BRES2019-0555 Title 24 AnalysisCERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 1 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
GENERAL INFORMATION
01
Project Name
Casa De Los Osos
02
Calculation Description
Title 24 Analysis
03
Project Location
80800 Via Portofino at Hideaway Country Club
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
B R ES2019-0555
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
Front Orientation (deg/Cardinal)
0
12
Project Scope
Newly Constructed
Number of Dwelling Units
1
CITY OF LA QU I NTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
n/fin /nnnn -tom
14
Total Cond. Floor Area (ft2)
4370
Number of Zones
4
16
Slab Area (ft2)
3350
Number of Stories
2
18
Addition Cond. Floor Area(ft2)
n/a
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
Glazing Percentage (%)
23.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
DATE"" """'"' BY
4,370SF S.F.D.
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.42
2.78
-0.36
-14.9%
Space Cooling
81.01
79.71
1.30
1.6%
IAQ Ventilation
0.85
0.85
0.00
0.0%
Water Heating
3.09
2.61
0.48
15.5%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
87.37
85.95
1.42
1.6%
Registration Number: 219-P0102637130-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 2 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
47.6
47.0
0.0
47.0
•
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
■
Design meets Tier 2 requirement of 30°/a or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
•
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ceiling has high level of insulation
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• -- None --
Registration Number: 219-P010263713C-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CalCERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 3 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Casa De Los Osos
4370
1
4
4
0
3
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Zone 2 - Master/Laundry
Conditioned
Zone 2 - Master/Laundryl
1500
10
DHW Sys 1
n/a
Zone 1 - Casita
Conditioned
Zone 1 - Casita2
470
10
DHW Sys 3
n/a
Zone 3 - Main Floor Guest
Conditioned
Zone 3 - Main Floor Guest3
1563
9
DHW Sys 5
n/a
Zone 4 - Kitchen/Living/W
Conditioned
Zone 4 - Kitchen/Living/W4
837
10
DHW Sys 5
n/a
CaICERTS,I�
HERS
Registration Number: 219-P0102637130-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2020-06-19 18:28:01
HERS Provider: CaICERTS inc.
Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 4 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
Exterior Wall Rear N - 33
Zone 2 - Master/Laundry
R-20 Wall plus 1 EPS
0
Front
387
156.75
90
Exterior Wall Right E - 3
Zone 2 - Master/Laundry
R-20 Wall plus 1 EPS
90
Left
450.45
32
90
Interior Surface Front to
Zone 2 - Master/Laundry
R-0 Wall
n/a
n/a
380.25
0
n/a
Interior Surface Left to
Zone 2 - Master/Laundry
R-0 Wall
n/a
n/a
111.15
0
n/a
Interior Surface Left to 2
Zone 2 - Master/Laundry
R-0 Wall
n/a
n/a
292.5
0
n/a
Roof
Zone 2 - Master/Laundry
R-48 Roof Attic plus 1 E
n/a
n/a
970
n/a
n/a
Exterior Wall Front S - 2
Zone 1 - Casita
R-20 Wall plus 1 EPS
180
Back
285
35
90
Exterior Wall Left W - 19
Zone 1 - Casita
R-20 Wall plus 1 EPS
270
Right
190
32.66
90
Exterior Wall Rear N - 28
Zone 1 - Casita
R-20 Wall plus 1 EPS
0
Front
285
88
90
Exterior Wall Right E - 1
Zone 1 - Casita
R-20 Wall plus 1 EPS
90
Left
190
0
90
Roof 2
Zone 1 - Casita
R-36 Roof Attic plus 1 E
n/a
n/a
470
n/a
n/a
Exterior Wall Front S - 1
Zone 3 - Main Floor Guest
R-20 Wall plus 1 EPS
180
Back
140.4
60
90
Exterior Wall Left W - 25
Zone 3 - Main Floor Guest
R-20 Wall plus 1 EPS
270
Right
292.5
30
90
Exterior Wall Front S - 5
Zone 3 - Main Floor Guest
R-20 Wall plus 1 EPS
180
Back
463.5
72
90
Exterior Wall Left W - 30
Zone 3 - Main Floor Guest
R-20 Wall plus 1 EPS
270
Right
270
105
90
Exterior Wall Rear N - 51
Zone 3 - Main Floor Guest
R-20 Wall plus 1 EPS
0
Front
463.5
0
90
Exterior Wall Right E - 3 2
Zone 3 - Main Floor Guest
R-20 Wall plus 1 EPS
90
Left
270
0
90
Interior Surface Front to 2
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
187.2
0
n/a
Interior Surface Rear to
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
111.15
0
n/a
Interior Surface Rear to 2
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
257.4
24
n/a
Interior Surface Right to
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
111.15
21.33
n/a
Interior Surface Right to 2
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
292.5
48
n/a
Interior Surface to 2nd f
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
819
0
n/a
Interior Surface Floor to
Zone 3 - Main Floor Guest
R-0 Wall
n/a
n/a
639
0
n/a
Roof 3
Zone 3 - Main Floor Guest
R-48 Roof Attic plus 1 E
n/a
n/a
580
n/a
n/a
Roof 4
Zone 3 - Main Floor Guest
R-36 Roof Attic plus 1 E
n/a
n/a
59
n/a
n/a
Exterior Wall Front S - 2 2
Zone 4 - Kitchen/Living/W
R-20 Wall plus 1 EPS
180
Back
304.2
168
90
Exterior Wall Left W - 43
Zone 4 - Kitchen/Living/W
R-20 Wall plus 1 EPS
270
Right
508.4
180.6
90
Exterior Wall Rear N - 52
Zone 4 - Kitchen/Living/W
R-20 Wall plus 1 EPS
0
Front
614.25
216
90
Exterior Wall Right E - 3 3
Zone 4 - Kitchen/Living/W
R-20 Wall plus 1 EPS
90
Left
40.95
0
90
Registration Number: 219-P0102637130-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 5 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
Interior Surface Right to 3
Zone 4 - Kitchen/Living/W
R-0 Wall
n/a
n/a
269.1
0
n/a
Roof 5
Zone 4 - Kitchen/Living/W
R-48 Roof Attic plus 1 E
n/a
n/a
1091
n/a
n/a
Exterior Wall Front S - 4
_Garage_
R-20 Wall plus 1 EPS
180
Back
495
189
90
Exterior Wall Left W - 25 2
_Garage_
R-20 Wall plus 1 EPS
270
Right
255
0
90
Exterior Wall Rear N - 4.
_Garage_
R-20 Wall plus 1 EPS
0
Front
45
0
90
Exterior Wall Right E - 5
Garage
R-20 Wall plus 1 EPS
90
Left
505
192
90
Roof 6
Garage
R-36 Roof Attic plus 1 E
n/a
n/a
1327
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Zone 2 -
Master/Laundry
Attic RoofZone 2 -
Master/Laundry
Ventilated
3
0.1
0.85
Yes
No
Attic Zone 1 - Casita
Attic RoofZone 1 - Casita
Ventilated
3
0.1
0.85
Yes
No
Attic Zone 3 - Main Floor
Guest
Attic RoofZone 3 - Main Floor
Guest
Ventilated
3
0.1
0.85
Yes
No
Attic Zone 4 -
Kitchen/Living/W
Attic RoofZone 4 -
Kitchen/Living/W
Ventilated
3 0.1
I
0.85
Yes
No
Attic _Garage_
Attic Garage Roof Cons
Ventilated
3 413/ 0.71 &
0.85
Yes
No
OVI DE
Registration Number: 219-P010263713C-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2020-06-19 18:28:01
HERS Provider: CalCERTS inc.
Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 6 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Sliding Glass Door 07 - 1
Window
Exterior Wall Rear N - 33 (Front-0)
----
----
1
108.0
0.35
0.21
Insect Screen (default)
Window 06 - 2666
Window
Exterior Wall Rear N - 33 (Front-0)
----
1
16.3
0.40
0.17
Insect Screen (default)
Window 07 - 2666
Window
Exterior Wall Rear N - 33 (Front-0)
----
1
16.3
0.40
0.17
Insect Screen (default)
Window 08 - 2666
Window
Exterior Wall Rear N - 33 (Front-0)
----
1
16.3
0.40
0.17
Insect Screen (default)
Glass In -Swing Door 06 -
Window
Exterior Wall Right E - 3 (Left-90)
----
----
1
32.0
0.35
0.21
Insect Screen (default)
Window 12 - 7050
Window
Exterior Wall Front S - 2 (Back-180)
----
----
1
35.0
0.40
0.17
Insect Screen (default)
Sliding Glass Door 13 - 1
Window
Exterior Wall Rear N - 28 (Front-0)
----
----
1
88.0
0.35
0.21
Insect Screen (default)
Window 01 - 2660
Window
Exterior Wall Left W - 25 (Right-270)
----
1
15.0
0.40
0.17
Insect Screen (default)
Window 02 - 2660
Window
Exterior Wall Left W - 25 (Right-270)
----
1
15.0
0.40
0.17
Insect Screen (default)
Window 13 - 2020
Window
Exterior Wall Front S - 5 (Back-180)
1
4.0
0.24
0.23
Insect Screen (default)
Window 14 - 2020
Window
Exterior Wall Front S - 5 (Back-180)
----
----
1
4.0
0.24
0.23
Insect Screen (default)
Window 15 - 2020
Window
Exterior Wall Front S - 5 (Back-180)
----
----
1
4.0
0.24
0.23
Insect Screen (default)
Window 16 - 2660
Window
Exterior Wall Front S - 5 (Back-180)
----
----
1
15.0
0.40
0.17
Insect Screen (default)
Window 17 - 2660
Window
Exterior Wall Front S - 5 (Back-180)
----
----
1
15.0
0.40
0.17
Insect Screen (default)
Window 18 - 2640
Window
Exterior Wall Front S - 5 (Back-180)
----
1
10.0
0.40
0.17
Insect Screen (default)
Window 19 - 2640
Window
Exterior Wall Front S - 5 (Back-180)
----
----
1
10.0
0.24
0.23
Insect Screen (default)
Window 20 - 2640
Window
Exterior Wall Front S - 5 (Back-180)
----
----
1
10.0
0.40
0.17
Insect Screen (default)
Sliding Glass Door 36 - 1
Window
Exterior Wall Left W - 30 (Right-270)
----
----
1
105.0
0.35
0.21
Insect Screen (default)
Sliding Glass Door 12 - 1
Window
Exterior Wall Front S - 2 2 (Back-180)
----
----
1
153.0
0.35
0.21
Insect Screen (default)
Window 11 - 2660
Window
Exterior Wall Front S - 2 2 (Back-180)
----
----
1
15.0
0.24
0.23
Insect Screen (default)
Window 10 - 4040
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
16.0
0.40
0.17
Insect Screen (default)
Glass Door 09 - 3080
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
24.0
0.35
0.21
Insect Screen (default)
Window 28 - 5026
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
14.2
0.24
0.23
Insect Screen (default)
Window 29 - 5026
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
14.2
0.24
0.23
Insect Screen (default)
Window 30 - 5026
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
14.2
0.24
0.23
Insect Screen (default)
Window 31 - 4620
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
9.0
0.24
0.23
Insect Screen (default)
Window 32 - 4620
Window
Exterior Wall Left W - 43 (Right-270)
----
----
1
9.0
0.24
0.23
Insect Screen (default)
Window 09 - 6060
Window
Exterior Wall Rear N - 52 (Front-0)
----
----
1
36.0
0.35
0.21
Insect Screen (default)
Sliding Glass Door 08 - 1
Window
Exterior Wall Rear N - 52 (Front-0)
----
----
1
180.0
0.35
0.21
Insect Screen (default)
Registration Number: 219-P0102637130-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 7 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
Window 03 - 2660
Window
Exterior Wall Front S - 4 (Back-180)
----
----
1
15.0
0.24
0.23
Insect Screen (default)
Window 04 - 2660
Window
Exterior Wall Front S - 4 (Back-180)
----
----
1
15.0
0.24
0.23
Insect Screen (default)
Window 05 - 2660
Window
Exterior Wall Front S - 4 (Back-180)
----
----
1
15.0
0.24
0.23
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door 37 - 4870
Exterior Wall Left W - 19
32.7
0.50
Door 01 - 60100
Exterior Wall Front S - 1
60.0
0.50
Door 11 - 5080
Exterior Wall Left W - 43
40.0
0.50
Door 10 - 5080
Exterior Wall Left W - 43
40.0
0.50
Garage Door 04 - 18080
Exterior Wall Front S - 4
144.0
1.00
Door 05 - 3080
Exterior Wall Right E - 5
24.0
0.50
Garage Door 03 - 18080
Exterior Wall Right E - 5
144.0
1.00
Door 02 - 3080
Exterior Wall Right E - 5
24.0
0.50
A CaICERTSHERS , Ir
Registration Number: 219-P0102637130-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2020-06-19 18:28:01
HERS Provider: CaICERTS inc.
Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 8 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Winter Design
U-factor
Assembly Layers
R-20 Wall plus 1 EPS
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19 in 5-1/2 in.
cavity (R-18)
0.051
• Inside Finish: Gypsum Board
• Sheathing / Insulation: R1 Sheathing
• Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
• Sheathing/Insulation: R4.2 Sheathing
• Exterior Finish: 3 Coat Stucco
R-36 Roof Attic plus 1 E
Ceilings (below
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 30
0.032
• Inside Finish: Gypsum Board
• Cavity/Frame: R-9.1 /2x4
• Over Ceiling Joists: R-20.9 insul.
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 6
0.087
• Cavity / Frame: R-6 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R4.2 Sheathing
• Roofing: Light Roof (Asphalt Shingle)
Attic RoofZone 2 -
Master/Laundry
Attic Roofs
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 4
0.104
• Cavity / Frame: R-4 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R4.2 Sheathing
• Roofing: Light Roof (Asphalt Shingle)
R-0 Wall
Interior Walls
Wood Framed Wall
2x4 @ 24 in. O.C.
none
0.282
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
• Other Side Finish: Gypsum Board
R-48 Roof Attic plus 1 E
Ceilings (below
attic)
Wood Framed Ceiling
2x12 @ 24 in. O.C.
R 44
0.023
• Inside Finish: Gypsum Board
• Cavity / Frame: R-29.2/2x12
• Over Ceiling Joists: R-14.8 insul.
Attic RoofZone 1 - Casita
Attic Roofs
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 6
0.087
• Cavity / Frame: R-6 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R4.2 Sheathing
• Roofing: Light Roof (Asphalt Shingle)
Attic RoofZone 3 - Main Floor
Guest
Attic Roofs
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 4
0.104
• Cavity / Frame: R-4 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R4.2 Sheathing
• Roofing: Light Roof (Asphalt Shingle)
Attic RoofZone 4 -
Kitchen/Living/W
Attic Roofs
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 4
0.104
• Cavity / Frame: R-4 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R4.2 Sheathing
• Roofing: Light Roof (Asphalt Shingle)
Registration Number: 219-P0102637130-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 9 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Zone 2 - Master/Laundry
970
0.1
None
0.8
No
Slab -on -Grade 2
Zone 1 - Casita
470
0.1
None
0.8
No
Slab -on -Grade 3
Zone 3 - Main Floor Guest
819
0.1
None
0.8
No
Slab -on -Grade 4
Zone 4 - Kitchen/Living/W
1091
0.1
None
0.8
No
Slab -on -Grade 5
Garage
1327
0.1
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
DHW Sys 3
DHW
Standard
DHW Heater 3 (1)
1
.0%
DHW Sys 5
DHW
Standard
DHW Heater 5 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
Small
Instantaneous
1
0
0.97 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 3
Gas
Small
Instantaneous
1
0
0.97 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
Registration Number: 219-P010263713C-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 10 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 5
Gas
Small
Instantaneous
1
0
0.97 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Zone 2 - Master/Laundry1
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
Zone 1 - Casita2
Heat Pump Heating and
Cooling System
Heat Pump System 2
Heat Pump System 2
HVAC Fan 2
Air Distribution System 2
Zone 3 - Main Floor Guest3
Heat Pump Heating and
Cooling System
Heat Pump System 3
Heat Pump System 3
HVAC Fan 3
Air Distribution System 3
Zone 4 - Kitchen/Living/W4
Heat Pump Heating and
Cooling System
Heat Pump System 4
Heat Pump System 4
HVAC Fan 4
Air Distribution System 4
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
1
9.2
60000
55750
16
11.9
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
Heat Pump System 2
SplitHeatPump
1
9.2
25000
23750
16
11.9
Not Zonal
Single Speed
Heat Pump System
2-hers-cool
Heat Pump System 3
SplitHeatPump
1
9.2
78000
69500
16
11.9
Not Zonal
Single Speed
Heat Pump System
3-hers-cool
Heat Pump System 4
SplitHeatPump
1
9.2
96800
85500
16
11.9
Not Zonal
Single Speed
Heat Pump System
4-hers-cool
Registration Number: 219-P0102637130-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 11 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Required
Required
Required
Heat Pump System 2-hers-cool
Required
350
Required
Required
Required
Heat Pump System 3-hers-cool
Required
350
Required
Required
Required
Heat Pump System 4-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
2-hers-dist
Air Distribution System 3
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
3-hers-dist
Air Distribution System 4
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
4-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 3-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 4-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Registration Number: 219-P0102637130-000-000-0000000-0000
Registration Date/Time: 2020-06-19 18:28:01
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 12 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Waft Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
81
0.25
Default
0
Required
Registration Number: 219-P0102637130-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2020-06-19 18:28:01
HERS Provider: CaICERTS inc.
Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 13 of 13
Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x
Project Name: Casa De Los Osos
Calculation Description: Title 24 Analysis
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Michele J Kler
Documentation Author Signaturr-
cyki deeed c9t
Company:
Advancing Home Performance, Inc.
Signature Date:
2020-06-19 16:14:48
Address:
74998 Country Club Drive.
CEA/HERS Certification Identification (If applicable):
CA809080
City/State/Zip:
Palm Desert, CA 92260
Phone:
760-851-8648
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Christine Thomas
Responsible Designer Signature.
"� v71,67,166.
Company:
Thomas Johnson
Date Signed:
2020-06-19 18:28:01
Address:
101- 73399 el Paseo drive
License:
.
City/State/Zip:
Palm desert, CA 92260
Phone:
760-972-7504
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Number: 219-P0102637130-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2020-06-19 18:28:01
HERS Provider: CaICERTS inc.
Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47