BRES2023-0210DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Permit Number:
Property Address
APN:
Legal Description
Property Zoning:
Valuation:
BUILDING PERMIT
eca Qa�&a
CALIFORNIA
Building Residential
BRES2023-0210
53293 VIA BELLAGIO
777160026
Lot 309 MB 327/56 TR 29894-2
RL, 309
$587,394.20
Owner:
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 07/19/2023
ISSUED DATE: 10/30/2023
Via Bellaigo LLC
38-747 Nopales Rd, Palm Desert, CA 92211
Applicant: George Camarena Jr
78206 VARNER ROAD STE D #248, PALM
DESERT, CA 92211
Contractor: Fedderly Associates / 762889
38-747 NOPALES ROAD, PALM DESERT, CA
92211-1168
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.Ieginfo.ca.gov/calaw.htm1.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 4/10/25 2:29 pm Page 1 of 7
BUILDING PERMIT
Permit Type: Building Residential
Permit Number: BRES2023-0210
Property Address: 53293 VIA BELLAGIO
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
Printed: 4/10/25 2:29 pm Page 2 of 7
Permit Type
Building Residential
BUILDING PERMIT
Permit Number:
Property Address
BRES2023-0210
53293 VIA BELLAGIO
VIA BELLAIGO/ 9,898SF 2-STORY SINGLE FAMILY DWELLING WITH ATTACHED GUEST SUITE [VB/RES-3/CLASS A-FR/13D] THIS PERT
DOES NOT INCLUDE PV SYSTEM, POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH OR SIMILAR EXTERIOR STRUCTURES. 2022
CALIFORNIA BUILDING CODES.
REVISION 1
REVISED ENERGY TO REFLECT FENESTRATION ON SITE. 2022 CALIFORNIA BUILDING CODES.
instruction Deta
Residential Work Type Dwelling - Single Family
Conditioned Square
6628
Garage Square
1787
Detached
Footage
Footage
Patio Square Footage
1483
Fire Sprinkler Square
9898
Construction Type
V-B
Footage
Code Edition
2022
Number of Floors
2
Number of Bedrooms
5
Number of Units
1
Building/Unit
R-3: 1 & 2 Family
Grading Required?
Yes, New Dwelling
Occupancy
Dwellings
Classification(s)
Dwelling Units per
1.76
Number of Flag or
0
New Electrical Square
9898
Acre (CVMSHCP)
Light Pole(s)?
Footage
Number of Forced Air
4
Number of Ventilation
8
Number of Exhaust
1
Furnace(s)
Fan(s)
Hood(s)
Number of Plumbing
46
Number of Water
2
Water System Install
Yes
Fixtures/Traps
Heater(s)
or Alteration?
Number of Gas
1
Sewer Connection?
Yes
Zoning
RL
Outlet(s)
General Plan LDR City Limits Within La Quinta Limits Subdivision Name TR 29894-2
Lot Number 309 Centerlines 100278, 100591 Lot Size 3328.18
Legal Description Lot 309 MB 327/56 TR
29894-2
Type Group Sq Ft Value
Printed: 4/10/25 2:29 pm Page 3 of 7
Permit Type
Building Residential
BUILDING PERMIT
Permit Number:
Property Address
BRES2023-0210
53293 VIA BELLAGIO
Invoice No.
Fee
Fee Amount
Amount Paid
INV-00001978
DIF - CIVIC CENTER
$1,230.00
$1,230.00
RECORDS MANAGEMENT FEE - MAJOR
$22.00
$22.00
RESIDENTIAL, FIRST 1,000SF PC
$57.77
$57.77
WATER HEATER/VENT PC
$17.50
$17.50
RESIDENTIAL, FIRST 1,000SF
$175.07
$175.07
BUILDING SEWER PC
$20.42
$20.42
BUILDING SEWER
$29.18
$29.18
TECHNOLOGY ENHANCEMENT FEE
$8.00
$8.00
DIF - TRANSPORTATION
$4,009.00
$4,009.00
EXHAUST HOOD PC
$5.84
$5.84
DIF - MAINTENANCE FACILITIES
$313.00
$313.00
DIF - COMMUNITY CULTURAL
$956.00
$956.00
ART IN PUBLIC PLACES - RESIDENTIAL
$968.48
$968.48
FIXTURE/TRAP PC
$671.14
$671.14
FURNACE PC
$116.72
$116.72
RESIDENTIAL, EA ADDITIONAL 1,000SF
$133.92
$133.92
DIF - PARK IMPROVEMENTS
$2,106.00
$2,106.00
FURNACE
$175.08
$175.08
BSAS SB1473 FEE
$24.00
$24.00
DIF - FIRE PROTECTION
$369.00
$369.00
RESIDENTIAL - CUSTOM HOME >7KSF PC
$218.84
$218.84
NEW CONSTRUCTION PERMIT 2022
$3,934.35
$3,934.35
WATER SYSTEM INST/ALT/REP
$14.59
$14.59
FIXTURE/TRAP
$671.14
$671.14
WATER HEATER/VENT
$29.18
$29.18
NEW CONSTRUCTION PLAN CHECK 2022
$2,496.88
$2,496.88
GAS SYSTEM, 1-4 OUTLETS PC
$29.18
$29.18
VENT FAN PC
$46.72
$46.72
TUMF 2023 - SINGLE FAMILY DWELLING
$2,550.00
$2,550.00
SMI - RESIDENTIAL
$76.36
$76.36
VENT FAN
$116.72
$116.72
DIF - LIBRARY
$397.00
$397.00
WATER SYSTEM INST/ALT/REP PC
$14.59
$14.59
RESIDENTIAL - CUSTOM HOME >7KSF
$43.77
$43.77
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2023 UPDATE
$1,625.00
$1,625.00
GAS SYSTEM, 1-4 OUTLETS
$14.59
$14.59
EXHAUST HOOD
$14.59
$14.59
RESIDENTIAL, EA ADDITIONAL 1,000SF PC
$55.17
$55.17
Total for Invoice lNV-00001978
$23,756.79
$23,756.79
INV-00004534
Building Staff Time
$131.25
$131.25
Credit Card Convenience Fee
$3.28
$3.28
Total for Invoice lNV-00004534
$134.53
$134.53
INV-00006573
Partial Inspection Fee
$87.53
$87.53
Total for Invoice lNV-00006573
$87.53
$87.53
INV-00007021
Partial Inspection Fee
$87.53
$87.53
Tnfal fnr lnvnlrp INV-1 AAM21
$87.53
$87.53
Printed: 4/10/25 2:29 pm Page 4 of 7
BUILDING PERMIT
Permit Type: Building Residential
Permit Number: BRES2023-0210
Property Address: 53293 VIA BELLAGIO
INV-00007126 Partial Inspection Fee $87.53 $87.53
Total for Invoice lNV-00007126 $87.53 $87.53
INV-00010777 Re -Inspection Fee $87.53 $87.53
Total for Invoice lNV-00010777 $87.53 $87.53
Grand Total for Permit $24,241.44 $249241.44
Workflow Step / Action Name Action Type Start Date End Date
Deferred Submittals v.1
04/09/2024
8:03
---------------------------------------------------------------------------------------------------------------------------------------
Linked Solar Permit v.1
Create Sub Permit
---------------------------------------------------------------------------------------------------------------------------------------
Linked Fire Sprinkler Permit v.1
Create Sub Permit
04/09/2024
8:03
10/31/2024 15:16
Revisions v.1
02/08/2024
0:00
02/15/2024 15:42
---------------------------------------------------------------------------------------------------------------------------------------
Building Revision Review v.1
Receive Submittal
02/08/2024
0:00
02/15/2024 15:42
---------------------------------------------------------------------------------------------------------------------------------------
Building Revision Review v.1
Receive Submittal
04/23/2024
0:00
05/08/2024 8:56
---------------------------------------------------------------------------------------------------------------------------------------
Building Revision Review v.2
Receive Submittal
05/08/2024
0:00
Plan Check v.1
08/30/2023
0:00
10/27/2023 7:49
---------------------------------------------------------------------------------------------------------------------------------------
Building Major Review v.1
Receive Submittal
08/30/2023
0:00
10/11/2023 8:49
---------------------------------------------------------------------------------------------------------------------------------------
Building Major Review v.2
Receive Submittal
10/11/2023
0:00
10/27/2023 7:49
Permit Issuance v.1
10/27/2023
7:51
12/19/2023 8:47
---------------------------------------------------------------------------------------------------------------------------------------
Contractor / Owner -Builder Information v.1
Generic Action
10/27/2023 7:52
---------------------------------------------------------------------------------------------------------------------------------------
Verify & Invoice Fees v.1
Generic Action
10/27/2023 7:52
------------------------------------------ -- -- -- -- -- --
Ready to Issue v.1
-- -- -- -- -- -- -------------------------------------------------
Generic Action
-----
10/30/2023 15:50
-- -- -- -- - ------------------------------ -- -- -- -- --
Verify Fee Payment & Issue Permit v.1
-- -- -- -- -- -- -- -- -------------------------
Generic Action
-- --
-- -- -- -- -- --
10/30/2023 15:50
---------------------------------------------------------------
Print, Attach, and Email Building Permit v.1
------------------------------------------------
Create Report
10/30/2023
------
15:50
----------------- -
12/19/2023 8:47
Inspections - Do Not Pour Concrete Until Approved v.1
12/06/2023
0:00
----------------------------------------------------------------------------------------------------------------------------------------
Setbacks v.1
Inspection
----------------------------------------------------------------------------------------------------------------------------------------
Underground Plumbing v.1
Inspection
12/06/2023
0:00
12/07/2023 15:55
----------------------------------------------------------------------------------------------------------------------------------------
Water Line v.1
Inspection
----------------------------------------------------------------------------------------------------------------------------------------
Template Footing v.1
Inspection
12/06/2023
0:00
12/07/2023 15:30
----------------------------------------------------------------------------------------------------------------------------------------
Footing v.1
Inspection
12/20/2023
0:00
12/21/2023 10:55
---------------------------------------------------------------------------------------------------------
Slab v.1
Inspection
-------------
12/28/2023
0:00
-- -----------
01/02/2024 9:43
Inspections - Cover No Work Until Approved v.1
02/05/2024
0:00
---------------------------------------------------------------------------------------------------------------------------------------
Roof Nail v.1
Inspection
02/05/2024
0:00
02/06/2024 9:31
---------------------------------------------------------------------------------------------------------------------------------------
Roof Nail v.2
Inspection
03/28/2024
0:00
03/29/2024 10:44
---------------------------------------------------------------------------------------------------------------------------------------
Roof Nail v.3
Inspection
05/01/2024
0:00
05/01/2024 15:49
---------------------------------------------------------------------------------------------------------------------------------------
Floor Nail v.1
Inspection
02/13/2024
7:39
02/13/2024 12:16
---------------------------------------------------------------------------------------------------------------------------------------
Roof Drains v.1
Inspection
05/15/2024
14:21
05/15/2024 14:22
--------------------------------------------------------------------------------
Okay to Wrap v.1
Inspection
--------------------------------------
05/06/2024
0:00
05/07/2024 14:00
---------------------------------------------------------------------------------------------------------------------------------------
Framing v.1
Inspection
04/30/2024
0:00
05/01/2024 9:49
---------------------------------------------------------------------------------------------------------------------------------------
Framing v.2
Inspection
05/07/2024
0:00
05/08/2024 11:22
---------------------------------------------------------------------------------------------------------------------------------------
Framing v.3
Inspection
05/09/2024
0:00
05/13/2024 12:38
---------------------------------------------------------------------------------------------------------------------------------------
Framing v.4
Inspection
05/20/2024
0:00
05/21/2024 11:58
---------------------------------------------------------------------------------------------------------------------------------------
Rough Electrical v.1
Inspection
05/20/2024
0:00
05/21/2024 14:02
-----------------------------------------------------------------------
Rough Mechanical v.1
Inspection
--------------------------------------
05/20/2024
0:00
05/21/2024 14:02
Printed: 4/10/25 2:29 pm Page 5 of 7
BUILDING PERMIT
Permit Type: Building Residential
Permit Number: BRES2023-0210
Property Address: 53293 VIA BELLAGIO
Rough Plumbing v.1
Inspection
05/20/2024
0:00
05/21/2024
14:02
----------------------------------------------------------------------------------------------------------------------------------------
Rough Fire Clearance v.1
Generic Action
----------------------------------------------------------------------------------------------------------------------------------------
Shower Pan v.1
Inspection
05/14/2024
0:00
05/16/2024
14:18
----------------------------------------------------------------------------------------------------------------------------------------
Insulation v.1
Inspection
05/15/2024
0:00
05/16/2024
14:21
----------------------------------------------------------------------------------------------------------------------------------------
Insulation v.2
Inspection
05/31/2024
0:00
06/03/2024
12:28
----------------------------------------------------------------------------------------------------------------------------------------
Insulation v.3
Inspection
06/05/2024
0:00
06/06/2024
10:45
----------------------------------------------------------------------------------------------------------------------------------------
Insulation v.4
Inspection
06/07/2024
0:00
06/10/2024
10:13
----------------------------------------------------------------------------------------------------------------------------------------
Drywall Nail v.1
Inspection
06/06/2024
0:00
06/07/2024
9:15
----------------------------------------------------------------------------------------------------------------------------------------
Drywall Nail v.2
Inspection
06/11/2024
0:00
06/12/2024
14:58
----------------------------------------------------------------------------------------------------------------------------------------
Exterior Lath v.1
Inspection
06/11/2024
0:00
06/12/2024
14:58
----------------------------------------------------------------------------------------------------------------------------------------
Gas Test v.1
Inspection
06/18/2024
0:00
06/19/2024
11:08
----------------------------------------------------------------------------------------------------------------------------------------
Sewer Connection v.1
Inspection
02/21/2024
0:00
02/22/2024
9:59
Inspections - Masonry v.1
04/23/2024
0:00
04/24/2024
11:15
----------------------------------------------------------------------------------------------------------------------------------------
Footing v.1
Inspection
04/23/2024
0:00
04/24/2024
11:15
Inspections - Electrical for Meter Release v.1
11/06/2023
0:00
09/12/2024
13:23
----------------------------------------------------------------------------------------------------------------------------------------
Temporary Power v.1
Inspection
11/06/2023
0:00
11/07/2023
9:22
----------------------------------------------------------------------------------------------------------------------------------------
Temp Use of Permanent Power v.1
Inspection
09/11/2024
0:00
09/12/2024
13:23
Inspections - Final v.1
01/24/2024
0:00
---------------------------------------------------------------------------
Final Fire v.1
..................
Inspection
10/22/2024
14:02
10/31/2024
15:16
............................................................................................................................
Final Building v.1
Inspection
01/24/2024
0:00
..........
01/25/2024
11:19
--------------------------
Final Building v.2
----------------------
Inspection
-
11/04/2024
...
0:00
----------
11/05/2024
11:27
------------------------------------------------
Final Building v.3
--------------------
Inspection
11/19/2024
0:00
-----------
11/20/2024
13:28
-----------------------------------------------
Final Building v.4
Inspection
--------
11/25/2024
0:00
---------
11/26/2024
17:30
--------------------------------------------
Final Building v.5
Inspection
--------
01/22/2025
16:14
01/22/2025
---
16:17
------------------------------------------
Final Planning/Zoning v.1
Inspection
--------
--
Certificate of Occupancy v.1
01/22/2025
16:22
01/22/2025
16:22
----------------------------------------------------------------------------------------------------------------------------------------
Certificate of Occupancy v.1
Create Report
01/22/2025
16:22
01/22/2025
16:22
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Printed: 4/10/25 2:29 pm Page 6 of 7
BUILDING PERMIT
Permit Type: Building Residential
Permit Number: BRES2023-0210
Property Address: 53293 VIA BELLAGIO
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the buildina official.
Printed: 4/10/25 2:29 pm Page 7 of 7
T4t!t 4 4Q"
DESIGN & DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011 BRES2023-0210
STREET ADDRESS OF JOB: 53293 VIA BELLAGIO
APN: 777160026
DESCRIPTION OF WORK: NEW SINGLE FAMILY RESIDENCE
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE COM PL IANCE
BY:Deisy Mendez DATE: 08/02/2023
SQUARE FOOTAGE: LIVABLE AREA 6,628SF & NON -LIVABLE AREA 3,270SF FOR A TOTAL
AREA OF 9898SF
OWNER'S NAME: Via Bellaigo LLC
For questions regarding this letter, please contact:
City of La Quinta Permit Center
(760) 777-7125
Coachella Valley Unified School District
87-225 Church St
Thermal, CA 92274
(760) 848-1880
Desert Sands Unified School District
47-950 Dune Palms Road
Lo Quinta, CA 92253
(760) 771-8515
Please note: This letter verifies conditioned square footage. Please call your School
District to verify school fees, requirement for cashier's check or money order and hours
of operation.
DESIGN & DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
DATE: AUGUST 02, 2023
STATUS: FIRST REVIEW
PLAN CHECKED BY: DEISY MENDEZ/INTERWEST
TELEPHONE NUMBER: (760) 777-7002
ADDRESS: 53293 VIA BELLAGIO
DESCRIPTION: SINGLE FAMILY RESIDENCE
APPLICANT: FEDDERLY & ASSOCIATES
PLAN CHECK #: BRES2023-0210
This submittal has been checked for compliance with the 2022 California Residential, Mechanical, Electrical, Plumbing,
Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT:
The following items are being returned to you for
correction:
1ST REVIEW PLAN SET
1ST REVIEW CORRECTION LIST
BUILDING DEPARTMENT STAFF:
DO NOT accept any resubmittal unless ALL of the
following items are included:
-RESPONSE LIST TO CORRECTION LISTS
-REVISED PLAN SET
-REVISED DOCUMENTS (AS NECESSARY)
-TRUSS CALCULATIONS
-SOILS FOUNDATION LETTER
-SCHOOL FEE RECEIPT
-DEBRIS MANAGEMENT PLAN (BURRTEC)
-GRANT DEED
-PW APPROVAL (REVIEW PENDING)
-FIRE APPROVAL (REVIEW PENDING)
- PLANNING APPROVAL (COMMENTS PAGE 2)
INSTRUCTIONS TO APPLICANT:
1) Provide a response to each comment on the following pages, noting specifically where the correction can be found.
Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note
specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are
appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise original Plans and/or Calculations as
necessary.
3) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall
be electronically signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by
that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section
5536. Resubmittals will not be accepted with signatures missing.
Residential Plan Check Correction List Page 1 of 2
SECTION A - GENERAL
1) The City of La Quinta has elected to use Interwest Consulting for plan review of your project. In addition to the
comments provided by the City of La Quinta within this correction list please see the attached outside consultant
review comments. See Complete Review Comments Attached, for resubmittal please include a separate response
sheet for each set of review comments.
2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone
number and electronic signature. If the preparer is a licensed architect or engineer, all documents prepared by that
licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536.
Resubmittals will not be accepted with signatures missing.
3) Provide Planning Division approval for this Project. Please contact Siji Fernandez directly at (760) 777-7086 with
questions regarding the following comment(s):
a) SUBMIT A FINAL LANDSCAPE PLAN TO CVWD AND PROVIDE APPROVED PLANS.
4) Provide Riverside County Office of the Fire Marshall approval of this project. Contact Kohl Hetrick directly at (760) 777-
7074 with questions regarding the following comment(s):
a) PENDING REVIEW —REACH OUT TO FIRE DEPARTMENT FOR STATUS UPDATE OR LOGIN TO PORTAL FOR STATUS
5) Provide written evidence of Public Works Division approval of this Project. Contact Amy Yu directly at (760) 777-7047.
a) PENDING REVIEW —REACH OUT TO PW DEPARTMENT FOR STATUS UPDATE OR LOGIN TO PORTAL FOR STATUS
6) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 65% of
the construction materials from landfill for the project. Contact the District Environmental Coordinator directly at (760)
674-1026 for free assistance with the preparation of this plan.
SECTION B — MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as
necessary and provide written response, noting where correction can be found.
2) Provide contractor information to complete building permit application form.
3) Provide proof of payment of school fees. While not required for resubmittal, this administrative item must be
addressed prior to issuance of building permit.
4) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation will be
performed when Plans are complete.
END CITY REVIEW CORRECTION LIST - CORRECTION LIST CONTINUED BY INTERWEST CONSULTING GROUP ATTACHED
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List Page 2 of 2
July 30, 2023
CITY OF LA QUINTA - FIRST REVIEW
Permit No: BRES2023-0210
Interwest No.: LAQ23-0109
Non -Structural: 4-hours
Structural: 2-hours
City of La Quinta
Building Department
78-495 Calle Tampico
La Quinta, CA 92253
Plan Review: New SFR
Address: Lot #309
0
r"T
INTERWEST
A SAFEbuiflt COMPANY
Interwest Consulting Group has completed a first code compliance review of the following documents on behalf of
the City of La Quinta:
1. Drawings: PDF copy of following:
a. T1 through T3 dated 7/19/2023 by Fedderly-Camarena Design, Inc.
b. G1 through G2 dated 7/19/2023 by ESSI Engineering.
C. A1.0 through A9.3 dated 7/19/2023 by Fedderly-Camarena Design, Inc.
d. F1.0 through F2.0 dated 7/19/2023 by Fedderly-Camarena Design, Inc.
e. AD1 through AD8 dated 7/19/2023 by Fedderly-Camarena Design, Inc.
f. GN through HFX-3 dated 7/14/2023 by RA Structural Engineering.
g. E1.0 through E3.0 dated 7/19/2023 by Fedderly-Camarena Design, Inc.
h M1.0 through M3.2 dated NA by Scott Design and Title 24.
i. P1.0 through P4.0 dated 7/6/2023 by EGD Designs.
j. L1.0 dated 7/13/2023
2. Structural Calculations: PDF copy dated 6/30/2023 by RA Structural Engineering.
3. Energy Compliance Documentation: PDF copy dated 6/16/2023 by Scott Design and Title 24 Inc.
4. Geotechnical Investigation: PDF copy dated 4/21/2023 by Sladden Engineering.
The applicable provisions of the 2022 California Building Standards Code were used as the basis of this review.
Plan review comments follow on the attached list.
Please submit an itemized response letter and complete and revised documents with directly to city of La Quinta
Building and Safety Department.
Sincerely,
INTERWEST CONSULTING GROUP
Eric Corral
Plans Examiner
1500 S. Haven Ave I Suite 220
Ontario, CA 91761
909.295-3142 INTERWESTORP.COM
New SFR
Lot #309
7130123
PROJECT DATA:
City of La Quints - First Review
Interwest Project No. LAQ23-0109
Permit App: BRES2023-0210
Page 2 of 4
Occupancy Group:
Area (sq. ft.):
R3
U
6,628
3,270
Total Area:
9,898
Building Height:
26'
Building Stories:
2
Type of Construction:
VB
Occupant Load:
NA
Sprinklered:
Y
Valuation:
$2,400,000
Wildland Urban Interface
(WUI) Fire Area?
TBD-See comments
Flood Zone:
AE
Risk Category:
II
Site Class (seismic):
D
Seismic Design Category:
D
Special Wind Region:
TBD-See comments
Snow Loads:
TBD-See comments
GENERAL COMMENTS:
G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following
comments reference the 2022 California Building Standards Code as amended by the authority having
jurisdiction unless otherwise noted.
G2. Please respond in writing to each plan review comment by marking this comment list or creating a response
letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the
following should be included with each plan review response:
• Page / sheet number(s), detail / specification number(s), etc., and include all applicable code
section(s).
• Briefly explain in writing how the design is intended to comply with the applicable code sections.
• Please provide a narrative of revisions made outside the plan review comments.
Complete and clear responses will expedite the re -check of this project.
G3. Please be sure to include on the re -submittal the architect's and /or engineer's stamp, signature, date of
signature, and registration number on all sheets of plans depicting structural designed elements and cover
sheets of calculations. CBPC 5536.1 and 6735.
INTERWEST
New SFR City of La Quints - First Review
Lot #309 Interwest Project No. LAQ23-0109
7130123 Permit App: BRES2023-0210
Page 3 of 4
PLAN REVIEW COMMENTS:
BUILDING AND LIFE SAFETY: [Eric Corral; ecorral@interwestgrp.com; 909.725.68291
Al. All sheets of the plans are required to be signed by the California licensed architect or engineer
responsible for the plan preparation. Please include the California license number, seal, date of license
expiration and the date the plans are signed. [§ 5536.1, 6735 California Business and Profession Code]
A2. Designer to sign/date sheets they are responsible for preparing.
A3. Update all notes on the plans to be consistent with the 2022 CRC. (Sheet T-1 Building Department
Notes)
A4. Provide the project address on each sheet of the plans. [§ R106.1.1 CRC]
AS. Provide a letter from the soils engineer confirming that the foundation plans, retaining walls, slope
setbacks, grading plans and specifications have been reviewed and that it has been determined that the
recommendations in the soil report are properly incorporated in the plans. [§ R401.4 CRC]
A6. Soils engineer information, stamp, and signature required on the first sheet of precise grading plans.
A7. Aging -in -place design and fall prevention. Newly constructed dwellings subject to the requirements of
this code shall be designed and constructed in accordance with Sections R327.1.1 through R327.1.4.
A8. Please verify if the site is located in the WUTA (Wildland-Urban Interface Fire Area also known as
Chapter 7A) if so, the construction is subject to Section R337. Please note on the coversheet and provide
the appropriate construction provisions throughout the plans. Additional comments may occur.
ENERGY COMPLIANCE:
Electrical Compliance: [Eric Corral; ecorral@interwestgrp.com; 909.725.6829]
EE1. All single-family residences that include one or two dwelling units shall be ESS ready or install an ESS system.
[CEnC 150.0(s)] Provide the following:
a) A minimum of four branch circuits shall be identified and have their source of supply collocated at a single
panelboard suitable to be supplied by the ESS. At least one circuit shall supply the refrigerator, one lighting
circuit shall be located near the primary egress and at least one circuit shall supply a sleeping room receptacle
outlet.
b) Sufficient space shall be reserved to allow future installation of a system isolation equipment/transfer
switch within 3 feet of the main panelboard. Raceways shall be installed between the panelboard and the
system isolation equipment/transfer switch location to allow the connection of backup power source.
c) The main panelboard shall have a minimum busbar rating of 225 amps, and
d1) ESS ready interconnection equipment with a minimum backed -up capacity of 60 amps and a
minimum of four ESS-supplied branch circuits, or
INTERWEST
New SFR City of La Quints - First Review
Lot #309 Interwest Project No. LAQ23-0109
7130123 Permit App: BRES2023-0210
Page 4 of 4
d2) A dedicated raceway from the main service to a panelboard (subpanel) that supplies the branch
circuits in CEnC 150.0(s)(2). All branch circuits are permitted to be supplied by the main service panel
prior to the installation of an ESS. The trade size of the raceway shall be not less than 1 inch. The
panelboard that supplies the branch circuits (subpanel) must be labeled "Subpanel shall include all
backed up load circuits."
STRUCTURAL: [Eric Corral; ecorral@interwestgrp.com; 909.725.6829]
S1. Update code references throughout calculations to current 2022 codes. (sheet 261)
S2. Roof trusses may not be deferred without written permission from the Building Department via a
completed deferred truss submittal form. Unless a completed form is provided, truss drawings and
calculations must be provided no later than the second submittal.
S3. Provide truss plans, roof and floor, for all portions of the proposed structure(s). Plans shall include design
for each individual truss, an overall truss layout plan and erection details. Plans shall be stamped, signed and
dated by an engineer registered in the State of California. (R802.10.1 CRC, 107.3.4.1 CBC)
S4. Truss plans shall be submitted to the engineer of record for review prior to submittal to the Building
Department. The engineer of record shall provide a note on the truss plans or a shop drawing approval
stamp stating that the truss plans are in general conformance with the design of the building. The plans
submitted to the Building Department shall contain no red line revisions or corrections to the truss package.
(R106.1 CRC)
Please contact the listed reviewers between 9:00 A.M. and 4:00 P.M., M-F, with any questions.
[END]
INTERWEST
Coachella Valley Unified School District
87-225 Church St., Thermal, CA 92274
(760) 848-1073 francine.solis@cvusd.us
This Box For District Use Only
DF.VF,T,OPFR FF,FS PATD
AREA: COUNTY OF RIVERSIDE
AMOUNT $31,748.12
LEVEL ONE AMOUNI :
1,PVF1, TWO AMOUNT:
MITIGATION AMOUNT:
COMM/IND AMOUNT:
$31,748.12
--------------
---------------
I ------------
DATE:
RECEIPT:
CHECK #:
INITIALS
10/20/2023
214030
0009704746
FS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Via Bellaigo LLC
Date: October 20, 2023
Owner's Name: Via Bellaigo LLC Phone No. (760) 383-8122
Project Address: 53293 VIA BELLAGIO
La Quinta, CA 92253
Project Description: New Single Family Residence
APN: 777160026
Type of Development:
Tract #:
Residential XX
Commercial
Lot #'s:
Total Square Feet of Building Area: 6,628 Square Feet
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: / 9 • ZO - Z,3 Signature:
;V'BEEN
SCHOOL DISTRICT'S REQUIREMENTS FOR T E ABOVE PROJECT HA OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project
17620 65995 Approval
Number of Sq.Ft. 6,628
Amount per Sq.Ft. $4.79
Amount Collected $31,748.12
Building Permit Application Completed: Yes/No
By: Francine A. Solis, Facilities Office Technician
Certificate issued by: Francine A. Solis, Facilities Office Technician
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees,
mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 or the Government code and
other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements
as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of
Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined
by the School Dislrict, and up to three (3) such extensions may be granted.
\4V:u/mvdocs/dc%I'cc0ficate of compliance forin updaled 3 2007 11/2010
Building Permit Number:
Project Description: SFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Datel 9/21/2023
Job Site Address) 53293 Via Bellagio
Owner's Namel Lot 309 Via bellagio LLC
Number, Street, or PO Box1 78206 Varner Rd Ste D #248
City, State, Postal Codel Palm Desert, CA. 92211
Owner's Phone Number 760-773-5205
Owner's E-Mail Address I LanceF Fedderly.com
Project Manager's Namel Jose Carlos Preciado
Project Manager's Phone Number 760-702-9282
Project Manager's E-mail Address I jose(gpfedderly.com
Builder / Contractor Fedderly & Associates
Number, Street or PO Box 38747 Nopales Rd
City, State, Postal Code Palm Desert, CA. 92211
Project Square Footage 24,684 sq ft
City Approval By
Date of City Approval
Materials To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse*
*Describe Items
Renado Gouldlock-DE
4��
Tons
95.00 Not recyclable
0,00 Recyclable
0.00 Recyclable
3,00 Recyclable
0.00 Recyclable
96.00 Recyclable
12.75 Recyclable
0.00 Recyclable
Totals: Recycle Trash
185.3 1 95.0
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
28.00 Recyclable
0.00 Recyclable
2.25 Recyclable
3.25 Recyclable
40.00 Recyclable
0.00 Recyclable
Projected Diversion:
66.10%
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted
from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials
generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is
issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition
project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the
name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered
to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If
self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer station.
Owner / Developer / Project Manager / Superintendant Date
CAL FIRE - RIVERSIDE UNIT
RIVERSIDE COUNTY FIRE DEPARTMENT �Cv
BILL WEISER - FIRE CHIEF
OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
October 26, 2023
FEDDERLY & ASSOCIATES
78206 VARNER ROAD STE D #248
PALM DESERT, CA 92211
george@fedderly-camarenadesign.com
Re: Residential Fire Access & Water / ESS Plan Review — LOT 39 VIA BELLAGIO LLC RES
BRES2023-0210 (53293 VIA BELLAGIO LA QUINTA, CA 92253)
The plans you submitted for the above referenced project have been reviewed by Riverside County Fire
Department - Office of the Fire Marshal personnel and are approved with the following conditions.
1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to
their background shall be displayed on the structure and viewable from the roadway or posted at the
driveway entrance and maintained visible.
2) Vehicle Gates/barricades restricting fire access to the structure are required to be provided with
KNOX emergency access. (CFC 503.6)
3) The proposed structure requires a fire flow of 1,250 gallons per minute from a single hydrant located
within 600-feet of all exterior portions of the structure. (CFC 507.5.1 & APPENDIX B)
4) Public/Private fire hydrants located in front of the property shall be provided with a minimum 3-feet
radius around the hydrant of clearance of any obstructions, including vegetation.
5) Dwelling Units shall maintain a minimum 3-feet clear width Egress Court from emergency escape
windows and doors of sleeping rooms and shall deposit to the front of the property or public way.
These courts shall be traversable pathways, free of obstructions and landscaping intrusions. (Ref.
CBC 1029.2 / CRC R311.1)
6) Energy Storage Systems shall comply with CFC 1206.11.
a. Fire Detection - Areas shall be protected by smoke alarms. A listed heat detector shall be installed
in locations within dwelling units and attached garages where smoke alarms cannot be installed
based on their listing.
b. Protection from Impact — ESS installed in a location subject to vehicle damage shall be protected
by approved barriers.
c. Operating Temperatures — ESS system manuals shall be consulted. Compliance with the
maximum operating ambient temperatures shall be complied with. Provision of HVAC climate
control may be necessary.
7) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed
Contractor (C-16) shall submit plans and details for review and approval prior to system installation
and Rough Inspections.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant shall be responsible for contacting the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Lucero Iiiiguez - Fire Safety Specialist
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 9125/2009
Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO
NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL
requirements listed below are complete. Incomplete applications or applications which cannot be processed will be
returned to applicant.
Date�lrl A Ci /�-3 Developer: I eAc�crl A-:�-'5c(A f
Tract No.: Tract Name: C� i'/ VVG Ll Lot No.(s): a (D j
Address(s): �5�5 QC1 5l U'Ll, C Phone Number: (I LVG) 3' 2T 5 - e P
The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the
Building & Safety Department:
CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW
TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW
COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW
WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW
1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad
(maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6
months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet
submittal until a Pad Elevation Certificate can be provided.
2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed
Soils Engineer. Recently rough graded residential developments which have a previously approved
geotechnical certification are exempt from this requirement.
3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots.
g. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10
plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy
plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with
grading plans & are subject to additional requirements. A current PM10 certification number is required.
5� Attach a copy of the rough or precise grading plan to the Public Works Department showing building
location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain
development plan.
6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations.
7, Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW
approved building construction projects require either a WQMP or a completed WQMP exemption form.
Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/planCheck/m search.aspx
I have reviewed and confirmed the requirements listed above as presented and find the improvements to be
sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s).
Pursuant to my findings, the above project may be released for building permit issuance.
This section completed by City- staff.
Recommended by:
Date: / /
Public Works Distribution: ( ) Green Sheet to Building & Safety
( ) Green Sheet to Planning Department
Declined for approval for reason(s) as follow(s), please correct and resubmit:
TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10 02-12.doc
City of La Quinta - PM10 Fugitive Dust Control Project Information
Construction Phase PM 10 Agreement (< 1 acre/lot or Infill Project)
Project Information
n
Project Contractor:
eel A e.v 1 � `: `( �C�OCJI�S
Project Phase
(check one)
Construction
Demolition
Project Name: Lc wc1 Vi & bci tctC o LL-,
Project Tract/Lot Numbers:
\ /
Project Street Address: ��' V 1�4- L�t�'( l)
lle,I CN `'11,1155
Total Acres in Active
Construction (< 1 acre per
Lot): o r5LP
Anticipated Start Date: I 0 23 Anticipated Completion Date: iZ /!!L/ 2
PM10 Contact Information
Please note: Dust control is required 24 hours a day, 7 days a week, regardless of
construction status. Person listed below is responsible for dust control during
business and non -business hours.
Name:'
.117
Kebcy4o 1\Ju Yw
Title:
j U C&G M `I r-(0 uv�
Company Name:
I
'&AC cyr IS ji c(l& 5
MailingAddress:
��'r uo VLI-V-l'letl �� �,
City, State, ZIP Code:
Cq I on
Primary Phone #:
u j a
Fax #:
24 Hour Emergency
Phone#:
Cell Phone #:
-4
Email Address:
�(�I � 'l @ tC.�G� eA'L c by,/'
PM10 Certificate #:
V �"?Jc g • LW1 �-__
The above stated property owner (or authorized representative):
Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to
SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP;
Shall constitute an Agreement to comply with all project conditions as identified in the approved dust
control plan.
Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week,
throughout the period of project performance, regardless of project size or status;
Shall ensure that each and every contractor, subcontractor and all other persons associated with the project
shall be in continuous compliance with all requirements of the approved dust control plan;
Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the
dust control plan are necessary;
o Shall authorize representatives of City/County to enter the property for inspection and/or abatement
purposes;
Shall hold harmless the City/County and its representatives from liability for any actions related to this dust
control plan or any Cit)OCoun1v in' 'ated atement activities.
Sign re of pe4ty wner or Autho ed Representative Date
City of La Quinta - PM 10 Fugitive Dust Control Plan (< 1 acre per Lot or Infill Project)
This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401,
402, 201, 203 and Portable Equipment Registration Program (PERP).
ee WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times
daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent:
■ Visible dust emissions >20% opacity
■ Visible dust emissions that travel > 100 feet from the source (within site)
■ Visible dust emissions that cross any property line
d• EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM10 class
and obtain* PM10 certificate number prior to construction activity (training information may be obtained by
contacting SCAQMD at (909) 396-2183).
CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Plan must be
kept on site. At least one short-term stabilization method must be used during off hours. At least one
long-term stabilization measure must be used within ten (10) days of ceasing activity.
WEATHER MONITORING: Wind predictions shall be monitored.
SIGNAGE: Approved signs shall be installed at a highly visible location. Please refer to the Coachella
Valley Fugitive Dust Control Plan Handbook for Construction Signage Guidelines.
TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles
operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum
traffic speed of 15mph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent
unauthorized traffic on pad.
PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only.
❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works
inspectors. No dirt on public or private roads. Track out shall be cleaned up within one (1) hour of incident
and at the conclusion of each workday.
.• DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading
requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile
or grading permit.
s FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can
be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can
replace PM10 fencing during the construction phase.
•: EQUIPMENT: Extra hoses and sprinklers shall be maintained on site.
.• EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also
be applied during excavation or grading operations.
.• DUMP TRUCKS: Open top dump trucks shall be wet down, moist and covered with a tarp prior to leaving
site.
4- INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required.
•: RECORD KEEPING: Fugitive Dust Control Plan records (i.e. self inspection records, records of use of
chemical suppressants, etc.) shall be maintained for 3 years by the Property Owner (or Authorized
Representative). Property Owner shall notify the City and SCAQMD within 10 days of completion of
project.
Water Qualitv Management Plan (WQMP) Exemption Fnrm - Whitpwntpr Riupr Rpninn
Documentation of Project Not Requiring a WQMP but Requiring Site Design BMPs and Source Control BMPs by
Entitlement Conditions of Approval or Permit Conditions — WQMP Required for the Listed Change of Land Uses
or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project)
Yes
No
Entitlement or construction of new single-family hillside residence(s) that create 10,000 square
feet, or more, of impervious area where the pre -development natural slope is 25% orgreater?
Entitlement or construction of new single-family hillside residence(s) that create 10,000 square
feet, or more, of impervious area where the pre -development natural slope is 10% or greater
where erosive soil conditions are known?
Entitlement or construction of new commercial and industrial development(s) of 100,000 square
feet or more?
Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint,
exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial
Classification (SIC) codes 5013, 7532, 7533, 7534, 7537, 7538, and 75391?
Entitlement or construction of new retail gasoline outlet(s) disturbing greater than 5,000 square
feet?
✓
Entitlement or construction of new restaurants) (or potential restaurant shell space) disturbing
greater than 5,000 square feet?
Entitlement or construction of new home subdivision(s) with 10 or more housing units?
Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or
more parking spaces, and potentially exposed to Urban Runoff?
Applicant Information
Name and Title
V1(6 Teeldt'y-w_ hyi
Company
�/ 5 ,[ �L
Phone
Email
U�C�61 Ce CAD iyl
Project Information
Project Name
Type (SFH, Multi -Family, Commercial, Etc.)
Location or Street Address
• ' L�t!l J
Nearest Cross Streets
al- MaC1► ��
Municipality/County/Zip Code
La Quinta
Tract Number(s) and/or Assessor Parcel Number(s)
1leQ . O�p
Other Location Information
�l Ce'
Watershed
Whitewater FUer
Source Control BMP Information
Size of Project Area (nearest 0.1 acre)
5cp CI CYO
Project Area managed with Site Design or Low
Impact Development (LID) BMPs (nearest 0.1 acre)
Is the project subject to onsite retention by City
ordinance or policy?
Name of the Entity that will implement, operate, and
maintain the Source Control BMPs
�L✓� D 52reCte, L)
Contact Name
A! r1 I; oo,(-GCS
Street or Mailing Address
e• % b Qrnff '�11, L
City
,14 L M j66/1�
Zip Code
A
Phone
-1tvI? Ina a-
Check Item
To be
Performed
Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control
Non -Structural BMP (See Appendix H, Section 4.5.2.1)
Ongoing Irrigation System and Landscape Maintenance
Ongoing Litter Control
Ongoing Drainage System Inspection & Maintenance
Education/Training for Property Owner, Operators, Occupants, or Employees
Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain,
Closed Trash Lids, Restriction of Vehicle Washing
Ongoing Street Sweeping at Private Streets and Private Parking Lots
Check Item
To be
Provided
Source Control BMP Requirements — Small Sloped Lots, Small Commercial, < 10 Unit
Subdivisions, <5,000 Square Ft. Parking Lots, Etc.
Structural BMP (See Appendix H, Section 4.5.2.2)
Storm Drain Inlet Stenciling and Signage
Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff
Protection of Slopes and Channels to Minimize Erosion
Multi -Family Project Use of Community Car Wash Racks
Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer
Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention
Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment
Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls
Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning
Procedures
Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water
Containment
Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment
Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment
Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy &
Containment
CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing
operation, maintenance, funding, transfer and implementation of the project -specific WQMP
requirements. Legal description and plat stamped by Registered Surveyor to be attached to the
applicable CC&R or Maintenance Agreement for recordation at Riverside County. (Optional
Requirement to be reviewed on a Project by Project basis)
BMP
The applicant shall comply with listed BMPs and applicable
provisions of the City's NPDES stormwater discharge permit,
LQMC Sections 8.70.010 et seq. (Stormwater Management
and Discharge Controls), and 13.24.170 (Clean Air/Clean
Water); Riverside County Ordinance No. 457; the California
Regional Water Quality Control Board — Colorado River Basin
Region Board Order No. 137-2008-0001 and the State Water
Resources Control Board's Order No. 99-08-DWQ.
Title:
Over -
Date:. 1a1Z_3
Phone: (�) , ' ,/ �
Certification
I certify that I have read this form in its entirety and
understand the City's submittal and review process and the
requirements for this form. I understand and agree that if
during the processing of the form, it is determined the
information contains errors or omissions, clarification and/or
supplemental information may be required and the
preparation of such information may be considered, in the
Community Development Director's judgment, an
unreasonable delay and will result in a suspension of
processing time limits in accordance with the California Code
of Regulations, Title 14, Section 15109.
Title:
Date: -9-/ff /2-3
Phone: (7�q-)Zl�- 4994
Owner Certification
I certify under the penalty of the laws of the State of
California that I am the property owner of the property that
is the subject matter of this application and I am authorizing
and hereby do consent to the filling of this application and
acknowledge that the final approval by the City of La Quinta,
if any, may result in restriction, limitations and construction
obligations being imposed on this real property.
Title: lr
Date: 9/1-9/ Z5
Phone: (%rj) 2 S -4994
South Coast Air Quality Management District
ackno)vledges by this
24 that
Rebekah Negron
rucce r dully completed
Rule 403.1 Coachella Valley Fugitive Dust Control Training
Certification is valid for 2 rears from the date of issuance �y /�
Date Issued: 08/17/2023 �ncdtccr� e4d4za
Training Officer
Cert #: CV2308-013291-14412 Compliance and Enforcement ,
Construction Debris Management Plan
Summary of Requirements
As of January 1, 2017, The Green Building Standards Code (CALGreen) requires that the construction
of most new structures in the State of California comply with sections 4.408 and 5.408 of the code in
accordance with Assembly Bill 939 requiring that no more than 35% of jobsite waste be disposed of as
trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under
certain conditions.
The City of La Quinta is committed to the highest level of environmental respect, to conserving our
precious natural resources and setting an example to provide for a better world for generations to come.
Recycling helps keep reusable resources out of landfills and will also reduce disposal costs.
IMPORTANT: Burrtec Waste & Recycling Services is the City's
franchise hauler. If you choose to self -haul any recyclables or trash, you
must provide copies of all weight tickets and/or receipts from the
transfer station, landfill, or recycler as the job progresses. Clean-up
companies and other haulers are not permitted to haul waste or
recyclables from the City of La Quinta. Self -haul weight tickets should be
submitted to: Mike Veto, Municipal Services Director -
mveto@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to:
41575 Eclectic Street, Palm Desert, CA. 92260.
THE HIDEAWAY
PROPERTY OWNERS ASSOCIATION
October 5, 2023
Lot 309 Via Bellagio LLC
45550 Kawea Way
Indian Wells, CA 92210
Re: Lot 309/53293 Via Bellagio
Construction Design Review #1
Dear Mr. Fedderly,
The Hideaway Design Review Committee (DRC) reviewed your construction drawing submittal at the
October 3, 2023 meeting.
The home has been approved to start construction, subject to the following comments being addressed prior
to the pre -construction meeting.
1. Please note most window and door details to not match the elevations. The elevations show the
head, sill and jamb conditions flush with the recess, while the details show a minimum one -inch
stucco surround. This is not considered a fall recess per the guidelines. Please revise plan details
to reflect the windows to be flush with the recess.
2. Please clarify the size of the mesh called out on the chimney caps. It needs to be small enough to
screen the metal manufacturers flue and should be painted black.
3. Please update and submit the solar plans to reflect the current approved drawings. The solar plans
show the garage outside the building envelope.
4. The facia line from the front of the cart garage to the back of the electrical room is 54'9" long
without a break. Please revise on the plans.
a. Building designs shall incorporate variedprojections such as wall offsets, trellises, covered porches or
verandas that create texture, shade, scale and visual interest. Building ridgelnres or side walls shall not
exceed 40-feet in one direction without a change in roof alignment, wall offset, fascia or elevation.
5. Please submit the plans with these revisions prior to requesting the pre -construction meeting.
6. The construction deposit and a copy of any building permits issued by the City of La Quinta must
be in hand prior to the request for a pre -construction meeting.
7. A Pre -Construction Meeting must be held prior to the commencement of construction and prior to
any temporary facilities (trash, toilet, electrical, signage, etc.) being brought on site.
8. A third -party lot is required to be obtained prior to the pre -construction meeting.
9. Please note that any proposed changes to these approved plans, that are considered during
construction, must be submitted to and approved by the DRC prior to installation.
10. Please provide a reduced set of hard copy plans with all of the approved elements included at the
pre -construction meeting.
11. All design review approvals are valid for one year.
80955 Avenue 52, La Quinta, CA 92253 • 760-393-5210
Please contact me with any questions regarding this review and to set up your pre -construction meeting.
Sincerely,
kA___
Kristen Johnson
DRC facilitator
For THE HIDEA WA Y DESIGN RE VIE W COMMITTEE
cc: Architect
Landscape Architect
80955 AvENUE 52 LA QUWTA, CALIFORN[A 92253 • P: 760.3 93.52 10 F: 760.3 98.5 78 8
STRUCTURAL ENGINEERING, INC.
CIVIL AND STRUCTURAL ENGINEERING
STRUCTURAL OBSERVATIONREPORT
ROOF DIAPHRAGMNAILING ONLY
March 28, 2024
City of La Quinta
Building And Safety Department
Re.: Lot 309 — The Hideaway
53-293 Via Bellagio,
La Quinta, CA.
Dear to whom it may concern,
Palm Desert Tel: 760-360-9998
Fax: 760-360-9903
Email: Reza(arastructural.com
www.Rastructural.com
We have performed structural observation per 2022 C.B.C. section 1704 for the
roof diaphragm nailing only.
Based on our visual observation and to the best of our knowledge and experience, we believe that
the roof diaphragm nailing was completed at the time of our visit, per approved plans.
Please note that this letter does not include or waive the responsibility for the City or the Special
Inspectors from determining compliance with the approved plans.
Please contact me should you need additional information regarding this approval.
Respectfully,
Reza Asgharpour, P.E.
PSGHg)
11711
*THIS IS ELECTRONIC SIGNATURE
77570 Springfield Lane, Ste D, Palm Desert CA 92211
STRUCTURAL ENGINEERING, INC.
CIVIL AND STRUCTURAL ENGINEERING
STRUCTURAL OBSERVATIONREPORT
EXTERIOR FRAMING ONLY
April 15, 2024
City of La Quinta
Building And Safety Department
Re.: Lot 309 — The Hideaway
53-293 Via Bellagio,
La Quinta, CA.
Dear to whom it may concern,
Palm Desert Tel: 760-360-9998
Fax: 760-360-9903
Email: Reza(arastructural.com
www.Rastructural.com
We have performed structural observation per 2022 C.B.C. section 1704 for the
framing condition prior to stucco at exterior only.
Based on our visual observation and to the best of our knowledge and experience, we believe that
the exterior framing that was completed at the time of our visit, per approved plans.
Please note that this letter does not include or waive the responsibility for the City or the Special
Inspectors from determining compliance with the approved plans.
Please contact me should you need additional information regarding this approval.
Respectfully,
(�2Reza Asgharpour, P.E.
C
*THIS IS ELECTRONIC SIGNATURE
77570 Springfield Lane, Ste D, Palm Desert CA 92211
Palm Desert Tel: 760-360-9998
STRUCTURAL ENGINEERING, INC. Fax:760-360--990tructural.com
CIVIL AND STRUCTURAL ENGINEERING www.Rastructural.com
STRUCTURAL OBSERVATIONREPORT
FRAMING ONLY
May 14, 2024
City of La Quinta
Building And Safety Department
Re.: Lot 309 — The Hideaway
53-293 Via Bellagio,
La Quinta, CA.
Dear to whom it may concern,
We have performed structural observation per 2022 C.B.C. section 1704 for the framing
condition prior to drywall and stucco.
Based on our visual observation and to the best of our knowledge and experience, we believe
that the framing was completed at the time of our visit, per approved plans.
Please note that this letter does not include or waive the responsibility for the City or the Special
Inspectors from determining compliance with the approved plans.
Please contact me should you need additional information regarding this approval.
Respectfully,
Reza Asgharpour, P.E.
*THIS IS ELECTRONIC SIGNATURE
77570 Springfield Lane, Ste D, Palm Desert CA 92211
October 12, 2023
CITY OF LA QUINTA - FINAL REVIEW
Permit No: BRES2023-0210
Interwest No.: LAQ23-0109
Non -Structural: 1.5-hours
Structural:.5-hours
City of La Quinta
Building Department
78-495 Calle Tampico
La Quinta, CA 92253
Plan Review: New SFR
Address: 53293 Via Bellagio
0
rvv
INTERWEST
A SAFEbuilt COMPANY
Interwest Consulting Group has completed a FINAL code compliance review of the following documents on behalf of
the City of La Quinta:
1. Drawings: PDF copy of following:
a. T1 through T3 dated 911812023 by Fedderly-Camarena Design, Inc.
b. G1 through G2 dated 911812023 by ESSI Engineering.
C. A1.0 through A9.3 dated 911812023 by Fedderly-Camarena Design, Inc.
d. F1.0 through F2.0 dated 911812023 by Fedderly-Camarena Design, Inc.
e. AD1 through AD8 dated 911812023 by Fedderly-Camarena Design, Inc.
f. GN through HFX-3 dated 911312023 by RA Structural Engineering.
g. E1.0 through E3.0 dated 911812023 by Fedderly-Camarena Design, Inc.
h M1.0 through M3.2 dated 911312023 by Scott Design and Title 24.
i. P1.0 through P4.0 dated 91712023 by EGD Designs.
j. L0.0 through L6.1 dated 911112023 by Fedderly-Camarena Design, Inc.
2. Structural Calculations: PDF copy dated 911312023 by RA Structural Engineering.
Structural Calculations: PDF copy dated 811412023 by RA Structural Engineering.
3. Energy Compliance Documentation: Included in plans by Scott Design and Title 24 Inc.
4. Geotechnical Investigation: PDF copy dated 4/21/2023 by Sladden Engineering.
The applicable provisions of the 2022 California Building Standards Code were used as the basis of this review.
Plan review comments follow on the attached list.
Enclosed, please find the above noted documents bearing Interwest Consulting Group's plan review stamps indicating
the documents have been reviewed for code compliance. Please do not hesitate to contact us directly with any
questions.
Sincerely,
INTERWEST CONSULTING GROUP
Eric Corral, Plans Examiner
1500 S. Haven Ave I Suite 220
Ontario, CA 91761
909.295-3142 INTERWESTORP.COM
7/31/23. 8:50 AM Invoice
0
INTERWEST
A SAFEbuilt COMPANY
INVOICE #89722
July 31, 2023
Jurisdiction No. BRES2023-0210
Interwest Job No. LAQ23-0109
Bill to: City of La Quinta Remit to: Interwest Consulting Group Direct questions to:
Attention Danny Castro 444 N. Cleveland Ave € Erica Cuevas
Design & Development Director Loveland, CO 80537 (970) 568-5034
78495 Calle Tampico € ecuevas@interwestgrp.com
La Quinta, CA 92253
Professional services for the period July 1 through July 31, 2023
RESIDENTIAL - SFR - LAQ23-0109 - BRES2023-0210
53293 Via Bellagio
Invoice Total $600.00
Employee Title Day Hours Rate Total
Eric Corral ICC Certified Plans Examiner 1 7/30 6 $100.001 $600.00
https://interwest.lucidbilling.com/invoices/print 1/1
INTERWEST
A swMbwr CORWO"
Bill to:
City of La Quinta
Ann Castro, Danny
Design and Development
Director
78-495 Calle Tampico
La Quinta, CA 92253
Remit to:
Interwest Consulting Group
P.O. Box 301069
Los Angeles, CA 90030-1069
Invoice #142476
October 13, 2023
Direct questions to
Erica Cuevas
ecuevas@interwestgrp.com
Professional services for the period October 1, 2023 through October 13, 2023
Residential - SFR - LAQ23-0109 - BRES2023-0210
Invoice Total (Please pay this amount) $230.00
Project $ Amount
Building & Safety Plan Review $230.00
Ref No. Project $ Amount
LAQ23-0109 lResidential - SFR - LAQ23-0109 - BRES2023-0210 1 $230.00
Employee Title
Eric Corral ICC Certified Plans Examiner
Eric Corral
LAQ23-0109 Residential - SFR - LAQ23-0109 - BRES2023-0210
Day Description
10/12/2023 1 LAQ23-0109
Hours Rate Total
2.00
$115.001
$230.00
$230.00
2.00
Hours
2.00
Total 2.00
loft
® M
JESIadden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201(760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
www.Sladdenengineering.com
April 21, 2023
Fedderly-Camarena Design, Inc.
38747 Nopales Road
Palm Desert, California 92211
Project: Proposed Custom Residence
53293 Via Bellagio
The Hideaway — Lot 309
La Quinta, California
Subject: Geotechnical Update
Project No. 544-13316
23-04-222
Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated
September 22, 2000; File No. 07117-10, Report No. 00-09-772
Report of Testing and Observation During Rough Grading prepared by ESSW dated
August 28, 2002; File No. 07117-11, Report No. 01-07-718
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647
In accordance with your request, we have reviewed the above referenced geotechnical reports as
they relate to the design and construction of the proposed custom residence. The project site is
located at 53293 Via Bellagio within the Hideaway Golf Club development in the City of La
Quinta, California. It is our understanding that the proposed residence will be a relatively
lightweight wood -frame structure supported by conventional shallow spread footings and
concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and
was subsequently regraded. The rough grading included over -excavation of the native surface
soil along with the placement of engineered fill soil to construct the building pads. The regrading
included processing the surface soil along with minor cuts and fills to construct the individual
building pads to the current configurations. Some additional over -excavation was performed in
areas where the building envelopes were reconfigured. The most recent site grading is
summarized in the referenced Report of Testing and Observations During Rough Grading
prepared by Sladden Engineering along with the compaction test results.
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. Based upon our review of the referenced reports, it is our opinion that the
structural values included in the referenced grading report prepared by Sladden Engineering
remain applicable for the design and construction of the proposed residential structure
foundations.
April 21, 2023 -2- Project No. 544-13316
23-04-222
The proposed residence may be supported upon conventional shallow spread footings.
Conventional shallow spread footings should be bottomed into properly compacted engineered
fill soil a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at
least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings
and isolated pad footings may be designed utilizing allowable bearing pressures of 1500 psf and
2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300
psf for each additional 6 inches of depth may be utilized, if desired. The maximum allowable
bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be
increased by one-third for wind and seismic loading.
Based on the recommended allowable bearing pressures, the total static settlement of the shallow
footings is anticipated to be less than one inch provided foundation area preparation conforms to
the recommendations included in this report. Differential static settlement is anticipated to be
approximately one-half of the total static settlement for similarly loaded footings spaced up to
approximately 40 feet apart.
Lateral forces may be resisted by friction along the base of the foundations/slabs and passive
resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load
forces is recommended for use in design. Passive resistance may be estimated using an
equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the
frictional resistance should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is non -expansive and falls within the "very low" expansion category in
accordance with 2022 California Building Code (CBC) classification criteria. Slab thickness and
reinforcement should be determined by the structural engineer. We recommend a minimum
floor slab thickness of 4.0 inches and minimum reinforcement of #3 bars at 24 inches on center in
both directions. All slab reinforcement should be supported on concrete chairs to ensure that
reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10-mil Visqueen, or equivalent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potential for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface cannot be achieved by grading, consideration should be given to
placing a thin leveling course of sand across the pad surface prior to placement of the membrane.
The seismic design category for a structure may be determined in accordance with Section 1613
of the 2022 CBC or ASCE7-16. According to the 2022 CBC, Site Class D measured may be used to
estimate design seismic loading for the proposed structures with a sufficient understanding of
the subsurface soil conditions. The 2022 CBC Site Specific Seismic Hazard Analyses are attached.
Sladden Engineering
April 21, 2023 -3- Project No. 544-13316
23-04-222
Because the lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building falls within the previously established building
envelope. The building area should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface soil should be compacted to a
minimum of 90 percent relative compaction prior to fill placement. Any fill material required to
attain design grades should be placed in thin lifts at near optimum moisture content and
compacted to at least 90 percent relative compaction.
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEERIN
Brett L. Anderson
Principal Engine
SER/ra
Copies: pdf / Addressee
BRETT L.
MDERSON Z
045389 m
GNIL
ENGINEERING
OF CAL
E R 1NG
0
HEW J. COHRT o
Matthew Cohrt 2634
Principal Geologis
�T OF CA0\
Sladden Engineering
,5qg,
-7 ,3-oq
Please verify that soils reports contain all of the above information. In addition, to assure
continuity between the investigationlreporting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions.
La Wnta Geotechnicag Report Checklist
Does the "Conclusions and Recommendations" section of the report address each of the
following criteria?
"Address' means:
(a) the criterion is considered significant and mitigation measure(s) noted, -or,
(b) the criterion is considered insigr)ificant and explicitly so stated.
yes -No C�Iterion
Foundation criteria based upon bearing capacity of natural or compacted soil.
El E3 Foundation criteria to mitigate the effects of expansive soils.
0 Foundation criteria based' upon bearing capacity I of natural or compacted soil.
0 0 Foundation criteria to mitigate.the effects of liquefaction.
El ® Foundation criteriato mitigate the effects of seismically Induced differential
settlement.
El Foundation criteria to mitigate the effects of long -terra differential settlement-
0 Foundation criteria to mitigate the effects of varying soil strength-
0 Foundation criteria to mitigate expected total and differential settlemen* t.
Any "No" answers to the above checklist should be noted as specific required
corrections.
H MMZ
Project: 53293 Via Bellagio, La Quinta
Project Number: 544-13316
Client: Fedderly-Camarena Design, Inc.
Site Lat/Long: 33.6613/-116.2570
Controlling Seismic Source: San Andreas
REFERENCE NOTATION
VALUE
Site Class C, D, D default, or E
D measured
Site Class D -Table 11.4-1 Fa
1.0
Site Class D - 21.3(ii) F
2.5
0.2*(SD1/SDS) TD
0.200
SDl/SDS Ts
1.000
Fundamental Period (12.8.2) T
Period
Seismic Design Maps or Fig 22-14 T,
8
Equation 11.4-4 - 2/3*SMI SDI
1.0000
Equation 11.4-2- Fv*S11 SMI
1.5000
Fv as determined by Section 21.3
Cr - At Perods <=0.2, Cr=CRs CRs 0.908
Cr - At Periods >=1.0, Cr=CRI CRI 0.891
Code based design value. See accompanying data for Site Specific Design values.
Sladden Engineering
SITE -SPECIFIC GROUND MOTION ANALYSIS
(ASCE 7-16)
REFERENCE
NOTATION
VALUE
REFERENCE
NOTATION
VALUE
Fv (Table 11.4-2)[Used for General Spectrum]
Fv
1.7
Design Maps
SS
1.500
0.2*(SD1/SDS)
To
0.136*
Design Maps
S1
0.600
SDI/SDS
Ts
0.68*
Equation 11.4-1- FA*Ss
SMs
1.500*
Equation 11.4-4 - 2/3*SM1
SDI
0.680*
Equation 11.4-3 - 2/3*SMs
SDS
1.00*
Equation 11.4-2 - Fv*S1
SMI
1.020*
Design Maps
PGA
0.639
Table 11.8-1
FPGA
1.1
Equation 11.8-1- FPGA*PGA
PGAM
0.703*
Section 21.5.3
80% of PGAM
0.562
Design Maps
CRs
0.908
Design Maps
CRI
0.891
RISK COEFFICIENT
Cr- At Periods between 0.2 and 1.0
Period
Cr
use trendline formula to complete
0.200
0.908
0.300
0.906
0.400
0.904
0.500
0.902
0.600
0.900
0.680
0.898
1.000
0.891
Mapped values from https://hazards.atcouncii.org/
https://www.seismicmaPS.org/
PROBABILISTIC SPECTRAL
2% in 50 year Exceedence
Period
UGHM
RTGM
Max Directional
Scale Factor
Probabilistic
MCE
0.010
0.800
0.769
1.19
0.915
0.100
1.335
1.308
1.19
1.557
0.200
1.776
1.749
1.20
2.099
0.300
2.036
1.938
1.22
2.364
0.500
2.019
1.864
1.23
2.293
0.750
1.672
1.522
1.24
1.887
1.000
1.429
1.275
1.24
1.581
2.000
0.823
0.730
1.24
0.905
3.000
0.565
0.498
1.25
0.623
4.000
0.417
0.365
1.25
0.456
5.000
0.318
0.280
1.26
0.353
2.50
2.00
1.50
0.50
0 00
Probabilistic PGA: 0.800
Is Probabilistic Saar ),)<1.2Fa? NO
Project No: 544-13316
1 Data Sources:
httDS://earthcivake.usgs.gov/hazards/interactive
httas://earthquake.usgs-gov/designmaps/rtgm/
z Shahi-Baker RotD100/RotD50 Factors (2014)
11
OBABI TIG
I PR MCER
SPECTRAL RESPONSE ACCELERATIONS
li ITi I I I ... _ I I. I_ ._�.. �I . I-.�._.�� i I
iii 11� 1 i�(1 1
--UGHM
-i- RTH M
-0-Probabilistic MCER
0.000 1.000 2.000 Period (seconds) 3.000 4.000 5.000
Sladden Engineering
DETERMINISTIC SPECTRUM
Largest Amplitudes of Ground Motions Considering All Sources Calculated using Weighted Mean of Attenuation Equations'
Controlling Source: San Andreas
Is Probabilistic Sa(max)<1.2Fa? NO
Period
Deterministic PSa
Median + 1.o for 5%
Damping
Max Directional Scale
Factor Z
Deterministic MCE
Section 21.2.2
Scaling Factor
Applied
0,010
0.624
1.19
0.742
0.7-1.2
0.020
0.626
1.19
0.745
0.745
0.030
0.637
1.19
0.758
0,758
0.050
0.681
1.19
0.811
0.811
0.075
0.821
1.19
0.977
0.977
0.100
0.976
1.19
1.162
1.162
0.150
1.206
1.20
1.448
1.448
0.200
1.351
1.20
1.621
1.621
0.250
1.446
1.21
1.750
1.750
0.300
1.494
1.22
1.822
1.822
0.400
1.496
1.23
1.841
1.841
0.500
1.441
1.23
1.772
1.772
0.750
1.158
1.24
1.436
1.436
1.000
0.968
1.24
1.200
1.200
1.500
0.695
1.24
0.861
0.861
2.000
0.530
1.24
0.657
0.657
3.000
0.363
1.25
0.454
0.454
4,000
0.258
1.25
0.322
0.322
5.000
0.192
1.26
1 0.242
1 0.242
2.00
1.50
0.50
000
® 0.000 1.000 2.000
Sladden Engineering _ Period (seconds)
Project No: 544-13316
Is Determinstic Sa(mex)<1.5*Fa?
NO
Section 21.2.2 Scaling Factor:
N/A
Deterministic PGA:
0.624
Is Deterministic PGA>=FPGA*0.5?
YES
' NGAWest 2 GMPE worksheet and
Uniform California Earthquake Rupture
Forecast, Version 3 (UCERF3) -Time
Dependent Model
2 Shahi-Baker RotD100/RotD50 Factors
(2014)
I
-�- Deterministic
MCER
SITF SPECIFIC SPECTRA
Period
Probabilistic
MCE
Deterministic
MCE
Site -Specific
MCE
Design Response
Spectrum (Sa)
0.010
0.915
0,742
0.742
0.495
0.100
1.557
1.162
1.162
0.775
0.200
2.099
1.621
1.621
1.081
0.300
2.364
1.822
1.822
1.215
0.500
2.293
1.772
1.772
1.181
0.750
1.887
1.436
1.436
0.957
1.000
1.581
1.200
1.200
0.800
2.000
0.905
0.657
0.657
0.438
3.000
0.623
0.454
0.454
0.303
4.000
0.456
0.322
0.322
0.215
5.000
0.353
1 0.242
1 0.242
0.161
SDS:
SD1:
SMS:
SM1:
Site Specific PGAm:
Site Class:
ASCE 7-16: Section 21.4
Site Specific
Calculated
Design
Value
Value
1.093
1.093
0.908
0.908
1.640
1.640
1.363
1.363
0.624
0.624
D measured
Seismic Design Category - Short* D
Seismic Design Category- 1s* D
* Risk Categories I, II, or III
Sladden Engineering
Period
ASCE 7 SECTION 21.3
General Spectrum
80% General
Response Spectrum
0.005
0.415
0.332
0.010
0.430
0.344
0.020
0.460
0.368
0.030
0.490
0.392
0.050
0.550
0.440
0.060
0.580
0.464
0.075
0.625
0.500
0.090
0.670
0.536
0.100
0.700
0.560
0.110
0.730
0.584
0.120
0.760
0.608
0.136
0.808
0.646
0.150
0.850
0.680
0.160
0.880
0.704
0.170
0.910
0.728
0.180
0.940
0,752
0.200
1.000
0.800
0.250
1.000
0.800
0.300
1.000
0.800
0.400
1.000
0.800
0.500
1.000
0.800
0.600
1.000
0.800
0.640
1.000
0.800
0.750
1.000
0.800
0.850
1.000
0.800
0.900
1.000
0.800
0.950
1.000
0.800
1.000
1.000
0.800
1.500
0.667
0.533
2.000
0.500
0.400
3.000
0.333
0.267
4.000
0.250
0.200
5.000
0.200
0.160
Project No: 544-13316
m
000 3.000 4.000 5.000
Period (seconds)
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
www.Sladdenengineering.com
August 7, 2023 Project No. 544-13316
23-08-399
Fedderly-Camerena Design, Inc.
38747 Nopales Road
Palm Desert, California 92211
Project: Proposed Custom Residence
53293 Via Bellagio
The Hideaway - Lot 309
La Quinta, California
Subject: Foundation and Precise Grading Plan Review
Ref: Geotechnical Update prepared by Sladden Engineering dated August 21, 2023;
Project No. 544-13316, Report No. 23-04-222
In accordance with your request, we have reviewed the Foundation Plans and Details prepared
by RA Structural Engineering, Inc. along with the Precise Grading Plans prepared by ESSI
Engineering for the proposed residential structure to be constructed at 53293 Via Bellagio within
The Hideaway development in the City of La Quinta, California. Based on our review, it is our
opinion that the recommendations provided in the above referenced Geotechnical Update as well
as the previous geotechnical reports have been properly incorporated into these plans.
If you have questions regarding this memo or the referenced report, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEEI
Brett L. Anderson
Principal Engineer
Letter/cg
G OFFSS/pN
BREiT L.
ANDERSON 2G.;
No. C45389 m
rr
CIVIL
ENGINEERING
OF CA1-1F� .
Copies: pdf / Addressee
Sladden Engineering
www.Sladdenengineering.com
Sladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201(760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite C, Buena Park, CA 90621(714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 99923 (951) 845-7743 Fax (951) 845-8863
www.Sladdenengineering.com
April 21, 2023 BRES2023-0210 Project No. 544-13316
23-04-222
Fedderly-Camarena Design, Inc.
38747 Nopales Road
Palm Desert, California 92211
Project: Proposed Custom Residence
53293 Via Bellagio
The Hideaway — Lot 309
La Quinta, California
Subject: Geotechnical Update
Reviewed for Code
Compliance
October 12, 2023
Interwest Consulting Group
Ref: Geotechnical Engineering Report prepared by Earth Systems
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE COM PL IANCE
By.-Deisy Mendez DATE 1011612023
outhwest (ESSW) dated
September 22, 2000; File No. 07117-10, Report No. 00-09-772
Report of Testing and Observation During Rough Grading prepared by ESSW dated
August 28, 2002; File No. 07117-11, Report No. 01-07-718
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647
In accordance with your request, we have reviewed the above referenced geotechnical reports as
they relate to the design and construction of the proposed custom residence. The project site is
located at 53293 Via Bellagio within the Hideaway Golf Club development in the City of La
Quinta, California. It is our understanding that the proposed residence will be a relatively
lightweight wood -frame structure supported by conventional shallow spread footings and
concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and
was subsequently regraded. The rough grading included over -excavation of the native surface
soil along with the placement of engineered fill soil to construct the building pads. The regrading
included processing the surface soil along with minor cuts and fills to construct the individual
building pads to the current configurations. Some additional over -excavation was performed in
areas where the building envelopes were reconfigured. The most recent site grading is
summarized in the referenced Report of Testing and Observations During Rough Grading
prepared by Sladden Engineering along with the compaction test results.
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. Based upon our review of the referenced reports, it is our opinion that the
structural values included in the referenced grading report prepared by Sladden Engineering
remain applicable for the design and construction of the proposed residential structure
foundations.
Sladden Engineering
April 21, 2023 -2- Project No. 544-13316
23-04-222
The proposed residence may be supported upon conventional shallow spread footings.
Conventional shallow spread footings should be bottomed into properly compacted engineered
fill soil a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at
least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings
and isolated pad footings may be designed utilizing allowable bearing pressures of 1500 psf and
2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300
psf for each additional 6 inches of depth may be utilized, if desired. The maximum allowable
bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be
increased by one-third for wind and seismic loading.
Based on the recommended allowable bearing pressures, the total static settlement of the shallow
footings is anticipated to be less than one inch provided foundation area preparation conforms to
the recommendations included in this report. Differential static settlement is anticipated to be
approximately one-half of the total static settlement for similarly loaded footings spaced up to
approximately 40 feet apart.
Lateral forces may be resisted by friction along the base of the foundations/slabs and passive
resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load
forces is recommended for use in design. Passive resistance may be estimated using an
equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the
frictional resistance should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is non -expansive and falls within the "very low" expansion category in
accordance with 2022 California Building Code (CBC) classification criteria. Slab thickness and
reinforcement should be determined by the structural engineer. We recommend a minimum
floor slab thickness of 4.0 inches and minimum reinforcement of #3 bars at 24 inches on center in
both directions. All slab reinforcement should be supported on concrete chairs to ensure that
reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10-mil Visqueen, or equivalent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potential for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface cannot be achieved by grading, consideration should be given to
placing a thin leveling course of sand across the pad surface prior to placement of the membrane.
The seismic design category for a structure may be determined in accordance with Section 1613
of the 2022 CBC or ASCE7-16. According to the 2022 CBC, Site Class D measured may be used to
estimate design seismic loading for the proposed structures with a sufficient understanding of
the subsurface soil conditions. The 2022 CBC Site Specific Seismic Hazard Analyses are attached.
Sladden Engineering
April 21, 2023 -3- Project No. 544-13316
23-04-222
Because the lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building falls within the previously established building
envelope. The building area should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface soil should be compacted to a
minimum of 90 percent relative compaction prior to fill placement. Any fill material required to
attain design grades should be placed in thin lifts at near optimum moisture content and
compacted to at least 90 percent relative compaction.
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEERIN
Brett L. Anderson
Principal Engine
SER/ra
Copies: pdf / Addressee
BRETT L.
MDERSON Z
045389 m
GNIL
ENGINEERING
OF CAL
E R 1NG
0
HEW J. COHRT o
Matthew Cohrt 2634
Principal Geologis
�T OF CA0\
Sladden Engineering
,5qg,
-7 ,3-oq
Please verify that soils reports contain all of the above information. In addition, to assure
continuity between the investigationlreporting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions.
La Wnta Geotechnicag Report Checklist
Does the "Conclusions and Recommendations" section of the report address each of the
following criteria?
"Address' means:
(a) the criterion is considered significant and mitigation measure(s) noted, -or,
(b) the criterion is considered insigr)ificant and explicitly so stated.
yes -No C�Iterion
Foundation criteria based upon bearing capacity of natural or compacted soil.
El E3 Foundation criteria to mitigate the effects of expansive soils.
0 Foundation criteria based' upon bearing capacity I of natural or compacted soil.
0 0 Foundation criteria to mitigate.the effects of liquefaction.
El ® Foundation criteriato mitigate the effects of seismically Induced differential
settlement.
El Foundation criteria to mitigate the effects of long -terra differential settlement-
0 Foundation criteria to mitigate the effects of varying soil strength-
0 Foundation criteria to mitigate expected total and differential settlemen* t.
Any "No" answers to the above checklist should be noted as specific required
corrections.
H MMZ
Project: 53293 Via Bellagio, La Quinta
Project Number: 544-13316
Client: Fedderly-Camarena Design, Inc.
Site Lat/Long: 33.6613/-116.2570
Controlling Seismic Source: San Andreas
REFERENCE NOTATION
VALUE
Site Class C, D, D default, or E
D measured
Site Class D -Table 11.4-1 Fa
1.0
Site Class D - 21.3(ii) F
2.5
0.2*(SD1/SDS) TD
0.200
SDl/SDS Ts
1.000
Fundamental Period (12.8.2) T
Period
Seismic Design Maps or Fig 22-14 T,
8
Equation 11.4-4 - 2/3*SMI SDI
1.0000
Equation 11.4-2- Fv*S11 SMI
1.5000
Fv as determined by Section 21.3
Cr - At Perods <=0.2, Cr=CRs CRs 0.908
Cr - At Periods >=1.0, Cr=CRI CRI 0.891
Code based design value. See accompanying data for Site Specific Design values.
Sladden Engineering
SITE -SPECIFIC GROUND MOTION ANALYSIS
(ASCE 7-16)
REFERENCE
NOTATION
VALUE
REFERENCE
NOTATION
VALUE
Fv (Table 11.4-2)[Used for General Spectrum]
Fv
1.7
Design Maps
SS
1.500
0.2*(SD1/SDS)
To
0.136*
Design Maps
S1
0.600
SDI/SDS
Ts
0.68*
Equation 11.4-1- FA*Ss
SMs
1.500*
Equation 11.4-4 - 2/3*SM1
SDI
0.680*
Equation 11.4-3 - 2/3*SMs
SDS
1.00*
Equation 11.4-2 - Fv*S1
SMI
1.020*
Design Maps
PGA
0.639
Table 11.8-1
FPGA
1.1
Equation 11.8-1- FPGA*PGA
PGAM
0.703*
Section 21.5.3
80% of PGAM
0.562
Design Maps
CRs
0.908
Design Maps
CRI
0.891
RISK COEFFICIENT
Cr- At Periods between 0.2 and 1.0
Period
Cr
use trendline formula to complete
0.200
0.908
0.300
0.906
0.400
0.904
0.500
0.902
0.600
0.900
0.680
0.898
1.000
0.891
Mapped values from https://hazards.atcouncii.org/
https://www.seismicmaPS.org/
PROBABILISTIC SPECTRAL
2% in 50 year Exceedence
Period
UGHM
RTGM
Max Directional
Scale Factor
Probabilistic
MCE
0.010
0.800
0.769
1.19
0.915
0.100
1.335
1.308
1.19
1.557
0.200
1.776
1.749
1.20
2.099
0.300
2.036
1.938
1.22
2.364
0.500
2.019
1.864
1.23
2.293
0.750
1.672
1.522
1.24
1.887
1.000
1.429
1.275
1.24
1.581
2.000
0.823
0.730
1.24
0.905
3.000
0.565
0.498
1.25
0.623
4.000
0.417
0.365
1.25
0.456
5.000
0.318
0.280
1.26
0.353
2.50
2.00
1.50
0.50
0 00
Probabilistic PGA: 0.800
Is Probabilistic Saar ),)<1.2Fa? NO
Project No: 544-13316
1 Data Sources:
httDS://earthcivake.usgs.gov/hazards/interactive
httas://earthquake.usgs-gov/designmaps/rtgm/
z Shahi-Baker RotD100/RotD50 Factors (2014)
11
OBABI TIG
I PR MCER
SPECTRAL RESPONSE ACCELERATIONS
li ITi I I I ... _ I I. I_ ._�.. �I . I-.�._.�� i I
iii 11� 1 i�(1 1
--UGHM
-i- RTH M
-0-Probabilistic MCER
0.000 1.000 2.000 Period (seconds) 3.000 4.000 5.000
Sladden Engineering
DETERMINISTIC SPECTRUM
Largest Amplitudes of Ground Motions Considering All Sources Calculated using Weighted Mean of Attenuation Equations'
Controlling Source: San Andreas
Is Probabilistic Sa(max)<1.2Fa? NO
Period
Deterministic PSa
Median + 1.o for 5%
Damping
Max Directional Scale
Factor Z
Deterministic MCE
Section 21.2.2
Scaling Factor
Applied
0,010
0.624
1.19
0.742
0.7-1.2
0.020
0.626
1.19
0.745
0.745
0.030
0.637
1.19
0.758
0,758
0.050
0.681
1.19
0.811
0.811
0.075
0.821
1.19
0.977
0.977
0.100
0.976
1.19
1.162
1.162
0.150
1.206
1.20
1.448
1.448
0.200
1.351
1.20
1.621
1.621
0.250
1.446
1.21
1.750
1.750
0.300
1.494
1.22
1.822
1.822
0.400
1.496
1.23
1.841
1.841
0.500
1.441
1.23
1.772
1.772
0.750
1.158
1.24
1.436
1.436
1.000
0.968
1.24
1.200
1.200
1.500
0.695
1.24
0.861
0.861
2.000
0.530
1.24
0.657
0.657
3.000
0.363
1.25
0.454
0.454
4,000
0.258
1.25
0.322
0.322
5.000
0.192
1.26
1 0.242
1 0.242
2.00
1.50
0.50
000
® 0.000 1.000 2.000
Sladden Engineering _ Period (seconds)
Project No: 544-13316
Is Determinstic Sa(mex)<1.5*Fa?
NO
Section 21.2.2 Scaling Factor:
N/A
Deterministic PGA:
0.624
Is Deterministic PGA>=FPGA*0.5?
YES
' NGAWest 2 GMPE worksheet and
Uniform California Earthquake Rupture
Forecast, Version 3 (UCERF3) -Time
Dependent Model
2 Shahi-Baker RotD100/RotD50 Factors
(2014)
I
-�- Deterministic
MCER
SITF SPECIFIC SPECTRA
Period
Probabilistic
MCE
Deterministic
MCE
Site -Specific
MCE
Design Response
Spectrum (Sa)
0.010
0.915
0,742
0.742
0.495
0.100
1.557
1.162
1.162
0.775
0.200
2.099
1.621
1.621
1.081
0.300
2.364
1.822
1.822
1.215
0.500
2.293
1.772
1.772
1.181
0.750
1.887
1.436
1.436
0.957
1.000
1.581
1.200
1.200
0.800
2.000
0.905
0.657
0.657
0.438
3.000
0.623
0.454
0.454
0.303
4.000
0.456
0.322
0.322
0.215
5.000
0.353
1 0.242
1 0.242
0.161
SDS:
SD1:
SMS:
SM1:
Site Specific PGAm:
Site Class:
ASCE 7-16: Section 21.4
Site Specific
Calculated
Design
Value
Value
1.093
1.093
0.908
0.908
1.640
1.640
1.363
1.363
0.624
0.624
D measured
Seismic Design Category - Short* D
Seismic Design Category- 1s* D
* Risk Categories I, II, or III
Sladden Engineering
Period
ASCE 7 SECTION 21.3
General Spectrum
80% General
Response Spectrum
0.005
0.415
0.332
0.010
0.430
0.344
0.020
0.460
0.368
0.030
0.490
0.392
0.050
0.550
0.440
0.060
0.580
0.464
0.075
0.625
0.500
0.090
0.670
0.536
0.100
0.700
0.560
0.110
0.730
0.584
0.120
0.760
0.608
0.136
0.808
0.646
0.150
0.850
0.680
0.160
0.880
0.704
0.170
0.910
0.728
0.180
0.940
0,752
0.200
1.000
0.800
0.250
1.000
0.800
0.300
1.000
0.800
0.400
1.000
0.800
0.500
1.000
0.800
0.600
1.000
0.800
0.640
1.000
0.800
0.750
1.000
0.800
0.850
1.000
0.800
0.900
1.000
0.800
0.950
1.000
0.800
1.000
1.000
0.800
1.500
0.667
0.533
2.000
0.500
0.400
3.000
0.333
0.267
4.000
0.250
0.200
5.000
0.200
0.160
Project No: 544-13316
m
000 3.000 4.000 5.000
Period (seconds)
DEFERRED TRUSS SUBMITTAL REQUEST
Date: 09/18/2023
Permit Application Number:
Project Street Address:
Applicant:
BRES2023-0210
53293 Via Bellagio
Fedderly and Associates
Policy Conditions and Acknowledgment:
7 Limited to Custom Residential Prefabricated Wood Trussed Roof Projects
W Q"fW
CAI IFORIN r
BRES2023-0210
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE COM PLIANCE
-:Deisy Mendez DATE. 70/7612025
Submittal Package Shall Consist of Electronically Stamped and Signed Truss Calculations with Engineer
of Record's Acceptance and a Roof Truss Layout
W] City Anticipated Initial Review Time is Ten (10) Working Days with Rechecks of Five (5) Workings Days
Fee for Plan Review and Processing will be the Actual Hourly Cost Incurred by the City Consultant and
the Hourly Cost per the Applicable Fee Schedule for City Staff
7 Approval and Payment of Fees are Required Prior to Request for Roof Nail Inspection, No Exceptions
By signing this form, the applicant agrees to, and will be solely responsible for any delays incurred by not
complying with, the ' elines, on itio and requirements as identified.
Signat
//�� �� Nete: Aenlieant may erint out and sign
f�rT+ by hand and then return a scanned
cony back for review and annreyal
City Staff
Approved By:
BRES2023-0210
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name: Hideaway 309 ":)
A �l_Tn Date/Time: 2023-09-13T11:13:25-07:00 (Page 1 of 18)
Calculation Description: Title 24 Analysis CITY OF LA QUI N p& Fil Name: Hideaway Lot 309-Fedderly-23.ribd22x
RI III IIimr. niyi-sInm 9FF4,wAWJ10%
GENERAL INFORMATION
REVIEWED FOR
01
Project Name
Hideawa
_
309 CODECOMPUANCE
Compliance
02
Run Title
Title 24 F
i&f Piss/ Mentie� DATE: 10/16/-093
October
03
Project Location
Lot 309, .
_
3293 via Bellagio
04
City
La Quinta
05
Standards Version
2022
06
Zip code
92253
07
Software Version
EnergyPro 9.2
08
Climate Zone
15
09
Front Orientation (deg/ Cardinal)
45
10
Building Type
Single family
11
Number of Dwelling Units
1
12
Project Scope
Newly Constructed
13
Number of Bedrooms
5
14
Addition Cond. Floor Area (ft2)
0
15
Number of Stories
2
16
Existing Cond. Floor Area (ft2)
n/a
17
Fenestration Average U-factor
0.37
18
Total Cond. Floor Area (ft2)
6628
19
Glazing Percentage (%)
30.34%
20
ADU Bedroom Count
n/a
21
ADU Conditioned Floor Area
n/a
22
Fuel Type
Natural gas
23
Occupancy U:
No
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 2 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
ENERGY DESIGN RATINGS
Energy Design Ratings
Compliance Margins
Source Energy
(EDR')
Efficiency' EDR
(EDR2efficiency)
Totalz EDR
(EDR2total)
Source Energy
(EDR')
Efficiency' EDR
(EDR2efficiency)
TotalZ EDR
(EDR2total)
Standard Design
27.6
39
19.2
Proposed Design
25.4
37.5
18.1
2.2
1.5
1.1
RESULTS: PASS
'Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
• Standard Design PV Capacity: 9.98 kWdc
• PV System resized to 9.98 kWdc (a factor of 9.979) to achieve 'Standard Design PV' PV scaling
...d Ikw.CR . _,
HERS P R O V I O L
Registration Number: Registration Date/Time: HERS Provider:
223-P016586973A-000-000-0000000-0000 2023-09-13 11:24:33 CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-09-13T11:13:25-07:00
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
CF1R-PRF-01E
(Page 3 of 18)
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ftz -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ftz -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ftz -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ftz -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating
0.73
3.38
0.88
6.28
-0.15
-2.9
Space Cooling
3.23
65.56
2.83
60.37
0.4
5.19
IAQ Ventilation
0.25
2.65
0.25
2.65
0
0
Water Heating
0.33
3.35
0.15
2.72
0.18
0.63
Self
Utilization/Flexibility
Credit
0
0
Efficiency Compliance
Total
4.54
74.94
4.11
72.02
0.43
2.92
Photovoltaics
-1.77
-47.87
-1.77
-47.73
Battery
0
0
Flexibility
Indoor Lighting
0.39
3.75
0.39
3.75
Appl. & Cooking
1.01
6.52
1
6.47
Plug Loads
1.11
11.21
1.11
11.21
Outdoor Lighting
0.11
1
0.11
1
TOTAL COMPLIANCE
5.39
49.55
4.95
46.72
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-09-13T11:13:25-07:00
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
CF1R-PRF-01E
(Page 4 of 18)
ENERGY USE INTENSITY
Standard Design (kBtu/ftz - yr)
Proposed Design (kBtu/ftz - yr)
Compliance Margin (kBtu/ftz - yr)
Margin Percentage
Gross EUI'
11.03
10.06
0.97
8.79
Net EUI'
2.25
1.28
0.97
43.11
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
REQUIRED PV SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
12
DC System Size
Azimuth
Tilt
Array Angle
Tilt: (x in
Inverter Eff.
Annual
(kWdc)
Exception
Module Type
Array Type
Power Electronics
CFI
(deg)
Input
(deg)
12)
N
Solar Access
N
9.98
NA
Standard (14-17%)
Fixed
none
true
150-270
n/a
n/a
<=7:12
96
98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
• Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
Registration Number:
223-P016586973A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2022 Residential Compliance
Registration Date/Time:
2023-09-13 11:24:33
Report Version: 2022.0.000
Schema Version: rev 20220901
HERS Provider:
CaICERTS inc.
Report Generated: 2023-09-13 11:15:28
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name: Hideaway 309 Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 5 of 18)
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
• Quality insulation installation (QII)
• Indoor air quality ventilation
• Kitchen range hood
• Minimum Airflow
• Verified EER/EER2
• Verified SEER/SEER2
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
• Verified HSPF
• Verified heat pump rated heating capacity
• Duct leakage testing
• Low -leakage Air Handling Unit
• Compact distribution system expanded credit
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftz)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Hideaway 309
6628
1
5
4
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft2)
Avg. Ceiling Height
Water Heating System 1
Status
Master Suite
Conditioned
AC-11
1006
11
DHW Sys 1
New
Guest Casita
Conditioned
AC-22
1100
10
DHW Sys 1
New
Living Area
Conditioned
AC-3 & 43
3276
12
DHW Sys 1
New
Second Floor
Conditioned
AC-54
1246
9
DHW Sys 1
New
Registration Number: Registration Date/Time: HERS Provider:
223-P016586973A-000-000-0000000-0000 2023-09-13 11:24:33 CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-09-13T11:13:25-07:00
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
CF1R-PRF-01E
(Page 6 of 18)
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
NE Wall
Master Suite
R-21 Wall
45
Front
30
0
90
SE Wall
Master Suite
R-21 Wall
135
Left
120
10.8
90
SW Wall
Master Suite
R-21 Wall
225
Back
324
149.6
90
300d Wall
Master Suite
R-21 Wall
300
n/a
60
34.4
90
NW Wall
Master Suite
R-21 Wall
315
Right
472
50.2
90
NE Wall 2
Guest Casita
R-21 Wall
45
Front
390
118.3
90
SE Wall 2
Guest Casita
R-21 Wall
135
Left
330
135
90
SW Wall 2
Guest Casita
R-21 Wall
225
Back
180
89
90
NW Wall 2
Guest Casita
R-21 Wall
315
Right
330
18.9
90
NE Wall 3
Living Area
R-21 Wall
45
Front
649
164
90
SE Wall 3
Living Area
R-21 Wall
135
Left
1248
196.5
90
SW Wall 3
Living Area
R-21 Wall
225
Back
636
360
90
NW Wall 3
Living Area
R-21 Wall
315
Right
612
418.01
90
NE Wall 4
Second Floor
R-21 Wall
45
Front
288
60
90
SE Wall 4
Second Floor
R-21 Wall
135
Left
486
45
90
SW Wall 4
Second Floor
R-21 Wall
225
Back
288
117
90
NW Wall 4
Second Floor
R-21 Wall
315
Right
486
44
90
Roof
Master Suite
R-38/ R19 vented
n/a
n/a
1006
n/a
n/a
Roof 2
Guest Casita
R-38/ R19 vented
n/a
n/a
1100
n/a
n/a
Roof 3
Living Area
R-38/ R19 vented
n/a
n/a
3276
n/a
n/a
Roof 4
Second Floor
R-38/ R19 vented
n/a
n/a
1246
n/a
n/a
Raised Floor
Second Floor
R-19 Floor (F.19.2x8.16)
n/a
n/a
1246
n/a
n/a
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-09-13T11:13:25-07:00
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
CF1R-PRF-01E
(Page 7 of 18)
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Ventilated
3
0.61
0.88
No
Yes
Attic Guest Casita
Attic RoofGuest Casita
Ventilated
3
0.61
0.88
No
Yes
Attic Living Area
Attic Roof Living Area
Ventilated
3
0.61
0.88
No
Yes
Attic Second Floor
Attic RoofSecond Floor
Ventilated
3
0.61
0.88
No
Yes
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
(ft2) Area
U factor
Source U-factor
SHGC
SHGC Source
Exterior Shading
C
Window
SE Wall
Left
135
1
3.6
0.34
NFRC
0.23
NFRC
Bug Screen
C 2
Window
SE Wall
Left
135
1
3.6
0.34
NFRC
0.23
NFRC
Bug Screen
C 3
Window
SE Wall
Left
135
1
3.6
0.34
NFRC
0.23
NFRC
Bug Screen
4
Window
SW Wall
Back
225
12
10
1
120
0.4
NFRC
0.21
NFRC
Bug Screen
E2
Window
SW Wall
Back
225
1
29.6
0.34
NFRC
0.23
NFRC
Bug Screen
E
Window
300d Wall
300
1
6.4
0.34
NFRC
0.23
NFRC
Bug Screen
E1
Window
300d Wall
300
1
28
0.34
NFRC
0.23
NFRC
Bug Screen
D1
Window
NW Wall
Right
315
1
6.2
0.34
NFRC
0.23
NFRC
Bug Screen
D
Window
NW Wall
Right
315
1
44
0.34
NFRC
0.23
NFRC
Bug Screen
GE
Window
NE Wall 2
Front
45
1
6.3
0.34
NFRC
0.23
NFRC
Bug Screen
GD
Window
NE Wall 2
Front
45
1
56
0.36
NFRC
0.18
NFRC
Bug Screen
GC
Window
NE Wall 2
Front
45
1
56
0.34
NFRC
0.23
NFRC
Bug Screen
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-09-13T11:13:25-07:00
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
CF1R-PRF-01E
(Page 8 of 18)
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
(ftz) Area
U-factor
Source U-factor
SHGC
SHGC Source
Exterior Shading
GB1
Window
SE Wall 2
Left
135
1
55
0.34
NFRC
0.24
NFRC
Bug Screen
2
Window
SE Wall 2
Left
135
1
80
0.4
NFRC
0.21
NFRC
Bug Screen
GB
Window
SW Wall 2
Back
225
1
33
0.34
NFRC
0.23
NFRC
Bug Screen
12
Window
SW Wall 2
Back
225
1
30
0.34
NFRC
0.24
NFRC
Bug Screen
GA
Window
SW Wall 2
Back
225
1
26
0.34
NFRC
0.23
NFRC
Bug Screen
GF
Window
NW Wall 2
Right
315
1
6.3
0.34
NFRC
0.23
NFRC
Bug Screen
GF 2
Window
NW Wall 2
Right
315
1
6.3
0.34
NFRC
0.23
NFRC
Bug Screen
GF 3
Window
NW Wall 2
Right
315
1
6.3
0.34
NFRC
0.23
NFRC
Bug Screen
B1
Window
NE Wall 3
Front
45
1
68
0.34
NFRC
0.23
NFRC
Bug Screen
A
Window
NE Wall 3
Front
45
1
23
0.34
NFRC
0.23
NFRC
Bug Screen
1
Window
NE Wall 3
Front
45
5
10
1
50
0.4
NFRC
0.21
NFRC
Bug Screen
M1
Window
NE Wall 3
Front
45
1
23
0.34
NFRC
0.23
NFRC
Bug Screen
B
Window
SE Wall 3
Left
135
1
50
0.34
NFRC
0.23
NFRC
Bug Screen
H
Window
SE Wall 3
Left
135
1
32.5
0.36
NFRC
0.18
NFRC
Bug Screen
G
Window
SE Wall 3
Left
135
1
18
0.34
NFRC
0.23
NFRC
Bug Screen
8
Window
SE Wall 3
Left
135
1
24
0.38
NFRC
0.2
NFRC
Bug Screen
F
Window
SE Wall 3
Left
135
1
12
0.34
NFRC
0.23
NFRC
Bug Screen
F1
Window
SE Wall 3
Left
135
6
2
1
12
0.34
NFRC
0.23
NFRC
Bug Screen
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2023-09-13T11:13:25-07:00
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
CF1R-PRF-01E
(Page 9 of 18)
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
(ftz) Area
U-factor
Source U-factor
SHGC
SHGC Source
Exterior Shading
F 2
Window
SE Wall 3
Left
135
6
2
1
12
0.34
NFRC
0.23
NFRC
Bug Screen
F1 2
Window
SE Wall 3
Left
135
6
2
1
12
0.34
NFRC
0.23
NFRC
Bug Screen
7
Window
SE Wall 3
Left
135
6
2
2
24
0.38
NFRC
0.2
NFRC
Bug Screen
6
Window
SW Wall 3
Back
225
24
10
1
240
0.4
NFRC
0.21
NFRC
Bug Screen
42
Window
SW Wall 3
Back
225
12
10
1
120
0.4
NFRC
0.21
NFRC
Bug Screen
5
Window
NW Wall 3
Right
315
17.5
10
1
175
0.4
NFRC
0.21
NFRC
Bug Screen
M
Window
NW Wall 3
Right
315
1
90
0.36
NFRC
0.18
NFRC
Bug Screen
L
Window
NW Wall 3
Right
315
10.7
14.3
1
151.0
0.34
NFRC
0.23
NFRC
Bug Screen
2F
Window
NE Wall 4
Front
45
1
40
0.36
NFRC
0.18
NFRC
Bug Screen
2F1
Window
NE Wall 4
Front
45
1
20
0.36
NFRC
0.18
NFRC
Bug Screen
2E
Window
SE Wall 4
Left
135
1
8
0.34
NFRC
0.23
NFRC
Bug Screen
2D
Window
SE Wall 4
Left
135
1
4
0.34
NFRC
0.23
NFRC
Bug Screen
2D 2
Window
SE Wall 4
Left
135
1
4
0.34
NFRC
0.23
NFRC
Bug Screen
2D 3
Window
SE Wall 4
Left
135
1
4
0.34
NFRC
0.23
NFRC
Bug Screen
2C
Window
SE Wall 4
Left
135
1
12.5
0.36
NFRC
0.18
NFRC
Bug Screen
2C 2
Window
SE Wall 4
Left
135
1
12.5
0.36
NFRC
0.18
NFRC
Bug Screen
2B
Window
SW Wall 4
Back
225
1
9
0.34
NFRC
0.23
NFRC
Bug Screen
13
Window
SW Wall 4
Back
225
1
108
0.4
NFRC
0.21
NFRC
Bug Screen
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 10 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
(ft2) Area
U-factor
Source U-factor
SHGC
SHGC Source
Exterior Shading
2A
I
Window
I
NW Wall 4
Right
I
315
I
I
1
I
20
I
0.34
I
NFRC
I
0.23
I
NFRC
I
Bug Screen
2G
L
Window
NW Wall 4
Right
-
315
1
24
0.34
NFRC
0.23
NFRC
Bug Screen
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
4
20
0.1
20
20
0
0
0
0
0
0
0
0
0
1
3
0.1
3
3
0
0
0
0
0
0
0
0
0
F1
3
0.1
3
3
0
0
0
0
0
0
0
0
0
F2
3
0.1
3
3
0
0
0
0
0
0
0
0
0
F12
3
0.1
3
3
0
0
0
0
0
0
0
0
0
7
3
0.1
3
3
0
0
0
0
0
0
0
0
0
6
14
0.1
14
14
0
0
0
0
0
0
0
0
0
4 2
22
0.1
22
22
0
0
0
0
0
0
0
0
0
5
22
0.1
22
22
0
0
0
0
0
0
0
0
0
L
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 11 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
SLAB FLOORS
01
02
03
04
05
06
07
08
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction
Heated
Slab
Master Suite
1006
92
none
0
80%
No
Slab 2
Guest Casita
1100
126
none
0
80%
No
Slab 3
Living Area
3276
259
none
0
80%
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Inside Finish: Gypsum Board
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Attic RoofMaster Suite
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-19
None / 0
0.059
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Attic RoofGuest Casita
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-19
None / 0
0.059
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Attic Roof Living Area
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-19
None / 0
0.059
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 12 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofSecond Floor
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-19
None / 0
0.059
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Floor Surface: Carpeted
R-19 Floor (F.19.2x8.16)
Floors Over
Wood Framed Floor
2x8 @ 16 in. O. C.
R-19
None /None
0.047
Floor Deck: Wood
Crawlspace
Siding/sheathing/decking
Cavity / Frame: R-19 / 2x8
Ceilings (below
Wood Framed
Over Ceiling Joists: R-28.9 insul.
R-38/ R19 vented
attic)
Ceiling
2x4 @ 16 in. 0. C.
R-38
None / None
0.025
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
05
Quality Insulation Installation (QII)
High R-value Spray Foam Insulation
Building Envelope Air Leakage
CFM50
CFM50
Required
Not Required
N/A
n/a
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
09
Name
System Type
Distribution Type
Water Heater Name
Number of Units
Solar Heating
Compact
HERS Verification
Water Heater
System
Distribution
Name (#)
DHW Sys 1
Domestic Hot
Standard
DHW Heater 1
2
n/a
Expanded
DHW Sys
DHW Heater 1 (2)
Water (DHW)
1-hers-dhw
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 13 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
WATER HEATERS - NEEA HEAT PUMP
01
02
03
04
05
06
07
08
Name
# of Units
Tank Vol. (gal)
NEEA Heat Pump
NEEA Heat Pump
Tank Location
Duct Inlet Air Source
Duct Outlet Air Source
Brand
Model
AOSmithHPS1080H4
DHW Heater 1
2
80
A. O. Smith
Outside
Living Area
Living Area
5DV2xx
WATER HEATING - COMPACT DISTRIBUTION
01
02
03
04
05
06
07
Master Bath distance of
Kitchen distance of
Furthest Third furthest
Dwelling Unit type
Water Heating System
furthest fixture to Water
furthest fixture to Water
fixture to Water Heater
Compactness Factor
HERS Verification
Name
Heater (ft)
Heater (ft)
(ft)
Dwelling
DHW Sys 1
n/a
n/a
n/a
0.6
Expanded Credit
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Compact Distribution
Type
Recirculation Control
Shower Drain Water Heat
Recovery
DHW Sys 1- 1/2
Not Required
Not Required
Required
Expanded
Not Required
Not Required
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Name
System Type
Heating Unit Name
Heating Equipment
Cooling Unit Name
Cooling Equipment
Fan Name
Distribution Name
Required
Count
Count
Thermostat Type
AC-11
Heat pump
Heat Pump System
1
Heat Pump System
1
HVAC Fan 1
Air Distribution
Setback
heating cooling
1
1
System 1
AC-22
Heat pump
Heat Pump System
1
Heat Pump System
1
HVAC Fan 2
Air Distribution
Setback
heating cooling
2
2
System 2
AC-3 & 43
Heat pump
Heat Pump System
2
Heat Pump System
2
HVAC Fan 3
Air Distribution
Setback
heating cooling
3
3
System 3
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 14 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Name
System Type
Heating Unit Name
Heating Equipment
Cooling Unit Name
Cooling Equipment
Fan Name
Distribution Name
Required
Count
Count
Thermostat Type
AC-54
Heat pump
Heat Pump System
1
Heat Pump System
1
HVAC Fan 4
Air Distribution
Setback
heating cooling
4
4
System 4
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
12
13
Heating
Cooling
Name
System Type
Number of
Units
Zonally
Controlled
Compressor
Type
HERS Verification
Efficiency
HSPF /
Efficiency
SEER /
EER /
HSPF2 /
Cap 47
Cap 17
EER /
Type
COP
Type
SEER2
CEER
Heat Pump
Central split HP
1
HSPF
10
47000
30550
EERSEER
18
13
Not Zonal
Single
Heat Pump System
System 1
Speed
1-hers-htpump
Heat Pump
Central split HP
1
HSPF
10
47000
30550
EERSEER
18
13
Not Zonal
Single
Heat Pump System
System 2
Speed
2-hers-htpump
Heat Pump
Central split HP
2
HSPF
10
55500
36075
EERSEER
18
13
Not Zonal
Single
Heat Pump System
System 3
Speed
3-hers-htpump
Heat Pump
Central split HP
1
HSPF
10
55500
36075
EERSEER
18
13
Not Zonal
Single
Heat Pump System
System 4
Speed
4-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER/EER2
Verified
Verified Refrigerant
Verified
Verified Heating
Verified Heating
SEER/SEER2
Charge
HSPF/HSPF2
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
1-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
2-hers-htpump
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 15 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER/EER2
Verified
Verified Refrigerant
Verified
Verified Heating
Verified Heating
SEER/SEER2
Charge
HSPF/HSPF2
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
3-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
Yes
Yes
Yes
4-hers-htpump
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
12
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design Type
Bypass Duct
Duct Leakage
HERS Verification
Supply
Return
Supply
Return
Supply
Return
Air Distribution
Unconditioned
Non Verified
R 8
R 8
Attic
Attic
n/a
n/a
No Bypass Duct
Air Distribution
System 1
attic
System 1-hers-dist
Air Distribution
Unconditioned
Non Verified
R 8
R 8
Attic
Attic
n/a
n/a
No Bypass Duct
Air Distribution
System 2
attic
System 2-hers-dist
Air Distribution
Unconditioned
Non Verified
R 8
R 8
Attic
Attic
n/a
n/a
No Bypass Duct
Air Distribution
System 3
attic
System 3-hers-dist
Air Distribution
Unconditioned
Air Distribution
Non Verified
R 8
R 8
Attic
Attic
n/a
n/a
No Bypass Duct
System 4
attic
System 4-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
Target (%)
Location
Design
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
6.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 1-hers-dirt
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 16 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
Target (%)
Location
Design
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
6.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 2-hers-dirt
Air Distribution
Yes
6.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 3-hers-dirt
Air Distribution
Yes
6.0
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 4-hers-dirt
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 1
HVAC Fan
0.35
HVAC Fan 1-hers-fan
HVAC Fan 2
HVAC Fan
0.35
HVAC Fan 2-hers-fan
HVAC Fan 3
HVAC Fan
0.35
HVAC Fan 3-hers-fan
HVAC Fan 4
HVAC Fan
0.35
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.35
HVAC Fan 2-hers-fan
Required
0.35
HVAC Fan 3-hers-fan
Required
0.35
HVAC Fan 4-hers-fan
Required
0.35
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 17 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
INDOOR AIR QUALITY (IAQ) FANS
01
02
03
04
05
06
07
08
09
Dwelling Unit
Airflow (CFM)
Fan Efficacy
IAQ Fan Type
Includes
Heat/Energy
IAQ Recovery
Includes Fault
HERS Verification
Status
(W/CFM)
Recovery?
Effectiveness - SRE
Indicator Display?
SFam IAQVentRpt
216
0.35
Exhaust
No
n/a / n/a
No
Yes
� CaICERTS, p� t f
HERS PROVI tN
Registration Number: Registration Date/Time: HERS Provider:
223-P016586973A-000-000-0000000-0000 2023-09-13 11:24:33 CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 309
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-09-13T11:13:25-07:00 (Page 18 of 18)
Input File Name: Hideaway Lot 309-Fedderly-23.ribd22x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2023-09-13 11:24:33
Address:
CEA/ HERS Certification Identification (If applicable):
77085 Michigan Dr.
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2023-09-13 11:24:33
Address:
License:
77085 Michigan Dr.
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Number:
223-PO 1 6586973A-000-000-0000000-0000
Registration Date/Time:
2023-09-13 11:24:33
HERS Provider:
Easy to Verify
at CaICERTS.com
CaICERTS inc.
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2023-09-13 11:15:28
Schema Version: rev 20220901
RTIFICATE OF OCCUPANCY
DESIGN AND DEVELOPMENT DEPARTMENT
This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the
California Residential Code, certifying that, at the time of issuance, this structure was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 53293 VIA BELLAGIO
Use Classification: Building Residential
Occupancy Group: R-3: 1 & 2 Family Type of Construction: V-B
Dwellings
Code Edition: 2022 Sprinkler Installed: YES
By: Edward Ghera
Date: 1 /22/2025 12: OO:OOAM
Building Official: AJ ORTEGA
taQ�(v
Permit No.: BRES2023-0210
Land Use Zone: RL
Sprinkler Required: YES
Owner of Building: Via Bellaigo LLC
Address: 38-747 Nopales Rd
City, ST, ZIP: Palm Desert, CA 92211
GEM ofthe DESERT — POST IN A CONSPICUOUS PLACE