Loading...
Rancho Santana TR 31202 (PSN 05610) Plans 1, 3, 7 & 7X Master Solar 2019 Code Cycle Revision 2DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA 81-769 Avenue 52 LA QUINTA, CA M I VICINITY MAP SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER PV COVER AC PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 3 DATE: 7/20/2022 P JA SOLAR JAM60S17-320/MR OR JA SOLAR JAM60S17-325/MR MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE RE V I S I O N S RE V DE S C R I P T I O N DA T E 1 1S T R E V I E W 9/ 4 / 2 0 2 0 SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 2.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV EE 2.0 ELECTRICAL CONT. PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH RANCHO SANTANA 3.1.PLAN: 3 3.2.ELEVATIONS: A, B 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: SOLAREDGE SE7600H 5.2.RANCHO SANTANA TO UTILIZE ONE OF THE FOLLOWING SOLAR MODULE TYPES: 5.2.1.JA SOLAR JAM60S17-320/MR 5.2.2.JA SOLAR JAM60S17-325/MR 5.3.RANCHO SANTANA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.20 MODULES 6.40kW DC / 5.869kW AC FOR JA SOLAR JAM60S17-320/MR 5.3.2.20 MODULES 6.50 kW DC / 5.962kW AC FOR JA SOLAR JAM60S17-325/MR 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. REVISION #2 BCPR2020-0010 ADD EXTERIOR AC DISCONNECT FOR ALL PLAN TYPES 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 3 DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 3 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" ELEVATION: A SCALE: 1/16" = 1'-0" ELEVATION: A SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE PV STRING(S): #1) 10 MODULES #2)10 MODULES OPTION(S): NONE OPTION(S): NONE OPTION(S): NONEOPTION(S): NONEOPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT ELEVATION: A ELEVATION: A ELEVATION: A SYSTEM SIZE: 20 MODULES AT 6.400 kW DC OR 20 MODULES AT 6.500 kW DC 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 3 DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 3 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. GARAGE: LEFT SCALE: 1/16" = 1'-0" ELEVATION: B GARAGE: RIGHT SCALE: 1/16" = 1'-0" ELEVATION: B SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" ELEVATION: B SCALE: 1/16" = 1'-0" OPTION(S): NONE PV STRING(S): #1) 10 MODULES #2)10 MODULES OPTION(S): NONE OPTION(S): NONE OPTION(S): NONEOPTION(S): NONEOPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT ELEVATION: B ELEVATION: B ELEVATION: B SYSTEM SIZE: 20 MODULES AT 6.400 kW DC OR 20 MODULES AT 6.500 kW DC 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 3 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 3 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA 81-769 Avenue 52 LA QUINTA, CA M I VICINITY MAP SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER PV COVER AC PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 P JA SOLAR JAM60S17-320/MR OR JA SOLAR JAM60S17-325/MR MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE RE V I S I O N S RE V DE S C R I P T I O N DA T E 1 1S T R E V I E W 9/ 4 / 2 0 2 0 GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH RANCHO SANTANA 3.1.PLAN: 7 3.2.ELEVATIONS: A, B 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: SOLAREDGE SE7600H 5.2.RANCHO SANTANA TO UTILIZE ONE OF THE FOLLOWING SOLAR MODULE TYPES: 5.2.1.JA SOLAR JAM60S17-320/MR 5.2.2.JA SOLAR JAM60S17-325/MR 5.3.RANCHO SANTANA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.22 MODULES 7.04kW DC / 6.456kW AC FOR JA SOLAR JAM60S17-320/MR 5.3.2.22 MODULES 7.04 kW DC / 6.558kW AC FOR JA SOLAR JAM60S17-325/MR 5.3.3.30 MODULES 9.60kW DC / 8.803kW AC FOR JA SOLAR JAM60S17-320/MR 5.3.4.30 MODULES 9.60 kW DC / 8.943kW AC FOR JA SOLAR JAM60S17-325/MR 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 2.0 PV LAYOUTS CONT. PV RL 3.0 PV LAYOUTS CONT. PV RL 4.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV EE 2.0 ELECTRICAL CONT. PV EE 3.0 ELECTRICAL CONT. PV EE 4.0 ELECTRICAL CONT. PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 22 MODULES AT 7.040 kW DC OR 22 MODULES AT 7.150 kW DC 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 LAYOUT 13 LAYOUT 14 LAYOUT 15 LAYOUT 16 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 30 MODULES AT 9.600 kW DC OR 30 MODULES AT 9.750 kW DC 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 3.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC 22 MODULES AT 7.040 kW DC ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 22 MODULES AT 7.040 kW DC OR 22 MODULES AT 7.150 kW DC 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 4.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 LAYOUT 13 LAYOUT 14 LAYOUT 15 LAYOUT 16 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 30 MODULES AT 9.600 kW DC OR 30 MODULES AT 9.750 kW DC 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 3.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 4.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA 81-769 Avenue 52 LA QUINTA, CA M I VICINITY MAP SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER PV COVER AC PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 P JA SOLAR JAM60S17-320/MR OR JA SOLAR JAM60S17-325/MR MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE RE V I S I O N S RE V DE S C R I P T I O N DA T E 1 1S T R E V I E W 9/ 4 / 2 0 2 0 GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH RANCHO SANTANA 3.1.PLAN: 7X 3.2.ELEVATIONS: A, B 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: SOLAREDGE SE7600H 5.2.RANCHO SANTANA TO UTILIZE ONE OF THE FOLLOWING SOLAR MODULE TYPES: 5.2.1.JA SOLAR JAM60S17-320/MR 5.2.2.JA SOLAR JAM60S17-325/MR 5.3.RANCHO SANTANA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.22 MODULES 7.04kW DC / 6.456kW AC FOR JA SOLAR JAM60S17-320/MR 5.3.2.22 MODULES 7.04 kW DC / 6.558kW AC FOR JA SOLAR JAM60S17-325/MR 5.3.3.30 MODULES 9.60kW DC / 8.803kW AC FOR JA SOLAR JAM60S17-320/MR 5.3.4.30 MODULES 9.60 kW DC / 8.943kW AC FOR JA SOLAR JAM60S17-325/MR 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 2.0 PV LAYOUTS CONT. PV RL 3.0 PV LAYOUTS CONT. PV RL 4.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV EE 2.0 ELECTRICAL CONT. PV EE 3.0 ELECTRICAL CONT. PV EE 4.0 ELECTRICAL CONT. PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. 08/31/2022 IMAC AC I MAC AC I MAC AC IMAC AC I MAC AC IMAC AC I MAC AC IMAC AC PV RL 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7X FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 22 MODULES AT 7.040 kW DC OR 22 MODULES AT 7.150 kW DC 08/31/2022 IMAC AC I MAC AC I MAC AC IMAC AC I MAC AC IMAC AC I MAC AC IMAC AC PV RL 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 LAYOUT 13 LAYOUT 14 LAYOUT 15 LAYOUT 16 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7X FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION ELEVATION: A OPTION(S): CASITA ADDITION GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 30 MODULES AT 9.600 kW DC OR 30 MODULES AT 9.750 kW DC 08/31/2022 IMAC AC I MAC AC I MAC AC IMAC AC I MAC AC IMAC AC I MAC AC IMAC AC PV RL 3.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7X FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 22 MODULES AT 7.040 kW DC OR 22 MODULES AT 7.150 kW DC 08/31/2022 IMAC AC I MAC AC I MAC AC IMAC AC I MAC AC IMAC AC I MAC AC IMAC AC PV RL 4.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12 LAYOUT 13 LAYOUT 14 LAYOUT 15 LAYOUT 16 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 7X FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION ELEVATION: B OPTION(S): CASITA ADDITION GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 30 MODULES AT 9.600 kW DC OR 30 MODULES AT 9.750 kW DC 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 3.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 4.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 7X DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA 81-769 Avenue 52 LA QUINTA, CA M I VICINITY MAP SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE UTILITY PRODUCTION METER PV COVER AC PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 2 DATE: 7/20/2022 P JA SOLAR JAM60S17-320/MR OR JA SOLAR JAM60S17-325/MR MODULES. SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE RE V I S I O N S RE V DE S C R I P T I O N DA T E 1 1S T R E V I E W 9/ 4 / 2 0 2 0 SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 2.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV EE 2.0 ELECTRICAL CONT. PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH RANCHO SANTANA 3.1.PLAN: 2 3.2.ELEVATIONS: A, B 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: SOLAREDGE SE7600H 5.2.RANCHO SANTANA TO UTILIZE ONE OF THE FOLLOWING SOLAR MODULE TYPES: 5.2.1.JA SOLAR JAM60S17-320/MR 5.2.2.JA SOLAR JAM60S17-325/MR 5.3.RANCHO SANTANA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.18 MODULES 5.76kW DC / 5.282kW AC FOR JA SOLAR JAM60S17-320/MR 5.3.2.18 MODULES 5.85 kW DC / 5.366kW AC FOR JA SOLAR JAM60S17-325/MR 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 2 DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E 1 CO R R E C T E D M O D U L E C O U N T 7/ 8 / 2 0 2 1 AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 2 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE PV STRING(S): #1) 9 MODULES #2)9 MODULES ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT SYSTEM SIZE: 18 MODULES AT 5.760 kW DC OR 18 MODULES AT 5.850 kW DC 08/31/2022 I M ACAC I M AC AC I M AC AC I M ACAC I M AC AC I M ACAC I M AC AC I M ACAC PV RL 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 2 DATE: 7/20/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E 1 CO R R E C T E D M O D U L E C O U N T 7/ 8 / 2 0 2 1 AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) PV ROOF LAYOUTS PLAN 2 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" OPTION(S): NONE PV STRING(S): #1) 9 MODULES #2)9 MODULES OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONEOPTION(S): NONEOPTION(S): NONEOPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT ELEVATION: B ELEVATION: B ELEVATION: B ELEVATION: BELEVATION: BELEVATION: BELEVATION: B SYSTEM SIZE: 18 MODULES AT 5.760 kW DC OR 18 MODULES AT 5.850 kW DC 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 1.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 2 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 2.0 PV SYSTEM PROVIDED BY: vivint.Solar 1.877.404.4129 CA LICENSE: 750184 HOME DEVELOPER: DESERT ESTATES 78-401 HWY 111 SUITE X LA QUINTA, CA 92253 RANCHO SANTANA LA QUINTA, CA PLAN: 2 DATE: 7/20/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E AD D E D O U T S I D E A C D I S C O N N E C T P E R U T I L I T Y R E Q U I R E M E N T S ( 7 . 2 0 . 2 0 2 2 ) *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 08/31/2022