Floresta TR 36762 BCPR2018-0002 (Plan 1, 1X, 2 & 3) SFD x4 - Energy DocumentsCERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 1 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
GENERAL INFORMATION
01 Project Name Plan 1
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)2302 15 Number of Zones 1
16 Slab Area (ft2)2302 17 Number of Stories 1
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)16.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CITY OF LA QUINTA
BUILDING DIVISION
APPROVED
FOR CONSTRUCTION
BY: DATE: 11/06/2018
BCPR2018-0002
FLORESTA SFD X 4: PLANS 1, 1X, 2 AND 3.
2016 CALIFORNIA BUILDING CODES.
VALID UNTIL EXPIRATION OF DESIGN
PROFESSIONALS STAMP OR UNTIL CODE
CHANGES, INCUDING SUPPLEMENTS AND
ERRATA.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 2 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 0.83 0.35 0.48 57.8%
Space Cooling 82.21 69.09 13.12 16.0%
IAQ Ventilation 1.06 1.06 0.00 0.0%
Water Heating 5.60 5.58 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 89.70 76.08 13.62 15.2%
Space Heating 0.83 0.80 0.03 3.6%
Space Cooling 82.21 73.16 9.05 11.0%
IAQ Ventilation 1.06 1.06 0.00 0.0%
Water Heating 5.60 5.58 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 89.70 80.60 9.10 10.1%
Space Heating 0.83 1.32 -0.49 -59.0%
Space Cooling 82.21 67.01 15.20 18.5%
IAQ Ventilation 1.06 1.06 0.00 0.0%
Water Heating 5.60 5.58 0.02 0.4%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 89.70 74.97 14.73 16.4%
Space Heating 0.83 0.62 0.21 25.3%
Space Cooling 82.21 65.98 16.23 19.7%
IAQ Ventilation 1.06 1.06 0.00 0.0%
Water Heating 5.60 5.58 0.02 0.4%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 89.70 73.24 16.46 18.4%
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 3 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 55.3 49.5 0.0 49.5
East 55.3 51.4 0.0 51.4
South 55.3 49.0 0.0 49.0
West 55.3 48.2 0.0 48.2
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 4 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1 2302 1 3 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2302 9.08 DHW Sys 1 n/a
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 5 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 121.9 40.5 90
Left Wall Home R-15+R-4 Wall 90 Left 308.6 54 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 113.6 8 90
Rear Wall Home R-15+R-4 Wall 180 Back 154.1 60 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 286.8 160 90
Right Wall Home R-15+R-4 Wall 270 Right 565.5 75 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 318.8 17.8 n/a
Left Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 144.4 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2272 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 321.6 147.3 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 319.7 80.7 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 173.7 0 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 670 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 6 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall 2x6 (Front-0)--------1 16.5 0.30 0.23 Insect Screen (default)
OP 2 Window Left Wall (Left-90)--------1 30.0 0.30 0.23 Insect Screen (default)
FRDR Window Left Wall (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall 2x6 (Left-90)--------1 8.0 0.30 0.23 Insect Screen (default)
OP 4 Window Rear Wall (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
FX Window Rear Wall (Back-180)--------1 30.0 0.28 0.25 Insect Screen (default)
SGD oh Window Rear Wall 2x6 (Back-180)8.0 8.0 1 64.0 0.42 0.23 Insect Screen (default)
SGD Window Rear Wall 2x6 (Back-180)--------1 96.0 0.42 0.23 Insect Screen (default)
OP 5 Window Right Wall (Right-270)--------1 75.0 0.30 0.23 Insect Screen (default)
FX 2 Window Front Exterior Wall (Front-0)--------1 19.3 0.28 0.25 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.14
Door 2 Front Interior Surface 17.8 0.50
Door 3 Front Exterior Wall 128.0 1.00
Door 4 Left Exterior Wall 64.0 1.00
Door 5 Left Exterior Wall 16.7 1.00
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 8.5 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 7 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2302 171 None 0.8 No
Slab 2 __Garage__670 90 None 0 No
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 8 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1393.5
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF 199,000 Btu/hr R-0/R-0 n/a 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 1 80 AFUE
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 9 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 53 0.25 Default 0 Required
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Calculation Date/Time:10:37, Tue, May 01, 2018 Page 10 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpF317.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:38:14
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Sean Allen
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-05-01 11:34:36
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-05-01 12:47:23
N/A
714-285-2900 7021
Sean Allen
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124640A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 1 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
GENERAL INFORMATION
01 Project Name Plan 1 Opt. Casita
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)2451 15 Number of Zones 1
16 Slab Area (ft2)2451 17 Number of Stories 1
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)18.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
BCPR2018-0002
CITY OF LA QUINTA
BUILDING DIVISION
APPROVED
FOR CONSTRUCTION
BY: DATE: 11/06/2018
FLORESTA SFD X 4: PLANS 1, 1X, 2 AND 3.
2016 CALIFORNIA BUILDING CODES.
VALID UNTIL EXPIRATION OF DESIGN
PROFESSIONALS STAMP OR UNTIL CODE
CHANGES, INCUDING SUPPLEMENTS AND
ERRATA.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 2 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.00 0.56 0.44 44.0%
Space Cooling 84.83 71.85 12.98 15.3%
IAQ Ventilation 1.02 1.02 0.00 0.0%
Water Heating 5.29 5.27 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 92.14 78.70 13.44 14.6%
Space Heating 1.00 0.91 0.09 9.0%
Space Cooling 84.83 74.97 9.86 11.6%
IAQ Ventilation 1.02 1.02 0.00 0.0%
Water Heating 5.29 5.27 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 92.14 82.17 9.97 10.8%
Space Heating 1.00 1.39 -0.39 -39.0%
Space Cooling 84.83 71.24 13.59 16.0%
IAQ Ventilation 1.02 1.02 0.00 0.0%
Water Heating 5.29 5.27 0.02 0.4%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 92.14 78.92 13.22 14.3%
Space Heating 1.00 0.86 0.14 14.0%
Space Cooling 84.83 68.50 16.33 19.3%
IAQ Ventilation 1.02 1.02 0.00 0.0%
Water Heating 5.29 5.27 0.02 0.4%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 92.14 75.65 16.49 17.9%
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 3 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 54.7 49.0 0.0 49.0
East 54.7 50.5 0.0 50.5
South 54.7 49.1 0.0 49.1
West 54.7 47.7 0.0 47.7
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 4 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1 Opt. Casita 2451 1 3 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2451 9.08 DHW Sys 1 n/a
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 5 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 251.6 51.3 90
Left Wall Home R-15+R-4 Wall 90 Left 308.6 54 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 205.1 51.3 90
Rear Wall Home R-15+R-4 Wall 180 Back 154.1 60 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 286.8 160 90
Right Wall Home R-15+R-4 Wall 270 Right 657 94.3 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 189 17.8 n/a
Left Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 144.4 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2421 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 190.7 128 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 227.4 16.7 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 81.4 0 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 521 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 6 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall 2x6 (Front-0)--------1 8.0 0.30 0.23 Insect Screen (default)
FX Window Front Wall 2x6 (Front-0)--------1 19.3 0.28 0.25 Insect Screen (default)
OP 2 Window Left Wall (Left-90)--------1 30.0 0.30 0.23 Insect Screen (default)
FRDR Window Left Wall (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall 2x6 (Left-90)--------1 27.3 0.30 0.23 Insect Screen (default)
FRDR 2 Window Left Wall 2x6 (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 4 Window Rear Wall (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
FX 2 Window Rear Wall (Back-180)--------1 30.0 0.28 0.25 Insect Screen (default)
SGD oh Window Rear Wall 2x6 (Back-180)8.0 8.0 1 64.0 0.42 0.23 Insect Screen (default)
SGD Window Rear Wall 2x6 (Back-180)--------1 96.0 0.42 0.23 Insect Screen (default)
OP 5 Window Right Wall (Right-270)--------1 94.3 0.30 0.23 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.50
Door 2 Front Interior Surface 17.8 0.50
Door 3 Front Exterior Wall 128.0 1.00
Door 4 Left Exterior Wall 16.7 1.00
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 8.5 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 7 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2451 205 None 0.8 No
Slab 2 __Garage__521 55 None 0 No
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 8 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1483.7
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF 199,000 Btu/hr R-0/R-0 n/a 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 9 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 55 0.25 Default 0 Required
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1 Opt. Casita Calculation Date/Time:10:44, Tue, May 01, 2018 Page 10 of 10
Calculation Description:Title 24 Analysis Input File Name:tmpCE35.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:45:50
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Sean Allen
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-05-01 11:41:39
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-05-01 12:47:23
N/A
714-285-2900 7021
Sean Allen
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124654A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 1 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
GENERAL INFORMATION
01 Project Name Plan 1X
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)3087 15 Number of Zones 1
16 Slab Area (ft2)2302 17 Number of Stories 2
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)14.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
BCPR2018-0002
CITY OF LA QUINTA
BUILDING DIVISION
APPROVED
FOR CONSTRUCTION
BY: DATE: 11/06/2018
FLORESTA SFD X 4: PLANS 1, 1X, 2 AND 3.
2016 CALIFORNIA BUILDING CODES.
VALID UNTIL EXPIRATION OF DESIGN
PROFESSIONALS STAMP OR UNTIL CODE
CHANGES, INCUDING SUPPLEMENTS AND
ERRATA.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 2 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.19 0.79 0.40 33.6%
Space Cooling 75.89 65.34 10.55 13.9%
IAQ Ventilation 1.13 1.13 0.00 0.0%
Water Heating 5.31 5.30 0.01 0.2%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 83.52 72.56 10.96 13.1%
Space Heating 1.19 1.15 0.04 3.4%
Space Cooling 75.89 66.41 9.48 12.5%
IAQ Ventilation 1.13 1.13 0.00 0.0%
Water Heating 5.31 5.30 0.01 0.2%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 83.52 73.99 9.53 11.4%
Space Heating 1.19 1.53 -0.34 -28.6%
Space Cooling 75.89 64.13 11.76 15.5%
IAQ Ventilation 1.13 1.13 0.00 0.0%
Water Heating 5.31 5.30 0.01 0.2%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 83.52 72.09 11.43 13.7%
Space Heating 1.19 1.00 0.19 16.0%
Space Cooling 75.89 61.25 14.64 19.3%
IAQ Ventilation 1.13 1.13 0.00 0.0%
Water Heating 5.31 5.30 0.01 0.2%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 83.52 68.68 14.84 17.8%
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 3 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 53.2 48.4 0.0 48.4
East 53.2 49.0 0.0 49.0
South 53.2 48.2 0.0 48.2
West 53.2 46.7 0.0 46.7
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 4 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1X 3087 1 5 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 3087 9.08 DHW Sys 1 n/a
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 5 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 121.9 40.5 90
Left Wall Home R-15+R-4 Wall 90 Left 308.6 54 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 113.6 8 90
Rear Wall Home R-15+R-4 Wall 180 Back 154.1 60 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 286.8 160 90
Right Wall Home R-15+R-4 Wall 270 Right 565.5 75 90
Front Wall Home R-15+R-4 Wall 0 Front 102.4 6 90
Left Wall 2 Home R-15+R-4 Wall 90 Left 307.1 30 90
Right Wall 2 Home R-15+R-4 Wall 270 Right 307.1 30 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 318.8 17.8 n/a
Left Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 144.4 0 n/a
Front Kneewall Home>>Attic Home R-15 Wall n/a n/a 237.57 0 n/a
Rear Kneewall Home>>Attic Home R-15 Wall n/a n/a 340.2 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2401 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Raised Floor Home R-19 Floor No Crawlspace n/a n/a 38 n/a n/a
Over Garage Home>>__Garage__R-19 Floor No Crawlspace1 n/a n/a 91 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 321.6 147.3 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 319.7 80.7 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 173.7 0 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 521 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 6 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall 2x6 (Front-0)--------1 16.5 0.30 0.23 Insect Screen (default)
OP 2 Window Left Wall (Left-90)--------1 30.0 0.30 0.23 Insect Screen (default)
FRDR Window Left Wall (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall 2x6 (Left-90)--------1 8.0 0.30 0.23 Insect Screen (default)
OP 4 Window Rear Wall (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
FX Window Rear Wall (Back-180)--------1 30.0 0.28 0.25 Insect Screen (default)
SGD oh Window Rear Wall 2x6 (Back-180)8.0 8.0 1 64.0 0.42 0.23 Insect Screen (default)
SGD Window Rear Wall 2x6 (Back-180)--------1 96.0 0.42 0.23 Insect Screen (default)
OP 5 Window Right Wall (Right-270)--------1 75.0 0.30 0.23 Insect Screen (default)
FX 2 Window Front Wall (Front-0)--------1 6.0 0.28 0.25 Insect Screen (default)
OP 6 Window Left Wall 2 (Left-90)--------1 30.0 0.30 0.23 Insect Screen (default)
OP 7 Window Right Wall 2 (Right-270)--------1 30.0 0.30 0.23 Insect Screen (default)
FX 3 Window Front Exterior Wall (Front-0)--------1 19.3 0.28 0.25 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.50
Door 2 Front Interior Surface 17.8 0.50
Door 3 Front Exterior Wall 128.0 1.00
Door 4 Left Exterior Wall 64.0 1.00
Door 5 Left Exterior Wall 16.7 1.00
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 8.5 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 7 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
R-19 Floor No Crawlspace Exterior Floors Wood Framed Floor 2x6 @ 16 in. O.C.
R 19 in 5-1/2 in.
cavity (R-18)0.052
•Floor Surface: Carpeted
•Floor Deck: Wood Siding/sheathing/decking
•Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6
R-19 Floor No Crawlspace1 Interior Floors Wood Framed Floor 2x6 @ 16 in. O.C.
R 19 in 5-1/2 in.
cavity (R-18)0.049
•Floor Surface: Carpeted
•Floor Deck: Wood Siding/sheathing/decking
•Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6
•Ceiling Below Finish: Gypsum Board
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 8 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2302 171 None 0.8 No
Slab 2 __Garage__612 90 None 0 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1868.7
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF <= 200 kBtu/hr R-0/R-0 0 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 9 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 10 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 76 0.25 Default 0 Required
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Calculation Date/Time:11:49, Thu, Sep 06, 2018 Page 11 of 11
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:51:17
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-09-06 14:12:08
N/A
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-09-06 14:42:39
N/A
714-285-2900 7021
Cristela Lujan
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124660C-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 1 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
GENERAL INFORMATION
01 Project Name Plan 1X Opt. Casita
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)3236 15 Number of Zones 1
16 Slab Area (ft2)2451 17 Number of Stories 2
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)15.8%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
BCPR2018-0002
CITY OF LA QUINTA
BUILDING DIVISION
APPROVED
FOR CONSTRUCTION
BY: DATE: 11/06/2018
FLORESTA SFD X 4: PLANS 1, 1X, 2 AND 3.
2016 CALIFORNIA BUILDING CODES.
VALID UNTIL EXPIRATION OF DESIGN
PROFESSIONALS STAMP OR UNTIL CODE
CHANGES, INCUDING SUPPLEMENTS AND
ERRATA.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 2 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.32 0.93 0.39 29.5%
Space Cooling 77.89 67.02 10.87 14.0%
IAQ Ventilation 1.10 1.10 0.00 0.0%
Water Heating 5.07 5.05 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 85.38 74.10 11.28 13.2%
Space Heating 1.32 1.16 0.16 12.1%
Space Cooling 77.89 67.16 10.73 13.8%
IAQ Ventilation 1.10 1.10 0.00 0.0%
Water Heating 5.07 5.05 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 85.38 74.47 10.91 12.8%
Space Heating 1.32 1.55 -0.23 -17.4%
Space Cooling 77.89 66.68 11.21 14.4%
IAQ Ventilation 1.10 1.10 0.00 0.0%
Water Heating 5.07 5.05 0.02 0.4%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 85.38 74.38 11.00 12.9%
Space Heating 1.32 1.12 0.20 15.2%
Space Cooling 77.89 62.50 15.39 19.8%
IAQ Ventilation 1.10 1.10 0.00 0.0%
Water Heating 5.07 5.05 0.02 0.4%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 85.38 69.77 15.61 18.3%
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 3 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 52.5 47.6 0.0 47.6
East 52.5 47.8 0.0 47.8
South 52.5 47.8 0.0 47.8
West 52.5 45.7 0.0 45.7
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 4 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1X Opt. Casita 3236 1 5 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 3236 9.08 DHW Sys 1 n/a
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 5 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 251.6 51.3 90
Left Wall Home R-15+R-4 Wall 90 Left 308.7 54 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 205.2 51.3 90
Rear Wall Home R-15+R-4 Wall 180 Back 154.1 60 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 286.8 160 90
Right Wall Home R-15+R-4 Wall 270 Right 657.1 94.3 90
Front Wall Home R-15+R-4 Wall 0 Front 102.4 6 90
Left Wall 2 Home R-15+R-4 Wall 90 Left 306.3 30 90
Right Wall 2 Home R-15+R-4 Wall 270 Right 306.4 30 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 189 17.8 n/a
Left Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 144.4 0 n/a
Front Kneewall Home>>Attic Home R-15 Wall n/a n/a 236.98 0 n/a
Rear Kneewall Home>>Attic Home R-15 Wall n/a n/a 339.36 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2550 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Raised Floor Home R-19 Floor No Crawlspace n/a n/a 38 n/a n/a
Over Garage Home>>__Garage__R-19 Floor No Crawlspace1 n/a n/a 91 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 190.7 128 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 227.4 16.7 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 81.4 0 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 372 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 6 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall 2x6 (Front-0)--------1 8.0 0.30 0.23 Insect Screen (default)
FX Window Front Wall 2x6 (Front-0)--------1 19.3 0.28 0.25 Insect Screen (default)
OP 2 Window Left Wall (Left-90)--------1 30.0 0.30 0.23 Insect Screen (default)
FRDR Window Left Wall (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
FRDR 2 Window Left Wall 2x6 (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall 2x6 (Left-90)--------1 8.0 0.30 0.23 Insect Screen (default)
OP 4 Window Left Wall 2x6 (Left-90)--------1 19.3 0.30 0.23 Insect Screen (default)
OP 5 Window Rear Wall (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
FX 2 Window Rear Wall (Back-180)--------1 30.0 0.28 0.25 Insect Screen (default)
SGD oh Window Rear Wall 2x6 (Back-180)8.0 8.0 1 64.0 0.42 0.23 Insect Screen (default)
SGD Window Rear Wall 2x6 (Back-180)--------1 96.0 0.42 0.23 Insect Screen (default)
OP 6 Window Right Wall (Right-270)--------1 75.0 0.30 0.23 Insect Screen (default)
OP 7 Window Right Wall (Right-270)--------1 19.3 0.30 0.23 Insect Screen (default)
FX 3 Window Front Wall (Front-0)--------1 6.0 0.28 0.25 Insect Screen (default)
OP 8 Window Left Wall 2 (Left-90)--------1 30.0 0.30 0.23 Insect Screen (default)
OP 9 Window Right Wall 2 (Right-270)--------1 30.0 0.30 0.23 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.50
Door 2 Front Interior Surface 17.8 0.50
Door 3 Front Exterior Wall 128.0 1.00
Door 4 Left Exterior Wall 16.7 1.00
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 7 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 8.5 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 8 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
R-19 Floor No Crawlspace Exterior Floors Wood Framed Floor 2x6 @ 16 in. O.C.
R 19 in 5-1/2 in.
cavity (R-18)0.052
•Floor Surface: Carpeted
•Floor Deck: Wood Siding/sheathing/decking
•Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6
R-19 Floor No Crawlspace1 Interior Floors Wood Framed Floor 2x6 @ 16 in. O.C.
R 19 in 5-1/2 in.
cavity (R-18)0.049
•Floor Surface: Carpeted
•Floor Deck: Wood Siding/sheathing/decking
•Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6
•Ceiling Below Finish: Gypsum Board
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 9 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2451 205 None 0.8 No
Slab 2 __Garage__463 55 None 0 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1958.9
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF <= 200 kBtu/hr R-0/R-0 0 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 10 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 11 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 77 0.25 Default 0 Required
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 1X Opt. Casita Calculation Date/Time:11:54, Thu, Sep 06, 2018 Page 12 of 12
Calculation Description:Title 24 Analysis Input File Name:Beazer_Floresta_Plan 1X Opt. Casita.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-06 11:56:42
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-09-06 14:15:21
R16-18-20136
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-09-06 14:42:39
N/A
714-285-2900 7021
Cristela Lujan
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124666B-000-000-0000000-0000 2018-09-06 14:42:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 1 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
GENERAL INFORMATION
01 Project Name Plan 2
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)2467 15 Number of Zones 1
16 Slab Area (ft2)2467 17 Number of Stories 1
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)21.3%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 2 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.39 1.37 0.02 1.4%
Space Cooling 93.45 77.05 16.40 17.5%
IAQ Ventilation 1.16 1.16 0.00 0.0%
Water Heating 5.76 5.74 0.02 0.3%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 101.76 85.32 16.44 16.2%
Space Heating 1.39 1.32 0.07 5.0%
Space Cooling 93.45 79.43 14.02 15.0%
IAQ Ventilation 1.16 1.16 0.00 0.0%
Water Heating 5.76 5.74 0.02 0.3%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 101.76 87.65 14.11 13.9%
Space Heating 1.39 1.85 -0.46 -33.1%
Space Cooling 93.45 80.55 12.90 13.8%
IAQ Ventilation 1.16 1.16 0.00 0.0%
Water Heating 5.76 5.74 0.02 0.3%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 101.76 89.30 12.46 12.2%
Space Heating 1.39 1.75 -0.36 -25.9%
Space Cooling 93.45 74.25 19.20 20.5%
IAQ Ventilation 1.16 1.16 0.00 0.0%
Water Heating 5.76 5.74 0.02 0.3%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 101.76 82.90 18.86 18.5%
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 3 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 57.0 50.4 0.0 50.4
East 57.0 51.3 0.0 51.3
South 57.0 52.0 0.0 52.0
West 57.0 49.4 0.0 49.4
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 4 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2 2467 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2467 9.08 DHW Sys 1 n/a
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 5 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall Home R-15+R-4 Wall 0 Front 102.7 20 90
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 206.2 61 90
Left Wall Home R-15+R-4 Wall 90 Left 761.6 131.5 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 68.2 48 90
Rear Wall Home R-15+R-4 Wall 180 Back 206.2 53 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 288 142 90
Right Wall Home R-15+R-4 Wall 270 Right 445.5 25 90
Right Wall 2x6 Home R-21+R-4 Wall 270 Right 307.1 69 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 135 17.8 n/a
Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 54.7 0 n/a
Right Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 77.2 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2437 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 191.4 128 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 193.3 0 90
Rear Exterior Wall __Garage__R-0 Wall 180 Back 4.9 0 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 271.2 16.7 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 514 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 6 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall (Front-0)--------1 20.0 0.30 0.23 Insect Screen (default)
OP 2 Window Front Wall 2x6 (Front-0)--------1 37.0 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall (Left-90)--------1 131.5 0.30 0.23 Insect Screen (default)
SGD oh Window Left Wall 2x6 (Left-90)6.0 8.0 1 48.0 0.42 0.23 Insect Screen (default)
OP 4 Window Rear Wall (Back-180)--------1 53.0 0.30 0.23 Insect Screen (default)
OP 5 Window Rear Wall 2x6 (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
SGD oh 2 Window Rear Wall 2x6 (Back-180)14.0 8.0 1 112.0 0.42 0.23 Insect Screen (default)
OP 6 Window Right Wall (Right-270)--------1 25.0 0.30 0.23 Insect Screen (default)
OP 7 Window Right Wall 2x6 (Right-270)--------1 45.0 0.30 0.23 Insect Screen (default)
FRDR oh Window Right Wall 2x6 (Right-270)3.0 8.0 1 24.0 0.30 0.23 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.50
Door 2 Front Interior Surface 17.8 0.50
Door 3 Front Exterior Wall 128.0 1.00
Door 4 Right Exterior Wall 16.7 1.00
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 16 1 3 3 0 0 0 0 0 0 0 0 0
SGD oh 2 9 1 3 3 0 0 0 0 0 0 0 0 0
FRDR oh 16 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 7 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 8 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2467 263 None 0.8 No
Slab 2 __Garage__514 73 None 0 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1493.4
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF 199,000 Btu/hr R-0/R-0 n/a 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 9 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 10 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 62 0.25 Default 0 Required
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 2 Calculation Date/Time:10:53, Tue, May 01, 2018 Page 11 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp66DA.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:55:17
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Sean Allen
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-05-01 11:57:29
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-05-01 12:47:23
N/A
714-285-2900 7021
Sean Allen
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124674A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 1 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
GENERAL INFORMATION
01 Project Name Plan 3
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)2497 15 Number of Zones 1
16 Slab Area (ft2)2497 17 Number of Stories 1
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)20.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 2 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.00 0.77 0.23 23.0%
Space Cooling 89.23 71.36 17.87 20.0%
IAQ Ventilation 1.15 1.15 0.00 0.0%
Water Heating 5.70 5.68 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 97.08 78.96 18.12 18.7%
Space Heating 1.00 0.81 0.19 19.0%
Space Cooling 89.23 77.32 11.91 13.3%
IAQ Ventilation 1.15 1.15 0.00 0.0%
Water Heating 5.70 5.68 0.02 0.4%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 97.08 84.96 12.12 12.5%
Space Heating 1.00 1.67 -0.67 -67.0%
Space Cooling 89.23 76.24 12.99 14.6%
IAQ Ventilation 1.15 1.15 0.00 0.0%
Water Heating 5.70 5.68 0.02 0.4%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 97.08 84.74 12.34 12.7%
Space Heating 1.00 1.47 -0.47 -47.0%
Space Cooling 89.23 69.98 19.25 21.6%
IAQ Ventilation 1.15 1.15 0.00 0.0%
Water Heating 5.70 5.68 0.02 0.4%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 97.08 78.28 18.80 19.4%
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 3 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 57.3 49.7 0.0 49.7
East 57.3 52.2 0.0 52.2
South 57.3 52.1 0.0 52.1
West 57.3 49.4 0.0 49.4
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 4 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3 2497 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2497 9.08 DHW Sys 1 n/a
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 5 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall Home R-15+R-4 Wall 0 Front 110.3 30 90
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 45 24 90
Left Wall Home R-15+R-4 Wall 90 Left 501 94.5 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 197.2 119 90
Rear Wall Home R-15+R-4 Wall 180 Back 294.4 176 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 155.6 60 90
Right Wall Home R-15+R-4 Wall 270 Right 376.5 20 90
Right Wall 2x6 Home R-21+R-4 Wall 270 Right 133.8 15 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 247.9 17.8 n/a
Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 49.5 0 n/a
Right Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 187.8 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2467 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 315.9 169.3 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 93.4 0 90
Rear Exterior Wall __Garage__R-0 Wall 180 Back 15.9 0 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 282.9 80.7 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 572 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 6 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall (Front-0)--------1 30.0 0.30 0.23 Insect Screen (default)
OP 2 Window Left Wall (Left-90)--------1 94.5 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall 2x6 (Left-90)--------1 15.0 0.30 0.23 Insect Screen (default)
SGD oh Window Left Wall 2x6 (Left-90)10.0 8.0 1 80.0 0.42 0.23 Insect Screen (default)
FRDR Window Left Wall 2x6 (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 4 Window Rear Wall (Back-180)--------1 96.0 0.30 0.23 Insect Screen (default)
SGD oh 2 Window Rear Wall (Back-180)10.0 8.0 1 80.0 0.42 0.23 Insect Screen (default)
OP 5 Window Rear Wall 2x6 (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
FX Window Rear Wall 2x6 (Back-180)--------1 30.0 0.28 0.25 Insect Screen (default)
OP 6 Window Right Wall (Right-270)--------1 20.0 0.30 0.23 Insect Screen (default)
OP 7 Window Right Wall 2x6 (Right-270)--------1 15.0 0.30 0.23 Insect Screen (default)
FX 2 Window Front Exterior Wall (Front-0)--------1 41.3 0.28 0.25 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.50
Door 2 Front Interior Surface 17.8 0.50
Door 3 Front Exterior Wall 128.0 1.00
Door 4 Right Exterior Wall 16.7 1.00
Door 5 Right Exterior Wall 64.0 1.00
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 12 1 3 3 0 0 0 0 0 0 0 0 0
SGD oh 2 16 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 7 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 8 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2497 200 None 0.8 No
Slab 2 __Garage__572 78 None 0 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1511.5
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF 199,000 Btu/hr R-0/R-0 n/a 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 9 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 10 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 62 0.25 Default 0 Required
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Calculation Date/Time:10:57, Tue, May 01, 2018 Page 11 of 11
Calculation Description:Title 24 Analysis Input File Name:tmpEA06.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 10:59:10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Sean Allen
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-05-01 12:08:43
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-05-01 12:47:23
N/A
714-285-2900 7021
Sean Allen
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124694A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 1 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
GENERAL INFORMATION
01 Project Name Plan 3 Opt. Casita
02 Calculation Description Title 24 Analysis
03 Project Location Floresta
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)2653 15 Number of Zones 1
16 Slab Area (ft2)2653 17 Number of Stories 1
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)21.5%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 2 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 1.23 1.06 0.17 13.8%
Space Cooling 90.43 72.68 17.75 19.6%
IAQ Ventilation 1.11 1.11 0.00 0.0%
Water Heating 5.36 5.35 0.01 0.2%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 98.13 80.20 17.93 18.3%
Space Heating 1.23 1.00 0.23 18.7%
Space Cooling 90.43 78.73 11.70 12.9%
IAQ Ventilation 1.11 1.11 0.00 0.0%
Water Heating 5.36 5.35 0.01 0.2%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 98.13 86.19 11.94 12.2%
Space Heating 1.23 1.62 -0.39 -31.7%
Space Cooling 90.43 78.18 12.25 13.5%
IAQ Ventilation 1.11 1.11 0.00 0.0%
Water Heating 5.36 5.35 0.01 0.2%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 98.13 86.26 11.87 12.1%
Space Heating 1.23 1.66 -0.43 -35.0%
Space Cooling 90.43 73.14 17.29 19.1%
IAQ Ventilation 1.11 1.11 0.00 0.0%
Water Heating 5.36 5.35 0.01 0.2%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 98.13 81.26 16.87 17.2%
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 3 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 56.9 49.4 0.0 49.4
East 56.9 51.9 0.0 51.9
South 56.9 52.0 0.0 52.0
West 56.9 49.9 0.0 49.9
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Insulation below roof deck
•Window overhangs and/or fins
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 4 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•Building Envelope Air Leakage
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3 Opt. Casita 2653 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2653 9.08 DHW Sys 1 n/a
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 5 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Front Wall Home R-15+R-4 Wall 0 Front 110.3 71.3 90
Front Wall 2x6 Home R-21+R-4 Wall 0 Front 169.8 24 90
Left Wall Home R-15+R-4 Wall 90 Left 501 94.5 90
Left Wall 2x6 Home R-21+R-4 Wall 90 Left 289.9 143 90
Rear Wall Home R-15+R-4 Wall 180 Back 310.1 176 90
Rear Wall 2x6 Home R-21+R-4 Wall 180 Back 155.6 60 90
Right Wall Home R-15+R-4 Wall 270 Right 469.1 35 90
Right Wall 2x6 Home R-21+R-4 Wall 270 Right 133.8 15 90
Front Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 138.8 17.8 n/a
Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 49.5 0 n/a
Right Interior Surface Home>>__Garage__Garage R-15 Wall n/a n/a 187.8 0 n/a
Roof Home R-38+R-15 BD n/a n/a 2623 n/a n/a
Furnace Home R-30 Roof Attic n/a n/a 30 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 190 128 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 189.5 16.7 90
Roof 2 __Garage__R-0 Roof Attic n/a n/a 429 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Ventilated 4 0.1 0.85 No No
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.1 0.85 No No
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 6 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
OP Window Front Wall (Front-0)--------1 30.0 0.30 0.23 Insect Screen (default)
FX Window Front Wall (Front-0)--------1 41.3 0.28 0.25 Insect Screen (default)
OP 2 Window Left Wall (Left-90)--------1 94.5 0.30 0.23 Insect Screen (default)
OP 3 Window Left Wall 2x6 (Left-90)--------1 15.0 0.30 0.23 Insect Screen (default)
SGD oh Window Left Wall 2x6 (Left-90)10.0 8.0 1 80.0 0.42 0.23 Insect Screen (default)
FRDR Window Left Wall 2x6 (Left-90)--------1 24.0 0.30 0.23 Insect Screen (default)
OP 4 Window Rear Wall (Back-180)--------1 96.0 0.30 0.23 Insect Screen (default)
SGD oh 2 Window Rear Wall (Back-180)10.0 8.0 1 80.0 0.42 0.23 Insect Screen (default)
OP 5 Window Rear Wall 2x6 (Back-180)--------1 30.0 0.30 0.23 Insect Screen (default)
FX 2 Window Rear Wall 2x6 (Back-180)--------1 30.0 0.28 0.25 Insect Screen (default)
OP 6 Window Right Wall (Right-270)--------1 35.0 0.30 0.23 Insect Screen (default)
OP 7 Window Right Wall 2x6 (Right-270)--------1 15.0 0.30 0.23 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 2x6 24.0 0.50
Door 2 Left Wall 2x6 24.0 0.50
Door 3 Front Interior Surface 17.8 0.50
Door 4 Front Exterior Wall 128.0 1.00
Door 5 Right Exterior Wall 16.7 1.00
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD oh 12 1 3 3 0 0 0 0 0 0 0 0 0
SGD oh 2 16 1 3 3 0 0 0 0 0 0 0 0 0
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 7 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.361
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Exterior Finish: 3 Coat Stucco
R-0 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.none 0.481
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.400
•Cavity / Frame: no insul. / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Attic RoofHome Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 15 0.065
•Around Roof Joists: R-2.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
R-15+R-4 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
R-21+R-4 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.051
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: R4 Sheathing
•Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.R 15 0.086
•Inside Finish: Gypsum Board
•Cavity / Frame: R-15 / 2x4
•Other Side Finish: Gypsum Board
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Other Side Finish: Gypsum Board
R-38+R-15 BD
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-30 Roof Attic
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 8 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab Home 2653 236 None 0.8 No
Slab 2 __Garage__429 42 None 0 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1605.9
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas
Consumer
Instantaneous
(UEF)
1 0 0.81 UEF 199,000 Btu/hr R-0/R-0 n/a 8 GPM n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC System1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 2 80 AFUE
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 9 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 6 Attic None Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 10 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 64 0.25 Default 0 Required
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Plan 3 Opt. Casita Calculation Date/Time:11:04, Tue, May 01, 2018 Page 11 of 11
Calculation Description:Title 24 Analysis Input File Name:tmp421A.tmp.xml
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-05-01 11:06:08
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Sean Allen
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2018-05-01 12:17:14
702-365-8080
Laura Jew
Beazer Homes
1800 East Imperial Highway, Suite 200
Brea, CA 92821
2018-05-01 12:47:23
N/A
714-285-2900 7021
Sean Allen
Laura Jew
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010124742A-000-000-0000000-0000 2018-05-01 12:47:23 CalCERTS inc.