BCPR2019-0003!� ylProject Details PROJECT NUMBER
City of La _Quinta
BCPR2019-0003
Description: SILVERROCK / MONTAGE LUXURY RESIDENCES SFDx4
Status: APPROVED
Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB)
Status Date: 6/8/2021
Subtype: TRACT RESIDENTIAL
Applied: 10/7/2019
Address: 79087 AHMANSON LN
Approved: 6/24/2021
City, State, Zip: LA QUINTACA92253
Closed:
Project Manager: AJ ORTEGA
Expired: 12/31/2022
Details: MONTAGE LUXURY RESIDENCES SFDx4, 2019 CALIFORNIA BUILDING CODES,
DEFERRED SUBMITTAL OF TRUSSES, PHOTOVOLTAIC SYSTEMS AND FIRE
SPRINKLERS.
ACTIONS
INSPECTIONS
CONDITIONS
)EN
TED
ADDITIONAL SITES
CHRONOLOGY 11
CONDITION
TYPE
CONTACT
DATE
ADDED
DATE
REQUIRED
DATE
SATISFIED
STATUS
REMARKS
NOTES
SEE ATTACHED PERMIT ISSUANCE CONDITION
LIST.
GEN - A
AJ Ortega
12/27/2019
6/24/2021
COMPLIES
ONLY REMAINING CONDITION IS FEE PAYMENT,
STATUS UPDATED TO COMPLIES.
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
THE ROBERT GREEN COMPANY
3551 FORTUNA RANCH
ENCINITAS
CA
92024
(805)804-2454
ED@THEROBERTGREEN
RD
COMPANY.COM
ARCHITECT
MARK GROSS & ASSOCIATES
8881 RESEARCH DRIVE
IRVINE
CA
92618
(805)804-2454
MARKG@MARKGROSSI
NC.COM
Printed: Tuesday, December 19, 2023 3:56:08 PM 1 of 10 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
CONTRACTOR
ROBERT GREEN RESIDENTIAL INC
3551 FORTUNA RANCH
ENCINITAS
CA
92024
(805)804-2454
JOSH @THEROBERTG RE
RD
ENCOMPANY.COM
DEVELOPER
SILVERROCK DEVELOPMENT
3551 FORTUNA RANCH
ENCINITAS
CA
92024
(805)804-2454
ED@THEROBERTGREEN
COMPANY, LLC
RD
COMPANY.COM
ENGINEER
GOUVIS ENGINEERING
15 STUDEBAKER
IRVINE
CA
92618
(805)804-2454
HNGUYEN@GOUVISGR
OUP.COM
OWNER
THE
ROBERT GREEN COMPANY
3551 FORTUNA RANCH
ENCINITAS
CA
92024
(805)804-2454
ED@THEROBERTGREEN
RD
COMPANY.COM
PRIMARY
PATRICK RUSSELL
3551 FORTUNA RANCH
ENCINITAS
CA
92024
(805)804-2454
PAT@THEROBERTGREE
CONTACT
RD
NCOMPANY.COM
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
BY
HOURLY CHARGE - CITY
101-0000-42600
1
$161.00
$161.00
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
BUILDING STAFF
ACCOUNT
COMPANY
HOURLY CHARGE - CITY
101-0000-42600
1
$161.00
$161.00
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
BUILDING STAFF
ACCOUNT
COMPANY
HOURLY CHARGE - CITY
101-0000-42600
2.5
$402.50
$402.50
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
BUILDING STAFF
ACCOUNT
COMPANY
HOURLY CHARGE - CITY
101-0000-42600
2
$322.00
$322.00
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
BUILDING STAFF
ACCOUNT
COMPANY
HOURLY CHARGE - CITY
101-0000-42600
2.5
$402.50
$402.50
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
BUILDING STAFF
ACCOUNT
COMPANY
HOURLY CHARGE - CITY
101-0000-42600
0
$80.50
$80.50
5/5/23
WEB15075
CTAAEC478
Trust
THE ROBERT GREEN
ECON
BUILDING STAFF
Account
COMPANY
HOURLY CHARGE -
ESGIL STRUCTURAL
101-0000-42600
21
$2,520.00
$2,520.00
12/11/19
WEB4387
CREDIT
THE ROBERT GREEN
ECON
COMPANY
ENGINEER
Total Paid for BUILDING STAFF - PER HOUR: $4,049.50
$4,049.50
Printed: Tuesday, December 19, 2023 3:56:08 PM 2 of 10 CENTRALSQUARE
Project Details PROJECT NUMBER
ow. City of La Quinta BCPR2019-0003
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
Credit Card Fee
101-0000-43505
0
$0.47
$0.47
10/7/19
WEB4156
CREDIT
THE ROBERT GREEN
ECON
COMPANY
Credit Card Fee
101-0000-43505
0
$51.16
$51.16
12/11/19
WEB4387
CREDIT
THE ROBERT GREEN
ECON
COMPANY
Total Paid for Credit Card Fee: $51.63 $51.63
FIRE STAFF - PER HOUR
101-0000-42420
2
$322.00
$322.00
12/11/19
WEB4387
CREDIT
THE ROBERT GREEN
ECON
COMPANY
FIRE STAFF - PER HOUR
101-0000-42420
1
$161.00
$161.00
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
ACCOUNT
COMPANY
Total Paid for FIRE FEES: $483.00 $483.00
RECORDS
MANAGEMENT FEE -
101-0000-42416
0
$21.00
$21.00
10/7/19
WEB4156
CREDIT
THE ROBERT GREEN
ECON
COMPANY
MAJOR
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
10/7/19
WEB4156
CREDIT
THE ROBERT GREEN
ECON
ENHANCEMENT FEE
COMPANY
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
NEW CONSTRUCTION -
101-0000-42400
0
$644.00
$644.00
6/24/21
R65759
CTAAEC478
TRUST
THE ROBERT GREEN
AHI
5+ RESIDENTIAL UNITS
ACCOUNT
COMPANY
Total Paid for ZONING CLEARANCE - PLANNING PLAN $644.00 $644.00
CHECK:
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
I COMPLETED
DATE
RESULT
REMARKS
NOTES
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES
DATE
Printed: Tuesday, December 19, 2023 3:56:08 PM 3 of 10 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
!L
City of La Quinta BCPR2019-0003
1ST BLDG (1WK)
DUANE
12/21/2021
1/3/2022
1/10/2022
APPROVED
2019 CODE UPDATE -
- SEE APPROVED TRUSS PACKAGE IN
CLAYTON
TRUSS CALCULATIONS
ATTACHMENTS.
21 HRS at $120.00 (Non -Structural and Structural)
1ST BLDG (2WK)
KURT CULVER
10/10/2019
10/24/2019
10/22/2019
REVISIONS REQUIRED
Per Invoice from EsGil
ENERGY DOCUMENTS REQUIRED TO BE
1ST BLDG (2WK)
AJ ORTEGA
4/23/2021
5/7/2021
5/19/2021
REVISIONS REQUIRED
2019 CODE UPDATE
REGISTERED AND ALSO INCORPORATED INTO THE
PLAN SET, CURRENT SUBMITTAL HAS OLD
ENERGY WITHIN THE PLANS.
INFORMATION CORRELATED AND RETURNED TO
1ST BLDG NS (3WK)
AJ ORTEGA
10/7/2019
10/28/2019
10/31/2019
REVISIONS REQUIRED
APPLICANT, SEE ATTACHED EMAIL
CORRESPONDENCE.
SEE CODE UPDATE - 1ST REVIEW ESGIL
1ST BLDG STR (2WK)
KURT CULVER
4/23/2021
5/7/2021
5/10/2021
APPROVED
2019 CODE UPDATE -
TRANSMITTAL 1
STRUCTURAL ONLY
1ST FIRE (1WK)
KOHL
4/26/2021
5/3/2021
5/4/2021
APPROVED
2019 CODE UPDATE
SEE COA LETTER ATTACHED
HETRICK
Printed: Tuesday, December 19, 2023 3:56:08 PM 4 of 10 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
1ST FIRE (2WK)
FIRE BUCKET
10/7/2019 1
10/17/2019 1
10/25/2019
COMPLETE
See comments and
Fire Flow Ltr
FIRE GENERAL CONDITIONS
Fire access shall be provided in compliance with
CFC 503.1.1.
Property/Unit Addressing shall be provided.
Minimum 4-inch tall numbers of contrasting color
to their background shall be posted at the
driveway entrance and maintained visible.
Vehicle Gates/barricades restricting fire access to
the structure shall be provided with KNOX
emergency access. (CFC 503.6)
A separate letter has been provided identifying
the required fire flow for TTM 37730.
A Residential Fire Sprinkler system shall be
installed in compliance with CRC R313. CA
Licensed Contractor (C-16) shall submit plans and
details for review and approval prior to Rough
Inspections.
Printed: Tuesday, December 19, 2023 3:56:08 PM 5 of 10 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
FIRE GENERAL CONDITIONS
Fire access shall be provided in compliance with
CFC 503.1.1.
Property/Unit Addressing shall be provided.
Minimum 4-inch tall numbers of contrasting color
to their background shall be posted at the
driveway entrance and maintained visible.
Vehicle Gates/barricades restricting fire access to
1ST FIRE (2WK) FIRE BUCKET 10/7/2019 10/17/2019 10/25/2019 COMPLETE See comments and Fire Flow Ltr the structure shall be provided with KNOX
emergency access. (CFC 503.6)
A separate letter has been provided identifying
the required fire flow for TTM 37730.
A Residential Fire Sprinkler system shall be
installed in compliance with CRC R313. CA
Licensed Contractor (C-16) shall submit plans and
details for review and approval prior to Rough
Inspections.
1ST PERMIT
AJ ORTEGA
10/7/2019
10/8/2019
10/10/2019
COMPLETE
TECHNICIAN (1DAY)
1ST PLANNING
NICOLE
10/7/2019
10/21/2019
10/8/2019
COMPLETE
Plans are consistent with approved SDP.
(2WK)
CRISTE
1ST PUBLIC WORKS
APPROVED-
NEED APPROVAL OF FINAL MAP, PGP, PAD CERTS,
(2WK)
AMY YU
10/7/2019
10/17/2019
10/16/2019
CONDITIONS
AND COMPACTION REPORT PRIOR TO BUILDING
PERMIT ISSUANCE
2ND BLDG (1WK)
KURT CULVER
12/11/2019
12/18/2019
12/16/2019
READY FOR APPROVAL
2ND BLDG (1WK)
AJ ORTEGA
6/8/2021
6/15/2021
6/24/2021
APPROVED
2019 CODE UPDATE
SUBMITTAL OF SEQUENCE SHEET (BUILDING
PERMIT APPLICATION FOR EACH INDIVIDUAL
2ND BLDG NS (2WK)
AJ ORTEGA
12/11/2019
12/26/2019
12/27/2019
APPROVED-
SITE), APPROVAL OF FINAL MAP, PGP, PAD CERTS,
CONDITIONS
AND COMPACTION REPORT PRIOR TO BUILDING
PERMIT ISSUANCE.
Printed: Tuesday, December 19, 2023 3:56:08 PM 6 of 10 CENTRALSQUARE
Project Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BCPR2019-0003 - 1ST
DOC
10/9/2019
AJ ORTEGA
1ST SUBMITTAL PLAN
SUBMITTAL PLAN
0
SET
SET.pdf
BCPR2019-0003 - CODE
CODE UPDATE - ENERGY
DOC
6/24/2021
AJ ORTEGA
DOCUMENTS
UPDATE -ENERGY
1
(APPROVED)
DOCUMENTS
(APPROVED).pdf
BCPR2019-0003 - CODE
DOC
6/24/2021
AJ ORTEGA
CODE UPDATE - PLAN
UPDATE - PLAN SET
1
SET (APPROVED)
(APPROVED).pdf
CODE UPDATE -
BCPR2019-0003 - CODE
DOC
6/24/2021
AJ ORTEGA
STRUCTURAL
UPDATE -STRUCTURAL
1
CALCULATIONS
CALCULATIONS
(APPROVED)
(APPROVED).pdf
DOC
8/11/2021
AJ ORTEGA
Mockup Sheet - Plan 1
Mockup Sheet - Plan
0
1.pdf
DOC
8/11/2021
AJ ORTEGA
Mockup Sheet - Plan 2
Mockup Sheet - Plan
0
2.pdf
DOC
8/11/2021
AJ ORTEGA
Mockup Sheet - Plan 3
Mockup Sheet - Plan
0
3.pdf
DOC
8/11/2021
AJ ORTEGA
Mockup Sheet - Plan 4
Mockup Sheet - Plan
0
4.pdf
BCPR2019-0003 - CODE
CODE UPDATE - 1ST
DOC
12/21/2021
AJ ORTEGA
SUBMITTAL TRUSS
UPDATE - 1ST
1
SUBMITTAL TRUSS
CALCULATIONS
CALCULATIONS.pdf
BCPR2019-0003 - CODE
CODE UPDATE - TRUSS
DOC
1/10/2022
DUANE CLAYTON
CALCULATIONS
UPDATE -TRUSS
1
CALCULATIONS
(APPROVED)
(APPROVED).pdf
Printed: Tuesday, December 19, 2023 3:56:08 PM 7 of 10 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BCPR2019-0003 -
DOC
10/7/2019
EtrakitContractor
GEOTECHNICAL
GEOTECHNICAL
1
INVESTIGATION
INVESTIGATION.pdf
BCPR2019-0003 -
DOC
10/7/2019
EtrakitContractor
GEOTECHNICAL
GEOTECHNICAL
1
SUPPLEMENT
SUPPLEMENT.pdf
BCPR2019-0003 - 1ST
1ST SUBMITTAL
DOC
10/7/2019
EtrakitContractor
STRUCTURAL
SUBMITTAL
0
STRUCTURAL
CALCULATIONS
CALCULATIONS.pdf
BCPR2019-0003 - 1ST
DOC
10/7/2019
EtrakitContractor
1ST SUBMITTAL ENERGY
SUBMITTAL ENERGY
0
DOCUMENTS
DOCUMENTS.pdf
BCPR2019-0003 - 1ST
DOC
10/7/2019
EtrakitContractor
1ST SUBMITTAL
SUBMITTAL
0
TRANSMITTAL LETTER
TRANSMITTAL
LETTER.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL PLAN
SUBMITTAL PLAN
0
SET
SET.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL CIVIL
SUBMITTAL CIVIL
0
RESPONSES
RESPONSES.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL GRILL
SUBMITTAL GRILL and
0
and HOOD SPEC
HOOD SPEC.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL PLAN
SUBMITTAL PLAN CHECK
0
CHECK RESPONSES
RESPONSES.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL
SUBMITTAL
0
STRUCTURAL CALCS
STRUCTURAL CALCS.pdf
Printed: Tuesday, December 19, 2023 3:56:08 PM 8 of 10 a CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BCPR2019-0003 - 2ND
2ND SUBMITTAL
DOC
12/11/2019
EtrakitContractor
STRUCTURAL
SUBMITTAL
0
STRUCTURAL
RESPONSES
RESPONSES.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL
SUBMITTAL ENERGY
0
ENERGY DOCUMENTS
DOCUMENTS.pdf
BCPR2019-0003 - 2ND
DOC
12/11/2019
EtrakitContractor
2ND SUBMITTAL
SUBMITTAL ENERGY
0
ENERGY DOCUMENTS
RESPONSES.pdf
BCPR2019-0003 - CODE
CODE UPDATE - 1ST
DOC
4/23/2021
EtrakitContractor
SUBMITTAL PLAN SET
UPDATE - 1ST
0
SUBMITTAL PLAN SET
VOL1
VOL 1.pdf
BCPR2019-0003 - CODE
CODE UPDATE - PLAN
DOC
4/23/2021
EtrakitContractor
SET VOL 2 (FOR
UPDATE - PLAN SET VOL
1
2 (FOR REFERENCE
REFERENCE ONLY)
ONLY).pdf
BCPR2019-0003 - CODE
CODE UPDATE - 1ST
UPDATE -1ST
DOC
4/23/2021
EtrakitContractor
SUBMITTAL
SUBMITTAL
0
STRUCTURAL
STRUCTURAL
CALCULATIONS
CALCULATIONS.pdf
BCPR2019-0003 - CODE
CODE UPDATE - 1ST
DOC
4/23/2021
EtrakitContractor
SUBMITTAL ENERGY
UPDATE - 1ST
0
SUBMITTAL ENERGY
DOCUMENTS
DOCUMENTS.pdf
BCPR2019-0003 - CODE
CODE UPDATE - 2ND
DOC
6/7/2021
EtrakitContractor
SUBMITTAL ENERGY
UPDATE-2ND
0
SUBMITTAL ENERGY
DOCUMENTS
DOCUMENTS.pdf
Printed: Tuesday, December 19, 2023 3:56:08 PM 9 of 10 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2019-0003
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BCPR2019-0003 - CODE
CODE UPDATE - 2ND
DOC
6/7/2021
EtrakitContractor
SUBMITTAL ENERGY
UPDATE-2ND
0
SUBMITTAL ENERGY
PLAN SHEETS
PLAN SHEETS.pdf
BCPR2019-0003 -
DOC
6/7/2021
EtrakitContractor
DEFERRED TRUSS
DEFERRED TRUSS
1
ACKNOWLEDGEMENT
ACKNOWLEDGEMENT.p
df
BCPR2019-0003 - 1ST
DOC
10/23/2019
JAKE FUSON
1ST REVIEW ESGIL
REVIEW ESGIL
0
COMMENTS
COMMENTS.pdf
DOC
10/23/2019
JAKE FUSON
1ST REVIEW - ESGIL
1ST REVIEW - ESGIL
0
INVOICE
INVOICE.pdf
CODE UPDATE - 1ST
BCPR2019-0003 - CODE
DOC
5/10/2021
JAKE FUSON
REVIEW ESGIL
UPDATE - 1ST REVIEW
0
TRANSMITTAL
ESGIL TRANSMITTAL.pdf
BCPR2019-0003-15T
DOC
10/23/2019
KURT CULVER
1ST REVIEW ESGIL
REVIEW ESGIL
0
COMMENTS
COMMENTS (DOC
FILE).doc
Fire Flow Req. -
Fire Flow Req. -
DOC
10/25/2019
KOHL HETRICK
SilverRock _ Montage _
SilverRock _ Montage _
1
Luxury Residences (TTM
Luxury Residences (TTM
37730).pdf
37730).pdf
BCPR2019-0003 -
MONTAGE RESIDENCES
DOC
5/4/2021
KOHL HETRICK
- FIRE CONDITIONS OF
MONTAGE RESIDENCES
1
- FIRE CONDITIONS OF
APPROVAL.pdf
APPROVAL.pdf
Printed: Tuesday, December 19, 2023 3:56:08 PM 10 of 10 CENTRALSQUARE
ADDRESS Montage Luxury Residences SFDx4
PROJECT DESCRIPTION
Plan 1
APPLICATION
VALID UNITL DATE
Mechanical
BCPR2019-0003
Units
New Construction
FURNACE
3
HEATER
CONDITIONED/AC (SF)
3,938
APPLIANCE (ALT/ADD)
GARAGE/UNCOND (SF)
617
COMPRESSOR
4
PATIO/COVERED (SF)
733
AIR HANDLER
1
FIRE SPRINKLER (SF)
4555
EVAP COOLER
VENT FAN
8
CODE EDITION
2019
EXHAUST HOOD
1
CONSTRUCTION TYPE
VB
MISC MECHANICAL
GOOD
YES
NUMBER OF FLOORS
1
Electrical
Units
NUMBER OF BEDROOMS
3
NUMBER OF UNITS
1
NEW ELECTRICAL (SF;
4555
OCCUPANT LOAD
N/A
and/or
OCCUPANCY
R3
RECEP/SWITCH/LIGHT
MSHCP (DU/ACRE)
2.08
plus
(DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE)
APPLIANCE - RES
APPLIANCE - NONRES
Options
POWER APPARATUS
SIGNS
SERVICE
THEATER (SF)
No Change
TEMPORARY SERVICE
FXITURE/TRAP
-3
MISC ELECTRICAL
VENT FAN
-1
LIGHT POLES
PV SYSTEM - ARRAY
JUNIOR MASTER (SF)
No Change
PV SYSTEM - MISC EQ
FIXTURE/TRAP
+3
VENT FAN
+2
Plumbing
Units
BEDROOM
+1
FIXTURE/TRAP
26
SEWER
1
SEPTIC
ROOF DRAIN
8
Grading
WATER HEATER
2
GREASEINTERCEPTOR
TRACT
1
WATER PIPING
1
CUSTOM HOME <=7KSF
BACKFLOW
1
CUSTOM HOME >7KSF
GAS OUTLETS
11
CREATED: 5/27/2021
BY: AORTEGA
Unit Counts
TOILETS
BIDET/URINAL
SHOWERS
BATHTUBS
SINKS
BAR SINK
BBQ
OVEN
RANGE
COOKTOP
DRINKING FOUNTAIN
WASHER
DRYER
WATER HEATER
ROOF DRAINS
FLOOR DRAINS
KITCHEN SINK
VEGGIE SINK
LAUNDRY SINK
FIREPLACE
Qty
CREATED: 5/27/2021 BY: AORTEGA
ADDRESS Montage Luxury Residences SFDx4
PROJECT DESCRIPTION
Plan 2
New Construction
CONDITIONED/AC (SF)
4,262
GARAGE/UNCOND (SF)
623
PATIO/COVERED (SF)
1029
FIRE SPRINKLER (SF)
4885
CODE EDITION
2019
CONSTRUCTION TYPE
VB
GOOD
YES
NUMBER OF FLOORS
1
NUMBER OF BEDROOMS
4
NUMBER OF UNITS
1
OCCUPANT LOAD
N/A
OCCUPANCY
R3
MSHCP (DU/ACRE)
2.08
(DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE)
Options
THEATER (SF)
No Change
FXITURE/TRAP
-3
VENT FAN
-1
CASITA 1 (SF)
+391
FXITURE/TRAP
+4
VENT FAN / AIR / COMP
+1
BEDROOM
+1
WATER HEATER
+1
CASITA 2 / POOL HOUSE (SF)
+501
FXITURE/TRAP
+4
VENT FAN / AIR / COMP
+1
BEDROOM
+1
WATER HEATER
+1
Grading
TRACT 1
APPLICATION BCPR2019-0003
VALID UNITL DATE
Mechanical
FURNACE
HEATER
APPLIANCE (ALT/ADD)
COMPRESSOR
AIR HANDLER
EVAP COOLER
VENT FAN
EXHAUST HOOD
MISC MECHANICAL
Electrical
Units
2
3
1
9
1
Units
NEW ELECTRICAL (SF; 4885
plus
OPTIONS (SF; (See Options)
plus
APPLIANCE - RES
APPLIANCE - NONRES
POWER APPARATUS
SIGNS
SERVICE
TEMPORARY SERVICE
MISC ELECTRICAL
LIGHT POLES
PV SYSTEM - ARRAY
PV SYSTEM - MISC EQ
Plumbing Units
FIXTURE/TRAP
SEWER
SEPTIC
ROOF DRAIN
WATER HEATER
GREASEINTERCEPTOR
WATER PIPING
BACKFLOW
GAS OUTLETS
29
1
14
2
1
1
11
CREATED:5/27/2021
BY: AORTEGA
Unit Counts
TOILETS
BIDET/URINAL
SHOWERS
BATHTUBS
SINKS
BAR SINK
BBQ
OVEN
RANGE
COOKTOP
DRINKING FOUNTAIN
WASHER
DRYER
WATER HEATER
ROOF DRAINS
FLOOR DRAINS
KITCHEN SINK
VEGGIE SINK
LAUNDRY SINK
FIREPLACE
Qty
CREATED: 5/27/2021 BY: AORTEGA
ADDRESS Montage Luxury Residences SFDx4
PROJECT DESCRIPTION
Plan 3
New Construction
CONDITIONED/AC (SF)
4,948
GARAGE/UNCOND (SF)
646
PATIO/COVERED (SF)
621
FIRE SPRINKLER (SF)
5594
CODE EDITION
2019
CONSTRUCTION TYPE
VB
GOOD
YES
NUMBER OF FLOORS
1
NUMBER OF BEDROOMS
5
NUMBER OF UNITS
1
OCCUPANT LOAD
N/A
OCCUPANCY
R3
MSHCP (DU/ACRE)
2.08
(DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE)
Options
THEATER (SF)
No Change
BEDROOM
No Change
BEDROOM 6 (SF)
No Change
FXITURE/TRAP
+3
VENT FAN
+1
BEDROOM
+1
CASITA 1 (SF)
+187
FXITU RE/TRAP
+1
BEDROOM
No Change
CASITA 2 / POOL HOUSE (SF)
+451
FXITURE/TRAP
+3
VENT FAN / AIR / COMP
+1
BEDROOM
+1
Grading
TRACT 1
APPLICATION BCPR2019-0003
VALID UNITL DATE
Mechanical
FURNACE
HEATER
APPLIANCE (ALT/ADD)
COMPRESSOR
AIR HANDLER
EVAP COOLER
VENT FAN
EXHAUST HOOD
MISC MECHANICAL
Electrical
Units
2
3
1
10
1
Units
NEW ELECTRICAL (SF; 5594
plus
OPTIONS (SF; (See Options)
plus
APPLIANCE - RES
APPLIANCE - NONRES
POWER APPARATUS
SIGNS
SERVICE
TEMPORARY SERVICE
MISC ELECTRICAL
LIGHT POLES
PV SYSTEM - ARRAY
PV SYSTEM - MISC EQ
Plumbing Units
FIXTURE/TRAP
SEWER
SEPTIC
ROOF DRAIN
WATER HEATER
GREASEINTERCEPTOR
WATER PIPING
BACKFLOW
GAS OUTLETS
34
1
12
3
1
1
11
CREATED:5/27/2021
BY: AORTEGA
Unit Counts
TOILETS
BIDET/URINAL
SHOWERS
BATHTUBS
SINKS
BAR SINK
BBQ
OVEN
RANGE
COOKTOP
DRINKING FOUNTAIN
WASHER
DRYER
WATER HEATER
ROOF DRAINS
FLOOR DRAINS
KITCHEN SINK
VEGGIE SINK
LAUNDRY SINK
FIREPLACE
Qty
CREATED: 5/27/2021 BY: AORTEGA
ADDRESS Montage Luxury Residences SFDx4
PROJECT DESCRIPTION
Plan 4
New Construction
CONDITIONED/AC (SF)
4,896
GARAGE/UNCOND (SF)
632
PATIO/COVERED (SF)
934
FIRE SPRINKLER (SF)
5528
CODE EDITION
2019
CONSTRUCTION TYPE
VB
GOOD
YES
NUMBER OF FLOORS
1
NUMBER OF BEDROOMS
4
NUMBER OF UNITS
1
OCCUPANT LOAD
N/A
OCCUPANCY
R3
MSHCP (DU/ACRE)
2.08
(DWELLING UNITS PER ACRE, EX: 43,5605F/7,000SF Lot = 6.22DU/ACRE)
Options
THEATER (SF)
No Change
BEDROOM
No Change
BEDROOM 5 (SF)
No Change
FXITURE/TRAP
+3
VENT FAN
+1
BEDROOM
+1
OFFICE / YOGA (SF)
No Change
FXITURE/TRAP
-3
VENT FAN / AIR / COMP
-1
BEDROOM
-1
Grading
TRACT 1
APPLICATION BCPR2019-0003
VALID UNITL DATE
Mechanical Units
FURNACE
HEATER
APPLIANCE (ALT/ADD)
COMPRESSOR
AIR HANDLER
EVAP COOLER
VENT FAN
EXHAUST HOOD
MISC MECHANICAL
Electrical
2
3
1
10
1
Units
NEW ELECTRICAL (SF; 5528
plus
OPTIONS (SF; (See Options)
plus
APPLIANCE - RES
APPLIANCE - NONRES
POWER APPARATUS
SIGNS
SERVICE
TEMPORARY SERVICE
MISC ELECTRICAL
LIGHT POLES
PV SYSTEM - ARRAY
PV SYSTEM - MISC EQ
Plumbing Units
FIXTURE/TRAP
SEWER
SEPTIC
ROOF DRAIN
WATER HEATER
GREASE INTERCEPTOR
WATER PIPING
BACKFLOW
GAS OUTLETS
34
1
8
2
1
1
11
CREATED:5/27/2021
BY: AORTEGA
Unit Counts
TOILETS
BIDET/URINAL
SHOWERS
BATHTUBS
SINKS
BAR SINK
BBQ
OVEN
RANGE
COOKTOP
DRINKING FOUNTAIN
WASHER
DRYER
WATER HEATER
ROOF DRAINS
FLOOR DRAINS
KITCHEN SINK
VEGGIE SINK
LAUNDRY SINK
FIREPLACE
Qty
CREATED: 5/27/2021 BY: AORTEGA
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT uCv
BILL WEISER — FIRE CHIEF
OFFICE OF THE FIRE MARSHAL — LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
May 4, 2021
The Robert Green Company
3551 Fortuna Ranch Rd
Encinitas, CA 92024
Re: Residential Building Tract Plans - Fire Plan Review — MONTAGE LUXURY RESIDENCES SFD
X4 (2019 CODE UPDATES)
BCPR2019-0003 / 79087 AHMANSON LANE, LA QUINTA, CA 92253
The building plans you submitted for the above referenced project have been reviewed by Riverside County
Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions.
Fire Department approval is based upon the 2019 CBC/CRC requirements for R-3/U occupancies in a
planned/tract community.
TRACT ACCESS & WATER REQUIREMENTS:
ACCESS
Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with
the California Fire Code, La Quinta Municipal Code and Riverside County Fire Department Standards.
1) Certain designed areas will be required to be maintained as fire lanes and will require approved signs
and/or red painted curbs.
2) Vehicle access gates shall be provided with KNOX Box, Padlock or Key -switch access. Automatic gates
shall also have Opticom IR receivers.
3) Approved street signs shall be installed and visible.
4) No Traffic Calming Devices shall be installed. *Future/proposed traffic calming devices require
approval by the Office of the Fire Marshal.
WATER
1) Fire hydrants shall be installed within 600 feet hose -lay length of the proposed residential units.
2) An observable minimum fire flow shall be present upon testing.
3) Fire hydrant caps shall be in place and marked in accordance with local requirements.
4) Blue roadway reflector shall be installed in the completed roadway to identify the location of all fire
hydrants.
5) Hydrant roadway valve boxes shall have their coverplate or lid exposed and easily accessible.
PRIOR TO PERMIT RELEASE INSPECTION
1) Individual Tract Home (Production) permits will not be released until a Tract Access/Water inspection
has been completed for the affected phase or groupingof lots. Applicant/Contractor shall be responsible
for contacting the Office of the Fire Marshal to schedule inspections. Request for inspections are to be
made at least 48 hours in advance and may be arranged by calling 760-777-7131.
DEFERRED SUBMITTALS REQUIRED
1) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed
Contractor (C-16) shall submit plans and details for review and approval prior to Rough Inspections.
a. Residential Fire Sprinkler permits may be applied for as Master Plan Types. A single Fire
Sprinkler Master Plan permit for each different plan type may be individually applied for.
Coordinate with the La Quinta Permit Technicians for appropriate application and fee
process.
GENERAL CONDITIONS
1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their
background shall be posted at the driveway entrance and maintained visible.
2) All HOA and Private landscaping shall maintain a minum 3-feet radius clearance around the
circumference of fire protection equipment, that includes fire hydrants.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
1. Effective July 1, 2019, new or replacement garages shall have battery back-up
installed for any garage door openers. SB969.
2. Please provide listing information for the outdoor cooking appliance, to verify
clearance to combustibles and overhead protection. If this is an unlisted
appliance, it cannot be installed beneath a combustible overhead. CIVIC Section
921.0.
3. Revise the Green Building Standards Codes notes to specify 1.8 gpm for
showers (not 2.0 gpm).
4. At the master bedroom of Plan 1, a smoke alarm is missing.
5. At the Junior Master Bath of Plan 1, a receptacle is missing at the lavatory.
6. This also occurs at the Powder room of Plan 3.
7. The cross sections and elevations are incomplete for Plan 2 (and, to a lesser
degree, for Plan 4, too).
8. At the Plan 2 utility plans, some of the notes are duplicated and/or occur on top
of each other, thus making them illegible.
9. Bedroom 6 of Plan 3 opens into an enclosed courtyard. Please obtain a ruling
from the Building Official as to whether this will be acceptable or not.
10. Submit "registered" Title 24 energy documentation.
11. The plans and calculations refer to post -tensioned slabs, but nothing regarding
post -tensioning was provided. Please explain.
12. Please provide a narrative, along with detailing, to show how lateral loads will be
transferred at the clerestories (from the upper roof diaphragm to the lower level).
13. At details 7 and 15 on SD3, specify the spacing of the ledger bolting. Also,
provide calculations.
La Quinta BCPR2019-0003
October 22, 2019
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: La Quinta PLAN CHECK #.: BCPR2019-0003
PREPARED BY: Kurt Culver, S.E. DATE: October 22, 2019
BUILDING ADDRESS: 79087 Ahmanson Lane
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION (Sq. Ft.) Multiplier
Reg.
mod.
VAI U1 {$)
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Junsoiction Code Iq Manual Input
E1997 UBC Building Permit Fee I
1997 Ut3C Plan Check Fee
Type of Review P
Complete Review
Repethve Fee Q Olhel
Repeats r Hourly
EsGil Fee
Based on hourly rate
Comments:
❑ Structural Only
21 Hrs. c@ `
$170 00
F-
$2, 520.00
Sheet 1 of 1
DEFERRED TRUSS SUBMITTAL REQUEST
Date: 06/07/2021
Permit Application Number: BCP2O19-003
Project Street Address: Conchilla Ct.
Applicant: SilverRock Development Co. LLC
Policy Conditions and Acknowledgment:
W] Limited to Tract Model Home Unit Only
W 0"&(V
uLIK)RNL4 —
Submittal Package Shall Consist of Electronically Stamped and Signed Truss Calculations with Engineer
of Record's Acceptance and a Roof Truss Layout
aCity Anticipated Initial Review Time is Ten (10) Working Days with Rechecks of Five (5) Workings Days
Fee for Plan Review and Processing will be the Actual Hourly Cost Incurred by the City Consultant and
the Hourly Cost per the Applicable Fee Schedule for City Staff
aApproval and Payment of Fees are Required Prior to Request for Roof Nail Inspection, No Exceptions
By signing this form, the applicant agrees to, and will be solely responsible for any delays incurred by not
complying with, the timelines, conditions, and requirements as identified.
Signature: ly
�6 Note: Applicant mayyrint out and sion
by hand and then return a scanned
copy back for review and anoroval
City Staff
Approved By: