Loading...
BCPR2019-0006!� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 Ot T\4F. -- Now— � M&M Description: SILVERROCK / MONTAGE HOTEL AND SPA BUILDINGS Status: ARCHIVED Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB) Status Date: 4/26/2020 Subtype: OTHER CONSTRUCTION Applied: 10/29/2019 Address: 79179 AHMANSON LN Approved: 7/21/2021 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: AJ ORTEGA Expired: Details: SCOPE OF WORK: NEW CONSTRUCTION PLAN REVIEW OF MONTAGE HOTEL AND SPA BUILDINGS. RELATED BUT SEPERATE PERMITS ARE BEING PROCESSED FOR GRADING, STORM WATER & WET -UTILITIES AND HEALTH DEPARTMENT PERMITS RELATED TO FOOD SERVICES AND POOLS. DAYS REVIEWS ACTIONS 6 INSPECTIONS CONDITIONS CASE OPEN OPEN COMPLETED 'ilbjbjk • CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES 1ST PC COMPLETE/READY AJ ORTEGA 11/26/2019 11/26/2019 EMAIL SENT TO APPLICANT WITH 1ST REVIEW CORRECTION FOR PICK UP LIST. 2ND PC COMPLETE/READY AJ ORTEGA 1/15/2020 1/15/2020 EMAIL SENT TO APPLICANT WITH 1ST REVIEW CORRECTION FOR PICK UP LIST. 3RD PC SUBMITTAL AJ ORTEGA 3/4/2020 3/5/2020 ACCEPTED FOR REVIEW WITH EXCEPTION, REVIEWS RECEIVED CREATED. SUBMITTAL INCOMPLETE, DOES NOT INCLUDE SUPPORTING 4TH PC SUBMITTAL DOCUMENTS OR RESPONSE LIST, EMAIL SENT TO APPLICANT. AJ ORTEGA 5/11/2020 5/11/2020 RECEIVED MISSING ITEMS UPLOADED, STATUS UPDATED TO UNDER REVIEW. Printed: Wednesday, December 20, 2023 8:50:13 AM 1 of 15 CENTRALSQUARE Project Details PROJECT NUMBER City of La Quinta BCPR2019-0006 4th Submittal Review: Sent email to Teaka and Veit (cc: AJ) that H1 Electrical not consistent with revised fire life safety plan in Arch. specifically Exit Sign location and orientation. EMAIL KOHL HETRICK 5/29/2020 5/29/2020 Also advised that HS Arch sheets were not provided in Volume 2. Requested Structural Engineer to clarify 1.5 psf factor for fire sprinkler dead loading as it seems quite low. 5TH PC COMPLETE/READY EMAIL SENT TO APPLICANT REGARDING PENDING ESGIL AJ ORTEGA 7/6/2020 7/6/2020 REMARKS RESPONSE AND WITH THE PERMIT ISSUANCE FOR PICK UP CONDITIONS FOR OVERALL PROJECT. •I VAN NAME TYPE NAME ADDRESSI STATE ZIP PHONE FAX EMAIL APPLICANT GENSLER SAN DIEGO 225 BROADWAY STE SAN DIEGO CA 92101 (760)634-6543 teaka_mccarthy@gensl 100 er.com ARCHITECT GENSLER SAN DIEGO 225 Broadway Suite San Diego CA 92101 (760)634-6543 teaka_mccarthy@gensl 100 er.com CONTRACTOR R D OLSON 400 SPECTRUM CENTER IRVINE CA 92618 (760)634-6543 JRAMIREZ@RDOLSON. DR. STE 1200 COM DEVELOPER THE ROBERT GREEN COMPANY 343 4TH AVE SAN DIEGO CA 92101 (760)634-6543 JOSH @THEROBERTG RE ENCOMPANY.COM ENGINEER COFFMAN ENGINEERS 14550 FRAZEE RD SUITE San Diego CA 92108 (760)634-6543 teaka_mccarthy@gensl 600 er.com OWNER SilverRock Lodging, LLC 3551 Fortuna Ranch Rd Encinitas CA 92024 (760)634-6543 stephen@therobertgre encompany.com PRIMARY Andrew Michajlenko 225 Broadway Suite San Diego CA 92101 (760)634-6543 teaka_mccarthy@gensl CONTACT 100 er.com Printed: Wednesday, December 20, 2023 8:50:13 AM 2 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BUILDING OTHER 101-0000-42600 1 $1,500.00 $1,500.00 10/29/19 WEB4244 CREDIT GENSLER SAN DIEGO ECON CONSTRUCTION Total Paid for BUILDING OTHER CONSTRUCTION: $1,500.00 $1,500.00 HOURLY CHARGE - CITY 101-0000-42600 1 $161.00 $161.00 8/23/22 WEB12862 711870759 CREDIT 953845 ECON BUILDING STAFF HOURLY CHARGE - 101-0000-42600 2 $210.00 $210.00 8/23/22 WEB12862 711870759 CREDIT 953845 ECON ESGIL CIVIL ENGINEER Total Paid for BUILDING STAFF - PER HOUR: $371.00 $371.00 Credit Card Fee 101-0000-43505 0 $27.47 $27.47 10/29/19 WEB4244 CREDIT GENSLER SAN DIEGO ECON Total Paid for Credit Card Fee: $27.47 $27.47 101-0000-42600 ($644.00) ($644.00) 11/14/19 OFFSET OFFSET KHET 101-0000-42600 ($644.00) ($644.00) 4/16/20 OFFSET OFFSET KHET 101-0000-42600 ($212.00) ($212.00) 6/1/20 OFFSET OFFSET KHET FIRE STAFF - PER HOUR 101-0000-42420 4 $644.00 $644.00 11/14/19 DEPOSIT DEPOSIT KHET FIRE STAFF - PER HOUR 101-0000-42420 4 $644.00 $644.00 4/16/20 DEPOSIT DEPOSIT KHET FIRE STAFF - PER HOUR 101-0000-42420 3 $212.00 $212.00 6/1/20 DEPOSIT DEPOSIT KHET FIRE STAFF - PER HOUR 101-0000-42420 0 $271.00 $271.00 7/21/21 R66151 CTAAEC478 TRUST THE ROBERT GREEN AOR ACCOUNT COMPANY FIRE STAFF - PER HOUR 101-0000-42420 3 $483.00 $483.00 7/21/21 R66151 CTAAEC478 TRUST THE ROBERT GREEN AOR ACCOUNT COMPANY FIRE STAFF - PER HOUR 101-0000-42420 1.5 $241.50 $241.50 7/21/21 R66151 CTAAEC478 TRUST THE ROBERT GREEN AOR ACCOUNT COMPANY Total Paid for FIRE FEES: $995.50 $995.50 Printed: Wednesday, December 20, 2023 8:50:13 AM 3 of 15 CENTRALSQUARE Project Details PROJECT NUMBER City of La Quinta BCPR2019-0006 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY RECORDS MANAGEMENT FEE - 101-0000-42416 0 $21.00 $21.00 10/29/19 WEB4244 CREDIT GENSLER SAN DIEGO ECON MAJOR Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 10/29/19 WEB4244 CREDIT GENSLER SAN DIEGO ECON ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE DEFERRED SUBMITTAL 1ST BLDG (1WK) ESGIL 7/25/2022 8/1/2022 8/10/2022 APPROVED- 1: GLASS AND CONDITIONS GLAZING DEFERRED SUBMITTAL 1ST BLDG Al ORTEGA 7/20/2022 8/3/2022 8/23/2022 APPROVED 1: GLASS AND COMPLETE (2WK) GLAZING 1ST BLDG KURT CULVER 10/29/2019 11/19/2019 11/21/2019 REVISIONS REQUIRED COMPLETE (3WK) 1ST BLDG NS (3WK) Al ORTEGA 10/29/2019 11/19/2019 11/26/2019 REVISIONS REQUIRED SEE ATTACHED 1ST REVIEW CORRECTION LIST. Office of the Fire Marshal Review - The following corrections are required:1. Fire Deferred Submittals shall include "Private Fire Mains", "Hood Suppression Systems" and "Fuel -Fired Generator".2. All architectural floor plan sheets shall include a visual scale so as to calibrate for electronic reviews to ensure adequate Printed: Wednesday, December 20, 2023 8:50:13 AM 4 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 1ST FIRE (2WK) KOHL HETRICK 10/29/2019 11/12/2019 11/14/2019 REVISIONS REQUIRED SEE COMMENTS measurements.3. Identify the size, location and installation method for all required portable fire extinguishers in compliance with CFC 906.4. Structural Plans shall identify the Design Dead Load as including the automatic -wet fire sprinkler system components specifically.5. Plumbing plans do not appear to identify the Gas supply to the Kitchen equipment. This detail is required and identify the location of the required shutoff(s) to be tied -in to the hood suppression systems.6. Provide/improve adequate egress illumination throughout the Hotel and Spa buildings. (CBC 1008.3)a. Spa Building plans includes details on the Egress Plan (Sheet HS A01-201) of exterior illuminated EXIT signs. These were not detailed in the Electrical Plans.7. Clarify the function of the Life Safety Generator System. The Egress Lights are supported by this, but the illuminated "EXIT" signs are 90-min battery backup. What else is the Life Safety Generator System to support?8. Hotel Plans identify the provision of a "Fire Command / Security — RM 140" being provided. An actual Fire Command Center is not required for this occupancy/building (as amended by LQ Municipal Code). If such a facility is to be provided by name and function, it shall comply with LQ Municipal Code Amendments to CFC Sections 508.1.1 "Location and Access" and 508.1.8 "Fire Command Center Identification".a. Fire Command Notes on Sheet H1 E06.102 should be reviewed and corrected appropriately if there is still a desire to provide the Fire Command Center.9. For the Spa Building - Women's Garden, identify the Exit Discharge access to public way or appropriate exception conditions in compliance with CBC 1028.5.10. Interior Finish Plans shall adequately identify the classification of combustible materials to be used.a. Curtains, drapes and Printed: Wednesday, December 20, 2023 8:50:13 AM 5 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 decorative materials shall be shown to comply with CCR Title 19, Division 1, Section 3.08 — Decorative Materials. 1ST PERMIT ARMANDO 10/29/2019 10/30/2019 11/22/2019 COMPLETE TECHNICIAN (1DAY) MAGALLON 1ST PLANNING NICOLE 10/29/2019 11/12/2019 11/14/2019 PENDING DOCUMENTS Need determination on changes from SDP. (2WK) CRISTE Pending meeting with applicant. PRIOR TO BUILDING PERMIT ISSUANCE, THE 1ST PUBLIC WORKS APPROVED- FOLLOWING ITEMS ARE REQUIRED: (2WK) AMY YU 10/29/2019 11/12/2019 11/12/2019 CONDITIONS - APPROVED PRECISE GRADING PLAN - PAD ELEVATION CERTS - COMPACTION REPORT 2ND BLDG KURT CULVER 12/16/2019 1/2/2020 1/15/2020 REVISIONS REQUIRED SEE ATTACHED 2ND REVIEW CORRECTION LIST. COMPLETE (2WK) 2ND BLDG NS (2WK) AJ ORTEGA 12/16/2019 1/2/2020 1/15/2020 REVISIONS REQUIRED SEE ATTACHED 2ND REVIEW CORRECTION LIST. Printed: Wednesday, December 20, 2023 8:50:13 AM 6 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 2ND FIRE (3WK) KOHL HETRICK 12/16/20191 12/30/2019 1 12/30/2019 1 REVISIONS REQUIRED 2ND SUBMITTAL - Office of the Fire Marshal Review - The following corrections are required: 1) Structural Plans shall identify the Design Dead Load as including the automatic -wet fire sprinkler system components specifically. The Dead Load factor is not identified on the plan sheets, specifically sheet MH S00.101. Nor was I able to decipher the Dead Load in the Structural Calculations. 2) Electrical Plans show some updates referencing Emergency Egress Illumination Plan on Sheets H1 E05.101 & 102 for the Hotel Building. The Delta Cloud areas that show adequate coverage were not otherwise updated on the Fixture "Lighting Schedule" on Sheet E00.002 nor on the Plan Sheets. The detailed fixtures should be updated to confirm their emergency power supply as being from the Emergency Generator. Update all Electrical Plan Sheets as affected. 3) Provide/improve adequate egress illumination throughout the Spa buildings. (CBC 1008.3) a. Spa Building Public Restrooms exceed 300 square feet and require Emergency Egress Illumination. 4) Spa Building plans includes details on the Egress Plan (Sheet HS A01-201) of exterior illuminated EXIT signs (Treatment Room Yard Gate, Garden areas —A-5 occupancies?, etc.). These were not detailed in the Electrical Plans. 5) Interior Finish Plans shall adequately identify the classification of combustible materials to be used. a. Curtains, drapes and decorative materials shall be shown to comply with CCR Title 19, Division 1, Section 3.08 — Decorative Materials. (*Response to corrections noted to see "volume 3 Interior Drawings for Finish Plans and Schedules" but this was not attached/provided) Printed: Wednesday, December 20, 2023 8:50:13 AM 7 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER " BCPR2019-0006 City of La nuinta Ot T\4F. 2ND PLANNING NICOLE 12/16/2019 1/2/2020 1/2/2020 PENDING DOCUMENTS Applicant to file MBA for all project components (2WK) CRISTE prior to Planning OK of building plans. PRIOR TO BUILDING PERMIT ISSUANCE, THE 2ND PUBLIC WORKS APPROVED- FOLLOWING ITEMS ARE REQUIRED: (2WK) AMY YU 12/16/2019 1/2/2020 12/17/2019 CONDITIONS - APPROVED PRECISE GRADING PLAN - PAD ELEVATION CERTS - COMPACTION REPORT 3RD BLDG KURT CULVER 3/4/2020 3/18/2020 4/1/2020 REVISIONS REQUIRED SEE ATTACHED 3RD REVIEW ESGIL CORRECTION COMPLETE (2WK) LIST. 3RD BLDG NS (2WK) AJ ORTEGA 3/4/2020 3/18/2020 4/2/2020 REVISIONS REQUIRED SEE ATTACHED 3RD REVIEW CORRECTION LIST. 3RD SUBMITTAL - Office of the Fire Marshal Review - 3RD Submittal included a collection of 4 Volumes of plan sets.The following corrections are required:1) All "Drawing Index" pages provided had notable or significant errors. *See attachments for thorough analysis of errors.a) Volume 4 did not include a specific Drawing Index for reference.b) Several additional (new) pages were added.c) Several individual and collections 3RD FIRE (1WK) KOHL 3/3/2020 3/10/2020 4/16/2020 REVISIONS REQUIRED SEE NOTES of sheets were noted in the Index but were not HETRICK included anywhere in the submittal.2) H1 Electrical Plans were not provided.3) HS Plumbing Plans were not provided.4) HS Interiors Plans were not provided.5) Sheet MH G00.001 requires the following cleanup:a) Under "Fire Dept. Submittals & Permits" - item 3. is provided but is not appropriate in this location.b) Under "Deferred Submittals" - Item 1 needs to correctly reference the year edition of CFC and NFPA 13 - correct 2010 to 2016. MBA Submitted but not complete. Planning must 3RD PLANNING NICOLE complete MBA prior to approval of plan set. (2WK) CRISTE 3/4/2020 3/18/2020 3/17/2020 PENDING DOCUMENTS MBA Submitted but not complete. Planning must complete MBA prior to approval of plan set. Printed: Wednesday, December 20, 2023 8:50:13 AM 8 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 PRIOR TO BUILDING PERMIT ISSUANCE, THE 3RD PUBLIC WORKS APPROVED- FOLLOWING ITEMS ARE REQUIRED: (2WK) AMY YU 3/4/2020 3/18/2020 3/16/2020 CONDITIONS - APPROVED PRECISE GRADING PLAN - PAD ELEVATION CERTS - COMPACTION REPORT 4TH BLDG COMPLETE (2WK) KURT CULVER 5/11/2020 5/26/2020 6/1/2020 REVISIONS REQUIRED SEE ATTACHED 4TH REVIEW CORRECTION LIST. 4TH BLDG NS (2WK) AJ ORTEGA 5/11/2020 5/26/2020 6/1/2020 REVISIONS REQUIRED SEE ATTACHED 4TH REVIEW CORRECTION LIST. 4th REVIEW FIRE COMMENTS: 1) Volume 1 - H1 Electrical Plans (not provided in 3rd Submittal) are not consistent with the Life Safety Architectural details on H1 A01.201 in particular to Exit Sign placement and directional. *1 did like the additional ones added on the E plans, but there is certainly some key one's that were missed or are not correctly orientated. 4TH FIRE (2WK) KOHL 5/11/2020 5/26/2020 6/1/2020 REVISIONS REQUIRED CORRECTIONS IN HETRICK NOTES 2) Volume 2 - HS Architectural Plan sheets were not included. Just S, M, E & P sheets were provided. 3) Structural Calcs are referencing Dead Load capacities with itemized Fire Sprinkler loading of 1.5 psf. This seems low to me for water -filled steel pipe systems. Please help me in getting clarification from the Structural Engineer on their resource for this 1.5 psf factor. SUBMITTAL INCOMPLETE, DOES NOT INCLUDE 4TH PERMIT TECH (1 SUPPORTING DOCUMENTS OR RESPONSE LIST. DAY) AJ ORTEGA 5/11/2020 5/12/2020 5/11/2020 COMPLETE MISSING ITEMS UPLOADED, REVIEW CREATED STATUS UPDATED TO COMPLETE. 4TH PLANNING (2WK) NICOLE CRISTE 5/7/2020 5/17/2020 5/8/2020 READY FOR APPROVAL MBA Complete. Plans are consistent with MBA. Printed: Wednesday, December 20, 2023 8:50:13 AM 9 of 15 CENTRALSQUARE Project Details PROJECT NUMBER City of La Quinta BCPR2019-0006 5TH BLDG KURT CULVER 6/17/2020 7/1/2020 7/1/2020 APPROVED- PENDING CONFIRMATION WITH ESGIL REVIEWER COMPLETE (2WK) CONDITIONS REGARDING REMARKS COMMENT. 5TH BLDG NS (2WK) AJ ORTEGA 6/17/2020 7/1/2020 7/6/2020 APPROVED- PENDING CONSULTANT COMMENT AND OTHER CONDITIONS PERMIT ISSUANCES CONDITIONS. 5TH FIRE (2WK) KOHL 6/17/2020 7/1/2020 7/2/2020 READY FOR APPROVAL SEE ATTACHMENTS HETRICK FOR COA Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2019-0006 - 1ST DOC 11/26/2019 AJ ORTEGA 1ST REVIEW REVIEW CORRECTION 0 CORRECTION LIST LIST.pdf BCPR2019-0006 - 2ND 2ND SUBMITTAL DOC 12/16/2019 AJ ORTEGA STRUCTURAL SUBMITTAL 0 STRUCTURAL RESPONSES RESPONSES.pdf BCPR2019-0006 - 2ND DOC 1/15/2020 AJ ORTEGA 2ND REVIEW REVIEW CORRECTION 0 CORRECTION LIST LIST.pdf BCPR2019-0006 - 3RD DOC 4/2/2020 AJ ORTEGA 3RD REVIEW ESGIL REVIEW ESGIL 0 CORRECTION LIST CORRECTION LIST.pdf BCPR2019-0006 - 3RD DOC 4/2/2020 AJ ORTEGA 3RD REVIEW REVIEW CORRECTION 0 CORRECTION LIST LIST.pdf DOC 4/2/2020 AJ ORTEGA CVWD APPROVAL BCPR2019-0006 - CVWD 1 (HOTEL) APPROVAL (HOTEL).pdf DOC 4/2/2020 AJ ORTEGA CVWD APPROVAL BCPR2019-0006 - CVWD 1 (POOL) APPROVAL (POOL).pdf DOC 4/2/2020 AJ ORTEGA CVWD APPROVAL (SPA) BCPR2019-0006 - CVWD 1 APPROVAL (SPA).pdf " CENTRALSpUARE Printed: Wednesday, December 20, 2023 8:50:13 AM 10 of 15 � !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2019-0006 - DOC 5/11/2020 AJ ORTEGA HEALTH DEPARTMENT HEALTH DEPARTMENT 1 APPROVAL APPROVAL.pdf BCPR2019-0006 - 4TH DOC 6/1/2020 AJ ORTEGA 4TH REVIEW REVIEW CORRECTION 0 CORRECTION LIST LIST.pdf BCPR2019-0006 - 5TH DOC 6/17/2020 AJ ORTEGA 5TH SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 1) (PART 1).pdf BCPR2019-0006 - 5TH DOC 6/17/2020 AJ ORTEGA 5TH SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 2) (PART 2).pdf BCPR2019-0006 - 5TH DOC 6/17/2020 AJ ORTEGA 5TH SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 3) (PART 3).pdf BCPR2019-0006 - 5TH DOC 6/17/2020 AJ ORTEGA 5TH SUBMITTAL SUBMITTAL APPLICANT 0 APPLICANT RESPONSES RESPONSES.pdf BCPR2019-0006 - PLAN DOC 8/23/2022 AJ ORTEGA PLAN SET - PART 1 SET - PART 1 1 (APPROVED) (APPROVED).pdf BCPR2019-0006 - PLAN DOC 8/23/2022 AJ ORTEGA PLAN SET - PART 2 SET - PART 2 1 (APPROVED) (APPROVED).pdf BCPR2019-0006 - STRUCTURAL STRUCTURAL DOC 8/23/2022 AJ ORTEGA CALCULATIONS - CALCULATIONS - 1 SUPPLEMENTAL (APPROVED) SUPPLEMENTAL (APPROVED).pdf Printed: Wednesday, December 20, 2023 8:50:13 AM 11 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2019-0006 - STRUCTURAL DOC 8/23/2022 AJ ORTEGA CALCULATIONS STRUCTURAL 1 (APPROVED) CALCULATIONS (APPROVED).pdf BCPR2019-0006 - DEF DEF SUB 1 - GLASS AND DOC 8/23/2022 AJ ORTEGA GLAZING DESIGN SUB 1 - GLASS AND 1 (APPROVED) GLAZING DESIGN (APPROVED).pdf BCPR2019-0006 -1ST 1ST SUBMITTAL DOC 10/29/2019 EtrakitContractor STRUCTURAL SUBMITTAL 0 STRUCTURAL CALCULATIONS CALCULATIONS.pdf BCPR2019-0006 - 1ST DOC 10/29/2019 EtrakitContractor 1ST SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 3) (PART 3).pdf BCPR2019-0006 - 1ST DOC 10/29/2019 EtrakitContractor 1ST SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 1) (PART 1).pdf BCPR2019-0006 - 1ST DOC 10/29/2019 EtrakitContractor 1ST SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 2) (PART 2).pdf BCPR2019-0006 - 2ND DOC 12/13/2019 EtrakitContractor 2ND SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 1) (PART 1).pdf BCPR2019-0006 - 2ND DOC 12/13/2019 EtrakitContractor 2ND SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 2) (PART 2).pdf BCPR2019-0006 - 2ND 2ND SUBMITTAL SUBMITTAL DOC 12/13/2019 EtrakitContractor STRUCTURAL STRUCTURAL 0 CALCULATIONS (SUPPLEMENTAL) CALCULATIONS (SUPPLEMENTAL).pdf Printed: Wednesday, December 20, 2023 8:50:13 AM 12 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2019-0006 - 2ND DOC 12/13/2019 EtrakitContractor 2ND SUBMITTAL SUBMITTAL 0 COMMISSIONING PLAN COMMISSIONING PLAN.pdf BCPR2019-0006 - 2ND DOC 12/16/2019 EtrakitContractor 2ND SUBMITTAL SUBMITTAL APPLICANT 0 APPLICANT RESPONSES RESPONSES.pdf BCPR2019-0006 - 3RD 3RD SUBMITTAL DOC 3/3/2020 EtrakitContractor STRUCTURAL SUBMITTAL 0 STRUCTURAL NARRATIVE NARRATIVE.pdf BCPR2019-0006 - 3RD 3RD SUBMITTAL DOC 3/3/2020 EtrakitContractor ARCHITECTURAL SUBMITTAL 0 ARCHITECTURAL NARRATIVE NARRATIVE.pdf BCPR2019-0006 - 3RD DOC 3/3/2020 EtrakitContractor 3RD SUBMITTAL SUBMITTAL APPLICANT 0 APPLICANT RESPONSES RESPONSES.pdf BCPR2019-0006 - 3RD DOC 3/3/2020 EtrakitContractor 3RD SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 1) (PART 1).pdf BCPR2019-0006 - 3RD DOC 3/3/2020 EtrakitContractor 3RD SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 3) (PART 3).pdf BCPR2019-0006 - 3RD DOC 3/3/2020 EtrakitContractor 3RD SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 2) (PART 2).pdf BCPR2019-0006 - 3RD DOC 3/3/2020 EtrakitContractor 3RD SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 4) (PART 4).pdf Printed: Wednesday, December 20, 2023 8:50:13 AM 13 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2019-0006 - 4TH DOC 5/8/2020 EtrakitContractor 4TH SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 1) (PART 1).pdf BCPR2019-0006 - 4TH DOC 5/8/2020 EtrakitContractor 4TH SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 3) (PART 3).pdf BCPR2019-0006 - 4TH DOC 5/8/2020 EtrakitContractor 4TH SUBMITTAL PLAN SUBMITTAL PLAN SET 0 SET (PART 2) (PART 2).pdf BCPR2019-0006 - 4TH DOC 5/11/2020 EtrakitContractor 4TH SUBMITTAL FIRE SUBMITTAL FIRE 0 RESPONSES RESPONSES.pdf BCPR2019-0006 - 4TH 4TH SUBMITTAL DOC 5/11/2020 EtrakitContractor STRUCTURAL SUBMITTAL 0 STRUCTURAL CALCULATIONS CALCULATIONS.pdf BCPR2019-0006 - 4TH 4TH SUBMITTAL SUBMITTAL DOC 5/11/2020 EtrakitContractor STRUCTURAL STRUCTURAL 0 CALCULATIONS (SUPPLEMENTAL) CALCULATIONS (SUPPLEMENTAL).pdf BCPR2019-0006 - 4TH DOC 5/11/2020 EtrakitContractor 4TH SUBMITTAL SUBMITTAL APPLICANT 0 APPLICANT RESPONSES RESPONSES.pdf 4TH SUBMITTAL - PATH DOC 5/20/2020 EtrakitContractor OF TRAVEL PA 2 POT and Park.pdf 0 INFORMATION BCPR2019-0006 - DEF DEFERRED SUBMITTAL 1 DOC 7/20/2022 Etrakit Contractor - 1ST SUBMITTAL GLASS SUB 1 - 1ST SUBMITTAL 0 GLASS AND AND GLAZING GLAZING.pdf Printed: Wednesday, December 20, 2023 8:50:13 AM 14 of 15 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2019-0006 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED Approved- BCPR2019- Approved- BCPR2019- DOC 8/10/2022 ESGIL 0006 - DEF SUB 1- 1ST 0006 - DEF SUB 1- 1ST 0 SUBMITTAL GLASS AND SUBMITTAL GLASS AND GLAZING.pdf GLAZING.pdf BCPR2019-0006 - 2ND DOC 1/15/2020 JAKE FUSON 2ND REVIEW ESGIL REVIEW ESGIL 0 COMMENTS COMMENTS.pdf BCPR2019-0006 - 1ST 1ST REVIEW ESGIL DOC 1/15/2020 JAKE FUSON INVOICE (NO FEES REVIEW ESGIL INVOICE 0 (NO FEES INCLUDED) INCLUDED).pdf BCPR2019-0006 - 1ST DOC 11/22/2019 KURT CULVER 1ST REVIEW ESGIL REVIEW ESGIL 0 CORRECTION LIST CORRECTION LIST.doc BCPR2019-0006 - 1ST DOC 11/14/2019 KOHL HETRICK 1ST REVIEW OFM REVIEW OFM 0 CORRECTION LIST CORRECTION LIST.docx 3RD SUBMITTAL - DOC 4/16/2020 KOHL HETRICK DRAWING INDEX MH G01.001.pdf 0 ERRORS BCPR2019-0006 - 3rd 3rd REVIEW FIRE DOC 4/16/2020 KOHL HETRICK REVIEW FIRE 0 CORRECTION LIST COMMENTS.pdf BCPR2019-0006 - FIRE DOC 7/2/2020 KOHL HETRICK FIRE CONDITIONS OF CONDITIONS OF 1 APPROVAL APPROVAL.pdf Printed: Wednesday, December 20, 2023 8:50:13 AM 15 of 15 CENTRALSQUARE CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT �Cv SHAWN C. NEWMAN - FIRE CHIT OFFICE OF THE FIRE MARSHAL — LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org July 2, 2020 Gensler San Diego 225 Broadway Ste 100 San Diego, CA 92101 Re: New Buildings - Fire Plan Review — MONTAGE HOTEL, SPA & POOL STRUCTURES BCPR2019-0006 / 52-000 SILVERROCK WAY, LA QUINTA, CA 92253 The building plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Fire Department approval is based upon the 2016 CBC requirements for A-2, A-3 & B occupancies. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy, without further review and approval. ACCESS Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with the California Fire Code, Riverside County Ordinance 460, Riverside County Ordinance 787 and Riverside County Fire Department Standards. 1) Certain designed areas will be required to be maintained as fire lanes and will require approved signs and/or stenciling in red with CVC 22500.1 conspicuously posted. 2) Vehicle access gates shall be provided with KNOX Box, Padlock or Key -switch access. Automatic gates shall also have Opticom IR receivers. 3) Approved street signs shall be installed and visible. 4) No Traffic Calming Devices shall be installed. WATER 1) The Fire Department is required to set a minimum fire flow for the construction of all buildings using the procedure established in the 2016 CFC. a. MONTAGE HOTEL: A fire flow of 2,250 gpm flow @ 20 psi residual pressure from a minimum of 2 fire hydrants flowing simultaneously/cumulatively for a 2-hour duration. This water supply must be available within 400-feet of the project before vertical construction begins. i. Fire Flow requirement based on currently proposed 28,000 square feet structure of type V-B construction. A 50% reduction due to the provision of required fire sprinkler system has been included. b. MONTAGE SPA: A fire flow of 1,875 gpm flow @ 20 psi residual pressure from a minimum of 2 fire hydrants flowing simultaneously/cumulatively for a 2-hour duration. This water supply must be available within 400-feet of the project before vertical construction begins. i. Fire Flow requirement based on currently proposed 20,000 square feet structure of type V-B construction. A 50% reduction due to the provision of required fire sprinkler system has been included. MONTAGE POOL STRUCTURES: A fire flow of 1,000 gpm flow @ 20 psi residual pressure from a minimum of 2 fire hydrants flowing simultaneously/cumulatively for a 2-hour duration. This water supply must be available within 400-feet of the project before vertical construction begins. i. Fire Flow requirement based on currently proposed 4,000 square feet structure of type V-B construction. A 50% reduction due to the provision of required fire sprinkler system has been included. 1) Applicant and/or developer shall separately submit off -site water system plans to the Fire Department office for review. Plans must be signed by a registered Civil Engineer and/or water purveyor prior to Fire Marshal review and approval. Mylar will be signed by the Fire Marshal after review and approval. DEFERRED SUBMITTALS REQUIRED 1) PRIVATE FIRE MAIN — System plans in compliance with NFPA 24 must be submitted to the Fire Department for review and approval. Hydraulic Calculations are required. Permit fees will be required. 2) FIRE SPRINKLER SYSTEM - Install a complete fire sprinkler system per NFPA 13. System plans must be submitted to the Fire Department for review and approval. The plans and documents shall include certification and signature from the Structural Engineer attesting that the plans are compliant with structural loading and design for the building. Permit fees will be required. 3) FIRE ALARM/MONITORING SYSTEM - Install a MANUAL fire alarm system as per NFPA 72 required by the California Building Code, California Fire Code and designed in accordance with adopted standards. A C-10 licensed contractor must submit plans to the Fire Department office for review and approval prior to installation. Permit fees will be required. 4) KITCHEN HOOD SUPPRESSION SYSTEM - A UL 300 hood/duct fire extinguishing system must be installed over the cooking equipment as required by the California Fire Code, California Mechanical Code and adopted standards. System plans must be submitted to the Fire Department for review, along with current plan check/inspection fee. Permit fees will be required. 5) ABOVEGROUND HAZARDOUS CHEMICAL STORAGE TANK(S) — Plans and specifications shall be submitted to the Fire Department for review and approval. Permit fees will be required. (This permit type includes fuel -fired generators) 6) REFRIGERATION EQUIPMENT — An operational permit is required to operate a mechanical refrigeration unit or system regulated by Chapter 6 in the CFC. (>220-pounds Class Al refrigerant / >30-pounds all other classes) System plans must be submitted to the Fire Department for review. Permit fees will be required. PRIOR TO FINAL 1) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. Building address numbers shall be a minimum of 12". Minimum 6" tall suite addressing shall be provided to both the front and rear entrances. All addressing must be legible and of a contrasting color with the background to be visible from the street at all hours. 2) Install Knox Key Lock box, mounted not higher than 6-feet above grade at approved location. Provide keys to the tenant space (all tenants), utility rooms and elevator services for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. 3) Submit flame-retardant certification(s) by applicator or manufacturer, along with CSFM Listing, for all decorative materials used in this facility. Samples of flame-retardant material(s) may be required for flame spread testing. All required treated materials must have a current CSFM approval tag affixed to each item or panel. (Prior to building final inspection) 4) Install portable fire extinguishers per Title 19, but not less than 2A1OBC in rating, at the approved locations. Additional placements may be required at time of inspection. 5) Occupancies storing or using significant volumes of hazardous materials shall appropriately display the required NFPA 704 Hazard Placard on the exterior access to the yards, buildings and rooms where the hazardous materials is located. 6) Applicable room door(s) shall be posted "ELECTRICAL", "FACP", "FIRE RISER" and "ROOF ACCESS" on the outside of the door so it is visible and in a contrasting color. 7) Room occupancy load, as approved by the Building Official, shall be posted in a conspicuous place near the main exit from the room(s). The location shall be approved by the Fire Department office. Posting shall be by means of an approved durable sign having a contrasting color from the background to which it is attached. The owner shall maintain signs in a legible manner. No person shall deface, remove or change the occupant load on the sign except as authorized by the Building Official and/or Fire Department office. (Prior to building final inspection) 8) Illuminated Exit Signage and Egress Illumination placement and functional test will be witnessed by OFM Fire Inspector. 9) Fire rated assemblies shall be maintained in compliance with applicable codes and industry standards. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist �J,IATFR COACHELLA VALLEY WATER DISTRICT O�STRIGC P.O. BOX 1058, COACHELLA, CALIFORNIA 92236 (760) 398-2651 INVOICE Date:3/23/2020 SUBJECT: PM 37207, SILVERROCK, 25000 SILVERROCK WAY, LA QUINTA, "MONTAGE HOTEL SPA" (SOURCE CONTROL ONLY) ROBERT GREENE Project: 20-10874 3551 FORTUNA RANCH RD. Project Date: 2/26/2020 Amount Due: $50.00 ENCINITAS, CA 92024 GEO: 06-07-05-3 Planner: SARA LOPEZ TO INSURE PROPER CREDIT, PLEASE RETURN THIS PORTION WITH REMITTANCE AND INCLUDE THE PROJECT ON YOUR CHECK t Fee Type Description Charge Amount Total Amount 1.00 SA APP/WAIVER FEE SOURCE CNTRL 1 $60.001 $50.00 $50.00 Paid$ r — MHI)% Development Services DepaWent MAR 2 5 202D Coachella Valiayy Water District 75-515 Hovely Lane East Palm Desert, CA 92211 SUBJECT: PM 37207. SILVERROCK. 25000 SILVERROCK WAY, LA QUINTA. 'MONTAGE HOTEL SPA" (SOURCE CONTROL CN'_Y) COACHELLA VALLEY WATER DISTRICT P.O. BOX 1058, COACHELLA, CALIFORNIA 92236 (760) 398-2651 Pagel COACHf LLA VALLEY NVA'rER DISTRICT Hovicv Lane East q75-515 Palrn Deserl, California 92211 (760) 398-2651 APPLICATION FOR WASTEWATER SOURCE CONTROL PLAN APPROVAL \PI'I.K'•\`1T 1;0 nit tlu, fhnn a nh a cop} of a SCALED plot plan I . '•20' W I' 40' SCALE) dra\+n to Mstiio spec ticaii s A nonrelundahlc riling fee t+ rcqurnal i,I,Lti i'i; aPPtnau,m i, .uurnitiml Cliccl musi be made payable to the Cwche'la t•alley Wait! District .Appro+ai of thtc 4p;1, rahan shall remain t aad t •t a P;nrts1 niv in nccrd ant: ! I l � c.t: from dale of payment NOTEs AL L USERS DISCHARGuNG FAT, OIL, AND/OR GlMtSE, LOCATED R4 A MULT1. SUM BVIL.014G WILL REQUIRE A SEPARATE LATERAL bPP.THE MALNSFIVER LINE FOR GREASEimrERCEPTOR CONNECTION C%'%%*D Source Control will insprrt the rspmed cressr plumbirg and the installed interceptor Please call (7601 398-2661 \3536 JB hours in adunce it, schedule Ins eetion4s). Apenr. Contoeior, Contac' Penor Addrns City State Zip Tc1crhvnc A,drew M.criallen►o 225 8,oadway Smile 10C San D'opo CA 92101 (619; 223 3131 TrkPtvnnr -- ttuber Adders+ y - Cry Ha:: Z' Robert Green 3551 Fortuna Rance Rand Encinitas CA 02024 1 (760) 634 65e3 lob Su: Adams% City Zip 25.000 SilverRock Way La Oulnta 92253 Dus:reu T57te Dmrf $tutne++ As (. Ot-sTkj-L- SdvetAOCKLodOingLrC NOTE: NO PLANS WILL BE APPROVED UNTIL T1i1S APPLICATION IS COMPLETF AN') PLAN• CHECK FEES ARE PAID Tv a or Construction etc ❑ Remodel Hours of Upcmunn -Ea—m-10pm Cnnl ng'rowerts) ❑ For Vehicle Serc ice For Food Service O Wand Bays ❑ Trench Itrains i Ft; )i Water Softener ❑ G,irbase Crmders) n Digester{; D Roll over ❑ Seance bay(s) _ Niultiscn•tee (reusahic) 20 °. Single Scntce dlsP(3sabL-)_80 ❑ Tunncl(s) ❑ Pans Washer Sating Capacity Internal Fxtcrnal 50 CJ Spill Containment (Solvent O Aqucous 0 1 Sealing with S isrers or Healers 17 Hydraulic Lifts ❑Work Sink(s) Bat Seaun Bnr Seavyip vnih Fo,.d Scn ice 0�VNFR/REPRESENTATWE DECLARATION I cemfv lha. I have rod the entire application and slate that all informatr in :s carrccl understand that the fee 2motint is based on my declaration of information or thin futrn and tttai utcorreci inlurniatiwt is grounds for reje::r. • :,l Ili- submitied plans 1 also understand that plans may be discarded if nor ptcked up Nvillnn stitty 160) days of appio+•ai. or raum and that m• Die ti ter i inspection of my emahlishmeni will be coad ictrd until nil requested infonnaiajr• has been recnted and plane hate been arpro-d 5ignai.irc ���— Date t /ti /2t! FOR D1STRICTME ONLY No. ofSvornts I Type ofSystertt(c1 Pretreatment F.Rutpmrnl --- 0 Grease inierLepint lnlercepiut \failed ❑ Nesc ❑ Existing ❑ SandlOil U ® Connect to Sc%c:r ❑ Addition 0 i-int Trap ❑ Point nrCornectwN Sample Stuituo ❑ Feplacemrni 0 C'lonficr ❑ Utgesicris. r .,--- Size as REMARKS: — - - -- 'Discharges containing fats, oils, or grease (FOG) must be routed to Montage Hotel or Montage pool rease_interceptors. 'No saltregenerativt-svater softeners allowed in CY.-WD jurisdic-doni only exchangeable bottles systems are perm ssible.— ---- - Thisappheatton ]/n� /� IDcond,unr•,ll. ;,rhrn•c L7 Aprre..ed F7 /,2t-L/ -5 1, V LI ) 'Scc Rcmar l a r es Q he.t S notate- I)atr 31a� ab Date 3 Zs/a.Q2c� �NATER COACHELLA VALLEY WATER DISTRICT O�STFt1C� P.O. BOX 1058, COACHELLA, CALIFORNIA 92236 (760) 398-2651 INVOICE Date:3/23/2020 SUBJECT: PM 37207, SILVERROCK, 25000 SILVERROCK WAY, LA QUINTA, "MONTAGE POOL" (SOURCE CONTROL ONLY! ROBERT GREEN Project: 20-10878 3551 FORTUNA RANCH RD. Project Date: 2/26/2020 Amount Due: $50.00 ENCINITAS, CA 92024 GEO: 06-07-05-3 Planner: SARA LOPEZ TO INSURE PROPER CREDIT, PLEASE RETURN THIS PORTION WITH REMITTANCE AND INCLUDE THE PROJECT ON YOUR CHECK SUBJECT: PM 37207, SILVERROCK. 25000 SILVERROCK WAY, LA OUINTA 'MONTAGE POOL" (SOURCE CONTROL ONLY) COACHELLA VALLEY WATER DISTRICT P.O. BOX 1058, COACHELLA, CALIFORNIA 92236 (760) 398-2651 Pagel COACHELLA VALLEY WATER DISTRICT Hovler' Lane Enst zATI75-515 Palm Desert, California 92211 (11601 198-'_651 aPPL1C,010N FOR 1VASI EWATER SOURCE CONTROL PLAN APPROVAL ",!':'I I!' 1'+'I,',uhnit, r,:. a tth a copy of a SCALED plot ptan i t" 20' to 1' 40' SCALf) draaT to Disinct ,`.ling; lee o ,, qrt :d .. tin, It`:.,r•i%11.. 'V1 , . thrrimcd Cbeck must be malt p;iyablc to the Lcarheda Folk} tt'ater Drsm,"l Appao%zi of Inic app'Icauon shall remain valid I. - NOTE. LLL USERS DISCILARGING FAT. On., ANDIOR GREASE, LOCATED tN A Dtlil,Tl- SIIIII SUII.UING ► ILL REQUIRE A SEPA"I E td, VE;RAL OF'FTRP MAIN SEWER -LINE FUR GUASE t*'TERIUMOR CONNE(MON. e'V7vn Source Control wil: inspect the exposed Cruse pluathinr sac the installed inteireptor Plente call 4"6t1! 19A•2tibl X%536 aA hours In adaerre to schedule tos eetion's 1f;:m i amraaa+. Come: Putar AdJrea ,:r• 5,n: : q TC:ptw,r.: Andrew Muhalleni- 225 Broadway 5:r to 100 San Diego CA 92101 :619) 223-3 , 31 U.,Ttcr I 11JJratt — --- - lrtj iutr :,p Tcltphnx Robert Green 3551 Fortuna Rancn Road Enurifas CA 92024 (760) 634.6543 Joa sue nJetett - c,t :,r 25-000 Sllver%zk Way La 0:un1a 92253 Aty..:u Type IromE Iluvn:n M j�lptti �f L. Pc C SdJerRock Lodging LrC NOTE: NO PLANS ")LL BE APPROVED UNT11. TIM APPLICATION IS COMPLETE AM) IT kX (.'NECK FEES AIM PAIL). If pe of Construction: %Nett D P.em^dc, l lours oe Opaant,n £am - 1:am Ceahr,p lowerfst D For Vehicle Sersicc: TFor Food Service- ❑ Wand Sops C T.coch harm (_-_ n i ❑ Water Saf*cncr C .-nrbabc C,nndcr(s: J thgesicrtsl C) Roll ose: Cl Ser-Ice baclsl _ Muluscmice iretlsabW 20 "." Single 5cnice ldisposablc) ❑ Tunncli i'r ❑ Pans Wachc• Scating i ap�an Internal External -.� _-- ❑ Spill t_entatnrricrn fct+:v^nt ❑ Aqueous D } _I Seating %v:lh Mivvii o. heater,. D litdcaulic Lift(s) Ow"rk Emkri) Bar Scaling Bar Scalirg with Focd Senice n1L NEP. P.LFR65L\T+1TI'+'[ DECI-AriATM- I ecnify that I ft:we rrad :hr entire applicalion Line atnir th-i all :nfc,mtahor, +. curer undtrsfand that the fee amuuni :s baLe,4 on m} decl:raitc•r of mrormatu•n or- this forrn and due irim"eci informwim. is ground- for rejretinn of t!,c ,abriwict! plan. 1 aisu understand tial plain •nat fir d,sca,decl if no, i t ked up within sixty rL•ri; day-, of apprnta: nr Teinrn and that nn I),;rnr1 W specitun or rn t• c%utoltAmicw it•i li he cotldbcictl until all tr;luesicd tnlumvion hag been t::cit rd and plan, lwmc hcen appr i ee FOR DISTRICT tiSETOTLY _ r ::I 5' ::cm,r. y Piclrcatrnmi F.atnpmci l --- - 10 Ctrcasc Inir,:rr or El C•cn:- Inlerccptn- %\ an cd ® ❑ Sand%Oil 1 D Cuanr_i w 5et,c• C -Ndd±uoc G Lin Trap ❑ I a:n• of Connccl:on Sarnril: Siaaor. CJ kcplaccmrnl G ; „•,li-• O F.•tgrr:cn,s! T_ SI!•e 750 g3li varhsasnplebox RF.Ai 1ItkS: '750 gal -grease -interceptors must -have its own sample.box._- "Discharges containing fats, oils, and grease must be routed to grease interceptors, examples are: 3.comp..sink 2 comp. sink, 1 comp. sink, dishwasher, rinse sink, garbage grinder and mop sink. !NilsalLLegenera ive water epftezl&r allowed- only-exd ngeahle hettlec itystern are eernliysiwe- 'CVWD source control will inspect the exl osed grease interceptor plumbing, please call (760)_398-2661 ext 3708 48 hours in advance to schedule an inspection.rI lilt• art; Itc.,itn, ,• u �V l 78 V frr 5 5 D - h- t .,• Ic llau -3�a7 a o j� i Z; ZG10 wIATER COACHELLA VALLEY WATER DISTRICT O�STRtG'C P.O. BOX 1058, COACHELLA, CALIFORNIA 92236 (760) 398-2651 INVOICE Date:3/23/2020 SUBJECT: PM 37207, SILVERROCK, 25000 SILVERROCK WAY LA OUINTA, "MONTAGE HOTEL" (SOURCE CONTROL ONLY) ROBERT GREEN Project: 20-10873 3551 FORTUNA RANCH RD. Project Date: 2/26/2020 Amount Due: S50.00 ENCINITAS. CA 92024 GEO: 06-07-05-3 Planner: SARA LOPEZ TO INSURE PROPER CREDIT. PLEASE RETURN THIS PORTION WITH REMITTANCE AND INCLUDE THE PROJECT ON YOUR CHECK �W�� Fee Type Description Charge Amount Total Amount 1.00 SA APPiVVAIVER FEE SOURCE CNTRL $50.001 $50.00 S50.00 Paid$f2l)- r4H1)79 Development Services Departure t MAR 2 5 2020 Coachella Valley Water District 75-515 Hovely Lane Ease Palm Desert, CA 92211 SUBJECT: PM 37207, SILVERROCK, 25000 SILVERROCK WAY, LA QUINTA, "MONTAGE HOTEL" (SOURCE CONTROL ONLY) COACHELLA VALLEY WATER DISTRICT P.O. BOX 1058, COACHELLA, CALIFORNIA 92236 (760) 398-2651 Pagel CO&C:HEI 1.4 VALLT- WATER DIS7'RIC'r 75-515 Holo9ey Lane East Pslm Desert, California 92211 z 1"60>?�18 2651 AP LiCAT1U\ I i)i2 WASTEWATER SOURCE CONTROL PLAN APPROVAt. % 1 . Ir • X I , . h r •b -I I•n• Ih o ' ot•y (,fa >cAi.L-D plc: pi as (1 •'-uv to I ' - 40' SCALE) dra.vn t, Dizmrl tpcuttr a', tins A none: f::rdabl: !:hnE (cc I- L; ^I,::1 ems, ►K made rr:e lr u• the Ceache;L 1 sliry W ter D:ctnr App:o•.al of t1.a :ppileauon ;hall cram vafr: I •,. n • i. ,: , , .n• i n date of pa}ir:nt NOTE: ALIi USERS DiSQHARGINC FAT, OiI.,'AMOR GREASE, LUC,ITEU IN AAILILi I- 501TE DUILOING µ'ILL R,4VIARE A SEPARATE LATEBAI. QFFTUEVAIN SlrM$RLI;M.FOR GREASE LNTERCEPTQR60Nh1EMO. CI'\VD Source Cont-al nill inrpret the rsPosrd grease plumbing Red ihe,ntiaUrd ittricepteir Please tal!,1011911-:6n: Xt536 4P houvi in ad,,,., :e irlicdule tot citun'u - rvm, Coivractor i on[c rrnnr AJErc„ "P Te ara, n,r Andrew 225 Broadxay Su le I03 5an'D,eao (.A 92101 'rtin:: (619) 223 3131 ad:a, Su:e SP Tee, ru,.c FlnDen Goan 3551, Forfi rti, Ranch, Roao Encrni:as CA 92024 f7601 634 6p43 lib F,ic Addirtsr r lt\ --—. — 25-000 SdvorRocl. III La Cuirta 92253 rhnmas r'rr, Damn$ "Mors'. M - - — -- - l r, C Ls' jil`?"G l� l Silver nociI. I anpinp l.f C %CITE: NO PLANS WILL BE APPR(1N-11) UNTIL THIS APPLICATION IS COMPLETE AND PI..4'I CHECK FFFS .ARF PAID Tylip or Construction: it Nett b Rcmodc Yours of Oncralmn ham. • 10prn __ Cooitng Tcurgsl n For Food Service: rur Vehicle Se►tice: — 11 Wand bays ❑ Trench Drain. i _ !t � �11'atec 5ohenof ❑ GarFagc i-JrtrdVi3jI ❑ C•,gc•tcdsl 13 RAI over ❑ Service b.vgsl _ Aluttismice (rc.tanb'.cI100 t- Singk Sen:.e (d:sposat>1c;0 0 7unnrt.. rtfsJ O Pausher Searing Copact+. Inrcrnal 86 C�icrnaf D Spill Containmen• tSahrrri :3 Aqueous ❑ i Seving with Misicis or Htalen D fltdraulic l.i(Ilsj DWork Sinklsi _ &ar Scaiin 74 Bar SCh-1W.It• VOMI Sm tte 1 t 1, NL't2;R13PJ C5f".'I'A,T 11'l hl:Cl AP A710K I cenlr,. iha: I hate read the entire application ;nil r.tat: thai al'. oiLirmat,oa I: correct 1 tin,;cistanr, that the fee amount Ir, hated on rn. declar.Ni,.m of inrur:naiion on Jim fern: aiid ttint imorreci mrunrian-,n is ground; for r-m.lion of the suhIrilucn Blare. t also uudc'mand that flans mnt III, dmcwol it not l-kcd ur %•oleo m.-tt ;bill days of approval nr relict.:,girl :ha• n'v uispccuui, uriny rctabli,hnient w;lf he condd;le-d %,wil all "qu:sicd infurnmior has beer, iccel and plans III%r bcco apprc ed S,Ella: utc _�-�---- Pate FOR DJSTR1(MUSVU1fLY• \n orS,•�iem7 Type fre(rcatmeniE•qutl-amit 2 Cocasc Ir,i rccptnt ❑(,rcatr Inincepwrllmtcd m New Q LKisung 1 ❑ Smid ( W ❑ C'onnc: i to Scwc- ❑ Addi:iun ❑ 1_ir,l Trap t-3'uinc of Connccur,n Sample Stauw: ❑ R,plarrnent ❑ :'lamer C Digc;,c;si Stu 100 s awith sample box - RL'�'fAl2k5: I o ga grease interce tors must have its own sample box. 'Discharges containing lats, oils, and grease must be touted to grease interceptors, examples are: 3 comp. sink, 2 comp. sink, 1 comp. sink, dishwasher, rinse sink, garbage grinder and mop sink. "iszsalLiggsiitlive water softener allowed in CVWD jurisdiction, onl, exchangeable bottle systems are permissible. •CVWD source control will inspect exposed grease interceptor plumbing, please call (760) 398 2661 ext 3708 48 hr in advance to schedule an inspection. - - --- hr, app: taboo I �( 2 lij C'und: iunall. ^pr.,.;.'' C 'See Reniaill 1(;)7 r'at' � 23� 2alp County of Riverside DEPARTMENTOF ENVIRONMENTAL HEALTH P.O. BOX 7909 • RIVERSIDE, CA92513-7909 KEITH JONES, DIRECTOR Protecting People and the E-van—, FOOD ESTABLISHMENT PLAN APPROVAL NOTICE Plan Check # 47179 Date 5/5/2020 Project Name Silver Rock Lodging (H1 and Hs) Plans Submitted by Veit Kugel Address 52-000 Silver Rock Road Phone 619-557-2529 Owner Robert Green Address 3551 Fortuna Ranch Road, Encinitas CA Phone 760-634-6543 The plans are now approved subject to the conditions listed below and the attached compliance sheet. 1. Note: As per email received on 5/5/2020 from Veit Kugel the flooring note VCT means commercial continuous sheet vinyl. 2. Provide grease interceptor approval install letter from the sewer agency prior to final inspection. 3. Provide air balance report for all exhaust and make up air prior to final inspection. 4. The bar cover must be present and installed at time of final inspection. CONSTRUCTION INSPECTIONS: Contact the Plan Checkerfor a Preliminary Inspection when construction is approximately 80% complete, with plumbing, rough ventilation, and rough equipment installed. Request for inspection should be made at least five (5) working days in advance. "ALL ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL REPAIRS AND INSTALLATIONS SHALL BE DONE UNDER PERMIT FROM THE APPROPRIATE BUILDING & SAFETY DEPARTMENT (CITY OR COUNTY) -- A FINAL INSPECTION MUST be made upon completion of ALL work including finished details. APPROVAL to operate shall not be granted, or remodeled areas approved to operate, until the facility has passed the FINAL INSPECTION, and "APPLICATION TO OPERATE" has been completed and PERMIT FEES have been paid. Request for inspection should be made at least five (5) working days in advance. PLANS CHECKED BY Tracey Ford Phone 760-863-8287 I acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate them during construction: �w�"] �_ /,� Signature_ Date 05.05.2020 Company Name Gensler Corona Hemet Indio Murrieta Palm Springs Riverside -west Riverside -Fast 2275 S. Main St ON SW S. Sanderson #200 47-950 Arabia St "A" 38740 Sky Canyon Dr. 544 S. Pasco Dorotea 4065 County Circle 3880 Leman St. Corona, Ca 92882 Hemet, Ca 92545 Indio, Ca 92201 Murrieta, Ca 92563 Palm Springs, Ca Riverside, Ca 92503 Riverside, Ca 92501 (951) 273-9140 (951) 766.2824 (760) 863-8287 (951) 461-0284 92264 (951) 358-5172 (951) 955-8%2 760.320-1048 Office Locations 0 Blythe • Corona • Hemet • Indio • Murrieta • Palm Springs • Riverside Phone (888)722-4234 www.rivcoeh.org La Quinta BCPR2019-0006 November 22, 2019 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: La Quinta PLAN CHECK #.: BCPR2019-0006 PREPARED BY: Kurt Culver, S.E. DATE: November 22, 2019 BUILDING ADDRESS: 79179 Ahmanson Lane BUILDING OCCUPANCY: BUILDING ARLA Valuation flea. VAI UI {$) PORTION ( Sq_ Ft.) Multiplier M(A 1997 UBC Building Penn* Fee qW .I 1997 UBC Plan Check Fee Type of Review Complete Review _ Structural Only ❑ Repettrve fee Othel Repeats I iouriy Hr. EsGil Fee Comments: Fees to be determined. 1. '�n l #NIA Sheet 1 of 1