Loading...
BSOL2022-0477BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 08/09/2022 ISSUED DATE: 09/27/2022 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar 48615 CALLE ESPERANZA BSOL2022-0477 646121008 $22,000.00 Owner:Mona Davidson 48615 Calle Esperanza, La Quinta, CA 92253 Applicant:KUUBIX GLOBAL LLC 7401 SUNNYVIEW AVE, VISALIA, CA 93291 Contractor:KUUBIX GLOBAL LLC 7401 SUNNYVIEW AVE, VISALIA, CA 93291 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 3/18/25 8:58 am Page 1 of 3 Permit Type: Permit Number: Property Address: Solar BSOL2022-0477 48615 CALLE ESPERANZA BUILDING PERMIT DAVIDSON / 7.4kW PV SYSTEM - (20) 370W PANELS/(1) INVERTER *** 7.4kW SOLAR ARRAY - (20) 370W BOVIET SOLAR BVM6610M-370S-H-HC-BF PANELS + SOLAREDGE S4400 POWER OPTIMIZERS W/ (1) SOLAREDGE SE6000H-US INVERTER [400SF] THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF THE SERVICE PANEL. 2019 CALIFORNIA BUILDING CODES. Use of Permit Construction Details 7.4System Size (kW DC)2PV Strings (EA) Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BSOL2022-047 7 $5.00 TECHNOLOGY ENHANCEMENT FEE $5.00 $27.79 PV SYSTEM LESS THAN 10KW PC $27.79 $27.79 PV SYSTEM LESS THAN 10KW $27.79 $1.00 BSAS SB1473 FEE $1.00 $105.60 PERMIT ISSUANCE $105.60 $11.00 RECORDS MANAGEMENT FEE $11.00 $178.18 $178.18 Total for Invoice PERMIT-BSOL2022-0477 Grand Total for Permit $178.18 $178.18 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 08/09/2022 0:00 SOLAR FINAL** v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy Printed: 3/18/25 8:58 am Page 2 of 3 Permit Type: Permit Number: Property Address: Solar BSOL2022-0477 48615 CALLE ESPERANZA BUILDING PERMIT A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 3/18/25 8:58 am Page 3 of 3 COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 48615 CALLE ESPERANZA, LA QUINTA, CA 92253, USA REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-0 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SYSTEM SUMMARY: ROOF TYPE: - W-TILE ROOF FRAME: - 2"X4" TRUSSES @24" O.C. STORY: - ONE STORY SNOW LOAD : - 0 PSF WIND SPEED :- 110 MPH WIND EXPOSURE:- C EXPOSURE CATEGORY:- II COORDINATE:- 33.696023, -116.303487 DESIGN CRITERIA:GOVERNING CODES: 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA GREEN CODE (CGC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CA FIRE CODE TITLE 24 SUPPLEMENT LA QUINTA MUNICIPAL CODE ANY OTHER LOCAL AMENDMENTS PROJECT SITE 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 ARRAY LOCATIONS 33.696023, -116.303487 PV-0 COVER SHEET PV-00 NOTES PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-2.1 ATTACHMENT PLAN PV-3&3.1 ATTACHMENT DETAILS PV-4 STRING LAYOUT PV-5 ELECTRICAL LINE DIAGRAM PV-6 ELECTRICAL CALCULATION PV-7 WARNING LABELS & PLACARD PV-8 ADDITIONAL NOTES PV-9 OPTIMIZER CHART PV-10+EQUIPMENT SPEC SHEETS SHEET INDEX 20 MODULES-ROOF MOUNTED - 7.40 kWDC, 6.0 kWAC (N) 20 - BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES (N) 01 - SOLAREDGE SE6000H-USRGM, [240V] INVERTER (N) 20 - SOLAREDGE S440 POWER OPTIMIZERS (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) 60A NON FUSED AC DISCONNECT GENERAL NOTES ·THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. ·REFER TO ELECTRICAL DRAWING PV-5 FOR PANEL DETAILED INFORMATION. ·IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. ·THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM. ·THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR TO PERFORMING THE WORK. ·ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES. · DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY. ·LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. ·LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. ·DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION PANEL. ·ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE BONDED. ·PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. ·RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE DC DISCONNECT. A A 26Sep 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY BSOL2022-0477 7.4kW SOLAR ARRAY - (20) 370W BOVIET SOLAR BVM6610M-370S-H-HC-BF PANELS + SOLAREDGE S4400 POWER OPTIMIZERS W/ (1) SOLAREDGE SE6000H-US INVERTER [400SF] THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF THE SERVICE PANEL. 2019 CALIFORNIA BUILDING CODES. 09/27/2022 NOTES REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-00 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION 2.1.1 SITE NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION CEC110.26. 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.2.1 EQUIPMENT LOCATIONS: 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY CEC 690.31(A),(C) AND CECTABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC690.34. 2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CECAPPLICABLE CODES. 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.3.1 STRUCTURAL NOTES: 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER AND/OR STRUCTURAL ENG. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHENTHE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS). 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D). 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC690.8, 690.9, AND 240. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH CEC110.3(B). 2.6.7 SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. 2.7.1 INTERCONNECTION NOTES: 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [CEC 705.12 (B)] 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER X 125% CONTINUOUS OUTPUT MAY NOT EXCEED 100% OF BUSBAR RATING [CEC 705.12(B)(2)(3)(A)]. 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC 705.12(B)(2)(3)(B)]. 2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO CEC 705.12 (B)(2)(3)(C). 2.7.6 FEEDER TAP INTERCONECTION (LOADSIDE) ACCORDING TO CEC 705.12 (B)(2)(1) 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO CEC705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH CEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [CEC 705.12 (B)(5)]. 2.7.8 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR CENTER FED, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END (NOT BOTH END) OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC 705.12(B)(2)(3)(d)]. 2.4.1 WIRING & CONDUIT NOTES: 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.4.3 CONDUCTORS SIZED ACCORDING TO CEC 690.8, CEC 690.7. 2.4.4 VOLTAGE DROP LIMITED TO 1.5%. 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC 110.15]. 2.6.8 LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D)" 2.5.1 GROUNDING NOTES: 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO CEC 690.43 AND MINIMUM CECTABLE 250.122. 2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC690.45 AND MICRO INVERTER MANUFACTURERS’ INSTRUCTIONS. 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF MODULE DOES NOT INTERRUPT A GROUNDING BOND TO ANOTHER MODULE. 2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [CEC 250.119] #6 BARE ALLOWED OUTSIDE OF RACEWAY. 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC690.47 AND CEC2019 690.47(B) AUXILIARY GROUND ELECTRODE REQUIRED. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC250, CEC690.47 AND AHJ. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH CEC690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS 09/27/2022 ACDMSPUMINV JB ~5 7 . 3 4 ' ~95.51' ~5 7 . 3 4 ' ~95.51' 8' - 8 " 17'-7" 23'-0" 3' - 5 " SITE PLAN WITH ROOF PLAN REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-1 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SITE PLAN WITH ROOF PLAN 1 SCALE: 1/8" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE: A.ALL ELECTRICAL EQUIPMENT, INVERTERS, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ SUPPLY OR DEMAND PIPING. 33.696023, -116.303487 CA L L E E S P E R A N Z A PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E EXISTING DRIVEWAY (E) GATE (TYP.)(E) TREE (TYP.) (E) FENCE ONE- STORY HOUSE ROOF #1 (4) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #2 (11) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #3 (5) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) 60A NON FUSED AC DISCONNECT (N) 3/4" OR GREATER EMT CONDUIT RUN (ABOVE 7/8 INCHES ABOVE ROOF) (N) SOLAREDGE SE6000H-USRGM, [240V] INVERTER ROOF ACCESS POINT 26Sep 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY 09/27/2022 ACDMSPUM INV JB REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-2 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 1/8" = 1'-0"1 70.63" 41 . 1 9 " PHOTOVOLTAIC MODULES BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 20 MODULES MODULE TYPE = BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES MODULE WEIGHT = 48.50 LBS / 22.0 KG. MODULE DIMENSIONS = 70.63"X 41.19" = 20.20 SF UNIT WEIGHT OF ARRAY = 2.40 PSF · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS 33.696023, -116.303487 LEGEND UM - UTILITY METER MSP - MAIN SERVICE PANEL ACD - AC DISCONNECT - JUNCTION BOXJB INV - INVERTER R324.6.2 - PROVING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA.WHEN THE ARRAYS TAKE LESS THAN 33% WE CAN JUSTIFY AN 18" SETBACK ON BOTH SIDES OF THE RIDGE. WHEN IT TAKES MORE THAN 33% OF THE ROOF AREA WE MUST USE A 3' SETBACKS AT THE RIDGE. TOTAL ROOF AREA: 2654.06 sqft AREA OF ARRAYS: 70.63"X 41.19" ( PANEL DIMENSIONS) 70.63"X 41.19" = 20.20 sqft (PER PANEL) 20.20 sqft panel X 20 panels = 404.06 sqft (TOTAL PANEL AREA) PERCENTAGE OF TOTAL ROOF AREA: (404.06 sqft / 2654.06 sqft)(100)= 15.22% ∴THE PANELS USE 15.22% OF THE TOTAL ROOF AREA BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 11 UNIRAC SM LIGHT RAIL 168" DARK SPLICE 02 BND SPLICE BAR PRO SERIES DRK MID CLAMP 30 UNIVERSAL AF SERIES MID CLAMP END CLAMP 20 UNIVERSAL AF SERIES END CLAMP ATTACHMENT 34 UNIRAC FLASH KIT TR ATTACHMENTS GROUNDING LUG 05 GROUND LUG WEEB SOLAR PV MODULE 20 BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES INVERTER 01 SOLAREDGE SE6000H-USRGM, [240V] INVERTER JUNCTION BOX 1 600V, 55A MAX, 4 INPUTS, MOUNTED ON ROOF FOR WIRE & CONDUIT TRANSITION AC DISCONNECT 1 240VAC, 60A NON FUSED AC DISCONNECT, NEMA 3R, UL LISTED OPTIMIZERS 20 SOLAREDGE S440 POWER OPTIMIZERS - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - TRUSSES - CONDUIT - FIRE PATHWAY - CHIMNEY CA L L E E S P E R A N Z A RE A R Y A R D FR O N T Y A R D 36" FIRE PATHWAY 18 " F I R E P A T H W A Y 18 " F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 18 " F I R E P A T H W A Y 18 " F I R E P A T H W A Y 36" FIRE PATHWAY ROOF #1 (4) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #2 (11) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #3 (5) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (E) UTILITY METER (N) 60A NON FUSED AC DISCONNECT (N) 3/4" OR GREATER EMT CONDUIT RUN (ABOVE 7/8 INCHES ABOVE ROOF) (N) SOLAREDGE SE6000H-USRGM, [240V] INVERTER ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 4 80.81 341.31 23.68 #2 11 222.23 667.57 33.29 #3 5 101.02 517.82 19.51 ROOF DESCRIPTION ROOF TYPE W-TILE ROOF ROOF ROOF TILT AZIMUTH TRUSSES SIZE TRUSSES SPACING #1 18°180°2"x4"24" O.C. #2 18°90°2"x4"24" O.C. #3 18°270°2"x4"24" O.C. ROOF #2 (11) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES (E) W-TILE ROOF (TYP.) (E) 2"X4" TRUSSES @ 24" O.C. (TYP.) (N) (34) UNIRAC FLASH KIT TR ATTACHMENTS SPACED AT 72" O.C. (N) UNIRAC SM LIGHT RAIL (TYP.) ROOF #1 TILT - 18 AZIMUTH - 180 ROOF #2 TILT - 18 AZIMUTH - 90 ROOF #3 TILT - 18 AZIMUTH - 270 26 Sep 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY NOTE:CONTRACTOR TO VERIFY EXISTING FRAMING AND STRUCTURAL LETTER NOTIFY EOR INCASE OF DISCRIPENCIES 09/27/2022 6'-0" 3' - 9 " 10 ' - 5 " 14 ' - 1 1 " 4'-0"11'-3"4'-0" 3'-3"5'-7"11'-6" 3' - 1 " 5' - 7 " 2' - 1 " SCALE: 1/8" = 1'-0"1 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-2.1 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ATTACHMENT PLAN ATTACHMENT PLAN 33.696023, -116.303487 NOTE: MAX CANTILEVER TO BE 24" CA L L E E S P E R A N Z A RE A R Y A R D FR O N T Y A R D ROOF #1 TILT - 18 AZIMUTH - 180 ROOF #2 TILT - 18 AZIMUTH - 90 ROOF #3 TILT - 18 AZIMUTH - 270 26 Sep 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-3 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ATTACHMENT DETAIL COMP-SHINGLE MOUNTING SURFACE: W-TILE1 SCALE: NTS ATTACHMENT DETAIL2 2.5" MIN. EMBEDMENT 5/16" LAG BOLT NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS TIERED RISE ROOF FRAMINGMODULE 6'-0" OC FOOT SPACING UNIRAC SM LIGHT RAIL UNIRAC W-TILE REPLACEMENT ATTACHMENT MASTIC TAPE 26 Sep 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY NOTE:LAG BOLT SHOULD HAVE 2.5" EMBEDDMENT INTO EXISTING 2X MEMBER NOTE TO INSTALLER: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY EOR IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND THE FOLLOWING: 2X4 TRUSSES @24" O.C. WITH TOP CHORD PANEL POINT DISTANCE EQUAL OR LESS THAN 8 FT. 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-3.1 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ATTACHMENT DETAIL ENLARGE VIEW2SCALE: NTS ATTACHMENT DETAIL1SCALE: NTS MASTIC TAPE RAFTERS/TRUSSES TIERED RISE 5/16" x 4" STAINLESS STEEL HEX HEAD LAG BOLTS ND W/2.5" MIN. EMBEDMENT SS EPDM BONDED WASHER (E) W-TILE ROOF ENLARGE VIEW PV MODULES 2"X4" TRUSS E S @ 24" O.C (E) W-TILE ROOF 1 0 " 1 . 3 8 PV MODULES ROOF / DECK MEMBRANE BUILDING STRUCTURE UNIRAC SM LIGHT RAIL L-FOOT ~1 0 " (E) W-TILE ROOF 1. 3 8 2.5" MIN. EMBEDMENT 26 Sep 2022 EXP : 30 Sep 2023 STRUCTURAL ONLY NOTE TO INSTALLER: VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY EOR IF THERE IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION AND THE FOLLOWING: 2X4 TRUSSES @24" O.C. WITH TOP CHORD PANEL POINT DISTANCE EQUAL OR LESS THAN 8 FT. 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-4 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION STRING LAYOUT STRING LAYOUT SCALE: 1/8" = 1'-0"1 (20) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES (20) SOLAREDGE S440 POWER OPTIMIZERS (02) STRINGS OF 10 MODULES CONNECTED IN SERIES PER STRING 33.696023, -116.303487 3' - 0 " 36" FIRE PATHWAY 18 " 18" FIRE PATHWAY 70.63" 41 . 1 9 " PHOTOVOLTAIC MODULES BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) CA L L E E S P E R A N Z A RE A R Y A R D FR O N T Y A R D ROOF #1 (4) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #2 (11) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #3 (5) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES ROOF #2 (11) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES STRING #1 STRING #2(20) SOLAREDGE S440 POWER OPTIMIZERS 36" FIRE PATHWAY 18 " F I R E P A T H W A Y 18 " F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY 18 " F I R E P A T H W A Y 18 " F I R E P A T H W A Y 36" FIRE PATHWAY 36 " F I R E P A T H W A Y 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-5 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ELECTRICAL LINE DIAGRAM ELECTRICAL LINE DIAGRAM SCALE: NTS1 #2 #1#10 #2 #1#10 10 MODULES CONNECTED IN STRING #1 10 MODULES CONNECTED IN STRING #2 (N)SOLAREDGE: SE6000H-USRGM, [240V] OUTPUT: 240 VAC,25A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT A B C D 1 2 3 DC AC (N)JUNCTION BOX G (N) AC DISCONNECT 60A NON FUSED, 240 VAC UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: IID 240V N/A (E) 200 A (E) 200 A NORTH SERVICE INFO. UNDERGROUND E 4 (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (TOP FED) L EXISTING GROUNDING SYSTEM (N) 35A PV BREAKER 200A 35A BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz CHANGE AS PER YOUR REQUIREMEN SYSTEM SIZE:- 20 x 370W = 7.40 kWDC SYSTEM SIZE:- 01 x 6000W / 1000 = 6.0 kWAC EQUIPMENT LEGEND ITEM DESCRIPTION A BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES B SOLAREDGE S440 POWER OPTIMIZERS C NEMA 3R JUNCTION BOX D SOLAREDGE SE6000H-USRGM, [240V] INVERTER E 60A NON FUSED AC DISCONNECT, NEMA 3R, UL LISTED, 240VAC INTERCONNECTION 120% RULE - CEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 200A x 120% = 240A SYSTEM SIZE:- 20 x 347.8 x 0.99 = 6.89 CEC kWAC SOLAREDGE S440 POWER OPTIMIZER RATED DC INPUT POWER - 440 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 14.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM SOLAREDGE OPTIMIZERS HAVE INTEGRATED RAPID SHUT DOWN TAG NO QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE 1 (4) (1) #10 AWG #6 AWG PV WIRE BARE CU GND FREE AIR N/A 2 (4) (1) #10 AWG #8 AWG THWN-2 THWN-2 GND EMT 3/4" 3 (3) (1) #8 AWG #8 AWG THWN THWN GND EMT 3/4" 4 (3) (1) #8 AWG #8 AWG THWN THWN GND EMT 3/4" (20) BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES (20) SOLAREDGE S440 POWER OPTIMIZERS (02) STRINGS OF 10 MODULES CONNECTED IN SERIES PER STRING 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-6 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ELECTRICAL CALCULATION ELECTRICAL CALCULATION SCALE: NTS1 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # BOVIET SOLAR BVM6610M-370S-H-HC-BF (370W) MODULES VMP 33.81 IMP 10.96 VOC 40.56 ISC 11.54 MODULE DIMENSION 70.63"L x 41.19"W x 1.38"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE SE6000H-USRGM, [240V] NOMINAL AC POWER 6.0KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 25A AMBIENT TEMPERATURE SPECS WEATHER STATION: PALM SPRINGS THERMAL AP RECORD LOW TEMP -5° AMBIENT TEMP (HIGH TEMP 2%)44° CONDUIT HEIGHT 0.9" ROOF TOP TEMP 44° CONDUCTOR TEMPERATURE RATE (ON ROOF)90° CONDUCTOR TEMPERATURE RATE (OFF ROOF)75° MODULE TEMPERATURE COEFFICIENT OF Voc -0.31%/°C OPTIMIZER SPECIFICATIONS POWER OPTIMIZER SOLAREDGE S440 DC INPUT POWER 440W PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: EXPECTED WIRE TEMP (In Celsius)44° TEMP. CORRECTION PER TABLE 310.15(B)(2)(a)0.87 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B) 18.75A 1.25 X MAX. DC OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(a) 27.84ATEMP. CORRECTION PER TABLE 310.15(B)(2)(a) X CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY RESULT SHOULD BE GREATER THAN (18.75A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY DC CONDUCTOR AMPACITY CALCULATIONS: JUNCTION BOX TO INVERTER: EXPECTED WIRE TEMP (In Celsius)44° TEMP. CORRECTION PER TABLE 310.15(B)(2)(a)0.87 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B) 18.75A 1.25 X MAX. DC OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(a) 27.84ATEMP. CORRECTION PER TABLE 310.15(B)(2)(a) X CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY RESULT SHOULD BE GREATER THAN (18.75A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY AC CONDUCTOR AMPACITY CALCULATIONS: INVERTER TO INTERCONNECTION: EXPECTED WIRE TEMP (In Celsius)44° TEMP. CORRECTION PER TABLE 310.15(B)(2)(a)0.82 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)1.00 CIRCUIT CONDUCTOR SIZE 8AWG CIRCUIT CONDUCTOR AMPACITY 50A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(B) 31.25A 1.25 X INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(a) 41.00ATEMP. CORRECTION PER TABLE 310.15(B)(2)(a) X CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY RESULT SHOULD BE GREATER THAN (31.25A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-7 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION WARNING LABELS & PLACARD DC DISCONNECT / RAPID SHUTDOWN SYSTEM IFC 605.11.3.1(2) & 690.56(C)(1)(b) LABEL LOCATION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT. SOLAR ELECTRIC PV PANELS WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: AC DISCONNECT & INVERTER (PER CODE: CEC 690.13(B) AND 690.54) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 25 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING (PER CODE: [CEC 705.12(B)(2)(3)(B)]) LABEL LOCATION: AC & DC DISCONNECT AND SUB PANEL (PER CODE: CEC 690.13(B)) WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: [CEC 690.31(G)(3)] LABEL LOCATION: AC & DC DISCONNECT AND SUB PANEL (PER CODE: CEC 690.41(B)) TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING ELECTRIC SHOCK HAZARD ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: RAPID SHUTDOWN (PER CODE: CEC 690.56(C)(3)LABEL LOCATION: MAIN SERVICE PANEL & NET METER (PER CODE: [CEC 705.12(D)(3)] WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! LABEL LOCATION: INVERTER (PER CODE: CEC 690.31(I) LABEL LOCATION: MSP (PER CODE: CEC 705.12(B)(3)) CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: [CEC 690.13(B)]) ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! LABEL LOCATION: AC DISCONNECT/BREAKER/ POINT OF CONNECTION (PER CODE: CEC 690.13(B) PHOTOVOLTAIC AC DISCONNECT AT RAPID SHUTDOWN SYSTEM [IFC 605.11.3.1(1) & 690.56(C)(1)(a)] LABEL LOCATION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. CEC 2019 MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 480 16.5 15 LABEL LOCATION: DC DISCONNECT, (PER CODE: CEC 690.53) CAUTION ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT:MAIN SERVICE PANEL, UTILITY METER,INVERTER, AC DISCONNECT 48 6 1 5 CA L L E E S P E R A N Z A PV MODULES INVERTER UTILITY METER MAIN SERVICE PANEL AC DISCONNECT 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-8 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION ADDITIONAL NOTES 1.EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 3.AC / DC SOLAR FED CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED PER CEC690.31(G)(3) 4.EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5.CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6.OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. 7.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC. 8.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, PV WIRING MUST BE SECURED AND PROPERLY MANAGED, NOT IN CONTACT WITH ROOF SURFACE. CEC 110.2 - 110.4 / 300.4. WIRE IN CONDUIT NEEDS TO BE MOUNTED > 3.5IN ABOVE ROOF SURFACE TO MAINTAIN TEMPERATURE DERATE VALUES 09/27/2022 REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-9 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 POWER OPTIMIZER CHART 33.696023, -116.303487 OPTIMIZER CHART CA L L E E S P E R A N Z A REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-10 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-11 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-12 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-13 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-14 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-15 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-16 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-17 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-18 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-19 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-20 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS REVDATEDESCRIPTION VERSION UR08/09/2022INITIAL RELEASE KUUBIX GLOBAL LLC 7401 W SUNNYVIEW AVE, VISALIA, CA 93291 TEL: (855) 458-8249 C-10 LICENSE NO#1077074 Website : www.kuubixenergy.com CONTRACTOR SIGNATURE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-21 PROJECT NAME UR08/09/2022INITIAL RELEASE MO N A D A V I D S O N 48 6 1 5 CA L L E E S P E R A N Z A , LA Q U I N T A , CA 9 2 2 5 3 , US A AP N # 64 6 1 2 1 0 0 8 UT I L I T Y : II D AH J : CI T Y O F L A Q U I N T A SHEET SIZE ANSI B 11" X 17" A09/23/2022REVISION SPEC SHEETS