Estates at Point Happy TR 31348 BCPR2024-0002 Solar Master Plans (Plan 1, 1X, & 2)SOLAR MASTER PLAN PERMIT PACKAGE
WILLIAMS HOMES
21080 CENTRE POINTE PARKWAYSANTA CLARITA, CA 91350
TRACT / PARCEL #: 31348LA QUINTA, CALIFORNIA 92253
POINT HAPPY
PLAN 1 (2762), 1X (2762) & 2 (3213)
CODE INFORMATION
APPLICABLE CODES, LAWS AND REGULATIONS
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA RESIDENTIAL CODE (CRC)
2022 CALIFORNIA FIRE CODE (CFC)
2022 CALIFORNIA ELECTRICAL CODE (CEC)
2022 CALIFORNIA MECHANICAL CODE (CMC)
2022 CALIFORNIA PLUMBING CODE (CPC)
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
EER
S
T
ATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
VICINITY MAP
PROJECT LOCATION
SHEET
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
GENERAL NOTES: SHEET INDEX
SOLAR ARCHITECTURAL DRAWINGS
SOLAR STRUCTURAL DRAWINGS
PVA-0 COVER SHEET
PVA-1 PLAN 1 (2762) ELEVATION A, B
PVA-2
PVA-3
PLAN 1X (2762) ELEVATION B
PLAN 2 (3213) ELEVATION A, B
SOLAR ELECTRICAL DRAWINGS
PVE-1
PVE-2
PVE-3
ELECTRICAL SINGLE LINE DIAGRAM & SPECIFICATIONS
PVE-4
ELECTRICAL DETAILS
EQUIPMENT ELEVATION & PLACARD
ELECTRICAL DATA & SPECIFICATIONS
PVS-1
PVS-3
MOUNTING DETAILS
STRUCTURAL CALCULATIONSPVS-2
MOUNTING DETAILS, STRUCTURAL INFORMATION & SPECIFICATIONS
PVA-0
SCOPE OF WORK:
INSTALLATION OF 10KWH ENERGY STORAGE FOR A 6.08KW SOLAR PHOTOVOLTAIC SYSTEM IN NEW HOMES SINGLE FAMILY DWELLING UNIT THAT INCLUDES PV MODULES WITH MICROINVERTER.
ESS TO BE PROTECTED BY HEAT ALARMS COMPLYING WITH R314 (BY OTHERS)
ALL HEAT PRODUCING VENTS FROM OTHER EQUIPMENT SHALL BE NO CLOSER THAN 1FT OR FIRE CODE SETBACK MINIMUM WHICHEVER IS GREATER.
ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, GREEN BUILDING AND ENERGY CODES AND THE LA QUINTA
MUNICIPAL CODE.
ENERGY STORAGE SYSTEM
UP
D
A
T
E
D
T
O
1
0
k
w
h
E
N
P
H
A
S
E
E
S
S
1
2
/
1
4
/
2
3
J
F
PVE-5 ELECTRICAL DATA & SPECIFICATIONS
PVE-6 ELECTRICAL DATA & SPECIFICATIONS
UP
D
A
T
E
D
T
O
2
0
1
9
C
O
D
E
0
1
/
1
5
/
2
4
R
V
I
UP
D
A
T
E
D
T
O
2
0
2
2
C
O
D
E
&
U
P
D
A
T
E
D
S
H
E
E
T
I
N
D
E
X
03
/
2
0
/
2
4
R
V
I
UP
D
A
T
E
D
N
O
T
E
S
A
S
P
E
R
A
H
J
C
O
M
M
E
N
T
S
05
/
2
0
/
2
4
R
V
I
BCPR2024-0002
POINT HAPPY / SOLAR PHOTOVOLTAIC
MASTER PLANS FOR PLAN TYPES 1, 2 & 2X
FOR THE 2022 CODE CYCLE. INDIVIDUAL
PERMITS TO BE ISSUED FOR EACH
ADDRESS. 2022 CALIFORNIA BUILDING
CODES.
ALL PLAN TYPES: 6.08kW SOLAR ARRAY w/
10kWh E.S.S. - (15) 405W Q.PEAK DUO BLK
ML-G10+ MODULES W/ IQ7HS-66-M-US
MICROINVERTERS + ENPHASE IQ
COMBINER 5C PANEL, (2) 5kWh ENPHASE
5P BATTERIES + IQ SYSTEM CONTROLLER
3 [300SF]. SOLAR ARRAY TO BE ORIENTED
BETWEEN 105°-300° AZIMUTH.
06/25/2024
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
EER
S
TATE OF CA L I F O R NIA
C
H
I
F
U
N G
L
E
U
N
G
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
PLAN 1 (2762) - ELEVATION A - S-TILE
NOTE :
- ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
- FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT,
MECHANICAL VENT.
BASE SQUARE FOOTAGE: 2762 SQ. FT.
NUMBER OF STORIES: 1-STORY
HANWHA 132 CELLS AC MODULES
MODEL NO.NOMINAL POWER (Pnom)
405W
SYSTEM SIZE
Q.PEAK DUO BLK ML-G10+ (405)
QUANTITY: 15
6.08 kW
LAYOUT 1 LAYOUT 2 LAYOUT 3
PLAN 1 (2762) - ELEVATION B - S-TILE
LAYOUT 1 LAYOUT 2 LAYOUT 3
LEFT FRONT OF HOUSE : 15° - 210°
LEFT FRONT OF HOUSE : 15° - 210°
RIGHT FRONT OF HOUSE : 195° - 30°BACK FRONT OF HOUSE : 285° - 120°
RIGHT FRONT OF HOUSE : 195° - 30°BACK FRONT OF HOUSE : 285° - 120°
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
TRANSITION BOX
ROOF ACCESS POINT
TRANSITION BOX
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX
ROOF ACCESS POINT
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT
LEGENDS:
FIRE ACCESS PATHWAY
IQ BATTERY 5P (INT)
ROOF ACCESS POINT
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
IQ BATTERY 5P (INT)IQ BATTERY 5P (INT)
IQ BATTERY 5P (INT)IQ BATTERY 5P (INT)
IQ BATTERY 5P (INT)
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
PVA-1
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PL
A
N
1
(
2
7
6
2
)
E
L
E
V
A
T
I
O
N
A
&
B
AD
D
E
D
E
N
P
H
A
S
E
E
S
S
1
1
/
1
6
/
2
3
A
R
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
F
R
O
M
6
.
4
8
K
W
T
O
6
.
0
8
K
W
12
/
0
4
/
2
3
I
D
G
AD
D
E
D
E
S
S
O
P
T
I
O
N
0
9
/
1
0
/
2
3
J
A
R
RE
L
O
C
A
T
E
D
B
A
T
T
E
R
I
E
S
&
A
D
D
E
D
E
S
S
A
C
D
3/
1
9
/
2
4
R
V
I
5/
2
0
/
2
4
R
V
I
UP
D
A
T
E
D
E
Q
U
I
P
M
E
N
T
T
A
G
G
I
N
G
06/25/2024
PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
PLAN 1X (2762) - ELEVATION B - S-TILE
NOTE :
- ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
- FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT,
MECHANICAL VENT.
BASE SQUARE FOOTAGE: 2762 SQ. FT.
NUMBER OF STORIES: 1-STORY
HANWHA 132 CELLS AC MODULES
MODEL NO.NOMINAL POWER (Pnom)
405W
SYSTEM SIZE
Q.PEAK DUO BLK ML-G10+ (405)
QUANTITY: 15
6.08 kW
LAYOUT 1 LAYOUT 2LEFTFRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30°
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
ROOF ACCESS POINT
TRANSITION BOX
ROOF ACCESS POINT
TRANSITION BOX
ROOF ACCESS POINTROOF ACCESS POINT
LAYOUT 1 BACK FRONT OF HOUSE : 285° - 120°
ROOF ACCESS POINT
TRANSITION BOX
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
LEGENDS:
FIRE ACCESS PATHWAY
IQ BATTERY 5P (INT)IQ BATTERY 5P (INT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
IQ BATTERY 5P (INT)
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
EER
S
TATE OF CA L I F O R NIA
C
H
I
F
U
N G
L
E
U
N
G
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PVA-2
PL
A
N
1
X
(
2
7
6
2
)
E
L
E
V
A
T
I
O
N
B
3/
1
9
/
2
4
R
V
I
AD
D
E
D
P
L
A
N
1
X
5/
2
0
/
2
4
R
V
I
UP
D
A
T
E
D
E
Q
U
I
P
M
E
N
T
T
A
G
G
I
N
G
06/25/2024
PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
PLAN 2 (3213) - ELEVATION A - S-TILE
NOTE :
- ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
- FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT,
MECHANICAL VENT.
BASE SQUARE FOOTAGE: 3213 SQ. FT.
NUMBER OF STORIES: 1-STORY
HANWHA 132 CELLS AC MODULES
MODEL NO.NOMINAL POWER (Pnom)
405W
SYSTEM SIZE
Q.PEAK DUO BLK ML-G10+ (405)
QUANTITY: 15
6.08 kW
LAYOUT 1 LAYOUT 2
PLAN 2 (3213) - ELEVATION B - S-TILE
LAYOUT 1 LAYOUT 2
LEFT FRONT OF HOUSE : 15° - 210°
LEFT FRONT OF HOUSE : 15° - 210°
RIGHT FRONT OF HOUSE : 195° - 30°
RIGHT FRONT OF HOUSE : 195° - 30°
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
ROOF ACCESS POINT
TRANSITION BOX
ROOF ACCESS POINT
TRANSITION BOX
TRANSITION BOX
ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT
LEGENDS:
FIRE ACCESS PATHWAY
ROOF ACCESS POINT
TRANSITION BOX
IQ BATTERY 5P (INT)
IQ BATTERY 5P (INT)IQ BATTERY 5P (INT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)IQ BATTERY 5P (INT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
(E) SERVICE POINT AND
UTILITY METERING (EXT)
BACK-UP LOAD CENTER
(BY OTHERS) (INT)
IQ SYSTEM CONTROLLER AND ESS
DISCONNECTING MEANS (INT)
IQ COMBINER (INT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
ESS AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL) (EXT)
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
EER
S
TATE OF CA L I F O R NIA
C
H
I
F
U
N G
L
E
U
N
G
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PVA-3
PL
A
N
2
(
3
2
1
3
)
E
L
E
V
A
T
I
O
N
A
&
B
AD
D
E
D
E
N
P
H
A
S
E
E
S
S
1
1
/
1
6
/
2
3
A
R
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
F
R
O
M
6
.
4
8
K
W
T
O
6
.
0
8
K
W
12
/
0
4
/
2
3
I
D
G
AD
D
E
D
E
S
S
O
P
T
I
O
N
0
9
/
1
0
/
2
3
J
A
R
RE
L
O
C
A
T
E
D
B
A
T
T
E
R
I
E
S
&
A
D
D
E
D
E
S
S
A
C
D
3/
1
9
/
2
4
R
V
I
5/
2
0
/
2
4
R
V
I
UP
D
A
T
E
D
E
Q
U
I
P
M
E
N
T
T
A
G
G
I
N
G
06/25/2024
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PVS-1
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
06/25/2024
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PVS-2
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
06/25/2024
02
8
1
7
,
1
*
'
(
7
$
,
/
6
6
7
5
8
&
7
8
5
$
/
,
1
)
2
5
0
$
7
,
2
1
6
3
(
&
,
)
,
&
$
7
,
2
1
6
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PVS-3
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
06/25/2024
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
FFFF
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --A
B
TAG
SINGLE LINE DIAGRAM - (N) 10 kWH ENERGY STORAGE SYSTEM & PHOTOVOLTAIC SYSTEM
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
SEPARATE AC DISCONNECT
DESCRIPTION
PV MODULE / BRANCH
3
4
BACK-UP LOAD CENTER
ENPHASE IQ 5P BATTERY6
WITH EGC
6.08 kWDC
2
A
DC
AC
DC
AC
1
SOLAR CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
B
BRANCH CIRCUIT #2
BRANCH CIRCUIT #1
#10
#10
ATTIC
ROOFTOP
#6
(E) MAIN SERVICE PANEL
225A,120/240V,1PH,3W
6ENPHASE IQ COMBINER 5C
MODEL: X-IQ-AM1-240-5C
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
GND
EXISTING
GND
GND
200A, 2P
SER, CU --
1
3C
#4
#2
1
2D#10
#8
SER CU
EGC CU
EGC BARE CU
CU-NM-B
NON CRITICAL
LOADS
20A, 2P
20A, 2P
CAT5e
SUNPOWER
MONITORING
PVS6
(2) 5 kWh, 3.84 kW BATTERY
ENPHASE 5P BATTERY
MODEL: IQBATTERY-5P-1P-NA
PCT
Q.PEAK DUO BLK ML-G10+ (405)
IQ7HS-66-M-US (240)
#10
#14#14
#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
CU-NM-B
EGC BARE CU --
3
1
3E
AC
DC
5 kWh
IQ Battery
AC
DC
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --
15A, 2P
IQ GATEWAY
MI
D
MLO
MIDC
40A, 2P
30A, 2P
GND
(E) BACK UP LOAD CENTER
100A MIN OR EQUIVALENT, 120/240 V, 1PH
M.L.O, NEMA-3R
7
NOTE: INSTALLED BY OTHERS
TO LOADS INCLUDED
IN BACK-UP
GND
CCT
(3) #22 AWG TWISTED PAIR
GND
IQ SYSTEM CONTROLLER 3
MODEL: SC200D111C240US01
NFT
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND
AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR
GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS
AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN
OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED
APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS,
ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE
INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY
REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER
CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A
THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE
UPSIZE.
13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE.
14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE
TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP
15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED.
70A, 2P
N
3
GND
45
ENPHASE IQ COMBINER 5C
ENPHASE IQ SYSTEM CONTROLLER 3
CU-NM-B
EGC BARE CU #10 1
--
60A, 2P
NM CABLE OR EQ
INSTALLED ALONG RACEWAY
15A, 2P
E
--G #12 2CU-NM-B
C
D
5 kWh
IQ Battery
GND
7
ADDITIONAL ELECTRICAL NOTES
1. SINGLE PRODUCTION CT INCLUDES L1 CONDUCTORS ONLY.
2. TWO BRANCH CIRCUITS OF IQ7 MICROINVERTERS.
3. INDICATES NEMA 3R RATING.
4. GENERATOR INPUT NOT CURRENTLY SUPPORTED.
5. NON-ESSENTIAL LOADS INCLUDE A 120A INSTANT ON-DEMAND ELECTRIC WATER HEATER.
6. EACH PV BRANCH CIRCUIT HAS AN OCPD BREAKER SIZE OF 20A, 2-POLE.
7. CONSUMPTION CTS MEASURE CONSUMPTION ON ALL LOADS AT SITE
F
SUNPOWER PROVIDED ENGAGE
CABLES
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
G
MICROINVERTER
HANWHA MODULES
ENPHASE CAN
BUS CABLE
ENPHASE CAN
BUS CABLE
40/15 2P QUAD
8 MODULES
7 MODULES
C
GND3
EATON DG223URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
UTILITY-LOCKABLE SAFETY SWITCH 100A, 240VAC
EATON DG222URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC
D
3
GND
UTILITY-LOCKABLE SAFETY
SWITCH 60A, 240VAC
EATON DG222URB OR EQUIVALENT
ESS AC DISCONNECT WITHIN LINE OF SIGHT
OF THE MAIN SERVICE PANEL
ESS BREAKER AS DISCONNECTING MEANS,
INSTALLED IN ACCORDANCE WITH 706.15
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
EER
S
T
ATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
PVE-1
UP
D
A
T
E
D
T
O
1
0
k
w
h
E
N
P
H
A
S
E
E
S
S
1
2
/
1
4
/
2
3
J
F
UP
D
A
T
E
D
A
C
D
&
S
Y
S
T
E
M
S
I
Z
E
T
O
6
.
0
8
K
W
01
/
0
3
/
2
4
J
F
UP
D
A
T
E
D
C
O
N
D
U
C
T
O
R
F
O
R
T
A
G
C
01
/
1
5
/
2
4
R
V
I
AD
D
E
D
E
S
S
A
C
D
I
S
C
O
N
N
E
C
T
03
/
2
0
/
2
4
R
V
I
05
/
2
0
/
2
4
R
V
I
UP
D
A
T
E
D
A
S
P
E
R
A
H
J
C
O
M
M
E
N
T
06/25/2024
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
EER
S
T
ATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
GARAGE FLOOR
CONCRETE CURB
PVS6
PVS6 MONITORING
HEAT DETECTOR (BY OTHERS)
IQ SYSTEM
CONTROLLER
ENPHASE IQ SYSTEM CONTROLLER
ENPHASE
IQ COMBINER
ENPHASE IQ COMBINER
ENPHASE
IQ BATTERY
ENPHASE
IQ BATTERY
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
EQ
U
I
P
M
E
N
T
E
L
E
V
A
T
I
O
N
&
P
L
A
C
A
R
D
PVE-2
DRIVEWAY
TYPICAL ESS DIRECTORY PLACARD
NOTE:
CUSTOMIZED PLACARD WILL BE PROVIDED
FOR EACH LOT(UNIT)
N
SERVICE BREAKER BATTERY SWITCH
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
CAUTION:
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
CAUTION:
PHOTOVOLTAIC
AC DISCONNECT (EXT)
PHOTOVOLTAICARRAY ON ROOF
(1 OF 2)
MAIN SERVICE PANEL (EXT)
YOU ARE HERE
BATTERY STORAGE (INT)
IQ SYSTEMCONTROLLER (INT)
IQ COMBINER (INT)
DRIVEWAY
N
PHOTOVOLTAIC
AC DISCONNECT (EXT)
PHOTOVOLTAICARRAY ON ROOF
MAIN SERVICE PANEL (EXT)
(1 OF 2)
BATTERY STORAGE (INT)
YOU ARE HERE
IQ SYSTEMCONTROLLER (INT)
IQ COMBINER (INT)
UP
D
A
T
E
D
T
O
1
0
k
w
h
E
N
P
H
A
S
E
E
S
S
1
2
/
1
4
/
2
3
J
F
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
T
O
6
.
0
8
K
W
01
/
1
5
/
2
4
R
V
I
RE
L
O
C
A
T
E
D
E
S
S
B
A
T
T
E
R
Y
03
/
2
0
/
2
4
R
V
I
PHOTOVOLTAIC
AC DISCONNECT (EXT)
ESS AC DISCONNECT (EXT)
PHOTOVOLTAIC
AC DISCONNECT (EXT)
ESS AC DISCONNECT (EXT)
IN
C
L
U
D
E
D
E
S
S
D
I
S
C
O
N
N
E
C
T
O
N
P
L
A
C
A
R
D
04
/
1
5
/
2
4
R
V
I
06/25/2024
FIGURE 1: ELECTRICAL SIGNAGES/STICKERS
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVERCURRENT DEVICE
x
x
x
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUTDOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR PV SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
RAPID SHUTDOWN SWITCH FOR
SOLAR PV SYSTEM
x
x
x
FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION
x
x
POWER SUPPLY SOURCES
WARNING
UTILITY GRID
PV ELECTRICAL SYSTEM
WARNING
ELECTRIC SHOCK HAZARD TERMINALS ON
THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION
AC SOLAR DISCONNECT
x
ENERGY STORAGE SYSTEM CONTAINS
ENERGIZED BATTERIES
SIGNAGE LOCATIONS:
x ENPHASE ENERGY STORAGE SYSTEM
x
x
x
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
AMPS
VOLTS
AMPS
VOLTS
PHOTOVOLTAIC POINT OF
INTERCONNECTION
WARNING: ELECTIC SHOCK HAZARD. DO NOT
TOUCH TERMINALS. TERMINALS ON BOTH THE
LINE AND LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION. FOR SERVICE
DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER
PV POWER SOURCE
MAXIMUM RATED AC OUTPUT CURRENT:
MAXIMUM OPERATING AC VOLTAGE:
24.00
240
24.00
240
6.08 kW 6.08 kW
UTILITY PV SYSTEM DISCONNECT
SAFETY SWITCH
FOR UTILITY OPERATION
AC DISCONNECT
SIGNAGE LOCATIONS:
x INDOOR / OUTDOOR AC DISCONNECT
!!
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
SIGNAGE LOCATIONS:
x MAIN SERVICE PANEL
x PANEL ENCLOSURE INTERIOR
x
x
!WARNING
TURN OFF UTILITY DG AC SAFETY
DISCONNECT PRIOR TO WORKING
IN METER SERVICE PANEL
SOLAR PV BREAKER
SIGNAGE LOCATIONS:
x MAIN SERVICE PANEL
x PANEL ENCLOSURE INTERIOR
BREAKER IS BACKFED
DO NOT RELOCATE
ENERGY STORAGE SYSTEM
DISCONNECT
x x
ENERGY STORAGE
SYSTEM DISCONNECT
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
120/240 VAC 60 HZ
86.4V
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
EER
S
T
ATEOF CA L I F O R NIA
CHI F UNG L
E
UN
G
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
PVE-3
UP
D
A
T
E
D
T
O
1
0
k
w
h
E
N
P
H
A
S
E
E
S
S
1
2
/
1
4
/
2
3
J
F
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
T
O
6
.
0
8
K
W
01
/
1
5
/
2
4
R
V
I
AD
D
E
D
E
S
S
D
I
S
C
O
N
N
E
C
T
S
I
G
N
A
G
E
03
/
2
0
/
2
4
R
V
I
AD
D
E
D
N
E
C
E
S
S
A
R
Y
E
S
S
S
I
G
N
A
G
E
04
/
1
5
/
2
4
R
V
I
06/25/2024
CURRENT TRANSFORMER SPECIFICATION SHEET
PVS6 DATASHEET 1 PVS6 DATASHEET 2 PVS6 INSTALLATION INSTRUCTIONS 2PVS6 INSTALLATION INSTRUCTIONS 1
Q-CABLE DATA SHEET 1/2 Q-CABLE DATA SHEET 2/2
ENPHASE DATA SHEET 1/2 ENPHASE DATA SHEET 2/2
CONDUCTOR AND OCP SIZING TABLE
CLASS A FIRE RATING LISTING PG 1/3 CLASS A FIRE RATING LISTING PG 2/3 CLASS A FIRE RATING LISTING PG 3/3 PV MODULE SPECIFICATION SHEET 1/2 PV MODULE SPECIFICATION SHEET 2/2
RAIL-MOUNTED JUNCTION BOX 1/2 RAIL-MOUNTED JUNCTION BOX 2/2UNIVERSAL INVISIMOUNT INSTALLATION GUIDE
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
EL
E
C
T
R
I
C
A
L
D
A
T
A
&
S
P
E
C
I
F
I
C
A
T
I
O
N
S
PVE-4
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
AC DISCONNECT DATA SHEET
ALUMINUM SERVICE ENTRANCE CABLE SHEET 1/2 ALUMINUM SERVICE ENTRANCE CABLE SHEET 2/2
INVISIMOUNT DATA SHEET
ENPHASE IQ SYSTEM CONTROLLER DATASHEET 1/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 2/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 3/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 4/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 5/6 ENPHASE IQ SYSTEM CONTROLLER DATASHEET 6/6
ENPHASE IQ COMBINER DATASHEET 1/4 ENPHASE IQ COMBINER DATASHEET 2/4 ENPHASE IQ COMBINER DATASHEET 3/4 ENPHASE IQ COMBINER DATASHEET 4/4
ENPHASE IQ BATTERY 5P DATASHEET 1/3 ENPHASE IQ BATTERY 5P DATASHEET 2/3 ENPHASE IQ BATTERY 5P DATASHEET 3/3
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
EL
E
C
T
R
I
C
A
L
D
A
T
A
&
S
P
E
C
I
F
I
C
A
T
I
O
N
S
PVE-5
SHEET
UP
D
A
T
E
D
T
O
1
0
k
w
h
E
N
P
H
A
S
E
E
S
S
1
2
/
1
4
/
2
3
J
F
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG
HEAT DETECTOR HEAT DETECTOR PG 1/4 HEAT DETECTOR PG 2/4 HEAT DETECTOR PG 3/4 HEAT DETECTOR PG 4/4
PO
I
N
T
H
A
P
P
Y
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
1
3
4
8
WI
L
L
I
A
M
S
H
O
M
E
S
21
0
8
0
C
E
N
T
R
E
P
O
I
N
T
E
P
A
R
K
W
A
Y
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
SA
N
T
A
C
L
A
R
I
T
A
,
C
A
9
1
3
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
88
0
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
®
E
LECT R I C A L
E22659
Exp. 03-31-25R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
R
E
V
I
S
I
O
N
S
EL
E
C
T
R
I
C
A
L
D
A
T
A
&
S
P
E
C
I
F
I
C
A
T
I
O
N
S
PVE-6
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID C003130
D-0129758
2024-05-20
VON INCIONG