Loading...
BRES2023-0210 - Energy Calcs Revision 1CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 1 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 GENERAL INFORMATION 01 Project Name Hideaway 309 02 Run Title Title 24 Analysis 03 Project Location Lot 309, 53293 via Bellagio 04 City La Quinta 05 Standards Version 2022 06 Zip code 92253 07 Software Version EnergyPro 9.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)45 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 5 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.37 18 Total Cond. Floor Area (ft 2)6628 19 Glazing Percentage (%)30.34% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. BRES2023-0210 - 53293 VIA BELLAGIO REVISION 1 REVISED ENERGY TO REFLECT FENESTRATION ON SITE. 2022 CALIFORNIA BUILDING CODES. 02/15/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 2 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 27.6 39 19.2 Proposed Design 25.4 37.7 18.2 2.2 1.3 1 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 9.98 kWdc •PV System resized to 9.98 kWdc (a factor of 9.979) to achieve 'Standard Design PV' PV scaling 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 3 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.73 3.38 0.88 6.25 -0.15 -2.87 Space Cooling 3.23 65.56 2.84 60.67 0.39 4.89 IAQ Ventilation 0.25 2.65 0.25 2.65 0 0 Water Heating 0.33 3.35 0.15 2.71 0.18 0.64 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 4.54 74.94 4.12 72.28 0.42 2.66 Photovoltaics -1.77 -47.87 -1.77 -47.74 Battery 0 0 Flexibility Indoor Lighting 0.39 3.75 0.39 3.75 Appl. & Cooking 1.01 6.52 1 6.47 Plug Loads 1.11 11.21 1.11 11.21 Outdoor Lighting 0.11 1 0.11 1 TOTAL COMPLIANCE 5.39 49.55 4.96 46.97 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 4 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 - yr )Proposed Design (kBtu/ft 2 - yr )Compliance Margin (kBtu/ft 2 - yr ) Margin Percentage Gross EUI 1 11.03 10.08 0.95 8.61 Net EUI 2 2.25 1.31 0.94 41.78 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 9.98 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Insulation below roof deck •Window overhangs and/or fins •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 5 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Verified HSPF •Verified heat pump rated heating capacity •Duct leakage testing •Low-leakage Air Handling Unit •Compact distribution system expanded credit BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Hideaway 309 6628 1 5 4 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status Master Suite Conditioned AC-11 1006 11 DHW Sys 1 New Guest Casita Conditioned AC-22 1100 10 DHW Sys 1 New Living Area Conditioned AC-3 & 43 3276 12 DHW Sys 1 New Second Floor Conditioned AC-54 1246 9 DHW Sys 1 New 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 6 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) NE Wall Master Suite R-21 Wall 45 Front 30 0 90 SE Wall Master Suite R-21 Wall 135 Left 120 10.8 90 SW Wall Master Suite R-21 Wall 225 Back 324 149.6 90 300d Wall Master Suite R-21 Wall 300 n/a 60 34.4 90 NW Wall Master Suite R-21 Wall 315 Right 472 50.2 90 NE Wall 2 Guest Casita R-21 Wall 45 Front 390 118.3 90 SE Wall 2 Guest Casita R-21 Wall 135 Left 330 135 90 SW Wall 2 Guest Casita R-21 Wall 225 Back 180 89 90 NW Wall 2 Guest Casita R-21 Wall 315 Right 330 18.9 90 NE Wall 3 Living Area R-21 Wall 45 Front 649 164 90 SE Wall 3 Living Area R-21 Wall 135 Left 1248 196.5 90 SW Wall 3 Living Area R-21 Wall 225 Back 636 360 90 NW Wall 3 Living Area R-21 Wall 315 Right 612 418.01 90 NE Wall 4 Second Floor R-21 Wall 45 Front 288 60 90 SE Wall 4 Second Floor R-21 Wall 135 Left 486 45 90 SW Wall 4 Second Floor R-21 Wall 225 Back 288 117 90 NW Wall 4 Second Floor R-21 Wall 315 Right 486 44 90 Roof Master Suite R-38/ R19 vented n/a n/a 1006 n/a n/a Roof 2 Guest Casita R-38/ R19 vented n/a n/a 1100 n/a n/a Roof 3 Living Area R-38/ R19 vented n/a n/a 3276 n/a n/a Roof 4 Second Floor R-38/ R19 vented n/a n/a 1246 n/a n/a Raised Floor Second Floor R-19 Floor (F.19.2x8.16)n/a n/a 1246 n/a n/a 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 7 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Suite Attic RoofMaster Suite Ventilated 3 0.61 0.88 No Yes Attic Guest Casita Attic RoofGuest Casita Ventilated 3 0.61 0.88 No Yes Attic Living Area Attic RoofLiving Area Ventilated 3 0.61 0.88 No Yes Attic Second Floor Attic RoofSecond Floor Ventilated 3 0.61 0.88 No Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading C Window SE Wall Left 135 1 3.6 0.34 NFRC 0.23 NFRC Bug Screen C 2 Window SE Wall Left 135 1 3.6 0.34 NFRC 0.23 NFRC Bug Screen C 3 Window SE Wall Left 135 1 3.6 0.34 NFRC 0.23 NFRC Bug Screen 4 Window SW Wall Back 225 12 10 1 120 0.4 NFRC 0.21 NFRC Bug Screen E2 Window SW Wall Back 225 1 29.6 0.34 NFRC 0.23 NFRC Bug Screen E Window 300d Wall 300 1 6.4 0.34 NFRC 0.23 NFRC Bug Screen E1 Window 300d Wall 300 1 28 0.34 NFRC 0.23 NFRC Bug Screen D1 Window NW Wall Right 315 1 6.2 0.34 NFRC 0.23 NFRC Bug Screen D Window NW Wall Right 315 1 44 0.34 NFRC 0.23 NFRC Bug Screen GE Window NE Wall 2 Front 45 1 6.3 0.34 NFRC 0.23 NFRC Bug Screen GD Window NE Wall 2 Front 45 1 56 0.36 NFRC 0.18 NFRC Bug Screen GC Window NE Wall 2 Front 45 1 56 0.34 NFRC 0.23 NFRC Bug Screen 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 8 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading GB1 Window SE Wall 2 Left 135 1 55 0.34 NFRC 0.24 NFRC Bug Screen 2 Window SE Wall 2 Left 135 1 80 0.4 NFRC 0.21 NFRC Bug Screen GB Window SW Wall 2 Back 225 1 33 0.34 NFRC 0.23 NFRC Bug Screen 12 Window SW Wall 2 Back 225 1 30 0.41 NFRC 0.24 NFRC Bug Screen GA Window SW Wall 2 Back 225 1 26 0.41 NFRC 0.24 NFRC Bug Screen GF Window NW Wall 2 Right 315 1 6.3 0.34 NFRC 0.23 NFRC Bug Screen GF 2 Window NW Wall 2 Right 315 1 6.3 0.34 NFRC 0.23 NFRC Bug Screen GF 3 Window NW Wall 2 Right 315 1 6.3 0.34 NFRC 0.23 NFRC Bug Screen B1 Window NE Wall 3 Front 45 1 68 0.34 NFRC 0.23 NFRC Bug Screen A Window NE Wall 3 Front 45 1 23 0.34 NFRC 0.23 NFRC Bug Screen 1 Window NE Wall 3 Front 45 5 10 1 50 0.34 NFRC 0.24 NFRC Bug Screen M1 Window NE Wall 3 Front 45 1 23 0.34 NFRC 0.23 NFRC Bug Screen B Window SE Wall 3 Left 135 1 50 0.34 NFRC 0.23 NFRC Bug Screen H Window SE Wall 3 Left 135 1 32.5 0.36 NFRC 0.18 NFRC Bug Screen G Window SE Wall 3 Left 135 1 18 0.34 NFRC 0.23 NFRC Bug Screen 8 Window SE Wall 3 Left 135 1 24 0.38 NFRC 0.2 NFRC Bug Screen F Window SE Wall 3 Left 135 1 12 0.34 NFRC 0.23 NFRC Bug Screen F1 Window SE Wall 3 Left 135 6 2 1 12 0.34 NFRC 0.23 NFRC Bug Screen 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 9 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading F 2 Window SE Wall 3 Left 135 6 2 1 12 0.34 NFRC 0.23 NFRC Bug Screen F1 2 Window SE Wall 3 Left 135 6 2 1 12 0.34 NFRC 0.23 NFRC Bug Screen 7 Window SE Wall 3 Left 135 6 2 2 24 0.38 NFRC 0.2 NFRC Bug Screen 6 Window SW Wall 3 Back 225 24 10 1 240 0.4 NFRC 0.21 NFRC Bug Screen 4 2 Window SW Wall 3 Back 225 12 10 1 120 0.4 NFRC 0.21 NFRC Bug Screen 5 Window NW Wall 3 Right 315 17.5 10 1 175 0.4 NFRC 0.21 NFRC Bug Screen M Window NW Wall 3 Right 315 1 90 0.34 NFRC 0.23 NFRC Bug Screen L Window NW Wall 3 Right 315 10.7 14.3 1 153.0 1 0.34 NFRC 0.24 NFRC Bug Screen 2F Window NE Wall 4 Front 45 1 40 0.36 NFRC 0.18 NFRC Bug Screen 2F1 Window NE Wall 4 Front 45 1 20 0.36 NFRC 0.18 NFRC Bug Screen 2E Window SE Wall 4 Left 135 1 8 0.34 NFRC 0.23 NFRC Bug Screen 2D Window SE Wall 4 Left 135 1 4 0.34 NFRC 0.23 NFRC Bug Screen 2D 2 Window SE Wall 4 Left 135 1 4 0.34 NFRC 0.23 NFRC Bug Screen 2D 3 Window SE Wall 4 Left 135 1 4 0.34 NFRC 0.23 NFRC Bug Screen 2C Window SE Wall 4 Left 135 1 12.5 0.36 NFRC 0.18 NFRC Bug Screen 2C 2 Window SE Wall 4 Left 135 1 12.5 0.36 NFRC 0.18 NFRC Bug Screen 2B Window SW Wall 4 Back 225 1 9 0.34 NFRC 0.23 NFRC Bug Screen 13 Window SW Wall 4 Back 225 1 108 0.4 NFRC 0.21 NFRC Bug Screen 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 10 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading 2A Window NW Wall 4 Right 315 1 20 0.34 NFRC 0.23 NFRC Bug Screen 2G Window NW Wall 4 Right 315 1 24 0.34 NFRC 0.23 NFRC Bug Screen OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 4 20 0.1 20 20 0 0 0 0 0 0 0 0 0 1 3 0.1 3 3 0 0 0 0 0 0 0 0 0 F1 3 0.1 3 3 0 0 0 0 0 0 0 0 0 F 2 3 0.1 3 3 0 0 0 0 0 0 0 0 0 F1 2 3 0.1 3 3 0 0 0 0 0 0 0 0 0 7 3 0.1 3 3 0 0 0 0 0 0 0 0 0 6 14 0.1 14 14 0 0 0 0 0 0 0 0 0 4 2 22 0.1 22 22 0 0 0 0 0 0 0 0 0 5 22 0.1 22 22 0 0 0 0 0 0 0 0 0 L 2 0.1 2 2 0 0 0 0 0 0 0 0 0 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 11 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab Master Suite 1006 92 none 0 80%No Slab 2 Guest Casita 1100 126 none 0 80%No Slab 3 Living Area 3276 259 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Attic RoofMaster Suite Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Attic RoofGuest Casita Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Attic RoofLiving Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 12 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofSecond Floor Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. R-19 Floor (F.19.2x8.16) Floors Over Crawlspace Wood Framed Floor 2x8 @ 16 in. O. C.R-19 None / None 0.047 Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking Cavity / Frame: R-19 / 2x8 R-38/ R19 vented Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) Standard DHW Heater 1 2 n/a Expanded DHW Sys 1-hers-dhw DHW Heater 1 (2) 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 13 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal) NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 2 80 A. O. Smith HPS10-80H45DV 2** (80 gal, JA13) Outside Living Area Living Area WATER HEATING - COMPACT DISTRIBUTION 01 02 03 04 05 06 07 Dwelling Unit type Water Heating System Name Master Bath distance of furthest fixture to Water Heater (ft) Kitchen distance of furthest fixture to Water Heater (ft) Furthest Third furthest fixture to Water Heater (ft) Compactness Factor HERS Verification Dwelling DHW Sys 1 n/a n/a n/a 0.6 Expanded Credit WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Required Expanded Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type AC-11 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback AC-22 Heat pump heating cooling Heat Pump System 2 1 Heat Pump System 2 1 HVAC Fan 2 Air Distribution System 2 Setback AC-3 & 43 Heat pump heating cooling Heat Pump System 3 2 Heat Pump System 3 2 HVAC Fan 3 Air Distribution System 3 Setback 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 14 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type AC-54 Heat pump heating cooling Heat Pump System 4 1 Heat Pump System 4 1 HVAC Fan 4 Air Distribution System 4 Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification Heating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF 10 47000 30550 EERSEER 18 13 Not Zonal Single Speed Heat Pump System 1-hers-htpump Heat Pump System 2 Central split HP 1 HSPF 10 47000 30550 EERSEER 18 13 Not Zonal Single Speed Heat Pump System 2-hers-htpump Heat Pump System 3 Central split HP 2 HSPF 10 55500 36075 EERSEER 18 13 Not Zonal Single Speed Heat Pump System 3-hers-htpump Heat Pump System 4 Central split HP 1 HSPF 10 55500 36075 EERSEER 18 13 Not Zonal Single Speed Heat Pump System 4-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 2-hers-htpump Required 350 Required Required Yes Yes Yes Yes 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 15 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 3-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 4-hers-htpump Required 350 Required Required Yes Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist Air Distribution System 2 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 2-hers-dist Air Distribution System 3 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 3-hers-dist Air Distribution System 4 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 4-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 16 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 2-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 3-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 4-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.35 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.35 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.35 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.35 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.35 HVAC Fan 2-hers-fan Required 0.35 HVAC Fan 3-hers-fan Required 0.35 HVAC Fan 4-hers-fan Required 0.35 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 17 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display? HERS Verification Status SFam IAQVentRpt 216 0.35 Exhaust No n/a / n/a No Yes 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Hideaway 309 Calculation Date/Time:2024-01-22T15:53:35-08:00 (Page 18 of 18) Calculation Description:Title 24 Analysis Input File Name:Hideaway Lot 309-Fedderly-23.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-01-22   15:55:41 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Tim Scott Scott Design and Title 24, Inc. 77085 Michigan Dr. Palm Desert, CA 92211 2024-01-22 15:58:30 760-200-4780 Tim Scott Scott Design and Title 24, Inc. 77085 Michigan Dr. Palm Desert, CA 92211 2024-01-22 15:58:30 na 760-200-4780 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 224-P010009872A-000-000-0000000-0000 2024-01-22 15:58:30 CalCERTS inc.