Loading...
Estates at Point Happy TR 31348 BCPR2024-0002 Solar Master Plans (Plan 1, 1X, & 2)SOLAR MASTER PLAN PERMIT PACKAGE WILLIAMS HOMES 21080 CENTRE POINTE PARKWAYSANTA CLARITA, CA 91350 TRACT / PARCEL #: 31348LA QUINTA, CALIFORNIA 92253 POINT HAPPY PLAN 1 (2762), 1X (2762) & 2 (3213) CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S T ATE OF CA L I F O R NIA CHI F UNG L E UN G PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® VICINITY MAP PROJECT LOCATION SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B R E V I S I O N S GENERAL NOTES: SHEET INDEX SOLAR ARCHITECTURAL DRAWINGS SOLAR STRUCTURAL DRAWINGS PVA-0 COVER SHEET PVA-1 PLAN 1 (2762) ELEVATION A, B PVA-2 PVA-3 PLAN 1X (2762) ELEVATION B PLAN 2 (3213) ELEVATION A, B SOLAR ELECTRICAL DRAWINGS PVE-1 PVE-2 PVE-3 ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONS PVE-4 ELECTRICAL DETAILS EQUIPMENT ELEVATION & PLACARD ELECTRICAL DATA & SPECIFICATIONS PVS-1 PVS-3 MOUNTING DETAILS STRUCTURAL CALCULATIONSPVS-2 MOUNTING DETAILS, STRUCTURAL INFORMATION & SPECIFICATIONS PVA-0 SCOPE OF WORK: INSTALLATION OF 10KWH ENERGY STORAGE FOR A 6.08KW SOLAR PHOTOVOLTAIC SYSTEM IN NEW HOMES SINGLE FAMILY DWELLING UNIT THAT INCLUDES PV MODULES WITH MICROINVERTER. ESS TO BE PROTECTED BY HEAT ALARMS COMPLYING WITH R314 (BY OTHERS) ALL HEAT PRODUCING VENTS FROM OTHER EQUIPMENT SHALL BE NO CLOSER THAN 1FT OR FIRE CODE SETBACK MINIMUM WHICHEVER IS GREATER. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, GREEN BUILDING AND ENERGY CODES AND THE LA QUINTA MUNICIPAL CODE. ENERGY STORAGE SYSTEM UP D A T E D T O 1 0 k w h E N P H A S E E S S 1 2 / 1 4 / 2 3 J F PVE-5 ELECTRICAL DATA & SPECIFICATIONS PVE-6 ELECTRICAL DATA & SPECIFICATIONS UP D A T E D T O 2 0 1 9 C O D E 0 1 / 1 5 / 2 4 R V I UP D A T E D T O 2 0 2 2 C O D E & U P D A T E D S H E E T I N D E X 03 / 2 0 / 2 4 R V I UP D A T E D N O T E S A S P E R A H J C O M M E N T S 05 / 2 0 / 2 4 R V I BCPR2024-0002 POINT HAPPY / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLAN TYPES 1, 2 & 2X FOR THE 2022 CODE CYCLE. INDIVIDUAL PERMITS TO BE ISSUED FOR EACH ADDRESS. 2022 CALIFORNIA BUILDING CODES. ALL PLAN TYPES: 6.08kW SOLAR ARRAY w/ 10kWh E.S.S. - (15) 405W Q.PEAK DUO BLK ML-G10+ MODULES W/ IQ7HS-66-M-US MICROINVERTERS + ENPHASE IQ COMBINER 5C PANEL, (2) 5kWh ENPHASE 5P BATTERIES + IQ SYSTEM CONTROLLER 3 [300SF]. SOLAR ARRAY TO BE ORIENTED BETWEEN 105°-300° AZIMUTH. 06/25/2024 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA C H I F U N G L E U N G SO L A R M A S T E R P L A N P E R M I T P A C K A G E PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 1 (2762) - ELEVATION A - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2762 SQ. FT. NUMBER OF STORIES: 1-STORY HANWHA 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 15 6.08 kW LAYOUT 1 LAYOUT 2 LAYOUT 3 PLAN 1 (2762) - ELEVATION B - S-TILE LAYOUT 1 LAYOUT 2 LAYOUT 3 LEFT FRONT OF HOUSE : 15° - 210° LEFT FRONT OF HOUSE : 15° - 210° RIGHT FRONT OF HOUSE : 195° - 30°BACK FRONT OF HOUSE : 285° - 120° RIGHT FRONT OF HOUSE : 195° - 30°BACK FRONT OF HOUSE : 285° - 120° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) TRANSITION BOX ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT LEGENDS: FIRE ACCESS PATHWAY IQ BATTERY 5P (INT) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) IQ BATTERY 5P (INT)IQ BATTERY 5P (INT) IQ BATTERY 5P (INT)IQ BATTERY 5P (INT) IQ BATTERY 5P (INT) TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® PVA-1 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PL A N 1 ( 2 7 6 2 ) E L E V A T I O N A & B AD D E D E N P H A S E E S S 1 1 / 1 6 / 2 3 A R UP D A T E D S Y S T E M S I Z E F R O M 6 . 4 8 K W T O 6 . 0 8 K W 12 / 0 4 / 2 3 I D G AD D E D E S S O P T I O N 0 9 / 1 0 / 2 3 J A R RE L O C A T E D B A T T E R I E S & A D D E D E S S A C D 3/ 1 9 / 2 4 R V I 5/ 2 0 / 2 4 R V I UP D A T E D E Q U I P M E N T T A G G I N G 06/25/2024 PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 1X (2762) - ELEVATION B - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2762 SQ. FT. NUMBER OF STORIES: 1-STORY HANWHA 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 15 6.08 kW LAYOUT 1 LAYOUT 2LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINTROOF ACCESS POINT LAYOUT 1 BACK FRONT OF HOUSE : 285° - 120° ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) LEGENDS: FIRE ACCESS PATHWAY IQ BATTERY 5P (INT)IQ BATTERY 5P (INT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) IQ BATTERY 5P (INT) E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA C H I F U N G L E U N G SO L A R M A S T E R P L A N P E R M I T P A C K A G E PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-2 PL A N 1 X ( 2 7 6 2 ) E L E V A T I O N B 3/ 1 9 / 2 4 R V I AD D E D P L A N 1 X 5/ 2 0 / 2 4 R V I UP D A T E D E Q U I P M E N T T A G G I N G 06/25/2024 PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 2 (3213) - ELEVATION A - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 3213 SQ. FT. NUMBER OF STORIES: 1-STORY HANWHA 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 15 6.08 kW LAYOUT 1 LAYOUT 2 PLAN 2 (3213) - ELEVATION B - S-TILE LAYOUT 1 LAYOUT 2 LEFT FRONT OF HOUSE : 15° - 210° LEFT FRONT OF HOUSE : 15° - 210° RIGHT FRONT OF HOUSE : 195° - 30° RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT LEGENDS: FIRE ACCESS PATHWAY ROOF ACCESS POINT TRANSITION BOX IQ BATTERY 5P (INT) IQ BATTERY 5P (INT)IQ BATTERY 5P (INT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT)IQ BATTERY 5P (INT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) (E) SERVICE POINT AND UTILITY METERING (EXT) BACK-UP LOAD CENTER (BY OTHERS) (INT) IQ SYSTEM CONTROLLER AND ESS DISCONNECTING MEANS (INT) IQ COMBINER (INT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) ESS AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (EXT) E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA C H I F U N G L E U N G SO L A R M A S T E R P L A N P E R M I T P A C K A G E PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-3 PL A N 2 ( 3 2 1 3 ) E L E V A T I O N A & B AD D E D E N P H A S E E S S 1 1 / 1 6 / 2 3 A R UP D A T E D S Y S T E M S I Z E F R O M 6 . 4 8 K W T O 6 . 0 8 K W 12 / 0 4 / 2 3 I D G AD D E D E S S O P T I O N 0 9 / 1 0 / 2 3 J A R RE L O C A T E D B A T T E R I E S & A D D E D E S S A C D 3/ 1 9 / 2 4 R V I 5/ 2 0 / 2 4 R V I UP D A T E D E Q U I P M E N T T A G G I N G 06/25/2024 PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-1 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® 06/25/2024 PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® 06/25/2024 02 8 1 7 , 1 *  ' ( 7 $ , / 6   6 7 5 8 & 7 8 5 $ /  , 1 ) 2 5 0 $ 7 , 2 1    6 3 ( & , ) , & $ 7 , 2 1 6 PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-3 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® 06/25/2024 NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 FFFF CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --A B TAG SINGLE LINE DIAGRAM - (N) 10 kWH ENERGY STORAGE SYSTEM & PHOTOVOLTAIC SYSTEM TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX SEPARATE AC DISCONNECT DESCRIPTION PV MODULE / BRANCH 3 4 BACK-UP LOAD CENTER ENPHASE IQ 5P BATTERY6 WITH EGC 6.08 kWDC 2 A DC AC DC AC 1 SOLAR CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B BRANCH CIRCUIT #2 BRANCH CIRCUIT #1 #10 #10 ATTIC ROOFTOP #6 (E) MAIN SERVICE PANEL 225A,120/240V,1PH,3W 6ENPHASE IQ COMBINER 5C MODEL: X-IQ-AM1-240-5C UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB GND EXISTING GND GND 200A, 2P SER, CU -- 1 3C #4 #2 1 2D#10 #8 SER CU EGC CU EGC BARE CU CU-NM-B NON CRITICAL LOADS 20A, 2P 20A, 2P CAT5e SUNPOWER MONITORING PVS6 (2) 5 kWh, 3.84 kW BATTERY ENPHASE 5P BATTERY MODEL: IQBATTERY-5P-1P-NA PCT Q.PEAK DUO BLK ML-G10+ (405) IQ7HS-66-M-US (240) #10 #14#14 #14 NM CABLE OR EQ INSTALLED IN WALL CAVITY CU-NM-B EGC BARE CU -- 3 1 3E AC DC 5 kWh IQ Battery AC DC NM CABLE OR EQ INSTALLED IN WALL CAVITY -- 15A, 2P IQ GATEWAY MI D MLO MIDC 40A, 2P 30A, 2P GND (E) BACK UP LOAD CENTER 100A MIN OR EQUIVALENT, 120/240 V, 1PH M.L.O, NEMA-3R 7 NOTE: INSTALLED BY OTHERS TO LOADS INCLUDED IN BACK-UP GND CCT (3) #22 AWG TWISTED PAIR GND IQ SYSTEM CONTROLLER 3 MODEL: SC200D111C240US01 NFT ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. 70A, 2P N 3 GND 45 ENPHASE IQ COMBINER 5C ENPHASE IQ SYSTEM CONTROLLER 3 CU-NM-B EGC BARE CU #10 1 -- 60A, 2P NM CABLE OR EQ INSTALLED ALONG RACEWAY 15A, 2P E --G #12 2CU-NM-B C D 5 kWh IQ Battery GND 7 ADDITIONAL ELECTRICAL NOTES 1. SINGLE PRODUCTION CT INCLUDES L1 CONDUCTORS ONLY. 2. TWO BRANCH CIRCUITS OF IQ7 MICROINVERTERS. 3. INDICATES NEMA 3R RATING. 4. GENERATOR INPUT NOT CURRENTLY SUPPORTED. 5. NON-ESSENTIAL LOADS INCLUDE A 120A INSTANT ON-DEMAND ELECTRIC WATER HEATER. 6. EACH PV BRANCH CIRCUIT HAS AN OCPD BREAKER SIZE OF 20A, 2-POLE. 7. CONSUMPTION CTS MEASURE CONSUMPTION ON ALL LOADS AT SITE F SUNPOWER PROVIDED ENGAGE CABLES NM CABLE OR EQ INSTALLED IN WALL CAVITY G MICROINVERTER HANWHA MODULES ENPHASE CAN BUS CABLE ENPHASE CAN BUS CABLE 40/15 2P QUAD 8 MODULES 7 MODULES C GND3 EATON DG223URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES UTILITY-LOCKABLE SAFETY SWITCH 100A, 240VAC EATON DG222URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC D 3 GND UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT ESS AC DISCONNECT WITHIN LINE OF SIGHT OF THE MAIN SERVICE PANEL ESS BREAKER AS DISCONNECTING MEANS, INSTALLED IN ACCORDANCE WITH 706.15 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S T ATE OF CA L I F O R NIA CHI F UNG L E UN G PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1 UP D A T E D T O 1 0 k w h E N P H A S E E S S 1 2 / 1 4 / 2 3 J F UP D A T E D A C D & S Y S T E M S I Z E T O 6 . 0 8 K W 01 / 0 3 / 2 4 J F UP D A T E D C O N D U C T O R F O R T A G C 01 / 1 5 / 2 4 R V I AD D E D E S S A C D I S C O N N E C T 03 / 2 0 / 2 4 R V I 05 / 2 0 / 2 4 R V I UP D A T E D A S P E R A H J C O M M E N T 06/25/2024 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S T ATE OF CA L I F O R NIA CHI F UNG L E UN G PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® GARAGE FLOOR CONCRETE CURB PVS6 PVS6 MONITORING HEAT DETECTOR (BY OTHERS) IQ SYSTEM CONTROLLER ENPHASE IQ SYSTEM CONTROLLER ENPHASE IQ COMBINER ENPHASE IQ COMBINER ENPHASE IQ BATTERY ENPHASE IQ BATTERY SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EQ U I P M E N T E L E V A T I O N & P L A C A R D PVE-2 DRIVEWAY TYPICAL ESS DIRECTORY PLACARD NOTE: CUSTOMIZED PLACARD WILL BE PROVIDED FOR EACH LOT(UNIT) N SERVICE BREAKER BATTERY SWITCH POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION: PHOTOVOLTAIC AC DISCONNECT (EXT) PHOTOVOLTAICARRAY ON ROOF (1 OF 2) MAIN SERVICE PANEL (EXT) YOU ARE HERE BATTERY STORAGE (INT) IQ SYSTEMCONTROLLER (INT) IQ COMBINER (INT) DRIVEWAY N PHOTOVOLTAIC AC DISCONNECT (EXT) PHOTOVOLTAICARRAY ON ROOF MAIN SERVICE PANEL (EXT) (1 OF 2) BATTERY STORAGE (INT) YOU ARE HERE IQ SYSTEMCONTROLLER (INT) IQ COMBINER (INT) UP D A T E D T O 1 0 k w h E N P H A S E E S S 1 2 / 1 4 / 2 3 J F UP D A T E D S Y S T E M S I Z E T O 6 . 0 8 K W 01 / 1 5 / 2 4 R V I RE L O C A T E D E S S B A T T E R Y 03 / 2 0 / 2 4 R V I PHOTOVOLTAIC AC DISCONNECT (EXT) ESS AC DISCONNECT (EXT) PHOTOVOLTAIC AC DISCONNECT (EXT) ESS AC DISCONNECT (EXT) IN C L U D E D E S S D I S C O N N E C T O N P L A C A R D 04 / 1 5 / 2 4 R V I 06/25/2024 FIGURE 1: ELECTRICAL SIGNAGES/STICKERS WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE x x x TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM x x x FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION x x POWER SUPPLY SOURCES WARNING UTILITY GRID PV ELECTRICAL SYSTEM WARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION AC SOLAR DISCONNECT x ENERGY STORAGE SYSTEM CONTAINS ENERGIZED BATTERIES SIGNAGE LOCATIONS: x ENPHASE ENERGY STORAGE SYSTEM x x x PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: 24.00 240 24.00 240 6.08 kW 6.08 kW UTILITY PV SYSTEM DISCONNECT SAFETY SWITCH FOR UTILITY OPERATION AC DISCONNECT SIGNAGE LOCATIONS: x INDOOR / OUTDOOR AC DISCONNECT !! WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE SIGNAGE LOCATIONS: x MAIN SERVICE PANEL x PANEL ENCLOSURE INTERIOR x x !WARNING TURN OFF UTILITY DG AC SAFETY DISCONNECT PRIOR TO WORKING IN METER SERVICE PANEL SOLAR PV BREAKER SIGNAGE LOCATIONS: x MAIN SERVICE PANEL x PANEL ENCLOSURE INTERIOR BREAKER IS BACKFED DO NOT RELOCATE ENERGY STORAGE SYSTEM DISCONNECT x x ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: 120/240 VAC 60 HZ 86.4V E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S T ATEOF CA L I F O R NIA CHI F UNG L E UN G PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D E T A I L S PVE-3 UP D A T E D T O 1 0 k w h E N P H A S E E S S 1 2 / 1 4 / 2 3 J F UP D A T E D S Y S T E M S I Z E T O 6 . 0 8 K W 01 / 1 5 / 2 4 R V I AD D E D E S S D I S C O N N E C T S I G N A G E 03 / 2 0 / 2 4 R V I AD D E D N E C E S S A R Y E S S S I G N A G E 04 / 1 5 / 2 4 R V I 06/25/2024 CURRENT TRANSFORMER SPECIFICATION SHEET PVS6 DATASHEET 1 PVS6 DATASHEET 2 PVS6 INSTALLATION INSTRUCTIONS 2PVS6 INSTALLATION INSTRUCTIONS 1 Q-CABLE DATA SHEET 1/2 Q-CABLE DATA SHEET 2/2 ENPHASE DATA SHEET 1/2 ENPHASE DATA SHEET 2/2 CONDUCTOR AND OCP SIZING TABLE CLASS A FIRE RATING LISTING PG 1/3 CLASS A FIRE RATING LISTING PG 2/3 CLASS A FIRE RATING LISTING PG 3/3 PV MODULE SPECIFICATION SHEET 1/2 PV MODULE SPECIFICATION SHEET 2/2 RAIL-MOUNTED JUNCTION BOX 1/2 RAIL-MOUNTED JUNCTION BOX 2/2UNIVERSAL INVISIMOUNT INSTALLATION GUIDE PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHI F UNG L E UN G SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D A T A & S P E C I F I C A T I O N S PVE-4 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG AC DISCONNECT DATA SHEET ALUMINUM SERVICE ENTRANCE CABLE SHEET 1/2 ALUMINUM SERVICE ENTRANCE CABLE SHEET 2/2 INVISIMOUNT DATA SHEET ENPHASE IQ SYSTEM CONTROLLER DATASHEET 1/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 2/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 3/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 4/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 5/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 6/6 ENPHASE IQ COMBINER DATASHEET 1/4 ENPHASE IQ COMBINER DATASHEET 2/4 ENPHASE IQ COMBINER DATASHEET 3/4 ENPHASE IQ COMBINER DATASHEET 4/4 ENPHASE IQ BATTERY 5P DATASHEET 1/3 ENPHASE IQ BATTERY 5P DATASHEET 2/3 ENPHASE IQ BATTERY 5P DATASHEET 3/3 PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHI F UNG L E UN G SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D A T A & S P E C I F I C A T I O N S PVE-5 SHEET UP D A T E D T O 1 0 k w h E N P H A S E E S S 1 2 / 1 4 / 2 3 J F TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG HEAT DETECTOR HEAT DETECTOR PG 1/4 HEAT DETECTOR PG 2/4 HEAT DETECTOR PG 3/4 HEAT DETECTOR PG 4/4 PO I N T H A P P Y TR A C T / P A R C E L # : 3 1 3 4 8 WI L L I A M S H O M E S 21 0 8 0 C E N T R E P O I N T E P A R K W A Y LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SA N T A C L A R I T A , C A 9 1 3 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 88 0 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHI F UNG L E UN G SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D A T A & S P E C I F I C A T I O N S PVE-6 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C003130 D-0129758 2024-05-20 VON INCIONG