BRES2024-0125 - HERS ReportCERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 1 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
GENERAL INFORMATION
01 Project Name Plan 3 - Pomona S850 w 2 BR Ste
02 Run Title Title 24 Analysis
03 Project Location Bella at Piazza Serena
04 City La Quinta 05 Standards Version 2022
06 Zip code 07 Software Version EnergyPro 9.2
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft2)3066 19 Glazing Percentage (%)15.40%
20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
22 Fuel Type Natural gas 23 No Dwelling Unit:No
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 2 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 32.5 40.9 21.4
Proposed Design
North Facing 30.6 34.9 19.3 1.9 6 2.1
East Facing 31 35.9 19.9 1.5 5 1.5
South Facing 30 35.1 19.3 2.5 5.8 2.1
West Facing 30.5 36.4 20.3 2 4.5 1.1
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 6.15 kWdc
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 3 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.4 1.91 0.25 1.17 0.15 0.74
Space Cooling 3.17 62.3 2.83 53.04 0.34 9.26
IAQ Ventilation 0.56 5.83 0.57 5.9 -0.01 -0.07
Water Heating 0.58 6.08 0.41 4.77 0.17 1.31
Self
Utilization/Flexibility
Credit
0 0
North Facing
Efficiency Compliance
Total
4.71 76.12 4.06 64.88 0.65 11.24
Space Heating 0.4 1.91 0.28 1.34 0.12 0.57
Space Cooling 3.17 62.3 2.9 54.87 0.27 7.43
IAQ Ventilation 0.56 5.83 0.57 5.9 -0.01 -0.07
Water Heating 0.58 6.08 0.4 4.64 0.18 1.44
Self
Utilization/Flexibility
Credit
0 0
East Facing Efficiency
Compliance Total 4.71 76.12 4.15 66.75 0.56 9.37
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 4 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.4 1.91 0.07 0.37 0.33 1.54
Space Cooling 3.17 62.3 2.88 54.41 0.29 7.89
IAQ Ventilation 0.56 5.83 0.57 5.9 -0.01 -0.07
Water Heating 0.58 6.08 0.39 4.6 0.19 1.48
Self
Utilization/Flexibility
Credit
0 0
South Facing
Efficiency Compliance
Total
4.71 76.12 3.91 65.28 0.8 10.84
Space Heating 0.4 1.91 0.08 0.43 0.32 1.48
Space Cooling 3.17 62.3 3 56.72 0.17 5.58
IAQ Ventilation 0.56 5.83 0.57 5.9 -0.01 -0.07
Water Heating 0.58 6.08 0.4 4.73 0.18 1.35
Self
Utilization/Flexibility
Credit
0 0
West Facing Efficiency
Compliance Total 4.71 76.12 4.05 67.78 0.66 8.34
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 5 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage
North Facing
Gross EUI1 14.36 12.94 1.42 9.89
Net EUI2 2.67 2.22 0.45 16.85
East Facing
Gross EUI1 14.36 13.37 0.99 6.89
Net EUI2 2.67 2.65 0.02 0.75
South Facing
Gross EUI1 14.36 13.22 1.14 7.94
Net EUI2 2.67 2.5 0.17 6.37
West Facing
Gross EUI1 14.36 13.35 1.01 7.03
Net EUI2 2.67 2.63 0.04 1.5
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 6 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
6.05 NA Premium (~18-20%)Fixed Microinverters true 105-300 n/a n/a <=7:12 97.5 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Indoor air quality, balanced fan
•IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE
•IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual
•IAQ Ventilation System: fault indicator display
•Non-standard roof reflectance
•Ceiling has high level of insulation
•Insulation below roof deck
•Window overhangs and/or fins
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified SEER/SEER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 7 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3 - Pomona S850 w 2 BR
Ste 3066 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
Zone 1 Conditioned HVAC1 3066 9.1 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Frontr 2X4 Zone 1 Ext. R-15 Wall + R-4.2 0 Front 233.6 33 90
Front 2X4 Siding Zone 1 Ext. R-15 Wall 0 Front 116.8 52 90
Left 2X4 Zone 1 Ext. R-15 Wall + R-4.2 0 Front 697.3 86.3024 90
Left 2X6 Zone 1 Ext. R-19 Wall + R-4.2 90 Left 163.8 8 90
Rear 2X4 Zone 1 Ext. R-15 Wall + R-4.2 180 Back 500.5 156 90
Rightr 2X4 Zone 1 Ext. R-15 Wall + R-4.2 270 Right 787.9 113 90
Rightr 2X6 Zone 1 Ext. R-19 Wall + R-4.2 270 Right 91 48 90
Garage 2X4 Zone 1>>__Garage__Garage R-15 Wall n/a n/a 169.8 17.8 n/a
Roof Zone 1 R-49 Roof Attic + R-19 BD n/a n/a 3036 n/a n/a
Furnace Zone 1 R-30 Roof Attic n/a n/a 30 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 444 n/a n/a
Front 2X4 __Garage__Ext R-0 Wall 0 Front 188.1 112 90
Left 2X4 2 __Garage__Ext R-0 Wall 90 Left 210 0 90
Rear 2X4 2 __Garage__Ext R-0 Wall 180 Back 37.9 0 90
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 8 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Right 2X4 __Garage__Ext R-0 Wall 270 Right 190.4 0 90
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 5 0.12 0.92 No No
Attic Zone 1 Attic RoofZone 1 Ventilated 5 0.12 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window Window Frontr 2X4 Front 0 1 33 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Front 2X4
Siding Front 0 1 28 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Left 2X4 Front 0 1 65 0.28 NFRC 0.22 NFRC Bug Screen
FRDR - OH Window Left 2X4 Front 0 2.8 8 0 21.3 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Left 2X6 Left 90 1 8 0.28 NFRC 0.22 NFRC Bug Screen
Window 5 Window Rear 2X4 Back 180 1 60 0.28 NFRC 0.22 NFRC Bug Screen
SGD - OH Window Rear 2X4 Back 180 12 8 1 96 0.28 NFRC 0.22 NFRC Bug Screen
Window 6 Window Rightr 2X4 Right 270 1 113 0.28 NFRC 0.22 NFRC Bug Screen
SGD - OH 2 Window Rightr 2X6 Right 270 6 8 1 48 0.28 NFRC 0.22 NFRC Bug Screen
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 9 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Main Door Front 2X4 Siding 24 0.142857
Int Garage Door Garage 2X4 17.8 0.5
Overhead Garage Door Front 2X4 112 0.7
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
FRDR - OH 19 1 2 2 0 0 0 0 0 0 0 0 0
SGD - OH 10 1 10 10 0 0 0 0 0 0 0 0 0
SGD - OH 2 19 1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth Carpeted Fraction Heated
Slab-on-Grade Zone 1 3066 241 none 0 80%No
Slab-on-Grade 2 __Garage__444 69 none 0 0%No
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 10 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Ext R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
Ext. R-15 Wall + R-4.2 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / 4.2 0.063
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: Synthetic Stucco
Ext. R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Exterior Finish: 3 Coat Stucco
Ext. R-19 Wall + R-4.2 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-19 None / 4.2 0.054
Inside Finish: Gypsum Board
Cavity / Frame: R-19 in 5-1/2 in. (R-18) /
2x6
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic RoofZone 1 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.055
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 11 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Roof Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-49 Roof Attic + R-19
BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-49 None / None 0.02
Over Ceiling Joists: R-39.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
R-30 Roof Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Over Ceiling Joists: R-20.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required Required 1860.0 4
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units Solar Heating
System
Compact
Distribution HERS Verification Water Heater
Name (#)
DHW Sys 1 Domestic Hot
Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 12 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 65 Rheem
PROPH65 T2
RH37530 (65 gal,
JA13)
TankZone __Garage____Garage__
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name Heating Equipment
Count Cooling Unit Name Cooling Equipment
Count Fan Name Distribution Name Required
Thermostat Type
HVAC1
Heating and
cooling system
other
Heating
Component 1 2 Cooling
Component 1 2 HVAC Fan 1 Air Distribution
System 1 Setback
HVAC - HEATING UNIT TYPES
01 02 03 04 05
Name System Type Number of Units Heating Efficiency Heating Unit Brand
Heating Component 1 Central gas furnace 2 AFUE - 96 n/a
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 13 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled Mulit-speed
Compressor HERS Verification
Cooling
Component 1 Central split AC 2 EER2/SEER2 12.5 15.2 Not Zonal Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 350 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 14 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness -
SRE/ASRE
Includes Fault
Indicator Display?HERS Verification Status
SFam IAQVentRpt
1-1 110 0.709091 Balanced Yes 69 / 75 Yes Yes
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 - Pomona S850 w 2 BR Ste Calculation Date/Time:2024-04-24T11:08:53-07:00 (Page 15 of 15)
Calculation Description:Title 24 Analysis Input File Name:Plan 3 - Pomona S850 w 2BR Suite.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-04-24 11:10:31
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Andre Pujic
Energy Inspectors Corporation 07/27/2024
2570 South Miller Lane
Las Vegas, NV 89117 702-365-8080
Andre Pujic
Energy Inspectors Corporation 07/27/2024
2570 South Miller Lane
Las Vegas, NV 89117 702-365-8080
424-P010143661A-000-000-0000000-0000 07/27/2024 09:58 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-E01003A-0000 Registration Date/Time: 2025-01-06 15:40:27 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:41:12
FENESTRATION INSTALLATION CF2R-ENV-01-E
(Page 1 of 4)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they
are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. The signer agrees that all applicable Mandatory
Measures were met. Temporary labels are not to be removed before verification by the building inspector.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
FENESTRATION INSTALLATION CF2R-ENV-01-E
(Page 2 of 4)
Registration Number: 424-P010143661A-000-002-E01003A-0000 Registration Date/Time: 2025-01-06 15:40:27 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:41:12
A. Fenestration/ Glazing
Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors( >= 25% glazing area).Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 square feet
(ft2) glass in door, it is assumed to meet the minimum required U-factor (0.30) and SHGC (0.23).
If meeting Exception 1 to 150.1(c)3A, Installing <= 3 square feet (ft2) tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30).
Doors with greater than or equal to 25 percent glazing area are considered glazed doors and are treated as fenestration products.
01 02 03 04 05 06 07 08 09 10 11 12
Tag ID Manufacturer/
Brand
Fenestration
Area (ft2)Orientation Chromogenic U-factor Source SHGC Source Fenestration
Type
Exterior
Shading
Devices
Comments/Sp
ecial Features
Window ABC WINDOW
SYSTEMS 33.0000 0 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
Window 2 ABC WINDOW
SYSTEMS 28.0000 0 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
Window 3 ABC WINDOW
SYSTEMS 65.0000 0 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
FRDR - OH ABC WINDOW
SYSTEMS 21.3000 0 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
Window 4 ABC WINDOW
SYSTEMS 8.0000 90 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
Window 5 ABC WINDOW
SYSTEMS 60.0000 180 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
SGD - OH ABC WINDOW
SYSTEMS 96.0000 180 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
Window 6 ABC WINDOW
SYSTEMS 113.0000 270 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
SGD - OH 2 ABC WINDOW
SYSTEMS 48.0000 270 No 0.28 NFRC 0.22 NFRC Window Standard bug
screens
B. Fenestration Installation
01 The U-factor of the installed windows for new construction and existing buildings must be equal to or less than those listed on the CF1R.
02 The SHGC of the installed windows for new construction and existing buildings must be equal to or less than those listed on the CF1R in climate zones 2, 4 and 8-15. For climate zones 1,
3, 5 and 16 there is no SHGC requirement.
03 Temporary labels are not to be removed until verified by the building inspector.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
FENESTRATION INSTALLATION CF2R-ENV-01-E
(Page 3 of 4)
Registration Number: 424-P010143661A-000-002-E01003A-0000 Registration Date/Time: 2025-01-06 15:40:27 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:41:12
B. Fenestration Installation
04 The fenestration product manufacturer's installation specifications shall be followed when installing these products. The space between the fenestration product and rough opening
shall be completely filled with insulation. If batt insulation is used, it is cut to size and placed properly around the fenestration product.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
FENESTRATION INSTALLATION CF2R-ENV-01-E
(Page 4 of 4)
Registration Number: 424-P010143661A-000-002-E01003A-0000 Registration Date/Time: 2025-01-06 15:40:27 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:41:12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Steve Uthe
Documentation Author Signature:
Company:
Nevada Window Supply Inc dba ABC Window Systems
Signature Date:
2025-01-06
Address:
1455 Columbia Avenue
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Riverside CA 92507
Phone:
(909) 946-3697
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this
statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all
applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the
enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made
available to the enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
Steve Uthe
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Nevada Window Supply Inc dba ABC Window Systems
Position With Company (Title):
Coordinator
Address:
1455 Columbia Avenue
CSLB License:
867861
City/State/Zip:
Riverside CA 92507
Phone:
(909) 946-3697
Date Signed:
2025-01-06
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 1 of 8)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Roof/Ceiling Insulation
01 02 03 04 05 06 07 08 09 10
I.D.Manufacturer and
Brand
Assembly/Framin
g Material
Assembly
Thickness (inches)
Framing Size and
Spacing Insulation Type Ceiling Insulation
R-value
Insulation Depth
(inches)
Continuous
Insulation Above
the Roof Deck
R-value
Insulation Below
the Roof Deck
R-value
R-49 Roof Attic +
R-19 BD Knauf Wood Framed
Ceiling 19.35 2x4 16InchOC Fiberglass 49 13.75 n/a n/a
R-30 Roof Attic Knauf Wood Framed
Ceiling 12.04 2x4 24InchOC Fiberglass 30 10 n/a n/a
R-0 Roof Attic Knauf Wood Framed
Ceiling 4 2x4 24InchOC Fiberglass 0 n/a n/a n/a
Attic Garage Roof
Cons Knauf Wood Framed
Ceiling 5.75 2x4 24InchOC Fiberglass 0 n/a 0 n/a
Attic RoofZone 1 Knauf Wood Framed
Ceiling 7.37 2x4 24InchOC Fiberglass 19 6.25 0 n/a
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 2 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
B. Wall Insulation
01 02 03 04 05 06 07 08 09 10
I.D.Manufacturer and
Brand
Assembly/Framin
g Material
Assembly
Thickness (inches)
Framing Size and
Spacing Insulation Type Core/Cavity
Insulation R-value
Insulation Depth
(inches)
Continuous
Exterior Insulation
R-value
Continuous
Interior Insulation
R-value
Ext. R-15 Wall +
R-4.2 Knauf Wood Framed
Walls 5.38 2x4 16InchOC Fiberglass 15 3.5 4.2 n/a
Ext. R-15 Wall Knauf Wood Framed
Walls 4.88 2x4 16InchOC Fiberglass 15 3.5 n/a n/a
Ext. R-19 Wall +
R-4.2 Knauf Wood Framed
Walls 7.38 2x6 16InchOC Fiberglass 19 6.25 4.2 n/a
Garage R-15 Wall Knauf Wood Framed
Walls 4.5 2x4 16InchOC Fiberglass 15 3.5 n/a n/a
Ext R-0 Wall Knauf Wood Framed
Walls 4.88 2x4 16InchOC Fiberglass 0 n/a n/a n/a
C. Mass Insulation
This section does not apply to this project.
D. Raised Floor Insulation
This section does not apply to this project.
E. Slab Floor/Perimeter Insulation (See Section F. For Insulation Requirements For Heated Slabs)
This section does not apply to this project.
F. Heated Slabs Insulation
01 All heated slabs shall be insulated as required by Section 110.8(g). Footings must meet required insulation levels.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 3 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
F. Heated Slabs Insulation
02 Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-15 require R-5, and climate zone 16 requires R-10.
03
Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical
insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires
R-10 vertical and R-7 horizontal.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
G. Minimum Mandatory Measures
01 Insulation - 110.8(a): All installed Insulation is certified and listed with Department of Consumer Affairs, Bureau of Household Goods and Services.
02 Insulation - 110.8(b): Urea formaldehyde foam insulation is protected by 4 mil polyethylene vapor retarder.
03 Insulation - 110.8(c): Flame spread and smoke density requirements of the California Building Code (CBC) are met.
04 Raised Floor - 150.0(d): All raised wood-frame floor have a minimum R-19 insulation or equivalent U-factor
05 Slab Floor/Perimeter - 150.0(l): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0
perm/inch and is protected from physical damage and UV light deterioration.
06 Above Grade Exterior Wall - 150.0(c)1 and 150.1(c)6: All 2x4 wood-frame walls have a minimum R-13 insulation or equivalent U-factor not exceeding U-0.102.
07 Above Grade Exterior Wall - 150.0(c)2 and 150.1(c)6: All 2x6 wood-frame walls have a minimum R-20 insulation or equivalent U-factor not exceeding U-0.071.
08 Roof Deck - 150.0(a)1: All newly constructed attic systems have a maximum area-weighted average U-factor not exceeding U-0.184.
09 Ceiling/Rafter Roof - 150.0(a)2: All wood-frame ceiling have a minimum R-22 insulation or equivalent U-factor.
10 Vapor Retarder - 150(g)1: In Climate Zones 1 through 16, the earth floor of unvented crawl space shall be covered with a Class I or Class II vapor retarder. This requirement shall also
apply to controlled ventilation crawl space for buildings complying with the Exception to Section 150.0(d).
11 Vapor Retarder - 150(g)2: In Climate Zones 14 and 16, a Class I or Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics
and unvented attics with air-permeable insulation.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 4 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
H. Installed Insulation
01 Installed insulation R-values are the same or greater than listed on the CF1R.
02 No gaps or voids between the insulation and framing.
03 No gaps between the sides or ends of batt insulation.
04 Loose-fill insulation must be installed to the minimum installed weight per square foot (density) of the manufacturer's cut sheet for the proposed R-value.
05 Batt insulation is not compressed (no stuffing of the insulation into the cavity) and is installed to its full thickness.
06 Insulation is cut around obstructions such as electrical boxes.
07 Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors.
08 Band joists are insulated to the same R-value as the wall.
09 In all narrow cavities the insulation shall be cut to fit or filled with expanding foam.
10 Insulation was installed per manufacturer instructions.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
I. Wall Insulation
01 When allowed by manufacturer, low expanding foam shall be used to fill gaps and voids around windows and doors. If not, the cavity must be air tight and filled completely with
insulation. Batt insulation must be cut to width. No stuffing allowed.
02 Install wall insulation before installing tubs, showers and fireplaces.
03 Electric panels on walls separating conditioned and unconditioned space are sealed and insulated behind the panel with rigid insulation or expanding foam.
04 All walls of interior closets vented to the outside for HVAC or water heating equipment have the same R-value and air barrier as the exterior walls and ceiling. Doors are insulated and
weather stripped.
05 Ducting not allowed in exterior walls unless insulated to R6 or greater and the insulation and ducting are not crushed.
06 Corner channels, wall intersections, and double sided shear walls insulated to the required R-value before enclosing the wall.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 5 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
I. Wall Insulation
07 Insulation that does not fill the cavity placed against exterior air barrier.
08 Band joists are insulated to the same R-value as the walls.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
J. Ceiling/ Roof Insulation
01 Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams/baffles.
02 Insulation is in direct contact with ceiling, so there are no gaps between the ceiling and the insulation.
03 For chimneys and flues, the insulation is in contact with the sheet metal collar.
04 Can lights are covered with insulation to the same depth as required by the CF1R for ceiling insulation. If not, an area weighted calculation is required to be turned in with this
compliance document (CF1R-ENV-02-E).
05 Walkways and mechanical platforms insulated to the same R-value as required for the ceiling. If not, an area weighted calculation is required to be turned in with this compliance
document (CF1R-ENV-02-E).
06 Insulate soffits by adding an air barrier and cover with insulation, or insulate the entire soffit including floor and walls.
07 Knee walls and skylight shafts are insulated to the wall R-value and in full contact with the interior air barrier. If framing on these surfaces is laid flat batt insulation is cut to fit around
the framing. Batt insulation is not allowed to be draped over the framing.
08 Attic access doors insulated to the same R-value as ceiling. The insulation is permanently attached using adhesive or mechanical fasteners.
09 Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation.
10 Batt insulation cut to fit around cross bracings and truss webs in attic.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
K. Raised Floor Insulation
01 Insulation in full contact with subfloor.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 6 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
K. Raised Floor Insulation
02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation.
03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor.
04 If the basement is conditioned the walls adjacent to the crawlspace must meet minimum wall R-value requirements. This includes framed stem walls, and vertical concrete retaining
walls.
05 If access to the crawl space is from the conditioned area, the raised floor must have an airtight insulated access hatch.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
L. Floor Above Garage Insulation
01 Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage/house wall.
02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation.
03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor.
04 If air barrier is at the perimeter of the garage, below conditioned subfloor, the insulation is placed on the garage ceiling. The perimeter of subfloor is also insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
M. Cantilevered Floor Insulation
01 Insulation in full contact with cantilevered subfloor. Insulation hangers spaced at 18 inches or less, insulation hangers do not compress insulation.
02 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor.
03 Sealed blocking is installed between joists where wall rim joist would be located in the absence of a cantilever. Insulation is placed on both sides of this block.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
N. Attached Porch Roof Insulation
01 The exterior insulated wall at the intersection with the porch roof is fully insulated above, below and behind the roof line.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 7 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
N. Attached Porch Roof Insulation
02 Where truss framing is used, airtight blocking is at the top and bottom of each wall/roof section and insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
INSULATION INSTALLATION CF2R-ENV-03-E
(Page 8 of 8)
Registration Number: 424-P010143661A-000-002-E03004A-0000 Registration Date/Time: 2025-01-06 15:58:40 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:25
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Jessica Ortiz
Documentation Author Signature:
Company:
TruTeam of California
Signature Date:
2025-01-06
Address:
260 Jimmy Ann Drive
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Daytona Beach FL 32114
Phone:
386-304-2222
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this
statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all
applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the
enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made
available to the enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
Jessica Ortiz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
TruTeam of California
Position With Company (Title):
Address:
260 Jimmy Ann Drive
CSLB License:
1034361
City/State/Zip:
Daytona Beach FL 32114
Phone:
386-304-2222
Date Signed:
2025-01-06
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-P01002A-0000 Registration Date/Time: 2025-01-02 15:03:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-02 15:04:34
PHOTOVOLTAIC SYSTEMS CF2R-PVB-01-E
(Page 1 of 4)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. General Information
01 Project Location (City)La Quinta 02 Building type Single family
03 Climate Zone 15 04 Method of Compliance:Performance
05 Qualifying Exceptions NA 06 Community Solar n/a
B. Design Photovoltaic Systems Information
01 02 03 04 05 06 07 08 09 10 11 12 13
PV Array ID
or Name
Adjusted
Minimum PV
Size (kW)
Adjusted
Value from
Exception
Module Type CFI Azimuth
(deg)
Tilt Input
(deg/Pitch)Angle/Tilt Annual Solar
Access (%)
Inverter
Efficiency (%)
Shading
Requirement
Compliance
Path
Array Type
Module Level
Power
Eletronics
1 6.05 6.05 Premium
(~18-20%)true 180 Pitch 4 97 97.5
Minimal
Shading
Critierion
Fixed Microinverte
rs
14 Total DC System Size (kW)6.05
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
PHOTOVOLTAIC SYSTEMS CF2R-PVB-01-E
(Page 2 of 4)
Registration Number: 424-P010143661A-000-002-P01002A-0000 Registration Date/Time: 2025-01-02 15:03:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-02 15:04:34
C. Installed Photovoltaic Systems Information
01 02 03 04 05 06 07 08 09 10
PV Array ID or
Name
DC System Size
(kW)Module Type Azimuth (deg)Tilt Input
(deg/Pitch)Angle/Tilt Annual Solar
Access (%)
Inverter Efficiency
(%)Array Type Module Level
Power Eletronics
1 6.71 n/a 180 Pitch 4 97 97.5 Fixed Microinverters
11 Total DC System Size (kW)6.71
D. Solar Access Verification
01
The installer shall provide documentation that demonstrates the shading condition of the actual installation of the PV module is consistent with the annual solar access % in Table B. The
verification must be done by measurements from an approved solar assessment tool or other CEC approved alternative methods. The satellite, drone or other digital image of the
obstructions that cast shadows on the PV array must be created and dated after the installation of the photovoltaic system. If the image is dated before the installation, then additional
on-site pictures must be attached to clearly show that the installed system matches the system modeled in the solar assessment report.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
E. System Monitoring Requirements
All installed PV systems must have a working web based portal and a mobile device application provide access to the following information:
01 Nominal kW rating of the PV system
02 Number of PV modules and nominal watt rating of each module
03 Hourly (or 15 min), daily, monthly and annual kWh production in numeric and graphic format
04 Running toal of daily kWh production
05 Daily kW peak power production
06 Current kW production of the entire PV system
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
F. Qualifying Exception Requirement
This section does not apply to this project.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
PHOTOVOLTAIC SYSTEMS CF2R-PVB-01-E
(Page 3 of 4)
Registration Number: 424-P010143661A-000-002-P01002A-0000 Registration Date/Time: 2025-01-02 15:03:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-02 15:04:34
G. SMUD Solar Share Program
This section does not apply to this project.
H. Compliance Statement
01 Pass - dwelling does comply with the Photovoltaic System requirements
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
PHOTOVOLTAIC SYSTEMS CF2R-PVB-01-E
(Page 4 of 4)
Registration Number: 424-P010143661A-000-002-P01002A-0000 Registration Date/Time: 2025-01-02 15:03:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-02 15:04:34
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
America Flores
Documentation Author Signature:
Company:
Sunrun Installation Services Inc
Signature Date:
2025-01-02
Address:
225 Bush St, Suite 1400
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
San Francisco CA 94104
Phone:
(855) 478-6786
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this
statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all
applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the
enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made
available to the enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
America Flores
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Sunrun Installation Services Inc
Position With Company (Title):
Address:
225 Bush St, Suite 1400
CSLB License:
750184
City/State/Zip:
San Francisco CA 94104
Phone:
(855) 478-6786
Date Signed:
2025-01-02
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-C01007A-0000 Registration Date/Time: 2025-01-07 10:14:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:11
ELECTRIC READY REQUIREMENTS CF2R-ELC-01-E
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. General Information
1 Project Scope
Electric Cooktop Ready (For systems using gas or proprane cooktop)
Electric Clothes Dryer Ready - Systems Serving Individual Dwelling Units (Clothes dryers
with gas or proprane plumbing)
Heat Pump Space Heater Ready (For systems using gas or proprane furnace)
B. Energy Storage System Ready
01 ESS Ready interconnection equipment with minimum backed up of 60 amps and 4 ESS branch circuits, OR A dedicated raceway from the main service to a panelboard (subpanel). The
panelboard that supplies the branch circuits (subpanel) must be labeled "Subpanel shall include all backed-up load circuits."
02 A minimum of four branch circuits shall be identified and have their source of supply collocated at a single panelboard suitable to be supplied by the ESS. At least one circuit shall supply
the refrigerator, one lighting circuit near the primary egress, and at least one circuit shall supply a sleeping room receptacle outlet.
03 The main panelboard shall have a minimum busbar rating of 225 amps.
04 Sufficient space shall be reserved to allow future installation of a system isolation equipment/transfer switch within 3 feet of the main panelboard.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
C. Heat Pump Space Heater Ready
01 A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the furnace and accessible to the furnace with no obstructions.
02 The branch circuit conductors shall be rated at 30 amps minimum.
03 The blank cover shall be identified as "240V ready".
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
ELECTRIC READY REQUIREMENTS CF2R-ELC-01-E
(Page 2 of 3)
Registration Number: 424-P010143661A-000-002-C01007A-0000 Registration Date/Time: 2025-01-07 10:14:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:11
C. Heat Pump Space Heater Ready
04 All electrical components shall be installed in accordance with the California Electrical Code
05 The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future heat pump space heater installation. The reserved
space shall be permanently marked as "For Future 240V use".
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
D. Electric Cooktop Ready
01 A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the cooktop and accessible to the cooktop with no obstructions.
02 The branch circuit conductors shall be rated at 50 amps minimum.
03 The blank cover shall be identified as "240V ready".
04 All electrical components shall be installed in accordance with the California Electrical Code
05 The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future electric cooktop installation. The reserved space
shall be permanently marked as "For Future 240V use".
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
E. Electric Clothes Dryer Ready
01 A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the clothes dryer location and accessible to the clothes dryer location with no obstructions.
02 The branch circuit conductors shall be rated at 30 amps minimum.
03 The blank cover shall be identified as "240V ready".
04 All electrical components shall be installed in accordance with the California Electrical Code
05 The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future electric clothes dryer installation. The reserved
space shall be permanently marked as "For Future 240V use".
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
ELECTRIC READY REQUIREMENTS CF2R-ELC-01-E
(Page 3 of 3)
Registration Number: 424-P010143661A-000-002-C01007A-0000 Registration Date/Time: 2025-01-07 10:14:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:11
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Marcos Olvera
Documentation Author Signature:
Company:
Schamber Electric
Signature Date:
2025-01-07
Address:
1674 Railroad Street
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92880
Phone:
951-739-0497
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this
statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all
applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the
enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made
available to the enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
Marcos Olvera
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Schamber Electric
Position With Company (Title):
Address:
1674 Railroad Street
CSLB License:
957709
City/State/Zip:
Corona CA 92880
Phone:
951-739-0497
Date Signed:
2025-01-07
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-E20021A-0000
Registration Date/Time: 2025-02-14 15:16:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:17:29
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF2R-ENV-20-H
(Page 1 of 4)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Enclosure Air Leakage - General Information
01 Is HERS verification of building enclosure air leakage to outside
required by CF1R?
Required
02 Target Enclosure Air Leakage from CF1R (CFM50)1860
03 Indoor Temperature During Test (degrees Fahrenheit ( °F))70
04 Outdoor Temperature During Test (degrees Fahrenheit ( °F))70
05 Blower Door Location Front Door
06 Building Elevation Above Sea level (feet (ft))56
07 Date of Diagnostic Test for this Dwelling 2025-02-13
08 Test Procedure Used Single-Point Test with Manual Meter
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF2R-ENV-20-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-E20021A-0000
Registration Date/Time: 2025-02-14 15:16:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:17:29
B. Diagnostic Equipment Information
01 Number of Manometers Used to Measure Home Pressurization 1
02 03 04 05 06
Manometer Make Manometer Model Manometer Serial
Number
Manometer Calibration
Date
Manometer Calibration
Status
Retrotec DM32-10A 405286 2025-02-01 Manometer Calibration is
valid
07 Number of Fans Used to Pressurize Home 1
08 09 10 11
Fan Make Fan Model Fan Serial Number Fan Configuration (rings)
Retrotec 1000 1 b4
ENV20a - Single Point Air Tightness Test With Manual Meter
C. Enclosure Air Leakage Diagnostic Test
01 Time Average Period of Meter (seconds)10
02 Test Methodology Depressurization
03 Pre-test Baseline Enclosure Pressure (Pa) (may be positive or
negative)
0.3
04 Unadjusted Enclosure Pressure Target (Pa)-49.7
05 Unadjusted Enclosure Pressure Measured (Pa) (Pressurization is
positive; Depressurization is negative)
50
06 Induced Enclosure Pressure Difference (Pa) Goal = 50 +- 3
(Pressurization is positive; Depressurization is negative)
49.7
07 Induced Enclosure Pressure Check Induced pressure within range for single point test
08 Measured Nominal Fan Flow at Above Fan Pressure (cfm) at the
Induced Enclosure Pressure Difference (in C06 above)
1630
09 Calculated Nominal CFM50 1636
D. Altitude and Temperature Correction
01 Altitude and Temperature Correction Factor 0.998
02 Corrected CFM50 1633
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF2R-ENV-20-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-E20021A-0000
Registration Date/Time: 2025-02-14 15:16:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:17:29
E. Accuracy Adjustment
01 Adjusted CFM50 (measured air leakage rate)1796
F. Compliance Statement
01 Passes Enclosure Air Leakage Test
G. Additional Requirements For Compliance
01 The procedure for preparing the enclosure for testing is detailed in RESNET 380-2019 Section 3.2.
02 The procedure for installation of the test apparatus, and preparations for measurement shall conform to RESNET 380-2019 Section 3.3
03 The procedure for the conduct of the enclosure air leakage test shall conform to the One-Point Airtightness Test specified in RESNET
380-2019 Section 3.4.1
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF2R-ENV-20-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-E20021A-0000
Registration Date/Time: 2025-02-14 15:16:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:17:29
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Signature Date:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Raymond Weden (authorized Steven Bryant)
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
Richmond American Homes of California Inc - SoCal
Position With Company (Title):
Director of Purchasing
Address:
5171 California Ave, Suite 120
CSLB License:
487535
City/State/Zip:
Irvine CA 92617
Phone:
949-467-2261
Date Signed:
2025-02-14
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-E21005A-0000
Registration Date/Time: 2025-01-06 15:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:33
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF2R-ENV-21-H
(Page 1 of 5)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Air Barrier Materials
01
A continuous sealed exterior air barrier is required in all thermal envelope assemblies to limit air movement between unconditioned/
outside spaces and conditioned/ inside spaces, and must comply using one of the following methods:
1.Using individual materials that have an air permeance not exceeding 0.004 cfm/ft2 under a pressure differential of 0.3 in. w.g.
(1.57 pcf) (0.02 L/s.m2 at 75 pa) when tested in accordance with ASTM E2178; or
2.Using assemblies of materials and components that have an average air leakage not to exceed 0.04 cfm/ft2 under a pressure
differential of 0.3 in. w.g. (1.57 pcf) (0.2 L/s.m2 at 75 pa) when tested in accordance with ASTM E2357, ASTM E1677, ASTM E1680,
or ASTM E283; or
3.Testing the complete building and demonstrating that the air leakage rate of the building envelope does not exceed 0.40 cfm/ft 2
under a pressure differential of 0.3 in. w.g. (1.57 pcf) (2.0 L/s.m2 at 75 pa) when tested in accordance with ASTM E779 or an
equivalent approved method.
02 Method of Compliance Method 1 (Individual Materials)
Note:
SPF insulation is an acceptable air barrier and sealant when installed to a minimum thickness of 2 inches for closed cell and 5.5 inches for
open cell, except where not allowed by manufacturer (e.g. flues, vents, can lights, etc).
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
B. Raised Floor Adjacent to Unconditioned Space or Separate Dwelling Units
01 All gaps in the raised floor are sealed.
02 All chases sealed at floor level using a sealed hard cover.
03 All holes (e.g. for plumbing and electrical wires) that penetrate the floor or bottom plates of walls are sealed.
04 Subfloor sheathing is glued or sealed at all panel edges to create a continuous airtight subfloor air barrier.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
C. Walls Adjacent to Unconditioned Space
01 All penetrations through the exterior wall air barrier are sealed to provide an airtight envelope to unconditioned spaces such as the
outdoors, attic, garage and crawl space.
02 Exterior wall air barrier is sealed to the top plate and bottom plate in each stud bay.
03 All electrical boxes, including knockouts that penetrate the air barrier to unconditioned space are sealed.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF2R-ENV-21-H
(Page 2 of 5)
Registration Number:
424-P010143661A-000-002-E21005A-0000
Registration Date/Time: 2025-01-06 15:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:33
C. Walls Adjacent to Unconditioned Space
04 All openings in top and bottom plate, including all interior and exterior walls, to unconditioned space are sealed; such as holes drilled for
electrical and plumbing.
05 Exterior bottom plates (all stories) are sealed to the floor.
06 All gaps around windows and doors are sealed. The sealant used follows manufacturer specifications.
07 Rim joist gaps and openings are fully sealed.
08 Fan exhaust duct outlet/ damper at the exterior wall are sealed.
09 Knee walls have solid and sealed blocking at the bottom, top, left and right sides to prevent air movement into insulation.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
D. Ceiling Air Barrier Adjacent to Unconditioned Space
01 There is a continuous air barrier at the ceiling level. All openings into walls, drops, chases or double walls are sealed.
02 All penetrations through the top plate of interior and exterior walls are sealed.
03 Fire sprinklers penetrating a ceiling air barrier shall be sealed to prevent air movement according to the manufacturer's instructions.
04
All fixtures cut into the ceiling air barrier (e.g. HVAC registers, electrical boxes, fire alarm boxes, exhaust fan housing, and recessed lighting
fixtures) are sealed to the surrounding dry wall. If it is not possible to seal the fixture directly, a secondary air barrier shall be created
around the fixture.
05 All installed recessed lighting fixtures that penetrate the ceiling to unconditioned space are rated to be Insulation Contact and Airtight (IC
and AT) which allow direct contact with insulation.
06 All dropped ceiling areas are covered with hard covers that are sealed to the framing, or else the bottom and sides of dropped ceiling
areas are all insulated and sealed as ceilings and walls as required on the Certificate of Compliance.
07 All vertical chases (e.g. HVAC ducts and plumbing) and soffits are sealed at the ceiling level.
08 Chimneys and flues require sheet metal flashing at the ceiling level. The flashing shall be sealed to the chimney/flue with fire rated caulk.
The flashing shall be sealed to the surrounding framing.
09 Framing locations where air may move down into the walls from the attic (e.g. double walls, pocket doors, architectural bump-outs, etc)
have a sealed hard cover to prevent air movement.
10 Attic access forms an airtight seal between the conditioned space and unconditioned space. Vertical attic access requires mechanical
compression using screws or latches.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
E. Roof Air Barrier - Unvented Attics Adjacent to Unconditioned Space
01 There is a continuous air barrier at the roof deck and gable ends.
02 Chimneys and flues require sheet metal flashing at the roof deck. The flashing shall be sealed to the chimney/flue with fire rated caulk.
The flashing shall be sealed to the surrounding framing.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF2R-ENV-21-H
(Page 3 of 5)
Registration Number:
424-P010143661A-000-002-E21005A-0000
Registration Date/Time: 2025-01-06 15:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:33
E. Roof Air Barrier - Unvented Attics Adjacent to Unconditioned Space
03 All penetrations in the roof deck and gable ends for plumbing, electrical, etc. are sealed.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
F. Conditioned Space Above Or Adjacent To Garage Air Barrier
01 All penetrations in the subfloor above the garage into conditioned space must follow the raised floor air barrier requirements above.
02
Infiltration between the space above the garage and subfloor is prevented by one of the following methods:
•Seal all edges of garage ceiling (typically drywall) at the perimeter of the garage to create a continuous airtight surface between
the garage and adjacent conditioned envelope. Seal all plumbing, electric and mechanical penetrations between the garage and
the adjacent conditioned space. For an open-web truss, airtight blocking is added on four sides of the garage perimeter. Insulation
can be placed on the garage ceiling.
•Seal the band joist above the wall at the garage to conditioned space transition. Seal all subfloor seams and penetrations between
the garage and adjacent conditioned space. Insulation must be placed in contact with the subfloor below the conditioned space.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
G. Cantilevered Floor Air Barrier
01 Airtight blocking is installed between joists where the wall rim joist would have been located in the absence of a cantilever.
02 Exterior sheathing is installed to the bottom of the cantilever so that there is a continuous air and weather barrier for the cantilever. The
cantilevered joist must be insulated to the same R value as would be required for the subfloor prior to closing.
03 Any gaps, cracks or penetrations in the air barrier of the cantilever are sealed. Recessed can lights in the cantilever are rated to be
Insulation Contact and Airtight (IC and AT) and properly sealed to the sheathing.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
H. Walls For Attached Porch, Attic, Double Wall Air Barrier
01 An exterior wall air barrier is required at the intersection of the porch and exterior wall when there is conditioned space on the other
side. The exterior wall includes an air barrier where the attic attaches to the conditioned space.
02 Truss framing blocking is used at the top and bottom of each wall/ roof section.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
I. Special Requirements for SIPs
01 SIPs are considered an air barrier when properly sealed at top, bottom, sides and all penetrations.
02 Air barrier is continuous across all surfaces, including between SIPs and non-SIP sections.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF2R-ENV-21-H
(Page 4 of 5)
Registration Number:
424-P010143661A-000-002-E21005A-0000
Registration Date/Time: 2025-01-06 15:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:33
J. Special Requirements for ICF
01 ICF sections are considered an air barrier when properly sealed at top, bottom, sides and all penetrations.
02 Air barrier is continuous across all surfaces, including between ICF and non-ICF sections.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF2R-ENV-21-H
(Page 5 of 5)
Registration Number:
424-P010143661A-000-002-E21005A-0000
Registration Date/Time: 2025-01-06 15:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:33
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Jessica Ortiz
Documentation Author Signature:
Company:
TruTeam of California
Signature Date:
2025-01-06
Address:
260 Jimmy Ann Drive
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Daytona Beach FL 32114
Phone:
386-304-2222
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Jessica Ortiz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
TruTeam of California
Position With Company (Title):
Address:
260 Jimmy Ann Drive
CSLB License:
1034361
City/State/Zip:
Daytona Beach FL 32114
Phone:
386-304-2222
Date Signed:
2025-01-06
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-E22006A-0000
Registration Date/Time: 2025-01-06 15:59:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:53
QII - INSULATION INSTALLATION CF2R-ENV-22-H
(Page 1 of 6)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Insulation Materials Installed
01 Roof Deck Insulation Material Installed n/a
02 Ceiling Insulation Material Installed n/a
03 Exterior Wall Insulation Material Installed Batt and Blanket
04 Raised Floor Insulation Material Installed n/a
05 Slab Edge Insulation Material Installed n/a
B. All Surfaces
01 Air barrier installation and preparation for insulation was done and verified prior to insulation being installed.
02 All surfaces between conditioned and unconditioned space are sealed and insulated to meet or exceed the levels specified on the
Certificate of Compliance
03
All structural framing areas shall be insulated in a manner that resists thermal bridging through the assembly separating conditioned from
unconditioned space. Structural bracing, tie-downs, and framing of steel, or specialized framing used to meet structural requirements of
the California Building Code (CBC) are allowed and must be insulated. These areas shall be called out on the building plans with diagrams
and/ or specified design drawings indicating the R-value of insulation and fastening method to be used.
04 All insulation was installed according to the manufacturer's installation instructions.
05 Labels or specification/ data sheets for each insulation material shall be provided to the HERS rater. Loose-fill material includes insulation
material bag labels or coverage charts.
06
Loose-fill insulation - the installed depth and density of insulation is verified in at least 6 random locations to ensure that the minimum
thickness and installed density meet R-value specified on the Certificate of Compliance, and are consistent with the manufacturer's
coverage chart.
07 If kraft paper faced insulation is used, paper is installed on the conditioned (warm in winter) side of surface. Paper must be in contact
with air barrier to within 2-inches of the framing (stud, joists, etc.).
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
C. Raised Floor Adjacent to Unconditioned Space
01 Insulation is in full contact with the subfloor.
02 Insulation hangers are spaced at 18 inches or less. Insulation hangers do not compress insulation.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF2R-ENV-22-H
(Page 2 of 6)
Registration Number:
424-P010143661A-000-002-E22006A-0000
Registration Date/Time: 2025-01-06 15:59:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:53
C. Raised Floor Adjacent to Unconditioned Space
03 Netting, or mesh, can be used if the cavity under the floor is filled and in contact with the subfloor.
04 When daylit basements are adjacent to crawlspaces, if the basement is conditioned the walls adjacent to the crawlspace are insulated to
the R-value listed on the Certificate of Compliance. This includes framed stem walls, and vertical concrete retaining walls.
05 If access to the crawlspace is from the conditioned area the raised floor includes an airtight insulated access hatch. Where possible locate
crawl space access on the exterior.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
D. Walls Adjacent to Unconditioned Space
01 Insulation quality was verified prior to the installation of the interior air barrier (typically gypsum board).
02
Loose-fill and batt insulation is in contact with all six sides of wall cavities (top, bottom, back, left, right, front [to be installed later]) with
no gaps, voids or compression. Special Situation: Where framing depth is greater than required insulation thickness (e.g., double walls or
framed bump-outs) a secondary air barrier shall be installed and in contact with the insulation, so that the insulation fills the cavity
formed by the additional air barrier.
03 Insulation fits snuggly around obstructions (e.g., electrical boxes, plumbing and wiring) with no gaps, voids or compression.
04 Structural metal tie-downs and shear panels are insulated between exterior air barrier and metal.
05 Hard to access wall stud cavities, such as corner channels or wall intersections, are insulated to the proper R-value prior to the installation
of exterior sheathing or exterior stucco lathe.
06 Insulation and interior air barrier are installed behind tub, shower, fireplace enclosures and stairwells to the R-value listed on the
Certificate of Compliance when located against exterior walls.
07
All single-member window and door headers shall be insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a
minimum of R-5 for all other assemblies. No header insulation is required for single-member headers that are the same width as the wall,
provided that the entire wall has at least R-2 insulation.
08 After insulation is installed: All insulated walls have interior and exterior air barriers, including kneewalls and walls of skylight wells.
Exception: Rim joists. Interior air barrier (typically gypsum board) is sealed to top plate.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
E. Ceiling Adjacent to Unconditioned Space
01 Insulation extends to the outside surface of the exterior wall.
02 Insulation is in direct contact with the ceiling air barrier so there are no gaps, voids or compression.
03
Chimneys and flues (except zero clearance) have a sheet metal collar at the ceiling level to prevent contact with the insulation. The collar
is at least as tall as the depth of the insulation. There is a minimum 1-inch clearance between the collar and the chimney/flue for double
wall vent, and 6-inches for single wall vent, unless manufacturer's instructions require otherwise. The collar is sealed to the ceiling with
high temperature sealant to prevent air leakage. The insulation is in contact with the sheet metal collar.
04 Recessed can lights penetrating the ceiling air barrier are covered with insulation to the depth needed to meet the ceiling R-value
specified on the Certificate of Compliance.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF2R-ENV-22-H
(Page 3 of 6)
Registration Number:
424-P010143661A-000-002-E22006A-0000
Registration Date/Time: 2025-01-06 15:59:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:53
E. Ceiling Adjacent to Unconditioned Space
05 External surfaces of steel studs, steel-framed kneewalls, skylight shafts, and gable ends are covered with insulation.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
F. Ceiling Insulation in Vented Attics
01 Required eave ventilation shall not be obstructed. The net-free ventilation area of the eave vent is maintained.
02 Eave vent baffles and dams are installed to prevent air movement under or into the ceiling insulation.
03 Attic access is insulated to the same R-value required by the Certificate of Compliance for ceiling insulation and the insulation is
permanently attached using adhesive or mechanical fasteners.
04 Attic access must have a dam around the access to at least the same depth as the insulation.
05
Attic rulers specified to the installed loose-fill material (brand and type) are installed and evenly distributed throughout the attic to verify
depth (one ruler for every 250 square feet (ft2)). The rulers are clearly readable and scaled to read inches of insulation and the R-value
installed.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
G. Insulation in unvented Attics
01 The roof sheathing is the air barrier and is sealed to prevent air movement to the outside.
02 Insulation is in full contact with the air barrier (roof sheathing).
03 If insulated using air permeable insulation, gable end walls are sealed and insulated the same as exterior walls, including interior air
barrier.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
H. Insulation in Vented Attics (High Performance Vented Attics)
01 Insulation is in full contact with roof sheathing and firmly supported to prevent sagging.
02 Batt insulation between roof trusses is acceptable with minimal gaps and voids caused by roof truss members.
03 Insulation is not required on gable end walls.
04
Required roof deck insulation over any conditioned space, or HVAC ducts, is installed on the entire attic roof deck; even over
unconditioned spaces (e.g., garage, covered porch). Roof deck of attic over unconditioned space without HVAC ducts and separated from
other attics by a sealed air barrier do not need to be insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
I. Special Requirements for Skylight Shafts and Attic Knee Walls
01 Insulation must meet all the requirements for walls and insulation is in contact with the air barrier on all six sides unless SPF is used.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF2R-ENV-22-H
(Page 4 of 6)
Registration Number:
424-P010143661A-000-002-E22006A-0000
Registration Date/Time: 2025-01-06 15:59:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:53
I. Special Requirements for Skylight Shafts and Attic Knee Walls
02 Insulation shall be in full contact with the interior wall finish. Batt insulation must be cut to fit around 2x4's that are laid flat.
03 Skylight shafts and attic knee walls shall be completely enclosed by vertical and horizontal framing, including horizontal plates at the top
and bottom of the insulation.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
J. Special Requirements for Floors Above Garages
01 If the air barrier is at the perimeter of the garage below the conditioned subfloor, then the insulation may be placed on the garage ceiling.
The perimeter of the subfloor must also be insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
K. Special Requirements for Cantilevered Floors
01 Sealed blocking shall be installed between joists where the wall rim joist would have been located in the absence of a cantilever.
Insulation shall be placed on both sides of the block.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
L. Special Requirements for Attached Porches
01 Exterior wall at the intersection of the porch roof is fully insulated above, below and behind the roof line.
02 Where truss framing is used, airtight blocking is used at the top and bottom of each wall/ roof section and is insulated.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
M. Special Requirements for SPF Insulation
01 Installed product meets the claimed R-value per inch. The total R-value may be calculated based on the thickness of insulation multiplied
by the "tested R-value per inch" as certified by the Department of Consumer Affairs, Bureau of Household Goods and Services.
02 Installed thickness meets the required R-value from the Certificate of Compliance. Verified in at least 6 random places for each surface
type: floors, walls and ceilings.
03 Insulation is spray applied to fully adhere to structural assembly framing, floor and ceiling joists, and other framing surfaces within the
construction cavity.
04 If multiple layers are applied, each foam lift (e.g., spray application) adheres to the substrate and foam interfaces.
05 Closed cell SPF: In area where an air barrier is required the foam is at least 2-inches thick.
06 Open cell SPF: In area where an air barrier is required the foam is at least 5.5-inches thick.
07 Open cell SPF: Depressions in the foam insulation are not greater than 1/2-inch of the required thickness provided these depressions do
not exceed 10% of the surface area being insulated.
08 Open cell SPF: Insulation completely fills cavities of 2x4 framing.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF2R-ENV-22-H
(Page 5 of 6)
Registration Number:
424-P010143661A-000-002-E22006A-0000
Registration Date/Time: 2025-01-06 15:59:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:53
M. Special Requirements for SPF Insulation
09
SPF insulation is not applied directly to recessed lighting fixtures unless specifically allowed by manufacturer's instructions. when not
allowed, can lights are:
A.Covered with a minimum of 1.5-inches of mineral fiber insulation or
B.Enclosed in a manufacturer's approved box fabricated from an approved material, such as 18 gauge sheet metal or 1/2-inch
gypsum board.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF2R-ENV-22-H
(Page 6 of 6)
Registration Number:
424-P010143661A-000-002-E22006A-0000
Registration Date/Time: 2025-01-06 15:59:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-06 15:59:53
Documentation Author's Declaration Statement
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Jessica Ortiz
Documentation Author Signature:
Company:
TruTeam of California
Signature Date:
2025-01-06
Address:
260 Jimmy Ann Drive
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Daytona Beach FL 32114
Phone:
386-304-2222
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept
responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work
identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible
person and attest to the declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation
conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and
specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am
required to offer any necessary corrective action at no charge to the building owner.
5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of
Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Jessica Ortiz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
TruTeam of California
Position With Company (Title):
Address:
260 Jimmy Ann Drive
CSLB License:
1034361
City/State/Zip:
Daytona Beach FL 32114
Phone:
386-304-2222
Date Signed:
2025-01-06
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-L01008A-0000
Registration Date/Time: 2025-01-07 10:14:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:22
LIGHTING SINGLE FAMILY DWELLINGS CF2R-LTG-01-E
(Page 1 of 5)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Installed Lighting and Controls
Select Yes or No according to whether your work on the project includes each of the following types of lighting and controls. See sections B
through H for applicable requirements.
01 High Luminous Efficacy luminaires installed in any interior rooms.
(See Section B.)
Yes
02 JA8 compliant luminaires installed in any interior rooms. (See
Section B.)
Yes
03 Recessed downlight luminaires in ceilings in any interior room (See
Section C).
Yes
04 Light Sources in Enclosed or Recessed Luminaires (See Section D.)No
05 Lighting controls in bathrooms (See Section E.)Yes
06 Lighting controls in laundry rooms (See Section E.)Yes
07 Lighting controls in utility rooms (See Section E.)Yes
08 Lighting controls in garage (See Section E.)Yes
09 Lighting controls in walk-in closets. (See Section E.)Yes
10 Lighting controls in interior rooms except bathrooms, laundry
rooms, utility rooms, and garages. (See Section E2.)
Yes
11 Screw Based luminaires. (See Section F.)Yes
12 Internally illuminated address signs. (See Section G.)Yes
13 Outdoor lighting and controls (See Section H.)Yes
14 Parking Garages for eight or more Vehicles (See Section I)No
15 Blank Electrical Boxes installed more than 5 feet from finished floor
(See Section J)
Yes
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
LIGHTING SINGLE FAMILY DWELLINGS CF2R-LTG-01-E
(Page 2 of 5)
Registration Number:
424-P010143661A-000-002-L01008A-0000
Registration Date/Time: 2025-01-07 10:14:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:22
B. High Luminous Efficacy Luminaires
01
150.0(k)1A and Table 150.0-A: All luminaires are installed with:
•Light sources of one of the lighting technologies specified under the "High Luminous Efficacy" column of Table 150.0-A; or
•JA8 compliant light sources and the light sources are marked with a label reading "JA8-2022" or "JA8-2022-E".
.
Exception 1: Integrated device lighting: Lighting integral to exhaust fans, kitchen range hoods, bath vanity mirros, and garage door
openers, and non-removable lighting attached to ceiling fans.
Exception 2: Navigation Lighting: Night lights, step lights, path lights less than 5 watts.
Exception 3: Cabinet Lighting: Lighting internal to drawers, cabinetry, and linen closets with an efficacy of 45 lumens per watt or greater.
02 •Lighting shall have readily accessible wall-mounted controls that allow the lighting to be manually turned ON and OFF.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
C. Recessed Downlight LuminaIres in Ceilings
01 150.0(k)1Ci: Do not contain screw based lamp sockets.
02 The luminaire is marked with "JA8-2022".
03
150.0(k)1Cii: Has label certifying the luminairea are air tight with air leakage less than 2.0 cfm at 75 Pascals when tested in accordance
with ASTM E283. Exception: Recessed luminaires marked for use in fire-rated installations, and recessed luminaires installed in
non-insulated ceilings.
04
150.0(k)1Ciii: Sealed with a gasket or caulk between the luminaire housing and ceiling, and all air leakage paths between conditioned and
unconditioned spaces are sealed with a gasket or caulk, or be installed per manufacturer's instructions to maintain airtightness between
the luminaire housing and ceiling. Exception: Recessed luminaires marked for use in fire-rated installations, and recessed luminaires
installed in non-insulated ceilings.
05
150.0(k)1Civ: Meet the following requirements (California Electrical Code Section 410.116). A recessed luminaire that is not identified for
contact with insulation shall have all recessed parts spaced not less than 1/2 inch from combustible materials. The points of support and
the trim finishing off the openings in the ceiling shall be permitted to be in contact with combustible materials. A recessed luminaire that
is identified for contact with insulation, Type IC, shall be permitted to be in contact with combustible materials at recessed parts, points of
support and portions passing through or finishing off the opening in the building structure. Thermal insulation shall not be installed above
a recessed luminaire or within 3 inches of the recessed luminaire's enclosure, wiring compartment, ballast, transformer, LED driver, or
power supply unless the luminaire is identified as Type IC for insulation contact.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
D. Light sources in enclosed or recessed luminaires (other than recessed downlight luminaires in ceilings)
This section does not apply to this project.
E. Lighting controls in bathrooms, garages, laundry rooms, utility rooms, and walk-in closets.
01 150.0(k)2E: In bathrooms, garages, laundry rooms, utility rooms and walk-in closets, at least one installed luminaire is controlled by an
occupancy or vacancy sensor providing automatic-off functionality.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
LIGHTING SINGLE FAMILY DWELLINGS CF2R-LTG-01-E
(Page 3 of 5)
Registration Number:
424-P010143661A-000-002-L01008A-0000
Registration Date/Time: 2025-01-07 10:14:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:22
F. Lighting Controls in any interior rooms
01 150.0(k)2Eii: For lighting internal to drawers and cabinetry with opaque fronts or doors, controls that turn light off when the drawer or
door is closed shall be provided.
02
150.0(k)2F: Lighting in habitable spaces, including but not limited to living rooms, dining rooms, kitchens, and bedrooms, have readily
accessible wall-mounted dimming controls that allow the lighting to be manually adjusted up and down. Forward phase cut dimmers
controlling LED light sources in these spaces shall comply with NEMA SSL 7A. EXCEPTION 1: Ceiling fans may provide control of integrated
lighting via a remote control. EXCEPTION 2:Luminaires connected to a circuit with controlled lighting power less than 20 watts; or
controlled by an occupancy or vacancy sensor providing automatic-off functionality . EXCEPTION 3: Navigation lighting such as night
lights, step lights, and path lights less than 5 watts, and lighting internal to drawers and cabinetry with opaque fronts or doors or with
automatic off controls.
03 150.0(k)2A Lighting has readily accessible wall-mounted controls that allow the lighting to be manually turned ON and OFF.
04 150.0(k)2B: No control bypasses a dimmer, occupancy sensor or vacancy sensor function where that dimmer or sensor has been installed
to comply with Section 150.0(k)
05 150.0(k)2C: Lighting controls comply with the applicable requirements in Section 110.9.
06
150.0(k)2D: An Energy Management Control System (EMCS) or a multiscene programmable control can be used to comply with dimming,
occupancy, and lighting control requirements in Section 150.0(k)2 if it provides the functionality of the specified control in accordance
with Section 110.9, and the physical controls (readily accessible wall-mounted controls that allow the lighting to be manually turned ON
and OFF).
07 150.0(k)2G: Independent Controls: Integrated lighting of exhaust fans is controlled independently from the fans. Undercabinet lighting,
undershelf lighting, interior lighting of display cabinets, and switched outlets are controlled separately from ceiling installed lighting.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
G. Screw Based Luminaires
01 150.0(k)1B: Screw based luminaires shall contain lamps that are marked with "JA8-2022" or "JA8-2022-E".
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
H. Address Signs
01
150.0(k)4: Internally illuminated address signs shall either:
•Comply with Section 140.8. Applicable nonresidential sign lighting compliance forms shall also be submitted, or
•Consume no more than 5 Watts of power.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
I. Outdoor lighting and Controls
01 150.0(k)1A and Table 150.0-A: High efficacy outdoor lighting or LED light sources are installed
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
LIGHTING SINGLE FAMILY DWELLINGS CF2R-LTG-01-E
(Page 4 of 5)
Registration Number:
424-P010143661A-000-002-L01008A-0000
Registration Date/Time: 2025-01-07 10:14:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:22
I. Outdoor lighting and Controls
02
150.0(k)3A: Outdoor lighting is controlled by a manual ON and OFF switch that permits one of the following automatic actions:
•Controlled be a photocell and either a motion sensor or an automatic time switch control;
•Controlled by an astronomical time clock control.
Controls that override to ON shall not be allowed unless the override automatically returns the automatic control to its normal operation
within 6 hours.
An energy management control that provides the specified lighting control functionality and complies with all requirements applicable to
the specified controls may be used to meet the above requirements.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
J. Lighting for Residential Garages for Eight or More Vehicles
This section does not apply to this project.
K. Blank Electrical Boxes
01
150.0(k)1E: The number of blank electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
other device, shall be no greater than the number of bedrooms. The electrical boxes must be served by a dimmer, a vacancy sensor, low
voltage wiring or fan speed control.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
LIGHTING SINGLE FAMILY DWELLINGS CF2R-LTG-01-E
(Page 5 of 5)
Registration Number:
424-P010143661A-000-002-L01008A-0000
Registration Date/Time: 2025-01-07 10:14:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-01-07 10:15:22
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Marcos Olvera
Documentation Author Signature:
Company:
Schamber Electric
Signature Date:
2025-01-07
Address:
1674 Railroad Street
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92880
Phone:
951-739-0497
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the
declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this
Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building
permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the
builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Marcos Olvera
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
Schamber Electric
Position With Company (Title):
Address:
1674 Railroad Street
CSLB License:
957709
City/State/Zip:
Corona CA 92880
Phone:
951-739-0497
Date Signed:
2025-01-07
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 1 of 10)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. General Information
01 Dwelling Unit Name Single Family Dwelling 02 Climate Zone 15
03 Dwelling Unit Total Conditioned
Floor Area (ft2)3066 04 Number of Space Conditioning
Systems in this dwelling unit.2
05 Certificate of Compliance Type Performance (CF1R-PRF)06 Method Used to Calculate HVAC
Loads (See Section 150.0(h))ACCA Manual J
07 Calculated Dwelling Unit
Sensible Cooling Load (Btu/h)60000 08 Calculated Dwelling Unit Heating
Load (Btu/h)80000
09 Dwelling Unit Number of
Bedrooms 4
MCH-01a - Space Conditioning Systems Ducts and Fans - For use with Performance Certificate of Compliance
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 2 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
B. Design Space Conditioning (SC) System Component Specifications from CF1R
This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project.
01 02 03 04 05 06 07 08 09 10 11
SC System
ID/Name from
parent CC-PRF
SC System Type Heating System
Type
Cooling System
Type
Central Fan
Ventilation
Cooling System
Type
Distribution
System Type
Required
Thermostat
Type
Low Leakage
Air-Handling
Unit (LLAHU)
Status
Bypass Duct
Status
Cooling Zoning
Type
Cooling System
Compressor
Speed
HVAC1
Heating and
cooling system
other
Central gas
furnace Central split AC Not a CFVCS Unconditioned
attic Setback Yes credit is
taken No Bypass Duct Not Zonal Single Speed
Notes:
C. Design Space Conditioning (SC) System Compliance Requirements from CF1R
This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project.
01 02 03 04 05 06 07 08 09 10 11 12 13
SC System ID/ Name
from parent CC-PRF
Heating
Efficiency
Type
Minimum
Heating
Efficiency
Value
Heat Pump
Heating
Capacity at
47 °F
Heat Pump
Heating
Capacity at
17 °F
Cooling
Efficiency
Type
Minimum
Cooling
Efficiency
SEER/SEER2
Minimum
Cooling
Efficiency
EER/EER2/CE
ER
Minimum
Cooling
System
Airflow Rate
(CFM/ton)
Maximum
Fan Efficacy
(W/CFM)
Modeled
Duct R-Value
Central Fan
Ventilation
Cooling
Airflow
Central Fan
Ventilation
Cooling Fan
Efficacy
HVAC1 AFUE 96 EER2/SEER2 15.2 12.5 350 0.45 R-6
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 3 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
D. Installed Space Conditioning (SC) System Component Information
01 02 03 04 05 06 07 08 09 10
SC System ID/
Name from
parent CC-PRF
SC System
Description of
Area Served
Conditioned Floor
Area Served by
the System (ft2)
Heating System
Type
Cooling System
Type
Number of Indoor
Units for this
System
Distribution
System Type
SC System
Thermostat Type
Cooling Zoning
Type
Cooling System
Compressor
Speed Type
HVAC1 living 1 3066 Central gas
furnace Central split AC 1 Unconditioned
attic Setback Not Zonal Single Speed
HVAC1 LIVING 2 0 Central gas
furnace Central split AC 1 Unconditioned
attic Setback Not Zonal Single Speed
Notes:
E. Installed Heating System Equipment Information (not heat pumps)
01 02 03 04 05 06 07 08 09 10 11
SC System ID/
Name from
parent
CC-PRF
SC System
Description of
Area Served
Indoor Unit
Name or
Description of
Area Served
Does Indoor
Unit Provide
CFI IAQ
Ventilation?
Indoor Unit
Duct Status
Heating
Efficiency
Type
Heating
Efficiency
Value
Heating Unit
Manufacturer
Heating Unit Model
Number
Heating Unit Serial
Number
Rated Heating
Capacity,
Output
(Btu/h)
HVAC1 living 1 living 1 No Ducted > 10ft
length AFUE 96 GOODMAN GM9S960805 NA 80000
HVAC1 LIVING 2 LIVING 2 No Ducted > 10ft
length AFUE 96 GOODMAN GM9S960603 NA 60000
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 4 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
F. Installed Cooling System Outdoor Condensing Unit or Package Unit Equipment Information (not heat pumps)
01 02 03 04 05 06 07 08 09 10
SC System
ID/Name
from parent
CC-PRF
SC System
Description
of Area
Served
Cooling
Efficiency
SEER/SEER2
Cooling
Efficiency
EER/EER2/CE
ER
Condenser or Package Unit
Manufacturer
Condenser or Package Unit
Model Number
Condenser or Package Unit
Serial Number
System
Cooling
Capacity at
Design
Conditions
(Btu/h)
Condenser
Nominal
Capacity
(ton)
Condenser
Rated
Cooling
Capacity
(Btu/h))
HVAC1 living 1 15.2 12.5 GOODMAN GSXH506010 NA 60000 5 60000
HVAC1 LIVING 2 15.2 12.5 GOODMAN GSXH503010 NA 30000 2.5 30000
Notes:
G. Installed Split System Indoor Unit ( Coil or Fan Coil) Equipment Information - applicable to DX or hydronic heating or cooling, coils and fan coil units.
Systems with more than one indoor unit coil or fan coil unit (e.g. multi-split systems) shall provide information for each of the system indoor coils or fan coil units.
01 02 03 04 05 06 07 08 09 10
SC System ID/ Name
from parent CC-PRF
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Indoor Unit
Type
Indoor Unit
Duct Status
Does Indoor
Unit Provide
CFI IAQ
Ventilation?
Indoor Unit Manufacturer Indoor Unit Model Number Indoor Unit Serial Number
Indoor Unit
Nominal
Cooling
Capacity
(ton)
HVAC1 living 1 living 1 AC Coil Ducted > 10ft
length No GOODMAN CP61C34 NA
HVAC1 LIVING 2 LIVING 2 AC Coil Ducted > 10ft
length No GOODMAN CP37E34 NA
Notes:
H. Installed Heat Pump System - Split System Condensing Unit or Package Unit Equipment Information
This section does not apply to this project.
I. Installed Heat Pump System -Efficiency and Performance Compliance Information
This section does not apply to this project.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 5 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
J. Installed Duct System Information
01 02 03 04 05 06 07 08 09 10 11 12 13 14
SC System
ID/ Name
from parent
CC-PRF
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Supply Duct
Location
Supply Duct
R-Value
Return Duct
Location
Return Duct
R-Value
Exception
from Min
R-Value
Method of
compliance
with Airflow
and Fan
Efficacy
Req's in
150.0(m)13
Bypass Duct
Status
Number of
Air Filter
Devices on
Indoor Unit
Can
Approved
Airflow
Protocols be
used to test
this System?
Can
Approved
Fan Efficacy
Protocol be
used to test
this System?
Total Duct
Length
HVAC1 living 1 living 1 Uncondition
edAttic R6 Uncondition
edAttic R6 NoException
HERS_FanEff
icacyAirflow
Rate
false 1 Yes Yes DuctsGT10F
t
HVAC1 LIVING 2 LIVING 2 Uncondition
edAttic R6 Uncondition
edAttic R6 NoException
HERS_FanEff
icacyAirflow
Rate
false 1 Yes Yes DuctsGT10F
t
K. Installed Air Filter Device Information
Mandatory requirements for air filter devices are specified in Section 150.0(m)12. The installer shall place a sticker in or near each filter grille that displays the design airflow
rate for that filter grille/rack and the maximum allowed clean filter pressure drop at the design airflow rate. This will inform the occupant of the airflow vs pressure drop
performance required for replacement air filters.
01 02 03 04 05 06 07 08 09 10 11 12 13
SC System
ID/ Name
from parent
CC-PRF
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Air Filter
Device Name
or
Description
of Area
Served
Air Filter Rack
Type
Design
Airflow Rate
for Air Filter
Device (cfm)
Air Filter
Nominal
Depth (inch)
Air Filter
Nominal
Length (inch)
Air Filter
Nominal
Width (inch)
Air Filter
Calculated
Nominal Face
Area (inch2)
Air Filter
Required
Minimum
Face Area
(inch2)
Face Area
Compliance
Design
Allowable
Pressure
Drop for Air
Filter Device
(inch W.C.)
HVAC1 living 1 living 1 Filter 1 Filter Grille 14000 3 20 30 600
Specified by
System
Designer
Specified by
System
Designer
1.0
HVAC1 LIVING 2 LIVING 2 Filter 2 Filter Grille 14000 3 20 30 600
Specified by
System
Designer
Specified by
System
Designer
1.0
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 6 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
L. Air Filter Device Requirements
01 All recirculated air and all outdoor air (including make up air) supplied to the occupiable space is filtered before passing through the system's thermal conditioning components.
02
The space conditioning system shall be designed to accommodate the clean-filter pressure drop imposed by the system air filter device(s). The design airflow rate and maximum
allowable clean-filter pressure drop at the design airflow rate applicable to each air filter shall be determined by the system designer. The system installer shall affix a sticker/label to
each system air filter grille/rack location that discloses the filter's design airflow rate and the filter's maximum allowable clean-filter pressure drop at the design airflow rate. The
sticker/labels shall be permanently affixed to the air filter grille/rack, readily legible, and visible to a person replacing the air filter.
03 All system air filter devices shall be located and installed in such a manner as to allow access and regular service by the system owner.
04
The system shall be provided with air filter media having a designated efficiency equal to or greater than MERV 13 when tested in accordance with ASHRAE Standard 52.2, or a particle
size efficiency rating equal to or greater than 50% in the 0.30 to 1.0 µm range and equal to or greater than 85 percent in the 1.0 - 3.0 µm range when tested in accordance with AHRI
Standard 680.
05 The system shall be provided with air filters that have been labeled by the manufacturer to disclose efficiency and pressure drop ratings that conform to the efficiency and pressure drop
requirements for the air filter grilles/racks..
06 Filter racks or grilles shall use gaskets, sealing, or other means to close gaps around inserted filters and prevent air from bypassing the filter.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met
M. HERS Verification Requirements For Duct Systems
01 02 03 04 05 06 07 08 09 10
SC System ID/
Name from
parent CC-PRF
SC System
Description of
Area Served
Indoor Unit Name
or Description of
Area Served
MCH-20
.
.
Duct Leakage Test
MCH-21
.
Duct Location
Verification
MCH-22
.
AHU Fan Efficacy
(W/cfm)
MCH-23
.
AHU Airflow Rate
(cfm/ton)
MCH-28
Return Duct
Design Table
150.0-B or C
MCH-29
Supply Duct
Surface Area
R-Value Buried
Ducts
MCH30
.
Central Fan
Ventilation
Cooling Credit
HVAC1 living 1 living 1 Yes No Yes Yes No No No
HVAC1 LIVING 2 LIVING 2 Yes No Yes Yes No No No
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 7 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
N. HERS Verification Requirements For Space Conditioning Equipment
01 02 03 04 05
SC System ID/ Name from parent CC-PRF SC System Description of Area Served
MCH-25
.
.
Refrigerant Charge
MCH-26
Rated SC System
Equipment Verification
MCH-33
VCHP Compliance Credit
HVAC1 living 1 Yes Yes No
HVAC1 LIVING 2 Yes Yes No
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 8 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
O. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures
Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly
installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations.
02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the
temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b).
03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)1 and
2).
04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature
rise specification. See Section 150.0(h)4.
05 Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d).
Cooling Equipment
06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations.
07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3,
and Section 150.0(m)9.
08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A.
09 Liquid Line Filter Drier: A liquid line filter drier shall be installed according to the manufacturer's specifications 150.0(h)3B
10 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)1 and 2.
Air Distribution System Ducts, Plenums and Fans
11 Insulation: The minimum duct insulation value is R-6 or ducts can be uninsulated if the duct system is located entirely in conditioned space. Note that higher values may be required by
the prescriptive or performance requirements. See Section 150.0(m)1B for exceptions.
12 Connections and Closures: All installed air-distribution system ducts and plenums must meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and
ANSI/SMACNA-006-2006:
Heat Pump Thermostat
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 9 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
O. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures
Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly
installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements.
13 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
14 The thermostat shall be installed in accordance with the manufacturers published installation specifications
15 First stage of heating shall be assigned to heat pump heating.
16 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEMS, DUCTS, AND FANS CF2R-MCH-01-E
(Page 10 of 10)
Registration Number: 424-P010143661A-000-002-M01009A-0000 Registration Date/Time: 2025-02-04 10:56:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:57:51
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this
statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all
applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the
enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made
available to the enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M27010A-0000
Registration Date/Time: 2025-02-04 10:57:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:32
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF2R-MCH-27-H
(Page 1 of 6)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard
62.2.-2019 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings subject to amendments specified by Title 24, Part 6
Section 150.0(o)1.
A. Whole-Dwelling Mechanical Ventilation - General Information
01 Dwelling unit name Single Family Dwelling
02 Building Type Single family attached
03 Project scope Newly Constructed
04
Total Conditioned Floor Area of Dwelling Unit
(For addition projects the conditioned floor area equals existing
area plus addition area. )
3066
05
Number of Bedrooms in Dwelling Unit
(For addition projects the number of bedrooms equals the existing
bedrooms plus addition bedrooms)
4
06 Ventilation System Type Balanced
07 Ventilation Operation Schedule Continuous
Note:
Non-dwelling units do not meet the definition for a dwelling unit as defined in Section 100.1(b). Non-dwelling units are not designed to provide
independent living facilities and do not provide permanent provisions for living, sleeping, eating, cooking and sanitation.
MCH-27a - Single Family Attached/Detached
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF2R-MCH-27-H
(Page 2 of 6)
Registration Number:
424-P010143661A-000-002-M27010A-0000
Registration Date/Time: 2025-02-04 10:57:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:32
B. Single Family Attached/Detached General Information
01 Average Ceiling Height 9.1
02 Total Conditioned Volume 27900.6
03 Vertical distance between the lowest and highest above grade
points within the pressure boundary in feet
9.1
04 Air Changes Per Hour at 50 Pa Default
05 Name of ANSI/ASHRAE Standard 62.2-2019 weather station for
climate zone
Palm Springs Intl
06 Weather and shielding factor (wsf) (Based on city identified above)0.45
C. Ventilation - Total Ventilation Rate
A mechanical supply system, exhaust system or combination thereof shall provide whole-dwelling ventilation with outdoor air each hour at no
less than the rate in 150.0(o)1Ci
01 Total Required Ventilation Rate (Qtot)129.48
02 Enclosure Leakage Rate (Q50)930.02
03 Effective Annual Average Infiltration Rate (Qinf 22.69
04 Total Exterior Envelope Surface Area 130
05 Unshared Exterior Envelope Surface Area (exclude surface areas
attached to garages or other dwelling units)
23
06 Required Mechanical Ventilation Rate (Qfan)125.47
D. Installed Ventilation - Total Ventilation Rate
A mechanical supply system, exhaust system, or combination thereof shall provide whole-dwelling ventilation with outdoor air
each hour at no less than the rate in 150.0(o)1Ci
01 02 03 04 05
Fan Name Fan Location Runtime (min/hr)Installed Mechanical
Ventilation Rate (CFM)
Equivalent Continuous
Ventilation (CFM)
NA ATTIC 60 150 150
06 Total Installed Continuous Ventilation (CFM)150
E. Compliance Statement
01 Building Passes Mechanical Ventilation RateTest
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF2R-MCH-27-H
(Page 3 of 6)
Registration Number:
424-P010143661A-000-002-M27010A-0000
Registration Date/Time: 2025-02-04 10:57:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:32
F. Other Requirements
The items listed below (6.1 through 6,6 abd 6.8 through 6.9) correspond to the information given in ASHRAE 62.2 Section 6 "Other
Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.8) for information describing these "Other
Requirements". The signature of the Responsible Person in the declaration statement below certifies that the dwelling complies with these
requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable.
01
6.1 Adjacent Spaces and Transfer Air.Measures shall be taken to minimize air movement across envelope components to dwelling units
from adjacent spaces such as garages, unconditioned crawl spaces, unconditioned attics and other dwelling. Supply and balanced
ventilation systems shall be designed and constructed to provide ventilation air directly from the outdoors.
6.1.1 Compliance for Attached Dwelling Units . One method of demonstrating compliance with Section 6.1 shall be to verify a leakage
rate below a maximum of 0.3 cfm per ft2 (150 L/s per 100 m2) of the dwelling unit envelope per area (i.e. the sum of the area of walls
between dwelling units, exterior walls, ceiling and floor) at a test pressure of 50 Pa by a blower door test conducted in accordance with
either ANSI/ASTME779 or ANSI/ASTM-E1827. The test shall be conducted with the dwelling unit as if it were exposed to outdoor air on all
sides, top and bottom by opening doors and windows of adjacent dwelling units.
02
6.2 Instructions and Labeling.Information on the ventilation design and/or ventilation systems installed, instructions on their proper
operation to meet the requirements of this standard, and instructions detailing any required maintenance (similar to that provided for
HVAC systems) shall be provided to the owner and the occupant of the dwelling unit. Controls shall be labeled as to their function (unless
that function is obvious, such as toilet exhaust fan switches). See Chapter 13 of Guideline 245 for information on instructions and labeling.
03 6.3 Clothes Dryers.Clothes dryers shall be exhausted directly to the outdoors. Exception: Condensing dryers plumbed to a drain.
04
6.4 Combustion and Solid-Fuel Burning Appliances.
6.4.1 Combustion and solid-fuel burning appliances must be provided with adequate combustion and ventilation air and vented in
accordance with manufacturer installation instructions, NFPA 31, NFPA 54/ ANSI Z223.1, NFPA 211, or other equivalent code acceptable
to the building official.
6.4.2 Where atmospherically vented combustion appliances or solid-fuel burning appliances are located inside the pressure boundary,
the total net exhaust flow of the two largest exhaust fans (not including a summer cooling fan intended to be operated only when
windows or other air inlets are open) shall not exceed 15 cfm/100 ft2 (75 L/s per 100 m2) of occupiable space when in operation at full
capacity. If the designed total net flow exceeds this limit, the net exhaust flow must be reduced by reducing the exhaust flow or providing
compensating outdoor airflow. Atmospherically vented combustion appliances do not include direct-vent appliances. Combustion
appliances that pass safety testing performed according to ANSI/BPI-1200 shall be deemed as complying with Section 6.4.2
05
6.5 Air Tightness Requirements
6.5.1 Garages.When an occupiable space adjoins a garage, the design must prevent migration of contaminants to the adjoining
occupiable space. Air seal the walls, ceilings, and floors that separate garages from occupiable space. To be considered air sealed, all
joints, seams, penetrations, openings between door assemblies and their respective jambs and framing, and other sources of air leakage
through wall and ceiling assemblies separating the garage from the residence and its attic area shall be caulked, gasketed, weather
stripped, wrapped, or otherwise sealed to limit air movement. Doors between garages and occupiable spaces shall be gasketed or made
substantially airtight with weather stripping.
06
6.6 Ventilation Opening Area.Spaces shall have ventilation openings as listed below. Such openings shall meet the requirements of
Section 6.8. Exception: Attached dwelling units and spaces that meet the local ventilation requirements set for bathrooms in Section 5 [of
ASHRAE 62.2].
6.6.1 Habitable Spaces.Each habitable space shall be provided with ventilation openings with an openable area not less than 4% of
the floor area or less than 5 ft2 (0.5 m2).
6.6.1 Toilets and Utility Rooms Toilets and utility rooms shall be provided with ventilation openings with an openable area not less
than 4% of the floor area or less than 1.5 ft2 (0.5 m2). Exceptions:
1.Utility rooms with a dryer exhaust duct.
2.Toilet compartments in bathrooms.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF2R-MCH-27-H
(Page 4 of 6)
Registration Number:
424-P010143661A-000-002-M27010A-0000
Registration Date/Time: 2025-02-04 10:57:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:32
F. Other Requirements
The items listed below (6.1 through 6,6 abd 6.8 through 6.9) correspond to the information given in ASHRAE 62.2 Section 6 "Other
Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.8) for information describing these "Other
Requirements". The signature of the Responsible Person in the declaration statement below certifies that the dwelling complies with these
requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable.
07
6.8 Air Inlets.Air inlets that are part of the ventilation design shall be located a minimum of 10 ft (3 m) from known sources of
contamination such as a stack, vent, exhaust hood, or vehicle exhaust. The intake shall be placed so that entering air is not obstructed by
snow, plantings, or other material. Forced air inlets shall be provided with rodent/insect screens (mesh not larger than 1/2 inch [13 mm]).
1.Ventilation openings in the wall may be as close as a stretched-string distance of 3 ft (1 m) from sources of contamination exiting
through the roof or dryer exhausts.
2.No minimum separation distance shall be required between windows and local exhaust outlets in kitchens and bathrooms.
3.Vent terminations covered by and meeting the requirements of the National Fuel Gas Code NFPA 54/ ANSI Z223.1)7 or equivalent.
4.Where a combined exhaust/intake termination is used to separate intake air from exhaust air originating in a living space other
than kitchens, no minimum separation distance between these two openings is required. For these combined terminations, the
exhaust air concentration within the intake air shall not exceed 10%, as established by the manufacturer.
08
6.9 Carbon Monoxide Alarms.A carbon monoxide alarm shall be installed in each dwelling unit in accordance with NFPA 720,Standard
for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 14, and shall be consistent with requirements of
applicable laws, codes, and standards.
09
Air Filter Efficiency.Supply only ventilation systems, makeup air-systems, and supply side balanced systems including HRV/ERV shall be
provided with air filters having a designated efficiency equal to or greater than MERV 13 when tested in accordance with ASHRAE
Standard 52.2, or a particle size efficiency rating equal to or greater than 50% in the 0.30-1.0 um range and equal to or greater than 85%
in the 1.0-3.0 um range when tested in accordance with AHRI Standard 680.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
G. Air Moving Equipment
The items listed below (7.1 through 7.4) correspond to the information given in ASHRAE 62.2 Section 7 "Air-Moving Equipment". Refer also to
Chapter 4.6 of the Residential Compliance Manual (Section 4.6.9) for information describing these requirements in more detail. The signature of
the Responsible Person in the declaration statement below certifies that the dwelling complies with these requirements specified in ASHRAE 62.2
Section 7.1 through 7.4 if applicable.
01
7.1 Selection and Installation.Ventilation devices and equipment shall be tested and listed in accordance with ANSI/ASHRAE Standard
51/ AMCA 210, and ANSI/AMCA Standard 300, and rated in accordance with the airflow and sound rating procedures of the Home
Ventilating Institute (HVI 915, 916, 920). Installations of systems or equipment shall be carried out in accordance with manufacturers'
design requirements and installation instructions.
02
7.2 Sound Ratings for Fans.Ventilation fans shall be rated for sound at no less than the minimum airflow rate required by this standard,
as noted below. These sound ratings shall be at a minimum of 0.1 in. w.c. (25 Pa) static pressure in accordance with the HVI procedure
referenced in 7.1.
Exception: HVAC air handlers and remote mounted fans need not meet sound requirements. To be considered for this exception, a
remote mounted fan must be mounted outside the habitable spaces, bathrooms, toilets, and hallways, and there must be at least 4 ft (1
m) of ductwork between the fan and the intake grille.
7.2.1 Dwelling Unit Ventilation or Continuous Local Exhaust Fans.These fans shall be rated for sound at a maximum of 1.0 sone.
7.2.2 Demand-Controlled Local Exhaust Fans.Bathroom exhaust fans used to comply with Section 5.2 shall be rated for sound at a
maximum of 3 sone, Kitchen exhaust fans used to comply with Section 5.2 shall be rated for sound at a maximum of 3 sone at one or
more airflow settings greater than or equal to 100 cfm (47 L/s).
Exceptions:
1.Fans with minimum airflow settings exceeding 400 cfm (189 L/s) need not comply.
2.Kitchen Range hoods may be rated for sound at the static pressure determined at working speed as specified in HVI 916 section 7.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF2R-MCH-27-H
(Page 5 of 6)
Registration Number:
424-P010143661A-000-002-M27010A-0000
Registration Date/Time: 2025-02-04 10:57:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:32
G. Air Moving Equipment
The items listed below (7.1 through 7.4) correspond to the information given in ASHRAE 62.2 Section 7 "Air-Moving Equipment". Refer also to
Chapter 4.6 of the Residential Compliance Manual (Section 4.6.9) for information describing these requirements in more detail. The signature of
the Responsible Person in the declaration statement below certifies that the dwelling complies with these requirements specified in ASHRAE 62.2
Section 7.1 through 7.4 if applicable.
03
7.3 Exhaust Ducts.
7.3.1 Multiple Exhaust Fans Using One Duct.Exhaust fans in separate dwelling units shall not share a common exhaust duct. If more
than one of the exhaust fans in a dwelling unit shares a common exhaust duct, each fan shall be equipped with a back draft damper to
prevent the recirculation of exhaust air from one room to another through the exhaust ducting system.
7.3.2 Single Exhaust Fan Ducted to Multiple Inlets.Where exhaust inlets are commonly ducted across multiple dwelling units, one or
more exhaust fans located downstream of the exhaust inlets shall be designed and intended to run continuously, or a system of one or
more backdraft dampers shall be installed to isolate each dwelling unit from the common duct when the fan is not running.
04
7.4 Supply Ducts.Where supply outlets are commonly ducted across multiple dwelling units, one or more supply fans located upstream
of the supply inlets shall be designed and intended to run continuously, or a system of one or more backdraft dampers shall be installed
to isolate each dwelling unit from the common duct when the fan is not running.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF2R-MCH-27-H
(Page 6 of 6)
Registration Number:
424-P010143661A-000-002-M27010A-0000
Registration Date/Time: 2025-02-04 10:57:26 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:32
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-M32022A-0000 Registration Date/Time: 2025-02-14 15:20:09 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:21:22
LOCAL MECHANICAL EXHAUST CF2R-MCH-32-H
(Page 1 of 5)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in
Residential Buildings, subject to the amendments specified in Section 150.0(o)1.
A. Local Mechanical Exhaust - General Information
01 Dwelling Unit Name Single Family Dwelling
02 Building Type Single family detached
03 Total Kitchen Floor Area 0
04 Kitchen Average Ceiling Height 0
05 Kitchen Total Conditioned Volume 0
06 Kitchen Type Non-Enclosed
07 Dwelling Unit Total Floor Area 3066
08 Kitchen Range (Cooking Stove) Fuel Type Electric
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
LOCAL MECHANICAL EXHAUST CF2R-MCH-32-H
(Page 2 of 5)
Registration Number: 424-P010143661A-000-002-M32022A-0000 Registration Date/Time: 2025-02-14 15:20:09 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:21:22
B. LOCAL MECHANICAL EXHAUST SYSTEM (SECTION 150.0(O)1G) - FAN SELECTION AND DUCT DESIGN CRITERIA FOR COMPLIANCE
Local mechanical exhaust fans shall be installed in each kitchen and bathroom in accordance with Section 150.0(o)1G. Systems shall be rated for airflow in accordance with
ASHRAE 62.2 section 7.1 Delivered local ventilation rates:
•All local ventilation rates have been measured using a flow hood, flow grid, or other airflow measuring device and meet the requirements of Tables 150.0-E, 150.0-F or
150.0-G OR
•The airflow rating at a pressure of 0.25 in w.c. of a certified fan is assumed because the local ventilation system duct sizing meets the prescriptive requirements of Table
150.0-H,
Table 150.0_E Demand-Controlled Local Ventialtion Exhaust Aiflow Rates and Capture Efficiency
Application AirFlow
Enclosed Kitchen or Nonenclosed
Kitchen
Vented range hood, including appliance-range hood combinations shall meet either the capture efficiency (CE) or the airflow rate specified in Table 150.0-G
as applicable.
Enclosed Kitchen Other kitchen exhaust fans, including downdraft: 300 cfm or a capacity of 5 ACH
Nonenclosed Kitchen Other kitchen exhaust fans, including downdraft: 300 cfm
Bathroom 50 cfm
Table 150.0_F Continuous Local Ventialtion Exhaust Aiflow Rates
Application AirFlow
Enclosed Kitchen 5 ach, based on kitchen volume.
Bathroom 20 cfm
Table 150.0_G Kitchen Range Hood Aiflow Rates (cfm) and ASTM E3087 Capture Efficiency(CE) Ratings According to Dwelling Unit Floor Area and Kitchen Range Fuel Type
Dwelling Unit Floor Area (ft2)Hood Over Electric Range Hood Over Natural Gas Range
>1500 50% CE or 110 cfm 70% CE or 180 cfm
>1000-1500 50% CE or 110 cfm 80% CE or 250 cfm
750-1000 55% CE or 130 cfm 85% CE or 280 cfm
<750 65% CE or 160 cfm 85% CE or 280 cfm
Table 150.0_H Prescriptive Ventialtion System Duct Sizing
Fan Airflow Rating, CFM at
minimum static pressure of 0.25 in.
water
≤50 (25)≤80 (40)≤100 (50)≤125 (60)≤150 (70)≤175 (85)≤200 (95)≤250 (120)≤350 (165)≤400 (190)≤450 (210)≤700 (330)≤800 (380)
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
LOCAL MECHANICAL EXHAUST CF2R-MCH-32-H
(Page 3 of 5)
Registration Number: 424-P010143661A-000-002-M32022A-0000 Registration Date/Time: 2025-02-14 15:20:09 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:21:22
Duct Type Minimum Duct Diameter, in. (mm)a,b
Rigid duct 4e(100)5 (125)5 (125)6 (150)6 (150)7 (180)7 (180)8 (205)9 (230)10 (255)10 (255)12 (305)12d(305)
Flex ductc 4 (100)5 (125)6 (150)6 (150)7 (180)7 (180)8 (205)8 (205)9 (230)10 (255)NP NP NP
a For noncircular ducts, calculate the diameter as four times the cross-sectional area divided by the perimeter.
b NP = application of the prescriptive table is not permitted for this scenario.
c Use of this table for verification of flex duct systems requires flex duct to be fully extended and any flex ductelbows to have a minimum bend radius to duct diameter ratio of 1.0.
d For this scenario, use of elbows is not permitted.
e For this scenario, 4 in. (100 mm) oval duct shall be permitted, provided the minor axis of the oval is greater than or equal to 3 in. (75 mm)
f When a vented range hood utilizes a capture efficiency rating to demonstrate compliance with 150.0(o)1Giiib, a static pressure greater than or equal to 0.25 in. of water at the rating point shall
not be required, and the airflow listed in the approved directory corresponding to the compliant capture efficiency rating point shall be applied to Table 150.0-H for determining compliance.
C. Kitchen Exhaust Systems
01 02 03 04 05 06 07 08 09 10 11 12 13
System
Name
Manufacturer
Name System Type
HVI or AHAM
Directory
Listed Model
Number
HVI or AHAM
Directory
Listed Rated
Airflow
HVI or AHAM
Directory
Listed Sound
Rating
Minimum
Airflow
(defaults to
rated
airflow)
Operation
Schedule
Method of
Compliance
Required
Minimum
Ventilation
Rate
Exception to
Maximum
Sound Rating
Compliance
Statement
for Airflow
Compliance
Statement
for Sound
Hood 1 GE Vented Range
Hood JVW5361SJSS 250 3.0 150 Demand
Control Airflow 110 3 sone Complies Complies
D. Continuous Kitchen Exhaust
01 Total Continuous Ventilation Airflow n/a
02 Required Minimum Continuous Ventilation Airflow n/a
03 Compliance Statement n/a
E. Other Requirements
01
Demand control exhaust system shall be provided with at least one of the following:
1.A readily accessible occupant-controlled on-off control.
2.An automatic control that does not impeded occupant on control.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
LOCAL MECHANICAL EXHAUST CF2R-MCH-32-H
(Page 4 of 5)
Registration Number: 424-P010143661A-000-002-M32022A-0000 Registration Date/Time: 2025-02-14 15:20:09 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:21:22
E. Other Requirements
02 Nonenclosed kitchens shall be provided with a demand-controlled mechanical exhaust system.
03 Each continuous mechanical exhaust system shall be provided with a readily accessible manual on-off control. (Multifamily dwellings are exempt from readily accessible requirement. )
04 Continuous mechanical exhaust systems shall be designed to operate during all occupiable hours.
05
Exhaust fans in separate dwelling units shall not share a common exhaust duct. Exhaust inlets from more than one dwelling unit may be served by a single exhaust fan downstream of all
the exhaust inlets if the fan is designated and intended to run continuously or if each inlet is equipped with a back-draft damper to prevent cross-contamination when the fan is not
running.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
LOCAL MECHANICAL EXHAUST CF2R-MCH-32-H
(Page 5 of 5)
Registration Number: 424-P010143661A-000-002-M32022A-0000 Registration Date/Time: 2025-02-14 15:20:09 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:21:22
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Signature Date:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable classification to accept responsibility for the system design,
construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this certificate of installation conforms to all applicable codes and
regulations and the installation conforms to the requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary
corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building permit(s) issued for the building and made available to the
enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation the builder provides to the building owner at occupancy, and I
will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
Raymond Weden (authorized Steven Bryant)
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Richmond American Homes of California Inc - SoCal
Position With Company (Title):
Director of Purchasing
Address:
5171 California Ave, Suite 120
CSLB License:
487535
City/State/Zip:
Irvine CA 92617
Phone:
949-467-2261
Date Signed:
2025-02-14
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M20011A-0000
Registration Date/Time: 2025-02-04 10:57:41 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:47
DUCT LEAKAGE DIAGNOSTIC TEST CF2R-MCH-20-H
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served living 1
03 Indoor Unit Name or Description of Area Served living 1
04 Building Type from parent CC Single family
05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit
from parent CC?
No, credit is not taken
06 Verified Low Leakage Air Handling Unit Credit from parent CC?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be
used
07 Duct System Compliance Category New
08 Portions of Duct Located in Garage?No
09 Is the system type Small Duct High Velocity (SDHV) ?No
MCH-20c - Low Leakage Air-Handling Unit (LLAHU)
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF2R-MCH-20-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M20011A-0000
Registration Date/Time: 2025-02-04 10:57:41 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:47
B. Duct Leakage Diagnostic Test
01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method
02 Condenser Nominal Cooling Capacity (ton)5
03 Indoor Unit Nominal Cooling Capacity n/a
04 Heating Capacity (kBtu/h)n/a
05 Conditioned Floor Area Served by this HVAC System (ft2)3066
06 Measured AHU Airflow (cfm)n/a
07 Duct Leakage Test Conditions Test final
08 Duct Leakage Test Method Total leakage
09 Leakage Factor 0.05
10 Calculated Target Allowable Duct Leakage (cfm)100
11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm).6
12 Air Handling Unit Manufacturer Name GOODMAN
13 Air Handling Unit Model Number GM9S960805
14 Compliance Statement System passes leakage test
C. Additional Requirements for Compliance
01
The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low
Leakage Air-Handling Units published on the Energy Commission Website at:
http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf
02 System was tested in its normal operation condition. No temporary taping allowed.
03
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation
Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closed position during duct leakage testing.
04 All supply and return register boots were sealed to the drywall.
05 Building cavities were not used as plenums or platform returns in lieu of ducts.
06 If cloth backed tape was used it was covered with Mastic and draw bands.
07 All connection points between the air handler and the supply and return plenums are completely sealed.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have
been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF2R-MCH-20-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M20011A-0000
Registration Date/Time: 2025-02-04 10:57:41 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:58:47
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M23012A-0000
Registration Date/Time: 2025-02-04 10:57:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:00
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF2R-MCH-23-H
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served living 1
03 Indoor Unit Name living 1
04 System Installation Type New
05 Nominal Cooling Capacity (tons)5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum.
Procedures for installing HSPP or PSPP are specified in RA3.3.1.1.
01 Method Used to Demonstrate Compliance with the HSPP/PSPP
Requirement
HSPP installed and labeled consistent with Figure RA3.3-1
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF2R-MCH-23-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M23012A-0000
Registration Date/Time: 2025-02-04 10:57:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:00
C. Airflow Rate Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2.
01 Airflow Rate Measurement Type used for this airflow rate
verification.
Traditional Flow Capture Hood according to procedure in
RA3.3.3.1.4
02 Manufacturer of Airflow Measurement Apparatus Shortridge
03 Model number of Airflow Measurement Apparatus 8401
04
Certification Status of the Airflow Measurement Apparatus
Accuracy
Certified by Manufacturer and listed on CEC Website at
http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index.
html
MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
D. Forced Air System Airflow Rate Measurement
The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3.
01 Required Minimum System Airflow Rate (cfm/ton)350
02 Required Minimum System Airflow Target (cfm)1750
03 Actual System Airflow Rate Measurement (cfm)1750
04 Compliance Statement:System airflow rate complies
E. Additional Requirements
01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system
during system air flow rate measurement identified on this Certificate of Installation.
02
The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was
calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in
RA3.3.1.
03
A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return
duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an
allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate
shall conform to the specifications listed on the Certificate of Compliance.
04 All registers were fully open during the diagnostic test.
05 System fan was set at maximum speed during the diagnostic test.
06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF2R-MCH-23-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M23012A-0000
Registration Date/Time: 2025-02-04 10:57:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:00
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M22013A-0000
Registration Date/Time: 2025-02-04 10:58:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:16
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF2R-MCH-22-H
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 System Identification or Name HVAC1
02 System Location or Area Served living 1
03 Indoor Unit Name or Description of Area Served living 1
04 System Installation Type New
05 Nominal Cooling Capacity (tons) of Condenser 5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Fan Watt Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2.
01 Fan Watt Verification Device Used.Digital Utility Revenue Meter
MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF2R-MCH-22-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M22013A-0000
Registration Date/Time: 2025-02-04 10:58:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:16
C. Forced Air System Fan Efficacy Measurement
The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3
01 Actual Tested Watts .6
02 Actual Tested Airflow from MCH-23 (cfm)1750
03 Required Fan Efficacy (Watts/cfm)0.45
04 Actual Fan Efficacy (Watts/cfm)0
05 Compliance Statement:System fan efficacy complies
D. Additional Requirements
01 All registers were fully open during the diagnostic test.
02 System fan was set at maximum speed during the diagnostic test.
03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm)
criteria in every zonal control mode.
07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data
acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF2R-MCH-22-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M22013A-0000
Registration Date/Time: 2025-02-04 10:58:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:16
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M25017A-0000
Registration Date/Time: 2025-02-04 10:59:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:00:16
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 1 of 5)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
Each system requiring refrigerant charge verification will be documented on a separate certificate.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served living 1
03 Condenser (or package unit) Make or Brand GOODMAN
04 Condenser (or package unit) Model Number GSXH506010
05 Nominal Cooling Capacity (tons) of Condenser 5
06 Condenser (or package unit) Serial Number NA
07 Refrigerant Type R-410A
08 Other Refrigerant Type (if applicable)n/a
09 Liquid Line Filter Drier Installed According to Manufacturers
Specifications (if applicable)
Yes
10 System Installation Type New
11 Fault Indicator Display (FID) Status (Note: Even systems with a FID
must have refrigerant charge verified by installer).
This system does not have a FID device installed
12
Is the system of a type that the minimum airflow can be verified for
all indoor units using an approved measurement procedure (RA3.3
or RA3.3.3)?
Yes
13
Is the system of a type that approved refrigerant charge verification
procedures can be used to verify compliance with the refrigerant
charge verification requirements when temperatures are >= 55 °F
(RA3.2.2, or RA1)?
Yes, one of the Refrigerant charge verification procedures from
RA3.2.2 or RA1 is applicable to this system and can be used to
verify compliance
14 Date of Refrigerant Charge Verification for this system 2025-02-04
15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than
55 degF)
16 Person who performed the Refrigerant Charge Verification
reported on this Certificate of Installation
HVAC system installer
17 HERS Verification Compliance Requirement Status System qualifies for group sampling
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 2 of 5)
Registration Number:
424-P010143661A-000-002-M25017A-0000
Registration Date/Time: 2025-02-04 10:59:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:00:16
MCH-25b - Refrigerant Charge Verification - Subcooling Method
B. Metering Device Verification
Subcooling Method can only be used on systems that have a variable metering device.
01 Refrigerant metering device Thermostatic Expansion Valve (TXV)
02 Subcooling Method applicability status Subcooling Method is applicable to this system.
C. Instrument Calibration
Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2
01 Date of Digital Refrigerant Gauge Calibration 2025-01-13
02 Date of Digital Thermocouple Calibration 2025-01-13
03 Digital Refrigerant Gauge Calibration Status Calibration is current
04 Digital Thermocouple Calibration Status Calibration is current
D. Measurement Access Hole (MAH) Verification
Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3
01 Method Used to Demonstrate Compliance with the Measurement
Access Hole (MAH) Requirement
MAH installed and labeled consistent with Figure 3.2-1
E. Minimum System Airflow Rate Verification
Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3.
01 02 03
Indoor Unit Name or Description of Area
Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status
living 1 1750 System complies with minimum airflow rate
requirements
04 SC System complies with Minimum System Airflow Rate Verification
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 3 of 5)
Registration Number:
424-P010143661A-000-002-M25017A-0000
Registration Date/Time: 2025-02-04 10:59:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:00:16
F. Data Collection and Calculations
Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix
RA3.2.2.
01 Lowest Return Air Dry Bulb Temperature that Occurred During the
Refrigerant Charge Verification Procedure ( °F)
95
02 Measured Condenser Air Entering Dry-Bulb Temperature
(Tcondenser, db)
94
03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling
refrigerant charge verification method
04 Measured Liquid Line Temperature (Tliquid) ( °F)85
05 Measured Liquid Line Pressure (Pliquid) (psig)100
06 Condenser Saturation Temperature (Tcondenser, sat) from Digital
Gauge or P-T Table using Line F05 ( °F)
95
07 Measured Subcooling (Line F06 - Lilne F04 ( °F)10
08 Target Subcooling from Manufacturer ( °F)10
09 Compliance Statement:System complies with Subcooling Method - Must also pass
metering device verification, next section
G. Metering Device Verification
Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2
01 Measured Suction Line Temperature (Tsuction) ( °F)55
02 Measured Suction Line Pressure (Psuction) (psig)85
03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital
Gauge or P-T Table using Line G02 ( °F)
45
04 Measured Superheat (Line G01- Line G03) ( °F)10
05 Measured Superheat (Line G04) is between 4 °F and 25 °F
(inclusive)
Passes CEC requirement
06 Measured Superheat (Line G04) is within Manufacturer's
Specifications ( if known)
Yes, documentation to be provided upon request
07 Compliance Statement Metering device verification passes
MCH-25d - Refrigeration Charge Verification - Fault Indicator Display (FID)
H. Fault Indicator Display
This section does not apply to this project.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 4 of 5)
Registration Number:
424-P010143661A-000-002-M25017A-0000
Registration Date/Time: 2025-02-04 10:59:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:00:16
I. Fault Indicator Display Additional Requirements
This section does not apply to this project.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 5 of 5)
Registration Number:
424-P010143661A-000-002-M25017A-0000
Registration Date/Time: 2025-02-04 10:59:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:00:16
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M26018A-0000
Registration Date/Time: 2025-02-04 11:02:42 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:03:48
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 1 of 4)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
Procedures for verification of High SEER/SEER2 and EER/EER2 Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring
verification must use a separate form.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served living 1
03 Efficiency Metric EER2/SEER2
04 Status: SEER/SEER2 Performance Compliance Credit Check Yes
05 Status: EER/EER2 Performance Compliance Credit Check Yes
06 Status: Heat Pump Heating Output Performance Compliance Check No
07 Status: HSPF/HSPF2 Performance Compliance Credit Check No
08 Directory used to certify product performance AHRI
09 AHRI certification number for the installed space conditioning
system from http://www.ahridirectory.org
214287336
10 Does the directory used to certify product performance require a
specific air handler, furnace or fan coil make and model?
Furnace air-handling unit
11 Does the directory used to certify product performance require a
time delay relay (+TDR)?
Yes
12 Does the directory used to certify product performance require a
TXV (+TXV)?
Yes
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-M26018A-0000
Registration Date/Time: 2025-02-04 11:02:42 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:03:48
B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System
The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used
to certify product performance in order to demonstrate compliance.
01 02 03 04
Data from nameplate of installed system component
05 06 07 08 09 10
SC System
ID/Name
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 living 1 living 1 AC Coil GOODMAN GSXH50601
0 GOODMAN CP61C34 GOODMAN GM9S96080
5
C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance
The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used
to certify product performance in order to demonstrate compliance.
01 02 03 04
Data from the Directory used to certify product performance for the rated system
component
05 06 07 08 09 10
SC System
ID/Name
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 living 1 living 1 AC Coil GOODMAN GSXH50601
0 GOODMAN CP61C34 GOODMAN GM9S96080
5
D. Verified Cooling System SEER/SEER2
01 Required minimum SEER/SEER2 15.2
02 Installed SEER/SEER2 15.2
03 Compliance Statement:System passes SEER/SEER2 verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent Certificate of Compliance.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-M26018A-0000
Registration Date/Time: 2025-02-04 11:02:42 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:03:48
E. Verified Cooling System EER/EER2
01 Required minimum EER/EER2 12.5
02 Installed EER/EER2 12.5
03 Compliance Statement:System passes EER/EER2 verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent Certificate of Compliance.
F. Verified Heat Pump Heating Output
This section does not apply to this project.
G. Verified Heat Pump HSPF/HSPF2
This section does not apply to this project.
H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil
01
If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person
certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of
Certified Product Performance.
I. Verified Space Conditioning System Time Delay Relay
01
If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this
compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of
RA3.4.3.
J. Verified Space Conditioning System TXV
01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance
document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-M26018A-0000
Registration Date/Time: 2025-02-04 11:02:42 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:03:48
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M20014A-0000
Registration Date/Time: 2025-02-04 10:58:20 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:26
DUCT LEAKAGE DIAGNOSTIC TEST CF2R-MCH-20-H
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served LIVING 2
03 Indoor Unit Name or Description of Area Served LIVING 2
04 Building Type from parent CC Single family
05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit
from parent CC?
No, credit is not taken
06 Verified Low Leakage Air Handling Unit Credit from parent CC?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be
used
07 Duct System Compliance Category New
08 Portions of Duct Located in Garage?No
09 Is the system type Small Duct High Velocity (SDHV) ?No
MCH-20c - Low Leakage Air-Handling Unit (LLAHU)
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF2R-MCH-20-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M20014A-0000
Registration Date/Time: 2025-02-04 10:58:20 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:26
B. Duct Leakage Diagnostic Test
01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method
02 Condenser Nominal Cooling Capacity (ton)5
03 Indoor Unit Nominal Cooling Capacity n/a
04 Heating Capacity (kBtu/h)n/a
05 Conditioned Floor Area Served by this HVAC System (ft2)0
06 Measured AHU Airflow (cfm)n/a
07 Duct Leakage Test Conditions Test final
08 Duct Leakage Test Method Total leakage
09 Leakage Factor 0.05
10 Calculated Target Allowable Duct Leakage (cfm)100
11 Actual Duct Leakage Rate from Leakage Test Measurement (cfm).6
12 Air Handling Unit Manufacturer Name GOODMAN
13 Air Handling Unit Model Number GM9S960603
14 Compliance Statement System passes leakage test
C. Additional Requirements for Compliance
01
The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low
Leakage Air-Handling Units published on the Energy Commission Website at:
http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf
02 System was tested in its normal operation condition. No temporary taping allowed.
03
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation
Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closed position during duct leakage testing.
04 All supply and return register boots were sealed to the drywall.
05 Building cavities were not used as plenums or platform returns in lieu of ducts.
06 If cloth backed tape was used it was covered with Mastic and draw bands.
07 All connection points between the air handler and the supply and return plenums are completely sealed.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have
been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF2R-MCH-20-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M20014A-0000
Registration Date/Time: 2025-02-04 10:58:20 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:26
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M23015A-0000
Registration Date/Time: 2025-02-04 10:58:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:42
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF2R-MCH-23-H
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served LIVING 2
03 Indoor Unit Name LIVING 2
04 System Installation Type New
05 Nominal Cooling Capacity (tons)2.5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum.
Procedures for installing HSPP or PSPP are specified in RA3.3.1.1.
01 Method Used to Demonstrate Compliance with the HSPP/PSPP
Requirement
HSPP installed and labeled consistent with Figure RA3.3-1
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF2R-MCH-23-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M23015A-0000
Registration Date/Time: 2025-02-04 10:58:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:42
C. Airflow Rate Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2.
01 Airflow Rate Measurement Type used for this airflow rate
verification.
Traditional Flow Capture Hood according to procedure in
RA3.3.3.1.4
02 Manufacturer of Airflow Measurement Apparatus Shortridge
03 Model number of Airflow Measurement Apparatus 8401
04
Certification Status of the Airflow Measurement Apparatus
Accuracy
Certified by Manufacturer and listed on CEC Website at
http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index.
html
MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
D. Forced Air System Airflow Rate Measurement
The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3.
01 Required Minimum System Airflow Rate (cfm/ton)350
02 Required Minimum System Airflow Target (cfm)875
03 Actual System Airflow Rate Measurement (cfm)875
04 Compliance Statement:System airflow rate complies
E. Additional Requirements
01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system
during system air flow rate measurement identified on this Certificate of Installation.
02
The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was
calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in
RA3.3.1.
03
A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return
duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an
allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate
shall conform to the specifications listed on the Certificate of Compliance.
04 All registers were fully open during the diagnostic test.
05 System fan was set at maximum speed during the diagnostic test.
06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF2R-MCH-23-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M23015A-0000
Registration Date/Time: 2025-02-04 10:58:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:42
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M22016A-0000
Registration Date/Time: 2025-02-04 10:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:55
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF2R-MCH-22-H
(Page 1 of 3)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 System Identification or Name HVAC1
02 System Location or Area Served LIVING 2
03 Indoor Unit Name or Description of Area Served LIVING 2
04 System Installation Type New
05 Nominal Cooling Capacity (tons) of Condenser 2.5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Fan Watt Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2.
01 Fan Watt Verification Device Used.Digital Utility Revenue Meter
MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF2R-MCH-22-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M22016A-0000
Registration Date/Time: 2025-02-04 10:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:55
C. Forced Air System Fan Efficacy Measurement
The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3
01 Actual Tested Watts .6
02 Actual Tested Airflow from MCH-23 (cfm)875
03 Required Fan Efficacy (Watts/cfm)0.45
04 Actual Fan Efficacy (Watts/cfm)0
05 Compliance Statement:System fan efficacy complies
D. Additional Requirements
01 All registers were fully open during the diagnostic test.
02 System fan was set at maximum speed during the diagnostic test.
03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm)
criteria in every zonal control mode.
07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data
acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF2R-MCH-22-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M22016A-0000
Registration Date/Time: 2025-02-04 10:58:49 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 10:59:55
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M25019A-0000
Registration Date/Time: 2025-02-04 11:04:23 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:05:29
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 1 of 5)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
Each system requiring refrigerant charge verification will be documented on a separate certificate.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served LIVING 2
03 Condenser (or package unit) Make or Brand GOODMAN
04 Condenser (or package unit) Model Number GSXH503010
05 Nominal Cooling Capacity (tons) of Condenser 2.5
06 Condenser (or package unit) Serial Number NA
07 Refrigerant Type R-410A
08 Other Refrigerant Type (if applicable)n/a
09 Liquid Line Filter Drier Installed According to Manufacturers
Specifications (if applicable)
Yes
10 System Installation Type New
11 Fault Indicator Display (FID) Status (Note: Even systems with a FID
must have refrigerant charge verified by installer).
This system does not have a FID device installed
12
Is the system of a type that the minimum airflow can be verified for
all indoor units using an approved measurement procedure (RA3.3
or RA3.3.3)?
Yes
13
Is the system of a type that approved refrigerant charge verification
procedures can be used to verify compliance with the refrigerant
charge verification requirements when temperatures are >= 55 °F
(RA3.2.2, or RA1)?
Yes, one of the Refrigerant charge verification procedures from
RA3.2.2 or RA1 is applicable to this system and can be used to
verify compliance
14 Date of Refrigerant Charge Verification for this system 2025-02-04
15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than
55 degF)
16 Person who performed the Refrigerant Charge Verification
reported on this Certificate of Installation
HVAC system installer
17 HERS Verification Compliance Requirement Status System qualifies for group sampling
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 2 of 5)
Registration Number:
424-P010143661A-000-002-M25019A-0000
Registration Date/Time: 2025-02-04 11:04:23 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:05:29
MCH-25b - Refrigerant Charge Verification - Subcooling Method
B. Metering Device Verification
Subcooling Method can only be used on systems that have a variable metering device.
01 Refrigerant metering device Thermostatic Expansion Valve (TXV)
02 Subcooling Method applicability status Subcooling Method is applicable to this system.
C. Instrument Calibration
Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2
01 Date of Digital Refrigerant Gauge Calibration 2025-01-13
02 Date of Digital Thermocouple Calibration 2025-01-13
03 Digital Refrigerant Gauge Calibration Status Calibration is current
04 Digital Thermocouple Calibration Status Calibration is current
D. Measurement Access Hole (MAH) Verification
Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3
01 Method Used to Demonstrate Compliance with the Measurement
Access Hole (MAH) Requirement
MAH installed and labeled consistent with Figure 3.2-1
E. Minimum System Airflow Rate Verification
Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3.
01 02 03
Indoor Unit Name or Description of Area
Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status
LIVING 2 1750 System complies with minimum airflow rate
requirements
04 SC System complies with Minimum System Airflow Rate Verification
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 3 of 5)
Registration Number:
424-P010143661A-000-002-M25019A-0000
Registration Date/Time: 2025-02-04 11:04:23 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:05:29
F. Data Collection and Calculations
Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix
RA3.2.2.
01 Lowest Return Air Dry Bulb Temperature that Occurred During the
Refrigerant Charge Verification Procedure ( °F)
95
02 Measured Condenser Air Entering Dry-Bulb Temperature
(Tcondenser, db)
94
03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling
refrigerant charge verification method
04 Measured Liquid Line Temperature (Tliquid) ( °F)85
05 Measured Liquid Line Pressure (Pliquid) (psig)100
06 Condenser Saturation Temperature (Tcondenser, sat) from Digital
Gauge or P-T Table using Line F05 ( °F)
95
07 Measured Subcooling (Line F06 - Lilne F04 ( °F)10
08 Target Subcooling from Manufacturer ( °F)10
09 Compliance Statement:System complies with Subcooling Method - Must also pass
metering device verification, next section
G. Metering Device Verification
Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2
01 Measured Suction Line Temperature (Tsuction) ( °F)55
02 Measured Suction Line Pressure (Psuction) (psig)85
03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital
Gauge or P-T Table using Line G02 ( °F)
45
04 Measured Superheat (Line G01- Line G03) ( °F)10
05 Measured Superheat (Line G04) is between 4 °F and 25 °F
(inclusive)
Passes CEC requirement
06 Measured Superheat (Line G04) is within Manufacturer's
Specifications ( if known)
Yes, documentation to be provided upon request
07 Compliance Statement Metering device verification passes
MCH-25d - Refrigeration Charge Verification - Fault Indicator Display (FID)
H. Fault Indicator Display
This section does not apply to this project.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 4 of 5)
Registration Number:
424-P010143661A-000-002-M25019A-0000
Registration Date/Time: 2025-02-04 11:04:23 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:05:29
I. Fault Indicator Display Additional Requirements
This section does not apply to this project.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF2R-MCH-25-H
(Page 5 of 5)
Registration Number:
424-P010143661A-000-002-M25019A-0000
Registration Date/Time: 2025-02-04 11:04:23 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:05:29
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M26020A-0000
Registration Date/Time: 2025-02-04 11:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:06:00
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 1 of 4)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
Procedures for verification of High SEER/SEER2 and EER/EER2 Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring
verification must use a separate form.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served LIVING 2
03 Efficiency Metric EER2/SEER2
04 Status: SEER/SEER2 Performance Compliance Credit Check Yes
05 Status: EER/EER2 Performance Compliance Credit Check Yes
06 Status: Heat Pump Heating Output Performance Compliance Check No
07 Status: HSPF/HSPF2 Performance Compliance Credit Check No
08 Directory used to certify product performance AHRI
09 AHRI certification number for the installed space conditioning
system from http://www.ahridirectory.org
21486805
10 Does the directory used to certify product performance require a
specific air handler, furnace or fan coil make and model?
Furnace air-handling unit
11 Does the directory used to certify product performance require a
time delay relay (+TDR)?
Yes
12 Does the directory used to certify product performance require a
TXV (+TXV)?
Yes
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-M26020A-0000
Registration Date/Time: 2025-02-04 11:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:06:00
B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System
The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used
to certify product performance in order to demonstrate compliance.
01 02 03 04
Data from nameplate of installed system component
05 06 07 08 09 10
SC System
ID/Name
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 LIVING 2 LIVING 2 AC Coil GOODMAN GSXH50301
0 GOODMAN CP37E34 GOODMAN GM9S96060
3
C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance
The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used
to certify product performance in order to demonstrate compliance.
01 02 03 04
Data from the Directory used to certify product performance for the rated system
component
05 06 07 08 09 10
SC System
ID/Name
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 LIVING 2 LIVING 2 AC Coil GOODMAN GSXH50601
0 GOODMAN CP61C34 GOODMAN GM9S96080
5
D. Verified Cooling System SEER/SEER2
01 Required minimum SEER/SEER2 15.2
02 Installed SEER/SEER2 15.2
03 Compliance Statement:System passes SEER/SEER2 verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent Certificate of Compliance.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-M26020A-0000
Registration Date/Time: 2025-02-04 11:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:06:00
E. Verified Cooling System EER/EER2
01 Required minimum EER/EER2 12.5
02 Installed EER/EER2 12.5
03 Compliance Statement:System passes EER/EER2 verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent Certificate of Compliance.
F. Verified Heat Pump Heating Output
This section does not apply to this project.
G. Verified Heat Pump HSPF/HSPF2
This section does not apply to this project.
H. Verified Space Conditioning System Air Handler, Furnace Or Fan Coil
01
If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person
certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of
Certified Product Performance.
I. Verified Space Conditioning System Time Delay Relay
01
If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this
compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of
RA3.4.3.
J. Verified Space Conditioning System TXV
01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance
document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF2R-MCH-26-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-M26020A-0000
Registration Date/Time: 2025-02-04 11:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-04 11:06:00
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2025-02-04
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this certificate of installation is true and correct.
2.I am either: a) a responsible person eligible under division 3 of the business and professions code in the applicable
classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this certificate of installation, and attest to the
declarations in this statement, or b) i am an authorized representative of the responsible person and attest to the
declarations in this statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on
this certificate of installation conforms to all applicable codes and regulations and the installation conforms to the
requirements given on the certificate of compliance, plans, and specifications approved by the enforcement agency.
4.I understand that a HERS rater will check the installation to verify compliance and if such checking determines the
installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner.
5.I understand that a registered copy of this certificate of installation shall be posted or made available with the building
permit(s) issued for the building and made available to the enforcement agency for all applicable inspections, and I will
take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this certificate of installation is required to be included with the documentation
the builder provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is
accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or
Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2025-02-04
Third Party Quality Control Program (TPQCP) Status:Name of TPQCP (if applicable):
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-B02001A-0000 Registration Date/Time: 2024-11-07 14:19:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2024-11-07 14:20:51
SINGLE DWELLING UNIT HOT WATER SYSTEM DISTRIBUTION CF2R-PLB-02-E
(Page 1 of 4)
CERTIFICATE OF INSTALLATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A2. Design Dwelling Unit HPWH System Information
This table reports features of HPWH water heating system(s) that were specified on the registered CF1R compliance document for this project.
01 02 03 04 05 06 07 08
Dwelling Unit Name Water Heating System ID
or Name
Modeled Equipment
Make and Model
# of Like (or Identical)
Water Heaters in System Tank Location Exterior Tank Insulation
R-Value
Dwelling Unit DHW
System Distribution Type Compact Distribution
Single Family Dwelling DHW Sys 1 RheemPROPH65T2RH375
30 1 TankZone N/A StandardDistribution NotCompact
B2. Installed Dwelling Unit HPWH System Information
This table reports the water heating systems(s) installed in this project.
01 02 03 04 05 06 07 08 09
Dwelling Unit Name Water Heating System
ID or Name Make and Model
# of Like (or Identical)
Water Heaters in
System
Tank Location Exterior Tank
Insulation R-Value Tank Volume
Dwelling Unit DHW
System Distribution
Type
Compact Distribution
Single Family Dwelling DHW Sys 1 RheemPROPH65T2RH3
7530 1 Tank Zone Standard Distribution
System None
C. Design Dwelling Unit Water Heating Efficiency Information
This table reports the water heater(s) efficiency features specified on the registered CF1R compliance document for this project.
01 02 03 04 05 06 07
Water Heating System
ID or Name Heating Efficiency Type Heating Efficiency
Value Standby Loss (%)Exterior Insul. R-Value Water Heater Storage
Volume (gal)Tank Location
DHW Sys 1 65.00 Tank Zone
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SINGLE DWELLING UNIT HOT WATER SYSTEM DISTRIBUTION CF2R-PLB-02-E
(Page 2 of 4)
Registration Number: 424-P010143661A-000-002-B02001A-0000 Registration Date/Time: 2024-11-07 14:19:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2024-11-07 14:20:51
D. Installed Dwelling Unit Water Heating Efficiency Information
This table reports the water heating system features that were installed in this project.
01 02 03 04 05 06 07
Water Heating System
ID or Name Heating Efficiency Type Heating Efficiency
Value Standby Loss (%)Exterior Insul. R-Value Water Heater Storage
Volume (gal)Tank Location
DHW Sys 1 65 Tank Zone
E. Installed Water Heater Manufacturer Information
01 02 03
Water Heating System ID or Name Manufacturer Model Number
DHW Sys 1 Rheem Rheem RTGH-84DVN condensing tankless w/h
F. Mandatory Measures for all Domestic Hot Water Distribution Systems
01 Equipment shall meet the applicable requirements of the Appliance Efficiency Regulations (Section 110.3(b)1).
02 Unfired storage tanks are insulated with an external R-3.5 or combination of R-16 internal and external Insulation. (Section 110.3(c)4).
03
All domestic hot water pipes shall be insulated as specified in Section 609.11 of the California Plumbing Code.
•Insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve.
•Piping that penetrates framing members shall not be required to have pipe insulation for the distance of the framing penetration.
•Piping that penetrates metal framing shall use grommets, plugs, wrapping or other insulating material to assure that no contact is made with the metal framing. Insulation shall
butt securely against all framing members.
•Piping installed in interior or exterior walls that is surrounded on all sides by at least 1 inch (2.5 cm) of insulation.
•Piping installed in crawl space with a minimum of 1 inch (2.5 cm) of crawl space insulation above and below.
•Piping installed in attics with a minimum of 4 inches (10 cm) of attic insulation on top
•Piping insulation shall fit tightly, and all elbows and tees shall be fully insulated.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SINGLE DWELLING UNIT HOT WATER SYSTEM DISTRIBUTION CF2R-PLB-02-E
(Page 3 of 4)
Registration Number: 424-P010143661A-000-002-B02001A-0000 Registration Date/Time: 2024-11-07 14:19:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2024-11-07 14:20:51
F. Mandatory Measures for all Domestic Hot Water Distribution Systems
04
For Gas or Propane Water Heaters: Ensure either a or b are installed (Section 150.0(n))
a) A designated space at least 2.5 feet by 2.5 feet and 7 feet tall within 3 feet from the water heater
1.A dedicated 120V, 20A electrical receptacle connected to the electrical panel with a 120/240V 3 conductor, 10AWG copper branch circuit, within 3 feet from the water heater
and accessible with no obstructions
2.The conductor shall be labeled with the word "Spare" on both ends; and
3.A reserved single pole circuit breaker space next to the circuit breaker next to the branch circuit labeled "Future" 240V shall be provided.
4.A condensate drain no more than 2 inches higher than the base on water heater for natural draining
b) A designated space at least 2.5 feet by 2.5 feet and 7 feet tall within 3 feet from the water heater
1.A dedicated 240 volt branch circuit shall be installed within 3 feet from the designated space. The branch circuit shall be rated at 30 amps minimum. The blank cover shall be
identified as "240V ready"; and
2.The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future HPWH installation. The reserved space shall
be permanently marked as "For Future 240V use"; and
3.Either a dedicated cold water supply, or the cold water supply shall pass through the designated HPWH location just before reaching the gas or propane water heater; and
4.The hot water supply pipe coming out of the gas or propane water heater shall be routed first through the designated HPWH location before serving any fixtures; and
5.The hot and cold water piping at the designated HPWH location shall be exposed and readily accessible for future installation of a HPWH; and
6.A condensate drain no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
SINGLE DWELLING UNIT HOT WATER SYSTEM DISTRIBUTION CF2R-PLB-02-E
(Page 4 of 4)
Registration Number: 424-P010143661A-000-002-B02001A-0000 Registration Date/Time: 2024-11-07 14:19:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2024-11-07 14:20:51
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Kim Schmitz
Documentation Author Signature:
Company:
NP Mechanical, Inc.
Signature Date:
2024-11-07
Address:
P.O. Box 309
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Installation is true and correct.
2.II am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the
system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of
Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this
statement on the responsible person’s behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all
applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the
enforcement agency.
4.I understand that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made
available to the enforcement agency for all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
5.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
Responsible Builder/Installer Name:
Kim Schmitz
Responsible Builder/Installer Signature:
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
NP Mechanical, Inc.
Position With Company (Title):
Contractor/Installer
Address:
P.O. Box 309
CSLB License:
890694
City/State/Zip:
Corona CA 92878
Phone:
951-667-4220
Date Signed:
2024-11-07
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-E20021A-E20A
Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF3R-ENV-20-H
(Page 1 of 4)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Enclosure Air Leakage - General Information
01 Is HERS verification of building enclosure air leakage to outside
required by CF1R?
Required
02 Target Enclosure Air Leakage from CF1R (CFM50)1860
03 Indoor Temperature During Test (degrees Fahrenheit ( °F))70
04 Outdoor Temperature During Test (degrees Fahrenheit ( °F))70
05 Blower Door Location Front Door
06 Building Elevation Above Sea level (feet (ft))56
07 Date of Diagnostic Test for this Dwelling 2025-02-13
08 Test Procedure Used Single-Point Test with Manual Meter
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF3R-ENV-20-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-E20021A-E20A
Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
B. Diagnostic Equipment Information
01 Number of Manometers Used to Measure Home Pressurization 1
02 03 04 05 06
Manometer Make Manometer Model Manometer Serial
Number
Manometer Calibration
Date
Manometer Calibration
Status
RetroTec DM3210A 405286 2024-05-20 Manometer Calibration is
valid
07 Number of Fans Used to Pressurize Home 1
08 09 10 11
Fan Make Fan Model Fan Serial Number Fan Configuration (rings)
RetroTec 1000 1FT005043 b4
ENV20a - Single Point Air Tightness Test With Manual Meter
C. Enclosure Air Leakage Diagnostic Test
01 Time Average Period of Meter (seconds)10
02 Test Methodology Depressurization
03 Pre-test Baseline Enclosure Pressure (Pa) (may be positive or
negative)
0.3
04 Unadjusted Enclosure Pressure Target (Pa)-49.7
05 Unadjusted Enclosure Pressure Measured (Pa) (Pressurization is
positive; Depressuriation is negative)
50
06 Induced Enclosure Pressure Difference (Pa) Goal = 50 +- 3
(Pressurization is positive; Depressuriation is negative)
49.7
07 Induced Enclosure Pressure Check Induced pressure within range for single point test
08 Measured Nominal Fan Flow at Above Fan Pressure (cfm) at the
Induced Enclosure Pressure Difference (in C06 above)
1630
09 Calculated Nominal CFM50 1636
D. Altitude and Temperature Correction
01 Altitude and Temperature Correction Factor 0.998
02 Corrected CFM50 1633
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF3R-ENV-20-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-E20021A-E20A
Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
E. Accuracy Adjustment
01 Adjusted CFM50 (measured air leakage rate)1796
F. Compliance Statement
01 Passes Enclosure Air Leakage Test
G. Additional Requirements For Compliance
01 The procedure for preparing the enclosure for testing is detailed in RESNET 380-2019 Section 3.2.
02 The test procedure for installation of the test apparatus, and preparations for measurement shall conform to RESNET 380-2019 Section
3.3
03 The procedure for the conduct of the enclosure air leakage test shall conform to the One-Point Airtightness Test specified in RESNET
380-2019 Section 3.4.1
04 Verification Status Pass - all applicable requirements are met.
05 Correction Notes
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
H. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
BUILDING AIR LEAKAGE DIAGNOSTIC TEST -
BUILDING ENCLOSURES AND DWELLING
UNIT ENCLOSURES
CF3R-ENV-20-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-E20021A-E20A
Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
Richmond American Homes of California Inc - SoCal
Responsible Builder or Installer Name:
Raymond Weden (authorized Steven Bryant)
CSLB License:
487535
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-14
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-E21005A-E21A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF3R-ENV-21-H
(Page 1 of 6)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Air Barrier Materials
01
A continuous sealed exterior air barrier is required in all thermal envelope assemblies to limit air movement between unconditioned/
outside spaces and conditioned/ inside spaces, and must comply using one of the following methods:
1.Using individual materials that have an air permeance not exceeding 0.004 cfm/ft2 under a pressure differential of 0.3 in. w.g.
(1.57 pcf) (0.02 L/s.m2 at 75 pa) when tested in accordance with ASTM E2178; or
2.Using assemblies of materials and components that have an average air leakage not to exceed 0.04 cfm/ft2 under a pressure
differential of 0.3 in. w.g. (1.57 pcf) (0.2 L/s.m2 at 75 pa) when tested in accordance with ASTM E2357, ASTM E1677, ASTM E1680,
or ASTM E283; or
3.Testing the complete building and demonstrating that the air leakage rate of the building envelope does not exceed 0.40 cfm/ft 2
under a pressure differential of 0.3 in. w.g. (1.57 pcf) (2.0 L/s.m2 at 75 pa) when tested in accordance with ASTM E779 or an
equivalent approved method.
02 Method of Compliance Method 1 (Individual Materials)
03 Verification Status Pass - all applicable requirements are met.
04 Correction Notes
Note:
SPF insulation is an acceptable air barrier and sealant when installed to a minimum thickness of 2 inches for closed cell and 5.5 inches for
open cell, except where not allowed by manufacturer (e.g. flues, vents, can lights, etc).
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
B. Raised Floor Adjacent to Unconditioned Space or Separate Dwelling Units
01 All gaps in the raised floor are sealed.
02 All chases sealed at floor level using a sealed hard cover.
03 All holes (e.g. for plumbing and electrical wires) that penetrate the floor or bottom plates of walls are sealed.
04 Subfloor sheathing is glued or sealed at all panel edges to create a continuous airtight subfloor air barrier.
05 Verification Status n/a
06 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF3R-ENV-21-H
(Page 2 of 6)
Registration Number:
424-P010143661A-000-002-E21005A-E21A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
C. Walls Adjacent to Unconditioned Space
01 All penetrations through the exterior wall air barrier are sealed to provide an airtight envelope to unconditioned spaces such as the
outdoors, attic, garage and crawl space.
02 Exterior wall air barrier is sealed to the top plate and bottom plate in each stud bay.
03 All electrical boxes, including knockouts that penetrate the air barrier to unconditioned space are sealed.
04 All openings in top and bottom plate, including all interior and exterior walls, to unconditioned space are sealed; such as holes drilled for
electrical and plumbing.
05 Exterior bottom plates (all stories) are sealed to the floor.
06 All gaps around windows and doors are sealed. The sealant used follows manufacturer specifications.
07 Rim joist gaps and openings are fully sealed.
08 Fan exhaust duct outlet/ damper at the exterior wall are sealed.
09 Knee walls have solid and sealed blocking at the bottom, top, left and right sides to prevent air movement into insulation.
10 Verification Status Pass - all applicable requirements are met.
11 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
D. Ceiling Air Barrier Adjacent to Unconditioned Space
01 There is a continuous air barrier at the ceiling level. All openings into walls, drops, chases or double walls are sealed.
02 All penetrations through the top plate of interior and exterior walls are sealed.
03 Fire sprinklers penetrating a ceiling air barrier shall be sealed to prevent air movement according to the manufacturer's instructions.
04
All fixtures cut into the ceiling air barrier (e.g. HVAC registers, electrical boxes, fire alarm boxes, exhaust fan housing, and recessed
lighting fixtures) are sealed to the surrounding dry wall. If it is not possible to seal the fixture directly, a secondary air barrier shall be
created around the fixture.
05 All installed recessed lighting fixtures that penetrate the ceiling to unconditioned space are rated to be Insulation Contact and Airtight (IC
and AT) which allow direct contact with insulation.
06 All dropped ceiling areas are covered with hard covers that are sealed to the framing, or else the bottom and sides of dropped ceiling
areas are all insulated and sealed as ceilings and walls as required on the Certificate of Compliance.
07 All vertical chases (e.g. HVAC ducts and plumbing) and soffits are sealed at the ceiling level.
08 Chimneys and flues require sheet metal flashing at the ceiling level. The flashing shall be sealed to the chimney/flue with fire rated caulk.
The flashing shall be sealed to the surrounding framing.
09 Framing locations where air may move down into the walls from the attic (e.g. double walls, pocket doors, architectural bump-outs, etc)
have a sealed hard cover to prevent air movement.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF3R-ENV-21-H
(Page 3 of 6)
Registration Number:
424-P010143661A-000-002-E21005A-E21A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
D. Ceiling Air Barrier Adjacent to Unconditioned Space
10 Attic access forms an airtight seal between the conditioned space and unconditioned space. Vertical attic access requires mechanical
compression using screws or latches.
11 Verification Status Pass - all applicable requirements are met.
12 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
E. Roof Air Barrier - Unvented Attics Adjacent to Unconditioned Space
01 There is a continuous air barrier at the roof deck and gable ends.
02 Chimneys and flues require sheet metal flashing at the roof deck. The flashing shall be sealed to the chimney/flue with fire rated caulk.
The flashing shall be sealed to the surrounding framing.
03 All penetrations in the roof deck and gable ends for plumbing, electrical, etc. are sealed.
04 Verification Status Pass - all applicable requirements are met.
05 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
F. Conditioned Space Above Or Adjacent To Garage Air Barrier
01 All penetrations in the subfloor above the garage into conditioned space must follow the raised floor air barrier requirements above.
02
Infiltration between the space above the garage and subfloor is prevented by one of the following methods:
•Seal all edges of garage ceiling (typically drywall) at the perimeter of the garage to create a continuous airtight surface between
the garage and adjacent conditioned envelope. Seal all plumbing, electric and mechanical penetrations between the garage and
the adjacent conditioned space. For an open-web truss, airtight blocking is added on four sides of the garage perimeter.
Insulation can be placed on the garage ceiling.
•Seal the band joist above the wall at the garage to conditioned space transition. Seal all subfloor seams and penetrations
between the garage and adjacent conditioned space. Insulation must be placed in contact with the subfloor below the
conditioned space.
03 Verification Status n/a
04 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
G. Cantilevered Floor Air Barrier
01 Airtight blocking is installed between joists where the wall rim joist would have been located in the absence of a cantilever.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF3R-ENV-21-H
(Page 4 of 6)
Registration Number:
424-P010143661A-000-002-E21005A-E21A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
G. Cantilevered Floor Air Barrier
02 Exterior sheathing is installed to the bottom of the cantilever so that there is a continuous air and weather barrier for the cantilever. The
cantilevered joist must be insulated to the same R value as would be required for the subfloor prior to closing.
03 Any gaps, cracks or penetrations in the air barrier of the cantilever are sealed. Recessed can lights in the cantilever are rated to be
Insulation Contact and Airtight (IC and AT) and properly sealed to the sheathing.
04 Verification Status n/a
05 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
H. Walls For Attached Porch, Attic, Double Wall Air Barrier
01 An exterior wall air barrier is required at the intersection of the porch and exterior wall when there is conditioned space on the other
side. The exterior wall includes an air barrier where the attic attaches to the conditioned space.
02 Truss framing blocking is used at the top and bottom of each wall/ roof section.
03 Verification Status Pass - all applicable requirements are met.
04 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
I. Special Requirements for SIPs
01 SIPs are considered an air barrier when properly sealed at top, bottom, sides and all penetrations.
02 Air barrier is continuous across all surfaces, including between SIPs and non-SIP sections.
03 Verification Status n/a
04 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
J. Special Requirements for ICF
01 ICF sections are considered an air barrier when properly sealed at top, bottom, sides and all penetrations.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF3R-ENV-21-H
(Page 5 of 6)
Registration Number:
424-P010143661A-000-002-E21005A-E21A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
J. Special Requirements for ICF
02 Air barrier is continuous across all surfaces, including between ICF and non-ICF sections.
03 Verification Status n/a
04 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
K. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - AIR INFILTRATION SEALING - FRAMING
STAGE
CF3R-ENV-21-H
(Page 6 of 6)
Registration Number:
424-P010143661A-000-002-E21005A-E21A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
TruTeam of California
Responsible Builder or Installer Name:
Jessica Ortiz
CSLB License:
1034361
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 1 of 7)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Insulation Materials Installed
01 Roof Deck Insulation Material Installed Batt and Blanket
02 Ceiling Insulation Material Installed Batt and Blanket
03 Exterior Wall Insulation Material Installed Batt and Blanket
04 Raised Floor Insulation Material Installed n/a
05 Slab Edge Insulation Material Installed Rigid Board
06 Verification Status Pass - all applicable requirements are met.
B. All Surfaces
01 Air barrier installation and preparation for insulation was done and verified prior to insulation being installed.
02 All surfaces between conditioned and unconditioned space are sealed and insulated to meet or exceed the levels specified on the
Certificate of Compliance
03
All structural framing areas shall be insulated in a manner that resists thermal bridging through the assembly separating conditioned
from unconditioned space. Structural bracing, tie-downs, and framing of steel, or specialized framing used to meet structural
requirements of the California Building Code (CBC) are allowed and must be insulated. These areas shall be called out on the building
plans with diagrams and/ or specified design drawings indicating the R-value of insulation and fastening method to be used.
04 All insulation was installed according to the manufacturer's installation instructions.
05 Labels or specification/ data sheets for each insulation material shall be provided to the HERS rater. Loose-fill material includes insulation
material bag labels or coverage charts.
06
Loose-fill insulation - the installed depth and density of insulation is verified in at least 6 random locations to ensure that the minimum
thickness and installed density meet R-value specified on the Certificate of Compliance, and are consistent with the manufacturer's
coverage chart.
07 If kraft paper faced insulation is used, paper is installed on the conditioned (warm in winter) side of surface. Paper must be in contact
with air barrier to within 2-inches of the framing (stud, joists, etc.).
08 Verification Status Pass - all applicable requirements are met.
09 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 2 of 7)
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
C. Raised Floor Adjacent to Unconditioned Space
01 Insulation is in full contact with the subfloor.
02 Insulation hangers are spaced at 18 inches or less. Insulation hangers do not compress insulation.
03 Netting, or mesh, can be used if the cavity under the floor is filled and in contact with the subfloor.
04 When daylit basements are adjacent to crawlspaces, if the basement is conditioned the walls adjacent to the crawlspace are insulated to
the R-value listed on the Certificate of Compliance. This includes framed stem walls, and vertical concrete retaining walls.
05 If access to the crawlspace is from the conditioned area the raised floor includes an airtight insulated access hatch. Where possible locate
crawl space access on the exterior.
06 Verification Status n/a
07 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
D. Walls Adjacent to Unconditioned Space
01 Insulation quality was verified prior to the installation of the interior air barrier (typically gypsum board).
02
Loose-fill and batt insulation is in contact with all six sides of wall cavities (top, bottom, back, left, right, front [to be installed later]) with
no gaps, voids or compression. Special Situation: Where framing depth is greater than required insulation thickness (e.g., double walls or
framed bump-outs) a secondary air barrier shall be installed and in contact with the insulation, so that the insulation fills the cavity
formed by the additional air barrier.
03 Insulation fits snuggly around obstructions (e.g., electrical boxes, plumbing and wiring) with no gaps, voids or compression.
04 Structural metal tie-downs and shear panels are insulated between exterior air barrier and metal.
05 Hard to access wall stud cavities, such as corner channels or wall intersections, are insulated to the proper R-value prior to the
installation of exterior sheathing or exterior stucco lathe.
06 Insulation and interior air barrier are installed behind tub, shower, fireplace enclosures and stairwells to the R-value listed on the
Certificate of Compliance when located against exterior walls.
07
All single-member window and door headers shall be insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a
minimum of R-5 for all other assemblies. No header insulation is required for single-member headers that are the same width as the wall,
provided that the entire wall has at least R-2 insulation.
08 After insulation is installed: All insulated walls have interior and exterior air barriers, including kneewalls and walls of skylight wells.
Exception: Rim joists. Interior air barrier (typically gypsum board) is sealed to top plate.
09 Verification Status Pass - all applicable requirements are met.
10 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 3 of 7)
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
E. Ceiling Adjacent to Unconditioned Space
01 Insulation extends to the outside surface of the exterior wall.
02 Insulation is in direct contact with the ceiling air barrier so there are no gaps, voids or compression.
03
Chimneys and flues (except zero clearance) have a sheet metal collar at the ceiling level to prevent contact with the insulation. The collar
is at least as tall as the depth of the insulation. There is a minimum 1-inch clearance between the collar and the chimney/flue for double
wall vent, and 6-inches for single wall vent, unless manufacturer's instructions require otherwise. The collar is sealed to the ceiling with
high temperature sealant to prevent air leakage. The insulation is in contact with the sheet metal collar.
04 Recessed can lights penetrating the ceiling air barrier are covered with insulation to the depth needed to meet the ceiling R-value
specified on the Certificate of Compliance.
05 External surfaces of steel studs, steel-framed kneewalls, skylight shafts, and gable ends are covered with insulation.
06 Verification Status Pass - all applicable requirements are met.
07 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
F. Ceiling Insulation in Vented Attics
01 Required eave ventilation shall not be obstructed. The net-free ventilation area of the eave vent is maintained.
02 Eave vent baffles and dams are installed to prevent air movement under or into the ceiling insulation.
03 Attic access is insulated to the same R-value required by the Certificate of Compliance for ceiling insulation and the insulation is
permanently attached using adhesive or mechanical fasteners.
04 Attic access must have a dam around the access to at least the same depth as the insulation.
05
Attic rulers specified to the installed loose-fill material (brand and type) are installed and evenly distributed throughout the attic to verify
depth (one ruler for every 250 square feet (ft2)). The rulers are clearly readable and scaled to read inches of insulation and the R-value
installed.
06 Verification Status Pass - all applicable requirements are met.
07 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
G. Insulation in unvented Attics
01 The roof sheathing is the air barrier and is sealed to prevent air movement to the outside.
02 Insulation is in full contact with the air barrier (roof sheathing).
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 4 of 7)
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
G. Insulation in unvented Attics
03 If insulated using air permeable insulation, gable end walls are sealed and insulated the same as exterior walls, including interior air
barrier.
04 Verification Status Pass - all applicable requirements are met.
05 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
H. Insulation in Vented Attics (High Performance Vented Attics)
01 Insulation is in full contact with roof sheathing and firmly supported to prevent sagging.
02 Batt insulation between roof trusses is acceptable with minimal gaps and voids caused by roof truss members.
03 Insulation is not required on gable end walls.
04
Required roof deck insulation over any conditioned space, or HVAC ducts, is installed on the entire attic roof deck; even over
unconditioned spaces (e.g., garage, covered porch). Roof deck of attic over unconditioned space without HVAC ducts and separated from
other attics by a sealed air barrier do not need to be insulated.
05 Verification Status Pass - all applicable requirements are met.
06 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
I. Special Requirements for Skylight Shafts and Attic Knee Walls
01 Insulation must meet all the requirements for walls and insulation is in contact with the air barrier on all six sides unless SPF is used.
02 Insulation shall be in full contact with the interior wall finish. Batt insulation must be cut to fit around 2x4's that are laid flat.
03 Skylight shafts and attic knee walls shall be completely enclosed by vertical and horizontal framing, including horizontal plates at the top
and bottom of the insulation.
04 Verification Status n/a
05 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 5 of 7)
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
J. Special Requirements for Floors Above Garages
01 If the air barrier is at the perimeter of the garage below the conditioned subfloor, then the insulation may be placed on the garage
ceiling. The perimeter of the subfloor must also be insulated.
02 Verification Status n/a
03 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
K. Special Requirements for Cantilevered Floors
01 Sealed blocking shall be installed between joists where the wall rim joist would have been located in the absence of a cantilever.
Insulation shall be placed on both sides of the block.
02 Verification Status n/a
03 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
L. Special Requirements for Attached Porches
01 Exterior wall at the intersection of the porch roof is fully insulated above, below and behind the roof line.
02 Where truss framing is used, airtight blocking is used at the top and bottom of each wall/ roof section and is insulated.
03 Verification Status n/a
04 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
M. Special Requirements for SPF Insulation
01 Installed product meets the claimed R-value per inch. The total R-value may be calculated based on the thickness of insulation multiplied
by the "tested R-value per inch" as certified by the Department of Consumer Affairs, Bureau of Household Goods and Services.
02 Installed thickness meets the required R-value from the Certificate of Compliance. Verified in at least 6 random places for each surface
type: floors, walls and ceilings.
03 Insulation is spray applied to fully adhere to structural assembly framing, floor and ceiling joists, and other framing surfaces within the
construction cavity.
04 If multiple layers are applied, each foam lift (e.g., spray application) adheres to the substrate and foam interfaces.
05 Closed cell SPF: In area where an air barrier is required the foam is at least 2-inches thick.
06 Open cell SPF: In area where an air barrier is required the foam is at least 5.5-inches thick.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 6 of 7)
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
M. Special Requirements for SPF Insulation
07 Open cell SPF: Depressions in the foam insulation are not greater than 1/2-inch of the required thickness provided these depressions do
not exceed 10% of the surface area being insulated.
08 Open cell SPF: Insulation completely fills cavities of 2x4 framing.
09
SPF insulation is not applied directly to recessed lighting fixtures unless specifically allowed by manufacturer's instructions. when not
allowed, can lights are:
A.Covered with a minimum of 1.5-inches of mineral fiber insulation or
B.Enclosed in a manufacturer's approved box fabricated from an approved material, such as 18 gauge sheet metal or 1/2-inch
gypsum board.
10 Verification Status n/a
11 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Correction Notes.
N. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
QII - INSULATION INSTALLATION CF3R-ENV-22-H
(Page 7 of 7)
Registration Number:
424-P010143661A-000-002-E22006A-E22A
Registration Date/Time: 2025-02-18 15:04:51 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
TruTeam of California
Responsible Builder or Installer Name:
Jessica Ortiz
CSLB License:
1034361
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M27010A-M27A
Registration Date/Time: 2025-02-19 13:22:29 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:46
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF3R-MCH-27-H
(Page 1 of 3)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ANSI/ASHRAE Standard
62.2.-2019 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings subject to amendments specified by Title 24, Part 6
Section 150.0(o)1.
A. Whole-Dwelling Mechanical Ventilation - General Information
01 Dwelling unit name Single Family Dwelling
02 Building Type Single family detached
03 Project scope Newly Constructed
04
Total Conditioned Floor Area of Dwelling Unit
(For addition projects the conditioned floor area equals existing
area plus addition area. )
3066
05
Number of Bedrooms in Dwelling Unit
(For addition projects the number of bedrooms equals the existing
bedrooms plus addition bedrooms)
4
06 Ventilation System Type Balanced
07 Ventilation Operation Schedule Continuous
Note:
Non-dwelling units do not meet the definition for a dwelling unit as defined in Section 100.1(b). Non-dwelling units are not designed to provide
independent living facilities and do not provide permanent provisions for living, sleeping, eating, cooking and sanitation.
MCH-27a - Single Family Attached/Detached
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF3R-MCH-27-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M27010A-M27A
Registration Date/Time: 2025-02-19 13:22:29 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:46
B. Single Family Attached/Detached General Information
01 Average Ceiling Height 9.1
02 Total Conditioned Volume 27900.6
03 Vertical distance between the lowest and highest above grade
points within the pressure boundary in feet
9.1
04 Air Changes Per Hour at 50 Pa Default
05 Name of ANSI/ASHRAE Standard 62.2-2019 weather station for
climate zone
Palm Springs Intl
06 Weather and shielding factor (wsf) (Based on city identified above)0.45
C. Ventilation - Total Ventilation Rate
A mechanical supply system, exhaust system or combination thereof shall provide whole-dwelling ventilation with outdoor air each hour at no
less than the rate in 150.0(o)1Ci
01 Total Required Ventilation Rate (Qtot)129.48
02 Enclosure Leakage Rate (Q50)930.02
03 Effective Annual Average Infiltration Rate (Qinf 22.69
04 Total Exterior Envelope Surface Area n/a
05 Unshared Exterior Envelope Surface Area (exclude surface areas
attached to garages or other dwelling units)
n/a
06 Required Mechanical Ventilation Rate (Qfan)106.79
D. Installed Ventilation - Total Ventilation Rate
A mechanical supply system, exhaust system, or combination thereof shall provide whole-dwelling ventilation with outdoor air
each hour at no less than the rate in 150.0(o)1Ci
01 02 03 04 05
Fan Name Fan Location Runtime (min/hr)Installed Mechanical
Ventilation Rate (CFM)
Equivalent Continuous
Ventilation (CFM)
NA ATTIC 60 131 131
06 Total Installed Continuous Ventilation (CFM)131
E. Compliance Statement
01 Building Passes Mechanical Ventilation RateTest
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
INDOOR AIR QUALITY AND MECHANICAL
VENTILATION
CF3R-MCH-27-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M27010A-M27A
Registration Date/Time: 2025-02-19 13:22:29 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:46
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Angelia Long
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-19
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-19
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 424-P010143661A-000-002-M32022A-M32A Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
LOCAL MECHANICAL EXHAUST CF3R-MCH-32-H
(Page 1 of 3)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
Title 24, Part 6, Section 150.0(o)Ventilation for Indoor Air Quality.All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in
Residential Buildings, subject to the amendments specified in Section 150.0(o)1.
A. Local Mechanical Exhaust - General Information
01 Dwelling unit name Single Family Dwelling
02 Building Type Single family detached
03 Total Kitchen Floor Area 0
04 Kitchen Average Ceiling Height 0
05 Kitchen Total Conditioned Volume 0
06 Kitchen Type Non-Enclosed
07 Dwelling Unit Total Floor Area 3066
08 Kitchen Range (Cooking Stove) Fuel Type Electric
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
LOCAL MECHANICAL EXHAUST CF3R-MCH-32-H
(Page 2 of 3)
Registration Number: 424-P010143661A-000-002-M32022A-M32A Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
B. Kitchen Exhaust System
01 02 03 04 05 06 07 08 09 10 11 12 13
System
Name
Manufacturer
Name System Type
HVI or AHAM
Directory
Listed Model
Number
HVI or AHAM
Directory
Listed Rated
Airflow
HVI or AHAM
Directory
Listed Sound
Rating
Minimum
Airflow
(defaults to
rated
airflow)
Operation
Schedule
Method of
Compliance
Required
Minimum
Ventilation
Rate (if
demand
controlled)
Exception to
Maximum
Sound Rating
Compliance
Statement
for Airflow
Compliance
Statement
for Sound
Hood 1 GE Vented Range
Hood JVW5361SJSS 250 3.0 150 Demand
Control Airflow 110 3 sone Complies Complies
C. Continuous Kitchen Exhaust
01 Total Continuous Ventilation Airflow n/a
02 Required Minimum Continuous Ventilation Airflow n/a
03 Compliance Statement n/a
D. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to
be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
LOCAL MECHANICAL EXHAUST CF3R-MCH-32-H
(Page 3 of 3)
Registration Number: 424-P010143661A-000-002-M32022A-M32A Registration Date/Time: 2025-02-14 15:42:11 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:24
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:Energy Inspectors Corporation Date Signed:2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:Las Vegas NV 89117 Phone:(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the
applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements
specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for
all applicable inspections, and I will take the necessary steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy, and I will take the necessary
steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):Richmond American Homes of California Inc - SoCal
Responsible Builder or Installer Name:
Raymond Weden (authorized Steven Bryant)
CSLB License:
487535
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-14
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M20011A-M20A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
DUCT LEAKAGE DIAGNOSTIC TEST CF3R-MCH-20-H
(Page 1 of 3)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served living 1
03 Indoor Unit Name or Description of Area Served living 1
04 Building Type from parent CC Single family
05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit
from parent CC?
No, credit is not taken
06 Verified Low Leakage Air Handling Unit Credit from parent CC?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be
used
07 Duct System Compliance Category New
08 Portions of Duct Located in Garage?No
09 Is the system type Small Duct High Velocity (SDHV) ?No
MCH-20c - Low Leakage Air-Handling Unit (LLAHU)
B. Duct Leakage Diagnostic Test
01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method
02 Condenser Nominal Cooling Capacity (ton)5
03 Indoor Unit Nominal Cooling Capacity n/a
04 Heating Capacity (kBtu/h)n/a
05 Conditioned Floor Area Served by this HVAC System (ft2)3066
06 Measured AHU Airflow (cfm)n/a
07 Duct Leakage Test Conditions Test final
08 Duct Leakage Test Method Total leakage
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF3R-MCH-20-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M20011A-M20A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
B. Duct Leakage Diagnostic Test
09 Leakage Factor 0.05
10 Calculated Target Allowable Duct Leakage (cfm)100
11 Actual Duct Leakage Rate from Leakage Test Measurement
(cfm)
48
12 Air Handling Unit Manufacturer Name GOODMAN
13 Air Handling Unit Model Number GM9S960805
14 Compliance Statement System passes leakage test
15 Notes:
C. Additional Requirements for Compliance
01
The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage
Air-Handling Units published on the Energy Commission Website at:
http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf
02 System was tested in its normal operation condition. No temporary taping allowed.
03
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA
ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize
dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the
closed position during duct leakage testing.
04 All supply and return register boots were sealed to the drywall.
05 Building cavities were not used as plenums or platform returns in lieu of ducts.
06 If cloth backed tape was used it was covered with Mastic and draw bands.
07 All connection points between the air handler and the supply and return plenums are completely sealed.
08 Verification Status:Pass - all applicable requirements are met.
09 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
D. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF3R-MCH-20-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M20011A-M20A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M23012A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 1 of 4)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served living 1
03 Indoor Unit Name living 1
04 System Installation Type New
05 Nominal Cooling Capacity (tons)5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum.
Procedures for installing HSPP or PSPP are specified in RA3.3.1.1.
01 Method Used to Demonstrate Compliance with the HSPP/PSPP
Requirement
HSPP installed and labeled consistent with Figure RA3.3-1
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-M23012A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
C. Airflow Rate Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2.
01 Airflow Rate Measurement Type used for this airflow rate
verification.
Traditional Flow Capture Hood according to procedure in
RA3.3.3.1.4
02 Manufacturer of Airflow Measurement Apparatus Testo
03 Model number of Airflow Measurement Apparatus 420
04
Certification Status of the Airflow Measurement Apparatus
Accuracy
Certified by Manufacturer and listed on CEC Website at
http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index.
html
MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
D. Forced Air System Airflow Rate Measurement
The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3.
01 Required Minimum System Airflow Rate (cfm/ton)350
02 Required Minimum System Airflow Target (cfm)1750
03 Actual System Airflow Rate Measurement (cfm)1755
04 Compliance Statement:System airflow rate complies
E. Additional Requirements
01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system
during system air flow rate measurement identified on this Certificate of Verification.
02
The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was
calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in
RA3.3.1.
03
A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return
duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an
allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate
shall conform to the specifications listed on the Certificate of Compliance.
04 All registers were fully open during the diagnostic test.
05 System fan was set at maximum speed during the diagnostic test.
06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-M23012A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
E. Additional Requirements
08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
09 Verification Status:Pass - all applicable requirements are met.
10 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table
F. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-M23012A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M22013A-M22A
Registration Date/Time: 2025-02-18 15:04:53 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:11
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF3R-MCH-22-H
(Page 1 of 3)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 System Identification or Name HVAC1
02 System Location or Area Served living 1
03 Indoor Unit Name or Description of Area Served living 1
04 System Installation Type New
05 Nominal Cooling Capacity (tons) of Condenser 5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Fan Watt Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2.
01 Fan Watt Verification Device Used.Digital Utility Revenue Meter
MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF3R-MCH-22-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M22013A-M22A
Registration Date/Time: 2025-02-18 15:04:53 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:11
C. Forced Air System Fan Efficacy Measurement
The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3
01 Actual Tested Watts 770
02 Actual Tested Airflow from MCH-23 (cfm)1755
03 Required Fan Efficacy (Watts/cfm)0.45
04 Actual Fan Efficacy (watts/cfm)0.44
05 Compliance Statement:System fan efficacy complies
D. Additional Requirements
01 All registers were fully open during the diagnostic test.
02 System fan was set at maximum speed during the diagnostic test.
03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm)
criteria in every zonal control mode.
07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data
acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater
08 Verification Status Pass - all applicable requirements are met.
09 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
E. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF3R-MCH-22-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M22013A-M22A
Registration Date/Time: 2025-02-18 15:04:53 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:11
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M25017A-M25A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:12
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 1 of 4)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served living 1
03 Condenser (or package unit) make or brand GOODMAN
04 Condenser (or package unit) model number GSXH506010
05 Nominal Cooling Capacity (tons) of Condenser 5
06 Condenser (or package unit) serial number NA
07 Refrigerant Type R-410A
08 Other Refrigerant Type (if applicable)n/a
09 Liquid Line Filter Drier Installed According to Manufacturers
Specifications (if applicable)
Yes
10 System Installation Type New
11 Fault Indicator Display (FID) Status (Note: Even systems with a FID
must have refrigerant charge verified by installer)
This system does not have a FID device installed
12
Is the system of a type that the minimum airflow can be verified for
all indoor units using an approved measurement procedure (RA3.3
or RA3.3.3)?
Yes
13
Is the system of a type that approved refrigerant charge verification
procedures can be used to verify compliance with the refrigerant
charge verification requirements when temperatures are >= 55 °F
(RA3.2.2, or RA1)?
Yes, one of the Refrigerant charge verification procedures from
RA3.2.2 or RA1 is applicable to this system and can be used to
verify compliance
14 Date of Refrigerant Charge Verification for this system 2025-02-04
15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than
55 degF)
16 Person who performed the Refrigerant Charge Verification
reported on this Certificate of Installation
HVAC system installer
17 HERS Verification Compliance Requirement Status System qualifies for group sampling
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-M25017A-M25A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:12
A. System Information
HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry.
18 Refrigerant charge verification method used by HERS Rater.Subcooling
MCH-25b - Refrigerant Charge Verification - Subcooling Method
B. Metering Device Verification
HERS Rater is required to visually field verify all information from CF2R. Subcooling Method can only be used on systems that have a variable
metering device.
01 Refrigerant metering device Thermostatic Expansion Valve (TXV)
02 Subcooling Method applicability status Subcooling Method is applicable to this system.
C. Instrument Calibration
HERS Raters are required to calibrate their diagnostic tools. Procedures for instrument calibration are given in Reference Residential Appendix
RA3.2.2 and RA3.2.2.2
01 Date of Digital Refrigerant Gauge Calibration 2025-02-01
02 Date of Digital Thermocouple Calibration 2025-02-01
03 Digital Refrigerant Gauge Calibration Status Calibration is current
04 Digital Thermocouple Calibration Status Calibration is current
D. Measurement Access Hole (MAH) Verification
HERS Raters are required to visually field verify MAH. Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3
01 Method Used to Demonstrate Compliance with the Measurement
Access Hole (MAH) Requirement
MAH installed and labeled consistent with Figure 3.2-1
E. Minimum System Airflow Rate Verification
Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3.
01 02 03
Indoor Unit Name or Description of Area
Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status
living 1 1750 System complies with minimum airflow rate
requirements
04 SC System complies with Minimum System Airflow Rate Verification
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-M25017A-M25A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:12
F. Data Collection and Calculations
HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge
Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2
01 Lowest Return Air Dry Bulb Temperature that Occurred During the
Refrigerant Charge Verification Procedure ( °F)
70
02 Measured Condenser Air Entering Dry-Bulb Temperature
(Tcondenser, db)
60
03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling
refrigerant charge verification method
04 Measured Liquid Line Temperature (Tliquid) ( °F)66
05 Measured Liquid Line Pressure (Pliquid) (psig)206
06 Condenser Saturation Temperature (Tcondenser, sat) from Digital
Gauge or P-T Table using Line F05 ( °F)
71
07 Measured Subcooling (Line F06 - Lilne F04 ( °F)5
08 Target Subcooling from Manufacturer ( °F)6
09 Compliance Statement:System complies with Subcooling Method - Must also pass
metering device verification, next section
G. Metering Device Verification
HERS Rater must independently collect all data in this section. Procedures for the verification of proper metering device operation are specified
in RA3.2.2.6.2
01 Measured Suction Line Temperature (Tsuction) ( °F)34
02 Measured Suction Line Pressure (Psuction) (psig)96
03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital
Gauge or P-T Table using Line G02 ( °F)
30
04 Measured Superheat (Line G01- Line G03) ( °F)4
05 Measured Superheat (Line G04) is between 3 °F and 26 °F
(inclusive)
Passes CEC requirement
06 Measured Superheat (Line G04) is within Manufacturer's
Specifications ( if known)
Yes, documentation to be provided upon request
07 Compliance Statement:Metering device verification passes
H. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-M25017A-M25A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M26018A-M26A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 1 of 5)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
Procedures for verification of High SEER/SEER2 and EER/EER2 Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring
verification must use a separate form.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served living 1
03 Efficiency Metric EER2/SEER2
04 Status: SEER/SEER2 Performance Compliance Credit Check Yes
05 Status: EER/EER2 Performance Compliance Credit Check Yes
06 Status: Heat Pump Heating Output Performance Compliance Check No
07 Status: HSPF/HSPF2 Performance Compliance Credit Check No
08 Directory used to certify product performance AHRI
09 AHRI certification number for the installed space conditioning
system from http://www.ahridirectory.org
214287336
10 Does the directory used to certify product performance require a
specific air handler/furnace make and model?
Furnace air-handling unit
11 Does the directory used to certify product performance require a
time delay relay (+TDR)?
Yes
12 Does the directory used to certify product performance require a
TXV (+TXV)?
Yes
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 2 of 5)
Registration Number:
424-P010143661A-000-002-M26018A-M26A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System
The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to
certify product performance in order to demonstrate compliance.
01 02 03 04
Data from Nameplate of Installed System Component
05 06 07 08 09 10
SC System
ID/Name
from CF1R
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 living 1 living 1 AC Coil GOODMAN GSXH50601
0 GOODMAN CP61C34 GOODMAN GM9S96080
5
C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance
The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used
to certify product performance in order to demonstrate compliance.
01 02 03 04
Data from the Directory used to certify product performance for the rated system
component
05 06 07 08 09 10
SC System
ID/Name on
CF1R
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 living 1 living 1 AC Coil GOODMAN GSXH50601
0A*ASPEN CP61C34+T
DR GOODMAN GM9S96080
5CUA*
D. Verified Cooling System SEER/SEER2
01 Required minimum SEER/SEER2 15.2
02 Installed SEER/SEER2 15.2
03 Compliance Statement:System Passes SEER/SEER2 Verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent MCH-26 Certificate of Installation
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 3 of 5)
Registration Number:
424-P010143661A-000-002-M26018A-M26A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
E. Verified Cooling System EER/EER2
01 Required minimum EER/EER2 12.5
02 Installed EER/EER2 12.5
03 Compliance Statement:System passes EER/EER2 verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent MCH-26 Certificate of Installation.
F. Verified Heat Pump Heating Output
This section does not apply to this project.
G. Verified Heat Pump HSPF/HSPF2
This section does not apply to this project.
H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil
01
If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person
certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of
Certified Product Performance.
02 Verification Status:Pass - all applicable requirements are met.
03 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
I. Verified Space Conditioning System Time Delay Relay
01
If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this
compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of
RA3.4.3.
02 Verification Status:Pass - all applicable requirements are met.
03 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 4 of 5)
Registration Number:
424-P010143661A-000-002-M26018A-M26A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
J. Verified Space Conditioning System TXV
01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance
document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb.
02 Verification Status:Pass - all applicable requirements are met.
03 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
K. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 5 of 5)
Registration Number:
424-P010143661A-000-002-M26018A-M26A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Angelia Long
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-19
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-19
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M20014A-M20A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
DUCT LEAKAGE DIAGNOSTIC TEST CF3R-MCH-20-H
(Page 1 of 3)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served LIVING 2
03 Indoor Unit Name or Description of Area Served LIVING 2
04 Building Type from parent CC Single family
05 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit
from parent CC?
No, credit is not taken
06 Verified Low Leakage Air Handling Unit Credit from parent CC?Low Leakage Air Handling Unit (LLAHU) method Mch20c should be
used
07 Duct System Compliance Category New
08 Portions of Duct Located in Garage?No
09 Is the system type Small Duct High Velocity (SDHV) ?No
MCH-20c - Low Leakage Air-Handling Unit (LLAHU)
B. Duct Leakage Diagnostic Test
01 Air Handling Unit Airflow (AHU Airflow) Determination Method Cooling system method
02 Condenser Nominal Cooling Capacity (ton)5
03 Indoor Unit Nominal Cooling Capacity n/a
04 Heating Capacity (kBtu/h)n/a
05 Conditioned Floor Area Served by this HVAC System (ft2)0
06 Measured AHU Airflow (cfm)n/a
07 Duct Leakage Test Conditions Test final
08 Duct Leakage Test Method Total leakage
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF3R-MCH-20-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M20014A-M20A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
B. Duct Leakage Diagnostic Test
09 Leakage Factor 0.05
10 Calculated Target Allowable Duct Leakage (cfm)100
11 Actual Duct Leakage Rate from Leakage Test Measurement
(cfm)
41
12 Air Handling Unit Manufacturer Name GOODMAN
13 Air Handling Unit Model Number GM9S960603
14 Compliance Statement System passes leakage test
15 Notes:
C. Additional Requirements for Compliance
01
The Low Leakage Air-handling Unit Model identified on this compliance document is included in the list of certified Low Leakage
Air-Handling Units published on the Energy Commission Website at:
http://www.energy.ca.gov/title24/equipment_cert/llahu/low_leakage_air_handling_units.pdf
02 System was tested in its normal operation condition. No temporary taping allowed.
03
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA
ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize
dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the
closed position during duct leakage testing.
04 All supply and return register boots were sealed to the drywall.
05 Building cavities were not used as plenums or platform returns in lieu of ducts.
06 If cloth backed tape was used it was covered with Mastic and draw bands.
07 All connection points between the air handler and the supply and return plenums are completely sealed.
08 Verification Status:Pass - all applicable requirements are met.
09 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
D. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
DUCT LEAKAGE DIAGNOSTIC TEST CF3R-MCH-20-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M20014A-M20A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:07
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M23015A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 1 of 4)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served LIVING 2
03 Indoor Unit Name LIVING 2
04 System Installation Type New
05 Nominal Cooling Capacity (tons)2.5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum.
Procedures for installing HSPP or PSPP are specified in RA3.3.1.1.
01 Method Used to Demonstrate Compliance with the HSPP/PSPP
Requirement
HSPP installed and labeled consistent with Figure RA3.3-1
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-M23015A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
C. Airflow Rate Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2.
01 Airflow Rate Measurement Type used for this airflow rate
verification.
Traditional Flow Capture Hood according to procedure in
RA3.3.3.1.4
02 Manufacturer of Airflow Measurement Apparatus Testo
03 Model number of Airflow Measurement Apparatus 420
04
Certification Status of the Airflow Measurement Apparatus
Accuracy
Certified by Manufacturer and listed on CEC Website at
http://www.energy.ca.gov/title24/equipment_cert/ama_fas/index.
html
MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
D. Forced Air System Airflow Rate Measurement
The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3.
01 Required Minimum System Airflow Rate (cfm/ton)350
02 Required Minimum System Airflow Target (cfm)875
03 Actual System Airflow Rate Measurement (cfm)1122
04 Compliance Statement:System airflow rate complies
E. Additional Requirements
01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system
during system air flow rate measurement identified on this Certificate of Verification.
02
The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was
calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in
RA3.3.1.
03
A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return
duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an
allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate
shall conform to the specifications listed on the Certificate of Compliance.
04 All registers were fully open during the diagnostic test.
05 System fan was set at maximum speed during the diagnostic test.
06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-M23015A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
E. Additional Requirements
08 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
09 Verification Status:Pass - all applicable requirements are met.
10 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table
F. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM AIRFLOW
RATE
CF3R-MCH-23-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-M23015A-M23A
Registration Date/Time: 2025-02-18 15:04:52 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:08
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M22016A-M22A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:11
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF3R-MCH-22-H
(Page 1 of 3)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. Ducted Cooling System Information
01 System Identification or Name HVAC1
02 System Location or Area Served LIVING 2
03 Indoor Unit Name or Description of Area Served LIVING 2
04 System Installation Type New
05 Nominal Cooling Capacity (tons) of Condenser 2.5
06 Condenser Speed Type Single Speed
07 Cooling System Zonal Control Type Not Zonal
08 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system
09 System Bypass Duct Status No Bypass Duct
10 Date of System Airflow Rate Measurement 2025-02-04
11 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement
12 Central Fan Ventilation Cooling System Status Not a CFVCS
B. Fan Watt Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2.
01 Fan Watt Verification Device Used.Digital Utility Revenue Meter
MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non-Zoned Systems or Zoned Multi-Speed Compressor
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF3R-MCH-22-H
(Page 2 of 3)
Registration Number:
424-P010143661A-000-002-M22016A-M22A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:11
C. Forced Air System Fan Efficacy Measurement
The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3
01 Actual Tested Watts 392
02 Actual Tested Airflow from MCH-23 (cfm)1122
03 Required Fan Efficacy (Watts/cfm)0.45
04 Actual Fan Efficacy (watts/cfm)0.35
05 Compliance Statement:System fan efficacy complies
D. Additional Requirements
01 All registers were fully open during the diagnostic test.
02 System fan was set at maximum speed during the diagnostic test.
03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
05 Multi-speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy
(Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed.
06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm)
criteria in every zonal control mode.
07 Portable watt meters used for measurements of air handler watt draws shall be true power measurement systems (i.e. sensor plus data
acquisition system) having an accuracy of +- 2% of reading or +- 10 Watts whichever is greater
08 Verification Status Pass - all applicable requirements are met.
09 Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
E. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
SPACE CONDITIONING SYSTEM FAN
EFFICACY
CF3R-MCH-22-H
(Page 3 of 3)
Registration Number:
424-P010143661A-000-002-M22016A-M22A
Registration Date/Time: 2025-02-18 15:04:54 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-18 15:06:11
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-18
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M25019A-M25A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 1 of 4)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Location or Area Served LIVING 2
03 Condenser (or package unit) make or brand GOODMAN
04 Condenser (or package unit) model number GSXH503010
05 Nominal Cooling Capacity (tons) of Condenser 2.5
06 Condenser (or package unit) serial number NA
07 Refrigerant Type R-410A
08 Other Refrigerant Type (if applicable)n/a
09 Liquid Line Filter Drier Installed According to Manufacturers
Specifications (if applicable)
Yes
10 System Installation Type New
11 Fault Indicator Display (FID) Status (Note: Even systems with a FID
must have refrigerant charge verified by installer)
This system does not have a FID device installed
12
Is the system of a type that the minimum airflow can be verified for
all indoor units using an approved measurement procedure (RA3.3
or RA3.3.3)?
Yes
13
Is the system of a type that approved refrigerant charge verification
procedures can be used to verify compliance with the refrigerant
charge verification requirements when temperatures are >= 55 °F
(RA3.2.2, or RA1)?
Yes, one of the Refrigerant charge verification procedures from
RA3.2.2 or RA1 is applicable to this system and can be used to
verify compliance
14 Date of Refrigerant Charge Verification for this system 2025-02-12
15 Refrigerant charge verification method used.Subcooling (outdoor temperature must be equal to or greater than
55 degF)
16 Person who performed the Refrigerant Charge Verification
reported on this Certificate of Installation
HVAC system installer
17 HERS Verification Compliance Requirement Status System qualifies for group sampling
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 2 of 4)
Registration Number:
424-P010143661A-000-002-M25019A-M25A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
A. System Information
HERS Rater to field-verify all system information, discrepancies to be noted by overwriting entry.
18 Refrigerant charge verification method used by HERS Rater.Subcooling
MCH-25b - Refrigerant Charge Verification - Subcooling Method
B. Metering Device Verification
HERS Rater is required to visually field verify all information from CF2R. Subcooling Method can only be used on systems that have a variable
metering device.
01 Refrigerant metering device Thermostatic Expansion Valve (TXV)
02 Subcooling Method applicability status Subcooling Method is applicable to this system.
C. Instrument Calibration
HERS Raters are required to calibrate their diagnostic tools. Procedures for instrument calibration are given in Reference Residential Appendix
RA3.2.2 and RA3.2.2.2
01 Date of Digital Refrigerant Gauge Calibration 2025-02-01
02 Date of Digital Thermocouple Calibration 2025-02-01
03 Digital Refrigerant Gauge Calibration Status Calibration is current
04 Digital Thermocouple Calibration Status Calibration is current
D. Measurement Access Hole (MAH) Verification
HERS Raters are required to visually field verify MAH. Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3
01 Method Used to Demonstrate Compliance with the Measurement
Access Hole (MAH) Requirement
MAH installed and labeled consistent with Figure 3.2-1
E. Minimum System Airflow Rate Verification
Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3.
01 02 03
Indoor Unit Name or Description of Area
Served Minimum Required System Airflow Rate (cfm)System Airflow Rate Verification Status
LIVING 2 1750 System complies with minimum airflow rate
requirements
04 SC System complies with Minimum System Airflow Rate Verification
Notes:
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 3 of 4)
Registration Number:
424-P010143661A-000-002-M25019A-M25A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
F. Data Collection and Calculations
HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge
Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2
01 Lowest Return Air Dry Bulb Temperature that Occurred During the
Refrigerant Charge Verification Procedure ( °F)
70
02 Measured Condenser Air Entering Dry-Bulb Temperature
(Tcondenser, db)
64
03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling
refrigerant charge verification method
04 Measured Liquid Line Temperature (Tliquid) ( °F)66
05 Measured Liquid Line Pressure (Pliquid) (psig)215
06 Condenser Saturation Temperature (Tcondenser, sat) from Digital
Gauge or P-T Table using Line F05 ( °F)
71
07 Measured Subcooling (Line F06 - Lilne F04 ( °F)5
08 Target Subcooling from Manufacturer ( °F)6
09 Compliance Statement:System complies with Subcooling Method - Must also pass
metering device verification, next section
G. Metering Device Verification
HERS Rater must independently collect all data in this section. Procedures for the verification of proper metering device operation are specified
in RA3.2.2.6.2
01 Measured Suction Line Temperature (Tsuction) ( °F)34
02 Measured Suction Line Pressure (Psuction) (psig)96
03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital
Gauge or P-T Table using Line G02 ( °F)
30
04 Measured Superheat (Line G01- Line G03) ( °F)4
05 Measured Superheat (Line G04) is between 3 °F and 26 °F
(inclusive)
Passes CEC requirement
06 Measured Superheat (Line G04) is within Manufacturer's
Specifications ( if known)
Yes, documentation to be provided upon request
07 Compliance Statement:Metering device verification passes
H. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
REFRIGERANT CHARGE VERIFICATION CF3R-MCH-25-H
(Page 4 of 4)
Registration Number:
424-P010143661A-000-002-M25019A-M25A
Registration Date/Time: 2025-02-19 13:22:28 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-19 13:23:45
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Angelia Long
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-19
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-19
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number:
424-P010143661A-000-002-M26020A-M26A
Registration Date/Time: 2025-02-14 15:42:13 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:28
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 1 of 5)
CERTIFICATE OF VERIFICATION
Project Name: Bella at Piazza Serena Enforcement Agency: La Quinta, City of
Dwelling Address: 57735 Pasatiempo Court Permit Number: BRES2024-0125
City and Zip Code La Quinta, 92253 Permit Application Date: 2024-03-14
A. System Information
Procedures for verification of High SEER/SEER2 and EER/EER2 Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring
verification must use a separate form.
01 Space Conditioning System Identification or Name HVAC1
02 Space Conditioning System Description of Area Served LIVING 2
03 Efficiency Metric EER2/SEER2
04 Status: SEER/SEER2 Performance Compliance Credit Check Yes
05 Status: EER/EER2 Performance Compliance Credit Check Yes
06 Status: Heat Pump Heating Output Performance Compliance Check No
07 Status: HSPF/HSPF2 Performance Compliance Credit Check No
08 Directory used to certify product performance AHRI
09 AHRI certification number for the installed space conditioning
system from http://www.ahridirectory.org
214287336
10 Does the directory used to certify product performance require a
specific air handler/furnace make and model?
Furnace air-handling unit
11 Does the directory used to certify product performance require a
time delay relay (+TDR)?
Yes
12 Does the directory used to certify product performance require a
TXV (+TXV)?
Yes
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 2 of 5)
Registration Number:
424-P010143661A-000-002-M26020A-M26A
Registration Date/Time: 2025-02-14 15:42:13 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:28
B. Rated Space Conditioning System Equipment Information from Nameplate of the Installed System
The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to
certify product performance in order to demonstrate compliance.
01 02 03 04
Data from Nameplate of Installed System Component
05 06 07 08 09 10
SC System
ID/Name
from CF1R
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 LIVING 2 LIVING 2 AC Coil GOODMAN GSXH50301
0 GOODMAN CP37E34 GOODMAN GM9S96060
3
C. Rated Space Conditioning System Equipment Information from Directory of Certified Product Performance
The data on the nameplate of the installed component shall conform to the data for the component as shown in the Directory used
to certify product performance in order to demonstrate compliance.
01 02 03 04
Data from the Directory used to certify product performance for the rated system
component
05 06 07 08 09 10
SC System
ID/Name on
CF1R
SC System
Description
of Area
Served
Indoor Unit
Name or
Description
of Area
Served
Installed
Indoor Unit
Type
Outdoor
Condenser or
Package Unit -
Installed
Manufacturer
Name
Outdoor
Condenser
or Package
Unit -
Installed
Model
Number
Indoor Unit -
Installed
Manufacturer
Name
Indoor Unit
- Installed
Model
Number
Installed
Furnace
Manufacturer
Name
Installed
Furnace
Model
Number
HVAC1 LIVING 2 LIVING 2 AC Coil GOODMAN GSXH50601
0A Aspen CP61C34+T
DR Aspen GM9S96080
5CUA*
D. Verified Cooling System SEER/SEER2
01 Required minimum SEER/SEER2 15.2
02 Installed SEER/SEER2 15.2
03 Compliance Statement:System Passes SEER/SEER2 Verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent MCH-26 Certificate of Installation
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 3 of 5)
Registration Number:
424-P010143661A-000-002-M26020A-M26A
Registration Date/Time: 2025-02-14 15:42:13 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:28
E. Verified Cooling System EER/EER2
01 Required minimum EER/EER2 12.5
02 Installed EER/EER2 12.5
03 Compliance Statement:System passes EER/EER2 verification
Signature by responsible person on this compliance document certifies that the installed cooling equipment meets or exceeds the required
value listed on the parent MCH-26 Certificate of Installation.
F. Verified Heat Pump Heating Output
This section does not apply to this project.
G. Verified Heat Pump HSPF/HSPF2
This section does not apply to this project.
H. Verified Space Conditioning System Air Handler, Furnace or Fan Coil
01
If a specific air handler, furnace or fan coil is required by the directory used to certify product performance, the responsible person
certifies by signing this compliance document that the installed air handler/furnace matches the equipment specified by the Directory of
Certified Product Performance.
02 Verification Status:Pass - all applicable requirements are met.
03 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
I. Verified Space Conditioning System Time Delay Relay
01
If a Time Delay Relay is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this
compliance document that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of
RA3.4.3.
02 Verification Status:Pass - all applicable requirements are met.
03 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 4 of 5)
Registration Number:
424-P010143661A-000-002-M26020A-M26A
Registration Date/Time: 2025-02-14 15:42:13 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:28
J. Verified Space Conditioning System TXV
01 If a TXV is specified by the Directory of Certified Product Performance, the responsible person certifies by signing this compliance
document that the TXV is properly installed and has been visually verified, including proper placement of the sensing bulb.
02 Verification Status:Pass - all applicable requirements are met.
03 Correction Notes:
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless
otherwise noted in the Verification Status and the Corrections Notes in this table.
K. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
RATED SPACE CONDITIONING SYSTEM
EQUIPMENT VERIFICATION
CF3R-MCH-26-H
(Page 5 of 5)
Registration Number:
424-P010143661A-000-002-M26020A-M26A
Registration Date/Time: 2025-02-14 15:42:13 HERS Provider: CHEERS
CA Building Energy Efficiency Standards
2022 Residential Compliance
Report Version: 2022.0.000
Schema Version: rev 20220101
Report Generated: 2025-02-14 15:43:28
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Steven Bryant
Documentation Author Signature:
Company:
Energy Inspectors Corporation
Date Signed:
2025-02-14
Address:
2570 South Miller Lane
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Las Vegas NV 89117
Phone:
(702) 365-8080
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Verification is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible
rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS
verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3,
and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s)
responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)
approved by the enforcement agency.
5.I understand that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s)
issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary
steps to ensure this requirement is accomplished.
6.I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder
provides to the building owner at occupancy, and I will take the necessary steps to ensure this requirement is accomplished.
BUILDER OR INSTALLER INFORMATION AS SHOWN ON THE CERTIFICATE OF INSTALLATION
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
NP Mechanical, Inc.
Responsible Builder or Installer Name:
Kim Schmitz
CSLB License:
890694
HERS PROVIDER DATA REGISTRY INFORMATION
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
N/A
HERS RATER INFORMATION
HERS Rater Company Name:
Energy Inspectors Corporation
Responsible Rater Name:
Jeremiah Reyes
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
RCN14599
Date Signed:
2025-02-14
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or
related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Scan to Validate
CHEERS REGISTRY
PROJECT STATUS REPORT
CERTIFICATE OF COMPLIANCE (CF1R)
DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS
07/27/2024 CF1R-PRF-01-E Performance Compliance 424-P010143661A-000-000-0000000-0000
CERTIFICATE OF INSTALLATION (CF2R)
DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS
01/07/2025 CF2R-ELC-01-E Electric Ready 424-P010143661A-000-002-C01007A-0000
01/06/2025 CF2R-ENV-01-E Fenestration 424-P010143661A-000-002-E01003A-0000
01/06/2025 CF2R-ENV-03-E Insulation Installation 424-P010143661A-000-002-E03004A-0000
02/14/2025 CF2R-ENV-20a-H Building Leakage 424-P010143661A-000-002-E20021A-0000
01/06/2025 CF2R-ENV-21-H QII 424-P010143661A-000-002-E21005A-0000
01/06/2025 CF2R-ENV-22-H QII 424-P010143661A-000-002-E22006A-0000
01/07/2025 CF2R-LTG-01-E Lighting 424-P010143661A-000-002-L01008A-0000
02/04/2025 CF2R-MCH-01a-E HVAC, Ducts and Fans 424-P010143661A-000-002-M01009A-0000
02/04/2025 CF2R-MCH-27a-H Mechanical Ventilation 424-P010143661A-000-002-M27010A-0000
02/14/2025 CF2R-MCH-32-H Local Mechanical Exhaust 424-P010143661A-000-002-M32022A-0000
11/07/2024 CF2R-PLB-02-E Single Family Hot Water 424-P010143661A-000-002-B02001A-0000
01/02/2025 CF2R-PVB-01-E Photovoltaic Systems 424-P010143661A-000-002-P01002A-0000
PROJECT SUMMARY
Project Name:Ph 019 (BO) _ Lot 094
Address:57735 Pasatiempo Court
City, State, Zip:La Quinta, CA 92253
Building Department:La Quinta, City of
Permit Number: BRES2024-0125
Building Energy Code:2022 Standards
ENERGY CODE
COMPLIANCE COMPLETE
HERS VERIFIABLE
MEASURES
COMPLETE
NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using
information that has been uploaded to that registration platform by third parties that are not affiliated or related to
CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the
information contained in this certificate. Page 1 of 3
- continued on next page -
Scan to Validate
CHEERS REGISTRY
PROJECT STATUS REPORT
CERTIFICATE OF INSTALLATION (CF2R)
DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS
HVAC1
02/04/2025 CF2R-MCH-25b-H Refrigerant Charge 424-P010143661A-000-002-M25017A-0000
02/04/2025 CF2R-MCH-25b-H Refrigerant Charge 424-P010143661A-000-002-M25019A-0000
02/04/2025 CF2R-MCH-26-H High SEER & EER 424-P010143661A-000-002-M26020A-0000
02/04/2025 CF2R-MCH-26-H High SEER & EER 424-P010143661A-000-002-M26018A-0000
living 1
02/04/2025 CF2R-MCH-20c-H Duct Leakage 424-P010143661A-000-002-M20011A-0000
02/04/2025 CF2R-MCH-22a-H Fan Efficacy 424-P010143661A-000-002-M22013A-0000
02/04/2025 CF2R-MCH-23a-H Airflow Rate 424-P010143661A-000-002-M23012A-0000
LIVING 2
02/04/2025 CF2R-MCH-20c-H Duct Leakage 424-P010143661A-000-002-M20014A-0000
02/04/2025 CF2R-MCH-22a-H Fan Efficacy 424-P010143661A-000-002-M22016A-0000
02/04/2025 CF2R-MCH-23a-H Airflow Rate 424-P010143661A-000-002-M23015A-0000
CERTIFICATE OF VERIFICATION (CF3R)
DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS
02/14/2025 CF3R-ENV-20a-H Building Leakage 424-P010143661A-000-002-E20021A-
E20A
02/18/2025 CF3R-ENV-21-H QII 424-P010143661A-000-002-E21005A-
E21A
02/18/2025 CF3R-ENV-22-H QII 424-P010143661A-000-002-E22006A-
E22A
02/19/2025 CF3R-MCH-27a-H Mechanical Ventilation 424-P010143661A-000-002-M27010A-
M27A
02/14/2025 CF3R-MCH-32-H Local Mechanical Exhaust 424-P010143661A-000-002-M32022A-
M32A
NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using
information that has been uploaded to that registration platform by third parties that are not affiliated or related to
CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the
information contained in this certificate. Page 2 of 3
- continued on next page -
Scan to Validate
CHEERS REGISTRY
PROJECT STATUS REPORT
CERTIFICATE OF VERIFICATION (CF3R)
DATE DOCUMENT TITLE REGISTRATION NUMBER STATUS
HVAC1
02/18/2025 CF3R-MCH-25b-H Refrigerant Charge 424-P010143661A-000-002-M25017A-
M25A
02/19/2025 CF3R-MCH-25b-H Refrigerant Charge 424-P010143661A-000-002-M25019A-
M25A
02/19/2025 CF3R-MCH-26-H High SEER & EER 424-P010143661A-000-002-M26018A-
M26A
02/14/2025 CF3R-MCH-26-H High SEER & EER 424-P010143661A-000-002-M26020A-
M26A
living 1
02/18/2025 CF3R-MCH-20c-H Duct Leakage 424-P010143661A-000-002-M20011A-
M20A
02/18/2025 CF3R-MCH-22a-H Fan Efficacy 424-P010143661A-000-002-M22013A-
M22A
02/18/2025 CF3R-MCH-23a-H Airflow Rate 424-P010143661A-000-002-M23012A-
M23A
LIVING 2
02/18/2025 CF3R-MCH-20c-H Duct Leakage 424-P010143661A-000-002-M20014A-
M20A
02/18/2025 CF3R-MCH-22a-H Fan Efficacy 424-P010143661A-000-002-M22016A-
M22A
02/18/2025 CF3R-MCH-23a-H Airflow Rate 424-P010143661A-000-002-M23015A-
M23A
NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using
information that has been uploaded to that registration platform by third parties that are not affiliated or related to