Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BPLB2019-0086
ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PUBLIC COUNTER VISIT AJ ORTEGA 6/4/2019 6/4/2019 CHRIS KING (760-408-1164) CAME TO COUNTER TO DISCUSS PLUMBING PERMIT FOR CONVERSION TO PROPANE (BPLB2019-0075), NOTES GIVEN REGARDING SITE VISIT TODAY (SEE CHRONOLOGY) AND PENDING SUBMITTAL OF ENERGY DOCUMENTS, INFORMED TO REFERENCE EMAIL REGARDING OBTAINING A PERMIT SENT 5/31/2019. SITE VISIT AJ ORTEGA 6/4/2019 6/4/2019 DURING INSPECTION OF PLUMBING PERMIT FOR PROPANE CONVERSION (BPLB2019-0075) IT WAS NOTICED THAT SEDIMENT TRAP WAS NOT INSTALLED, ONCE ENERGY COMPLIANCE FORMS ARE PROVIDED BY APPLICANT, REVIEWED AND APPROVED, AND VALID ISSUANCE OF PERMIT IS COMPLETED INSTALLATION WILL BE REINSPECTED, SEE COUNTER VISIT FOR ADDITIONAL INFORMATION. CONDITIONS Description: CONVERSION FROM NATURAL GAS TO PROPANE WATER HEATER Type: PLUMBING - WATER HEATER CHANGEOUT (WEB) Subtype: Status: EXPIRED Applied: 5/31/2019 ECON Parcel No: 777490014 Site Address: 79179 AHMANSON LN LA QUINTA,CA 92253 Approved: Subdivision: PM 33367 Block: Lot: 22 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $2,500.00 Occupancy Type: Construction Type: Expired: 11/27/2019 ECON No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Ahmanson Ranch House in conjunction with development of SilverRock Resort; replacing 2005 NG WH ARG OEM boiler Printed: Tuesday, July 19, 2022 10:02:53 AM 1 of 3 Permit Details City of La Quinta PERMIT NUMBER BPLB2019-0086 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOFIA INVESTMENTS, INC/RGC 3551 FORTUNA RANCH ROAD ENCINITAS CA 92024 (760)238-2443 john@therobertgreenc ompany.com CONTRACTOR SOFIA INVESTMENTS, INC/RGC 3551 FORTUNA RANCH ROAD ENCINITAS CA 92024 (760)238-2443 john@therobertgreenc ompany.com OWNER CITY OF LA QUINTA P O BOX 1504 LA QUINTA CA 92253 (760)238-2443 john@therobertgreenc ompany.com FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 5/31/19 WEB3736 CREDIT SOFIA INVESTMENTS, INC/RGC ECON Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 Credit Card Fee 101-0000-43505 0 $2.32 $2.32 5/31/19 WEB3736 CREDIT SOFIA INVESTMENTS, INC/RGC ECON Total Paid for Credit Card Fee: $2.32 $2.32 PERMIT ISSUANCE 101-0000-42404 0 $101.40 $101.40 5/31/19 WEB3736 CREDIT SOFIA INVESTMENTS, INC/RGC ECON Total Paid for PERMIT ISSUANCE: $101.40 $101.40 WATER HEATER/VENT 101-0000-42401 0 $13.34 $13.34 5/31/19 WEB3736 CREDIT SOFIA INVESTMENTS, INC/RGC ECON WATER HEATER/VENT PC 101-0000-42600 0 $8.00 $8.00 5/31/19 WEB3736 CREDIT SOFIA INVESTMENTS, INC/RGC ECON Total Paid for PLUMBING FEES: $21.34 $21.34 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 5/31/19 WEB3736 CREDIT SOFIA INVESTMENTS, INC/RGC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$131.06 $131.06 Printed: Tuesday, July 19, 2022 10:02:53 AM 2 of 3 Permit Details City of La Quinta PERMIT NUMBER BPLB2019-0086 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/31/2019 EtrakitContractor AHRI Certificate for Bradford White Model RG275h6 Propane Boilerx AHRICertificate.pdf 1 DOC 5/31/2019 EtrakitContractor California Energy Code Requirements for LPG Water Boiler Pages from CEC-400- 2017-002-2.pdf 1 DOC 5/31/2019 EtrakitContractor BW LPG WH NAECA Compliant Specsheet residential_gas_natural _atmospheric_vent_hig h_input_naeca_complia nt_specsheet_1108.pdf 1 DOC 5/31/2019 EtrakitContractor Comparison of Subject to CEC Requirements Bradford White RG275h6x Energy Efficiency to CEC.pdf 1 PHOTO 5/31/2019 EtrakitContractor NAECE Compliance_BW Model RG275h6x WH naece compliant WH Bradford White.JPG 1 BOND INFORMATION INSPECTIONS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH – ETRAKIT (1 DAY) ARMANDO MAGALLON 5/31/2019 6/3/2019 6/4/2019 REVISIONS REQUIRED SCOPE OF WORK IS UNCLEAR, IT SEEMS LIKE APPLICANT IS ADDING A PROPANE TANK SO I REQUESTED A SITE PLAN SO WE COULD SEE WHAT APPLICANT WILL BE DOING AND SO I CAN SET APPROPRIATE REVIEWS. PARENT PROJECTS Printed: Tuesday, July 19, 2022 10:02:53 AM 3 of 3 Permit Details City of La Quinta PERMIT NUMBER BPLB2019-0086 1605.3 205 (A) The efficiency of boilers, central furnaces, duct furnaces, and unit heaters shall be no less than, and the standby loss shall be not greater than, the applicable values shown in Tables E-7, E-8, and E-9 Table E-7 Standards for Boilers Standards Appliance Output (Btu/hr) Minimum AFUE % Minimum Combustion Efficiency % * Maximum Standby Loss (watts) Gas steam boilers with 3- phase electrical supply < 300,000 75 — — All other boilers with 3- phase electrical supply < 300,000 80 — — Natural gas, non- packaged boilers ≥ 300,000 — 80 147 LPG Non-packaged boilers ≥ 300,000 — 80 352 Oil, non-packaged boilers ≥ 300,000 — 83 — *At both maximum and minimum rated capacity, as provided and allowed by the controls. Table E-8 Standards for Furnaces Appliance Application Minimum Efficiency % Central furnaces with 3-phase electrical supply < 225,000 Btu/hour Mobile Home 75 AFUE All others 78 AFUE or 80 Thermal Efficiency (at manufacturer’s option) Table E-9 Standards for Duct Furnaces Appliance Fuel Standards Minimum Thermal Efficiency %¹ Maximum Energy Consumption during standby (watts) At maximum rated capacity At minimum rated capacity Duct furnaces Natural gas 80 75 10 Duct furnaces LPG² 80 75 147 ¹ As provided and allowed by the controls. ² Designed expressly for use with LPG. (B) Natural gas-fired duct furnaces manufactured on or after January 1, 2006, shall have either power venting or an automatic flue damper. (C) See Section 1605.1(e) for design standards for unit heaters effective for models manufactured on or after August 8, 2008. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. Residential Atmospheric Vent High Input Gas Water Heater 6 or 10-Year Limited Tank Warranties / 6-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. Photo is of RG2100H6N 1108-B-1218 FEATURING: The Atmospheric Vent High Input Models Feature: Bradford White ICON System®*—Intelligent gas control with proven millivolt powered technology and built-in piezo igniter. A standard, off-the-shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity. -- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and tighter temperature differential. -- Advanced Temperature Control System—Microprocessor controls burner operation for consistent and accurate water temperature levels up to 160°F (71°C). -- Intelligent Diagnostics—Exclusive multicolor LED light indicates operation status/service required. Factory-Installed Hydrojet® Total Performance System—Sediment reducing device that also increases first hour rating of hot water while minimizing temperature build-up in tank. Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas® ) is fused to the steel surface by firing at a temperature of over 1600°F (871°C). Side Connections—3/4" (19mm) NPT tappings that allow easy connections for space heating applications (potable water only). Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. Pedestal Base (except RG2100H6N). Water Connections—Factory-installed true dielectric fittings extend water heater life and simplify water line connections. Hand Hole Cleanout—Allows inspection of tank interior and facilitates the removal of sediment deposits (RG2100H6N models only). Protective Magnesium Anode Rod—Provides added protection against corrosion for long-term, trouble-free service. 4" (107mm) “Snap Lock” Draft Diverter. T&P Relief Valve—Installed. Low Restrictive Brass Drain Valve—Durable tamper proof design. Thermostatic Mixing Valve (ASSE Approved)—Included with RG255H6N only. NOx Emissions—Less than 40 ng/J. *May vary by region A D&L E G F S B J MM C R H K R ©2018, Bradford White Corporation. All rights reserved. For field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 n Fax 215-641-1612 Technical Support 800-334-3393 n Email techserv@bradfordwhite.com Warranty 800-531-2111 n Email warranty@bradfordwhite.com International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com Ambler, PA NATURAL GAS AND LIQUID PROPANE GAS High Input Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed Recovery efficiency ranging up to 80% ModelNumber Approx.ShippingWeight lbs. AFloor toFlueConn.in. HDepth in. BJacketDia. in. RG250H6N RG255H6N RG275H6N RG2100H6N 60 1/8 58 1/2 62 5/8 711/2 25 1/2 27 1/4 29 1/4 31 3/4 22 24 26 28 1/4 4 4 4 4 57 3/8 56 1/2 60 1/16 66 1/2 GFloor toWaterConn.in. ModelNumber Approx.ShippingWeight kg. AFloor toFlueConn.mm. HDepth mm. BJacketDia. mm. RG250H6N RG255H6N RG275H6N RG2100H6N 1527 1486 1591 1816 648 657 743 806 559 607 660 718 102 102 102 102 CVentSize in. CVentSize mm. EFloor toGasConn.in. 13 13 1/8 15 15 3/16 EFloor toGasConn.mm. 330 333 381 389 FFloor toTop ofHeaterin. 56 5/8 54 3/4 59 5/8 65 5/16 FFloor toTop ofHeatermm. 1438 1391 1514 1659 JC/Lof WaterConn.in. 11 8 11 16 JC/Lof WaterConn.mm. 279 203 279 406 DFloor toT&PConn.in. 49 15/16 48 1/8 51 7/8 59 5/16 DFloor toT&PConn.mm. 1268 1222 1318 1507 1457 1435 1526 1689 GFloor toWaterConn.mm. 49 15/16 48 1/8 51 7/8 50 5/8 189 210 240 413 LFloor toSpace HeatingOutletin. 1268 1222 1318 1286 86 95 109 187 LFloor toSpace HeatingOutletmm. 3/4 3/4 1 11/4 MWaterConn.NPTin. 19 19 25 32 MWaterConn.NPTmm. 1/2 1/2 1/2 1/2 SGasConn.Sizein. 13 13 13 13 SGasConn.Sizemm. 3/4 3/4 3/4 3/4 RSpaceHeatingConn. Sizein. 19 19 19 19 RSpaceHeatingConn. Sizemm. 13 7/16 13 1/2 16 5/8 17 5/8 KFloor toSpace HeatingInletin. 341 343 422 448 KFloor toSpace HeatingInletmm. ModelNumber NominalGal.Capacity Recovery at90°F Rise* RG250H6N RG255H6N RG275H6N RG2100H6N 48 55 75 100 40 46 63 83 BTU/Hr.InputU.S.Gal.Imp.Gal. 65,000 78,000 76,000 80,000 LPBTU/Hr.Input 65,000 78,000 76,000 80,000 U.S.GPH 70 84 82 85 Imp.GPH 35 70 68 71 LPU.S.GPH 70 84 82 85 LPImp.GPH 35 70 68 71 ModelNumber NominalLiterCapacity Recovery at50°C Rise* RG250H6N RG255H6N RG275H6N RG2100H6N Liters 182 208 284 379 kWInput 19.0 22.9 22.3 23.4 LPkWInput 17.9 22.3 22.3 23.4 FirstHourRating(Gal.) 106 117 135 157 DOERatedStorageVolume(Gal.) 46 55 72 95 DOERatedStorageVolume(Liters) 174 208 273 360 UniformEnergyFactor 0.63 0.61 0.59 0.57 FirstHourRating(Liters) 401 443 477 519 UniformEnergyFactor 0.63 0.61 0.59 0.57 LPLiters/Hour 265 318 310 322 Liters/Hour 265 318 310 322 Residential Atmospheric Vent High Input Gas Water Heater General: Meets NAECA or EPACT Requirements, as applicable. All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All gas connections are 1/2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), ANSI Z21.10.3 and peak performance rated (except RG250H6N = ANSI Z21.10.1). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10” (Not available on RG255H6N). * Based on manufacturer’s rated recovery efficiency. RG2100H6N model features hand hole cleanout. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. Printed in U.S.A. RG250H6N / RG255H6N / RG275H6N H B C R A G F E D&L K MM J R S RG2100H6N 1108-B-1218 SILVERROCK ‐ AHMANSON RANCH HOUSE KITCHEN LPG CONVERSION Bradford White LPG Water Heater 5/31/2019 Watt BTU Standby Loss (BTU) Standby Loss (W) CEC max Standby Loss (W) Net Loss BW to CEC 1 3.412142 1047 307 352 (45) Conversion Factor BW LPG WH RG275H6X