Rancho Santana TR 31202 (PSN 05608) Plan 7X & 7X with Casita Master Solar Revision 1DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
81-769 Avenue 52
LA QUINTA, CA
M
I
VICINITY MAP
SYMBOLS AND ABBREVIATIONS:
MAIN SERVICE PANEL AND POINT OF INTERCONNECTION
PV SYSTEM AC DISCONNECT TO BE INSTALLED INSIDE THE GARAGE
PV SYSTEM INVERTER TO BE INSTALLED INSIDE THE GARAGE
UTILITY PRODUCTION METER
PV COVER
AC
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
P
JA SOLAR JAM60S17-320/MR OR JA SOLAR JAM60S17-325/MR MODULES.
SOLAREDGE P370 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
1
1S
T
R
E
V
I
E
W
9/
4
/
2
0
2
0
GOVERNING CODES:
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
1.2019 CA BUILDING CODE
2.2019 CA ENERGY CODE
3.2019 CA ELECTRICAL CODE
4.2019 CA FIRE CODE
5.2019 CA GREEN CODE
6.2019 CA MECHANICAL CODE
7.2019 CA PLUMBING CODE
8.2019 CA RESIDENTIAL CODE
9.ANY OTHER LOCAL AMENDMENTS
GENERAL NOTES:
1.ELECTRICAL
1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR
SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF
THE ROOF SURFACE.
1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE.
1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN
COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE.
1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS.
2.STRUCTURAL
2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY
SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE
STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD.
2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2"
PENETRATION INTO ROOF FRAMING.
2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM.
2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.
2.5.GROUND SNOW LOAD = 0 psf
2.6.WIND SPEED = 130 mph
2.7.EXPOSURE CATEGORY = C
SCOPE OF WORK
3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH RANCHO SANTANA
3.1.PLAN: 7X
3.2.ELEVATIONS: A, B
4.BUILDING INFORMATION:
4.1.BUILDING OCCUPANCY GROUP: R3/U
4.2.CONSTRUCTION TYPE: VB
5.PV
5.1.INVERTER: SOLAREDGE SE7600H
5.2.RANCHO SANTANA TO UTILIZE ONE OF THE FOLLOWING SOLAR MODULE TYPES:
5.2.1.JA SOLAR JAM60S17-320/MR
5.2.2.JA SOLAR JAM60S17-325/MR
5.3.RANCHO SANTANA TO UTILIZE THE FOLLOWING SYSTEM SIZES:
5.3.1.22 MODULES 7.04kW DC / 6.456kW AC FOR JA SOLAR JAM60S17-320/MR
5.3.2.22 MODULES 7.04 kW DC / 6.558kW AC FOR JA SOLAR JAM60S17-325/MR
5.3.3.30 MODULES 9.60kW DC / 8.803kW AC FOR JA SOLAR JAM60S17-320/MR
5.3.4.30 MODULES 9.60 kW DC / 8.943kW AC FOR JA SOLAR JAM60S17-325/MR
5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV
EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT.
SHEET INDEX:
PV COVER COVER SHEET
PV RL 1.0 PV LAYOUTS
PV RL 2.0 PV LAYOUTS CONT.
PV RL 3.0 PV LAYOUTS CONT.
PV RL 4.0 PV LAYOUTS CONT.
PV EE 1.0 ELECTRICAL
PV EE 2.0 ELECTRICAL CONT.
PV EE 3.0 ELECTRICAL CONT.
PV EE 4.0 ELECTRICAL CONT.
PV SR 1.0 STRUCTURAL
PV CS 1.0 CUTSHEETS
PV CS 2.0 CUTSHEETS CONT.
7.15
9.75
REVISION 1
BCPR2021-0009
REVISED PANEL MANUFACTURER &
MODELS + REVISED RACKING AND
ATTACHMENT SYSTEM.
NEW SYSTEM ATTRIBUTES:
PLAN 7: OPTION OF 7.04kW OR 7.15kW
SOLAR ARRAY - (22) 320W OR 325W
MODULES (OPTION OF JA SOLAR
JAM60S17-320/MR OR JAM60S17-325/MR
MODULES) + SOLAREDGE P370 OPTIMIZERS
W/ (1) SOLAREDGE SE7600H-US INVERTER
[360SF].
PLAN 7 W/ CASITA: OPTION OF 9.6kW OR
9.75kW SOLAR ARRAY - (30) 320W OR 325W
MODULES (OPTION OF JA SOLAR
JAM60S17-320/MR OR JAM60S17-325/MR
MODULES) + SOLAREDGE P370 OPTIMIZERS
W/ (1) SOLAREDGE SE7600H-US INVERTER
[360SF].
12/09/2021
PLAN 7X & PLAN 7X W/ CASITA
IMAC
I MAC I MAC
IMAC
I MAC
IMAC
I MAC
IMAC
PV RL 1.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 7X
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: A
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
SYSTEM SIZE:
22 MODULES AT 7.040 kW DC
OR
22 MODULES AT 7.150 kW DC
12/09/2021
IMAC
I MAC I MAC
IMAC
I MAC
IMAC
I MAC
IMAC
PV RL 2.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12
LAYOUT 13 LAYOUT 14 LAYOUT 15 LAYOUT 16
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 7X
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: A
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
ELEVATION: A
OPTION(S): CASITA ADDITION
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
SYSTEM SIZE:
30 MODULES AT 9.600 kW DC
OR
30 MODULES AT 9.750 kW DC
12/09/2021
IMAC
I MAC I MAC
IMAC
I MAC
IMAC
I MAC
IMAC
PV RL 3.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 7X
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: B
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
SYSTEM SIZE:
22 MODULES AT 7.040 kW DC
OR
22 MODULES AT 7.150 kW DC
12/09/2021
IMAC
I MAC I MAC
IMAC
I MAC
IMAC
I MAC
IMAC
PV RL 4.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
LAYOUT 9 LAYOUT 10 LAYOUT 11 LAYOUT 12
LAYOUT 13 LAYOUT 14 LAYOUT 15 LAYOUT 16
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 7X
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: B
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
ELEVATION: B
OPTION(S): CASITA ADDITION
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
SYSTEM SIZE:
30 MODULES AT 9.600 kW DC
OR
30 MODULES AT 9.750 kW DC
12/09/2021
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 1.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
*INVERTER AND DISCONNECTING
MEANS TO BE INSTALLED IN GARAGE.
FOR MODEL HOME(S) WITH SALES
OFFICE, INVERTER AND
DISCONNECTING MEANS TO BE
INSTALLED OUTSIDE WITHIN SIGHT OF
MSP.
12/09/2021
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 2.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
*INVERTER AND DISCONNECTING
MEANS TO BE INSTALLED IN GARAGE.
FOR MODEL HOME(S) WITH SALES
OFFICE, INVERTER AND
DISCONNECTING MEANS TO BE
INSTALLED OUTSIDE WITHIN SIGHT OF
MSP.
12/09/2021
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 3.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
*INVERTER AND DISCONNECTING
MEANS TO BE INSTALLED IN GARAGE.
FOR MODEL HOME(S) WITH SALES
OFFICE, INVERTER AND
DISCONNECTING MEANS TO BE
INSTALLED OUTSIDE WITHIN SIGHT OF
MSP.
12/09/2021
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 4.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
*INVERTER AND DISCONNECTING
MEANS TO BE INSTALLED IN GARAGE.
FOR MODEL HOME(S) WITH SALES
OFFICE, INVERTER AND
DISCONNECTING MEANS TO BE
INSTALLED OUTSIDE WITHIN SIGHT OF
MSP.
12/09/2021
STRUCTURAL
ENGINEERING LETTER
STRUCTURAL CALCULATIONS
MOUNT DETAILS
PV SR 1.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
1 SNAPNRACK ULTRA RAIL STANDOFF BASE
NOT TO SCALE 2 SNAPNRACK GROUND LUG R PRC
NOT TO SCALE
4 SNAPNRACK CONDUIT MOUNT DETAIL
NOT TO SCALE
SHEATHING, TYP.
SNAPNRACK STANDOFF
BASE STD 4-HOLE, TYP SUB-FLASHING CONE, TYP
FLASHING
CONE, TYP
TILE, TYP
CONDUIT SUPPORT
CONDUIT
TILE HOOK
TILE, TYP
SHEATHING, TYP
NOTE: TILE HOOK TO BE PLACED AT
THE HIGH POINT OF S & W TILES
SEAL PENETRATION AND BASE
WITH CHEMLINK DURALINK 35
05.17.2021
FRAMING, TYP.
2-1/2"
(2) 5/16" SS LAG
SCREW, TYP.
3 SNAPNRACK MOUNT SPACING TYP.
NOT TO SCALE
CANTILEVER
L/3 OR
LESS
LANDSCAPE:
MAX 48"
SPACING (L)
PORTRAIT:
MAX 48"
SPACING (L)
MODULE, TYP.
FRAMING, TYP.
CANTILEVER
L/3 OR
LESS
MID CLAMP, TYP.MAX 10" - 16"
CANTILEVER,
TYP *
MAX
10"-16"
CANTILEVER,
TYP
*
MAX
10"
CANTILEVER,
TYP
*
MAX
10"
CANTILEVER,
TYP *
UR-60 RAIL, TYP.
ENDCLAMP, TYP.
*DEFER TO MODULE MANUFACTURER LIMITATIONS WHERE
THEIR MAXIMUM VERTICAL CANTILEVER IS SMALLER
ULTRA FOOT,
TYP.
SIDE VIEW
BONDING CHANNEL NUT
CONDUCTOR CONNECTS TO
ANOTHER GROUND LUG ON
BOTTOM RAIL OF ABOVE ROW
OF MODULES
GROUND LUG R PRC
SS SPLIT LOCK WASHER
GROUND CONDUCTOR
UR-60 RAIL
FRONT VIEW
UR-60 RAIL
12/09/2021
CUTSHEETS
OPTIMIZER
INVERTER
MODULE
PV CS 1.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
1
1S
T
R
E
V
I
E
W
9/
4
/
2
0
2
0
12/09/2021
CUTSHEETS CONT.
RACKING
AC DISCONNECT
PV CS 2.0
PV SYSTEM PROVIDED BY:
vivint.Solar
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
DESERT ESTATES
78-401 HWY 111 SUITE X
LA QUINTA, CA 92253
RANCHO SANTANA
LA QUINTA, CA
PLAN: 7X
DATE: 11/8/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
12/09/2021