Loading...
BRES2019-0555 Title 24 AnalysisCERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 1 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis GENERAL INFORMATION 01 Project Name Casa De Los Osos 02 Calculation Description Title 24 Analysis 03 Project Location 80800 Via Portofino at Hideaway Country Club 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 B R ES2019-0555 09 Software Version EnergyPro 7.2 10 Building Type Single Family Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed Number of Dwelling Units 1 CITY OF LA QU I NTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE n/fin /nnnn -tom 14 Total Cond. Floor Area (ft2) 4370 Number of Zones 4 16 Slab Area (ft2) 3350 Number of Stories 2 18 Addition Cond. Floor Area(ft2) n/a Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a Glazing Percentage (%) 23.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 DATE"" """'"' BY 4,370SF S.F.D. This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.42 2.78 -0.36 -14.9% Space Cooling 81.01 79.71 1.30 1.6% IAQ Ventilation 0.85 0.85 0.00 0.0% Water Heating 3.09 2.61 0.48 15.5% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 87.37 85.95 1.42 1.6% Registration Number: 219-P0102637130-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 2 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 47.6 47.0 0.0 47.0 • Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ■ Design meets Tier 2 requirement of 30°/a or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) • renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ceiling has high level of insulation HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- Registration Number: 219-P010263713C-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CalCERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 3 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Casa De Los Osos 4370 1 4 4 0 3 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 2 - Master/Laundry Conditioned Zone 2 - Master/Laundryl 1500 10 DHW Sys 1 n/a Zone 1 - Casita Conditioned Zone 1 - Casita2 470 10 DHW Sys 3 n/a Zone 3 - Main Floor Guest Conditioned Zone 3 - Main Floor Guest3 1563 9 DHW Sys 5 n/a Zone 4 - Kitchen/Living/W Conditioned Zone 4 - Kitchen/Living/W4 837 10 DHW Sys 5 n/a CaICERTS,I� HERS Registration Number: 219-P0102637130-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2020-06-19 18:28:01 HERS Provider: CaICERTS inc. Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 4 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Exterior Wall Rear N - 33 Zone 2 - Master/Laundry R-20 Wall plus 1 EPS 0 Front 387 156.75 90 Exterior Wall Right E - 3 Zone 2 - Master/Laundry R-20 Wall plus 1 EPS 90 Left 450.45 32 90 Interior Surface Front to Zone 2 - Master/Laundry R-0 Wall n/a n/a 380.25 0 n/a Interior Surface Left to Zone 2 - Master/Laundry R-0 Wall n/a n/a 111.15 0 n/a Interior Surface Left to 2 Zone 2 - Master/Laundry R-0 Wall n/a n/a 292.5 0 n/a Roof Zone 2 - Master/Laundry R-48 Roof Attic plus 1 E n/a n/a 970 n/a n/a Exterior Wall Front S - 2 Zone 1 - Casita R-20 Wall plus 1 EPS 180 Back 285 35 90 Exterior Wall Left W - 19 Zone 1 - Casita R-20 Wall plus 1 EPS 270 Right 190 32.66 90 Exterior Wall Rear N - 28 Zone 1 - Casita R-20 Wall plus 1 EPS 0 Front 285 88 90 Exterior Wall Right E - 1 Zone 1 - Casita R-20 Wall plus 1 EPS 90 Left 190 0 90 Roof 2 Zone 1 - Casita R-36 Roof Attic plus 1 E n/a n/a 470 n/a n/a Exterior Wall Front S - 1 Zone 3 - Main Floor Guest R-20 Wall plus 1 EPS 180 Back 140.4 60 90 Exterior Wall Left W - 25 Zone 3 - Main Floor Guest R-20 Wall plus 1 EPS 270 Right 292.5 30 90 Exterior Wall Front S - 5 Zone 3 - Main Floor Guest R-20 Wall plus 1 EPS 180 Back 463.5 72 90 Exterior Wall Left W - 30 Zone 3 - Main Floor Guest R-20 Wall plus 1 EPS 270 Right 270 105 90 Exterior Wall Rear N - 51 Zone 3 - Main Floor Guest R-20 Wall plus 1 EPS 0 Front 463.5 0 90 Exterior Wall Right E - 3 2 Zone 3 - Main Floor Guest R-20 Wall plus 1 EPS 90 Left 270 0 90 Interior Surface Front to 2 Zone 3 - Main Floor Guest R-0 Wall n/a n/a 187.2 0 n/a Interior Surface Rear to Zone 3 - Main Floor Guest R-0 Wall n/a n/a 111.15 0 n/a Interior Surface Rear to 2 Zone 3 - Main Floor Guest R-0 Wall n/a n/a 257.4 24 n/a Interior Surface Right to Zone 3 - Main Floor Guest R-0 Wall n/a n/a 111.15 21.33 n/a Interior Surface Right to 2 Zone 3 - Main Floor Guest R-0 Wall n/a n/a 292.5 48 n/a Interior Surface to 2nd f Zone 3 - Main Floor Guest R-0 Wall n/a n/a 819 0 n/a Interior Surface Floor to Zone 3 - Main Floor Guest R-0 Wall n/a n/a 639 0 n/a Roof 3 Zone 3 - Main Floor Guest R-48 Roof Attic plus 1 E n/a n/a 580 n/a n/a Roof 4 Zone 3 - Main Floor Guest R-36 Roof Attic plus 1 E n/a n/a 59 n/a n/a Exterior Wall Front S - 2 2 Zone 4 - Kitchen/Living/W R-20 Wall plus 1 EPS 180 Back 304.2 168 90 Exterior Wall Left W - 43 Zone 4 - Kitchen/Living/W R-20 Wall plus 1 EPS 270 Right 508.4 180.6 90 Exterior Wall Rear N - 52 Zone 4 - Kitchen/Living/W R-20 Wall plus 1 EPS 0 Front 614.25 216 90 Exterior Wall Right E - 3 3 Zone 4 - Kitchen/Living/W R-20 Wall plus 1 EPS 90 Left 40.95 0 90 Registration Number: 219-P0102637130-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 5 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis Interior Surface Right to 3 Zone 4 - Kitchen/Living/W R-0 Wall n/a n/a 269.1 0 n/a Roof 5 Zone 4 - Kitchen/Living/W R-48 Roof Attic plus 1 E n/a n/a 1091 n/a n/a Exterior Wall Front S - 4 _Garage_ R-20 Wall plus 1 EPS 180 Back 495 189 90 Exterior Wall Left W - 25 2 _Garage_ R-20 Wall plus 1 EPS 270 Right 255 0 90 Exterior Wall Rear N - 4. _Garage_ R-20 Wall plus 1 EPS 0 Front 45 0 90 Exterior Wall Right E - 5 Garage R-20 Wall plus 1 EPS 90 Left 505 192 90 Roof 6 Garage R-36 Roof Attic plus 1 E n/a n/a 1327 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 2 - Master/Laundry Attic RoofZone 2 - Master/Laundry Ventilated 3 0.1 0.85 Yes No Attic Zone 1 - Casita Attic RoofZone 1 - Casita Ventilated 3 0.1 0.85 Yes No Attic Zone 3 - Main Floor Guest Attic RoofZone 3 - Main Floor Guest Ventilated 3 0.1 0.85 Yes No Attic Zone 4 - Kitchen/Living/W Attic RoofZone 4 - Kitchen/Living/W Ventilated 3 0.1 I 0.85 Yes No Attic _Garage_ Attic Garage Roof Cons Ventilated 3 413/ 0.71 & 0.85 Yes No OVI DE Registration Number: 219-P010263713C-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2020-06-19 18:28:01 HERS Provider: CalCERTS inc. Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 6 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Sliding Glass Door 07 - 1 Window Exterior Wall Rear N - 33 (Front-0) ---- ---- 1 108.0 0.35 0.21 Insect Screen (default) Window 06 - 2666 Window Exterior Wall Rear N - 33 (Front-0) ---- 1 16.3 0.40 0.17 Insect Screen (default) Window 07 - 2666 Window Exterior Wall Rear N - 33 (Front-0) ---- 1 16.3 0.40 0.17 Insect Screen (default) Window 08 - 2666 Window Exterior Wall Rear N - 33 (Front-0) ---- 1 16.3 0.40 0.17 Insect Screen (default) Glass In -Swing Door 06 - Window Exterior Wall Right E - 3 (Left-90) ---- ---- 1 32.0 0.35 0.21 Insect Screen (default) Window 12 - 7050 Window Exterior Wall Front S - 2 (Back-180) ---- ---- 1 35.0 0.40 0.17 Insect Screen (default) Sliding Glass Door 13 - 1 Window Exterior Wall Rear N - 28 (Front-0) ---- ---- 1 88.0 0.35 0.21 Insect Screen (default) Window 01 - 2660 Window Exterior Wall Left W - 25 (Right-270) ---- 1 15.0 0.40 0.17 Insect Screen (default) Window 02 - 2660 Window Exterior Wall Left W - 25 (Right-270) ---- 1 15.0 0.40 0.17 Insect Screen (default) Window 13 - 2020 Window Exterior Wall Front S - 5 (Back-180) 1 4.0 0.24 0.23 Insect Screen (default) Window 14 - 2020 Window Exterior Wall Front S - 5 (Back-180) ---- ---- 1 4.0 0.24 0.23 Insect Screen (default) Window 15 - 2020 Window Exterior Wall Front S - 5 (Back-180) ---- ---- 1 4.0 0.24 0.23 Insect Screen (default) Window 16 - 2660 Window Exterior Wall Front S - 5 (Back-180) ---- ---- 1 15.0 0.40 0.17 Insect Screen (default) Window 17 - 2660 Window Exterior Wall Front S - 5 (Back-180) ---- ---- 1 15.0 0.40 0.17 Insect Screen (default) Window 18 - 2640 Window Exterior Wall Front S - 5 (Back-180) ---- 1 10.0 0.40 0.17 Insect Screen (default) Window 19 - 2640 Window Exterior Wall Front S - 5 (Back-180) ---- ---- 1 10.0 0.24 0.23 Insect Screen (default) Window 20 - 2640 Window Exterior Wall Front S - 5 (Back-180) ---- ---- 1 10.0 0.40 0.17 Insect Screen (default) Sliding Glass Door 36 - 1 Window Exterior Wall Left W - 30 (Right-270) ---- ---- 1 105.0 0.35 0.21 Insect Screen (default) Sliding Glass Door 12 - 1 Window Exterior Wall Front S - 2 2 (Back-180) ---- ---- 1 153.0 0.35 0.21 Insect Screen (default) Window 11 - 2660 Window Exterior Wall Front S - 2 2 (Back-180) ---- ---- 1 15.0 0.24 0.23 Insect Screen (default) Window 10 - 4040 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 16.0 0.40 0.17 Insect Screen (default) Glass Door 09 - 3080 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 24.0 0.35 0.21 Insect Screen (default) Window 28 - 5026 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 14.2 0.24 0.23 Insect Screen (default) Window 29 - 5026 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 14.2 0.24 0.23 Insect Screen (default) Window 30 - 5026 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 14.2 0.24 0.23 Insect Screen (default) Window 31 - 4620 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 9.0 0.24 0.23 Insect Screen (default) Window 32 - 4620 Window Exterior Wall Left W - 43 (Right-270) ---- ---- 1 9.0 0.24 0.23 Insect Screen (default) Window 09 - 6060 Window Exterior Wall Rear N - 52 (Front-0) ---- ---- 1 36.0 0.35 0.21 Insect Screen (default) Sliding Glass Door 08 - 1 Window Exterior Wall Rear N - 52 (Front-0) ---- ---- 1 180.0 0.35 0.21 Insect Screen (default) Registration Number: 219-P0102637130-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 7 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis Window 03 - 2660 Window Exterior Wall Front S - 4 (Back-180) ---- ---- 1 15.0 0.24 0.23 Insect Screen (default) Window 04 - 2660 Window Exterior Wall Front S - 4 (Back-180) ---- ---- 1 15.0 0.24 0.23 Insect Screen (default) Window 05 - 2660 Window Exterior Wall Front S - 4 (Back-180) ---- ---- 1 15.0 0.24 0.23 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door 37 - 4870 Exterior Wall Left W - 19 32.7 0.50 Door 01 - 60100 Exterior Wall Front S - 1 60.0 0.50 Door 11 - 5080 Exterior Wall Left W - 43 40.0 0.50 Door 10 - 5080 Exterior Wall Left W - 43 40.0 0.50 Garage Door 04 - 18080 Exterior Wall Front S - 4 144.0 1.00 Door 05 - 3080 Exterior Wall Right E - 5 24.0 0.50 Garage Door 03 - 18080 Exterior Wall Right E - 5 144.0 1.00 Door 02 - 3080 Exterior Wall Right E - 5 24.0 0.50 A CaICERTSHERS , Ir Registration Number: 219-P0102637130-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2020-06-19 18:28:01 HERS Provider: CaICERTS inc. Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 8 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers R-20 Wall plus 1 EPS Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 in 5-1/2 in. cavity (R-18) 0.051 • Inside Finish: Gypsum Board • Sheathing / Insulation: R1 Sheathing • Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6 • Sheathing/Insulation: R4.2 Sheathing • Exterior Finish: 3 Coat Stucco R-36 Roof Attic plus 1 E Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 30 0.032 • Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 • Over Ceiling Joists: R-20.9 insul. Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O.C. R 6 0.087 • Cavity / Frame: R-6 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Above Deck Insulation: R4.2 Sheathing • Roofing: Light Roof (Asphalt Shingle) Attic RoofZone 2 - Master/Laundry Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O.C. R 4 0.104 • Cavity / Frame: R-4 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Above Deck Insulation: R4.2 Sheathing • Roofing: Light Roof (Asphalt Shingle) R-0 Wall Interior Walls Wood Framed Wall 2x4 @ 24 in. O.C. none 0.282 • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 • Other Side Finish: Gypsum Board R-48 Roof Attic plus 1 E Ceilings (below attic) Wood Framed Ceiling 2x12 @ 24 in. O.C. R 44 0.023 • Inside Finish: Gypsum Board • Cavity / Frame: R-29.2/2x12 • Over Ceiling Joists: R-14.8 insul. Attic RoofZone 1 - Casita Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O.C. R 6 0.087 • Cavity / Frame: R-6 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Above Deck Insulation: R4.2 Sheathing • Roofing: Light Roof (Asphalt Shingle) Attic RoofZone 3 - Main Floor Guest Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O.C. R 4 0.104 • Cavity / Frame: R-4 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Above Deck Insulation: R4.2 Sheathing • Roofing: Light Roof (Asphalt Shingle) Attic RoofZone 4 - Kitchen/Living/W Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O.C. R 4 0.104 • Cavity / Frame: R-4 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Above Deck Insulation: R4.2 Sheathing • Roofing: Light Roof (Asphalt Shingle) Registration Number: 219-P0102637130-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 9 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Zone 2 - Master/Laundry 970 0.1 None 0.8 No Slab -on -Grade 2 Zone 1 - Casita 470 0.1 None 0.8 No Slab -on -Grade 3 Zone 3 - Main Floor Guest 819 0.1 None 0.8 No Slab -on -Grade 4 Zone 4 - Kitchen/Living/W 1091 0.1 None 0.8 No Slab -on -Grade 5 Garage 1327 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% DHW Sys 3 DHW Standard DHW Heater 3 (1) 1 .0% DHW Sys 5 DHW Standard DHW Heater 5 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Instantaneous 1 0 0.97 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 3 Gas Small Instantaneous 1 0 0.97 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a Registration Number: 219-P010263713C-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 10 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 5 Gas Small Instantaneous 1 0 0.97 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Zone 2 - Master/Laundry1 Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Zone 1 - Casita2 Heat Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 Zone 3 - Main Floor Guest3 Heat Pump Heating and Cooling System Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 Zone 4 - Kitchen/Living/W4 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 SplitHeatPump 1 9.2 60000 55750 16 11.9 Not Zonal Single Speed Heat Pump System 1-hers-cool Heat Pump System 2 SplitHeatPump 1 9.2 25000 23750 16 11.9 Not Zonal Single Speed Heat Pump System 2-hers-cool Heat Pump System 3 SplitHeatPump 1 9.2 78000 69500 16 11.9 Not Zonal Single Speed Heat Pump System 3-hers-cool Heat Pump System 4 SplitHeatPump 1 9.2 96800 85500 16 11.9 Not Zonal Single Speed Heat Pump System 4-hers-cool Registration Number: 219-P0102637130-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 11 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Required 350 Required Required Required Heat Pump System 2-hers-cool Required 350 Required Required Required Heat Pump System 3-hers-cool Required 350 Required Required Required Heat Pump System 4-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2-hers-dist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 4-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Registration Number: 219-P0102637130-000-000-0000000-0000 Registration Date/Time: 2020-06-19 18:28:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 12 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Waft Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 0.58 HVAC Fan 4-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 81 0.25 Default 0 Required Registration Number: 219-P0102637130-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2020-06-19 18:28:01 HERS Provider: CaICERTS inc. Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Calculation Date/Time: 16:04, Fri, Jun 19, 2020 Page 13 of 13 Input File Name: Christine Thomas - Casa De Los Osos - Revision 6-16-20.ribdl6x Project Name: Casa De Los Osos Calculation Description: Title 24 Analysis DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Michele J Kler Documentation Author Signaturr- cyki deeed c9t Company: Advancing Home Performance, Inc. Signature Date: 2020-06-19 16:14:48 Address: 74998 Country Club Drive. CEA/HERS Certification Identification (If applicable): CA809080 City/State/Zip: Palm Desert, CA 92260 Phone: 760-851-8648 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Christine Thomas Responsible Designer Signature. "� v71,67,166. Company: Thomas Johnson Date Signed: 2020-06-19 18:28:01 Address: 101- 73399 el Paseo drive License: . City/State/Zip: Palm desert, CA 92260 Phone: 760-972-7504 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 219-P0102637130-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2020-06-19 18:28:01 HERS Provider: CaICERTS inc. Report Version - CF1 R-01162019-1149 Report Generated at: 2020-06-19 16:05:47