Loading...
BPOL2024-0205BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 07/26/2024 ISSUED DATE: 08/02/2024 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 78410 HERITAGE WAY BPOL2024-0205 643240033 Lot 34 MB 390/1 TR 31348 AMEND $35,000.00 RL, 34 Owner:Moises Ramirez Applicant:TESERRA TESERRA 38822 El Desierto Rd P O BOX 1280, Palm Desert, CA 92211 Contractor:TESERRA TESERRA / 656128 38822 El Desierto Rd P O BOX 1280, Palm Desert, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 3/14/25 4:39 pm Page 1 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2024-0205 78410 HERITAGE WAY BUILDING PERMIT construction lender preliminary notice from that duty. Printed: 3/14/25 4:39 pm Page 2 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2024-0205 78410 HERITAGE WAY BUILDING PERMIT TESERRA / NEW POOL AND SPA IN BACKYARD WITH POOL EQIUPMENT AT SIDE YARD [FERRELL ENGINEERING]. THIS PERMIT DOES NOT INCLUDE OTHER NEW EQUIPMENT ENCLOSURES, WALLS, BBQ ISLANDS, PATIO COVERS, WATER FEATURES OR FIREPITS NOT DEPICTED ON THIS PLAN. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Use of Permit Construction Details Doug FarrellEngineer of Record 0Quantity of Detached Spa(s)/Water Feature(s) 4BBQ Electrical (EA) 1Number of Gas Outlet(s) 0Mechanical Equipment Relocation (QTY) 0Garden Wall Linear Foootage 0Combination Retaining Wall Linear Footage 0Total Wall Length (Linear Footage) RLZoning LDRGeneral Plan Within La Quinta LimitsCity Limits TR 31348 AMENDSubdivision Name 34Lot Number 1253.82Lot Size 87927Centerlines Lot 34 MB 390/1 TR 31348 AMEND Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00008302 $30.51 Receptacle, switch, lighting, or other outlets PC $30.51 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $228.84 Swimming Pool / Spa $228.84 $30.51 Receptacle, switch, lighting, or other outlets $30.51 $2.00 Building Standards Administration $2.00 $124.49 Swimming Pool / Spa PC $124.49 $30.51 Gas Piping System Outlets PC $30.51 $15.26 Gas Piping System Outlets $15.26 $8.00 Technology Enhancement Fee $8.00 $482.12 $482.12 Total for Invoice INV-00008302 Grand Total for Permit $482.12 $482.12 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 07/26/2024 12:31 07/26/2024 12:31 Submittal Document Verification v.1 Generic Action 07/26/2024 12:31 Plan Check v.1 07/26/2024 0:00 07/31/2024 9:08 Building Review (1 Day) v.1 Receive Submittal 07/26/2024 0:00 07/31/2024 9:08 Permit Issuance v.1 07/31/2024 9:08 08/02/2024 14:59 Verify Contractor info & Conditions have been met v.1 Generic Action 07/31/2024 9:09 Verify & Invoice Fees v.1 Generic Action 07/31/2024 9:09 Verify Fee Payment & Issue Permit v.1 Generic Action 08/02/2024 14:59 Printed: 3/14/25 4:39 pm Page 3 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2024-0205 78410 HERITAGE WAY BUILDING PERMIT Print, Attach, and Email Building Permit v.1 Create Report 08/02/2024 14:59 08/02/2024 14:59 Pool Permit Inspection v.1 08/27/2024 0:00 Pre-Gunite v.1 Inspection 08/27/2024 0:00 08/28/2024 9:28 Underground Plumbing v.1 Inspection 10/11/2024 0:00 10/14/2024 10:31 Underground Electrical v.1 Inspection 10/11/2024 0:00 10/14/2024 10:31 Underground Gas v.1 Inspection 10/11/2024 0:00 10/14/2024 10:31 Deck Bond v.1 Inspection 10/24/2024 0:00 10/25/2024 9:26 Pre-Plaster v.1 Inspection 12/09/2024 0:00 12/10/2024 11:19 Footing v.1 Inspection Bond Beam v.1 Inspection Inspections - Final v.1 12/18/2024 0:00 12/23/2024 14:05 Final Pool v.1 Inspection 12/18/2024 0:00 12/19/2024 13:44 Final Pool v.2 Inspection 12/20/2024 0:00 12/23/2024 14:05 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 3/14/25 4:39 pm Page 4 of 4 Bu i l d e r s o f E x c e p t i o n a l O u t d o o r L i v i n g 34 50 50 SL 20 40 SH FX TEMP. GL. 1670FX TEMP. GL. 1670 30 50 SH 20 40 SH 20 40 SH 26 46 SH 26 46 SH 3050SH3050SH3050SH 30 50 SH 30 50 SH FX ARCHED 2046 FX ARCHED 2046 TE M P . G L . 60 50 SL 30 50 SH FX ARCHED 2046 8050XOX 71'-9" PL PL PL PL 4'-0" WD TJa G CL 137'-8" 71'-6" 131'-4" 26' G A S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S GA S 4'-0" WD4'-3" WD PBPB CL 22'23'-6" 14'-5" 5'-4" 5' 12' H L LM H USUS A S 25'-1" SCALE:1/2"=1'-0" 8" 13" 18" 24" 7" 21" 21" 42" 18" 12" SCALE:1/2"=1'-0" 21" 21" 42" 18" 1'-6" 1'-2" 1'-2" 10 1 2" 10 1 2" 1'-5" 18" 18" SCALE:NOT TO SCALE 1 A 18" 18" 12"18" 38 8 2 2 E L D E S I E R T O R D . P A L M D E S E R T C A 9 2 2 1 1 PH : ( 7 6 0 ) 3 4 0 - 9 0 0 0 F A X : ( 7 6 0 ) 3 9 8 - 9 2 5 5 CA L I C E N S E N o . 6 5 6 1 2 8 SPECIFICATIONS A CUSTOM PROJECT FOR: REVISIONS DATE: 123456 SELECTIONS CONSTRUCTION AUTHORIZATION decking excavation / steel spa specifications plumbing gunite owner responsibilities masonry pebble / plaster fencing MISCELLANEOUS NAME COMMUNITY JOB ADDRESS CITY HOMEOWNER MOBILE PROJECT MANAGER MOBILE DATE DESIGNED BY PROJECT MGR.CHECKED BYSCALE MB # 18"=1' TILE PEBB/PLAS BOULDERS DRAINAGE NOTE: DIG PRE-GUNITE UNDERGROUND MASONRY DECK PRE-PEBBLE SALES FIELD SIGNATURE(S)DATE (1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA. (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS -- DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. OWNER TO: SIZE SURFACE AREA OF POOL ONLY PERIMETER DEPTHS MIN.MAX X SIZE X SQ. FT. SPA DAM WALL WIDTH NO. OF JETS LIGHT RAISED SPA AT SPILLWAY TYPE SPECIAL NOTES GLASS TILE WATERLINE R.B.B. TILE TYPE ACCESS FROM ELEVATION DEEP END RAMP LOVE SEAT CONCRETE REMOVAL SOD REMOVAL TREE REMOVAL BY LOADS LOADS IRRIGATION REMOVAL BY IRRIGATION REPAIR FT. TAN SHELF DEPTH ROCK POCKETS CENTERS FILTER SIZE POOL PUMP BOOSTER PUMP ADDL PUMP ADDL PUMP HEATER CONTROL SYSTEM CHLORINATOR WIRELESS CONTROL SKIMMER TYPE FILL LINE GAS LINE STUBS W.F. ATTACHED TO POOL OTHER W.F. LIGHTS IN POOL STUB SET EQUIPMENT DEEP END RAMP EXTEND 2nd STEP LOVESEAT COPING R.B.B. - SEE STEEL REMOVE & REHANG GATE REVERSAL GATE HEIGHT FENCE TYPE DEEP HEAT RETURNS ECLIPSE DRAINS EYE BALL FITTINGS LIGHTS SPA LIGHTS POOL SEAT WALLS EQUIP. WALLS RETAINING WALLS PLANTER WALL PROP. EXT. WALLS STEPS SPILLWAY TYPE SIZE R.B.B. FACING COPING TYPE MOW STRIP BANDS SAND AND VISQUEEN TILE BASE STEP FACE STEPS SLEEVES DRAINS DOUBLE CANTILEVER CANTILEVER EXPANSION JOINTS FINISH SQ. FT. TILE SIZE SIZE SIZE SIZE SIZE EST. START EST. COMPLETION 30" R.B.B. Drainage and irrigation for planters and pots, by others, unless otherwise noted. LN. FT. POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY, FIELD LAYOUT WILL VARY EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD * NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD 78 POOL & SPA COMBINED * PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY FT.24" R.B.B. FT.18" R.B.B. FT.12" R.B.B. FT.6" R.B.B. PLUMBING SIZE PROJECT MANAGER EMAIL TRIM TILE EQUIPOTENTIAL BONDING GRID WELDED WIRE MESH REBAR BARBECUE COUNTERTOP BARBECUE SAND SET PAVERS STUCCO PAINT Q360 INFLOOR MISTING SYSTEM TRELLIS LIGHTS IN SPA LIGHTS IN W.F. DEEP HEAT PACKAGE Q360 INFLOOR MISC. PAVERS HOMEOWNER EMAIL FIREPIT ANTI VORTEX ECLIPSE DRAINS ANTI VORTEX CUSTOMER NUMBER: DBX # 2022 california building code ( BASED ON 2018 IBC ) 2022 california mechanical code ( BASED ON 2018 UMC ) 2022 california electrical code ( BASED ON 2017 NEC ) 2022 california energy green code electrical: EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. safety features: * ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) 2022 california plumbing code ( BASED ON 2018 UPC )TITLE 24, PART 5 GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED 2022 california residential code ( BASED ON 2018 IRC ) 2022 california energy code 1-NICHELESS HYDROCOOL COLOR LED NPT: LIGHT WAVES LWV - BLUE 2 x 2 NPT: WRF ANGEL WATERFALL ANG BLUE 6 x 6 BELGARD DIMENSIONS 12 COLOR VICTORIAN NATURAL GRAY BROOM FINISH AQUA BLUE PEBBLE SHEEN HERITAGE WAY 5 PER PLAN -0- DAM WALL BOBCAT SEE SUPER SEE SUPER - - - - - - - - - BROOM YES YES TO STREET YES TO PLAN - YES - - - - DAM WALL - CONCRETE 1-NICHELESS HYDROCOOL COLOR LED 3-NICHELESS HYDROCOOL COLOR LED 1-NICHELESS HYDROCOOL COLOR LED 3-NICHELESS HYDROCOOL COLOR LED - - - - - JANDY JANDY 460 SQ.FT. VS HP 270 AUT JANDY JXI NK IQ 904 PS - DUAL PORT F.M. AUTO - CONCRETE - - YES - - YES - - IQ 30-A -- -- - - GUNITE 26'-0"12'-0" 361 SQ.FT. 85 LN.FT. 412 SQ.FT. / 99 LN.FT. 4'-0"4'-3" 8'-0"6'-0"48 28 SEE NOTES 42' - 11 2" POLYPROPYLENE GAS PIPE MAIN HOUSE 200 AMP ELECTRICAL PANEL GAS METER ELECTRIC CONDUIT COLORED CONCRETE WALKWAY TO MATCH DRIVEWAY EXISTING 5'-0"H BLOCK WALL EXISTING 5'-0"H BLOCK WALL EXISTING 5'-0"H SELF LATCHING/SELF CLOSING GATE - OPENING OUT POOL / SPA LIGHT JUNCTION BOX POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER POOL EQUIPMENT 50 AMP SUBPANEL WITH 36" CLEARANCE AT FRONT AND SIDE TRANSFORMER SPA AIR LINE POOL EQUIPMENT: 400,000 BTU HEATER, VERSA FLOW, *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED SPA STEP SPA AT 0" WITH 12" WIDE TILE DAM WALL, DAM WALL WIDTH TO BE 10 1/2" FINISHED GUNITE, 6" TILE WATERLINE, (5) JETS PER PLAN NATURAL GRAY BROOM FINISH CONCRETE COPING AROUND POOL EXISTING 5'-0"H BLOCK WALL 152 SQ. FT.CONCRETE COPING CONCRETE BY BUILDER 1924 SQ. FT.PAVER DECKING AND WALKWAY 153 SQ. FT.CONCRETE WALKWAY BELGARD DIMENSIONS 12 PAVER DECKING SAND SET OVER COMPACTED ROAD BASE AND +/-1" OF BEDDING SAND, POLYMERIC SAND GROUT, MUD SET PERIMETER BELGARD DIMENSIONS 12 PAVER DECKING SAND SET OVER COMPACTED ROAD BASE AND +/-1" OF BEDDING SAND, POLYMERIC SAND GROUT, MUD SET PERIMETER 4" PVC DRAIN RUNNING TO FRONT BUBBLER 4" PVC DRAIN RUNNING TO FRONT BUBBLER BUBBLER BOX BUBBLER BOX 4" DECK DRAINS TO TIE INTO LATERAL DRAIN LINES BELGARD DIMENSIONS 12 PAVER WALKWAY SAND SET OVER COMPACTED ROAD BASE AND +/-1" OF BEDDING SAND, POLYMERIC SAND GROUT, MUD SET PERIMETER (1) 4" SLEEVE TO LANDLOCKED PLANTER BED (1) 4" SLEEVE TO LANDLOCKED PLANTER BED (2) 4" SLEEVES STEPS AND BENCHES IN POOL AND SPA TO HAVE TRIM TILE. TILE TO BE NPT LIGHTWAVES LWV BLUE 2x2 DRAIN HEADS IN LANDLOCKED PLANTER BED DRAIN HEADS IN LANDLOCKED PLANTER BED DRAINAGE SYSTEM TO BE INSTALLED DURING COURSE OF CONSTRUCTION 400K BTU VERSA FLOW CONCRETE TRIM TILE STONE CONCRETECOPING FLAGSTONE BROWN TO MATCH DRIVEWAYBROOM FINISHFRONT YARD COPING 07/30/2024Edward Ghera BPOL2024-0205 TESERRA / NEW POOL AND SPA IN BACKYARD WITH POOL EQIUPMENT AT SIDE YARD [FERRELL ENGINEERING]. THIS PERMIT DOES NOT INCLUDE OTHER NEW EQUIPMENT ENCLOSURES, WALLS, BBQ ISLANDS, PATIO COVERS, WATER FEATURES OR FIREPITS NOT DEPICTED ON THIS PLAN. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. 4' MINIMUM SETBACK FROM OPERABLE WINDOWS REQUIRED