Loading...
BWFE2024-0014DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Wall / Fence BWFE2024-0014 57755 CANTATA DRIVE 764460007 Lot 47 MB 373/59 TR 30092 RL, 47 $28,500.00 Declaration / Acknowledgement BUILDING PERMIT athita CALIFORNIA PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 01/25/2024 ISSUED DATE: 02/15/2024 Owner: Larry Liebel 391 N. Main Street, Suite 205, Corona, CA 92878 Applicant: Larry Liebel 391 N. Main Street, Suite 205, Corona, CA 92878 Contractor: Larry Liebel / 487535 391 N. Main Street, Suite 205, Corona, CA 92878 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 3/31/25 2:53 pm Page 1 of 3 BUILDING PERMIT Permit Type: Wall / Fence Permit Number: BWFE2024-0014 Property Address: 57755 CANTATA DRIVE Use of Permit 245LF OF 6' GARDEN WALLS AT NORTH, EAST WEST AND SOUTH PROPERTY LINES [PROTO II SPECIFICATIONS] 2022 CALIFORNIA BUILDING CODES. Construction Details Garden Wall Linear F000tage Total Block Wall LF 228 Other fence Linear 0 Footage Zoning RL General Plan LDR Subdivision Name TR 30092 Lot Number 47 Centerlines 92522 Legal Description Lot 47 MB 373/59 TR 30092 228 Engineering Proto II (Attach Detail) Combination Retaining 0 Wall Linear Footage Number of 0 Receptacle/Light(s) City Limits Within La Quinta Limits Lot Size 1623.15 Valuation Details Type Group Sq Ft Value Financial Information Invoice No. I N V-00004040 Fee Fee Amount Amount Paid Building Standards Administration $1.14 $1.14 Technology Enhancement Fee $8.00 $8.00 Block Wall - Each Additional 50 LF $54.93 $54.93 Block Wall - First 100 LF PC $76.28 $76.28 Block Wall - First 100 LF $61.02 $61.02 Credit Card Convenience Fee $5.33 $5.33 Digital Archiving and Records Management Fee - OTC $12.00 $12.00 Total for Invoice INV-00004040 $218.70 $218.70 Grand Total for Permit $218.70 $218.70 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 01/25/2024 0:00 01/26/2024 15:16 Building Review (1 Day) v.1 Receive Submittal 01/25/2024 0:00 01/26/2024 15:16 Permit Issuance v.1 01/26/2024 15:16 02/15/2024 14:26 Contractor / Owner -Builder Information v.1 Generic Action 01/26/2024 15:16 Verify & Invoice Fees v.1 Generic Action 01/26/2024 15:16 Ready to Issue v.1 Generic Action 01/26/2024 15:16 Verify Fee Payment & Issue Permit v.1 Generic Action 02/15/2024 14:25 Print, Attach, and Email Building Permit v.1 Create Report 02/15/2024 14:25 02/15/2024 14:26 Wall / Fence Inspections v.1 02/16/2024 0:00 Footing v.1 Inspection 02/16/2024 0:00 02/20/2024 13:06 Bond Beam v.1 Inspection Final Inspections v.1 03/12/2024 0:00 03/13/2024 14:16 Final Wall / Fence v.1 Inspection 03/12/2024 0:00 03/13/2024 14:16 Printed: 3/31/25 2:53 pm Page 2 of 3 BUILDING PERMIT Permit Type: Permit Number: Property Address: Wall / Fence BWFE2024-0014 57755 CANTATA DRIVE Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 3/31/25 2:53 pm Page 3 of 3 6" (6'-0 TO 6'-8") PROTO II - EXPOSURE C - TRENCH FOOTING 'H' MAX PER SCHEDULE 3" MORTAR COVER AROUND COUPLER AND/OR POST TENSION ROD. / SETBACK / PER ,S1.1-A2 CAP AND BLOCK PER SHEET C. STEEL PLATE TO BEAR FULLY ON CENTER WEB OR END FACE SHELL - SIZE PER SHEET C. HORIZONTAL JOINT REINFORCING TOP 2 COURSES BELOW PLATE AND AT 24" 0.C. BELOW. POST TENSION (PT) ROD SEE SHEET B FOR ROD SPECS - CENTER IN WALL. PROTO II FENCE WALL. 8" CONT FINISHED GRADE. #4 CONTINUOUS AT HOOK. CONTINUOUS CONCRETE TRENCH FOOTING. 5-0" TO DAYLIGHT MIN. 2 1 \ MAX DESIGN CRITERIA: 1. ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF MIN. 2. ALLOWABLE SOIL PASSIVE PRESSURE = 150 PCF MIN. 3. SEE SHEET B, SHEET C, AND SHEET D PRIOR TO START OF CONSTRUCTION. 4. FOR INTERMEDIATE HEIGHTS NOT SHOWN ON SCHEDULES, USE THE NEXT HIGHEST WALL HEIGHT. FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURS, INSTALL DRAINAGE BLOCK AT SWALE AT GRADE. FENCE WALL SCHEDULE AT LEVEL SOIL 'H' MAX DESIGN WIND EXP/MPH PT ROD SPACING 'D' MIN. 6'-0" C AT 110 5-4" 2'-2" 6'-8" C AT 110 4'-0" 2'-4" NOTE: SEE SHEET S1.1-A2 FOR WALLS WITHIN 50" OF TOP OF SLOPE. PROTO II STANDARDS LA QUINTA, CA no scale JOB NUMBER 19-0115-3150B TRACKING # 17-115-2325 DRAWN SAD CARUSO TURLEY SCOTT INC. www.ctsaz.com PPPPPP EEEEEE PROTO-II TM WALL SYSTEMS WWW.PROTO2.COM 3612 CALIFORNIA AVE LONG BEACH, CA 90807 ATTN: MARIO SALAZAR PH# (562) 477-8529 - msalazar@protoii.com (MAY ONLY BE INSTALLED BY APPROVED AND CERTIFIED INSTALLERS) 4., 6., AND 6' THICK POST -TENSIONED MASONRY WALLS DATE 5/7/2020 ENGR JAD PACKAGE S1.1 SHEET Al THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED W1TH WRITTEN SIGNATURE. LEGEND: �IT --o— s w— ❑❑❑❑❑❑ 0000000000 PROPERTY LINE PUBLIC UTILITY EASEMENT RICHT OF WAY (RW) TOE OF SLOPE TOE OF SLOPE SWALE SURFACE YARD DRAIN SEWER WATER EXISTING 6' BLOCK WALL EXISTING 8' BLOCK WALL 6' ONE SIDE SPLIT FACE BLOCK WALL 6' PRECISION BLOCK WALL 8' PRECISION BLOCK WALL 8' ONE SIDED SPLIT FACE MASONRY WALL • EXISTING 16"X16" SPLIT FACE MASONRY BLOCK PILASTER ▪ DOOR/GATE N AIR CONDITIONING PAD AK FIRE HYDRANT o STREET LIGHT E WATER METER SEWER LATER NOTE: ALL LOCATIONS ARE APPROXIMATE. IF THERE IS A DISCREPANCY BETWEEN THIS EXHIBIT AND THE AS —BUILT CONDITIONS OF YOUR LOT AND RESIDENCE, THE AS —BUILT CONDITIONS WILL CONTROL. NOTE: PLOTS PLANS MAY NOT SHOW CURRENT RECORD INFORMATION. REFER TO THE TITLE REPORT FOR DIMENSIONS, EASEMENTS, AND OTHER INFORMATION OF RECORD. DRY UTILITIES ARE NOT SHOWN ON THIS PLAN. 98' ❑❑❑❑❑❑❑❑❑❑❑❑❑ 28' 47 S850—BR 7 co 16' ICI BWFE2024-0014 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COM PLIANCE By: J.ANA . DATE 07/26/2024 CANTATA DRIVE NOTE: DIMENSIONS SHOWN ARE TO BUILDING — FACE AND NOT ARCHITECTURAL POP 226LF OF 6' GARDEN WALLS AT NORTH, EAST WEST AND SOUTH PROPERTY LINES [PROTO II SPECIFICATIONS] 2022 CALIFORNIA BUILDING FREE STANDING WALL CODES. SCALE: 1" =30' NOTE: GATES ARE 3 FT. FOR CALC PURPOSES WE REMOVE THIS 3 FT FROM THE DIMENSION 98 LF AT REAR PL AND 84 LF AT NORTH PL ALL OF 6' PRECISION BLOCK WALL AND 44 LF OF 6' SPLIT FACE BLOCK WALL WITH GATE AT THE SIDE YARD RETURNS. (PROTO II SPECIFICATIONS). THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE PIAZZA SERENA AUGUST 2022 WALL EXHIBIT 57755 CANTATA DRIVE LA QUINTA, CA 92253 TRACT 30092, LOT 47, PLAN 850B LOT AREA 11,671 SF SCALE 1" =30' FILE: F:\1196\Engineering\TR_30092\Wall Plan Exhibits\Phase 1\Lot 47.dwg