BWFE2024-0014DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Wall / Fence
BWFE2024-0014
57755 CANTATA DRIVE
764460007
Lot 47 MB 373/59 TR 30092
RL, 47
$28,500.00
Declaration / Acknowledgement
BUILDING PERMIT
athita
CALIFORNIA
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 01/25/2024
ISSUED DATE: 02/15/2024
Owner: Larry Liebel
391 N. Main Street, Suite 205, Corona, CA 92878
Applicant: Larry Liebel
391 N. Main Street, Suite 205, Corona, CA 92878
Contractor: Larry Liebel / 487535
391 N. Main Street, Suite 205, Corona, CA 92878
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 3/31/25 2:53 pm Page 1 of 3
BUILDING PERMIT
Permit Type: Wall / Fence
Permit Number: BWFE2024-0014
Property Address: 57755 CANTATA DRIVE
Use of Permit
245LF OF 6' GARDEN WALLS AT NORTH, EAST WEST AND SOUTH PROPERTY LINES [PROTO II SPECIFICATIONS] 2022 CALIFORNIA
BUILDING CODES.
Construction Details
Garden Wall Linear
F000tage
Total Block Wall LF 228 Other fence Linear 0
Footage
Zoning RL General Plan LDR
Subdivision Name TR 30092 Lot Number 47
Centerlines 92522 Legal Description Lot 47 MB 373/59 TR
30092
228 Engineering
Proto II (Attach Detail)
Combination Retaining 0
Wall Linear Footage
Number of 0
Receptacle/Light(s)
City Limits Within La Quinta Limits
Lot Size 1623.15
Valuation Details
Type
Group
Sq Ft Value
Financial Information
Invoice No.
I N V-00004040
Fee Fee Amount Amount Paid
Building Standards Administration $1.14 $1.14
Technology Enhancement Fee $8.00 $8.00
Block Wall - Each Additional 50 LF $54.93 $54.93
Block Wall - First 100 LF PC $76.28 $76.28
Block Wall - First 100 LF $61.02 $61.02
Credit Card Convenience Fee $5.33 $5.33
Digital Archiving and Records Management Fee - OTC $12.00 $12.00
Total for Invoice INV-00004040 $218.70 $218.70
Grand Total for Permit
$218.70 $218.70
Workflow / Inspections
Workflow Step / Action Name Action Type
Start Date End Date
Plan Check v.1 01/25/2024 0:00 01/26/2024 15:16
Building Review (1 Day) v.1
Receive Submittal 01/25/2024 0:00 01/26/2024 15:16
Permit Issuance v.1 01/26/2024 15:16 02/15/2024 14:26
Contractor / Owner -Builder Information v.1
Generic Action 01/26/2024 15:16
Verify & Invoice Fees v.1
Generic Action 01/26/2024 15:16
Ready to Issue v.1
Generic Action 01/26/2024 15:16
Verify Fee Payment & Issue Permit v.1
Generic Action 02/15/2024 14:25
Print, Attach, and Email Building Permit v.1
Create Report 02/15/2024 14:25 02/15/2024 14:26
Wall / Fence Inspections v.1 02/16/2024 0:00
Footing v.1
Inspection 02/16/2024 0:00 02/20/2024 13:06
Bond Beam v.1
Inspection
Final Inspections v.1 03/12/2024 0:00 03/13/2024 14:16
Final Wall / Fence v.1
Inspection 03/12/2024 0:00 03/13/2024 14:16
Printed: 3/31/25 2:53 pm Page 2 of 3
BUILDING PERMIT
Permit Type:
Permit Number:
Property Address:
Wall / Fence
BWFE2024-0014
57755 CANTATA DRIVE
Inspections
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Certificate of Occupancy
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Service Utilities
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Printed: 3/31/25 2:53 pm Page 3 of 3
6" (6'-0 TO 6'-8") PROTO II - EXPOSURE C - TRENCH FOOTING
'H' MAX PER SCHEDULE
3" MORTAR COVER
AROUND COUPLER
AND/OR POST
TENSION ROD.
/ SETBACK
/ PER
,S1.1-A2
CAP AND BLOCK PER
SHEET C.
STEEL PLATE TO BEAR FULLY
ON CENTER WEB OR END
FACE SHELL - SIZE PER
SHEET C.
HORIZONTAL JOINT REINFORCING
TOP 2 COURSES BELOW PLATE
AND AT 24" 0.C. BELOW.
POST TENSION (PT) ROD SEE
SHEET B FOR ROD SPECS -
CENTER IN WALL.
PROTO II FENCE WALL.
8"
CONT
FINISHED GRADE.
#4 CONTINUOUS
AT HOOK.
CONTINUOUS
CONCRETE
TRENCH
FOOTING.
5-0" TO
DAYLIGHT MIN.
2
1
\ MAX
DESIGN CRITERIA:
1. ALLOWABLE SOIL BEARING
PRESSURE = 1000 PSF MIN.
2. ALLOWABLE SOIL PASSIVE
PRESSURE = 150 PCF MIN.
3. SEE SHEET B, SHEET C, AND
SHEET D PRIOR TO START OF
CONSTRUCTION.
4. FOR INTERMEDIATE HEIGHTS
NOT SHOWN ON SCHEDULES,
USE THE NEXT HIGHEST WALL
HEIGHT.
FOR SIDEYARD RETURN WALLS
WHERE DRAINAGE SWALE
OCCURS, INSTALL DRAINAGE
BLOCK AT SWALE AT GRADE.
FENCE WALL SCHEDULE AT LEVEL SOIL
'H'
MAX
DESIGN WIND
EXP/MPH
PT ROD
SPACING
'D'
MIN.
6'-0"
C AT 110
5-4"
2'-2"
6'-8"
C AT 110
4'-0"
2'-4"
NOTE:
SEE SHEET S1.1-A2 FOR WALLS
WITHIN 50" OF TOP OF SLOPE.
PROTO II STANDARDS
LA QUINTA, CA
no scale
JOB NUMBER
19-0115-3150B
TRACKING #
17-115-2325
DRAWN
SAD
CARUSO
TURLEY
SCOTT
INC.
www.ctsaz.com
PPPPPP
EEEEEE
PROTO-II TM WALL SYSTEMS
WWW.PROTO2.COM
3612 CALIFORNIA AVE LONG BEACH, CA 90807
ATTN: MARIO SALAZAR
PH# (562) 477-8529 - msalazar@protoii.com
(MAY ONLY BE INSTALLED BY APPROVED AND CERTIFIED INSTALLERS)
4., 6., AND 6' THICK POST -TENSIONED MASONRY WALLS
DATE
5/7/2020
ENGR
JAD
PACKAGE
S1.1
SHEET
Al
THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED W1TH WRITTEN SIGNATURE.
LEGEND:
�IT
--o—
s
w—
❑❑❑❑❑❑
0000000000
PROPERTY LINE
PUBLIC UTILITY EASEMENT
RICHT OF WAY (RW)
TOE OF SLOPE
TOE OF SLOPE
SWALE
SURFACE YARD DRAIN
SEWER
WATER
EXISTING 6' BLOCK WALL
EXISTING 8' BLOCK WALL
6' ONE SIDE SPLIT FACE BLOCK WALL
6' PRECISION BLOCK WALL
8' PRECISION BLOCK WALL
8' ONE SIDED SPLIT FACE
MASONRY WALL
• EXISTING 16"X16" SPLIT FACE
MASONRY BLOCK PILASTER
▪ DOOR/GATE
N
AIR CONDITIONING PAD
AK FIRE HYDRANT
o STREET LIGHT
E WATER METER
SEWER LATER
NOTE: ALL LOCATIONS ARE APPROXIMATE. IF
THERE IS A DISCREPANCY BETWEEN THIS
EXHIBIT AND THE AS —BUILT CONDITIONS OF
YOUR LOT AND RESIDENCE, THE AS —BUILT
CONDITIONS WILL CONTROL.
NOTE: PLOTS PLANS MAY NOT SHOW CURRENT
RECORD INFORMATION. REFER TO THE TITLE
REPORT FOR DIMENSIONS, EASEMENTS, AND
OTHER INFORMATION OF RECORD. DRY UTILITIES
ARE NOT SHOWN ON THIS PLAN.
98'
❑❑❑❑❑❑❑❑❑❑❑❑❑
28'
47
S850—BR
7
co
16'
ICI
BWFE2024-0014
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE COM PLIANCE
By: J.ANA . DATE 07/26/2024
CANTATA DRIVE
NOTE: DIMENSIONS SHOWN ARE TO BUILDING —
FACE AND NOT ARCHITECTURAL POP 226LF OF 6' GARDEN WALLS AT NORTH, EAST
WEST AND SOUTH PROPERTY LINES [PROTO II
SPECIFICATIONS] 2022 CALIFORNIA BUILDING
FREE STANDING WALL CODES.
SCALE: 1" =30'
NOTE: GATES ARE 3 FT. FOR CALC PURPOSES WE REMOVE THIS 3 FT FROM THE DIMENSION
98 LF AT REAR PL AND 84 LF AT NORTH PL ALL OF 6' PRECISION BLOCK WALL AND 44 LF OF 6' SPLIT FACE BLOCK
WALL WITH GATE AT THE SIDE YARD RETURNS. (PROTO II SPECIFICATIONS). THE AREA BETWEEN THE BACK OF
CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE
CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES.
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
PIAZZA SERENA
AUGUST 2022
WALL EXHIBIT
57755 CANTATA DRIVE
LA QUINTA, CA 92253
TRACT 30092, LOT 47, PLAN 850B
LOT AREA
11,671 SF
SCALE 1" =30'