FRSS2024-0133BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 07/25/2024
ISSUED DATE: 07/29/2024
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Fire Sprinkler System - Residential - 13D
78410 HERITAGE WAY
FRSS2024-0133
643240033
$0.00
34
Owner:
Applicant:Jamie Biship
705 E HARRISON ST STE 200, CORONA, CA
92879
Contractor:Jamie Biship / 684600
705 E HARRISON ST STE 200, CORONA, CA
92879
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 3/14/25 11:40 am Page 1 of 4
Permit Type:
Permit Number:
Property Address:
Fire Sprinkler System - Residential - 13D
FRSS2024-0133
78410 HERITAGE WAY
BUILDING PERMIT
construction lender preliminary notice from that duty.
Printed: 3/14/25 11:40 am Page 2 of 4
Permit Type:
Permit Number:
Property Address:
Fire Sprinkler System - Residential - 13D
FRSS2024-0133
78410 HERITAGE WAY
BUILDING PERMIT
Pointe Happy (Phase 4) / Tract# 31348 / Plan 1 / Lot 34 78410 Heritage Way
Use of Permit
Construction Details
27Number of Sprinkler
Heads
3525Building Square Feet -
Protected
R-3: 1 & 2 Family
Dwellings
Building/Unit
Occupancy
Classification(s)
Zoning General Plan City Limits
Pointe HAppySubdivision Name 34Lot Number Lot Size
87927Centerlines Truck Routes Legal Description
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
INV-00008176 $8.00 Technology Enhancement Fee $8.00
$4.78 Credit Card Convenience Fee $4.78
$183.00 Fire - Sprinkler System - Tract Production Home $183.00
$195.78 $195.78 Total for Invoice INV-00008176
NOT INVOICED $0.00 Digital Archiving and Records Management Fee $23.00
$23.00 $0.00 Total for Invoice NOT INVOICED
Grand Total for Permit $218.78 $195.78
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Issue Permit v.1 07/25/2024 14:05 07/25/2024 14:05
Verify & Invoice Fees v.1 Generic Action 07/25/2024 14:05
Ready to Issue v.1 Generic Action 07/25/2024 14:05
Fire Inspections v.1 08/01/2024 11:30 12/06/2024 11:56
OH Rough Piping (RES) v.1 Inspection 08/01/2024 11:30 08/09/2024 13:23
OH Hydro (Res) v.1 Inspection 08/01/2024 11:31 08/09/2024 13:24
Fire Sprinkler Final 13D v.1 Inspection 11/26/2024 13:33 12/06/2024 11:56
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
Printed: 3/14/25 11:40 am Page 3 of 4
Permit Type:
Permit Number:
Property Address:
Fire Sprinkler System - Residential - 13D
FRSS2024-0133
78410 HERITAGE WAY
BUILDING PERMIT
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 3/14/25 11:40 am Page 4 of 4
*FOR REFERENCE ONLY
ELEV.-2'
FINISH GRADE
ELEV.-2'
0'ELEV.
2'
¾"
METER
MASTER METER
PSI LOSS
ELEV.
-2'
MAIN
CITY
ELEV.
5
4
2 1
TO DOMESTIC WATER
CONTROL VALVE FOR DOMESTIC
5 GPM ALLOWANCE
10.2
PVC
MAX
1¼"
70'
COPPER K
MAX
1"
30'
PRESSURE REGULATOR
TO BE SET AT 60 PSI
COPPER L1¼"
OCCUPANCY:
CONSTRUCTION:
STORIES:
FIRE SPRINKLER SYSTEM:
DESIGNED AND INSTALLED PER 2016 NFPA 13D ALL
RESIDENTIAL WITH A .05 DENSITY WITHIN AREAS.
1
V-B
R3 / U
CONCEALED RES. PENDENT SPRINKLER
RISER LOCATION (PER DETAIL)
NODE POINT FOR CALCULATION
RES. PENDENT SPRINKLER
CHANGE IN ELEVATION
XX
BUILDING AREA:3,525 SQFT.
APPROVAL STAMP
LA QUINTA, CA.
AHJ: LA QUINTA FIRE DEPARTMENT
PLAN 1
GENERAL NOTES
LICENSE NO. 684600
705 E. HARRISON ST., SUITE 200
CORONA, CA 92879
PH - 800-915-3473
FAX - 951-272-2535
CUSTOM, TRACT, MULTI-FAMILY
AND COMMERCIAL
DESIGN, C.P.INEERING AND
INSTALLATION
N.T.S.
IF SHEET IS LESS THAN
SHEET FP1 OF FP3
SIZE - 24" X 36"
SHEET ID
24" X 36" IT IS A REDUCED
SCALE
PRINT SCALE
REDUCE ACCORDINGLY
NO
.
DA
T
E
RE
V
I
S
I
O
N
1 2 3 4 5
CLASSIFICATION
C-16
LICENSE NO.
684600
F
I
RE
PR O T E C T I ON CO
N
T
R
A
C
T
O
RF
S
T
A
TE
OF C A L I F O RN
IA
The recipient of these plans
hereby acknowledges that all
plans, details, specifications or
methods of installation
contained in this set of plans is
the sole property of Fire
Sprinkler Systems, Inc. and
that any use of this set of plans
is prohibited and is a violation
of copyright laws without first
receiving permission from Fire
Sprinkler Systems.
DRAWN BY:
32288
8/18/22
JOB NO:
DATE:
C.P.
WI
L
L
I
A
M
S
H
O
M
E
S
BY
:
LA
Q
U
I
N
T
A
,
C
A
.
GE
N
E
R
A
L
N
O
T
E
S
A
N
D
L
E
G
E
N
D
13D GENERAL NOTES
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.AUTOMATIC FIRE SPRINKLER SYSTEM HAS BEEN DESIGNED TO BE
INSTALLED IN ACCORDANCE WITH NFPA 13D, 2016 EDITION AND THE
REQUIREMENTS OF LA QUINTA FIRE DEPARTMENT.
THIS SPRINKLER SYSTEM SHALL BE TESTED AND INSPECTED BOTH
THE ROUGH AND FINAL INSPECTION PRIOR TO OCCUPANCY BEING
GRANTED. THE JURISDICTIONAL FIRE PREVENTION OFFICE WILL BE
NOTIFIED A MINIMUM OF TWO WORKING DAYS IN ADVANCE OF THE
REQUESTED INSPECTION.
THE INSTALLER SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS,
NOTCHING, DRILLING, OR OTHERWISE PENETRATING STRUCTURAL
MEMBERS SHALL BE IN ACCORDANCE WITH CALIFORNIA BUILDING CODE.
TYPE OF PLASTIC PIPE TO BE CPVC MANUFACTURED BY BLAZEMASTER
U.L. LISTED.
ALL VALVES SHALL HAVE A PERMANENTLY AFFIXED SIGN INDICATING
IT'S FUNCTION.
PIPE SHALL BE HUNG FROM STRUCTURAL MEMBER PER THE UNIFORM
PLUMBING CODE. PIPE CLAMPS AND SCREWS ARE MANUFACTURED BY
AFCON MFG. ARE U.L. LISTED AND ARE INSTALLED ACCORDING TO THE
HANGING REQUIREMENTS IN THEIR TECHNICAL DATA (SEE DETAIL).
THE SPACING AND LOCATION OF SPRINKLERS SHALL CONFORM WITH
THE MANUFACTURES REQUIREMENTS AND THOSE CONTAINED IN
NFPA 13D, 2016 EDITION.
IF REQUIRED BY A.H.J. THE ALARM INDICATING DEVICE SHALL BE LISTED
FOR OUTSIDE SERVICE AND AUDIBLE FROM THE ADDRESS THAT THE
HOUSE IS ADDRESSED ON.
SMOKE DETECTORS TO BE INSTALLED BY OTHERS.
RESIDENTIAL CONCEALED PENDENT SPRINKLERS ARE U.L. LISTED AND
MANUFACTURED BY VIKING. INSTALLED AT 16 FT. MAXIMUM SPACING
(SEE TECH. DATA).
PENDENT INTERMEDIATE TEMP. QUICK RESPONSE SPRINKLERS ARE U.L.
LISTED AND MANUFACTURED BY VIKING INSTALLED AT 16 FT. MAX. SPACING
(SEE TECH. DATA).
13.PENDENT SPRINKLERS ARE AT LEAST 3 ft. FROM OBSTRUCTIONS E.G. LIGHT
FIXTURES, CEILING FANS, ETC. OR IN ACCORDANCE WITH TABLE 8.2.5.4.2 AND
SECTION 8.2.5.1. SPRINKLER LOCATIONS FOR CONTINUOUS OBSTRUCTIONS
ARE IN COMPLIANCE WITH 8.2.5.4.
14.SOFFITS AND CABINETS TO BE PROVIDED WITH SPRINKLER COVERAGE IN
ACCORDANCE WITH 8.2.5.5.
UNDERGROUND DETAIL
N.T.S. (FOR REFERENCE ONLY)
RISER DETAIL
N.T.S.
HYDRAULIC NAMEPLATE
N.T.S.
VICINITY MAP
N.T.S.
LEGAL DESCRIPTION
HANGER TIC DETAIL
BUILDING SUMMARY
SYMBOL LEGEND
HYDRAULIC SYSTEM
This Building is Protected by a
Hydraulically Designed
Automatic Sprinkler System.
Date Installed
Location
Number of Sprinklers
Basis of Design
1. DENSITY
2. DESIGNED AREA OF DISCHARGE
System Demand
1. WATER FLOW RATE
2. RESIDUAL PRESSURE AT THE
BASE OF THE RISER
Installed By
Fire Sprinkler Systems, Inc.
8/18/22
CALC AREA 1
2
.05 gpm/sq.ft.
512 sq.ft.
31.3 gpm
34.7 psi
RESIDUAL
STATIC
78.6 - 10% = 70.7 PSI
83.2 - 10% = 74.9 PSI
WATER FLOW INFORMATION
FLOW 1,000 GPM
MAIN DRAIN VALVE
DRAIN TO EXTERIOR
RUBBER FACED CHECK VALVE
ELEV.
GAUGE
1/2"
CPVC TO SYSTEM
11'
CPVC RISER1"
10
ALL WORK FOR FIRE SPRINKLER
SYSTEMS, INC. TO BEGIN AT B.O.R.
1"
C
P
V
C
5
3 PSI LOSS
15.SPARE SPRINKLERS SHALL NOT BE REQUIRED TO BE PROVIDED IN
ACCORDANCE WITH 5.1.1.2
NOT BE REQUIRED TO
SPARE SPRINKLERS SHALL
PROVIDED PER 5.1.1.2
3
MASTER PLAN SUBMITTAL
POINT HAPPY
TRACT #31348
MA
S
T
E
R
P
L
A
N
S
U
B
M
I
T
T
A
L
P
O
I
N
T
H
A
P
P
Y
TR
A
C
T
#
3
1
3
4
8
14" x 14"
ELMDOR ED
ACCESS PANEL
EXTERIOR PANEL
NOTE:
INSTALLED BY OTHERS
SUPPLIED BY FSS;STATIC PRESSURE = 85.2 PSI
PSI LOSS - 2.0
83.2 PSI
PSI LOSS = 2.0
x .434
4.7'
HIGHEST F.F. ELEV. @ 79.7'
TEST HYDRANT ELEV. @ 75'
ELEV. DIFFERENCE =
RESIDUAL PRESSURE = 80.6 PSI
PSI LOSS - 2.0
78.6 PSI
6
7
ELEV.4'
PLAN 1
PL
A
N
1
3/
2
1
/
2
4
AS
B
U
I
L
T
:
R
E
V
I
S
E
W
A
T
E
R
M
E
T
E
R
T
O
3
/
4
"
(
A
D
)
1
S:\2022\32288\DWG\32288-DE.dwg, 3/21/2024 8:50:12 PM, DWG To PDF.pc3
The approval of plans and specications does not
permit the violation, deletion, omission or faulty
installation of any requirements of Title 24 or any
Local Ordinances. Construction shall remain
accessible and exposed for inspection purposes
until approved by the Fire Department.
Riverside County Fire Department
Oce of the Fire Marshal
APPROVAL
By:
Permit # :
Lucero Iñiguez, Fire Safety Specialist
04/09/2024
FRSS2024-0063
LICENSE NO. 684600
705 E. HARRISON ST., SUITE 200
CORONA, CA 92879
PH - 800-915-3473
FAX - 951-272-2535
CUSTOM, TRACT, MULTI-FAMILY
AND COMMERCIAL
DESIGN, C.P.INEERING AND
INSTALLATION
1/4" = 1'
IF SHEET IS LESS THAN
SIZE - 24" X 36"
SHEET ID
24" X 36" IT IS A REDUCED
SCALE
PRINT SCALE
REDUCE ACCORDINGLY
CLASSIFICATION
C-16
LICENSE NO.
684600
F
I
RE
PR O T E C T I ON CO
N
T
R
A
C
T
O
RF
S
T
A
TE
OF C A L I F O RN
IA
The recipient of these plans
hereby acknowledges that all
plans, details, specifications or
methods of installation
contained in this set of plans is
the sole property of Fire
Sprinkler Systems, Inc. and
that any use of this set of plans
is prohibited and is a violation
of copyright laws without first
receiving permission from Fire
Sprinkler Systems.
PLAN 1
FIRE SPRINKLER PLAN
SHEET FP2 OF FP3
DESIGN AND INSTALLATION SHALL
CONFORM TO NFPA 13D, 2016 ED.
NOTES:
1.ALL HEAD SPACING TO BE 16'x16', UNLESS OTHERWISE
NOTED.
2.ALL PIPES TO BE ¾" CPVC, UNLESS OTHERWISE NOTED.
3.PIPE CLEARANCES MUST BE IN ACCORDANCE WITH NFPA
13-9.3.4.
4.HANGERS SHOWN FOR REFERENCE PURPOSES ONLY.
HANGER SPACING TO BE PER TABLES ON THIS SHEET.
5.ALL PIPING INSTALLED WITHIN THE ATTIC SHALL BE
PROVIDED WITH MIN. 6" INSULATION ON THE ATTIC SIDE OF
THE PIPING TO AVOID EXPOSURE OF THE PIPING TO
TEMPERATURES IN EXCESS OF THE PIPES RATED
TEMPERATURE (2016 NFPA 13D 7.7).
6.SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF
55sqft. AND LESS. (SECTION 8.3.2.)
7.SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES
CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL
OF THE FOLLOWING REQUIREMENTS:
(1) THE AREA OF THE SPACE DOES NOT EXCEED 24sqft.
(2) THE WALLS AND CEILINGS ARE SURFACED WITH
NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE
MATERIALS AS DEFINED IN NFPA 220.
8. 8.2.5.1.2 THE DISTANCE SHALL BE MEASURED FROM THE
CENTER OF THE SPRINKLER TO THE CENTER OF THE
OBSTRUCTION.
9. 8.2.5.6 SHADOW AREAS SHALL BE PERMITTED IN THE
PROTECTION AREA OF A SPRINKLER AS LONG AS THE
CUMULATIVE DRY AREA DO NOT EXCEED 15sqft (1.4 sqm)
PER SPRINKLER.
TOTAL LIVING AREA -
GARAGE AREA-
2,752 SQFT.
773 SQFT.
NO
.
DA
T
E
RE
V
I
S
I
O
N
1 2 3 4 5
Size Range:3 4" through 3"
Finish: Pre-Galvanized Carbon Steel per ASTM A653
Service: Hanger for CPVC, steel, & copper pipe in the horizontal position on the bottom
and side of structural wood beams, composite beams and Steel 20 Ga. (min.) (Fig. A, C
respectively). Can be used as a restrainer when installed on top of structural wood beams
(Fig. B), for limiting pipe movement due to thrust loads during sprinkler system start-up.
It can also be used as a guide to limit movement for pipe in the vertical position. When
used on composite wood beams, web thickness must be 3 8" or greater.
Approvals: cULus Listed
Installation:
• Snap hanger over pipe.
• Secure hanger to mounting surface with screws provided.
• Do not make adjustments to hanger mounting flanges that result in clamping the pipe to the mounting surface. Pipe must be
allowed to move freely through hanger.
• Steel applications require two (2) #14 x 1" hex washer head self-drilling TEK screws. Not Supplied. Part Number STD-0090.
Features:
• Beveled edge design helps protect the CPVC pipe from any rough surface.
• Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product.
• Retaining dimples hold the strap onto the pipe for ease of installation. (Not shown)
Ordering: Specify pipe size, figure number, and description.
Fig. A Fig. B
Pipe Size
1
2
3
A
1
11⁄4
B
Fig. C
FIG. 186: DIMENSIONS (IN) • WEIGHT (LBS)
øC E
1⁄4
F Approx.
Weight/100 (lbs)
5
6
7
8
9
14
17
3 4
11 4
112
212
15 16
19 16
113 16
21 4
25 8
213 16
31 4
33 8
37 8
45 16
53 8
65 16
11 8
13 16
118
1½
11116
218
29 16
27 8
312
No pre-drilling required.
NOT TO SCALE
ANVIL 186 HANGER (STEEL - COPPER - C.P.V.C.)
Size Range:3 4" through 2"
Material: Carbon Steel
Finish: Pre-Galvanized per ASTM A653
Service:
• Hanger and surge restraint for horizontal CPVC, steel, and copper piping when installed
on the top, bottom, and side of the supporting structure.
• Guide for vertical CPVC, steel, and copper piping when installed on the side of the
supporting structure.
• Horizontal and vertical seismic restraint per NFPA 13-2016 requirements.
• May be installed with concrete, steel structural members, and other structural
members with fasteners which comply with the requirements of NFPA 13.
Approvals: cULus Listed
Patents: No. 6,648,278
Installation:
• Snap hanger over pipe. If needed, squeeze strap back around pipe.
• CPVC pipe must be allowed to slide freely through the Fig. 188R.
• Secure hanger to mounting surface with screws provided or with listed fasteners.
Features:
• Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion.
• Easily attaches to wood structure with #10 x 1" hex washer head self-threading screw supplied with
product. No pre-drilling required.
• Bottom of pipe is offset 112" from the structure. Eliminates wooden spacer blocks.
Ordering: Specify CPVC pipe size, figure number and description.
Hanger &
Restrainer
Installation - Backing Nut
Hanger = 1 - at top fastener
Restraint = 2 - on each fastener
Hanger &
Restrainer
Guide &
Restrainer Per NFPA-13D and NFPA-13R
B
A
E øC
F
D
G
Hanger and Restrainer
FIG. 188R: DIMENSIONS (IN) • WEIGHT (LBS)
CPVC
Pipe Size
3 4
1
114
112
2
A
23 4
35 8
B
312
312
314
414
43 8
øC
¼
¼
¼
¼
¼
D
2
E
1
1
1
1
1
F
25 8
314
312
4
FIG. 188R: LISTED FASTENERS
Pipe
CPVC
Steel & Copper
Wood and Composite Beams
Screw Supplied or #10 x 1" TEK Screw
#14 x 1" TEK Screw or 14"x112" Lag Screw
Steel (18ga. Minimum)
#14 x 1" TEK Screw or 14"x1" TEK Screw
#14 x 1" TEK Screw or 14"x1" TEK Screw
G
112
Max. Hanger
Spacing (FT.)
512
6
612
7
8
Approx.
Weight/100 (lbs)
11
12
13
14
16
21316
21316
31116
23 16
2516
2716
21116
35 8 112
112
112
112
NOT TO SCALE
ANVIL 188R HANGER (STEEL - COPPER - C.P.V.C.)
SP
A
C
I
N
G
TE
M
P
.
K-
F
A
C
.
SY
M
B
O
L
MO
D
E
L
MA
N
U
F
.
SI
N
#
OR
I
F
I
C
E
14 7
QU
A
N
T
I
T
Y
-
TO
T
A
L
S
P
R
I
N
K
L
E
R
S
I
N
T
H
I
S
S
H
E
E
T
:
276
-
-
-
-
-
-
-
VI
K
I
N
G
VI
K
I
N
G
4.
9
4.
9
20
0
°
17
5
°
16
'
x
1
6
'
16
'
x
1
6
'
VK
4
9
4
VK
4
6
8
FR
E
E
D
O
M
PE
N
D
E
N
T
7/
1
6
"
7/
1
6
"
FR
E
E
D
O
M
CO
N
C
.
P
E
N
D
.
-
J
J
J
SA
SA/COD
SA
J
J
J
SA/COD
SA
J J
SCALE: 1/4" = 1'-0"
PLAN 1 - FIRE SPRINKLER PLAN
HEAT ZONE
ATTIC
ACCESS
DINING ROOM
10'-0" CLG.OUTDOOR ROOM
10'-0" CLG.
PRIMARY BEDROOM
10'-0" CLG.
KITCHEN
10'-0" CLG.
GREAT ROOM
SLOPED CLG.
FOYER
10'-0" CLG.
9 SQFT.
LAUNDRY
10'-0" CLG.
PANTRY
10'-0" CLG.
GARAGE
10'-0" CLG.
COVERED ENTRY
10'-0" CLG.
BATH 3
10'-0" CLG.
13 SQFT.
BEDROOM 3
10'-0" CLG.
13 SQFT.
BATH 2
10'-0" CLG.
BEDROOM 2
10'-0" CLG.
FLEX ROOM
10'-0" CLG.
W.I.C.
10'-0" CLG.
24 SQFT.
PRIMARY BATH
10'-0" CLG.
4:12
SLOPE
4:12
SLOPE
DROP ZONE
10'-0" CLG.
1-CAR GARAGE
10'-0" CLG.
52 SQFT.
POWDER
10'-0" CLG.
33 SQFT.
DRAWN BY:
32288
8/18/22
JOB NO:
DATE:
C.P.
RISER
LOCATION
10
20'x20' SPACING
CALC AREA 2
10'-1"7'-10"
3'
-
6
"
12
'
-
5
"
9'
-
1
0
"
2'
-
2
"
3'
-
1
1
"
15
'
-
8
"
1'
12
'
8'12'-8"9'-8"3'-5"2'-10"3'-9"
14
'
-
9
"
12
'
-
6
"
9'
-
7
"
11
'
-
7
"
7'
-
1
0
"
1'8'1'-9"
8'
-
1
0
"
10
'
-
1
1
"
5'
-
2
"
9'-7"10'-11"1'-7"
3'
-
6
"
12
'
-
5
"
3'
-
8
"
5'
3'
-
1
0
"
5'
-
1
0
"
3'
-
7
"
6'
-
5
"
2'
-
6
"
6'
-
3
"
3'-1"
3'-1"
1'-3"
4'-8"
6'
-
6
"
3'
1'-9"
2'-2"
2'-9"
2'-11"
1'
-
4
"
6"
5'-2"2'-10"
2'-4"5'-8"
8'
4'-7"
12
'
-
5
"
13'-3"
6'-4"
5'
-
5
"
4'
-
4
"
4'-7"
5'
-
1
0
"
4'-8"
7'-6"
8
'
-
1
1
"
9'8'
8'
6'
-
2
"
8'-7"
6'
-
2
"
8'-5"
8'-1"
6'
-
1
"
8'
-
9
"
9'-3"
10'
9'
-
5
"
4'
-
3
"
3'-1"
10
'
10'
3'
-
7
"
13
'
15
'
-
8
"
7'-7"
8'
4'
-
1
0
"
9'
-
6
"
8'
7'
7'
-
8
"
7'
(2)
9
0
°
E
L
B
O
W
S
(2)
9
0
°
E
L
B
O
W
S
20'x20' SPACING
20'x20' SPACING
20'x20' SPACING
20'x20' SPACING
20'x20' SPACING
16
17
18
12
151314
11
CALC AREA 1
57 SQ. FT.
2'
-
4
"
5'-9"
5'
6"
WI
L
L
I
A
M
S
H
O
M
E
S
BY
:
LA
Q
U
I
N
T
A
,
C
A
.
MA
S
T
E
R
P
L
A
N
S
U
B
M
I
T
T
A
L
P
O
I
N
T
H
A
P
P
Y
TR
A
C
T
#
3
1
3
4
8
PL
A
N
1
VI
K
I
N
G
4.
9
20
0
°
20
'
x
2
0
'
VK
4
9
4
7/
1
6
"
FR
E
E
D
O
M
CO
N
C
.
P
E
N
D
.
3/
2
1
/
2
4
AS
B
U
I
L
T
:
R
E
V
I
S
E
W
A
T
E
R
M
E
T
E
R
T
O
3
/
4
"
(
A
D
)
S:\2022\32288\DWG\32288-DE.dwg, 3/21/2024 8:50:27 PM, DWG To PDF.pc3
LICENSE NO. 684600
705 E. HARRISON ST., SUITE 200
CORONA, CA 92879
PH - 800-915-3473
FAX - 951-272-2535
CUSTOM, TRACT, MULTI-FAMILY
AND COMMERCIAL
DESIGN, C.P.INEERING AND
INSTALLATION
1/4" = 1'
IF SHEET IS LESS THAN
SIZE - 24" X 36"
SHEET ID
24" X 36" IT IS A REDUCED
SCALE
PRINT SCALE
REDUCE ACCORDINGLY
CLASSIFICATION
C-16
LICENSE NO.
684600
F
I
RE
PR O T E C T I ON CO
N
T
R
A
C
T
O
RF
S
T
A
TE
OF C A L I F O RN
IA
The recipient of these plans
hereby acknowledges that all
plans, details, specifications or
methods of installation
contained in this set of plans is
the sole property of Fire
Sprinkler Systems, Inc. and
that any use of this set of plans
is prohibited and is a violation
of copyright laws without first
receiving permission from Fire
Sprinkler Systems.
SE
C
T
I
O
N
S
F
O
R
R
E
F
E
R
E
N
C
E
O
N
L
Y
PLAN 1
SECTIONS
SHEET FP3 OF FP3
NO
.
DA
T
E
RE
V
I
S
I
O
N
1 2 3 4 5
DRAWN BY:
32288
8/18/22
JOB NO:
DATE:
C.P.
ATTIC
ACCESS
BATH 3
10'-0" CLG.
13 SQFT.
BEDROOM 2
10'-0" CLG.
EXERCISE ROOM
10'-0" CLG.
W.I.C.
10'-0" CLG.
24 SQFT.
POWDER
10'-0" CLG.
33 SQFT.
12
'
-
6
"
9'
-
7
"
4'
-
9
"
5'
-
2
"
10'-11"1'-7"
3'
1'-9"
2'-11"
1'
-
4
"
7'-6"
8
'
-
1
1
"
8'-1"
6'
-
1
"
8'
-
9
"
20'x20' SPACING
20'x20' SPACING
57 SQ. FT.
2'
-
4
"
5'-9"
5'
+1 HEAD / IN LIEU OF: FLEX
OPT. EXERCISE ROOM
3'-9"
1'
-
6
"
13
'
-
2
"
8'
13
'
-
2
"
6'-3"
PRIMARY BATH
10'-0" CLG.
43 SQFT.
SCALE: 1/4" = 1'-0"
2 SQFT.
WI
L
L
I
A
M
S
H
O
M
E
S
BY
:
LA
Q
U
I
N
T
A
,
C
A
.
MA
S
T
E
R
P
L
A
N
S
U
B
M
I
T
T
A
L
P
O
I
N
T
H
A
P
P
Y
TR
A
C
T
#
3
1
3
4
8
PL
A
N
1
3/
2
1
/
2
4
AS
B
U
I
L
T
:
R
E
V
I
S
E
W
A
T
E
R
M
E
T
E
R
T
O
3
/
4
"
(
A
D
)
S:\2022\32288\DWG\32288-DE.dwg, 3/21/2024 8:50:40 PM, DWG To PDF.pc3