Andalusia TR 31681-3 BCPR2020-0001 (Plan 24 & 25) 2019 Code Update!� ylProject Details PROJECT NUMBER
Cit of La Quinta
BCPR2020-0001
Description: ANDALUSIA / 2019 CODE UPDATE / PLAN 24, 25
Status: APPROVED
Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB)
Status Date: 4/14/2020
Subtype: TRACT RESIDENTIAL
Applied: 1/24/2020
Address: 59000 MADISON ST
Approved:
City, State, Zip: LA QUINTA,CA92253
Closed:
Project Manager:
Expired:
Details: CODE UPDATE FOR 4184 SF DWELLING - PLAN 24 AND 4502 SF DWELLING - PLAN 25
[VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK
WALLS OR DRIVEWAY APPROACH. 2019 CALIFORNIA BUILDING CODES.
DAYS
REVIEWS
ACTIONS
INSPECTIONS
CONDITIONS
CASE OPEN
OPEN
COMPLETED
A 1 9 •
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
COUNTER VISIT
AARON HICKSON
1/27/2020
1/27/2020
LOWERED PLAN CHECK PER AJ
NOTE
AARON HICKSON
2/18/2020
2/18/2020
PLAN CHECK RECEIVED FROM INTERWEST REVISIONS
REQUIRED
EMAIL
DUANE CLAYTON
3/4/2020
3/4/2020
- INFORMED APPLICANT THAT PLANS REQUIRE REVISIONS.
- OBTAIN CORRECT INTERWEST COMMENT LIST FOR PLANS
NOTE
DUANE CLAYTON
3/4/2020
3/5/2020
24 AND 25. ATTACH IN TRAKIT AND INFORM APPLICANT
THAT REVISIONS TO PLANS ARE REQUIRED.
BY NOLAN SPARKS
APPLICANT DID NOT PICK UP CITY CORRECTION LIST SINCE IT
1ST PC PICKED UP
AARON HICKSON
3/5/2020
3/5/2020
WAS INCORRECT. DUANE WILL SEND APPLICANT CORRECT
CORRECTION LIST BY EMAIL. WE WERE UNABLE TO VERIFY
ITEMS THAT WERE SUPPOSE TO BE GIVEN BACK TO
APPLICANT.
Printed: Wednesday, December 20, 2023 10:27:52 AM 1 of 7 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2020-0001
EMAIL
DUANE CLAYTON
3/5/2020
3/5/2020
- SENT CITY AND CONSULTANT CORRECTION LISTS TO
APPLICANT VIA EMAIL.
EMAIL
DUANE CLAYTON
3/5/2020
3/5/2020
- INFORMED APPLICANT THAT PLAN REVIEW IS COMPLETE
AND REQUIRES REVISIONS.
EMAIL
DUANE CLAYTON
4/23/2020
4/23/2020
- INFORMED APPLICANT THAT PLANS ARE APPROVED.
DEPOSIT OF $750 WHICH WAS NOT USED WILL BE REFUNDED
NOTE
ARMANDO MAGALLON
2/24/2021
2/24/2021
BACK TO APPLICANT. REFUND CANNOT BE REFUNDED BACK
TO APPLICANT VIA CREDIT DUE TO HOW OLD IT IS. CHECK
REQUEST WILL BE NEEDED.
NOTE
LORI LORETT
3/8/2021
3/8/2021
REFUND PROCESSED FOR $750.00, CHECK MAILED 3/5/2021.
REFUND HAS BEEN COMPLETED - THE MONEY HAD NOT BEEN
MOVED OVER FROM ACOUNT 42600 TO 42300 ON THE
NOTE
ARMANDO MAGALLON
3/10/2021
3/10/2021
FINANCIAL SIDE. THE REFUND WAS COMPLETED FROM
ACCOUNT 42600 FOR THE FINANCIAL SIDE BUT FROM 42300
FROM THE TRAKIT SIDE.
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE FAX
EMAIL
APPLICANT
NOLAN SPARKS / SUNRISE LQ, LLC
81570 CARBONERAS
LA QUINTA
CA
92253
NSPARKS@RANCHOLA
QUINTA.COM
CONTRACTOR
NATIONAL MORTGAGE & LAND
300 EAGLE DANCE
PALM DESERT
CA
92211
COMPANY
CIRCLE
OWNER
T D DESERT DEV
81570 CARBONERAS
LA QUINTA
CA
0
NCIAL
INFORMFIN
•�
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
NATIONAL
HOURLY CHARGE - CITY
101-0000-42600
2
$322.00
$322.00
4/23/20
WEB4959
CREDIT
MORTGAGE & LAND
ECON
BUILDING STAFF
CO M PA
Printed: Wednesday, December 20, 2023 10:27:52 AM 2 of 7 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2020-0001
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
HOURLY CHARGE -
NATIONAL
INTERWEST PLANS
101-0000-42600
3
$300.00
$300.00
4/23/20
WEB4959
CREDIT
MORTGAGE & LAND
ECON
EXAMINER
COMPA
HOURLY CHARGE -
NATIONAL
INTERWEST
101-0000-42600
4
$500.00
$500.00
4/23/20
WEB4959
CREDIT
MORTGAGE & LAND
ECON
STRUCTURAL PLAN
COMPA
REVIEW
Total Paid for BUILDING STAFF - PER HOUR: $1,122.00 $1,122.00
BUILDING TRACT
RESIDENTIAL
101-0000-42600
1
$750.00
$750.00
1/24/20
MR829
867270
CREDIT
NOLAN SPARKS
AHI
CONSTRUCTION PLAN
CARD
DEPOSIT
Total Paid for BUILDING TRACT RESIDENTIAL
$750.00 $750.00
CONSTRUCTION PLAN DEPOSIT:
101-0000-42600
($750.00)
($750.00)
2/24/21
OFFSET
OFFSET
AMA
CASH OVER
101-0000-42300
0
$750.00
$750.00
2/24/21
DEPOSIT
DEPOSIT
AMA
Total Paid for CASH OVER: $0.00 $0.00
RECORDS
NATIONAL
MANAGEMENT FEE -
101-0000-42416
0
$21.00
$21.00
4/14/20
WEB4889
CREDIT
MORTGAGE & LAND
ECON
MAJOR
COMPA
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
REFUND / UNUSED
101-0000-42300
0
($750.00)
($750.00)
3/7/21
R64171
204223
CHECK
NOLAN SPARKS
AMA
DEPOSIT
Total Paid for REFUND / UNUSED DEPOSIT: ($750.00) ($750.00)
NATIONAL
TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
4/14/20
WEB4889
CREDIT
MORTGAGE & LAND
ECON
ENHANCEMENT FEE
COMPA
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
Printed: Wednesday, December 20, 2023 10:27:52 AM 3 of 7 CENTRALSQUARE
Project Details PROJECT NUMBER
City of La Quinta BCPR2020-0001
•
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS
NOTES
RETURNED
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
STATUS
REMARKS
NOTES
DATE
1ST BLDG
INTERWEST
1/24/2020
2/14/2020
2/17/2020
REVISIONS REQUIRED
PC1 plans to be delivered via GSO Tracking #
COMPLETE (3WK)
547991435.
1ST BLDG NS (3WK)
DUANE
1/24/2020
2/14/2020
3/4/2020
REVISIONS REQUIRED
- SEE 1ST REVIEW NS AND STR CORRECTIONS IN
CLAYTO N
ATTACHMENTS.
1ST FIRE (2WK)
KOHL
1/24/2020
2/7/2020
2/18/2020
NOT REQUIRED
HETRICK
1ST PLANNING
CARLOS
1/24/2020
2/7/2020
2/6/2020
READY FOR APPROVAL
(2WK)
FLORES
1ST PUBLIC WORKS
AMY YU
1/24/2020
2/7/2020
2/6/2020
READY FOR APPROVAL
FOOTPRINT NOT CHANGED PER NOLAN
(2WK)
2ND BLDG
INTERWEST
4/14/2020
4/28/2020
4/22/2020
APPROVED
DIGITAL RESUBMITTAL. PLEASE SEE 2ND
COMPLETE (2WK)
SUBMITTAL DOCUMENTS IN ATTACHMENTS.
2ND BLDG NS (2WK)
DUANE
4/14/2020
4/28/2020
4/23/2020
APPROVED
- SEE APPROVED PLAN AND DOCUMENTS IN
CLAYTO N
ATTACHMENTS.
11
1w
Attachment Type
CREATED
OWNER DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
59000 MADISON - 1ST
1ST REVIEW
DOC
3/5/2020
DUANE CLAYTON CORRECTION LIST - CITY
REVIEW CORRECTION
0
LIST - CITY OF LA-
OF LA-QUINTA
QUINTA.pdf
Printed: Wednesday, December 20, 2023 10:27:52 AM 4 of 7 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2020-0001
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
59000 MADISON
APPROVED-
(BCPR2020-0001) -
DOC
4/23/2020
DUANE CLAYTON
ARCHITECTURAL
APPROVED-
1
DRAWINGS - PLANS 24
ARCHITECTURAL
AND 25
DRAWINGS - PLANS 24
AND 25.pdf
59000 MADISON
DOC
4/23/2020
DUANE CLAYTON
APPROVED -ENERGY
APB ROVED - ENERGY
1
DOCUMENTS -PLAN 24
DOCUMENTS - PLAN
24.pdf
59000 MADISON
(BCPR2020-0001) -
DOC
4/23/2020
DUANE CLAYTON
APPROVED -ENERGY
APPROVED -ENERGY
1
DOCUMENTS -PLAN 25
DOCUMENTS - PLAN
25.pdf
59000 MADISON
APPROVED-
(BCPR2020-0001) -
DOC
4/23/2020
DUANE CLAYTON
STRUCTURAL
APPROVED -
CALCULATIONS - PLAN
STRUCTURAL
24
CALCULATIONS - PLAN
24.pdf
59000 MADISON
APPROVED-
(BCPR2020-0001) -
DOC
4/23/2020
DUANE CLAYTON
STRUCTURAL
APPROVED -
CALCULATIONS - PLAN
STRUCTURAL
25
CALCULATIONS - PLAN
25.pdf
59000 MADISON
DOC
4/23/2020
DUANE CLAYTON
APPROVED - TRUSS
(BCPR2020-0001) -
1
PACKAGE - PLAN 24
APPROVED - TRUSS
PACKAGE - PLAN 24.pdf
Printed: Wednesday, December 20, 2023 10:27:52 AM 5 of 7 CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2020-0001
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
59000 MADISON
DOC
4/23/2020
DUANE CLAYTON
APPROVED - TRUSS
(BCPR2020-0001) -
1
PACKAGE - PLAN 25
APPROVED - TRUSS
PACKAGE - PLAN 25.pdf
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL - TITLE
plan 25_T-24 Calcs.pdf
1
24 (PLAN 25)
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL - TITLE
Plan 24_T-24 Calcs.pdf
1
24 (PLAN 24)
2ND SUBMITTAL -
DOC
4/14/2020
EtrakitContractor
STRUCTURAL CALS
Plan 24 str Calcs.pdf
1
(PLAN 24)
2ND SUBMITTAL -
DOC
4/14/2020
EtrakitContractor
STRUCTURAL CALCS
Plan 25 Str Calcs.pdf
1
(PLAN 25)
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL - ENG
Plan 24 and 25 Str
1
RESPONSE
Response.pdf
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL - ARC
Plan 24 and 25 Arch
1
RESPONSE
Response.pdf
Plan 24 and 25_2nd
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL - PLAN
Submittal Set 3-27-
1
SET (PLANS 24, 25)
20.pdf
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL -
Plan 24 Trusses.pdf
1
TRUSS CALC (PLAN 24)
DOC
4/14/2020
EtrakitContractor
2ND SUBMITTAL -
Plan 25 Trusses.pdf
1
TRUSS CALCS (PLAN 25)
La Quinta - 202000965;
La Quinta - 202000965;
DOC
2/17/2020
INTERWEST
BCPP2020-0001-
BCPP2020-0001-
0
Invoice 57373.pdf
Invoice 57373.pdf
DOC
3/5/2020
INTERWEST
202000965(BCPP2020-
202000965(BCPP2020-
0
0001) -1 PC1.docx
0001) -1 PC1.docx
Printed: Wednesday, December 20, 2023 10:27:52 AM 6 of 7 ;• CENTRALSQUARE
!� ylProject Details PROJECT NUMBER
City of La Quinta BCPR2020-0001
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/22/2020
INTERWEST
202000965(BCP2020-
202000965(BCP2020-
0
001) PCF.docx
001) PCF.docx
La Quinta - 202000965;
La Quinta - 202000965;
DOC
4/22/2020
INTERWEST
BCPP2020-0001-
BCPP2020-0001-
0
Invoice 59284.pdf
Invoice 59284.pdf
REFUND BCPR2020-
REFUND BCPR2020-
DOC
3/8/2021
LORI LORETT
0001 Nolan Sparks
0001 Nolan Sparks
0
02.25.21
02.25.21.pdf
Printed: Wednesday, December 20, 2023 10:27:52 AM 7 of 7 CENTRALSQUARE
Invoice No.: 57373
Invoice Date: 2/17/2020
Jurisdiction No.: BCPP2020-0001
Interwest Job No.: 202000965
INTERWEST CONSULTING GROUP
Remit to:
Interwest Consulting Group
P.O. Box 18330
Boulder, CO 80308
Direct questions to:
Malia Aipia Powers (916) 512-6812
maipiapowers @interwestgrp. com
Residential - Andalusia Country Club - Plan 22
59000 Madison
Professional Services for the Period February 1 through February 17. 2020
Bill to:
City of La Quinta
Attention James "JW" Wiatrak, Building Official
78-495 Calle Tampico
La Quinta, CA 92253
Project
Hours Total
Invoice Total 13 $350.00
Person Title Week End Hours Rate Total
Bryan Montes
Plan Check Engineer
2/14/2020
2
$125.00
$250.00
Adrienne Peterson
ICC Certified Plans
Examiner
2/14/2020
1
$100.00
$100.00
Labor
3
$350.00
2018-05-09 Rev.1
Sent to Finance 02.25.21
DEMAND / CHECK REQUEST
--J L-- Return check to requestor --- U Mail check
Name / Title of person requesting check
Lori Lorett / Permit Technician
Department individual is associated with:
Design & Development
Check payable to:
Nolan Sparks 750.00
Name Amount: $ _
(Name) (Vendor No.)
81570 Carboneras _ Account Number: 101-0000-42300
(Address) -
La Quinta, CA 92253 BCPR2020-0001
— — Project Number:
Check description and invoice number:
Refund for unused deposit on permit.
APPROVED FOR PAYMENT
(Finance Department Use Only)
BY:
Signat -_
BY: -
(Department Head)
02.25.2021
(Date)
ACCOUNT NO...
DESCRIPTION
Check mailed 03.05.21 L.L.
City of La Quinta
VENDOR: 09961 SPARKS, NOLAN
DATE ID PO # DESCRIPTION
2/25/2021 022521 02/25/21 - PERMIT DEPOSIT REFUND BCPR2020-0001
PAY
TO THE
ORDER
OF
City of La Quinta BANK OF THE WEST
78-495 Calle Tampico 90-78/ 1211
La Quinta, CA 92253
��llil�
�•
N- - � r!
---Seven Hundred Fifty Dollars and 00/100 Cents--, �r
_. 7.
SPARKS, KI I AN - %~
ati^ "Y �.
81570 CARBONERAS C,
LA QUINTA, CA 92253-
U 1-
CHECK NO: 204223
03/05/2021
GL ACCT # AMOUNT
101-0000-42600 750.00
CHECK TOTAL 75000
CHECK NO: 204223
03/05/2021
pAY THIS AMOUNT
THIS CHECK EXPIRES AND IS VOID 180 DAYS FROM ISSUE DATE
AUT ORIZED SIGNATURE
���
AUTHORIZED SIGNATURE
11' 20t, 2 230 1: 1 2 110078 21: 0059731851118
C uP"zCaD-c)vo
DEPOSIT WAS NOT USED AND HAS BEEN DEPOSITED TO THE CASHOVER ACCOUNT, WHICH WILL BE
REFUNED BACK TO APPLICANT. THE AMOUNT TO BE REFUNDED IS $750.
Financial Information
Add I p:E- ReceiptsLIE]l DepoE Irn Ec Unpay
Description Qty Amount Comments Paid Receipt In
BUILDING TRACT RESIDENTIAL 01/24/20
CONSTRUCTION PLAN DEPOSIT $750.00 CREDIT MR829
101-0000-42600 CARD
TECHNOLOGY ENHANCEMENT FEE $5 00 0-1i11i20 g
502-0000-45611 1hEB,3
CREDIT
RECORDS MANAGEMENT FEE - MAJOR S21.00 04j" /"0 WEBeo$9
101-0000-42416 CREDIT
BUILDING STAFF -PER HOUR
-a CASH OVER
101-0000-42300
t
Inspections (0)
.Add Inspection 11 Add Calendar 11 Set Setluence
S1,122.00
$750.00 DEPOSIT REFUND ;SEE NOTES)
be fe�uviJed
79„ Ce-pried: S1,89l.00
(� Dtm : u $0.00
0-i23/20 WE64959
--REOIT
02i%1121 DEPOSIT
EPOSIT
Paid: $1,898,00
Due: $0.00
DESCRIPTION ACCOUNTQTYPAID
PermitTRAK $176.00
FSS2020-0014 Address: 81730 ANDALUSIA Apn: 764670006 $176.00
FIRE FEES $161.00
FIRE SPRINKLER SYSTEMS -SINGLE FAMILY
DETACHED
101-0000-42421
0
$161.00
RECORDS MANAGEMENT FEE $10.00
RECORDS MANAGEMENT FEE 101-0000-42416
0
$10.00
TECHNOLOGY ENHANCEMENT FEE $5.00
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0
$5.00
ProjectTRAK $3,000.00
BCPR2020-0001 Address: 59000 MADISON ST Apn: 764700011 $750.00
BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00
BUILDING TRACT RESIDENTIAL 101-0000-42600 1 $750.00
CONSTRUCTION PLAN DEPOSIT
BCPR2020-0002 Address: 59000 MADISON ST Apn: 764700011 $750.00
BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00
BUILDING TRACT RESIDENTIAL 101-0000-42600 1 $750.00
CONSTRUCTION PLAN DEPOSIT
BCPR2020-0003 Address: 59000 MADISON ST Apn: 764700011 $750.00
BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00
BUILDING TRACT RESIDENTIAL
CONSTRUCTION PLAN DEPOSIT 101-0000-42600
1
$750.00
BCPR2020-0004 Address: 59000 MADISON ST Apn: 764700011 $750.00
BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00
BUILDING TRACT RESIDENTIAL
CONSTRUCTION PLAN DEPOSIT 101-0000-42600 1 $750.00
• 1 1
Date Paid: Friday, January 24, 2020
Paid By: NOLAN SPARKS
Cashier: AHI
Pay Method: CREDIT CARD 867270
Printed: Thursday, February 25, 20219:12 AM 1 of 1 hub:
BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
PLAN # 24
59000 MADISON ANDALUSIA C.C.
LA QUINTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528
Report Prepared by:
TITLE 24 OF THE DESERT SERVICES INC.
title24ofthedesert@gmail.com
760 278.1840,
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
04/23/2020 �—D C
Job Number:
20 - GLS /001 - 002 - 2R
Date:
3/19/2020
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
1
Table of Contents
2
Form CF1 R-PRF-01-E Certificate of Compliance
3
Form RMS-1 Residential Measures Summary
20
HVAC System Heating and Cooling Loads Summary
22
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 1 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
GENERAL INFORMATION
01
Project Name
PLAN 24 ANDALUSIA
02
Run Title
Title 24 Analysis
03
Project Location
59000 MADISON ANDALUSIA C.C.
04
City
LA QUINTA
05
Standards Version
2019
06
Zip code
92270
07
Software Version
EnergyPro 8.0
08
Climate Zone
15
09
Front Orientation (deg/ Cardinal)
AIIOrientations
10
Building Type
SingleFamily
11
Number of Dwelling Units
1
12
Project Scope
NewConstruction
13
Number of Bedrooms
4
14
New Cond. Floor Area (ft)
0
15
Number of Stories
1
16
Existing Cond. Floor Area (ft)
n/a
17
Fenestration Average U-factor
0.29
18
Total Cond. Floor Area (ftZ)
4184
19
Glazing Percentage (%)
23.77%
20
ADU Bedroom Count
0
21
ADU Conditioned Floor Area
0
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 2 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency' (EDR)
TotalZ (EDR)
Efficiency' (EDR)
TotalZ (EDR)
Standard Design
46.1
23
Proposed Designs
North Facing
43.6
20.6
2.5
2.4
East Facing
44.1
21
2
2
South Facing
41
17.9
5.1
5.1
West Facing
44.9
21.9
1.2
1.1
RESULT: 3: COMPLIES ►
Efficiency EDR includes improvements to the building envelope and more efficient equipment
Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc.
s Building complies when efficiency and total compliance margins are greater than or equal to zero
• Standard Design PV Capacity: 7.09 kWdc
• Proposed PV Capacity Scaling: North (7.09 kWdc) East (7.09 kWdc) South (7.09 kWdc) West (7.09 kWdc)
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 3 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
ENERGY USE SUMMARY
Energy Use (kTDWft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.67
2.9
-1.23
-73.7
Space Cooling
81.83
73.08
8.75
10.7
IAQ Ventilation
2.19
2.19
0
0
Water Heating
5.1
6.15
-1.05
-20.6
Self Utilization Credit
n/a
0
0
n/a
North Facing Compliance Total
90.79
84.32
6.47
7.1
Space Heating
1.67
3.37
-1.7
-101.8
Space Cooling
81.83
73.76
8.07
9.9
IAQ Ventilation
2.19
2.19
0
0
Water Heating
5.1
6.15
-1.05
-20.6
Self Utilization Credit
n/a
0
0
n/a
East Facing Compliance Total
90.79 rftr:DT
85.47
5.32
5.9
Space Heating
1.67
2.32
-0.65
-38.9
Space Cooling
81.83 S P R 66.63
15.2
18.6
IAQ Ventilation
2.19
2.19
0
0
Water Heating
5.1
6.15
-1.05
-20.6
Self Utilization Credit
n/a
0
0
n/a
South Facing Compliance Total
90.79
77.29
13.5
14.9
Space Heating
1.67
2.48
-0.81
-48.5
Space Cooling
81.83
76.95
4.88
6
IAQ Ventilation
2.19
2.19
0
0
Water Heating
5.1
6.15
-1.05
-20.6
Self Utilization Credit
n/a
0
0
n/a
West Facing Compliance Total
90.79
87.77
3.02
3.3
REQUIRED PV SYSTEMS
01 02 03 04 05 06 1 07 1 08 09 10 11
Registration Number: Registration Date/Time: HERS Provider:
220-P010012257B-000-000-0000000-0000 2020-03-19 11:59:55 CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 4 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
DC System Size
Exception
Module Type
Array Type
Power Electronics
CFI
Azimuth
Tilt
Array Angle
Tilt: (x in 12)
Inverter Eff.
(kWdc)
(deg)
Input
(deg)
N
7.09
NA
Standard
Fixed (roof
none
true
n/a
n/a
n/a
n/a
96
mount)
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• PV System: 7.09 kWdc
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• Quality insulation installation (QII)
• Indoor air quality ventilation
• Kitchen range hood i InL.
Cooling System Verifications: CaICERTS,
• Minimum Airflow
• Verified EER Ilk H E R S P R O V I D E R
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
Heating System Verifications:
• Verified HSPF
• Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
• Duct leakage testing
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
z
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
PLAN 24 ANDALUSIA
4184
1
4
4
0
1
Registration Number: Registration Date/Time: HERS Provider:
220-P010012257B-000-000-0000000-0000 2020-03-19 11:59:55 CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 5 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ftz)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
Z1- 1655
Conditioned
AC-1 -1
1655
10
DHW Sys 1
N/A
Z2 - 1523
Conditioned
AC-2 -2
1523
10
DHW Sys 1
N/A
Z3 - 479
Conditioned
AC-3 -3
479
10
DHW Sys 1
N/A
Z4 - 527
Conditioned
AC-4 -4
527
10
DHW Sys 1
N/A
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
N - 802
Z1- 1655
R-21 Wall
0
Front
802
80.5
90
E - 240
Z1- 1655
R-21 Wall
180
Back
240
14.436
90
S - 205
Z1- 1655
R-21 Wall
180
Back
205
72
90
W -240
Z1- 1655
R-21 Wall
270
Right
240
96
90
N - 175
Z2 - 1523
R-21 Wall
0
Front
175
126
90
E - 106
Z2 - 1523
R-21 Wall
180
Back
106
24
90
S - 487
Z2 - 1523
R-21 Wall
180
Back
487
55.5
90
W - 409
Z2 - 1523
R-21 Wall
270
Right
409
332
90
N - 122
Z3 - 479
R-21 Wall
0
Front
122
103.996
90
E - 65
Z3 - 479
R-21 Wall
90
Left
65
4.5
90
S - 173
Z3 - 479
R-21 Wall
180
Back
173
4.5
90
N - 253
Z4 - 527
R-21 Wall
0
Front
253
9
90
W - 204
Z4 - 527
R-21 Wall
270
Right
204
72
90
1655
Z1-1655
R-38 + R-21-
n/a
n/a
1655
n/a
n/a
1523
Z2 - 1523
R-38 + R-21
n/a
n/a
1523
n/a
n/a
479
Z3 - 479
R-38 + R-21
n/a
n/a
479
n/a
n/a
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 6 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
527
Z4 - 527
R-38 + R-21 --
n/a
n/a
527
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Z1- 1655
Attic RoofZ1- 1655
Ventilated
4
0.1
0.85
No
No
Attic Z2 - 1523
Attic RoofZ2 - 1523
Ventilated
4
0.1
0.85
No
No
Attic Z3 - 479
Attic RoofZ3 - 479
Ventilated
4
0.1
0.85
No
No
Attic Z4 - 527
Attic RoofZ4 - 527
Ventilated
4
0.1
0.85
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
Mult.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
a
Exterior
Shading
2056 - 21
Window
N - 802
Front
0
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
2056 - 22
Window
N - 802
Front
0
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 23
Window
N - 802
Front
0
3
5.5
1
16.5
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 24
Window
N - 802
Front
0
3
5.5
1
16.5
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 25
Window
N - 802
Front
0
3
5.5
1
16.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 26
Window
N - 802
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 27
Window
N - 802
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
2050 - 28
Window
E - 240
Back
180
12
12
0
9.94
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 29
Window
E - 240
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
9080 - 30
Window
S - 205
Back
180
9
8
1
72
0.29
NFRC
0.2
NFRC
Bug Screen
12080 - 31
Window
W - 240
Right
270
12
8
1
96
0.29
NFRC
0.2
NFRC
Bug Screen
1061200 - 10
Window
N - 175
Front
0
10.5
12
1
126
0.29
NFRC
0.2
NFRC
Bug Screen
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 7 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MuIt.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
a
Exterior
Shading
3080 - 7
Window
E - 106
Back
180
3
8
1
24
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 15
Window
S - 487
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 14
Window
S - 487
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 13
Window
S - 487
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 11
Window
S - 487
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 12
Window
S - 487
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 17
Window
S - 487
Back
180
3
5.5
1
16.5
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 18
Window
S - 487
Back
180
3
5.5
1
16.5
0.29
NFRC
0.2
NFRC
Bug Screen
80100 - 19
Window
W - 409
Right
270
8
10
1
80
0.29
NFRC
0.2
NFRC
Bug Screen
210120 - 20
Window
W - 409
Right
270
8
10
3
252
0.29
NFRC
0.2
NFRC
Bug Screen
9080 -18
Window
N - 122
Front
0
9
8
1
72
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 27 2
Window
N - 122
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
5056 - 5
Window
N - 122
Front
0
5
5.6
0
27.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 6
Window
E - 65
Left
90
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 16
Window
S - 173
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 1
Window
N - 253
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 2
Window
N - 253
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
6080 - 3
Window
W - 204
Right
270
6
8
1
48
0.29
NFRC
0.2
NFRC
Bug Screen
3080 - 4
Window
W - 204
Right
270
3
1 8
1
24
0.29
NFRC
0.2
NFRC
Bug Screen
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 8 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
2056 - 21
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2056 - 22
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 23
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 24
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 25
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 26
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 27
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2050 - 28
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 29
2
0.1
2
2
0
0
0
0
0
0
0
0
0
9080 - 30
2
0.1
2
2
0
0
0
0
0
0
0
0
0
12080 - 31
12
0.1
12
12
0
0
0
0
0
0
0
0
0
1061200 - 10
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3080 - 7
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 15
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 14
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 13
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 11
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 9 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
1630 - 12
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 17
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 18
2
0.1
2
2
0
0
0
0
0
0
0
0
0
80100 - 19
2
0.1
2
2
0
0
0
0
0
0
0
0
0
210120-20
18
0.1
18
18
0
0
0
0
0
0
0
0
0
9080 -18
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630-272
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5056 - 5
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630-6
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 16
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 1
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630-2
2
0.1
2
2
0
0
0
0
0
0
0
0
0
6080 - 3
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3080 - 4
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 10 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value and Depth
Carpeted Fraction
Heated
16552
Z1- 1655
1655
0.1
None
80%
No
15232
Z2 - 1523
1523
0.1
None
80%
No
4792
Z3 - 479
479
0.1
None
80%
No
264
Z4 - 527
264
0.1
None
80%
No
263
Z4 - 527
263
0.1
None
80%
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Inside Finish: Gypsum Board
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
R-0 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. 0. C.
R-0
None / None
0.277
Cavity / Frame: no insul. / 2x4
Other Side Finish: Gypsum Board
Inside Finish: Gypsum Board
R-21 Wall1
Interior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.064
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofZ1- 1655
Attic Roofs
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 11 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofZ2 - 1523
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofZ3 - 479
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Wood Framed
t r�
im
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Attic RoofZ4 - 527
Attic Roofs
Ceiling
2x4 @ 24 in. 0.
-
None / None
0.055
Siding/sheathing/decking
a s i
�
!
s
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Ceilings (below
Wood Framed
Over Ceiling Joists: R-28.9 insul.
R-38 + R-21 -
attic)
Ceiling
2x4 @ 24 in. 0. C.
R-38
None / None
0.025
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 12 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
Name
System Type
Distribution Type
Water Heater Name (#)
Solar Fraction (%)
Compact Distribution
HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System
DHW Heater 1 (2)
0
None
n/a
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Tank
Heating
#
Tank
Energy
Input Rating
Insulation
Standby Loss
1st Hr. Rating
NEEA Heat Pump
Tank Location or
Name
Element
Tank Type
Vol.
Factor or
or Recovery
Brand or Model /
Type
Units
(gal)
Efficiency
or Pilot
R-value
Eff.
or Flow Rate
Other
Ambient Condition
(Int/Ext)
DHW Heater 1
Natural Gas
Consumer
2
0
0.92-UEF
200000-
0
n/a
n/a
n/a
n/a
Instantaneous
Btu/Hr
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Type Compact Distribution
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/2
Not Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Name
System Type
Heating Unit
Cooling Unit
Fan Name
Distribution Name
Required
Heating
Cooling
Name
Name
Thermostat Type
Equipment Count
Equipment Count
AC-1 -1
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 1
Air Distribution
Setback
1
1
heating cooling
1
1
System 1
AC-2 -2
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 2
Air Distribution
Setback
1
1
heating cooling
2
2
System 2
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 13 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Name
System Type
Heating Unit
Cooling Unit
Fan Name
Distribution Name
Required
Heating
Cooling
Name
Name
Thermostat Type
Equipment Count
Equipment Count
AC-3 -3
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 3
Air Distribution
Setback
1
1
heating cooling
3
3
System 3
AC-4 -4
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 4
Air Distribution
Setback
1
1
heating cooling
4
4
System 4
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Heating
Cooling
Zonally
Compressor
Name
System Type
Number of Units
Controlled
Type
HERS Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
1-hers-htpump
Heat Pump System 2
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
2-hers-htpump
Heat Pump System 3
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
3-hers-htpump
Heat Pump System 4
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
4-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
355
Required
Required
Yes
Yes
Yes
Yes
1-hers-htpump
Heat Pump System
Required
355
Required
Required
Yes
Yes
Yes
Yes
2-hers-htpump
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 14 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
355
Required
Required
Yes
Yes
Yes
Yes
3-hers-htpump
Heat Pump System
Required
355
Required
Required
Yes
Yes
Yes
Yes
4-hers-htpump
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
1 05
06
07
08
1 09
10
11
12
Duct Ins.
Duct Location
Surface Area
R-value
Name
Type
Design Type
Supply
Return
supply
Return
Supply
Return
Bypass
Duct Leaka a
HERS Verification
Duct
Air Distribution
No
Sealed and
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 1
Tested
1-hers-dist
Duct
Air Distribution
No
Sealed and
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 2
Tested
2-hers-dist
Duct
Air Distribution
No
Sealed and
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 3
Tested
3-hers-dist
Duct
Air Distribution
No
Sealed and
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 4
Tested
4-hers-dist
Duct
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 15 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
target (%)
Location
Design
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
5
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 1-hers-dirt
Air Distribution
Yes
5
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 2-hers-dirt
Air Distribution
Yes
5
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 3-hers-dirt
Air Distribution
Yes
5
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 4-hers-dist
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 1
HVAC Fan
0.5
HVAC Fan 1-hers-fan
HVAC Fan 2
HVAC Fan
0.5
HVAC Fan 2-hers-fan
HVAC Fan 3
HVAC Fan
0.5
HVAC Fan 3-hers-fan
HVAC Fan 4
HVAC Fan
0.5
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.5
HVAC Fan 2-hers-fan
Required
0.5
Registration Number:
220-P010012257B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 11:59:55
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 16 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 3-hers-fan
Required
0.5
HVAC Fan 4-hers-fan
Required
0.5
IAQ (INDOOR AIR QUALITY) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery Effectiveness (%)
HERS Verification
SFam IAQVentRpt
155
0.25
Default
0
Yes
� CaICERTS, InL.
Registration Number:
220-P010012257B-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2019 Residential Compliance
Registration Date/Time:
2020-03-19 11:59:55
Report Version: 2019.1.100
Schema Version: rev 20190401
HERS Provider:
CaICERTS inc.
Report Generated: 2020-03-19 11:46:58
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 24 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 17 of 17)
Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
ARMANDO CHAVEZ
-�
Company:
Signature Date:
TITLE 24 OF THE DESERT
2020-03-19 11:59:30
Address:
CEA/ HERS Certification Identification (If applicable):
74800 shirley #62
N.A.
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760-278-1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Ruben Romero
Responsible Designer Signature: �
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC
2020-03-19 11:59:55
Address:
License:
74491 JONI DR SUITE #9
N.A.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-340-3528
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: Registration Date/Time:
220-P010012257B-000-000-0000000-0000 2020-03-19 11:59:55
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100
Schema Version: rev 20190401
HERS Provider:
Easy to Verify
at CaICERTS.com
CaICERTS inc.
Report Generated: 2020-03-19 11:46:58
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
PLAN # 24
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
311912020
Project Address
59000 MADISON ANDALUSIA C.C. LA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,184
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Attic
R 38 4,184 Add=R-21.0 New
Slab Unheated Slab -on -Grade
-
no insulation 4,184 Perim = 0' New
Wall Wood Framed
R 21 2,846 New
Demising Wood Framed
-
no insulation 220 New
FENESTRATION
Orientation Area(ft2)
Total Area: 995 Glazing Percentage: 23.8% New/Altered Average U-Factor: 0.29
U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 319.5
0.290
0.20 2.0 none N/A New
Rear (S) 170.5
0.290
0.20 2.0 none N/A New
Right (W) 96.0
0.290
0.20 12.0 none N/A New
Right (W) 152.0
0.290
0.20 2.0 none N/A New
Right (W) 252.0
0.290
0.20 18.0 none N/A New
Left (E) 4.5
0.290
0.20 2.0 none N/A New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
1 Split Heat Pump
9.50 HSPF
Split Heat Pump 16.0 SEER Setback
New
1 Split Heat Pump
9.50 HSPF
Split Heat Pump 16.0 SEER Setback
New
1 Split Heat Pump
9.50 HSPF
Split Heat Pump 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
AC-1 - Ducted
Ducted Attic 8.0
New
AC-2 - Ducted
Ducted Attic 8.0
New
AC-3 - Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
2 Small Instantaneous Gas
0
0.92 Standard New
EnegyP,, 8.0 by EnergySoft User Number. 20648
ID: 20 - GLS /001 - 002 -
Page 20 of 25
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
PLAN # 24
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
311912020
Project Address
59000 MADISON ANDALUSIA C.C. LA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,184
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
FENESTRATION Total Area: 995 Glazing Percentage: 23.8% New/Altered Average U-Factor: 0.29
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Split Heat Pump 9.50 HSPF
Split Heat Pump 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
AC-4 - Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EegyP,, 8.0 by EnerqySoft User Number. 20648
ID: 20 - GLS /001 - 002 -
Page 21 of 25
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 24
Date
3/19/2020
System Name
AC-1 -
Floor Area
1,655
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 922
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
18,162
562
305
12,213
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
23.6
1,048
467
Cooling System
0
0
Output per System
48,000
0
0
0
0
Total Output (Btuh)
48,000
1,489
562
-1,489
Total Output (Tons)
4.0
1,048
467
Total Output Btuh/sgft
29.0
Total Output s ft/Ton
413.8
1 21,747
11,658
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
4 TON 16/13/9.5
40,466
0
24,358
Airflow cfm/sgft
0.97
Airflow cfm/Ton
400.0
Outside Air ova
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
40,466
0
24,358
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
0 cfm
68 OF
68 OF 105 OF 106 OF
-Il I I I
Heating Coil Supply Fan
1,600 cfm
106 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76 / 62 IF
76/62OF 55/54OF 56/54OF
Cooling Coil Supply Fan 56 / 54 OF
1,600 cfm
46.4% ROOM
75 / 61 OF
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 24
Date
3/19/2020
System Name
AC-2 -
Floor Area
1,523
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 991
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
22,472
517
297
13,425
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
25.6
1,297
513
Cooling System
0
0
Output per System
60,000
0
0
0
0
Total Output (Btuh)
60,000
1,489
517
-1,489
Total Output (Tons)
5.0
1,297
513
Total Output Btuh/sgft
39.4
Total Output s ft/Ton
304.6
1 26,555
12,963
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
5 TON 16/13/9.5
49,456
0
24,358
Airflow cfm/sgft
1.31
Airflow cfm/Ton
400.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
49,456
0
24,358
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air -4 r-
0 cfm
68 OF
68 OF 110 OF 111 OF
fir
E
Heating Coil Supply Fan
2,000 cfm
110 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76/60°F
76/60°F 52/51 OF 53/51 OF
Cooling Coil Supply Fan 54 / 52 OF
2,000 cfm
41.6% ROOM
75/60°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 24
Date
3/19/2020
System Name
AC-3 -
Floor Area
479
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 258
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
5,671
163
115
3,673
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
81.4
327
140
Cooling System
0
0
Output per System
24,000
0
0
0
0
Total Output (Btuh)
24,000
1,489
163
-1,489
Total Output (Tons)
2.0
327
140
Total Output Btuh/sgft
50.1
Total Output s ft/Ton
239.5
1 7,815
2,465
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
2TON 16/13/9.5
19,730
0
24,358
Airflow cfm/sgft
1.67
Airflow cfm/Ton
400.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
19,730
0
24,358
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
0 cfm
68 OF
68 OF 96 OF ^ 98 OF
I - a110 r - -
Heating Coil Supply Fan
800 cfm
98 OF
IROIOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
75/60°F
75/60°F 52/51 OF 54/52°F
Cooling Coil Supply Fan 54 / 52 OF
800 cfm
41.3% ROOM
75/60°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 24
Date
3/19/2020
System Name
AC-4 -
Floor Area
527
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 349
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
7,586
179
119
3,816
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
74.0
438
146
Cooling System
0
0
Output per System
24,000
0
0
0
0
Total Output (Btuh)
24,000
1,489
179
-1,489
Total Output (Tons)
2.0
438
146
Total Output Btuh/sgft
45.5
Total Output s ft/Ton
263.5
1 9,951
2,619
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
2TON 16/13/9.5
19,759
0
24,358
Airflow cfm/sgft
1.52
Airflow cfm/Ton
400.0
Outside Air ova
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
19,759
0
24,358
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
0 cfm
68 OF
68 OF 96 OF ^ 98 OF
I - a110 r - -
Heating Coil Supply Fan
800 cfm
98 OF
IROIOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76 / 60 IF
76/60OF 52/51 OF 54/52OF
Cooling Coil Supply Fan 55 / 52 OF
800 cfm
41.5% ROOM Iff
75 / 60 OF
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
PLAN # 25
59000 MADISON ANDALUSIA C.C.
LA QUINTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528
Report Prepared by:
TITLE 24 OF THE DESERT SERVICES INC.
title24ofthedesert@gmail.com
760 278.1840,
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
04/23/2020 r)�D C
Job Number:
20 - GLS /001 - 005 - 2R
Date:
3/19/2020
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 21
Form MF-1 R Mandatory Measures Summary 23
HVAC System Heating and Cooling Loads Summary 27
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 1 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
GENERAL INFORMATION
01
Project Name
PLAN 25 ANDALUSIA
02
Run Title
Title 24 Analysis
03
Project Location
59000 MADISON ANDALUSIA C.C.
04
City
LA QUINTA
05
Standards Version
2019
06
Zip code
92253
07
Software Version
EnergyPro 8.0
08
Climate Zone
15
09
Front Orientation (deg/ Cardinal)
AIIOrientations
10
Building Type
SingleFamily
11
Number of Dwelling Units
1
12
Project Scope
NewConstruction
13
Number of Bedrooms
3
14
New Cond. Floor Area (ft)
0
15
Number of Stories
1
16
Existing Cond. Floor Area (ft)
n/a
17
Fenestration Average U-factor
0.29
18
Total Cond. Floor Area (ftZ)
4502
19
Glazing Percentage (%)
29.57%
20
ADU Bedroom Count
0
21
ADU Conditioned Floor Area
0
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 2 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency' (EDR)
TotalZ (EDR)
Efficiency' (EDR)
TotalZ (EDR)
Standard Design
45
23.3
Proposed Designs
North Facing
45
23.2
0
0.1
East Facing
42.2
20.5
2.8
2.8
South Facing
43
21.2
2
2.1
West Facing
41.8
20.1
3.2
3.2
RESULT: 3: COMPLIES ►
Efficiency EDR includes improvements to the building envelope and more efficient equipment
Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc.
s Building complies when efficiency and total compliance margins are greater than or equal to zero
• Standard Design PV Capacity: 8.13 kWdc
• Proposed PV Capacity Scaling: North (8.13 kWdc) East (8.13 kWdc) South (8.13 kWdc) West (8.13 kWdc)
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 3 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
ENERGY USE SUMMARY
Energy Use (kTDWft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.94
6.21
-1.27
-25.7
Space Cooling
98.79
96.48
2.31
2.3
IAQ Ventilation
1.67
1.67
0
0
Water Heating
4.45
5.43
-0.98
-22
Self Utilization Credit
n/a
0
0
n/a
North Facing Compliance Total
109.85
109.79
0.06
0.1
Space Heating
4.94
6.78
-1.84
-37.2
Space Cooling
98.79
87.71
11.08
11.2
IAQ Ventilation
1.67
1.67
0
0
Water Heating
4.45
5.43
-0.98
-22
Self Utilization Credit
n/a
=111111110M 0
0
n/a
East Facing Compliance Total
109.85
101.59
8.26
7.5
Space Heating
4.94
6.31
-1.37
-27.7
Space Cooling
98.79 S R k-1 90.53
8.26
8.4
IAQ Ventilation
1.67
1.67
0
0
Water Heating
4.45
5.43
-0.98
-22
Self Utilization Credit
n/a
0
0
n/a
South Facing Compliance Total
109.85
103.94
5.91
5.4
Space Heating
4.94
5.8
-0.86
-17.4
Space Cooling
98.79
87.56
11.23
11.4
IAQ Ventilation
1.67
1.67
0
0
Water Heating
4.45
5.43
-0.98
-22
Self Utilization Credit
n/a
0
0
n/a
West Facing Compliance Total
109.85
100.46
9.39
8.5
REQUIRED PV SYSTEMS
01 02 03 04 05 06 1 07 1 08 09 10 11
Registration Number: Registration Date/Time: HERS Provider:
220-P010012440B-000-000-0000000-0000 2020-03-19 15:20:02 CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 4 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
DC System Size
Exception
Module Type
Array Type
Power Electronics
CFI
Azimuth
Tilt
Array Angle
Tilt: (x in 12)
Inverter Eff.
(kWdc)
(deg)
Input
(deg)
N
8.13
NA
Standard
Fixed (roof
none
true
n/a
n/a
n/a
n/a
96
mount)
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• PV System: 8.13 kWdc
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• Quality insulation installation (QII)
• Indoor air quality ventilation
• Kitchen range hood i InL.
Cooling System Verifications: CaICERTS,
• Minimum Airflow
• Verified EER Ilk H E R S P R O V I D E R
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
Heating System Verifications:
• Verified HSPF
• Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
• Duct leakage testing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• -- None --
Registration Number: Registration Date/Time: HERS Provider:
220-P010012440B-000-000-0000000-0000 2020-03-19 15:20:02 CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 5 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftz)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
PLAN 25 ANDALUSIA
4502
1
3
4
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ftz)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
Z1- 897
Conditioned
AC-1 -1
897
10
DHW Sys 1
N/A
Z2 - 1187
Conditioned
AC-2 -2
1187
10
DHW Sys 1
N/A
Z3 - 1856
Conditioned
AC-3 -3
1856
10
DHW Sys 1
N/A
Z4 - 562
Conditioned
AC-4 -4
562
10
DHW Sys 1
N/A
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
N - 242
Z1- 897
R-21 Wall
0
Front
242
13.5
90
E - 150
Z1- 897
R-21 Wall
90
Left
228
22
90
S - 270
Z1- 897
R-21 Wall
180
Back
270
49.5
90
W - 150
Z1- 897
R-21 Wall
270
Right
256.1
256
90
N - 140
Z2 - 1187
R-21 Wall
0
Front
140
35.2687
90
S - 562
Z2 - 1187
R-21 Wall
180
Back
562
77.739
90
W - 165
Z2 - 1187
R-21 Wall
270
Right
165
96
90
N - 580
Z3 - 1856
R-21 Wall
0
Front
580
107.5
90
E - 440
Z3 - 1856
R-21 Wall
90
Left
440
228
90
S - 130
Z3 - 1856
R-21 Wall
180
Back
130
0
90
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 6 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
W - 495
Z3 - 1856
R-21 Wall
270
Right
495
288.015
90
N - 292
Z4 - 562
R-21 Wall
0
Front
292
60.5055
90
E- 205
Z4 - 562
R-21 Wall
90
Left
205
25.14
90
S- 292
Z4-562
R-21 Wall
180
Back
292
24
90
W -205
Z4-562
R-21 Wall
270
Right
205
48
90
897
Z1- 897
R-38 + R-21
n/a
n/a
897
n/a
n/a
1187
Z2 - 1187
R-38 + R-21
n/a
n/a
1187
n/a
n/a
1856
Z3 - 1856
R-38 + R-21
n/a
n/a
1856
n/a
n/a
562
Z4 - 562
R-38 + R-21
n/a
n/a
562
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Z1- 897
Attic RoofZ1- 897
Ventilated
4
0.1
0.85
No
No
Attic Z2 - 1187
Attic RoofZ2 - 1187
Ventilated
4
0.1
0.85
No
No
Attic Z3 - 1856
Attic RoofZ3 - 1856
Ventilated
4
0.1
0.85
No
No
Attic Z4 - 562
Attic RoofZ4 - 562
Ventilated
4
0.1
0.85
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MuIt.
Area
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
e
Exterior
Shading
1630 - 30
Window
N - 242
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 31
Window
N - 242
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 31 2
Window
N - 242
Front
0
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
4056 - 33
Window
E - 150
Left
90
4
5.5
1
22
0.29
NFRC
0.2
NFRC
Bug Screen
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 7 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MuIt.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
a
Exterior
Shading
2056 - 34
Window
S - 270
Back
180
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
2056 - 35
Window
S - 270
Back
180
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
5056 - 36
Window
S - 270
Back
180
5
5.5
1
27.5
0.29
NFRC
0.2
NFRC
Bug Screen
(3) 2880 - 11
Window
W - 150
Right
270
8
8
1
64
0.29
NFRC
0.2
NFRC
Bug Screen
160120 - 10
Window
W - 150
Right
270
16
12
1
192
0.29
NFRC
0.2
NFRC
Bug Screen
2656 - 9
Window
N - 140
Front
0
2.5
5.5
0
11.76
0.29
NFRC
0.2
NFRC
Bug Screen
2656 - 10
Window
N - 140
Front
0
2.5
5.5
0
11.76
0.29
NFRC
0.2
NFRC
Bug Screen
2656 - 11
Window
N - 140
Front
0
2.5
5.5
0
11.76
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 17
Window
S - 562
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
2656 - 16
Window
S - 562
Back
180
2.5
5.5
1
13.75
0.29
NFRC
0.2
NFRC
Bug Screen
2656 - 15
Window
S - 562
Back
180
2.5
5.5
1
13.75
0.29
NFRC
0.2
NFRC
Bug Screen
2656 - 14
Window
S - 562
Back
180
2.5
5.5
1
13.75
0.29
NFRC
0.2
NFRC
Bug Screen
1630 - 13
Window
S - 562
Back
180
1.5
3
1
4.5
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 19
Window
S - 562
Back
180
3
5.5
0
13.74
0.29
NFRC
0.2
NFRC
Bug Screen
3056 - 18
Window
S - 562
Back
180
3
5.5
0
13.74
0.29
NFRC
0.2
NFRC
Bug Screen
12080 - 28
Window
W - 165
Right
270
12
8
1
96
0.29
NFRC
0.2
NFRC
Bug Screen
9080 - 23
Window
N - 580
Front
0
9
8
1
72
0.29
NFRC
0.2
NFRC
Bug Screen
2020 - 20
Window
N - 580
Front
0
2
2
1
4
0.29
NFRC
0.2
NFRC
Bug Screen
2020 - 21
Window
N - 580
Front
0
2
2
1
4
0.29
NFRC
0.2
NFRC
Bug Screen
5056 - 22
Window
N - 580
Front
0
5
5.5
1
27.5
0.29
NFRC
0.2
NFRC
Bug Screen
90120 - 24
Window
E - 440
Left
90
9
12
1
108
0.29
NFRC
0.2
NFRC
Bug Screen
3080 RND TOP - 25
Window
E - 440
Left
90
3
10
1
48
0.29
NFRC
0.2
NFRC
Bug Screen
9080 - 12
Window
E - 440
Left
90
9
8
1
72
0.29
NFRC
0.2
NFRC
Bug Screen
10080 - 27
Window
W - 495
Right
270
10
8
1
80
0.29
NFRC
0.2
NFRC
Bug Screen
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 8 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MuIt.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
a
Exterior
Shading
174120 - 29
Window
W - 495
Right
270
17.3
12
1
208.0
0.29
NFRC
0.2
NFRC
Bug Screen
5056 - 33
Window
N - 292
Front
0
3
5.5
1
27.51
0.29
NFRC
0.2
NFRC
Bug Screen
2056 - 1
Window
N - 292
Front
0
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
2056 - 2
Window
N - 292
Front
0
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
2056 - 3
Window
N - 292
Front
0
2
5.5
1
11
0.29
NFRC
0.2
NFRC
Bug Screen
4056 - 5
Window
E- 205
Left
90
4
5.5
1
22
0.29
NFRC
0.2
NFRC
Bug Screen
24 RND FG - 6
Window
E- 205
Left
90
1
2.5
1
3.14
0.29
NFRC
0.2
NFRC
Bug Screen
3080 - 24
Window
S- 292
Back
180
3
8
1
24
0.29
NFRC
0.2
NFRC
Bug Screen
6080 - 7
Window
W - 205
Right
270
6
8
1
48
0.29
NFRC
0.2
NFRC
Bug Screen
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
1630 - 30
8
0.1
8
8
0
0
0
0
0
0
0
0
0
1630-31
8
0.1
8
8
0
0
0
0
0
0
0
0
0
1630-312
8
0.1
8
8
0
0
0
0
0
0
0
0
0
4056 - 33
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2056 - 34
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2056 - 35
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5056 - 36
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 9 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
(3) 2880 - 11
2
0.1
2
2
0
0
0
0
0
0
0
0
0
160120 - 10
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656 - 9
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656 - 10
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656 - 11
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 17
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656 - 16
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656 - 15
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656 - 14
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1630 - 13
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 19
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3056 - 18
2
0.1
2
2
0
0
0
0
0
0
0
0
0
12080 - 28
12
0.1
12
12
0
0
0
0
0
0
0
0
0
9080 - 23
30
0.1
30
30
0
0
0
0
0
0
0
0
0
2020 - 20
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2020 - 21
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5056 - 22
18
0.1
18
18
0
0
0
0
0
0
0
0
0
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 10 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
90120 - 24
12
0.1
12
12
0
0
0
0
0
0
0
0
0
3080 RND TOP - 25
2
0.1
2
2
0
0
0
0
0
0
0
0
0
9080 - 12
10
0.1
10
10
0
0
0
0
0
0
0
0
0
10080 - 27
2
0.1
2
2
0
0
0
0
0
0
0
0
0
174120 - 29
18
0.1
18
18
0
0
0
0
0
0
0
0
0
5056 - 33
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2056 - 1
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2056 - 2
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2056 - 3
2
0.1
2
2
0
0
0
0
0
0
0
0
0
4056 - 5
2
0.1
2
2
0
0
0
0
0
0
0
0
0
24RNDFG-6
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3080 - 24
8
0.1
8
8
0
0
0
0
0
0
0
0
0
6080 - 7
2
0.1
2
2
0
0
0
0
0
0
0
0
0
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value and Depth
Carpeted Fraction
Heated
8972
Z1- 897
897
0.1
None
80%
No
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 11 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value and Depth
Carpeted Fraction
Heated
11872
Z2 - 1187
1187
0.1
None
80%
No
18562
Z3 - 1856
1856
0.1
None
80%
No
562 2
Z4 - 562
562
0.1
None
80%
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Inside Finish: Gypsum Board
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
R-0 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. 0. C.
R-0
None / None
0.277
Cavity / Frame: no insul. / 2x4
Other Side Finish: Gypsum Board
Inside Finish: Gypsum Board
R-21 Wall1
Interior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.064
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Attic RoofZ1- 897
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Attic RoofZ2 - 1187
Attic Roofs
Wood Framed
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 20
Around Roof Joists: R-8.0 insul.
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 12 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofZ3 - 1856
Attic Roofs
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofZ4 - 562
Attic Roofs
2x4 @ 24 in. 0. C.
R-21
None / None
0.055
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-8.0 insul.
Ceilings (below
Wood Framed
Over Ceiling Joists: R-28.9 insul.
R-38 + R-21 --
attic)
Ceiling
2x4 @ 24 in. 0. C.
R-38
None / None
0.025
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
Name
System Type
Distribution Type
Water Heater Name (#)
Solar Fraction (%)
Compact Distribution
HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System
DHW Heater 1 (2)
0
None
n/a
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 13 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Tank
Heating
#
Tank
Energy
Input Rating
Insulation
Standby Loss
1st Hr. Rating
NEEA Heat Pump
Tank Location or
Name
Element
Tank Type
Vol.
Factor or
or Recovery
Brand or Model /
Type
Units
(gal)
Efficiency
or Pilot
R-value
Eff.
or Flow Rate
Other
Ambient Condition
(Int/Ext)
DHW Heater 1
Natural Gas
Consumer
2
0
0.92-UEF
200000
0
n/a
n/a
n/a
n/a
Instantaneous
Btu/Hr
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Type Compact Distribution
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/2
Not Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating Unit
Cooling Unit
Required
Heating
Cooling
Name
System Type
Name
Name
Fan Name
Distribution Name
Thermostat Type
Equipment Count
Equipment Count
AC-1 -1
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 1
Air Distribution
Setback
1
1
heating cooling
1
1
System 1
AC-2 -2
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 2
Air Distribution
Setback
1
1
heating cooling
2
2
System 2
AC-3 -3
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 3
Air Distribution
Setback
1
1
heating cooling
3
3
System 3
AC-4 -4
Heat pump
Heat Pump System
Heat Pump System
HVAC Fan 4
Air Distribution
Setback
1
1
heating cooling
4
4
System 4
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 14 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Heating
Cooling
Zonally
Compressor
Name
System Type
Number of Units
Controlled
Type
HERS Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
Central split HP
1
9.5
60000
45000
16
13
Not Zonal
Single
Heat Pump System
Speed
1-hers-htpump
Heat Pump System 2
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
2-hers-htpump
Heat Pump System 3
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
3-hers-htpump
Heat Pump System 4
Central split HP
1
9.5
39000
35500
16
13
Not Zonal
Single
Heat Pump System
Speed
4-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
360
Required
Required
Yes
Yes
Yes
Yes
1-hers-htpump
Heat Pump System
Required
360
Required
Required
Yes
Yes
Yes
Yes
2-hers-htpump
Heat Pump System
Required
360
Required
Required
Yes
Yes
Yes
Yes
3-hers-htpump
Heat Pump System
Required
360
Required
Required
Yes
Yes
Yes
Yes
4-hers-htpump
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 15 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
1 05
06
07
08
1 09
10
11
12
Duct Ins.
Duct Location
Surface Area
R-value
Name
Type
Design Type
Supply
Return
Supply
Return
SuPPIY
Return
Bypass
Duct Leaka a
HERS Verification
Duct
Air Distribution
No
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 1
1-hers-dist
Duct
Air Distribution
No
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 2
2-hers-dist
Duct
Air Distribution
No
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 3
3-hers-dist
Duct
Air Distribution
No
Air Distribution System
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 4
4-hers-dist
Duct
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
target (%)
Location
Design
g
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
3
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 1-hers-dirt
Air Distribution
Yes
3
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 2-hers-dist
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 16 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
target (%)
Location
Design
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
3
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 3-hers-dirt
Air Distribution
Yes
3
Not Required
Not Required
Not Required
Credit not taken
Required
No
System 4-hers-dirt
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 1
HVAC Fan
0.5
HVAC Fan 1-hers-fan
HVAC Fan 2
HVAC Fan
0.5
HVAC Fan 2-hers-fan
HVAC Fan 3
HVAC Fan
0.5
HVAC Fan 3-hers-fan
HVAC Fan 4
HVAC Fan
0.5
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.5
HVAC Fan 2-hers-fan
Required
0.5
HVAC Fan 3-hers-fan
Required
0.5
HVAC Fan 4-hers-fan
Required
0.5
Registration Number:
220-P010012440B-000-000-0000000-0000
Registration Date/Time:
2020-03-19 15:20:02
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58
Schema Version: rev 20190401
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 17 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
IAQ (INDOOR AIR QUALITY) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery Effectiveness (%)
HERS Verification
SFam IAQVentRpt 1-1
110
0.0727273
Default
0
Yes
SFam IAQVentRpt 2-1
110
0.0727273
Default
0
Yes
SFam IAQVentRpt 3-1
110
0.0727273
Default
0
Yes
SFam IAQVentRpt 4-1
110
0.0727273
Default
0
Yes
� CaICERTS, Inc.
Registration Number:
220-P010012440B-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2019 Residential Compliance
Registration Date/Time:
2020-03-19 15:20:02
Report Version: 2019.1.100
Schema Version: rev 20190401
HERS Provider:
CaICERTS inc.
Report Generated: 2020-03-19 15:07:58
CERTIFICATE OF COMPLIANCE
Project Name: PLAN 25 ANDALUSIA
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 18 of 18)
Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
ARMANDO CHAVEZ
-�
Company:
Signature Date:
TITLE 24 OF THE DESERT
2020-03-19 15:19:21
Address:
CEA/ HERS Certification Identification (If applicable):
74800 shirley #62
N.A.
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760-278-1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Ruben Romero
Responsible Designer Signature: �
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC
2020-03-19 15:20:02
Address:
License:
74491 JONI DR SUITE #9
N.A.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-340-3528
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: Registration Date/Time:
220-P010012440B-000-000-0000000-0000 2020-03-19 15:20:02
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100
Schema Version: rev 20190401
HERS Provider:
J, �_
Easy to Verify
at CaICERTS.com
CaICERTS inc.
Report Generated: 2020-03-19 15:07:58
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
PLAN # 25
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
311912020
Project Address
59000 MADISON ANDALUSIA C.C. LA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,502
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft)
Special Features Status
Roof Wood Framed Attic
R 38 4,502
Add=R-21.0
New
Slab Unheated Slab -on -Grade
-
no insulation 4,502
Perim = 0'
New
Wall Wood Framed
R 21 3,685
New
Demising Wood Framed
-
no insulation 220
New
FENESTRATION
Orientation Area(ft2)
Total Area: 1,331 Glazing Percentage: 29.6%
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor: 0.29
Exterior Shades Status
Front (N) 13.5
0.290
0.20 8.0
none
N/A New
Left (E) 95.1
0.290
0.20 2.0
none
N/A New
Rear (S) 127.3
0.290
0.20 2.0
none
N/A New
Right (W) 384.0
0.290
0.20 2.0
none
N/A New
Front (N) 103.8
0.290
0.20 2.0
none
N/A New
Right (W) 96.0
0.290
0.20 12.0
none
N/A New
Front (N) 72.0
0.290
0.20 30.0
none
N/A New
Front (N) 27.5
0.290
0.20 18.0
none
N/A New
Left (E) 108.0
0.290
0.20 12.0
none
N/A New
Left (E) 72.0
0.290
0.20 10.0
none
N/A New
Right (W) 208.0
0.290
0.20 18.0
none
N/A New
Rear (S) 24.0
0.290
0.20 8.0
none
N/A New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Split Heat Pump
9.50 HSPF
Split Heat Pump
16.0 SEER
Setback
New
1 Split Heat Pump
9.50 HSPF
Split Heat Pump
16.0 SEER
Setback
New
1 Split Heat Pump
9.50 HSPF
Split Heat Pump
16.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R-Value Status
AC-1 - Ducted
Ducted Attic
8.0
New
AC-2 - Ducted
Ducted Attic
8.0
New
AC-3 - Ducted
Ducted Attic
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff
Distribution Status
2 Small Instantaneous Gas
0
0.92
Standard
New
EnegyP,, 8.0 by EnergySoft User Number. 20648
ID: 20 - GLS /001 - 005 -
Page 21 of 30
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
PLAN # 25
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
311912020
Project Address
59000 MADISON ANDALUSIA C.C. LA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,502
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
FENESTRATION Total Area: 1,331 Glazing Percentage: 29.6% New/Altered Average U-Factor: 0.29
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Split Heat Pump 9.50 HSPF
Split Heat Pump 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
AC-4 - Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EegyP,, 8.0 by EnerqySoft User Number. 20648
ID: 20 - GLS /001 - 005 -
Page 22 of 30
2019 Low -Rise Residential Mandatory Measures Summary
NOTE. -Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(Original 08/2019)
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm per square foot or less
when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 10l/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products and exterior doors must have a label meeting the requirements of Section 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables
110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather stripped.*
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods
and Services BHGS .
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of Section 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8 i and be labeled er 10-113 when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or
§ 150.0(c):
have a U-factor of 0.071 or less, (R-19 in 2x6 or U-factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-
factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly. Masonry walls must meet Table 150.1-A or B.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.`
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV
light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g).
Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor
§ 150.0(g)1:
retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.`
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 110.5(e)
Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces.
§ 150.0(e)l:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)2:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.`
§ 150.0(e)3:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.`
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
§ 110.2(c):
Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)4:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)4.
§ 110.3(c)6:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU per hour (2 kW) must have isolation valves with hose
bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook,
§ 150.0(h)l:
Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards
Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2.
0 2019 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water Piping, Solar Water -heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must
be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum
§ 150.00)2A:
insulation wall thickness of 1 inch or a minimum insulation R-value of 7.7: the first 5 feet of cold water pipes from the storage tank; all hot water
piping with a nominal diameter equal to or greater than 3/4 inch and less than 1 inch; all hot water piping with a nominal diameter less than 3/4
inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks, buried below
grade, and from the heating source to kitchen fixtures.*
§ 150.00)3:
Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes).
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a
Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non -crushable casing or sleeve.
Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of
§ 150.0(n)1:
the following: A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10
AWG copper branch circuit, within 3 feet from the water heater without obstruction. Both ends of the unused conductor must be labeled with the
word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker
for the branch circuit and labeled with the words "Future 240V Use"; a Category III or IV vent, or a Type B vent with straight pipe between the
outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of
the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing
agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with California Mechanical Code (CMC) Section 604.0. If a
contractor installs the insulation, the contractor must certify to the customer in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must meet the requirements of the CMC Section 601.0, 602.0, 603.0, 604.0,
605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air
ducts and plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in
conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed
§ 150.0(m)1:
and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must
be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of
UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than
% inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums
designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air.
Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause
reductions in the cross -sectional area:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed
§ 150.0(m)9:
to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular
foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or
§ 150.0(m)12:
equivalent filters. Filters for space conditioning systems must have a 2 inch depth or can be 1 inch if sized per Equation 150.0-A. Pressure drops
and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.*
Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole
for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be >_ 350 CFM
§ 150.0(m)13:
per ton of nominal cooling capacity, and an air -handling unit fan efficacy:5 0.45 watts per CFM for gas furnace air handlers and <_ 0.58 wafts per
CFM for all others. Small duct high velocity systems must provide an airflow >_ 250 CFM per ton of nominal cooling capacity, and an air -handling
unit fan efficacy < 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.*
0 2019 Low -Rise Residential Mandatory Measures Summary
Requirements for Ventilation and Indoor Air Quality:
Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation
§ 150.0(o)1:
and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1.
Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with
§ 150.0(o)1 C:
other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates
determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C.
Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in
§ 150.0(o)1 E:
accordance with Equation 150.0-13 and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced
system is not used, all units in the building must use the same system type and the dwelling -unit envelope leakage must be:5 0.3 CFM at 50 Pa
(0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8.
Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide
§ 150.0(o)1 F:
ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be
within 20% of the unit with the lowest airflow rate as it relates to the individual unit's minimum required airflow rate needed for compliance.
§ 150.0(o)1 G:
Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2.
§ 150.0(o)2:
Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential
Appendix RA3.7. Kitchen range hoods must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is
rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1:
Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or
dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9..
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C.
§ 150.0(k)1 D:
Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an
output frequency no less than 20 kHz.
Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be
§ 150.0(k)1 E:
controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0 k .'
§ 150.0(k)1G:
Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB.'
§ 150.0(k)1 H:
Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated
temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to
§ 150.0(k)1 I:
comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no
more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed.
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems!
§ 150.0(k)2C:
Interior Switches and Controls. Lighting must have readily accessible wall -mounted controls that allow the lighting to be manually
turned ON and OFF.*
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to
comply with § 150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
2019 Low -Rise Residential Mandatory Measures Summary
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it:
§ 150.0(k)2G:
provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the
EMCS requirements of § 130.0 e ; and meets all other requirements in § 150.0(k)2.
§ 150.0(k)2H:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by an occupant sensor or a vacancy sensor providing automatic -off functionality. If an occupant sensor is installed, it must be
initially configured to manual -on operation using the manual control required under Section 150.0(k)2C.
§ 150.0(k)2J:
Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for
dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.`
§ 150.0(k)2K:
Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling -installed lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either
150.0 k 3Aii(photocell and either a motion sensor or automatic time switch control or § 150.0 k 3Aiii astronomical time clock), or an EMCS.
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances,
§ 150.0(k)3B:
balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either Section
150.0 k 3A or with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots
or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by Section 150.0(k)3B or Section 150.0(k)3D must
comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be comply with Table 150.0-A and be controlled by an occupant sensor.
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in
§ 150.0(k)6B:
that building must:
i. Comply with the applicable requirements in Sections 110.9,130.0,130.1,140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which
do not have a photovoltaic system installed must comply with the requirements of § 110.1 0b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multifamily Buildings. Low-rise multi -family buildings that do not have a photovoltaic system installed must comply with the
requirements of § 110.10(b) through § 110.10(d).
Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access,
pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted
by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80
square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with
§ 110.10(b)1:
roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building
and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of
the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the
building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone
requirement is applicable to the entire building, including mixed occupancy.*
§ 110.10(b)2:
Azimuth. All sections of the solar zone located on steep -sloped roofs must be oriented between 90 degrees and 300 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a
§ 110.10(c):
pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family
residences and central water -heating systems, a pathway reserved for routing plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 25
Date
3/19/2020
System Name
AC-1 -
Floor Area
897
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 723
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
60,000
14,002
304
223
9,012
Total Output (Btuh)
60,000
0
Output (Btuh/sqft)
66.9
808
345
Cooling System
0
0
Output per System
36,000
0
0
0
0
Total Output (Btuh)
36,000
1,489
304
-1,489
Total Output (Tons)
3•0
808
345
Total Output Btuh/sgft
40.1
Total Output s ft/Ton
299.0
1 17,108
8,213
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
3 TON 16/13/9.5 - SEER/EER/HSPF
27,454
2,881
37,474
Airflow cfm/sgft
1.34
Airflow cfm/Ton
400.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
27,454
2,881
37,474
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air -4 r-
0 cfm
68 OF
68 OF 105 OF 106 OF
E -Il I I I
Heating Coil Supply Fan
1,200 cfm
106 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76 / 62 IF
76/62°F 55/54°F 56/54°F
Cooling Coil Supply Fan 57 / 55 OF
1,200 cfm--W
46.3% Fkoom
75 / 61 OF
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 25
Date
3/19/2020
System Name
AC-2 -
Floor Area
1,187
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 581
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
12,925
403
398
8,370
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
32•9
746
320
Cooling System
0
0
Output per System
36,000
0
0
0
0
Total Output (Btuh)
36,000
1,489
403
-1,489
Total Output (Tons)
3.0
746
320
Total Output (Btuh/sqft)
30.3
Total Output (sqf /Ton)
395.7
15,906
7,521
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,200
3 TON 16/13/9.5
29,677
0
24,358
Airflow (cfm/sgft)
1.01
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
29,677
0
24,358
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 IF
Outside Air -4 r-
cfm
68 OF
go
68 OF 88 OF
E0 v I I 1
Heating Coil Supply Fan
1,200 cfm
11
88 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76 / 60 IF
76/60OF 52/51 OF 54/52OF
0'
Cooling Coil Supply Fan 54 / 52 OF
1,200 cfm
41.7% ROOM
75 / 60 OF
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 25
Date
3/19/2020
System Name
AC-3 -
Floor Area
1,856
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,008
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
22,861
630
370
16,680
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
21.0
1,320
638
Cooling System
0
0
Output per System
60,000
0
0
0
0
Total Output (Btuh)
60,000
1,489
630
-1,489
Total Output (Tons)
5.0
1,320
638
Total Output Btuh/sgft
32.3
Total Output s ft/Ton
371.2
1 26,989
16,466
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
5 TON 16/13/9.5
49,475
0
24,358
Airflow cfm/sgft
1.08
Airflow cfm/Ton
400.0
Outside Air ova
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
49,475
0
24,358
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air -4 r-
0 cfm
68 OF
68 OF 110 OF 111 OF
fir
E
Heating Coil Supply Fan
2,000 cfm
110 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76/60°F
76/60°F 52/51 OF 53/51 OF
Cooling Coil Supply Fan 54 / 52 OF
2,000 cfm
41.7% ROOM
75/60°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
PLAN # 25
Date
3/19/2020
System Name
AC-4 -
Floor Area
562
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 356
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
39,000
7,743
191
195
6,201
Total Output (Btuh)
39,000
0
Output (Btuh/sqft)
69•4
447
237
Cooling System
0
0
Output per System
24,000
0
0
0
0
Total Output (Btuh)
24,000
1,489
191
-1,489
Total Output (Tons)
2.0
447
237
Total Output Btuh/sgft
42.7
Total Output s ft/Ton
281.0
1 10,126
5,186
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
2TON 16/13/9.5
19,763
0
24,358
Airflow cfm/sgft
1.42
Airflow cfm/Ton
400.0
Outside Air ova
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
19,763
0
24,358
Outside Air cfm/sgft
0.00
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
0 cfm
68 OF
68 OF 96 OF ^ 98 OF
I - a110 r - -
Heating Coil Supply Fan
800 cfm
98 OF
IROIOM
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air
0 cfm
76 / 60 IF
76/60OF 52/51 OF 54/52OF
Cooling Coil Supply Fan 55 / 52 OF
800 cfm
41.5% ROOM Iff
75 / 60 OF