PGA West - Residence Club TR 31627 BCRP2018-0007 - Energy CalculationsCERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 1 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
GENERAL INFORMATION
01 Project Name Residence Club
02 Calculation Description Title 24 Analysis
03 Project Location @ PGA West
04 City La Quinta 05 Standards Version Compliance 2017
06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149)
08 Climate Zone CZ15 09 Software Version EnergyPro 7.2
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)3567 15 Number of Zones 3
16 Slab Area (ft2)3567 17 Number of Stories 1
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)14.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CITY OF LA QUINTA
BUILDING DIVISION
BY: DATE:
REVIEWED FOR
CODE COMPLIANCE
10/04/2019
BCPR2018-0007
SFD X 1 WITH TWO ELEVATIONS
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 2 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
ENERGY USE SUMMARY
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating 2.90 4.56 -1.66 -57.2%
Space Cooling 82.83 66.34 16.49 19.9%
IAQ Ventilation 0.85 0.85 0.00 0.0%
Water Heating 3.64 7.89 -4.25 -116.8%
PV Credit ---- 0.00 0.00 ----
North Facing Compliance Total 90.22 79.64 10.58 11.7%
Space Heating 2.90 4.37 -1.47 -50.7%
Space Cooling 82.83 73.42 9.41 11.4%
IAQ Ventilation 0.85 0.85 0.00 0.0%
Water Heating 3.64 7.89 -4.25 -116.8%
PV Credit ---- 0.00 0.00 ----
East Facing Compliance Total 90.22 86.53 3.69 4.1%
Space Heating 2.90 5.03 -2.13 -73.4%
Space Cooling 82.83 67.88 14.95 18.0%
IAQ Ventilation 0.85 0.85 0.00 0.0%
Water Heating 3.64 7.89 -4.25 -116.8%
PV Credit ----0.00 0.00 ----
South Facing Compliance Total 90.22 81.65 8.57 9.5%
Space Heating 2.90 4.97 -2.07 -71.4%
Space Cooling 82.83 67.45 15.38 18.6%
IAQ Ventilation 0.85 0.85 0.00 0.0%
Water Heating 3.64 7.89 -4.25 -116.8%
PV Credit ----0.00 0.00 ----
West Facing Compliance Total 90.22 81.16 9.06 10.0%
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 3 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
North 49.2 44.6 0.0 44.6
East 49.2 47.6 0.0 47.6
South 49.2 45.5 0.0 45.5
West 49.2 45.3 0.0 45.3
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
•Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•IAQ mechanical ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
•Duct Sealing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 4 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Residence Club 3567 1 3 3 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Bedroom 2 residence club Conditioned HVAC bed 21 820 11.8 DHW Sys 1 n/a
living area residence clu Conditioned HVAC great2 1483 11.8 DHW Sys 1 n/a
bedroom 1 residence club Conditioned HVACbed13 1264 11.8 DHW Sys 1 n/a
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 5 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
NE Wall Bedroom 2 residence club R-21 Wall 180 Back 250 72 90
SE Wall Bedroom 2 residence club R-21 Wall 270 Right 500 0 90
SW Wall Bedroom 2 residence club R-21 Wall 0 Front 250 0 90
NW Wall Bedroom 2 residence club R-21 Wall 90 Left 250 0 90
Interior Surface Bedroom 2 residence club>>living
area residence clu R-0 Interior Surface n/a n/a 388 0 n/a
Roof Bedroom 2 residence club R-38 Roof Attic W/ R-19 n/a n/a 820 n/a n/a
NE Wall 2 living area residence clu R-21 Wall 180 Back 560 300 90
SE Wall 2 living area residence clu R-21 Wall 270 Right 120 0 90
SW Wall 2 living area residence clu R-21 Wall 0 Front 560 24 90
NW Wall 2 living area residence clu R-21 Wall 90 Left 120 58 90
Interior Surface 2 living area residence clu>>bedroom 1
residence club R-0 Interior Surface n/a n/a 482 0 n/a
Roof 2 living area residence clu R-38 Roof Attic W/ R-19 n/a n/a 1483 n/a n/a
NE Wall 3 bedroom 1 residence club R-21 Wall 180 Back 390 41.4 90
SE Wall 3 bedroom 1 residence club R-21 Wall 270 Right 260 48 90
SW Wall 3 bedroom 1 residence club R-21 Wall 0 Front 390 32 90
NW Wall 3 bedroom 1 residence club R-21 Wall 90 Left 936 40 90
Interior Surface 3 bedroom 1 residence club>>Bedroom
2 residence club R-0 Interior Surface n/a n/a 382 0 n/a
Roof 3 bedroom 1 residence club R-38 Roof Attic W/ R-19 n/a n/a 1264 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Bedroom 2 residence
club
Attic RoofBedroom 2
residence club Unventilated 3 0.1 0.85 Yes No
Attic living area residence clu Attic Roofliving area
residence clu Unventilated 3 0.1 0.85 Yes No
Attic bedroom 1 residence
club
Attic Roofbedroom 1
residence club Unventilated 3 0.1 0.85 Yes No
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 6 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
104 Window NE Wall (Back-180)--------1 72.0 0.57 0.20 Insect Screen (default)
105 Window NE Wall 2 (Back-180)30.0 10.0 1 300.0 0.47 0.22 Insect Screen (default)
C Window NW Wall 2 (Left-90)--------1 5.0 0.28 0.22 Insect Screen (default)
B Window NW Wall 2 (Left-90)--------1 5.0 0.28 0.22 Insect Screen (default)
G or E Window NE Wall 3 (Back-180)--------1 13.8 0.27 0.22 Insect Screen (default)
H or F Window NE Wall 3 (Back-180)--------1 13.8 0.27 0.22 Insect Screen (default)
I or G Window NE Wall 3 (Back-180)--------1 13.8 0.27 0.22 Insect Screen (default)
106 Window SE Wall 3 (Right-270)--------1 24.0 0.47 0.22 Insect Screen (default)
A Window SW Wall 3 (Front-0)--------1 32.0 0.26 0.22 Insect Screen (default)
M or K Window NW Wall 3 (Left-90)--------1 15.0 0.28 0.20 Insect Screen (default)
J or H Window NW Wall 3 (Left-90)--------1 5.0 0.28 0.20 Insect Screen (default)
K or I Window NW Wall 3 (Left-90)--------1 15.0 0.28 0.20 Insect Screen (default)
L or J Window NW Wall 3 (Left-90)--------1 5.0 0.28 0.20 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door SW Wall 2 24.0 0.50
Door 101 NW Wall 2 24.0 0.50
Door 119 NW Wall 2 24.0 0.50
Door 107 SE Wall 3 24.0 0.50
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
105 18 0.1 18 18 0 0 0 0 0 0 0 0 0
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 7 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
Attic RoofBedroom 2 residence
club Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 19 0.059
•Around Roof Joists: R-6.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Roofing: Light Roof (Asphalt Shingle)
R-38 Roof Attic W/ R-19
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 16 in. O.C.R 38 0.025
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-28.9 insul.
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.069
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Exterior Finish: 3 Coat Stucco
R-0 Interior Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.277
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Other Side Finish: Gypsum Board
Attic Roofliving area residence
clu Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 19 0.059
•Around Roof Joists: R-6.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Roofing: Light Roof (Asphalt Shingle)
Attic Roofbedroom 1 residence
club Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.R 19 0.059
•Around Roof Joists: R-6.0 insul.
•Cavity / Frame: R-13.0 / 2x4 Top Chrd
•Roof Deck: Wood Siding/sheathing/decking
•Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab-on-Grade Bedroom 2 residence club 820 90 None 0.8 No
Slab-on-Grade 2 living area residence clu 1483 102 None 0.8 No
Slab-on-Grade 3 bedroom 1 residence club 1264 132 None 0.8 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 8 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0%
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1 Gas Large Storage 1 75 0.8 TE 75,100 Btu/hr R-0/R-0 0.0253 n/a n/a n/a
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC bed 21 Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
HVAC great2 Other Heating and Cooling
System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2
HVACbed13 Other Heating and Cooling
System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 1 80 AFUE
Heating Component 2 CntrlFurnace 1 80 AFUE
Heating Component 3 CntrlFurnace 1 80 AFUE
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 9 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Efficiency
Zonally Controlled Compressor Type
Name System Type Number of Units EER SEER HERS Verification
Cooling Component 1 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component
1-hers-cool
Cooling Component 2 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component
2-hers-cool
Cooling Component 3 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component
3-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool Required 350 Required Required Required
Cooling Component 2-hers-cool Required 350 Required Required Required
Cooling Component 3-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctsAttic Specified Lower Leakage
Target 8 Attic None Air Distribution System
1-hers-dist
Air Distribution System 2 DuctsAttic Specified Lower Leakage
Target 8 Attic None Air Distribution System
2-hers-dist
Air Distribution System 3 DuctsAttic Specified Lower Leakage
Target 8 Attic None Air Distribution System
3-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 10 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.54 HVAC Fan 1-hers-fan
HVAC Fan 2 Single Speed PSC Furnace Fan 0.54 HVAC Fan 2-hers-fan
HVAC Fan 3 Single Speed PSC Furnace Fan 0.54 HVAC Fan 3-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.54
HVAC Fan 2-hers-fan Required 0.54
HVAC Fan 3-hers-fan Required 0.54
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam IAQVentRpt 66 0.25 Default 0 Required
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 11 of 11
Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Tim Scott
Scott Design and Title 24, Inc.
77085 Michigan Drive
Palm Desert, CA 92211
2019-09-23 08:55:32
760-200-4780
Tim Scott
Scott Design and Title 24, Inc.
77085 Michigan Drive
Palm Desert, CA 92211
2019-09-23 08:55:32
na
760-200-4780
Tim Scott
Tim Scott
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.