Loading...
Washington Street Apartments TR 12323 BCPR2017-0001 - RFI - Revised Party Wall DetailWOOD STUDS @ 16" O.C. PER STRUCTURAL @ WALL 2.1 - USE 2x4 STUDS @ WALL 2.2 - USE 2x6 STUDS (1) LAYER 5/8" GYP. BD. EA SIDE. AT 1 HOUR CONDITIONS, USE TYPE "X" EA. SIDE. PROVIDE FIBERGLASS BACKED GYP. BD. WHERE 'WET' AREAS OCCUR INSULATION (WHERE OCCURS AT BATHROOM AND UTILITY ROOM WALLS) 2.1 FIRE RATING: 1 HOUR WHERE REQUIRED SOUND RATING: NOT REQUIRED TEST ASSEMBLY: GA FILE NO. WP 3605 INTERIOR FINISH PER SPECIFICATIONS OR PLANS MAY CONSIST OF: PAINT, CERAMIC TILE, FIBERGLASS REINFORCED PLASTIC (FRP), ETC. SEE GENERAL NOTES ON PLAN SHEETS FOR WALLS REQUIRING 1 HOUR FIRE RATING ATTACH GYP. BD. PARALLEL OR PERP. TO STUDS W/ 6d COATED NAILS, 1 7/8" LONG, 0.0915" SHANK, 1/4" HEADS AT 7" O.C. STAGGER JOINTS 16" ON OPPOSITE SIDES. INTERIOR WALL 2.2 NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. WOOD STUDS @ 16" O.C. PER STRUCTURAL @ WALL 2.1a - USE 2x4 STUDS @ WALL 2.2a - USE 2x6 STUDS (1) LAYER 5/8" GYP. BD., PROVIDE FIBERGLASS BACKED GYP. BD. WHERE 'WET' AREAS OCCUR INSULATION AS REQUIRED PER ASSEMBLY 2.1a FIRE RATING: NOT REQUIRED SOUND RATING: NOT REQUIRED INTERIOR FINISH PER SPECIFICATIONS OR PLANS MAY CONSIST OF: PAINT, CERAMIC TILE, FIBERGLASS REINFORCED PLASTIC (FRP), ETC. INTERIOR WALL 2.2a NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. 2X6 WOOD STUDS @ 16" O.C. PER STRUCTURAL (1) LAYER 5/8" GYP. BD. EA SIDE, PROVIDE FIBERGLASS BACKED GYP. BD. WHERE 'WET' AREAS OCCUR INSULATION WHERE REQUIRED PER ASSEMBLY INTERIOR FINISH PER SPECIFICATIONS OR PLANS MAY CONSIST OF: PAINT, CERAMIC TILE, FIBERGLASS REINFORCED PLASTIC (FRP), ETC. FIRE RATING: 1 HOUR WHERE REQUIRED SOUND RATING: 50 -54 STC MIN. 50 STC REQ'D TEST ASSEMBLY: GA FILE NO. WP 3243 RESILIENT CHANNELS AT 24" O.C. ATTACH GYP. BD. PERP. TO RESILIENT CHANNELS W/ 1" TYPE S DRYWALL SCREWS, 8" O.C. W/ VERTICAL JOINTS LOCATED MIDWAY BETWEEN STUDS. OPPOSITE SIDE ATTACH GYP. BD. PARALLEL OR PERP. TO STUDS W/ 6d COATED NAILS, 1 7/8" LONG, 0.0915" SHANK, 15/64" HEADS AT 7" O.C. STAGGER JOINTS 24" ON OPPOSITE SIDES. INTERIOR WALL 2.3 NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. EXTERIOR PLYWOOD SHEATHING OR SHEAR PANEL WHERE OCCURS PER STRUCTURAL INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. 2X6 WOOD STUDS @ 16" O.C. PER STRUCTURAL (1) LAYER 5/8" GYP. BD. EA SIDE, PROVIDE FIBERGLASS BACKED GYP. BD. WHERE 'WET' AREAS OCCUR INSULATION AS REQUIRED PER ASSEMBLY INTERIOR FINISH PER SPECIFICATIONS OR PLANS MAY CONSIST OF: PAINT, CERAMIC TILE, FIBERGLASS REINFORCED PLASTIC (FRP), ETC. FIRE RATING: 1 HOUR WHERE REQUIRED SOUND RATING: 50 -54 STC MIN. 50 STC REQ'D TEST ASSEMBLY: GA FILE NO. WP 3243 RESILIENT CHANNELS AT 24" O.C. ATTACH GYP. BD. PERP. TO RESILIENT CHANNELS W/ 1" TYPE S DRYWALL SCREWS, 8" O.C. W/ VERTICAL JOINTS LOCATED MIDWAY BETWEEN STUDS. OPPOSITE SIDE ATTACH GYP. BD. PARALLEL OR PERP. TO STUDS W/ 6d COATED NAILS, 1 7/8" LONG, 0.0915" SHANK, 15/64" HEADS AT 7" O.C. STAGGER JOINTS 24" ON OPPOSITE SIDES. INTERIOR WALL 2.3a NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. 2X6 WOOD STUDS @ 16" O.C. PER STRUCTURAL (1) LAYER 5/8" GYP. BD., PROVIDE FIBERGLASS BACKED GYP. BD. WHERE 'WET' AREAS OCCUR INTERIOR FINISH PER SPECIFICATIONS OR PLANS MAY CONSIST OF: PAINT, CERAMIC TILE, FIBERGLASS REINFORCED PLASTIC (FRP), ETC. FIRE RATING: NOT REQUIRED SOUND RATING: NOT REQUIRED RESILIENT CHANNELS AT 24" O.C. INTERIOR WALL 2.3b NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. INSULATION AS REQUIRED PER ASSEMBLY INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. DOUBLE 3 5/8" METAL STUDS WITH AIR GAP: EXISTING TO REMAIN WHERE INDICATED ON PLAN NEW (1) LAYER 5/8" GYP. BD. EA SIDE: PROVIDE FIBERGLASS-BACKED "PAPERLESS" GYP. BD. @ 'WET' AREAS PER CALGREEN/GREENPOINT REQUIREMENTS NEW INTERIOR WALL FINISH PER SPECIFICATIONS NEW INSULATION TO REPLACE EXISTING INTERIOR WALL 2.0 NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. 3/4" (E) FIRE RATING: 1 HOUR WHERE REQUIRED SOUND RATING: 50 -54 STC MIN. 50 STC REQ'D TEST ASSEMBLY: GA FILE NO. WP 5017 INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. METAL STUDS @ 16" O.C. PER STRUCTURAL: EXISTING TO REMAIN WHERE INDICATED ON PLAN @ WALL 2.0a - USE 4" STUDS @WALL 2.0b - USE 6" STUDS (1) LAYER 5/8" GYP. BD. EA SIDE: PROVIDE FIBERGLASS-BACKED "PAPERLESS" GYP. BD. @ 'WET' AREAS PER CALGREEN/GREENPOINT REQUIREMENTS INTERIOR WALL FINISH EA SIDE PER SPECIFICATIONS INSULATION PER TITLE 24 REPORT INTERIOR WALL 2.0b NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. 2.0a FIRE RATING: NOT REQUIRED SOUND RATING: NOT REQUIRED INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. INTERIOR WALL 2.0c 4" METAL STUDS @ 16" O.C. PER STRUCTURAL: EXISTING TO REMAIN WHERE INDICATED ON PLAN (1) LAYER 5/8" GYP. BD.: PROVIDE FIBERGLASS-BACKED "PAPERLESS" GYP. BD. @ 'WET' AREAS PER CALGREEN/GREENPOINT REQUIREMENTS INTERIOR WALL FINISH PER SPECIFICATIONS INSULATION PER TITLE 24 REPORT NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. FIRE RATING: NOT REQUIRED SOUND RATING: NOT REQUIRED INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. WOOD STUDS @ 16" O.C. PER STRUCTURAL INSULATION AS REQUIRED PER ASSEMBLY FIRE RATING: NOT REQUIRED SOUND RATING: NOT REQUIRED INTERIOR WALL 2.4 NOTE: At areas of transition between different wall assemblies, continue thickest layer of substrate to provide a flush finished surface in all directions to nearest perpendicular surface (wall, ceiling, etc.) U.N.O. INSULATION NOTES: REFER TO CALGREEN, CTCAC, & ENERGY ANALYST'S REQUIREMENTS FOR INSULATION FOR ADDITIONAL INFORMATION NOT SHOWN. (1) LAYER 1/2" GLASS MAT GYP. BD 1/2" ACRYLIC PLASTER: SMOOTH TROWEL FINISH; W/ CONTROL JOINTS LOACTED PER RCP (1) LAYER 5/8" GYP. BD., PROVIDE FIBERGLASS BACKED GYP. BD. WHERE 'WET' AREAS OCCUR @ WALL 2.4a - NO 5/8" GYP. BD. H IN 1 L No. C17113 AC E O T E T S A -3.PX F 5 IL C E E IA91- FI O R N C T T E RESADC R I C C .NASL U N D Project TH E P I C T O R I A L A N D G R A P H I C E X P R E S S I O N S D I S P L A Y E D W I T H T H I S W O R K A R E C O P Y R I G H T E D U N D E R T H E L A W S O F T H E U NI T E D S T A T E S , T I T L E 1 7 , U. S . C O D E . U N D E R S E C T I O N 1 0 6 O F T H E C O P Y R I G H T A C T , TH E A R C H I T E C T S H A L L M A I N T A I N T H E E X C L U S I V E R I G H T O F T H E R E P R O D U C T I O N , D I S P LA Y OR A N Y D E R I V A T I O N O F T H I S W O R K . 12/04/17 Permit Submittal #2 12/18/17 Pricing Set 01/24/18 Permit Submittal #3 1 Wall Types - Interior 15121 A8.0.1 06/21/17 Permit Submittal #1 Ci t y o f L a Q u i n t a Ci t y o f L a Q u i n t a La Q u i n t a , C a l i f o r n i a Wa s h i n g t o n S t r e e t A p a r t m e n t s 1 1/2" = 1'-0"4Wood Stud w/ Gypsum Board 1 1/2" = 1'-0"5Wood Stud w/ Gypsum Board 1 1/2" = 1'-0"6Wood Stud w/ Gyp. Bd. w/ Ply & Res. Channel 1 1/2" = 1'-0"7Wood Stud w/ Gyp. Bd. & Res. Channel 1 1/2" = 1'-0"8Wood Stud w/ Gyp. Bd. & Res. Channel 1 1/2" = 1'-0"1Metal Stud Party Wall - Renovation 1 1/2" = 1'-0"2Metal Stud Wall - Renovation 1 1/2" = 1'-0"3Metal Stud Wall - Renovation 1 1/2" = 1'-0"10Wood Stud w/ Gypsum Board 05/21/18 Construction Set 07/12/18 RFI 066 CHASE WALLS, NONCOMBUSTIBLE 75GA-600-2009 FIRE RESISTANCE DESIGN MANUAL GA FILE NO. WP 5017 PROPRIETARY*1 HOUR FIRE 50 to 54 STC SOUND Thickness:Minimum 71/4" Approx. Weight:7 psf Fire Test:UL R3660, 06NK13008, 7-7-06; 07SR3014402, 12-18-07; 08CA14331, 6-18-08; UL Design V469 Sound Test:RAL TL06-299, 8-10-06 GYPSUM WALLBOARD, STEEL STUDS, GLASS FIBER INSULATION One layer 5/8" proprietary type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to ONE SIDE of a double row of 21/2" 25 gage steel studs 24" o.c. and not less than 1" apart with 1" Type S drywall screws 8" o.c. OPPOSITE SIDE: One layer 5/8" proprietary type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to studs with 1" Type S drywall screws 8" o.c. Optional insulation in the cavity. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Horizontal joints on opposite sides need not be staggered or backed. Lateral bracing on both sides of the wall not less than 5 feet on center vertically. Sound tested with 31/2" glass fiber insulation friction fit on one side in cavity. (NLB) PROPRIETARY GYPSUM BOARD CertainTeed Gypsum Inc.-5/8" ProRoc® Type X Gypsum Panels GA-600-2009 FIRE RESISTANCE DESIGN MANUAL and partitions) shall not be permitted to be arbitrarily used in a horizontal orientation. 14.Metal studs and runners are nominal 25 gage unless otherwise specified. 15.Greater stud sizes (depths) shall be permitted to be used in metal- or wood-stud systems. Metal studs of heavier gage than those tested shall be permitted. The assigned rating of any load-bearing system shall also apply to the same system when used as a nonload-bearing system. Indicated stud spacings are maximums. 16.Specified floor-ceiling and roof-ceiling framing sizes or truss dimensions are minimums. Greater joist or truss sizes (depths) shall be permitted to be used in metal- or wood-framed systems. Indicated joist and truss spacings are maximums.