Loading...
PGA West - Residence Club TR 31627 BCRP2018-0007 - Energy CalculationsCERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 1 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    GENERAL INFORMATION 01 Project Name Residence Club 02 Calculation Description Title 24 Analysis 03 Project Location @ PGA West   04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal)Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2)3567 15 Number of Zones 3 16 Slab Area (ft2)3567 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)14.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CITY OF LA QUINTA BUILDING DIVISION BY: DATE: REVIEWED FOR CODE COMPLIANCE 10/04/2019 BCPR2018-0007 SFD X 1 WITH TWO ELEVATIONS CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 2 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    ENERGY USE SUMMARY Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.90  4.56  -1.66 -57.2% Space Cooling 82.83  66.34  16.49 19.9% IAQ Ventilation 0.85  0.85  0.00 0.0% Water Heating 3.64  7.89  -4.25 -116.8% PV Credit ---- 0.00 0.00 ---- North Facing Compliance Total 90.22  79.64 10.58 11.7% Space Heating 2.90  4.37  -1.47 -50.7% Space Cooling 82.83  73.42  9.41 11.4% IAQ Ventilation 0.85  0.85  0.00 0.0% Water Heating 3.64  7.89  -4.25 -116.8% PV Credit ---- 0.00 0.00 ---- East Facing Compliance Total 90.22 86.53 3.69 4.1% Space Heating 2.90 5.03 -2.13 -73.4% Space Cooling 82.83 67.88 14.95 18.0% IAQ Ventilation 0.85  0.85 0.00 0.0% Water Heating 3.64 7.89 -4.25 -116.8% PV Credit ----0.00 0.00 ----  South Facing Compliance Total 90.22 81.65 8.57 9.5% Space Heating 2.90 4.97 -2.07 -71.4% Space Cooling 82.83 67.45 15.38 18.6% IAQ Ventilation 0.85 0.85 0.00 0.0% Water Heating 3.64 7.89 -4.25 -116.8% PV Credit ----0.00 0.00 ---- West Facing Compliance Total 90.22 81.16 9.06 10.0% 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 3 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen  EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR North 49.2 44.6 0.0 44.6 East 49.2 47.6 0.0 47.6 South 49.2 45.5 0.0 45.5 West 49.2 45.3 0.0 45.3 Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: •Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.  •Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis.  Additional detail is provided in the building components tables below. Building-level Verifications: •High quality insulation installation (QII) •IAQ mechanical ventilation Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM HVAC Distribution System Verifications: •Duct Sealing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 4 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation  Cooling Systems Number of Water Heating  Systems Residence Club 3567 1 3 3 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Bedroom 2 residence club Conditioned HVAC bed 21 820 11.8 DHW Sys 1 n/a living area residence clu Conditioned HVAC great2 1483 11.8 DHW Sys 1 n/a bedroom 1 residence club Conditioned HVACbed13 1264 11.8 DHW Sys 1 n/a 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 5 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg) NE Wall Bedroom 2 residence club R-21 Wall 180 Back 250 72 90 SE Wall Bedroom 2 residence club R-21 Wall 270 Right 500 0 90 SW Wall Bedroom 2 residence club R-21 Wall 0 Front 250 0 90 NW Wall Bedroom 2 residence club R-21 Wall 90 Left 250 0 90 Interior Surface Bedroom 2 residence club>>living area residence clu R-0 Interior Surface n/a n/a 388 0 n/a Roof Bedroom 2 residence club R-38 Roof Attic W/ R-19 n/a n/a 820 n/a n/a NE Wall 2 living area residence clu R-21 Wall 180 Back 560 300 90 SE Wall 2 living area residence clu R-21 Wall 270 Right 120 0 90 SW Wall 2 living area residence clu R-21 Wall 0 Front 560 24 90 NW Wall 2 living area residence clu R-21 Wall 90 Left 120 58 90 Interior Surface 2 living area residence clu>>bedroom 1 residence club R-0 Interior Surface n/a n/a 482 0 n/a Roof 2 living area residence clu R-38 Roof Attic W/ R-19 n/a n/a 1483 n/a n/a NE Wall 3 bedroom 1 residence club R-21 Wall 180 Back 390 41.4 90 SE Wall 3 bedroom 1 residence club R-21 Wall 270 Right 260 48 90 SW Wall 3 bedroom 1 residence club R-21 Wall 0 Front 390 32 90 NW Wall 3 bedroom 1 residence club R-21 Wall 90 Left 936 40 90 Interior Surface 3 bedroom 1 residence club>>Bedroom 2 residence club R-0 Interior Surface n/a n/a 382 0 n/a Roof 3 bedroom 1 residence club R-38 Roof Attic W/ R-19 n/a n/a 1264 n/a n/a     ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Bedroom 2 residence club Attic RoofBedroom 2 residence club Unventilated 3 0.1 0.85 Yes No Attic living area residence clu Attic Roofliving area residence clu Unventilated 3 0.1 0.85 Yes No Attic bedroom 1 residence club Attic Roofbedroom 1 residence club Unventilated 3 0.1 0.85 Yes No   218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 6 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation-Azimuth)Width (ft) Height (ft)Multiplier Area (ft2)U-factor SHGC Exterior Shading 104 Window NE Wall (Back-180)--------1 72.0 0.57 0.20 Insect Screen (default) 105 Window NE Wall 2 (Back-180)30.0 10.0 1 300.0 0.47 0.22 Insect Screen (default) C Window NW Wall 2 (Left-90)--------1 5.0 0.28 0.22 Insect Screen (default) B Window NW Wall 2 (Left-90)--------1 5.0 0.28 0.22 Insect Screen (default) G or E Window NE Wall 3 (Back-180)--------1 13.8 0.27 0.22 Insect Screen (default) H or F Window NE Wall 3 (Back-180)--------1 13.8 0.27 0.22 Insect Screen (default) I or G Window NE Wall 3 (Back-180)--------1 13.8 0.27 0.22 Insect Screen (default) 106 Window SE Wall 3 (Right-270)--------1 24.0 0.47 0.22 Insect Screen (default) A Window SW Wall 3 (Front-0)--------1 32.0 0.26 0.22 Insect Screen (default) M or K Window NW Wall 3 (Left-90)--------1 15.0 0.28 0.20 Insect Screen (default) J or H Window NW Wall 3 (Left-90)--------1 5.0 0.28 0.20 Insect Screen (default) K or I Window NW Wall 3 (Left-90)--------1 15.0 0.28 0.20 Insect Screen (default) L or J Window NW Wall 3 (Left-90)--------1 5.0 0.28 0.20 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door SW Wall 2 24.0 0.50 Door 101 NW Wall 2 24.0 0.50 Door 119 NW Wall 2 24.0 0.50 Door 107 SE Wall 3 24.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14  Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 105 18 0.1 18 18 0 0 0 0 0 0 0  0 0 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 7 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Attic RoofBedroom 2 residence club Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C.R 19 0.059 •Around Roof Joists: R-6.0 insul. •Cavity / Frame: R-13.0 / 2x4 Top Chrd •Roof Deck: Wood Siding/sheathing/decking •Roofing: Light Roof (Asphalt Shingle) R-38 Roof Attic W/ R-19 Ceilings (below attic)Wood Framed Ceiling 2x4 @ 16 in. O.C.R 38 0.025 •Inside Finish: Gypsum Board •Cavity / Frame: R-9.1 / 2x4 •Over Ceiling Joists: R-28.9 insul. R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.069 •Inside Finish: Gypsum Board •Cavity / Frame: R-21 / 2x6 •Exterior Finish: 3 Coat Stucco R-0 Interior Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.277 •Inside Finish: Gypsum Board •Cavity / Frame: no insul. / 2x4 •Other Side Finish: Gypsum Board Attic Roofliving area residence clu Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C.R 19 0.059 •Around Roof Joists: R-6.0 insul. •Cavity / Frame: R-13.0 / 2x4 Top Chrd •Roof Deck: Wood Siding/sheathing/decking •Roofing: Light Roof (Asphalt Shingle) Attic Roofbedroom 1 residence club Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C.R 19 0.059 •Around Roof Joists: R-6.0 insul. •Cavity / Frame: R-13.0 / 2x4 Top Chrd •Roof Deck: Wood Siding/sheathing/decking •Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated Slab-on-Grade Bedroom 2 residence club 820 90 None 0.8 No Slab-on-Grade 2 living area residence clu 1483 102 None 0.8 No Slab-on-Grade 3 bedroom 1 residence club 1264 132 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 8 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1)1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Large Storage 1 75 0.8 TE 75,100 Btu/hr R-0/R-0 0.0253 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC bed 21 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC great2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVACbed13 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 1 80 AFUE 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 9 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08    Efficiency Zonally Controlled Compressor Type   Name System Type Number of Units EER SEER HERS Verification Cooling Component 1 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 3-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required HVAC -  DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 2-hers-dist Air Distribution System 3 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 3-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08  Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage Name  Verification Target (%)Location Design Ducts Ducts Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 10 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    HVAC - FAN  SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.54 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.54 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.54 HVAC Fan 3-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.54 HVAC Fan 2-hers-fan Required 0.54 HVAC Fan 3-hers-fan Required 0.54 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%)HERS Verification SFam IAQVentRpt 66 0.25 Default 0 Required   218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:Residence Club Calculation Date/Time:08:47, Mon, Sep 23, 2019 Page 11 of 11 Calculation Description:Title 24 Analysis Input File Name:Residence Club-Jacobs-SCA-18.ribd16x Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-09-23 08:48:18    DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: Easy to Verify at CalCERTS.com Tim Scott Scott Design and Title 24, Inc. 77085 Michigan Drive Palm Desert, CA 92211 2019-09-23 08:55:32 760-200-4780 Tim Scott Scott Design and Title 24, Inc. 77085 Michigan Drive Palm Desert, CA 92211 2019-09-23 08:55:32 na 760-200-4780 Tim Scott Tim Scott Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 218-P010144276J-000-000-0000000-0000 2019-09-23 08:55:32 CalCERTS inc.