Loading...
BWFE2024-0279 Plans1 2 3 4 5 6 7 333435363738 25 40 41 42 43 44 45 46 47 72 71 70 69 68 67 66 LOT K LOT G LOT J 10 11 12 13 1415161718192021222324 26 27 28 29 30 31 32 39 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 SHEET 3 BR A D S H A W T R A I L SHEET 4 SHEET 5 SHEET 2 HERITAGE WAY CLARKE COURT H A P P Y PO I N T W A Y SHEET 6 LEGEND LOT NUMBER TRACT BOUNDARY PHASE BOUNDARY SLOPE RETAINING WALL SANITARY SEWER POTABLE WATER STORM DRAIN APPLICANT/OWNER WH LA QUINTA 29 LLC 24911 AVENUE STANFORD SANTA CLARITA, CA 91355 CONTACT: ZACH NORDLY EMAIL: ZNORDLY@WILLIAMSHOMES.COM TELEPHONE: (661) 877-6783 PREPARER ANDERSON CONSULTING ENGINEERS, INC 12526 HIGH BLUFF DRIVE, SUITE 300 SAN DIEGO, CA 92130 CONTACT: JEFFERY A. ANDERSON EMAIL: JEFF@ACE-CIVIL.COM TELEPHONE: (858) 524-6579 AMENDED TRACT NO. 31348 ESTATES AT POINT HAPPY WALL AND FENCE PLAN IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA 400'100' 200'200'600' 200 Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig ANDERSON CONSULTING ENGINEERS, INC. EXP. 09/30/24 NO. C 48750 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 SEPTEMBER 2022 NOT TO SCALE VICINITY MAP 390 SHEET INDEX MAP SCALE: 1" = 200' TITLE SHEET SHEET INDEX DESCRIPTION SHEET NO. TITLE SHEET...............................................................1 WALL AND FENCE PLAN LOTS 1-7 & 33-38..............2 WALL AND FENCE PLAN LOT 25 & SECTIONS..........3 WALL AND FENCE PLAN LOTS 40-47.......................4 WALL AND FENCE PLAN LOTS 66-72.......................5 WALL AND FENCE LOT 73 (BASIN) ..........................6 STRUCTURAL DETAILS & SPECIFICATIONS................ 7-8PROJECT LOCATION CONSTRUCTION NOTES CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-0" (PER DETAIL 3 ON SHEET 7). 1 2 OMIT HALF BLOCK AT GRADE TO ALLOW FOR DRAINAGE PER DETAIL (SEE SHT. 3). 3 CONSTRUCT COMBINATION BLOCK/VIEW FENCE (PER DETAIL 1 ON SHEET 7). 4 5 CONSTRUCT COMBINATION RETAINING/PRIVACY WALL, 8' MAX. (PER DETAIL 2 ON SHEET 7) LOTS 1 TO 7, 25, 33 TO 38, 40 TO 47, AND 66 TO 72 6 CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-8" (PER DETAIL 3 ON SHEET 7). CONSTRUCT RETAINING WALL, MAX. HEIGHT=6'-0" (PER DETAILS ON SHEET 8). 11-15-22 10/30/2024Edward Ghera BWFE2024-0279 WILLIAMS HOMES / 130 LF OF 6 FOOT HIGH GARDEN WALLS AT WEST P/L WITH RETURNS AND 2 PILASTERS AT ENTRY [PROTO II SPECIFICATIONS]. PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2022 CALIFORNIA BUILDING CODES. HERITAGE WAY 76.17 FF 75.5 PE 74.2FL 74.0FL 73.8 FL 73.4 FL 73.4 FL 72.8 FL 74.0FL 73.6 FL 73.2FL 73.1FL 74.2 FL 74.3 FL 73.9 FL 74.1 FL 73.7 FL 73.3 FL 74.8FL 74.5 FL 73.7 FL 73.5 FL 74.0FL 73.9 FL 73.1FL (74.06) TC(74.98) TC (73.69) TC (73.35) TC (73.00) TC (72.65) TC (72.32) TC (72.06) TC (73.91) TC 75.67 FF 75.0 PE 75.47 FF 74.8 PE 75.27FF 74.6 PE 75.07 FF 74.4 PE 74.87 FF 74.2 PE 74.67 FF 74.0 PE 75.77 FF 75.10 PE 75.47 FF 74.8 PE 75.27 FF 74.6 PE 75.07 FF 74.4 PE 74.87 FF 74.2 PE 74.67 FF 74.0 PE (75.74) (74.98) TC (74.98) 0.50% 0.50%1.46% (74.51) TC 1 2 3 4 5 6 7 33 34 353637 38 39 (74.25) TC(75.15) TC (73.82) TC (73.45) TC (73.08) TC (72.71) TC (72.34) TC (72.02) TC (71.87) TC (72.26) TC 0 . 5 % (72.34) TC (72.83) TC (75.9 PE) (77.5 PE) 0. 5 % 12 4 . 0 9 ' L=54.75 L=17.09 L=71.83 L=71.55 L =71.5 4 L =7 1 .7 9 L =6 4 .7 3 L =33.36 98 . 8 3 ' 87.94'71.50'71.50'71.50'71.50'71.50' 13 7 . 1 5 ' 13 9 . 5 6 ' 13 7 . 6 4 ' 13 1 . 3 7 ' 13 6 . 2 1 ' 12 9 . 1 5 ' 12 4 . 5 1 ' 12 2 . 9 6 ' 12 5 . 2 7 ' 13 1 . 4 5 ' L =5 1 .7 2 L =6 8 .7 9 L =6 8.5 5L=68.53L=68.72 L=43.19 L=25.81L=6 6.76 L=60.25 L = 9 2 . 7 9 L = 8 . 0 7 62.78'68.51'47.55'20.95'68.50'68.50'68.50'108.82' 4 1 . 0 9 ' L = 8 3 . 0 5 2 7 . 8 5 ' 13 0 . 3 8 ' R/W PUE EX. SWR EX. WTR EX. SD EX. SD B R A D S H A W T R A I L P O I N T H A P P Y W A Y 3 6 3 6 6 3 3 3 3 3 3 3 3 6 6 6 75.1 FG 75.1 FG 74.8 FG 74.8 FG 74.6 FG 74.6 FG 74.2 FG 74.2 FG 74.0 FG 74.0 74.4 FG 74.4 FG 79.8 TW 72.5 TF 79.8 TW 73.1 TF 74.0 FG74.2 FG 74.0 FG 80.0 TW 72.4 TF 79.7 TW 73.1 TF 74.2 FG 79.9 TW 72.6 TF 79.9 TW 73.3 TF 74.4FG 74.4 FG 79.9 TW 73.2 TF 79.9 TW 73.2 TF 74.6 FG 74.6 FG 74.8 FG 80.3 TW 73.6 TF 80.3 TW 73.0 TF 74.8 FG 75.1 FG 80.8 TW 73.3 TF 80.7 TW 74.0 TF 74.2FG 74.2 FG 74.0 FG 74.0 FG74.4 FG 74.4 FG74.6 FG 74.6 FG74.8 FG 74.8 FG75.0 FG 75.0 FG75.5 FG 75.5 FG 79.4 TW 73.4 TF 75.4 FG 0.1' DF 74.7 FG0.3' DF 74.7 FG 0.1' DF 74.4 FG0.2' DF 74.3 FG 0.1' DF 74.1 FG0.1' DF75.0 FG 75.5FG 74.7FG 75.0 FG 74.6FG 74.8 FG 74.4 FG 74.6 FG 74.2 FG 74.4 FG 74.0 FG 74.0 FG 79.4 TW 73.4 TF80.0TW 73.3TF 80.3 TW 73.3 TF 80.0 TW 73.3 TF 80.0 TW 73.3 TF 80.4 TW 73.7 TF 80.4 TW 73.7 TF 80.6 TW 73.9 TF 80.6 TW 73.9 TF 80.8 TW 74.1 TF 80.8 TW 74.1 TF81.4 TW 74.7 TF 81.4 TW 74.7 TF 75.5 FG 79.8 TW 73.1 TF 79.8 TW 73.1 TF 6 75.0 FG 75.5 FG 74.8FG 74.6 FG SEE SHT 3 SEE SHT 3 PUE80.3 TW 73.0 TF 74.8FG74.5 FG 80.3 TW 73.6 TF 79.9 TW 72.6 TF 74.4 FG 74.2 FG 79.9 TW 73.2 TF 73.8 FG 79.4 TW 72.1 TF 73.7 FG 79.4 TW 72.7 TF 80.0 TW 73.3 TF 74.4 FG 74.1 FG 80.0 TW 73.3 TF 73.9 FG 0.1' DF 6 6 6 6 6 6 4 6 6 6 2 6 6 6 6 6 6 80.7 TW 74.0 TF 80.9 TW 73.6 TF 75.1 FG 75.1 FG 80.8 TW 73.3 TF 80.3 TW 73.6 TF 73.8 FL 80.3 TW 73.6 TF 80.3 TW 73.0 TF 73.3 FL 79.9 TW 73.2 TF 79.9 TW 73.2 TF 79.9 TW 72.6 TF 79.9 TW 73.3 TF 79.9 TW 72.6 TF 3 3 3 3 4 4 4 4 4 3 4 3 4 4 73.5 FL 79.8 TW 73.1 TF 4 4 79.7 TW 73.1 TF 4 4 74.0 FG73.2 FL 79.8 TW 72.5 TF 79.8 TW 73.1 TF 4 79.4 TW 72.7 TF 79.4 TW 72.1 TF 79.4 TW 72.1 TF 79.4 TW 72.7 TF 79.4 TW 72.7 TF 43 3 4 80.0TW 73.3TF 80.0 TW 72.7 TF 80.0TW 72.7TF 3 4 4 80.0TW 72.7TF 80.0TW 72.7TF 80.0 TW 73.3 TF 80.0TW 72.7TF 4 3 4 3 80.4 TW 73.7 TF 80.4 TW 73.1 TF 80.4 TW 73.1 TF 63 4 80.6 TW 73.9 TF 80.6 TW 73.3 TF 80.6 TW 73.3 TF 4 4 6 3 80.8 TW 73.5 TF 80.8 TW 74.1 TF 80.8 TW 73.5 TF 4 4 3 81.4 TW 74.7 TF 81.4 TW 74.1 TF 40'10' 20'20'60' 20 Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig ANDERSON CONSULTING ENGINEERS, INC. EXP. 09/30/24 NO. C 48750 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 LEGEND LOT NUMBER TRACT BOUNDARY PHASE BOUNDARY EXISTING EASEMENT (SEWER/STORM) EXISTING EASEMENT (UTILITY) EXISTING LOT LINE SLOPE RETAINING WALL SANITARY SEWER POTABLE OR RECYCLED WATER STORM DRAIN 390 WALL AND FENCE PLAN WALL AND FENCE PLAN IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA SEPTEMBER 2022 CONSTRUCTION NOTES OMIT HALF BLOCK AT GRADE TO ALLOW FOR DRAINAGE PER DETAIL (SEE SHT. 3). 3 4 6 CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-0" (PER DETAIL 3 ON SHEET 7). CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-8" (PER DETAIL 3 ON SHEET 7). 11-15-22 122'-8 1/2" 11 4 ' - 6 1 / 2 " 8'-2" 7'-2" 7'-2" 8 0 8 1 8 2 8 3 8 4 79 8 5 78.2 FL 78.4 FL 25 24(77.47) TC (78.14) TC (77.55) TC 110.62' 31 . 6 3 ' 20.0 0 ' 117 . 7 8 ' 39.7 9 ' 91.85' 31.9 2 ' 30 . 6 5 ' 65 . 5 3 ' L = 3 7 . 1 2 L = 7 9 . 3 4 34. 3 5 ' 109.5 2 ' CL A R K E C O U R T 10' CONC. SWALE PER RG PLANS 6 3 3 1 EX. R O C K F A L L B A R R I E R 5' CONC. SWALE PER RG PLANS 2:1 SLOPE PER RG PLANS 83.9 T0P FENCE 78.1FG 78.2FG 78.1 FG 83.8 TW 77.1 TF 83.8 TW 77.1 TF 84.1 TW 77.4 TF 78.4 FG 79.2 FG 84.8 TW 77.5 TF 80.4 FG 79.2FG 79.5 FG 83.8 FG 85.0 FG 84.8 TW 78.1 TF 82.5 FG 80.5 FG 79.2 FG 79.5 FG 79.2 FG 79.0 FG PUE 6 2 79.2 FG 79.0FG 79.2 FG 85.3 TRW 81.3 TF74.8 FG 80.6 TRW 78.6 TF 80.0 FG 86.6 TW 81.3 TRW 79.3 TF 87.3 TW 80.6 TRW 78.6 TF 86.6 TW 81.3 TRW 79.3 TF 87.3 TW 82.0 TRW 79.3 TF 88.0 TW 82.0 TRW 79.3 TF 88.0 TW 82.7 TRW 79.3 TF 88.7 TW 82.7 TRW 79.3 TF 88.7 TW 83.3 TRW 80.0 TF 89.3 TW 83.3 TRW 80.0 TF 89.3 TW 84.0 TRW 80.7 TF 90.0 TW 83.3 TRW 80.7 TF 89.3 TW 84.7 TRW 81.3 TF 90.7 TW 91.3 TW 82.3 TRW 81.3 TF 89.3 TW 3 79.87 FF 79.2 PE 84.8 TW 78.1 TF 4 84.8 TW 78.1 TF 84.8 TW 78.1 TF 85.0 TW 77.7 TF 4 85.0 T 0 P FENC E 85.0 T 0 P FENC E 85.0 T0P FENCE 85.0 T0P FENCE 83.9 T0P FENCE 89.0 T0P FENCE 40'10' 20'20'60' 20 Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig ANDERSON CONSULTING ENGINEERS, INC. EXP. 09/30/24 NO. C 48750 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 LEGEND LOT NUMBER TRACT BOUNDARY PHASE BOUNDARY EXISTING EASEMENT (SEWER/STORM) EXISTING EASEMENT (UTILITY) EXISTING LOT LINE SLOPE RETAINING WALL SANITARY SEWER POTABLE OR RECYCLED WATER STORM DRAIN 390 WALL AND FENCE PLAN WALL AND FENCE PLAN IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA WALL FOOTING OMIT HALF BLOCK AT FLOWLINE OF PROPOSED SWALE TO PROVIDE OUTLET FOR YARD DRAINAGE 6'-8" FREE STANDING BLOCK WALL (PER DETAIL 3 ON SHEET 7) FL E L E V . PER P L A N WALL OPENING DETAIL NOT TO SCALE 0.5 P/L PAD FF FF 2% MIN 20% MAX VARIES VARIES 8" M I N 8" M I N VARIES 3' MIN FL VARIES 3' MIN 2% MIN 2:1 MAX FL 2% MIN 20% MAX 8" M I N 8" M I N 0.5' PAD 0.5 P/L PAD FF FF 2% MIN 20% MAX VARIES VARIES 8" M I N 8" M I N VARIES 3' MIN FL VARIES 3' MIN 2:1 MAX FL 2% MIN 20% MAX 8" M I N 8" M I N 0.5' PAD COMBINATION RETAINING/BLOCK WALL, 8' MAX. EXPOSED (PER DETAIL 2 ON SHEET 7) PAD 2% MIN 20% MAX 8" M I N EXIST. GROUND EXISTING BLOCK WALL VARIES (10'MAX) VARIES PL 8" M I N BLOCK WALL, 6' MAX. (PER DETAIL 3 ON SHEET 7) 2% MIN 20% MAX PAD ELEV. MINUS 0.3' (MIN.) FL PAD 2% MIN 20% MAX 8" M I N VARIES (10'MAX) VARIES PL 8" M I N 2% MIN 20% MAX PAD ELEV. MINUS 0.3' (MIN.) FL PROPOSED CHANNEL PER ROUGH GRADING PLANS 2:1 MAX COMBINATION BLOCK WALL/VIEW FENCE , 6' MAX. (PER DETAIL 1 ON SHEET 7) SEPTEMBER 2022 WALL NOTES 1. MAXIMUM WALL HEIGHT IS 6 FEET. COMBINATION WALLS MAY BE TALLER, BUT THE FREESTANDING PORTION SHALL NOT EXCEED 6 FEET. IF THE RETAINING WALL IS 3 FEET OR GREATER THE FREESTANDING PORTION SHALL NOT EXCEED 5 FEET. WALLS SEPARATED BY 3 FEET OR MORE ARE CONSIDERED INDEPENDENT. 2. PERIMETER WALLS SHALL MATCH THE WALLS EXITING IN THE COMMUNITY. CONSTRUCTION NOTES 1 2 OMIT HALF BLOCK AT GRADE TO ALLOW FOR DRAINAGE PER DETAIL HEREON. 3 CONSTRUCT COMBINATION BLOCK/VIEW FENCE (PER DETAIL 1 ON SHEET 7). 4 CONSTRUCT COMBINATION RETAINING/PRIVACY WALL, 8' MAX. (PER DETAIL 2 ON SHEET 7) 6 CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-0" (PER DETAIL 3 ON SHEET 7). CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-8" (PER DETAIL 3 ON SHEET 7). 11-15-22 76 . 0 0 F F 75 . 5 P E 77.1FL77.4 FL 77.2 FL 77.1 FL 76.3 FL 76.5 FL 75.3 FL 75.2FL 77.7 FL 76.8 FL 77.0 FL 76.1 FL 76.3 FL 74.6 FL 74.4 FL 75 . 2 FG / H P 75 . 1 FG 74 . 7 FG (7 4 . 9 8 ) TC (75.74) TC (74.98) TC(74.98) TC 1 . 4 6 % 0 . 5 % 0.5% PL N 1 40 41 4243 44 45 46 47 LOT K BASIN 26 39 20' 2 0 ' (7 5 . 1 5 ) TC (7 5 . 9 P E ) (7 7 . 5 P E ) 76 L=60.25 L =9 2 .7 9 L =8.0 7 (77.47) TC (77.19) TC (76.72) TC (76.76) TC(77.21) TC(77.20) TC (77.03) TC (76.85) TC(76.67) TC(76.49) TC(76.28) TC (76.18) TC (76.10) TC (75.89) TC (75.79) TC(75.74) TC (75.17) TC (74.74) TC (74.47) TC (73.98) TC(73.92) TC (78.14) TC 78.87 FF 78.1 PE 79.07 FF 78.4 PE 78.27 FF 77.6 PE 77.97 FF 77.3 PE 76.77 FF 76.1 PE 76.07 FF 75.4 PE 22.89'L =3 8.48 71 . 6 1 ' L = 3 7 . 1 2 L = 7 9 . 3 4 34 . 3 5 ' 109.5 2 ' 21.81 ' 51.67' 35.34'33.64'68.58'51.56' 87.61' 70.19' 20 7 . 1 8 ' L =1 0 7 .7 8 L =4 2 .5 6 L =7 1 .4 2 L =8 .2 9 L =1 9 .7 1 L =4 7 .5 9 L=14.36 L=19.71 38.28'34.84'L =3 4 .0 6 L =3 3 .8 3 L =3 6 .7 4 L =31 .21 20 3 . 7 9 ' 16 9 . 3 7 ' 15 4 . 9 8 ' 13 9 . 9 2 ' 16 3 . 9 0 ' 18 1 . 5 7 ' 20 6 . 4 0 ' 1.0% BRADSHAW TRAIL CL A R K E C O U R T CL A R K E C O U R T 0.7% R/W 1 8 . 5 ' 1 8 . 5 ' PUE R = 3 8 ' EX. SWR EX. WTR 10' CONC. SWALE PER RG PLANS 3 3 3 3 3 3 3 3 3 6 6 6 1 1 1 EX. ROCKFALL BARRIER 83.8 TW 77.1 TF 83.2 T0P FENCE 83.9 T0P FENCE 83.2 T0P FENCE 81.7 T0P FENCE 82.5 T0P FENCE 82.5 T0P FENCE 82.5 T0P FENCE 83.2 T0P FENCE 83.9 T0P FENCE 81.7 T0P FENCE81.0 T0P FENCE 81.0 T0P FENCE 78.1 FG 78.2 FG 78.1 FG 83.8 TW 77.1 TF 83.8 TW 77.1 TF 83.8 TW 77.1 TF84.1 TW 77.4 TF 78.1 FG 77.7 FG 0.4' DF 84.1 TW 77.4 TF 78.4 FG 78.4 FG 78.4FG 78.4 FG 78.0 FG78.0 FG 78.0 FG78.0 FG 77.6FG 77.6 FG 77.6 FG 77.6 FG 77.3 FG77.3 FG 77.3 FG 77.3FG 77.0 FG 77.0 FG 77.0 FG 77.0 FG 76.1 FG 76.1 FG 76.1FG 76.1FG 75.4 FG 75.4 FG 75.4FG 75.4FG 78.2 FG 0.2' DF77.8 FG 0.2' DF 75.2 FG0.2' DF 75.9 FG 0.2' DF 83.8 TW 77.1 TF 78.0 FG 77.6 FG 83.6 TW 77.1 TF 83.6 TW 76.1 TF 77.6 FG 83.0 TW 76.3 TF 83.0 TW 76.3 TF 77.3FG 82.8 TW 76.1 TF 82.8 TW 76.1 TF77.0 FG 82.0 TW 75.3 TF 82.0 TW 75.3 TF 76.1FG 81.3 TW 74.6 TF 81.3 TW 74.6 TF 75.4 FG 81.1 TW 74.4 TF 81.1 TW 74.4 TF SEE SHT 3 SEE SHT 3 77.6 FG 83.8TW 77.1 TF 83.8 TW 77.1 TF77.0 FG 77.6 FG 83.0 TW 76.3 TF77.0 FG 83.0 TW 76.3 TF 75.8 FG 82.0 TW 75.3 TF 82.0 TW 75.3 TF 6 666 6 6 6 6 6 6 6 84.8 TW 78.1 TF 78.1 FG 83.9 T0P FENCE 78.1 FG77.67 FF 77.0 PE 84.1 TW 76.7 TF 4 77.5FL 83.8 TW 76.5 TF 83.8 TW 76.5 TF 78.67 FF 78.0 PE 83.8 TW 77.1 TF 4 4 83.6 TW 76.1 TF 83.6 TW 76.1 TF 83.6 TW 76.1 TF 4 4 3 3 3 83.0 TW 75.7 TF 83.0 TW 76.3 TF 83.0 TW 75.7 TF 4 3 6 82.8 TW 75.5 TF 82.8 TW 75.5 TF 82.8 TW 76.1 TF 4 3 4 82.0 TW 75.3 TF 76.1FG 3 82.0 TW 74.6 TF4 3 81.3 TW 73.9 TF 81.3 TW 74.6 TF 75.4FG 4 3 81.1 TW 73.7 TF 4 WALL AND FENCE PLAN IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA 40'10' 20'20'60' 20 Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig ANDERSON CONSULTING ENGINEERS, INC. EXP. 09/30/24 NO. C 48750 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 LEGEND LOT NUMBER TRACT BOUNDARY PHASE BOUNDARY EXISTING EASEMENT (SEWER/STORM) EXISTING EASEMENT (UTILITY) EXISTING LOT LINE SLOPE RETAINING WALL SANITARY SEWER POTABLE OR RECYCLED WATER STORM DRAIN 390 WALL AND FENCE PLAN SEPTEMBER 2022 CONSTRUCTION NOTES 1 OMIT HALF BLOCK AT GRADE TO ALLOW FOR DRAINAGE PER DETAIL (SEE SHT. 3). 3 CONSTRUCT COMBINATION BLOCK/VIEW FENCE (PER DETAIL 1 ON SHEET 7). 4 6 CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-0" (PER DETAIL 3 ON SHEET 7). CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-8" (PER DETAIL 3 ON SHEET 7). 11-15-22 75.1 FL 71.3 FL 71.1 FL 71.4 FL 71.3 FL 71.5 FL 72.0 FL 71.0FL 71.3FL 71.7 FL 71.7 FL 73.0 FL 73.1 FL 72 71 70 6968 67 66 BRADSHAW TRAIL 72.77 FF 72.1 PE 72.77 FF 72.1 PE72.77 FF 72.1 PE 73.17 FF 72.5 PE 73.47 FF 72.8 PE 74.47 FF 73.8 PE 76.47 FF 75.8 PE (70.69) TC (70.32) TC (70.33) TC (70.57) TC (70.58) TC(70.95) TC (71.32) TC(71.44) TC (71.71) TC (72.46) TC (76.07) TC (74.65) TC R/WPUE 17 8 . 5 2 ' 15 6 . 5 1 ' 14 9 . 4 5 ' 15 9 . 3 3 ' 16 9 . 2 1 ' 15 2 . 6 0 ' 11 5 . 9 3 ' 95. 8 5 ' 72.88' 69.21' 69.21'69.54' 81. 6 3 ' 112.15 ' 11 2 . 2 3 ' L=95.07 L=72.27 L=52.80 16.01'68.50'68.50'8.91'L=60.35 L=17.31 EX. SWR EX. WTR EX. SD 5' CONC. SWALE PER RG PLANS 3 3 3 33 3 2 3 1 1 1 6 6 6 LOT G BASIN EX. ROCKFALL BARRIER 77.7 T0P FENCE 77.7 T0P FENCE 77.7 T0P FENCE 77.7 T0P FENCE78.3 T0P FENCE 77.7 TW 71.0 TF 78.3 T0P FENCE 78.3 T0P FENCE 79.0 T0P FENCE 79.0 T0P FENCE 81.0 T0P FENCE 72.0 FG 0.1' DF 78.0 TW 71.3 TF 72.1 FG 72.1FG 72.1 FG 71.9 FG 72.1 FG 72.1 FG 6 72.1 FG 72.1FG 78.0 TW 71.3 TF 78.0 TW 71.3 TF 72.1 FG 72.1FG 72.0 FG 0.1' DF 72.1 FG 78.0 TW 71.3 TF 0.5% 77.7 TW 71.1 TF 72.5 FG 72.5 FG 72.5 FG 72.5 FG 72.4 FG 0.1' DF 72.7 FG 0.1' DF 78.2 TW 71.5 TF 78.2 TW 71.5 TF 72.8 FG 72.8 FG 72.8FG 78.8 TW 72.1 TF 73.8 FG 73.7 FG0.1' DF 73.8FG 75.8 FG 73.8 FG 81.0 T0P FENCE 78.8 TW 72.1 TF80.4 TW 73.1 TF 75.8 FG 74.5 FG 75.8 TRW 73.8 TF 74.8 FG81.8 TW 2: 1 81.8 TW 75.1 TF 73.8 FG 75.8 FG 73.6 FG0.2' DF 81.0 TW 75.0 TF 75.8 FG 75.8 FG 81.0 TW 75.0 TF 3 4 SEE SHT 3 SEE SHT 3 SEE SHT 3 72.1 FG 77.7 TW 71.0 TF 77.7 TW 70.3 TF 71.8 FG 77.7 TW 70.4 TF 72.1 FG 71.6 FG 77.7 TW 71.1 TF78.2 TW 70.8 TF 72.3 FG 78.2TW 71.5 TF 80.4TW 73.1 TF 74.9 FG 74.9 FG 81.1TW 73.8 TF 6 6 6 6 6 6 6 6 6 2: 1 73.9 FL 77.7 TW 70.3 TF4 78.0 TW 71.3 TF 78.0 TW 70.6 TF 4 3 472.1 FG 78.0 TW 71.3 TF 78.0 TW 70.6 TF 78.0 TW 70.6 TF 4 3 477.7 TW 71.1 TF 77.7 TW 71.1 TF 72.1 FG 77.7 TW 70.4 TF 77.7 TW 71.1 TF 34 3 78.2 TW 71.5 TF 72.3FG 78.2 TW 70.8 TF 78.2 TW 70.8 TF 78.2 TW 71.5 TF 78.8 TW 71.4 TF 78.8 TW 72.1 TF 72.8FG 3 4 4 3 3 4 75.8 FG 81.8 TW 75.1 TF 75.8 TRW 73.8 TF 81.8 TW 75.1 TRW 73.1TF 81.1 TW 6 75.1 TRW 73.1TF 81.1 TW 79.8 TW 72.4 TF 81.1 TW 73.1 TF81.1 TW 73.8 TF 75.8 TRW 74.5 TF 81.8 TW 75.8 TRW 74.5 TF 81.8 TW 81.0 TW 75.0 TF 81.0 TW 74.3 TF 4 81.1 TW 73.1 TF 40'10' 20'20'60' 20 Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig ANDERSON CONSULTING ENGINEERS, INC. EXP. 09/30/24 NO. C 48750 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 LEGEND LOT NUMBER TRACT BOUNDARY PHASE BOUNDARY EXISTING EASEMENT (SEWER/STORM) EXISTING EASEMENT (UTILITY) EXISTING LOT LINE SLOPE RETAINING WALL SANITARY SEWER POTABLE OR RECYCLED WATER STORM DRAIN 390 WALL AND FENCE PLAN WALL AND FENCE PLAN IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA SEPTEMBER 2022 CONSTRUCTION NOTES 1 2 OMIT HALF BLOCK AT GRADE TO ALLOW FOR DRAINAGE PER DETAIL (SEE SHT. 3). 3 CONSTRUCT COMBINATION BLOCK/VIEW FENCE (PER DETAIL 1 ON SHEET 7). 4 CONSTRUCT COMBINATION RETAINING/PRIVACY WALL, 8' MAX. (PER DETAIL 2 ON SHEET 7) 6 CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-0" (PER DETAIL 3 ON SHEET 7). CONSTRUCT FREESTANDING BLOCK WALL, MAX. HEIGHT=6'-8" (PER DETAIL 3 ON SHEET 7). 11-15-22 71.0FL (70.69) TC 11 5 . 9 3 ' L=64.51 3 1 6 LOT G BASIN 77.7 T0P FENCE 77.7 TW 71.0 TF 72.0 FG 0.1' DF 71.9 FG 72.1 FG 77.7 TW 71.0 TF 77.7 TW 70.3 TF4 BOT=61.0 61 61 62 63 64 65 66 67 68 69 68 67 66 65 64 63 62 61 69 62 63 64 65 66 67 68 69 62.5 TRW 60.5 TF 6 3 . 2 T R W 6 0 . 5 T F 63.9 TRW60.5 TF64.5 TRW60.5 TF 65.2 TRW60.5 TF 65.9 TRW60.5 TF 66.5 TRW60.5 TF67.2 TRW61.2 TF67.2 TRW 61.8 TF67.2 TRW62.5 TF67.9 TRW63.2 TF6 7 . 9 T R W 63.9 TF67.9 TRW64.5 TF67.9 TRW65.2 TF6 7 . 9 T R W 6 5 . 9 T F 68.5 TRW66.5 TF6 8 . 5 T R W 67.2 TF69.2 TRW67.9 TF69.2 TRW68.5 TF 69.2 TRW68.5 TF 5 SEE HEREON 20'5' 10'10'30' 10 Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig ANDERSON CONSULTING ENGINEERS, INC. EXP. 09/30/24 NO. C 48750 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 LEGEND LOT NUMBER TRACT BOUNDARY PHASE BOUNDARY EXISTING EASEMENT (SEWER/STORM) EXISTING EASEMENT (UTILITY) EXISTING LOT LINE SLOPE RETAINING WALL SANITARY SEWER POTABLE OR RECYCLED WATER STORM DRAIN 390 WALL AND FENCE PLAN WALL AND FENCE PLAN IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA SEPTEMBER 2022 CONSTRUCTION NOTES 5 CONSTRUCT RETAINING WALL, MAX. HEIGHT=6'-0" (PER DETAILS ON SHEET 8). 10' RETAINING WALL, 6' MAX. (PER DETAILS ON SHEET 8) 2:1 S L O P E MAX. 6" P.C.C. ACCRSS ROAD (PER ROUGH GRADING PLANS) 2:1 S L O P E MAX. SEE ROUGH GRADING PLANS FOR BASIN GRADING 6" M I N 11-15-22 ’ Underground Service Alert Section 4216/4216.9 of the Government Code requires a DIG ALERT Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert I.D. Number Call Underground Service Alert 811 two working days before you dig WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC 8LOTS 1-7, 25, 33-38, 40-47, & 66-72 LONG BEACH, CA 90807 www.proto2.com 3612 CALIFORNIA AVE ATTN: MARIO SALAZAR PH# (562) 477-8529 PROTO-IITM WALL SYSTEMS U.S. PATENTED 7,188,453 U.S. PATENTED 7,454,870 U.S. PATENTED 7,461,487 U.S. PATENTED 5,794,921 U.S. PATENTED 6,431,797 U.S. PATENTED 6,632,048 msalazar@protoii.com PROTO-II WALL SYSTEMS MAY ONLY BE INSTALLED BY APPROVED AND CERTIFIED INSTALLERS 7 USE APPROVED WALL DETAIL ATTACHED TO PERMIT GENERAL NOTES 1. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE CONSTRUCTION DOCUMENTS AND SITE CONDITIONS BEFORE STARTING WORK. ALL DIMENSIONS ON THE STRUCTURAL DRAWINGS SHALL BE COMPARED TO THOSE ON THE ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. THE ARCHITECT OR ENGINEER OF RECORD SHALL BE NOTIFIED OF ANY DISCREPANCY. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. 2. IF ANY CONFLICTS ARISE BETWEEN THE ARCHITECTURAL SPECIFICATIONS AND THE STRUCTURAL SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 3. REFER TO ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR LOCATIONS OF FLOORS, ROOFS, WALLS, AND NON-STRUCTURAL ELEMENTS AND CONFIGURATIONS AND OPENINGS IN THESE ELEMENTS AND LOCATIONS OF TRENCHES, DEPRESSIONS, PIPES, EQUIPMENT, ETC. NOT SHOWN ON STRUCTURAL DRAWINGS. 4. GENERAL DETAILS AND GENERAL NOTES ARE MINIMUM REQUIREMENTS TO BE USED WHEN CONDITIONS ARE NOT SHOWN OTHERWISE. DETAILED NOTES AND DETAILED DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND GENERAL DETAILS. 5. WHERE NO DETAILS OR NOTES ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT AND SHALL BE IN CONFORMANCE WITH ACCEPTED TRADE STANDARDS. 6. ALL WORK SHALL CONFORM WITH THE STRUCTURAL NOTES, DETAILS, DRAWINGS, AND SPECIFICATIONS ALONG WITH ASSOCIATED NOTES, DETAILS, DRAWINGS, AND SPECIFICATIONS. 7. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE 2019 CALIFORNIA BUILDING CODE AND ANY OTHER AMENDMENTS AS ADOPTED BY THE LOCAL CITY, COUNTY, AND ANY OTHER REGULATING AGENCY HAVING AUTHORITY OVER ANY PORTION OF WORK. 8. ALL WORK SHALL CONFORM WITH APPLICABLE FEDERAL LAWS, STATE STATUTES, LOCAL ORDINANCES, AND THE REGULATIONS OF AGENCIES HAVING JURISDICTION. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR COMPLYING WITH THE CONSTRUCTION SAFETY ORDERS AND THE GENERAL INDUSTRIAL SAFETY ORDERS OF THE STATE DIVISION OF INDUSTRIAL SAFETY, THE REGULATIONS OF THE FEDERAL AND STATE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATIONS, AND SUCH OTHER AGENCIES GOVERNING THE CONTRACTOR'S ACTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND HOLD HARMLESS THE STRUCTURAL ENGINEER FOR ANY DAMAGES AND PENALTIES OR BOTH RESULTING FROM HIS FAILURE TO COMPLY WITH SAID LAWS, STATUTES, ORDINANCES, AND REGULATIONS. 9. THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. HE SHALL PROVIDE THE NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO THE APPLICATION OF THE AFOREMENTIONED MATERIALS. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER OR HIS DESIGNEE SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 10. CONSTRUCTION MATERIALS SHALL BE PLACED SO THAT THE LOAD DOES NOT EXCEED THE DESIGNED LOAD IF THE MATERIALS ARE TO BE PLACED ON FRAMED ROOF OR FLOORS. 11. NO SUBSTITUTIONS OR CHANGES SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE OWNER AND ENGINEER OF RECORD. REINFORCING STEEL 1. ALL REINFORCING BARS SHALL BE ASTM A 615 GRADE 40 FOR #3 BARS AND SMALLER. ALL REINFORCING BARS SHALL BE ASTM A 615 GRADE 60 FOR #4 BARS AND LARGER. ALL BARS SHALL BE DEFORMED. 2. WIRE FABRIC SHALL CONFORM TO ANSI/ASTM A 185, STEEL WELDED WIRE FABRIC, PLAIN, FOR CONCRETE REINFORCEMENT. 3. BEND REINFORCING COLD UNLESS OTHERWISE ACCEPTED BY THE ENGINEER OF RECORD. 4.SECURELY TIE ANCHOR BOLTS, REINFORCING STEEL, INSERTS, ETC. IN PLACE PRIOR TO POURING CONCRETE OR GROUT. 4. PLACEMENT OF REINFORCING STEEL NEED NOT BE INSPECTED BY A SPECIAL INSPECTOR. 5. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AT LEAST EQUAL TO THE DIAMETER OF THE BARS. COVER SHALL BE AS FOLLOWS: A.CAST AGAINST EARTH 3" B. CAST AGAINST FORM BELOW GRADE, #6 AND LARGER 2" #5 AND SMALLER 1 1/2" C. FORMED SLABS 1" D. SLABS ON GRADE (FROM TOP OF SLAB)1" E. COLUMNS AND BEAMS TO MAIN BARS 2" F. WALLS - EXPOSED TO WEATHER 2" NOT EXPOSED TO WEATHER, #11 AND SMALLER 1" #14 AND #18 1 1/2" G. STRESSING TENDON 1 1/2" INSPECTION PROGRAM: 1. STRUCTURAL INSPECTION: THE BUILDING OFFICIAL OR BUILDING INSPECTOR DESIGNATED BY THE BUILDING OFFICIAL SHALL INSPECT ALL STRUCTURAL ASPECTS OF THE PROJECT IN ACCORDANCE WITH THE BUILDING PERMIT AND THE PROVISIONS OF THE BUILDING CODE. 2. SPECIAL INSPECTION: A REGISTERED SPECIAL INSPECTOR SHALL PROVIDE INSPECTION DURING CONSTRUCTION ON THE FOLLOWING TYPES OF WORK: PORTION OF WORK REQUIRING INSPECTION CONTINUOUS PERIODIC DESCRIPTION, LOCATIONS, REMARKS, ETC. FIRM A. THE STATEMENT OF SPECIAL INSPECTION IS SUBMITTED IN FULFILLMENT OF THE REQUIREMENTS OF CBC/ LABC SECTION 1704 AND 1705. INCLUDED ARE: 1. SCHEDULE OF SPECIAL INSPECTIONS AND TEST APPLICABLE TO THIS PROJECT: a. SPECIAL INSPECTIONS PER SECTIONS 1704 AND 1705 b. SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE c. SPECIAL INSPECTIONS FOR WIND RESISTANCE 2. LIST OF TESTING AGENCIES AND OTHER SPECIAL INSPECTORS THAT WILL BE RETAINED TO CONDUCT THE TEST AND INSPECTIONS. B. SPECIAL INSPECTIONS AND TESTING WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND SECTIONS 1704, 1705, 1707, AND 1708 C. THE SPECIAL INSPECTORS MUST BE CERTIFIED BY THE APPROVING MUNICIPALITY TO PERFORM THE TYPES OF INSPECTION LISTED. D. IT IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR TO INFORM THE SPECIAL INSPECTION AGENCY PRIOR TO PERFORMING THE WORK WHICH REQUIRES SPECIAL INSPECTION. ALL WORK PERFORMED WITHOUT THE REQUIRED SPECIAL INSPECTION IS SUBJECT TO REMOVAL. E. EACH SPECIAL INSPECTOR SHALL OBSERVE THE WORK OF THE CONTRACTOR AND THE TAKING OF TEST SAMPLES FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. SPECIAL INSPECTORS SHALL KEEP RECORDS OF INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE ENGINEER-OF-RECORD. REPORTS SHALL INDICATE THAT THE WORK INSPECTED WAS DONE IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF THE DISCREPANCIES ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL AND THE ENGINEER-OF-RECORD PRIOR TO THE COMPLETION OF THAT PHASE OF WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE SPECIAL INSPECTIONS SHALL BE SUBMITTED AT A POINT IN TIME AGREED UPON BY THE PERMIT APPLICANT AND THE BUILDING OFFICIAL PRIOR TO THE START OF WORK. F. A CERTIFICATE OF SATISFACTORY COMPLETION OF EACH PORTION OF WORK REQUIRING SPECIAL INSPECTION MUST BE COMPLETED AND SUBMITTED TO THE BUILDING OFFICIAL AND TO THE ARCHITECT AND ENGINEER-OF RECORD. G. INSPECTIONS BY A SPECIAL INSPECTOR DOS NOT RELIEVE THE CONTRACTOR FROM ANY INSPECTIONS BY THE BUILDING OFFICIAL. CONCRETE ANCHORS 1. ANCHOR BOLTS, L-BOLTS, J-BOLTS, BARS, AND RODS SHALL CONFORM TO ASTM F 1554. THREADS MAY BE CUT INTO FULL SIZE BAR STOCK OR MAY BE ROLLED THREADS. WHEN GALVANIZING IS USED IT SHALL CONFORM TO ASTM A153. 2. SB AND SSTB ANCHOR BOLTS ARE SIMPSON STRONG-TIE COMPANY PRODUCTS (ICC ESR-2611/ LARR 25827). 3. SHOT-PINS SHALL BE HILTI COMPANY PRODUCTS (ICC ESR-2379/ LARR 25469). 4. CONCRETE SCREW ANCHORS (LARGE DIAMETER ANCHORS) SHALL BE TITEN HD, SIMPSON STRONG-TIE COMPANY PRODUCTS (ICC ESR-2713/ LARR 25741). WHEN NOTED ON CONSTRUCTION DOCUMENTS INSTALLATION SHALL BE INSPECTED BY A SPECIAL INSPECTOR IN ACCORDANCE WITH THE INSPECTION PROGRAM. 5. ADHESIVE ANCHORS (CHEMICAL ANCHORS) SHALL BE SET-XP EPOXY ADHESIVE, SIMPSON STRONG-TIE COMPANY PRODUCTS (ICC ESR-2508/ LARR 25744). WHEN NOTED ON CONSTRUCTION DOCUMENTS INSTALLATION SHALL BE INSPECTED BY A SPECIAL INSPECTOR IN ACCORDANCE WITH THE INSPECTION PROGRAM. 6. INSTALLATION OF THE LISTED PRODUCTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALTERNATIVES MAY BE USED ONLY WITH SPECIFIC APPROVAL OF THE STRUCTURAL ENGINEER, AND ONLY UPON SUBMITTAL OF A LISTING OF HARDWARE TO BE SUBSTITUTED. 7. INSTALLATION OF ADHESIVE ANCHORS SHALL BE CONTINUOUSLY INSPECTED BY A SPECIAL INSPECTOR. THE INSPECTOR SHALL OBSERVE THE WORK OF THE CONTRACTOR DURING THE INSTALLATION OF THE ADHESIVE ANCHORS FOR CONFORMANCE WITH THE APPLICABLE ICC REPORT, THE MANUFACTURER'S RECOMMENDATIONS, AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE BUILDING CODE. INSPECTION OF WORK BY A SPECIAL INSPECTOR SHALL NOT RELIEVE THE CONTRACTOR OF ANY INSPECTIONS BY THE BUILDING OFFICIAL. SOILS INSPECTION 1. THE SOILS ENGINEER AND THE CONTRACTOR SHALL VERIFY THAT THE SOILS REPORT RECOMMENDATIONS THAT THE STRUCTURAL FOUNDATION DESIGN IS BASED ON IS FOLLOWED. THE OWNER OR CONTRACTOR SHALL ARRANGE FOR OBSERVATION OF THE WORK BY THE SOILS ENGINEER. 2. THE SOILS ENGINEER OR INDIVIDUAL / FIRM DESIGNATED BY THE SOILS ENGINEER SHALL INSPECT AND DOCUMENT IN ACCORDANCE WITH THE SOILS REPORT THE WORK OF THE CONTRACTOR PRIOR TO PLACEMENT OF REINFORCEMENT OR CONCRETE. AS A MINIMUM, ALONG WITH THE REQUIREMENTS OF THE SOILS ENGINEER OR BUILDING OFFICIAL, THE FOLLOWING PORTIONS OF WORK REQUIRE SOILS INSPECTION: A. EXCAVATIONS AND THE PLACEMENT OF FILL FOR BUILDING PAD CONSTRUCTION. B. EXCAVATIONS FOR FOOTING CONSTRUCTION. C. UTILITY TRENCHES ARE PROPERLY BACKFILLED AND COMPACTED. D. DRILLED PILE HOLES. E.PLACEMENT OF SUB-DRAIN PIPE OR WEEP HOLES. F. PLACEMENT OF GRAVEL AND BACK-FILL BEHIND RETAINING WALLS. 3. THE SOILS ENGINEER SHALL PROVIDE THE DOCUMENTED INSPECTION REPORTS TO BUILDING OFFICIAL PRIOR TO FOUNDATION INSPECTION AND TO THE ARCHITECT AND ENGINEER OF RECORD TO SHOW CONFORMANCE WITH THE SOILS REPORT RECOMMENDATIONS. STRUCTURAL OBSERVATION 1. THE STRUCTURAL ENGINEER-OF-RECORD OR HIS DESIGNEE SHALL PROVIDE PERIODIC VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM FOR GENERAL CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS AT SIGNIFICANT CONSTRUCTION STAGES, AT COMPLETION OF THE STRUCTURAL SYSTEM, AND UPON COMPLETION OF ANY ADJUSTMENTS TO THE WORK OCCASIONED BY THE STRUCTURAL OBSERVER'S VISITS. THE CONTRACTOR SHALL CALL TO SCHEDULE THE STRUCTURAL OBSERVER FOR VISITS THE PROJECT. THE CLIENT/OWNER OF THE PROJECT SHALL BE RESPONSIBLE FOR RETAINING AND REIMBURSING THE STRUCTURAL OBSERVER. ENGINEER-OF-RECORD KYLE MORRIS, P.E. TELEPHONE (949) 502-5323 STAGE REQUIRING OBSERVATION: A. BEFORE FOUNDATION POUR. B. UPON COMPLETION OF FRAMING AND PRIOR TO INSULATION DRYWALL, EXTERIOR MATERIALS, OR ROOFING. C. UPON COMPLETION OF ANY THE WORK REFERENCED BY THE STRUCTURAL OBSERVER'S VISITS. WORK TO BE OBSERVED: A. ELEMENTS OF THE WORK TO BE OBSERVED INCLUDE BUT ARE NOT NECESSARILY LIMITED TO: MATERIALS OF CONSTRUCTION, EXCAVATION CONFIGURATION, REINFORCEMENT, FASTENERS, HARDWARE, DETAILS OF CONSTRUCTION AND WORKMANSHIP. B. ELEMENTS OF THE WORK TO BE OBSERVED INCLUDE BUT ARE NOT NECESSARILY LIMITED TO: ISSUES PREVIOUSLY ADDRESSED BY THE STRUCTURAL OBSERVER IN PRIOR VISITS. 2. THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING IF APPLICABLE. THE MEETING SHALL INCLUDE THE STRUCTURAL OBSERVER, THE CONTRACTOR, APPROPRIATE SUBCONTRACTORS, SPECIAL INSPECTORS AND OTHER INTERESTED PARTIES. THE PURPOSE OF THE MEETING WILL BE TO IDENTIFY ALL AREAS REQUIRED FOR STRUCTURAL OBSERVATION AND SCHEDULING OF THE STRUCTURAL OBSERVATIONS 3. AT THE CONCLUSION OF THE WORK INCLUDED IN THE PERMIT, THE STRUCTURAL OBSERVER WILL SUBMIT TO THE BUILDING OFFICIAL A WRITTEN STATEMENT THAT THE SITE VISITS HAVE BEEN MADE AND OF HIS OBSERVATIONS AND SPECIFICS AS TO FINDINGS AND RECOMMENDATIONS. THE BUILDING OFFICIAL SHALL NOT BE CALLED FOR ANY INSPECTIONS UNTIL THE STRUCTURAL OBSERVATIONS OF THE REQUIRED PORTIONS OF WORK HAVE BEEN COMPLETED AND THE STATEMENT HAS BEEN ISSUED. 4. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY OF THE CONTRACTOR FROM OBTAINING OTHER REQUIRED INSPECTIONS. WORK MUST NOT BE COVERED UNTIL EACH PARTY IS ABLE TO MAKE INSPECTIONS OR OBSERVATIONS. 5. STRUCTURAL OBSERVATIONS IS MADE ONLY TO ASSIST THE CONTRACTOR IN COMPLYING WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS AND AS NECESSARY TO PROVIDE THE STRUCTURAL ENGINEER-OF-RECORD AN OPPORTUNITY TO MAKE A DETERMINATION IN HIS PROFESSIONAL OPINION THAT THE WORK OBSERVED WAS CONSTRUCTED IN GENERAL CONFORMANCE WITH THE INTENT OF THE STRUCTURAL CONSTRUCTION DOCUMENTS. OBSERVATION OF THE WORK IS IN GENERAL CONFORMANCE WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS DOES NOT CONSTITUTE A WARRANTEE; EITHER EXPRESSED OR IMPLIED THAT THE WORK IS IN FACT IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS OR THE BUILDING CODE. OBSERVATIONS OF THE WORK DO NOT RELIEVE THE CONTRACTOR OF THEIR RESPONSIBILITY FOR THE QUALITY OF THE WORK AND FOR ADHERING TO THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS OF THE BUILDING CODE. STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING ASTM STANDARDS UNLESS NOTED OTHERWISE. ALL STRUCTURAL STEEL U.N.O. BELOW ASTM A36 STEEL PIPES ASTM A53, GRADE-B (35 KSI) STRUCTURAL TUBES ASTM A500, GRADE-B (46 KSI) MACHINE BOLTS / ANCHOR BOLTS ASTM A307 NUTS FOR MACHINE BOLTS ASTM A563, HEX GRADE-A HIGH STRENGTH BOLTS ASTM A325 NUTS FOR HIGH STRENGTH BOLTS ASTM A563, HEAVY HEX GRADE-C 2. STRUCTURAL STEEL FURNISHED SHALL BE PROPERLY IDENTIFIED FOR CONFORMITY TO THE ORDERED GRADE IN ACCORDANCE WITH THE SPECIFIED ASTM STANDARDS. 3. STRUCTURAL STEEL FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH AISC 360, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS. 4. WELDING SHALL CONFORM WITH AWS D1.1 STANDARDS. WELDING SHALL BE PERFORMED BY WELDERS HAVING A CURRENT CERTIFICATE AS REQUIRED BY THE GOVERNING AUTHORITY. WELDS IDENTIFIED AS REQUIRING SPECIAL INSPECTIONS NEED NOT HAVE SPECIAL INSPECTION WHEN THE WELDING IS DONE IN AN APPROVED FABRICATOR'S SHOP. THE APPROVED FABRICATOR MUST SUBMIT A CERTIFICATE OF COMPLIANCE OF COMPLIANCE TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS PRIOR TO THE ERECTION OF THE PREFABRICATED COMPONENTS. 5. ALL FIELD WELDING SHALL BE CONTINUOUSLY INSPECTED AS NOTED IN THE INSPECTION PROGRAM. PRIOR TO THE START OF WORK THE THE SPECIAL INSPECTOR SHALL CHECK WELDER QUALIFICATIONS AND VERIFY THAT WELDING PROCEDURE SPECIFICATIONS HAVE BEEN APPROVED AND ARE APPLICABLE TO THE WORK INTENDED. 6. ALL WELDS TO BE E70XX. 7. ALL FULL PENETRATION GROVE WELDS FOR DUCTILE MOMENT FRAME MEMBERS SHALL BE ULTRASONICALLY INSPECTED BY AN APPROVED TESTING AGENCY AND SHALL CONFORM TO AWS D1.1. 8. HIGH STRENGTH BOLTING SHALL BE PERIODICALLY INSPECTION AS NOTED IN THE INSPECTION PROGRAM. STRUCTURAL DESIGN CRITERIA: STRUCTURAL DESIGNS ARE BASED ON THE 2019 CALIFORNIA BUILDING CODE PER THE FOLLOWING DESIGN LOADS AND PROCEDURES: 1. WIND DESIGN DATA: BASIC WIND SPEED (3 SECOND GUST) 94 MILES PER HOUR RISK OCCUPANCY CATEGORY II WIND EXPOSURE C BUILDING CATEGORY ENCLOSED BUILDING COMPONENT AND CLADDING 3. EARTHQUAKE DESIGN DATA: SEISMIC IMPORTANCE FACTOR____________________________1.00 RISK OCCUPANCY CATEGORY II MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss = 1.60 , S1 = 0.64 SITE CLASS D SPECTRAL RESPONSE COEFFICIENTS SDS = 1.28 , Sd1 = 0.71 SITE WORK AND FOUNDATIONS 1. THE FOUNDATION DESIGN IS BASED ON AN ALLOWABLE SOIL BEARING CAPACITY OF 1500 PSF. 2. THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE CLEAN, LEVEL, AND FREE OF LOOSE MATERIAL OR WATER WHEN CONCRETE IS PLACED. OVER EXCAVATION FOR THE FOOTINGS SHALL BE FILLED WITH CONCRETE. BACK FILL SHALL NOT BE PLACED UNTIL SUPPORTING FOUNDATIONS, WALLS, AND SLAB HAVE ATTAINED SUFFICIENT STRENGTH TO SUPPORT LATERAL SOIL PRESSURES. 3. THE SOIL UNDER FOOTINGS AND SLABS SHALL BE NEAR OPTIMUM MOISTURE CONTENT OR PRESATURATED PER THE SOILS REPORT RECOMMENDATIONS PRIOR TO CONCRETE PLACEMENT AND SHALL BE VERIFIED BY THE SOILS ENGINEER IN WRITING. BACK FILL IN CONTACT WITH FOUNDATIONS SHALL BE PLACED AS QUICK AS POSSIBLE. EXCAVATIONS AROUND THE BUILDING SHALL BE KEPT DRY AND STANDING WATER SHALL BE PUMPED OUT PRIOR TO PLACING BACK FILL. 4. THERE SHALL NOT BE ANY UTILITY TRENCHES WHICH EXTEND DEEPER THAN A 45 DEGREE LINE PROJECTED DOWN AND AWAY FROM THE BOTTOM OUTSIDE CORNER OF ANY FOOTING OF THE BUILDING FOUNDATION. THERE SHALL NOT BE ANY PIPES OR CONDUITS PLACED UNDER CONTINUOUS OR ISOLATED SPREAD FOOTINGS UNLESS DETAILED OR APPROVED BY THE ARCHITECT, ENGINEER OF RECORD, AND THE BUILDING OFFICIAL. 5. ALL SURFACE WATER MUST DRAIN AWAY FROM SLAB AND NO PONDING SHALL BE ALLOWED NEXT TO FOUNDATION. REFER TO CIVIL AND ARCHITECTURAL PLANS FOR DRAINAGE REQUIREMENTS. 6. VAPOR BARRIER (RETARDER) SHALL BE HIGH-DENSITY POLYETHYLENE PLASTIC FILM AND SHALL CONFORM TO ASTM E 1745, "WATER VAPOR RETARDERS USED IN CONTACT WITH SOIL OR GRANULAR FILL UNDER CONCRETE SLABS." 7. ALL HOLD DOWNS, ANCHORS BOLTS, AND POST BASES SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. 8. WORKMANSHIP DURING THE PLACING AND FINISHING OPERATIONS AND PROTECTION DURING THE CURING OF THE FOUNDATIONS SHALL BE SUCH THAT THE RESULTING CURED CONCRETE SHALL BE FREE OF SIGNIFICANT CRACKS OR SIGNIFICANT VERTICAL DISPLACEMENT. CONCRETE 1. ALL FINE AND COARSE AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL COMPLY WITH ASTM C33. THE SHRINKAGE SHALL BE PER ASTM C-157 WITH AVERAGE DRYING SHRINKAGE OF LESS THAN 0.05% AT 28 DAYS. 2. PROVIDE TYPE II OR V PORTLAND CEMENT CONFORMING TO ASTM C-150. 3. PROVIDE NORMAL WEIGHT CONCRETE ATTAINING A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: A. ALL SLAB-ON-GRADE 2500 PSI B . ALL CONTINUOUS FOOTINGS AND PADS 2500 PSI 4. ALL CONCRETE SHALL HAVE A MAXIMUM SLUMP OF 4", EXCEPT THAT THE SLUMP MAY BE INCREASED BY 1" WHEN HAND CONSOLIDATED. ALL CONCRETE SHALL HAVE A MAXIMUM WATER CEMENT RATIO OF 0.62. 5. THE FOLLOWING SHALL BE ADDITIONAL REQUIREMENTS FOR CONCRETE EXPOSED TO SULFATES FOR SLAB-ON-GRADES AND FOUNDATIONS: NOTE: A. A LOWER WATER-CEMENTITIOUS MATERIAL RATIO OR HIGHER STRENGTH CONCRETE MAY BE REQUIRED FOR LOW PERMEABILITY OR FOR PROTECTION AGAINST CORROSION OF EMBEDMENT ITEMS OR FREEZING AND THAWING. B. WATER SHALL BE CLEAN, FREE OF DELETERIOUS AMOUNT OF ACIDS, ALKALIS, OR ORGANIC MATERIALS. 6. FLY ASH OR POZZOLANS, IF USED, SHALL CONFORM WITH ASTM C 618, CLASS F. USAGE SHALL NOT EXCEED 25 PERCENT, BY WEIGHT OF THE TOTAL OF THE CEMENTITIOUS MATERIALS. POZZOLANS THAT ARE USED SHALL HAVE BEEN DETERMINED BY TEST OR SERVICE RECORD TO IMPROVE SULFATE RESISTANCE WHEN USED IN CONCRETE CONTAINING TYPE V CEMENT. POZZOLAN USAGE SHALL NOT BE LESS THAN 15 PERCENT, BY WEIGHT, OF THE TOTAL CEMENTITIOUS MATERIALS. 7.READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94-81. 8. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT. 9. DO NOT USE CONCRETE OR GROUT CONTAINING CHLORIDES. 10. EXCEPT FOR WHERE COLD JOINTS ARE NOTED ON PLANS, CONCRETE SHALL BE POURED MONOLITHICALLY. WHEN PLACEMENT CONSISTS OF MULTIPLE BATCHES OR TRUCK DELIVERY'S, THE WORK SHALL BE SCHEDULED SO THAT EACH BATCH IS PLACED WHILE THE PRECEDING ONE IS STILL PLASTIC. IF THE PRECEDING BATCH PLACEMENT HAS JUST STIFFENED BEYOND THE POINT WHERE IT CAN BE PENETRATED BY VIBRATION, BOND MAY BE ACHIEVED BY THOROUGHLY AND SYSTEMATICALLY VIBRATING THE SUBSEQUENT BATCH INTO CONTACT WITH THE PROCEEDING BATCH. 11. WHERE NEW CONCRETE IS PLACED AGAINST EXISTING (2-POUR) OR WHERE A MASONRY WALL INTERSECTS CONCRETE, ROUGHEN CONCRETE SURFACE TO A FULL AMPLITUDE OF 1/16". 12. ALL CONCRETE WITH A 28 DAY STRENGTH GREATER THAN 2500 PSI SHALL HAVE SPECIAL INSPECTION PER THE INSPECTION PROGRAM UNLESS NOTED OTHERWISE. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE ENGINEER WHEN SPECIAL INSPECTION IS REQUIRED. THE FOLLOWING ARE THE REQUIREMENTS OF THE SPECIAL INSPECTOR: A. HE SHALL VERIFY THE TAKING OF TEST SAMPLES. B. HE SHALL VERIFY SLUMP. C. HE SHALL VERIFY THE VARIOUS TYPES AND CLASSES OF CONCRETE USED. HE SHALL VERIFY LOAD TICKETS. D. HE SHALL VERIFY THAT CONSTRUCTION DETAILS, PROCEDURES, AND WORKMANSHIP ARE IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND BUILDING CODE. E. HE SHALL VERIFY THAT PROPER CURING PROCEDURES ARE IMPLEMENTED. 13. TESTING OF CONCRETE: A. TESTS NEED NOT BE MADE AS NOTED ABOVE PROVIDED THE TOTAL QUANTITY OF CONCRETE PLACED IS LESS THAN FIFTY (50) CU. YD. IN PLACE OF THE TESTS, A LETTER OF CERTIFICATION SHALL BE FURNISHED BY THE MATERIAL SUPPLIER TO THE BUILDING OFFICIAL, ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO DELIVERY OF THE MATERIALS TO THE JOB SITE. THE LETTER SHALL ASSURE THAT THE CONCRETE WILL HAVE THE STRENGTH SPECIFIED. B. TESTS SHALL BE MADE WHEN TESTING IS NOTED ABOVE OR WHERE THE TOTAL QUANTITY OF CONCRETE PLACED IS GREATER THAN FIFTY (50) CU. YD. CONCRETE TEST CYLINDERS SHALL BE TAKEN AND TESTED IN ACCORDANCE WITH ASTM C 31, & ASTM C 39. A CYLINDER SET IS A SET OF TWO (2) CYLINDERS FROM EACH BATCH OF CONCRETE SAMPLED. CYLINDER SETS SHALL BE SAMPLED AT A RATE OF NOT LESS THAN ONE (1) SET PER CLASS OF CONCRETE PLACED PER DAY, NOR LESS THAN ONE SET PER 150 CU. YD. PLACED, NOR LESS THAN ONE SET PER 5000 SQ. FT. OF SLAB OR WALL AREA. FURTHER NO LESS THAN FIVE (5) CYLINDERS SETS SHALL BE MADE OF EACH CLASS OF CONCRETE OR SHOULD THE TOTAL NUMBER OF BATCHES FOR A GIVEN CLASS OF CONCRETE BE LESS THAN FIVE (5), ONE (1) CYLINDER SET SHALL BE MADE FOR EACH BATCH PLACED. TEST RESULTS SHALL BE FURNISHED TO THE BUILDING OFFICIAL, ARCHITECT, AND STRUCTURAL ENGINEER. TEST RESULTS SHALL ASSURE THAT THE CONCRETE CYLINDERS ACHIEVE A MINIMUM STRENGTH SPECIFIED. 0.45 0.45 0.50 -- OVER 2.00 0.20 - 2.00 0.10 - 0.20 0.00 - 0.10 SEVERE VERY SEVERE MODERATE NEGLIGIBLE EXPOSURE SULFATE -- II or V V W/ POZZOLAN V CEMENT TYPE MIN. STRENGTH 28 DAY 4000 PSI 4500 PSI 4500 PSI WATER-SOLUBLE SULFATE S04 IN SOIL, PERCENTAGE BY WEIGHT -- MAX WATER- CEMENTITIOUS MATERIAL RATIO BY WEIGHT CONCRETE MASONRY UNITS 1. MATERIALS USED IN THE CONSTRUCTION OF CONCRETE MASONRY UNIT WALLS SHALL BE PER THE FOLLOWING STANDARDS: A. CONCRETE MASONRY UNITS (NORMAL WEIGHT)ASTM C 90. B. AGGREGATES FOR MORTAR ASTM C 144. C. AGGREGATES FOR GROUT ASTM C 404. D. MASONRY CEMENT ASTM C 91a. E. MORTAR CEMENT ASTM C 1329. F. PORTLAND CEMENT ASTM C 150. G. HYDRATED LIME ASTM C 207. 2. WATER SHALL BE CLEAN, FREE FROM DELETERIOUS AMOUNTS OF ACIDS, ALKALIE, AND ORGANIC MATERIALS. 3. CONCRETE MASONRY ASSEMBLAGES NOTED ON THE PLANS AS NOT REQUIRING SPECIAL INSPECTION SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE FOLLOWING: A. CONCRETE BLOCK SHALL BE CERTIFIED. A LETTER OF CERTIFICATION SHALL BE FURNISHED BY THE MATERIAL SUPPLIER TO THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER-OF-RECORD PRIOR TO DELIVERY OF THE MATERIALS TO THE JOB SITE. THE LETTER SHALL ASSURE THAT THE MATERIALS CONFORM TO ASTM C 90. B. MORTAR SHALL BE TYPE S AND HAVE BEEN MIXED IN ACCORDANCE WITH THE IBC TABLE 2103.7(1). THE MORTAR MIX SHALL ACHIEVE A 28 DAY STRENGTH OF 1800 PSI. C. GROUT SHALL BE MIXED IN ACCORDANCE TO IBC TABLE 2103.10 AND SHALL CONFORM TO ASTM C 476. THE GROUT MIX SHALL ACHIEVE A 28 DAY STRENGTH OF 2000 PSI. A LETTER OF CERTIFICATION SHALL BE FURNISHED BY THE MATERIAL SUPPLIER TO THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER-OF-RECORD PRIOR TO DELIVERY OF THE MATERIALS TO THE JOB SITE. D. CONSTRUCTION OF CONCRETE MASONRY WALLS NEED NOT BE INSPECTED BY A SPECIAL INSPECTOR. 4. CONCRETE MASONRY ASSEMBLAGES NOTED ON THE PLANS AS REQUIRING SPECIAL INSPECTION SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE FOLLOWING: A. CONCRETE BLOCK SHALL BE TESTED. TESTS OF THE BLOCKS SHALL BE MADE IN CONFORMANCE TO ASTM C 140. TESTS SHALL BE MADE OF THE BLOCKS PRIOR TO THE START OF CONSTRUCTION AND DURING THE COARSE OF CONSTRUCTION AT THE RATE OF ONE TEST PER 5000 SQ. FT. OF WALL. TEST RESULTS SHALL BE FURNISHED TO THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER-OF-RECORD. A MINIMUM NET COMPRESSIVE STRENGTH OF 1900 PSI SHALL BE SHOWN TO HAVE BEEN ACHIEVED. B. MORTAR SHALL BE TYPE S AND HAVE BEEN MIXED IN ACCORDANCE WITH THE IBC TABLE 2103.7(1). THE MORTAR MIX SHALL ACHIEVE A 28 DAY STRENGTH OF 1800 PSI. C. GROUT SHALL BE MIXED IN ACCORDANCE TO IBC TABLE 2103.10 AND SHALL BE PER ASTM C 476. THE GROUT MIX SHALL ACHIEVE A 28 DAY STRENGTH OF 2000 PSI. TESTS OF THE GROUT SHALL BE PER ASTM C 1019. TESTS SHALL BE MADE OF THE GROUT DURING THE COARSE OF CONSTRUCTION AT THE RATE OF ONE TEST PER 5000 SQ. FT. OF WALL. TEST RESULTS SHALL BE FURNISHED TO THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER-OF-RECORD PRIOR TO DELIVERY OF THE MATERIALS TO THE JOB SITE. D. CONSTRUCTION OF CONCRETE MASONRY WALLS SHALL BE INSPECTED BY A SPECIAL INSPECTOR. 5. FABRICATION AND PLACEMENT OF REINFORCING STEEL STEEL, EMBEDDED ANCHORS, AND HARDWARE SHALL BE PERIODICALLY INSPECTED BY A SPECIAL INSPECTOR WHEN PLACEMENT OF THE CONCRETE MASONRY ASSEMBLAGES IS REQUIRED TO BE INSPECTED BY A SPECIAL INSPECTOR. THE FOLLOWING ARE THE REQUIREMENTS OF THE SPECIAL INSPECTOR TO VERIFY: A.THE MILL CERTIFICATE. B. THE MATERIALS USED ARE PROPERLY STORED AND PREPARED FOR USE. C. THE CONSTRUCTION DETAILS, PROCEDURES, AND WORKMANSHIP ARE PER THE PLANS AND THE BUILDING CODE. D. THE REINFORCEMENT BAR GRADES, SIZE, PLACEMENT, AND SPLICES. A CERTIFICATE OF INSPECTION SHALL BE PROVIDED BY THE SPECIAL INSPECTOR TO THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER-OF-RECORD. 6. PLACEMENT OF CONCRETE MASONRY ASSEMBLAGES SHALL BE CONTINUOUSLY INSPECTED BY A SPECIAL INSPECTOR WHEN SPECIAL INSPECTIO IS NOTED AS BEING REQUIRED. THE INSPECTOR SHALL BE PRESENT DURING PREPARATION AND TAKING OF ANY PRISMS OR TEST SPECIMENS, AT THE START OF LAYING UNITS EACH DAY, AFTER THE PLACEMENT OF REINFORCING STEEL TO INSPECT THE GROUT SPACE PRIOR TO EACH GROUTING OPERATIONS. HE NEED NOT BE PRESENT DURING THE ENTIRE LAYING OPERATION PROVIDED HE IS PRESENT AT THE ONSET OF EACH DAYS WORK. THE FOLLOWING ARE THE REQUIREMENTS OF THE SPECIAL INSPECTOR TO VERIFY: A. THE TAKING OF TEST SAMPLES. B. THE MATERIALS USED ARE PROPERLY STORED AND PREPARED FOR USE. C. THE CONCRETE MASONRY UNITS ARE IN PER THE PLANS AND THE BUILDING CODE. D. THE MORTAR IS PROPERLY PREPARED AND PLACED PER THE PLANS AND THE BUILDING CODE. E. THE GROUT USED AND PLACED IS PER THE PLANS AND THE BUILDING CODE. HE SHALL VERIFY LOAD TICKETS FOR TRANSIT MIXED GROUTS. F. THE CONSTRUCTION DETAILS, PROCEDURES, AND WORKMANSHIP ARE PER THE PLANS AND THE BUILDING CODE. A CERTIFICATE OF INSPECTION SHALL BE PROVIDED BY THE SPECIAL INSPECTOR TO THE BUILDING OFFICIAL, ARCHITECT, AND ENGINEER-OF-RECORD. 7. CELLS SHALL BE IN VERTICAL ALIGNMENT TO PROVIDE A MINIMUM UNOBSTRUCTED CORE OF 3"X3". DOWELS FROM FOOTINGS SHALL BE SET TO ALIGN WITH CORES CONTAINING REINFORCING. 8. ALL CELLS CONTAINING REINFORCING, ANCHORS OR INSERTS SHALL BE FILLED SOLID WITH GROUT. OTHER CELLS SHALL BE FILLED WITH GROUT WHEN NOTED ON THE PLANS. UN-GROUTED CELLS SHALL BE BLOCKED WITH A GROUT STOP FABRIC TO PREVENT THEM FROM BEING INADVERTENTLY GROUTED. 9. CLEAN OUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE FILLED AT EACH LIFT OR POUR OF GROUT WHERE SUCH LIFT OR POUR IS IN EXCESS OF 5 FEET IN HEIGHT. OVERHANGING MORTAR OR OTHER OBSTRUCTION OR DEBRIS SHALL BE REMOVED FROM INSIDE OF CELL WALLS. CLEAN OUTS SHALL BE SEALED AFTER INSPECTION, BEFORE GROUTING. 10. HOLD VERTICAL REINFORCING IN POSITION AT TOP AND BOTTOM AND AT INTERVALS NOT EXCEEDING 200 BAR DIAMETERS IN MASONRY WALLS. 11. ALL ANCHOR BOLTS AND INSERTS SHALL BE SECURED IN PLACE PRIOR TO PLACEMENT OF CONCRETE OR GROUT. BAR SIZE CONCRETE LAP LENGTH MASONRY LAP LENGTH #4 #5 #6 #7 #8 41" 51" 61" 89" 102" 21" 39" 47" 68" 78" BAR BENDS STANDARD HOOKS 90° BEND 180° BEND STIRRUP AND TIE HOOKS BAR SIZE MIN. DIAMETER (D) NO. 3 THROUGH NO. 8 6d 8d 10d D 4d OR 2-1/2" MIN D D D 12d 45° BEND NO. 14 AND NO. 18 NO. 9, NO. 10, AND NO. 11 90° BEND D 6d AT NO. 5 AND SMALLER 12d AT NO. 6, 7, AND 8 135° BEND D 6d AT NO. 8 AND SMALLER "d " "d" "d" "d " LAP LENGTH 1" C L R . 6 1 TYP. LAP SPLICE CONCRETE EMBEDMENT WITH HOOKSTRAIGHT BAR 12" 13" 16" 18" 21" 12" 18" 24" 33" 43" HOOK BAR AT FOOTING INTERSECTION INTERSECTIONS HOOK BAR AT ENDS AT ENDS HOOK BAR INTERSECTIONS HOOK BAR AT CORNER, SINGLE BAR INTERSECTION, SINGLE BAR CORNER, DOUBLE BAR INTERSECTION, DOUBLE BAR REINF. PER PLAN HOOK BARS TO FAR SIDE OF FOOTING REINF. PER PLAN HOOK BARS TO FAR SIDE OF FOOTING CONT. CONC. FTG. OR WALL CONT. CONC. FTG. OR WALL C A STEP FOOTING FOOTING DEPTH PER SCHEDULE "A" HEIGHT OF STEP H = 2'-0" MAX. MATCH FT'G DEPTH 18" MIN. 2 TIMES "H" MIN. B GRADING FOOTING 2 1 2 1 IMAGINARY POINT OF REFERENCE (1'-0" ABOVE) BOTTOM OF EXCAVATION CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE SIDE OF ALL TRENCHES AND EXCAVATIONS FROM CAVING IN UNTIL ALL BACKFILLING IS COMPLETE. BACKFILL AS REQ'D BY SOILS REPORT OR CIVIL ENGINEER'S DRAWINGS. MAINTAIN SOIL AT SIDE OF FOOTING BOTTOM OF TRENCH OR EXCAVATION SHALL NOT EXTEND BELOW THIS LINE WHERE UTILITIES PASS BELOW PERIMETER FOUNDATION BACK FILL WITH NATIVE SOIL OR CONCRETE FROM FOUNDATION POUR TRENCHING FOUNDATION SLOPING GRADE POINT OF DAYLIGHT IMAGINARY POINT OF REFERENCE (1'-0" ABOVE BOTTOM OF EXCAVATION) FOOTING SETBACK TO SLOPE CAUTION: NOTE: CONTRACTOR RESPONSIBLE FOR PREVENTING TRENCH FROM CAVING IN. D 10'-0" MIN. E 10'-0" MIN. 1' - 0 " FOOTING WALL IMAGINARY POINT OF REFERENCE (1'-0" ABOVE BOTTOM OF EXCAVATION) POINT OF DAYLIGHT * SETBACK TO SLOPE U.N.O. 56' RETAINING WALL (BASIN 1) 12" MIN. 6'-6" EMBED FIRST COURSE OF BLOCK 2" INTO FOUNDATION (WET SET) PERFORATED PIPE DRAIN W/ GRAVEL IS REQ'D. SEE CIVIL DWG'S. #4 HORIZ. AT 24" O.C. 5'-3" 1'-0" CLR. 1'-0" CLR. (2)#4 AT TOP OF RETAINED SOIL #5 VERT. BARS AT 16" O.C. CONCRETE FTG 8" BLOCK WALL. SOLID GROUT. NO SPECIAL INSPECTION REQ'D. WATERPROOFING BY OTHERS 2-3/4" #4 AT 8" O.C. PROVIDE ADDITIONAL #4 BARS AT 16" O.C. BETWEEN DOWEL BARS F.G. 1 2 1'-3" 12" (5) #4 CONT. BARS 24 " 6" MIN. 12" MAX. #5 DOWEL AT 16" O.C. 6" MIN. #4 BARS 81401 DOVE STREET, SUITE 520 NEWPORT BEACH, CA 92660 PH: (949) 502-5323 WALL AND FENCE PLANS AMENDED TRACT NO. 31348 A POR. OF S.W. 1/4 OF SECTION 19 & N.W. 1/4 OF SECTION 30, T.5S., R.7E. S.B.M. CITY OF LA QUINTA FOR:WH LA QUINTA 29 LLC LOTS 1-7, 25, 33-38, 40-47, & 66-72 STRUCTURAL NOTES & DETAILS 8 FOUNDATION PLAN 1A SCALE: 1/4"=1'-0" FOUNDATION PLAN EXERCISE OPT. SCALE: 1/4"=1'-0" PARTIAL BDRM. 2 BA. 2 BDRM. 3 BA. 3 FLEX RM. W.I.C. P. BATH HALL P. BDRM. OUTDOOR RM. SERVICE KITCHEN DINING GREAT RM. FOYER PWDR. P. D.Z. 2-BAY GARAGE 1-BAY GARAGE CVRD. ENTRY S L O P E 4:1 2 BDRM. 2 BA. 3 W.I.C. P. BATH HALL M. PWDR. S L O P E 4:1 2 26 80 FR . D O O R T. G . 2 16'-0" 28' - 0 " 28' - 0 " 2 10'-6" 4 3'-5" 6 8' - 0 " 48' - 0 " 6 5'-1" 6 5'-1" 2 8' - 0 " 2 8' - 0 " 2 4'-0" 2 4'-0" 4 3'-5" 2 10'-11" 4.5 KIPS HDU8 HDU8 HDU8 HDU8 STHD10 STHD10 STHD10 STHD14 HDU8 HDU8 HDU8 HDU8 ST H D 1 0 ST D H 1 0 HD U 8 HD U 8 HD U 8 HD U 8 HD U 8 HD U 8 ST H D 1 4 ST H D 1 4 ST H D 1 4 ST H D 1 4 ST H D 1 4 ST H D 1 4 P.T. BY OTHERS 9 SD-1 TYP. 10 SD-1 TYP. NO STRUCTURAL CHANGES HD U 8 HD U 8 17.0 KIPS 17.0 KIPS 7. 5 K I P S 7. 5 K I P S 12" THICK (24" BLW GRADE) FOOTING W/ #4 AT 12" O.C. EA. WAY 6" TYP. 6" TYP. 10 SD-1TYP. FO U N D A T I O N P L A N - P L A N 1 A S1-1.0 SHEET NO. PROJECT NO. FIRST SUBMITTAL DATE STAMP MO R E N G I N E E R S I N C . 2 0 2 1 . T H E S E D R A W I N G S A N D T H E A C C O M P A N Y I N G C A L C U L A T I O N S A R E T H E E X C L U S I V E P R O P E R T Y O F M O R E N G I N E E R S I N C . A N D M A Y N O T B E R E P R O D U C E D I N A N Y F O R M W I T H O U T W R I T T E N P E R M I S S I O N F R O M T H E E N G I N E E R PL O T D A T E : 03 - 3 0 - 2 0 2 3 PO I N T H A P P Y SI N G L E F A M I L Y D E T A C H E D LA Q U I N T A , C A 2151 1401 DOVE STREET, SUITE 520 NEWPORT BEACH, CA 92660 PH: (949) 502-5323 FOUNDATION PLAN NOTES, POST-TENSIONED 1.REFER TO SHEETS SN AND SD-1 FOR TYPICAL NOTES AND DETAILS. 2.FIELD VERIFY ALL DIMENSIONS PRIOR TO START OF WORK. VERIFY DIMENSIONS WITH ARCHITECTURAL PLANS AND WITH EXISTING CONDITIONS PRIOR TO THE START OF ANY CONSTRUCTION. CONTRACTOR SHALL VERIFY TENDON LENGTHS AND STRESSING TAIL LENGTHS PRIOR TO FABRICATING CABLES. NOTIFY THE ARCHITECT AND ENGINEER-OF-RECORD FOR ANY DISCREPANCIES. 3.ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS SHALL BE SECURED WITH 5/8" DIAMETER ANCHOR BOLTS WITH A MAXIMUM SPACING OF 72" O.C. REFER TO FOUNDATION PLAN FOR ANCHOR BOLT SIZE AND SPACING AT SHEAR WALLS. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIECE OF FOUNDATION PLATE 12" OR LONGER WITH ONE BOLT LOCATED NOT MORE THAN 12" AND NOT LESS THAN 8" OF EACH END OF EACH PIECE. ANCHOR BOLTS SHALL BE GALVANIZED IF SET CORROSIVE PRESERVATIVE TREATED LUMBER. ANCHOR BOLTS MAY BE WET SET DURING PLACEMENT OF CONCRETE. REFER TO DETAIL 5/SD-1 FOR ADDITIONAL REQUIREMENTS. 4.ALL INTERIOR NON-BEARING AND NON-SHEAR WALLS AND PARTITIONS WHERE ANCHOR BOLTS ARE NOT NOTED ARE TO BE SECURED WITH SHOT PINS U.N.O. SHOT PINS SHALL BE 0.145" DIA. X 2.875" SHANK LENGTH WITH METAL PLATE WASHER AT 36 INCHES OC. THERE SHALL BE A MINIMUM OF TWO FASTENERS PER PIECE OF FOUNDATION PLATE 16" OR LONGER WITH ONE FASTENER LOCATED 6" FROM EACH END OF EACH PIECE. 5.ALL HOLD DOWNS AND EMBEDDED STRAPS SHALL BE INSTALLED PER DETAILS 9/SD-1 AND 10/SD-1. REFER TO FRAMING PLANS FOR LOCATIONS OF HARDWARE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THEIR EXACT LOCATION. 6.INSTALL ALL FOUNDATION HARDWARE PER THE MANUFACTURERS RECOMMENDATIONS. DEEPEN FOOTING WHERE NECESSARY TO PROVIDE ANCHOR EMBEDMENT AT HOLD DOWN LOCATIONS. ALL FOUNDATION HARDWARE (EXCEPT WET SET ANCHOR BOLTS) SHALL BE SECURED AND TIED IN PLACE PRIOR TO FOOTING INSPECTION AND PLACEMENT OF CONCRETE. 7.REFER TO DETAIL 1/SD-1 FOR CONVENTIONAL REINFORCING BAR, STIRRUP AND TIE BENDS. 8.REFER TO DETAIL 2/SD-1 FOR LAPPING OF CONVENTIONAL REINFORCING. 9.REFER TO DETAIL 3/SD-1 FOR TRENCHES ADJACENT TO FOUNDATIONS. 10.REFER TO THE SOILS REPORT(S) FOR ANY PAD PREPARATION AND PRE SATURATION REQUIREMENTS. 11.THE FLOOR SLAB SHALL BE POURED LEVEL TO WITHIN 1/8 INCH IN 10 FEET. 12.THE FLOOR SLAB AND FOUNDATION SHALL BE POURED MONOLITHICALLY (AT THE SAME TIME). 13.THE STRESSING END AND DEAD END OF THE TENDONS MAY BE REVERSED FROM THAT SHOWN ON THE PLANS. REFER TO DETAIL 4/SD-1 FOR ADDITIONAL ANCHORAGE INFORMATION. 14.TENDONS AND CONVENTIONAL REINFORCEMENT SHALL BE CHAIRED AND TIED IN PLACE PRIOR TO THE PLACEMENT OF CONCRETE. 15.FLAT WORK (PATIOS, STOOPS, PORCHES, DRIVEWAYS AND SIMILAR FEATURES) MAY BE DOWELED TO THIS FOUNDATION WITH #3 DOWELS X 3 FEET LONG AT 2 FEET ON CENTER. DOWELS SHOULD EXTEND AT LEAST 1 FOOT 4 INCHES INTO EACH POUR. IT IS NOT THE INTENT OF THESE DRAWINGS TO SPECIFY FLAT WORK. 16.SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION. 17.SLABS SHALL BE PERMANENTLY MARKED INSIDE THE GARAGE DOOR AREA AS FOLLOWS: POST TENSION SLAB IN THIS BUILDING DRILLING OR CUTTING INTO THE ENCASED CABLE TENDONS INSTALLED WITHIN THE CONCRETE SLAB WITHOUT SUCCULENT DESIGN COULD DAMAGED THE STRUCTURAL INTEGRITY OF THE BUILDING. DO NOT REMOVE OR DAMAGE ANY FLOOR ELEMENT BEFORE CONSULTING A QUALIFIED ENGINEER OR YOUR BUILDING DEPARTMENT. INDICATES STRAP/HOLDOWN TO BE INSTALLED ON SIDE OF POST AS SHOWN FOUNDATION LEGEND PLAN CHECK & CLIENT REV.05/02/2022 CLIENT REV.03/30/2023 10/30/2024Edward Ghera BWFE2024-0279 WILLIAMS HOMES / 130 LF OF 6 FOOT HIGH GARDEN WALLS AT WEST P/L WITH RETURNS AND 2 PILASTERS AT ENTRY [PROTO II SPECIFICATIONS]. PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2022 CALIFORNIA BUILDING CODES. FOUNDATION PLAN 1B SCALE: 1/4"=1'-0" (SEE PLAN 1A FOR MORE INFORMATION) BDRM. 2 BA. 2 BDRM. 3 BA. 3 FLEX RM. W.I.C. P. BATH HALL P. BDRM. OUTDOOR RM. SERVICE KITCHEN DINING GREAT RM. FOYER PWDR. P. D.Z. 2-BAY GARAGE 1-BAY GARAGE CVRD. ENTRY S L O P E 4:1 2 6 7'-1" 6 7'-1" P.T. BY OTHERS S T H D 1 4 ST H D 1 4 ST H D 1 4 ST H D 1 4 FO U N D A T I O N P L A N - P L A N 1 B S1-1.1 SHEET NO. PROJECT NO. FIRST SUBMITTAL DATE STAMP MO R E N G I N E E R S I N C . 2 0 2 1 . T H E S E D R A W I N G S A N D T H E A C C O M P A N Y I N G C A L C U L A T I O N S A R E T H E E X C L U S I V E P R O P E R T Y O F M O R E N G I N E E R S I N C . A N D M A Y N O T B E R E P R O D U C E D I N A N Y F O R M W I T H O U T W R I T T E N P E R M I S S I O N F R O M T H E E N G I N E E R PL O T D A T E : 04 - 0 5 - 2 0 2 3 PO I N T H A P P Y SI N G L E F A M I L Y D E T A C H E D LA Q U I N T A , C A 2151 1401 DOVE STREET, SUITE 520 NEWPORT BEACH, CA 92660 PH: (949) 502-5323 FOUNDATION PLAN NOTES, POST-TENSIONED 1.REFER TO SHEETS SN AND SD-1 FOR TYPICAL NOTES AND DETAILS. 2.FIELD VERIFY ALL DIMENSIONS PRIOR TO START OF WORK. VERIFY DIMENSIONS WITH ARCHITECTURAL PLANS AND WITH EXISTING CONDITIONS PRIOR TO THE START OF ANY CONSTRUCTION. CONTRACTOR SHALL VERIFY TENDON LENGTHS AND STRESSING TAIL LENGTHS PRIOR TO FABRICATING CABLES. NOTIFY THE ARCHITECT AND ENGINEER-OF-RECORD FOR ANY DISCREPANCIES. 3.ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS SHALL BE SECURED WITH 5/8" DIAMETER ANCHOR BOLTS WITH A MAXIMUM SPACING OF 72" O.C. REFER TO FOUNDATION PLAN FOR ANCHOR BOLT SIZE AND SPACING AT SHEAR WALLS. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIECE OF FOUNDATION PLATE 12" OR LONGER WITH ONE BOLT LOCATED NOT MORE THAN 12" AND NOT LESS THAN 8" OF EACH END OF EACH PIECE. ANCHOR BOLTS SHALL BE GALVANIZED IF SET CORROSIVE PRESERVATIVE TREATED LUMBER. ANCHOR BOLTS MAY BE WET SET DURING PLACEMENT OF CONCRETE. REFER TO DETAIL 5/SD-1 FOR ADDITIONAL REQUIREMENTS. 4.ALL INTERIOR NON-BEARING AND NON-SHEAR WALLS AND PARTITIONS WHERE ANCHOR BOLTS ARE NOT NOTED ARE TO BE SECURED WITH SHOT PINS U.N.O. SHOT PINS SHALL BE 0.145" DIA. X 2.875" SHANK LENGTH WITH METAL PLATE WASHER AT 36 INCHES OC. THERE SHALL BE A MINIMUM OF TWO FASTENERS PER PIECE OF FOUNDATION PLATE 16" OR LONGER WITH ONE FASTENER LOCATED 6" FROM EACH END OF EACH PIECE. 5.ALL HOLD DOWNS AND EMBEDDED STRAPS SHALL BE INSTALLED PER DETAILS 9/SD-1 AND 10/SD-1. REFER TO FRAMING PLANS FOR LOCATIONS OF HARDWARE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THEIR EXACT LOCATION. 6.INSTALL ALL FOUNDATION HARDWARE PER THE MANUFACTURERS RECOMMENDATIONS. DEEPEN FOOTING WHERE NECESSARY TO PROVIDE ANCHOR EMBEDMENT AT HOLD DOWN LOCATIONS. ALL FOUNDATION HARDWARE (EXCEPT WET SET ANCHOR BOLTS) SHALL BE SECURED AND TIED IN PLACE PRIOR TO FOOTING INSPECTION AND PLACEMENT OF CONCRETE. 7.REFER TO DETAIL 1/SD-1 FOR CONVENTIONAL REINFORCING BAR, STIRRUP AND TIE BENDS. 8.REFER TO DETAIL 2/SD-1 FOR LAPPING OF CONVENTIONAL REINFORCING. 9.REFER TO DETAIL 3/SD-1 FOR TRENCHES ADJACENT TO FOUNDATIONS. 10.REFER TO THE SOILS REPORT(S) FOR ANY PAD PREPARATION AND PRE SATURATION REQUIREMENTS. 11.THE FLOOR SLAB SHALL BE POURED LEVEL TO WITHIN 1/8 INCH IN 10 FEET. 12.THE FLOOR SLAB AND FOUNDATION SHALL BE POURED MONOLITHICALLY (AT THE SAME TIME). 13.THE STRESSING END AND DEAD END OF THE TENDONS MAY BE REVERSED FROM THAT SHOWN ON THE PLANS. REFER TO DETAIL 4/SD-1 FOR ADDITIONAL ANCHORAGE INFORMATION. 14.TENDONS AND CONVENTIONAL REINFORCEMENT SHALL BE CHAIRED AND TIED IN PLACE PRIOR TO THE PLACEMENT OF CONCRETE. 15.FLAT WORK (PATIOS, STOOPS, PORCHES, DRIVEWAYS AND SIMILAR FEATURES) MAY BE DOWELED TO THIS FOUNDATION WITH #3 DOWELS X 3 FEET LONG AT 2 FEET ON CENTER. DOWELS SHOULD EXTEND AT LEAST 1 FOOT 4 INCHES INTO EACH POUR. IT IS NOT THE INTENT OF THESE DRAWINGS TO SPECIFY FLAT WORK. 16.SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION. 17.SLABS SHALL BE PERMANENTLY MARKED INSIDE THE GARAGE DOOR AREA AS FOLLOWS: POST TENSION SLAB IN THIS BUILDING DRILLING OR CUTTING INTO THE ENCASED CABLE TENDONS INSTALLED WITHIN THE CONCRETE SLAB WITHOUT SUCCULENT DESIGN COULD DAMAGED THE STRUCTURAL INTEGRITY OF THE BUILDING. DO NOT REMOVE OR DAMAGE ANY FLOOR ELEMENT BEFORE CONSULTING A QUALIFIED ENGINEER OR YOUR BUILDING DEPARTMENT. INDICATES STRAP/HOLDOWN TO BE INSTALLED ON SIDE OF POST AS SHOWN FOUNDATION LEGEND PLAN CHECK & CLIENT REV.05/02/2022 2- - 3 -1 20 5 A 9 HOOK BAR AT FOOTING INTERSECTION INTERSECTIONS HOOK BAR AT ENDS AT ENDS HOOK BAR INTERSECTIONS HOOK BAR AT CORNER, SINGLE BAR INTERSECTION, SINGLE BAR CORNER, DOUBLE BAR INTERSECTION, DOUBLE BAR REINF. PER PLAN HOOK BARS TO FAR SIDE OF FOOTING REINF. PER PLAN HOOK BARS TO FAR SIDE OF FOOTING BAR SIZE CONCRETE LAP LENGTH MASONRY LAP LENGTH #4 #5 #6 #7 #8 19" 29" 41" 54" 74" 21" 39" 47" 68" 78" 18 GRADING FOOTING 10'-0" MIN. 12 " 10'-0" TRENCH 12 " 2 1 GRADE 2 1 TRENCH 3'-0" IMAGINARY POINT OF REFERENCE (1'-0" ABOVE) BOTTOM OF EXCAVATION CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE SIDE OF ALL TRENCHES AND EXCAVATIONS FROM CAVING IN UNTIL ALL BACKFILLING IS COMPLETE. BACKFILL AS REQ'D BY SOILS REPORT OR CIVIL ENGINEER'S DRAWINGS. MAINTAIN SOIL AT SIDE OF FOOTING BOTTOM OF TRENCH OR EXCAVATION SHALL NOT EXTEND BELOW THIS LINE WHERE UTILITIES PASS BELOW PERIMETER FOUNDATION BACK FILL WITH NATIVE SOIL OR CONCRETE FROM FOUNDATION POUR TRENCHING FOUNDATION SLOPING GRADE POINT OF DAYLIGHT IMAGINARY POINT OF REFERENCE (1'-0" ABOVE BOTTOM OF EXCAVATION) FOOTING SETBACK TO SLOPE CAUTION: NOTE: CONTRACTOR RESPONSIBLE FOR PREVENTING TRENCH FROM CAVING IN. HOLD DOWN ALL-THREAD RODS BAR BENDS STANDARD HOOKS 90° BEND 180° BEND STIRRUP AND TIE HOOKS BAR SIZE MIN. DIAMETER (D) NO. 3 THROUGH NO. 8 6d 8d 10d - D 4d OR 2-1/2" MIN D D D 12d 45° BEND NO. 14 AND NO. 18 NO. 9, NO. 10, AND NO. 11 90° BEND D 6d AT NO. 5 AND SMALLER 12d AT NO. 6, 7, AND 8 135° BEND D 6d AT NO. 8 AND SMALLER "d " "d" "d" "d " LAP LENGTH 1" C L R . 6 1 TYP. LAP SPLICE CONCRETE EMBEDMENT WITH HOOKSTRAIGHT BAR 12" 13" 16" 18" 21" 12" 18" 24" 33" 43" CONT. CONC. FTG. OR WALL CONT. CONC. FTG. OR WALL ANCHOR BOLT ONE POUR NOTE: 1.SB/SSTB BOLT IS TO BE INSTALLED AT A 45° ANGLE TO THE DIRECTION OF THE FOUNDATION 2.USE SSTBL FOR HDU HOLD DOWNS TO BE INSTALLED ON 2-2X OR 3X SILL PLATE 3.PRIOR TO WRAPPING STRUCTURE, HOLDOWNS SHALL BE FINGER-TIGHT AND 1/2 WRENCH TURN. 4.FOR HD19, SEE DETAIL 5/SD-1 FOR PLATE WASHER FOR CONNECTION TO WOOD FRAMING. SB/ SSTB BOLT PLACEMENT PAB BOLT PLACEMENT 2'-6" MIN 4'-0" AT 1" OR LARGER RODS #4 BAR AND AT FIELD #4 BAR AT CORNER AT EDGE SSTB/SB BOLT Le @ EXT. 3" CL R . COLD JOINT CONCRETE FOOTING AND REINFORCING PER SCHEDULE (1) #4 BAR REQUIRED CENTERED ON BOLT (MAY BE FOUNDATION REINFORCEMENT) MIN. EDGE DIST. 5'-0" MIN 8'-0" AT 1" OR LARGER RODS DEEPEN FOOTING PAST CENTER LINE OF BOLT 12" MIN. (15" MIN. AT 1" OR LARGER BOLT) WITH SLOPE2 1 SIMPSON FASTENERS HOLD DOWN TO POST PER MFR. POST PER PLAN W/ E.N. MIN. EDGE DISTANCE MIN. EMBED. le LENGTHBOLT DIA.BOLT HOLDOWN HDU8 HDU5 HTT5 5/8" 5/8" 7/8"1-3/4" 1-3/4" 1-3/4"SSTB24 25"20" SSTB24 25"20" SSTB34 35"28" HDU11 HDU14 1" 1" 1-3/4" 2-3/4" SB1X30 SB1X30 30" 30" 24" 24" HD19 1-1/4"2-3/4"PAB10 N/A 15" AT EXT. CONDITION 6" 8" MI N . MI N . 44" MIN. 3" MI N . Le A T I N T . F O O T I N G & C U R B C O N D I T I O N Le EX T . F O O T I N G CURB WHERE APPLICABLE NOTE: 1.EXTEND FOOTING 22" MIN. ON EACH SIDE OF BOLT SIMPSON FASTENERS HOLD DOWN TO POST PER MFR. POST PER PLAN W/ E.N. - AT INTERIOR FT'G CONDITION @ INT. CONDITION 10" LONG ANCHOR BOLTS AT 2X PLATES AND 12" LONG ANCHOR BOLTS AT 3X PLATES SILL PLATE PER PLAN USE SIMPSON TITEN HD CONCRETE SCREW ANCHOR FOR OMITTED ANCHOR BOLTS. USE 1/2" DIA. OR 5/8" DIA. X 6" TITEN HD TO SUBSTITUTE FOR 1/2" DIA. OR 5/8" DIA. A.B. RESPECTIVELY AT 2X SILL SQUARE PLATE WASHERS FOUNDATION HOOK: BOLT LENGTH MINIMUM 2" FULL THREADS SHALL EXTEND ABOVE TOP OF NUT ALL-THREAD ROD ASTM F1554 / 307 MIN. W/ ADHESIVE BOLT SIZE MIN. EMBED, le 1/2" 5/8" 3/4" 7/8" 1" 5" 6" 7" 8" 9" ALL-THREAD SCREW IN CAST IN ANCHOR BOLT SIZE MINIMUM END DISTANCE MIN. EDGE DISTANCE MINIMUM PLATE SIZE MINIMUM DISTANCE BETWEEN BOLTS SQUARE PLATE WASHER SIZE BORING THRU PLATETO CONC.TO WOOD SIDE ID THICKNESS 1/2" 5/8" 3/4" 7/8" 1" 1"-2" 2"-2-1/2" 2"-2-1/2" 3" 3-1/2" 1/2" 5/8" 3/4" 7/8" 1" 3-1/2" 4-3/8" 5-1/4" 6-1/8" 7" 1-3/4" 1-3/4" 1-3/4" 2-1/2" 2-1/2" 3/4" 1" 1-1/8" 1-3/8" 1-1/2" 2x4 2x4 2x4 2x6 2x6 3" 3" 3" 4" 4" 3" 3" 3" 3" 3-1/2" 9/16" 11/16" 13/16" 15/16" 1-1/16" 0.229" 5/16" 5/16" 3/8" 9/16" 11/16" 13/16" 5/16" 1-1/16" (POST-POUR) HEX WASHER HEAD (ADDITIONAL WASHER REQ'D PER TABLE BELOW) DIAGONAL SLOT W 11/16" 13/16" 15/16" 17/16" 19/16" SQUARE PLATE WASHER W/ DIAGONAL SLOT, STANDARD CUT WASHER REQUIRED WITH DIAGONAL SLOT 1-3 / 4 " MA X . W ROUND SLOT 4 5 ° (POST-POUR) 7" M I N EM B E D EDGE DISTANCE MIN. EDGE DISTANCE TO WOOD MIN. DIST. BETWEEN BOLTS MI N . E D G E DI S T A N C E TO W O O D SILL PLATE SQUARE PLATE WASHER PLAN VIEW 0.229" PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE OF THE SHEATHED SIDE. 1. - --10--- - - - - -SCOOP FOOTING STUD WALL ANCHOR BOLT (ALT. HOLDOWN BOLT) DEEPEN FOOTING TO PROVIDE SUFFICIENT CONCRETE COVER FOR ANCHOR BOLTS (3") AND FOR HOLDOWN BOLTS PER DETAIL 9/SD-1 PER PTPER PT Floor slab. Place slab reinforcement above center line and below upper 1/3 of slab thickness. Reinforcement shall be chaired and tied in place prior to placement of concrete. Sand shall be dampened prior to placement of concrete. Slab and sand thickness' given are actual not nominal Note: 1.Saturate the soil 18-in. deep before placing the concrete slab. 2.Vapor Barrier & lower base layer may be omitted at non-conditioned areas such as garages. Thickness Floor Slab Lower base Barrier Floor Slab Reinforcement layer Upper base layer Vapor "T" PER PT INDEX EXPANSION "I" FOUNDATION SCHEDULE PER PT PER PTPER PT 3" CLR3"CL R 7' - 6 " M A X . PE R L A N D S C A P E 6" M I N . 12 " M A X . 12 " 2" CLR MIN. CAUTION: THIS WALL IS NOT DESIGNED FOR PLACEMENT ADJACENT TO A SLOPE BUT FOR GRADED BEING LEVEL ON BOTH SIDES OF THE FOOTING #4 TIES AT 16" O.C. (TYP) GROUT SOLID (NO SPECIAL INSP. REQ'D) (1) #5 VERT. BARS PER CORNER (TYP) ALTERNATE DIRECTION FINISH PER LANDSCAPE OF BLOCKS TYP. DRAWINGS #4 VERT. BARS AT EA. 6"X6"X16" CONCRETE BLOCK. GROUT SOLID (SPECIAL INSP. IS NOT REQ'D) EMBED FIRST CONCRETE BLOCK 2" INTO FND POUR (4) #5 BARS EA. WAY POURED CONCRETE FT'G 3" CLR PILASTER TYPICAL PILASTER 2" C L R CORNER (4) TOTAL #4 BAR TIES AT 24" O.C. BLOCK. GROUT SOLID FINAL SURFACE AT LANDSCAPE LEVEL COMPACTED GRADE PER PLAN 6" EQ. 6" REFERENCE: 35/L1.4 LANDSCAPE STONE CAP BY OTHERS VENEER BY OTHERS 36" MAX. IF APPLICABLE ENTRY PILASTER 2 PER LANDSCAPE ARCH. PE R L A N D S C A P E AR C H . FO U N D A T I O N D E T A I L S SD-1 SHEET NO. PROJECT NO. FIRST SUBMITTAL DATE STAMP MO R E N G I N E E R S I N C . 2 0 2 1 . T H E S E D R A W I N G S A N D T H E A C C O M P A N Y I N G C A L C U L A T I O N S A R E T H E E X C L U S I V E P R O P E R T Y O F M O R E N G I N E E R S I N C . A N D M A Y N O T B E R E P R O D U C E D I N A N Y F O R M W I T H O U T W R I T T E N P E R M I S S I O N F R O M T H E E N G I N E E R PL O T D A T E : 04 - 0 5 - 2 0 2 3 PO I N T H A P P Y SI N G L E F A M I L Y D E T A C H E D LA Q U I N T A , C A 2151 1401 DOVE STREET, SUITE 520 NEWPORT BEACH, CA 92660 PH: (949) 502-5323 2 CLIENT REV.03/30/2023 LC-01 7 CO N S T R U C T I O N D E T A I L S SCALE: SEE SHEET 09/30/24 EXP. DATE SIGNATURE LLA 5508 O INR I L I EPCN C A C INOLM O 01/19/2023 WI L L I A M S H O M E S CI T Y O F L A Q U I N T A TR 3 1 3 4 8 - P O I N T H A P P Y PR O D U C T I O N F R O N T Y A R D S 28 9 2 4 O L D T O W N F R O N T S T R E E T , S U I T E 2 0 2 TE M E C U L A , C A 9 2 5 9 0 P ( 8 4 4 ) W E I L A N D , X T 7 0 1 F ( 6 1 9 ) 6 7 5 - 3 4 2 6 EM A I L - K L O N I G R O @ W - D - G . C O M CO R P O R A T E O F F I C E 29 1 S I E R R A W A V E S W A L L M E A D O W S , C A 9 3 5 1 4 DATE: 01/19/2023 JOB # 22-032f DRAWN: KTL, MD 10/04/2022, 10/2/2022, 12/14/2022, 01/19/2023 OLAC E SED L I S T E T R SHEET: OF 8 RE V I S I O N S DA T E DATE A FF E T A T S A C N H AD R IK GT. WE I L A N D D E S I G N G R O U P , I N C . LA N D S C A P E A R C H I T E C T U R E + P L A N N I N G + C O N S T R U C T I O N M A N A G E M E N T 2 2 - 1 4 1 4 8 B AC 6 3 -2"4 2 -6" N.T.S.PLAN 1A ENTRY GATE ELEVATION 1 2 3 DECORATIVE CMU BLOC. ENTRY WALLS WITH STUCCO FINISH TO MATCH ARCHITECTURE, COLOR TO MATCH LOWER STUCCO COLOR ON HOME DECORATIVE METAL GATE WITH FROSTED WINDOW PANELS, GATE PER SEPARATE SHOP DRAWINGS BY OTHERS, COLOR PER ARCHITECTURE COLOR BOARD FINISH GRADE / FINISH SURFACE PER PRECISE GRADING PLANS - TYP. LEGEND 3 -3"2 -6"4 2 ELEVATION PLAN 4 2" S4. TUBULAR STEEL GATE POSTS 5 AD-ACENT HOUSE WALLS 1 2 3 4 5 1 2 1POP-OUT AT GARAGE 5 - 1 0 " 2" 2" 6 3 -2"4 2 -6" N.T.S.PLAN 1B ENTRY GATE ELEVATION 1 2 3 DECORATIVE CMU BLOC. ENTRY WALLS WITH STUCCO FINISH TO MATCH ARCHITECTURE, COLOR TO MATCH LOWER STUCCO COLOR ON HOME DECORATIVE METAL GATE WITH FROSTED WINDOW PANELS, GATE PER SEPARATE SHOP DRAWINGS BY OTHERS, COLOR PER ARCHITECTURE COLOR BOARD FINISH GRADE / FINISH SURFACE PER PRECISE GRADING PLANS - TYP. LEGEND 3 -3"2 -6"4 2 ELEVATION PLAN 5 - 1 0 " 2" 4 TUBULAR STEEL GATE POSTS 5 AD-ACENT HOUSE WALLS 1 2 3 4 5 1 2 1POP-OUT AT GARAGE 2" 1 2 3 4 5 6 2 3 8 24" S4. 4 6 6 6" MI N . 6 H T . ROUNDED MORTAR CAP WITH STUCCO FINISH TO MATCH ARCHITECTURE STUCCO FINISH TO MATCH ARCHITECTURE - ALL VISIBLE SURFACES CMU BLOC. PILASTER - REINFORCEMENT FOOTING PER STRUCTURAL DETAILS STUCCO SCREED - REFER TO SEPARATE DETAIL FINISH GRADE PER CIVIL ENGINEER 90 COMPACTED SUBGRADE OR PER SOILS REPORT RECOMMENDATIONS 2" TY P . NOTES: 1. ALL FINISH GRADES AND SURFACES SHALL SLOPE AT 2 AWAY FROM WALLS PILASTERS 2. REINFORCING RE4UIREMENTS, FOOTING SIZES, AND SUBGRADE COMPACTION PER CITY STANDARD DETAILS STRUCTURAL / CIVIL ENGINEERING DRAWINGS AND REPORTS. CONTRACTOR TO VERIFY REINFORCING, FTG. SIZES SUBGRADE COMPACTION RE4UIREMENTS PRIOR TO CONSTRUCTION. 3/4"=1'-0"24" STUCCO ENTRY WALL AT PLAN 1 LEGEND 1" 1 01/12/2023J.ANAYA 01/12/2023J.ANAYA