I- x w w O I- J U U Z W O J w w U < to ❑ w 0- ❑ D w 1 PV SYSTEM PROVIDED BY: ViV1t1t.�:)01ar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 1 X.2738 I DATE: 5/7/2021 PV EE 1.0 REVISION #2 BCPR2020-0017 CITY OF LA QU I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATEOS/`ZO/ZOZZ BY JF: ADDED EXTERIOR AC DISCONNECT PLAN 2 2280 THE ESTATES LE, SUITE 92880 . 31874ml )UINTA, 31874m2 GENERAL NOTES: ELECTRICAL 1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4. SEE "PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. !. STRUCTURAL 2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE QRAIL SYSTEM BY QUICK MOUNT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5. GROUND SNOW LOAD = 0 psf 2.6. WIND SPEED = 130 mph 2.7. EXPOSURE CATEGORY = C SCOPE OF WORK 3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH THE ESTATES AT CARMELA 3.1. PLAN:2.2679 3.2. ELEVATIONS: A, B, C 4. BUILDING INFORMATION: 4.1. BUILDING OCCUPANCY GROUP: R3/U 4.2. CONSTRUCTION TYPE: VB INVERTER: SOLAREDGE SE7600H THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: HANWHA Q.PEAK DUO BLK-G6 340 THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 20 MODULES 6.800kW DC / 6.298kW AC ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. p • 973� i1" cow) •a....•�'' a cools ls o���� TATEN EVANS SOLAR DESIGNER N W O N Q � Lf) H U w Z Z O U 0 U Q O GOVERNING CODES: U) w ALL WORK SHALL CONFORM TO THE FOLLOWING CODES z x 1. 2019 CA BUILDING CODE 0 w 2. 2019 CA ENERGY CODE U) 3. 2019 CA ELECTRICAL CODE > O 4. 2019 CA FIRE CODE W 5. 2019 CA GREEN CODE z w 6. 2019 CA MECHANICAL CODE a 7. 2019 CA PLUMBING CODE a 8. 2019 CA RESIDENTIAL CODE 0 9. ANY OTHER LOCAL AMENDMENTS z Q J Q U ry H Z O U W - � a w o w SHEET INDEX: 0 a PV COVER COVER SHEET w 0- PV RL 2.0 PV LAYOUTS CONT. PV RL 3.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL u PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER HANWHA Q.PEAK DUO BLK-G6 340 MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE �, JTHE* crv« PV SYSTEM PROVIDED BY: wvint.JOiar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2.2679 DATE: 5/7/2021 PV COVER ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC PV ROOF LAYOUTS PLAN 2.2679 FIRECODE OFFSET: ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY d p LAYOUT 3 LAYOUT 7 ELEVATION: A OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 4 LAYOUT 8 RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z O U) w ry w Q 0 z 0 ry U cn w 0 w ry •,��� red Co�,;��.�. TATEN EVANS SOLAR DESIGNER CIVlL PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2.2679 DATE: 5/7/2021 PV RL 1.0 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC mmp LAYOUT 2 LAYOUT 6 L--- ELEVATION: B OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 3 LAYOUT 7 ELEVATION: B OPTION(S): NONE SCALE: 5/64" = V-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 4 LAYOUT 8 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2.2679 DATE: 5/7/2021 PV RL 2.0 LAYOUT 9 LAYOUT 10 PV ROOF LAYOUTS PLAN 2.2679 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 1 LAYOUT 5 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 2 LAYOUT 6 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY j LAYOUT 3 LAYOUT 7 ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: LEFT 20 MODULES AT 6.800 kW DC ELEVATION: C OPTION(S): NONE SCALE: 5/64" = 1'-0" GARAGE: RIGHT 20 MODULES AT 6.800 kW DC LAYOUT 4 LAYOUT 8 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z O U) w ry w Q 0 z 0 ry U cn w 0 w ry pt Calif N0....... Cb,rf + 2 ° 973��r ��Sed COn�� ,���. TATEN EVANS SOLAR DESIGNER CIVlL PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2.2679 DATE: 5/7/2021 PV RL 3.0 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE Conduit, Raceways, and J-Boxes (Labeled Every 10') and Installed within 3 ft of Rapid Shutdown Switch, Reflective, and shall be Reflective per 690.31(G)(3) & (4) placed on both Panel Exterior & next to Main Disconnect per POWERWARNING: PHOTOVOLTAIC RAPID SHUTDOWN SWITCH • • PV SYSTEM PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting Means with min. 3/8" black capitalized text on yellow background & 3/16" I WAt-11 r-1 1 .4 W 0 PU kaw" Plaque / Directory at Service Equipment Location and Power Production System Disconnecting oiacK capltauzea text on white backgrouna per WIU.5b(C)(1)(a) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM, AND REDUCE; SHOCK HAZARD, IN ARRAY All Disconnecting Means - AC & DC Disconnect(s), Load Centers, and Combiner Panels per 690.13(B) & 690.15(D) AWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source Output Connection, Adjacent to BaCk-ted breaker per IU5.11(13)(1)(3)(b) QWARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER.CURRENT PROTECTION DEVICE Dual Power Sources in Main Service Panel and Sub Panel(s) per 705.12(B)(3) QWARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM All AC Disconnecting Means - AC Disconnect(s), Combiner Panels, and Load Centers per 690.54 Inverter/Optimizer Specs Optimizer SolarEdge P370 DC Input Power 370 Watts DC Max. Input Voltage 60 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model SolarEdge SE760OH-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max Output Current 32 Amps DC Max Input Current 20 Amps Input Short Circuit Current 45 1 Amps Max Output Fault Current 40 A/20 ms Other Notes PV Module Rating @ STC Module Make/Model Hanwha Q.PEAK DUO BLK-G6+ 340w Max. Power -Point Current (Imp) 10.02 Amps Max. Power -Point Voltage (Vmp) 33.94 Volts Open -Circuit Voltage (Voc) 40.66 Volts Short -Circuit Current (Isc) 10.52 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 340 Watts Max. System Voltage 1000 (IEC)/1000 (UL) Voc Temperature Coefficient -0.27 %/C AHJ Provided Data - Max Temp: 47 'C Min Temp: -7.4 °C Power Source(s) Output Calk: 705.12(1113)(2)(3)(b) Main Bus Rating: 200 Amps Main Service Breaker Rating: 200 Amps PV Uprated Output Current: 40 Amps 200A + 40A <= 200 x 1.2; 240 <= 240A, OK • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. • All inverters installed in California are Rule 21 Utility interactive compliant. • Array grounding and bonding designed in compliance with 690.47(A). • Electrical terminations and connectors used in design are listed for use at a minimum of 75°C CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY J i- MAXIMUM VOLTAGE ***V MAXIMUM CIRCUIT CURRENT ***A 1 MAX RATED OUTPUT CURRENT OF /I RAPID SHUTDOWN SWITCH THE CHARGE CONTROLLER OR DC -TO -DC ***A T FOR SOLAR PV SYSTEM CONVERTER (IF INSTALLED) Conductor Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B) (3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit conductors use the ampacity in the 7S°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC -to -DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 2 Attic): DC -to -DC Converter Output: 12 AWG rated 30 A, 30 A x 0.65 x 1 = 19.5 A >= 15 A (Tag 3 Exterior): Inverter Output: 8 AWG rated 50 A, 50 A >= 40 A Voltage and OCPD Calculations (690.7, 690.9) PV Source Max Circuit Voltage: Module Voc x (1-(AT x Voc Coeff)) [art. 690.7(A)) Q.PEAK DUO BLK-G6+ 340w: 40.66 V x (1-((25 C - -7.4 C) x-0.27%)) = 44.22 V <= 60 V Inverter Output Circuit(s): Listed Output Current x 1.25 [art. 690.9(B)) Inverter 1: SE760OH-US Max Output = 32 A x 1.25 = 40 A <= 40 A (OCPD) System output current w/ continuous duty = 40 A <= 40 A (System OCPD) SITE PLACARD SHOWING ADDITIONAL POWER SOURCE 7 AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL WARNING 10 DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING MAIN BREAKER DE -RATED 2 WARNING: PHOTOVOLTAIC POWER SOURCE 5 SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND (�l DUE TO SOLAR CIRCUITS WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED AMPS MAX ALLOWED IN THE OPEN POSITION DO NOT UPGRADE PHOTOVOLTAIC AC DISCONNECT WARNING 3 PV SYSTEM DISCONNECT (�l MAXIMUM AC OUTPUT CURRENT: *** A [� POWER SOURCE OUTPUT CONNECTION NOMINAL AC OPERATING VOLTAGE: *** V 7 DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE ROOFTOP ARRAY 1 2 �o ., 3 8 o�. EVERY 10' AND �o ?0 WITHIN V OF ELBOWS 9 (,­6" 9� °9 DC Alj DISCONNECT INSIDE �I : S(sI 0 E CAI MOI 10) ( 9 7 11 IF APPLICABLE INSIDE 10 6 PANEL 9 8 M ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVIN I SULAK ME ILK VI51bLt/LULKAbLt A/L SUB PANEL MAIN SERVICE JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT (WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) *** value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account, for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED PER ARTICLES 690 AND 70S AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8" WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. TATEN EVANS SOLAR DESIGNER N w o � N ❑ Lo U Lu Z Z o 0 U) U) U LNU O Of w x w w O I- J U U Z w O J w w U < to ❑ w 0- ❑ ::) w 1 ,S\ONAL ,E oPv T 4Q v 0 a * NO. E 22210 ��OF CAL1F� 5/7 021 License Expires: 3/31/2022 PV SYSTEM PROVIDED BY: vivalt.,bolar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2.2679 I DATE: 5/7/2021 PV EE 1.0 REVISION #2 BCPR2020-0017 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATEOH/ZO/ZOZZ BY �F ADDED EXTERIOR AC DISCONNECT PLAN 2X DR HORTON 2280 WARDLOW CIRCLE, SUITE 10( CORONA, CA 92880 THE ESTATES AT CARMELA TRACT NO. 31874ml & 31874m2 LA QUINTA, CA 'DENERAL NOTES: ELECTRICAL 1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4. SEE "PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. STRUCTURAL 2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE QRAIL SYSTEM BY QUICK MOUNT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5. GROUND SNOW LOAD = 0 psf 2.6. WIND SPEED = 130 mph 2.7. EXPOSURE CATEGORY = C SCOPE OF WORK 3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH THE ESTATES AT CARMELA 3.1. PLAN:2X.2911 3.2. ELEVATIONS: A, B, C 4. BUILDING INFORMATION: 4.1. BUILDING OCCUPANCY GROUP: R3/U 4.2. CONSTRUCTION TYPE: VB 5. PV 5.1. INVERTER: SOLAREDGE SE7600H 5.2. THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: 5.2.1. HANWHA Q.PEAK DUO BLK-G6 340 5.3. THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1. 23 MODULES 7.820kW DC / 7.243kW AC 5.4. ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. `1111111//��'' '%I a 01 cal - 0..- 9730 4?" ���.`secco1a`'o''., TATEN EVANS SOLAR DESIGNER N W O 04 o—Lo U w Z Z O U Ln 0 U Q O GOVERNING CODES: () w ALL WORK SHALL CONFORM TO THE FOLLOWING CODES z x 1. 2019 CA BUILDING CODE 0 w 2. 2019 CA ENERGY CODE U) 3. 2019 CA ELECTRICAL CODE > O 4. 2019 CA FIRE CODE W 5. 2019 CA GREEN CODE z w 6. 2019 CA MECHANICAL CODE a 7. 2019 CA PLUMBING CODE a 8. 2019 CA RESIDENTIAL CODE 0 9. ANY OTHER LOCAL AMENDMENTS z Q J Q U ry H Z O U W - � a w o w SHEET INDEX: C) a PV COVER COVER SHEET w 0- PV RL 2.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV SR 1.0 STRUCTURAL w PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. SYMBOLS AND ABBREVIATIONS: �M MAIN SERVICE PANEL AND POINT OF INTERCONNECTION a PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE �I PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE �p UTILITY PRODUCTION METER HANWHA Q.PEAK DUO BLK-G6 340 MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE �, JTHE* c1v« PV SYSTEM PROVIDED BY: vi int.JUiar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2X.2911 DATE: 5/7/2021 PV COVER PV ROOF LAY PLAN 2X.2911 ELEVATION: A / OPTION(S): NO SCALE: V-0" GARAGE: 23 M ULES AT 7.820 kW DC ELEV ION: A OPT ON(S): NONE S ALE: 1/16" = V-0" G RAGE: RIGHT 23 MODULES AT 7.820 kW DC LAYOUT 1 LAYOUT 5 EL AT ION: A PTION(S): NONE �CALE: 1/16" = V-0" GARAGE: LEFT 23 MODULES AT 7.820 kW DC ELEVATION: A OPTION(S): NONE SCALE: 1/16" = V-0" GARAGE: RIGHT 23 MODULES AT 7.820 kW DC ELEVATION: B ELEVATION: B OPTION(S): NONE OPTION(S): NONE SCAL : 1/ if= 1'-0" SCALE: 1/16" = V-0" GARA :LEFT GARAGE: LEFT 23 MODULES AT 7.820 kW DC 23 MODULES AT 7.820 kW DC LAYOUT 2 LAYOUT 6 A NEVA N: A OP N(S): NONE SCALE: 1/16" = V-0' GARAGE: LEFT 23 MODULES AT 7.820 kW DC ELEVATION: A OPTION(S): NONE SCALE: 1/16" = V-0" GARAGE: RIGHT 23 MODULES AT 7.820 kW DC ELEVATION: B OPTION(S): NONE SCALE: 1/16" = V-0" GARAGE: RIGHT N 23 MODULES AT 7.8 kW DC CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE BY BY LAYOUT 3 LAYOUT 7 LAYOUT 3 ELE TION� \ OPTION : NONE \\, SCALE: 1 6" = 1'-0" GARAGE: LEFT 23 MODULES AT 7.820 kW DC ELEVATION: A OPTION(S): NONE SCALE: 1/16" = V-0" GARAGE: RIGHT 23 MODULES AT 7.820 kW DC ELEVATION: B OPTION(S): NONE SCALE: 1/16" = V-0" GARAGE: RIGHT 23 MODULES AT 7.8 0 kW DC LAYOUT 4 LAYOUT 8 LAYOUT 4 101 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z O U) w ry w Q 0 z 0 ry U U) w 0 w `���{11NIIIIIII ,%o��of Call14 4'r. e--11 8 4 ��.�• 973�G:r tti�`: Sad Co���a•��. TATEN EVANS SOLAR DESIGNER PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUI CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2X.2911 DATE: 5/7/2021 PV RL 1 100 PV ROOF LAY PLAN 2X.2911 ELEVATION: C OPTION S): NONE SCALE. 1/16" = 1'-0" GARA E: FT 23 IVl0fDULES AT 7.820 kW DC LAYOUT 1 ELEVATICC OPTION(S): ONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 23 MODULES AT 7.820 kW DC LAYOUT 2 ELEVATIO OPTION(S): NONE SCALE: ############# GARAGE: RIGHT 23 MODULES AT 7.820 kW DC LAYOUT 3 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE BY BY ELEVATIO OPTION(S): NE SCALE: #### ####### GARAGE: RIGHT 23 MODULES AT 7.820 kW DC LAYOUT 4 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALE : 1 " PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV ,OVER PAGE, NOT TO EXCEED 3.8 AC CAPACITY, NOR TO BLOCK OR OVER ANY ROOF PLUMBING VENTILATION. z O U) w ry w Q 0 X a ry U U) W 0 ATEN EVANS .AR DESIGNER PV SYSTEM PROVIDED BY: 1.877.404.4 9 CA LI B/C46/C10/C-973756 HOME DEVELO ER: DR HORTON 2280 WARDLO CIRCLE, SUITE 100 CORONA, C 2880 THEE ES AT CARMELA LA QUINTA, CA PLAN: 2X.29 1 DATE: 5/7/2021 PV RL 2.0 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE STRING 2: 11 PV MODULES W/OPTIMIZERS STRING 1: 12 PV 2 1 MODULES W/OPTIMIZERS 23 PV MODULES PER I NVERTER = 7820 WATTS STC SolarEdge SE7600H-US Xk L NEMA3RJunction Box Photovoltaic System Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper) DC System Size (Watts) 7820 Tag Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size AC System Size (Watts) 7243 1 DC -to -DC Converter Output (PV Wire) 12 AWG 2(V+, V-) B/R Free Air N/A Total Module Count 23 1 EGC (Bare) 6 AWG 1 BARE Free Air N/A 2 DC -to -DC Converter Output (THWN-2) 12 AWG 2(V+, V-) B/R MC N/A 2 EGC (THWN-2) 12 AWG 1(GRN) MC N/A 3 Inverter Output (NM) 8 AWG 3(L1, L2, N) B/R/W Free Air N/A 3 EGC (NM) 10 AWG 11 BARE I Free Air N/A Square D DU222RB, 240V/60A, Unfused, NEMA3R Visible/Lockable'Knife' Disconnect B Rapid Shutdown Disconnect, Square D DU222RB, 240V/60A, Unfused, NEMA311 Lockable'Knife' Disconnect Conduit, Raceways, and J-Boxes (Labeled Every 10') and Installed within 3 ft of Rapid Shutdown Switch, Reflective, and shall be Reflective per 690.31(G)(3) & (4) placed on both Panel Exterior & next to Main Disconnect per WARNING:• • • a • SHUTDOWN POWER• • PV SYSTEM PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting Means with min. 3/8" black capitalized text on yellow background & 3/16" I WAt-11 r-1 1 .4 W 0 P_J kaw" Plaque / Directory at Service Equipment Location and Power Production System Disconnecting blacK Capltaiizea text on Wnite baCKgrouna per WIU.5b(L)(1)(a) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM, AND REDUCE; SHOCK HAZARD, IN ARRAY All Disconnecting Means - AC & DC Disconnect(s), Load Centers, and Combiner Panels per 690.13(B) & 690.15(D) AWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source output Connection, Adjacenl to Hack-ted breaker per IU5.12(13)(2)(3)(b) QWARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER.CURRENT PROTECTION DEVICE Dual Power Sources in Main Service Panel and Sub Panel(s) per 705.12(B)(3) QWARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM Poi nt of Interconnection, Load Side 705.12(13)(2)(3)(b) LIL2N Existing 240V/200AMIN. Service Panel, Single M Phase, with 200A Main Disconnect- NOTA CENTER FED - Minimum GEC size 4 AWG copper All AC Disconnecting Means - AC Disconnect(s), Combiner Panels, and Load Centers per 690.54 Inverter/Optimizer Specs Optimizer SolarEdge P370 DC Input Power 370 Watts DC Max. Input Voltage 60 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model SolarEdge SE760OH-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max Output Current 32 Amps DC Max Input Current 20 Amps Input Short Circuit Current 45 1 Amps Max Output Fault Current 40 A/20 ms Other Notes PV Module Rating @ STC Module Make/Model Hanwha Q.PEAK DUO BLK-G6+ 340w Max. Power -Point Current (Imp) 10.02 Amps Max. Power -Point Voltage (Vmp) 33.94 Volts Open -Circuit Voltage (Voc) 40.66 Volts Short -Circuit Current (Isc) 10.52 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 340 Watts Max. System Voltage 1000 (IEC)/1000 (UL) Voc Temperature Coefficient -0.27 1 AHJ Provided Data - Max Temp: 47 'C Min Temp: -7.4 °C Power Source(s) Output Calc: 705.12(B)(2)(3)(b) Main Bus Rating: 200 Amps Main Service Breaker Rating: 200 Amps PV Uprated Output Current: 40 Amps 200A + 40A <= 200 x 1.2; 240 <= 240A, OK • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. • All inverters installed in California are Rule 21 Utility interactive compliant. • Array grounding and bonding designed in compliance with 690.47(A). • Electrical terminations and connectors used in design are listed for use at a minimum of 75°C CITY OF LA Q U I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY J Conductor Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B) (3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit conductors use the ampacity in the 7S°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC -to -DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 2 Attic): DC -to -DC Converter Output: 12 AWG rated 30 A, 30 A x 0.65 x 1 = 19.5 A >= 15 A (Tag 3 Exterior): Inverter Output: 8 AWG rated 50 A, 50 A >= 40 A Voltage and OCPD Calculations (690.7, 690.9) PV Source Max Circuit Voltage: Module Voc x (1-(AT x Voc Coeff)) [art. 690.7(A)) Q.PEAK DUO BLK-G6+ 340w: 40.66 V x (1-((25 C - -7.4 C) x-0.27%)) = 44.22 V <= 60 V Inverter Output Circuit(s): Listed Output Current x 1.25 [art. 690.9(B)) Inverter 1: SE760OH-US Max Output = 32 A x 1.25 = 40 A <= 40 A (OCPD) System output current w/ continuous duty = 40 A <= 40 A (System OCPD) 1 MAXIMUM VOLTAGE ***V MAXIMUM CIRCUIT CURRENT ***A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC -TO -DC ***A CONVERTER (IF INSTALLED) 4 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 7 SITE PLACARD SHOWING ADDITIONAL POWER SOURCE AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL WARNING DUAL POWER SOURCE 10 SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING MAIN BREAKER DE -RATED 2 WARNING: PHOTOVOLTAIC POWER SOURCE 5 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN 8 ON THE LINE AND LOAD SIDES MAY BE ENERGIZED 10,TERMINALS DUE TO SOLAR CIRCUITS AMPS MAX ALLOWED IN THE OPEN POSITION DO NOT UPGRADE PV SYSTEM DISCONNECT PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OUTPUT CURRENT: *** A NOMINAL AC OPERATING VOLTAGE: *** V WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE 3 6 [� 9 ROOFTOP ARRAY 5 7) (11) IF APPLICABLE 1 4 6 8 10 6 INSIDE PANEL 2 3 8 6 8 6 8 6 8 10 9 9 8 EVERY 10' AND °.o'?° WITHIN V OF ELBOWS 9A DC M aDISCONNECT INSIDE ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT (WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) *** value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account, for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED PER ARTICLES 690 AND 70S AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8" WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. vJ Z 0 U) w .% `%0%%%11 to I I Hl/// a Ot Calixo ``. �� �.....� 0& VINO Cam° 973r TATEN EVANS SOLAR DESIGNER N W o � N ❑ Lo I- C) w Z Z O U u) 0 U < O w I- x w w a O I- J U C) Z W O J w w U < rn ❑ w 0- ❑ ::) w 1 PV,SYSTEM PROVIDED BY: VIV'alt.6010 " A SUI1run COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 2X.2911 I DATE: 5/7/2021 PV EE 1.0 REVISION #2 BCPR2020-0017 CITY OF LA QU I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08I20I2022 BY j P ADDED EXTERIOR AC DISCONNECT PLAN 3 2280 THE ESTATES LE, SUITE 92880 . 31874ml )UINTA, 31874m2 GENERAL NOTES: ELECTRICAL 1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4. SEE "PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. !. STRUCTURAL 2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE QRAIL SYSTEM BY QUICK MOUNT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5. GROUND SNOW LOAD = 0 psf 2.6. WIND SPEED = 130 mph 2.7. EXPOSURE CATEGORY = C SCOPE OF WORK 3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH THE ESTATES AT CARMELA 3.1. PLAN:3.2990 3.2. ELEVATIONS: A, B, C 4. BUILDING INFORMATION: 4.1. BUILDING OCCUPANCY GROUP: R3/U 4.2. CONSTRUCTION TYPE: VB INVERTER: SOLAREDGE SE7600H THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: HANWHA Q.PEAK DUO BLK-G6 340 THE ESTATES AT CARMELA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 22 MODULES 7.480kW DC / 6.928kW AC ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. C� .973 -7ecy coo TATEN EVANS SOLAR DESIGNER N w O N Q I- 0 Lo H U w Z Z O U 0 U Q O GOVERNING CODES: U) w ALL WORK SHALL CONFORM TO THE FOLLOWING CODES z x 1. 2019 CA BUILDING CODE 0 w 2. 2019 CA ENERGY CODE U) 3. 2019 CA ELECTRICAL CODE > O 4. 2019 CA FIRE CODE W 5. 2019 CA GREEN CODE z w 6. 2019 CA MECHANICAL CODE a 7. 2019 CA PLUMBING CODE a 8. 2019 CA RESIDENTIAL CODE 0 9. ANY OTHER LOCAL AMENDMENTS z Q J Q U ry H Z O U w - � a w o w SHEET INDEX: 0 a PV COVER COVER SHEET w 0- PV RL 2.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV SR 1.0 STRUCTURAL w PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER HANWHA Q.PEAK DUO BLK-G6 340 MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE �, JTHE* crv« PV SYSTEM PROVIDED BY: wvint.JUiar A sunrun COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 3.2990 DATE: 5/7/2021 PV COVER ELEVATION: A OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: A OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC LAYOUT 1 LAYOUT 4 ELEVATION: A OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC LAYOUT 2 LAYOUT 5 ELEVATION: A OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC ELEVATION: B OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 3 LAYOUT 6 ELEVATION: B OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 ELEVATION: C OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC ELEVATION: C OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: LEFT 22 MODULES AT 7.480 kW DC PV ROOF LAYOUTS PLAN 3.2990 FIRECODE OFFSET: ELEVATION: C OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 1 LAYOUT 4 ELEVATION: C OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 2 LAYOUT 5 ELEVATION: C OPTION(S): NONE SCALE: 1/16" = 1'-0" GARAGE: RIGHT 22 MODULES AT 7.480 kW DC LAYOUT 3 LAYOUT 6 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY j RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. U) z 0 U) w ry w Q 0 z 0 ry U U) w 0 w ry pt Ca/i/ ,, i f : _ ,wN •eggs MM• G � TATEN EVANS SOLAR DESIGNER CIVlL PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 3.2990 DATE: 5/7/2021 PV RL 2.0 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE Conduit, Raceways, and J-Boxes (Labeled Every 10') and Installed within 3 ft of Rapid Shutdown Switch, Reflective, and shall be Reflective per 690.31(G)(3) & (4) placed on both Panel Exterior & next to Main Disconnect per POWERWARNING: PHOTOVOLTAIC RAPID SHUTDOWN SWITCH • • PV SYSTEM PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting Means with min. 3/8" black capitalized text on yellow background & 3/16" I WAt-11 r-1 1 .4 W 0 PU kaw" Plaque / Directory at Service Equipment Location and Power Production System Disconnecting oiacK capltaiizea text on white DaCKgrouna per WIU.5b(C)(1)(a) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM, AND REDUCE; SHOCK HAZARD, IN ARRAY All Disconnecting Means - AC & DC Disconnect(s), Load Centers, and Combiner Panels per 690.13(B) & 690.15(D) AWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source Output Connection, Adjacent to BaCk-ted breaker per IU5.11(13)(1)(3)(b) QWARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER.CURRENT PROTECTION DEVICE Dual Power Sources in Main Service Panel and Sub Panel(s) per 705.12(B)(3) QWARNING DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM All AC Disconnecting Means - AC Disconnect(s), Combiner Panels, and Load Centers per 690.54 Inverter/Optimizer Specs Optimizer SolarEdge P370 DC Input Power 370 Watts DC Max. Input Voltage 60 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model SolarEdge SE760OH-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max Output Current 32 Amps DC Max Input Current 20 Amps Input Short Circuit Current 45 1 Amps Max Output Fault Current 40 A/20 ms Other Notes PV Module Rating @ STC Module Make/Model Hanwha Q.PEAK DUO BLK-G6+ 340w Max. Power -Point Current (Imp) 10.02 Amps Max. Power -Point Voltage (Vmp) 33.94 Volts Open -Circuit Voltage (Voc) 40.66 Volts Short -Circuit Current (Isc) 10.52 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 340 Watts Max. System Voltage 1000 (IEC)/1000 (UL) Voc Temperature Coefficient -0.27 %/C AHJ Provided Data - Max Temp: 47 'C Min Temp: -7.4 °C Power Source(s) Output Calk: 705.12(B)(2)(3)(b) Main Bus Rating: 200 Amps Main Service Breaker Rating: 200 Amps PV Uprated Output Current: 40 Amps 200A + 40A <= 200 x 1.2; 240 <= 240A, OK • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. • All inverters installed in California are Rule 21 Utility interactive compliant. • Array grounding and bonding designed in compliance with 690.47(A). • Electrical terminations and connectors used in design are listed for use at a minimum of 75°C CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE08/20/2022 BY -1 r MAXIMUM VOLTAGE ***V MAXIMUM CIRCUIT CURRENT ***A 1 MAX RATED OUTPUT CURRENT OF /I RAPID SHUTDOWN SWITCH THE CHARGE CONTROLLER OR DC -TO -DC ***A T FOR SOLAR PV SYSTEM CONVERTER (IF INSTALLED) Conductor Calculations Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B) (3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. Non-PV Circuit conductors use the ampacity in the 7S°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC -to -DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 2 Attic): DC -to -DC Converter Output: 12 AWG rated 30 A, 30 A x 0.65 x 1 = 19.5 A >= 15 A (Tag 3 Exterior): Inverter Output: 8 AWG rated 50 A, 50 A >= 40 A Voltage and OCPD Calculations (690.7, 690.9) PV Source Max Circuit Voltage: Module Voc x (1-(AT x Voc Coeff)) [art. 690.7(A)) Q.PEAK DUO BLK-G6+ 340w: 40.66 V x (1-((25 C - -7.4 C) x-0.27%)) = 44.22 V <= 60 V Inverter Output Circuit(s): Listed Output Current x 1.25 [art. 690.9(B)) Inverter 1: SE760OH-US Max Output = 32 A x 1.25 = 40 A <= 40 A (OCPD) System output current w/ continuous duty = 40 A <= 40 A (System OCPD) SITE PLACARD SHOWING ADDITIONAL POWER SOURCE 7 AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL WARNING 10 DUAL POWER SOURCE SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING MAIN BREAKER DE -RATED 2 WARNING: PHOTOVOLTAIC POWER SOURCE 5 SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND (�l DUE TO SOLAR CIRCUITS WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED AMPS MAX ALLOWED IN THE OPEN POSITION DO NOT UPGRADE PHOTOVOLTAIC AC DISCONNECT WARNING 3 PV SYSTEM DISCONNECT (�l MAXIMUM AC OUTPUT CURRENT: *** A [� POWER SOURCE OUTPUT CONNECTION NOMINAL AC OPERATING VOLTAGE: *** V 7 DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE ROOFTOP ARRAY 1 2 �o ., 3 8 o�. EVERY 10' AND �o ?0 WITHIN V OF ELBOWS 9 (,­6" 9� °9 DC Alj DISCONNECT INSIDE �I : S(sI 0 E CAI MOI 10) ( 9 7 11 IF APPLICABLE INSIDE 10 6 PANEL 9 8 M ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVIN I SULAK ME ILK VI51bLt/LULKAbLt A/L SUB PANEL MAIN SERVICE JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT (WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) *** value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account, for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED PER ARTICLES 690 AND 70S AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8" WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. vJ Z 0 U) LNU L.I_ TATEN EVANS SOLAR DESIGNER N Lu o � N ❑ Lo U w Z Z O U U) U < O Of w I- x w w O I- J U U Z W O J w w U < to ❑ w 0- ❑ D w 1 CoS\ONAL FN OPv T EZ 0 * NO. E 22210 7 ccIFCTA\GP�' �P q�OF CALIF 5/7 021 License Expires: 3/31/2022 PV SYSTEM PROVIDED BY: vllivalt.,bolar A SUf1run COMPANY 1.877.404.4129 CA LICENSE: B/C46/C 10/C36-973756 HOME DEVELOPER: DR HORTON 2280 WARDLOW CIRCLE, SUITE 100 CORONA, CA 92880 THE ESTATES AT CARMELA LA QUINTA, CA PLAN: 3.2990 I DATE: 5/7/2021 PV EE 1.0