BPOL2024-0205BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 07/26/2024
ISSUED DATE: 08/02/2024
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Pool
78410 HERITAGE WAY
BPOL2024-0205
643240033
Lot 34 MB 390/1 TR 31348 AMEND
$35,000.00
RL, 34
Owner:Moises Ramirez
Applicant:TESERRA TESERRA
38822 El Desierto Rd P O BOX 1280, Palm Desert,
CA 92211
Contractor:TESERRA TESERRA / 656128
38822 El Desierto Rd P O BOX 1280, Palm Desert,
CA 92211
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 3/14/25 4:39 pm Page 1 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0205
78410 HERITAGE WAY
BUILDING PERMIT
construction lender preliminary notice from that duty.
Printed: 3/14/25 4:39 pm Page 2 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0205
78410 HERITAGE WAY
BUILDING PERMIT
TESERRA / NEW POOL AND SPA IN BACKYARD WITH POOL EQIUPMENT AT SIDE YARD [FERRELL ENGINEERING]. THIS PERMIT DOES
NOT INCLUDE OTHER NEW EQUIPMENT ENCLOSURES, WALLS, BBQ ISLANDS, PATIO COVERS, WATER FEATURES OR FIREPITS
NOT DEPICTED ON THIS PLAN. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE
FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022
CALIFORNIA BUILDING CODE.
Use of Permit
Construction Details
Doug FarrellEngineer of Record 0Quantity of Detached
Spa(s)/Water
Feature(s)
4BBQ Electrical (EA)
1Number of Gas
Outlet(s)
0Mechanical Equipment
Relocation (QTY)
0Garden Wall Linear
Foootage
0Combination Retaining
Wall Linear Footage
0Total Wall Length
(Linear Footage)
RLZoning
LDRGeneral Plan Within La Quinta LimitsCity Limits TR 31348 AMENDSubdivision Name
34Lot Number 1253.82Lot Size 87927Centerlines
Lot 34 MB 390/1 TR 31348
AMEND
Legal Description
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
INV-00008302 $30.51 Receptacle, switch, lighting, or other outlets PC $30.51
$12.00 Digital Archiving and Records Management Fee - OTC $12.00
$228.84 Swimming Pool / Spa $228.84
$30.51 Receptacle, switch, lighting, or other outlets $30.51
$2.00 Building Standards Administration $2.00
$124.49 Swimming Pool / Spa PC $124.49
$30.51 Gas Piping System Outlets PC $30.51
$15.26 Gas Piping System Outlets $15.26
$8.00 Technology Enhancement Fee $8.00
$482.12 $482.12 Total for Invoice INV-00008302
Grand Total for Permit $482.12 $482.12
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Application Completeness Check v.1 07/26/2024 12:31 07/26/2024 12:31
Submittal Document Verification v.1 Generic Action 07/26/2024 12:31
Plan Check v.1 07/26/2024 0:00 07/31/2024 9:08
Building Review (1 Day) v.1 Receive Submittal 07/26/2024 0:00 07/31/2024 9:08
Permit Issuance v.1 07/31/2024 9:08 08/02/2024 14:59
Verify Contractor info & Conditions have been met v.1 Generic Action 07/31/2024 9:09
Verify & Invoice Fees v.1 Generic Action 07/31/2024 9:09
Verify Fee Payment & Issue Permit v.1 Generic Action 08/02/2024 14:59
Printed: 3/14/25 4:39 pm Page 3 of 4
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2024-0205
78410 HERITAGE WAY
BUILDING PERMIT
Print, Attach, and Email Building Permit v.1 Create Report 08/02/2024 14:59 08/02/2024 14:59
Pool Permit Inspection v.1 08/27/2024 0:00
Pre-Gunite v.1 Inspection 08/27/2024 0:00 08/28/2024 9:28
Underground Plumbing v.1 Inspection 10/11/2024 0:00 10/14/2024 10:31
Underground Electrical v.1 Inspection 10/11/2024 0:00 10/14/2024 10:31
Underground Gas v.1 Inspection 10/11/2024 0:00 10/14/2024 10:31
Deck Bond v.1 Inspection 10/24/2024 0:00 10/25/2024 9:26
Pre-Plaster v.1 Inspection 12/09/2024 0:00 12/10/2024 11:19
Footing v.1 Inspection
Bond Beam v.1 Inspection
Inspections - Final v.1 12/18/2024 0:00 12/23/2024 14:05
Final Pool v.1 Inspection 12/18/2024 0:00 12/19/2024 13:44
Final Pool v.2 Inspection 12/20/2024 0:00 12/23/2024 14:05
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 3/14/25 4:39 pm Page 4 of 4
Bu
i
l
d
e
r
s
o
f
E
x
c
e
p
t
i
o
n
a
l
O
u
t
d
o
o
r
L
i
v
i
n
g
34
50
50
SL
20
40
SH
FX
TEMP. GL.
1670FX
TEMP. GL.
1670
30
50
SH
20
40
SH
20
40
SH
26
46
SH
26
46
SH
3050SH3050SH3050SH
30
50
SH
30
50
SH
FX
ARCHED
2046 FX
ARCHED
2046
TE
M
P
.
G
L
.
60
50
SL
30
50
SH
FX
ARCHED
2046
8050XOX
71'-9"
PL
PL
PL
PL
4'-0" WD
TJa
G
CL
137'-8"
71'-6"
131'-4"
26'
G
A
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
4'-0" WD4'-3" WD
PBPB
CL
22'23'-6"
14'-5"
5'-4"
5'
12'
H
L
LM
H
USUS
A
S
25'-1"
SCALE:1/2"=1'-0"
8"
13"
18"
24"
7"
21"
21"
42"
18"
12"
SCALE:1/2"=1'-0"
21"
21"
42"
18"
1'-6"
1'-2"
1'-2"
10 1
2"
10 1
2"
1'-5"
18"
18"
SCALE:NOT TO SCALE
1
A
18"
18"
12"18"
38
8
2
2
E
L
D
E
S
I
E
R
T
O
R
D
.
P
A
L
M
D
E
S
E
R
T
C
A
9
2
2
1
1
PH
:
(
7
6
0
)
3
4
0
-
9
0
0
0
F
A
X
:
(
7
6
0
)
3
9
8
-
9
2
5
5
CA
L
I
C
E
N
S
E
N
o
.
6
5
6
1
2
8
SPECIFICATIONS
A CUSTOM PROJECT FOR:
REVISIONS DATE:
123456
SELECTIONS
CONSTRUCTION AUTHORIZATION
decking
excavation / steel
spa specifications
plumbing
gunite
owner responsibilities
masonry
pebble / plaster
fencing
MISCELLANEOUS
NAME
COMMUNITY
JOB ADDRESS CITY
HOMEOWNER MOBILE
PROJECT MANAGER MOBILE
DATE DESIGNED BY PROJECT MGR.CHECKED BYSCALE
MB #
18"=1'
TILE
PEBB/PLAS
BOULDERS
DRAINAGE NOTE:
DIG
PRE-GUNITE
UNDERGROUND
MASONRY
DECK
PRE-PEBBLE
SALES FIELD
SIGNATURE(S)DATE
(1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION.
(2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF
LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT.
(3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED.
(4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS,
AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA.
(5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE
PRIOR TO PREPLASTER INSPECTION.
(6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS -- DO NOT USE RUBBER HOSE )
(7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT
WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW.
OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE.
OWNER TO:
SIZE
SURFACE AREA OF POOL ONLY
PERIMETER DEPTHS MIN.MAX
X
SIZE X SQ. FT.
SPA DAM WALL WIDTH
NO. OF JETS
LIGHT
RAISED SPA AT
SPILLWAY TYPE
SPECIAL NOTES
GLASS TILE
WATERLINE
R.B.B. TILE
TYPE
ACCESS FROM
ELEVATION
DEEP END RAMP
LOVE SEAT
CONCRETE REMOVAL
SOD REMOVAL
TREE REMOVAL BY
LOADS
LOADS
IRRIGATION REMOVAL BY
IRRIGATION REPAIR
FT.
TAN SHELF DEPTH
ROCK POCKETS
CENTERS
FILTER SIZE
POOL PUMP
BOOSTER PUMP
ADDL PUMP
ADDL PUMP
HEATER
CONTROL SYSTEM
CHLORINATOR
WIRELESS CONTROL
SKIMMER TYPE
FILL LINE
GAS LINE STUBS
W.F. ATTACHED TO POOL
OTHER W.F.
LIGHTS IN POOL
STUB SET EQUIPMENT
DEEP END RAMP
EXTEND 2nd STEP
LOVESEAT
COPING
R.B.B. - SEE STEEL
REMOVE & REHANG
GATE REVERSAL
GATE
HEIGHT
FENCE TYPE
DEEP HEAT RETURNS
ECLIPSE DRAINS
EYE BALL FITTINGS
LIGHTS SPA
LIGHTS POOL
SEAT WALLS
EQUIP. WALLS
RETAINING WALLS
PLANTER WALL
PROP. EXT. WALLS
STEPS
SPILLWAY TYPE SIZE
R.B.B. FACING
COPING TYPE
MOW STRIP
BANDS
SAND AND VISQUEEN
TILE BASE
STEP FACE
STEPS
SLEEVES
DRAINS
DOUBLE CANTILEVER
CANTILEVER
EXPANSION JOINTS
FINISH
SQ. FT.
TILE
SIZE
SIZE
SIZE
SIZE
SIZE
EST. START
EST. COMPLETION
30" R.B.B.
Drainage and irrigation for planters and pots, by others,
unless otherwise noted.
LN. FT.
POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS
ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY,
FIELD LAYOUT WILL VARY
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS
TO THE POOL
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114 - MANDATORY REQUIREMENTS
* NO EXISTING LANDSCAPE LIGHTING IN REAR YARD
* NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD
78
POOL & SPA COMBINED
* PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY
FT.24" R.B.B.
FT.18" R.B.B.
FT.12" R.B.B.
FT.6" R.B.B.
PLUMBING SIZE
PROJECT MANAGER EMAIL
TRIM TILE
EQUIPOTENTIAL BONDING GRID
WELDED WIRE MESH
REBAR
BARBECUE COUNTERTOP
BARBECUE
SAND SET PAVERS
STUCCO
PAINT
Q360 INFLOOR
MISTING SYSTEM
TRELLIS
LIGHTS IN SPA
LIGHTS IN W.F.
DEEP HEAT PACKAGE
Q360 INFLOOR
MISC.
PAVERS
HOMEOWNER EMAIL
FIREPIT
ANTI VORTEX
ECLIPSE DRAINS
ANTI VORTEX
CUSTOMER NUMBER:
DBX #
2022 california building code ( BASED ON 2018 IBC )
2022 california mechanical code ( BASED ON 2018 UMC )
2022 california electrical code ( BASED ON 2017 NEC )
2022 california energy green code
electrical:
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE
GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26.
safety features:
* ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN
SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
2022 california plumbing code ( BASED ON 2018 UPC )TITLE 24, PART 5
GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL
DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED
IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE
INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR
NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR
OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED
2022 california residential code ( BASED ON 2018 IRC )
2022 california energy code
1-NICHELESS HYDROCOOL COLOR LED
NPT: LIGHT WAVES LWV - BLUE 2 x 2
NPT: WRF ANGEL WATERFALL ANG BLUE 6 x 6
BELGARD DIMENSIONS 12 COLOR VICTORIAN
NATURAL GRAY BROOM FINISH
AQUA BLUE PEBBLE SHEEN
HERITAGE WAY
5 PER PLAN
-0-
DAM WALL
BOBCAT
SEE SUPER
SEE SUPER
-
-
-
-
-
-
-
-
-
BROOM
YES
YES TO STREET
YES TO PLAN
-
YES
-
-
-
-
DAM WALL -
CONCRETE
1-NICHELESS HYDROCOOL COLOR LED
3-NICHELESS HYDROCOOL COLOR LED
1-NICHELESS HYDROCOOL COLOR LED
3-NICHELESS HYDROCOOL COLOR LED
-
-
-
-
-
JANDY
JANDY
460 SQ.FT.
VS HP 270 AUT
JANDY JXI NK
IQ 904 PS
-
DUAL PORT
F.M.
AUTO
-
CONCRETE
-
-
YES
-
-
YES
-
-
IQ 30-A
--
--
-
-
GUNITE 26'-0"12'-0"
361 SQ.FT.
85 LN.FT.
412 SQ.FT. / 99 LN.FT.
4'-0"4'-3"
8'-0"6'-0"48 28
SEE NOTES
42' - 11
2" POLYPROPYLENE GAS PIPE
MAIN HOUSE 200 AMP ELECTRICAL PANEL
GAS METER
ELECTRIC CONDUIT
COLORED CONCRETE WALKWAY
TO MATCH DRIVEWAY
EXISTING 5'-0"H BLOCK WALL
EXISTING 5'-0"H BLOCK WALL
EXISTING 5'-0"H SELF LATCHING/SELF
CLOSING GATE - OPENING OUT
POOL / SPA LIGHT JUNCTION BOX
POOL / SPA LIGHT ON GROUND
FAULT CIRCUIT INTERRUPTER
POOL EQUIPMENT 50 AMP SUBPANEL
WITH 36" CLEARANCE AT FRONT AND SIDE
TRANSFORMER
SPA AIR LINE
POOL EQUIPMENT: 400,000 BTU HEATER, VERSA FLOW,
*ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED
POOL SPLIT MAIN DRAIN SUCTION
MINIMUM 3' APART. ANTI-COVERS
10" ASME / ANSI APPROVED
SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.
ANTI-COVERS 10" ASME / ANSI APPROVED
SPA STEP
SPA AT 0" WITH 12" WIDE TILE DAM WALL, DAM
WALL WIDTH TO BE 10 1/2" FINISHED GUNITE, 6"
TILE WATERLINE, (5) JETS PER PLAN
NATURAL GRAY BROOM FINISH
CONCRETE COPING AROUND POOL
EXISTING 5'-0"H BLOCK WALL
152 SQ. FT.CONCRETE COPING
CONCRETE BY
BUILDER
1924 SQ. FT.PAVER DECKING AND WALKWAY
153 SQ. FT.CONCRETE WALKWAY
BELGARD DIMENSIONS 12 PAVER DECKING SAND
SET OVER COMPACTED ROAD BASE AND +/-1" OF
BEDDING SAND, POLYMERIC SAND GROUT, MUD
SET PERIMETER
BELGARD DIMENSIONS 12 PAVER DECKING SAND
SET OVER COMPACTED ROAD BASE AND +/-1" OF
BEDDING SAND, POLYMERIC SAND GROUT, MUD
SET PERIMETER
4" PVC DRAIN RUNNING
TO FRONT BUBBLER
4" PVC DRAIN RUNNING
TO FRONT BUBBLER
BUBBLER BOX
BUBBLER BOX
4" DECK DRAINS TO TIE
INTO LATERAL DRAIN LINES
BELGARD DIMENSIONS 12 PAVER WALKWAY SAND
SET OVER COMPACTED ROAD BASE AND +/-1" OF
BEDDING SAND, POLYMERIC SAND GROUT, MUD
SET PERIMETER
(1) 4" SLEEVE TO
LANDLOCKED PLANTER BED
(1) 4" SLEEVE TO
LANDLOCKED PLANTER BED
(2) 4" SLEEVES
STEPS AND BENCHES IN
POOL AND SPA TO HAVE
TRIM TILE. TILE TO BE NPT
LIGHTWAVES LWV BLUE 2x2
DRAIN HEADS IN LANDLOCKED PLANTER BED
DRAIN HEADS IN LANDLOCKED PLANTER BED
DRAINAGE SYSTEM
TO BE INSTALLED
DURING COURSE OF
CONSTRUCTION
400K BTU
VERSA FLOW
CONCRETE
TRIM TILE
STONE
CONCRETECOPING
FLAGSTONE BROWN TO MATCH DRIVEWAYBROOM FINISHFRONT YARD
COPING
07/30/2024Edward Ghera
BPOL2024-0205
TESERRA / NEW POOL AND SPA IN BACKYARD WITH POOL
EQIUPMENT AT SIDE YARD [FERRELL ENGINEERING]. THIS
PERMIT DOES NOT INCLUDE OTHER NEW EQUIPMENT
ENCLOSURES, WALLS, BBQ ISLANDS, PATIO COVERS,
WATER FEATURES OR FIREPITS NOT DEPICTED ON THIS
PLAN. APPROVED SITE PLAN AND WET STAMPED POOL
ENGINEERING SHEET REQUIRED TO BE ONSITE FOR
INSPECTION. TWO DROWNING PREVENTION SAFETY
FEATURES SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
4' MINIMUM SETBACK
FROM OPERABLE
WINDOWS REQUIRED