Loading...
Andalusia TR 31681-3 BCPR2020-0001 (Plan 24 & 25) 2019 Code Update!� ylProject Details PROJECT NUMBER Cit of La Quinta BCPR2020-0001 Description: ANDALUSIA / 2019 CODE UPDATE / PLAN 24, 25 Status: APPROVED Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB) Status Date: 4/14/2020 Subtype: TRACT RESIDENTIAL Applied: 1/24/2020 Address: 59000 MADISON ST Approved: City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: Expired: Details: CODE UPDATE FOR 4184 SF DWELLING - PLAN 24 AND 4502 SF DWELLING - PLAN 25 [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2019 CALIFORNIA BUILDING CODES. DAYS REVIEWS ACTIONS INSPECTIONS CONDITIONS CASE OPEN OPEN COMPLETED A 1 9 • CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES COUNTER VISIT AARON HICKSON 1/27/2020 1/27/2020 LOWERED PLAN CHECK PER AJ NOTE AARON HICKSON 2/18/2020 2/18/2020 PLAN CHECK RECEIVED FROM INTERWEST REVISIONS REQUIRED EMAIL DUANE CLAYTON 3/4/2020 3/4/2020 - INFORMED APPLICANT THAT PLANS REQUIRE REVISIONS. - OBTAIN CORRECT INTERWEST COMMENT LIST FOR PLANS NOTE DUANE CLAYTON 3/4/2020 3/5/2020 24 AND 25. ATTACH IN TRAKIT AND INFORM APPLICANT THAT REVISIONS TO PLANS ARE REQUIRED. BY NOLAN SPARKS APPLICANT DID NOT PICK UP CITY CORRECTION LIST SINCE IT 1ST PC PICKED UP AARON HICKSON 3/5/2020 3/5/2020 WAS INCORRECT. DUANE WILL SEND APPLICANT CORRECT CORRECTION LIST BY EMAIL. WE WERE UNABLE TO VERIFY ITEMS THAT WERE SUPPOSE TO BE GIVEN BACK TO APPLICANT. Printed: Wednesday, December 20, 2023 10:27:52 AM 1 of 7 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0001 EMAIL DUANE CLAYTON 3/5/2020 3/5/2020 - SENT CITY AND CONSULTANT CORRECTION LISTS TO APPLICANT VIA EMAIL. EMAIL DUANE CLAYTON 3/5/2020 3/5/2020 - INFORMED APPLICANT THAT PLAN REVIEW IS COMPLETE AND REQUIRES REVISIONS. EMAIL DUANE CLAYTON 4/23/2020 4/23/2020 - INFORMED APPLICANT THAT PLANS ARE APPROVED. DEPOSIT OF $750 WHICH WAS NOT USED WILL BE REFUNDED NOTE ARMANDO MAGALLON 2/24/2021 2/24/2021 BACK TO APPLICANT. REFUND CANNOT BE REFUNDED BACK TO APPLICANT VIA CREDIT DUE TO HOW OLD IT IS. CHECK REQUEST WILL BE NEEDED. NOTE LORI LORETT 3/8/2021 3/8/2021 REFUND PROCESSED FOR $750.00, CHECK MAILED 3/5/2021. REFUND HAS BEEN COMPLETED - THE MONEY HAD NOT BEEN MOVED OVER FROM ACOUNT 42600 TO 42300 ON THE NOTE ARMANDO MAGALLON 3/10/2021 3/10/2021 FINANCIAL SIDE. THE REFUND WAS COMPLETED FROM ACCOUNT 42600 FOR THE FINANCIAL SIDE BUT FROM 42300 FROM THE TRAKIT SIDE. NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT NOLAN SPARKS / SUNRISE LQ, LLC 81570 CARBONERAS LA QUINTA CA 92253 NSPARKS@RANCHOLA QUINTA.COM CONTRACTOR NATIONAL MORTGAGE & LAND 300 EAGLE DANCE PALM DESERT CA 92211 COMPANY CIRCLE OWNER T D DESERT DEV 81570 CARBONERAS LA QUINTA CA 0 NCIAL INFORMFIN •� CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY NATIONAL HOURLY CHARGE - CITY 101-0000-42600 2 $322.00 $322.00 4/23/20 WEB4959 CREDIT MORTGAGE & LAND ECON BUILDING STAFF CO M PA Printed: Wednesday, December 20, 2023 10:27:52 AM 2 of 7 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0001 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY HOURLY CHARGE - NATIONAL INTERWEST PLANS 101-0000-42600 3 $300.00 $300.00 4/23/20 WEB4959 CREDIT MORTGAGE & LAND ECON EXAMINER COMPA HOURLY CHARGE - NATIONAL INTERWEST 101-0000-42600 4 $500.00 $500.00 4/23/20 WEB4959 CREDIT MORTGAGE & LAND ECON STRUCTURAL PLAN COMPA REVIEW Total Paid for BUILDING STAFF - PER HOUR: $1,122.00 $1,122.00 BUILDING TRACT RESIDENTIAL 101-0000-42600 1 $750.00 $750.00 1/24/20 MR829 867270 CREDIT NOLAN SPARKS AHI CONSTRUCTION PLAN CARD DEPOSIT Total Paid for BUILDING TRACT RESIDENTIAL $750.00 $750.00 CONSTRUCTION PLAN DEPOSIT: 101-0000-42600 ($750.00) ($750.00) 2/24/21 OFFSET OFFSET AMA CASH OVER 101-0000-42300 0 $750.00 $750.00 2/24/21 DEPOSIT DEPOSIT AMA Total Paid for CASH OVER: $0.00 $0.00 RECORDS NATIONAL MANAGEMENT FEE - 101-0000-42416 0 $21.00 $21.00 4/14/20 WEB4889 CREDIT MORTGAGE & LAND ECON MAJOR COMPA Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 REFUND / UNUSED 101-0000-42300 0 ($750.00) ($750.00) 3/7/21 R64171 204223 CHECK NOLAN SPARKS AMA DEPOSIT Total Paid for REFUND / UNUSED DEPOSIT: ($750.00) ($750.00) NATIONAL TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 4/14/20 WEB4889 CREDIT MORTGAGE & LAND ECON ENHANCEMENT FEE COMPA Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 Printed: Wednesday, December 20, 2023 10:27:52 AM 3 of 7 CENTRALSQUARE Project Details PROJECT NUMBER City of La Quinta BCPR2020-0001 • INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE 1ST BLDG INTERWEST 1/24/2020 2/14/2020 2/17/2020 REVISIONS REQUIRED PC1 plans to be delivered via GSO Tracking # COMPLETE (3WK) 547991435. 1ST BLDG NS (3WK) DUANE 1/24/2020 2/14/2020 3/4/2020 REVISIONS REQUIRED - SEE 1ST REVIEW NS AND STR CORRECTIONS IN CLAYTO N ATTACHMENTS. 1ST FIRE (2WK) KOHL 1/24/2020 2/7/2020 2/18/2020 NOT REQUIRED HETRICK 1ST PLANNING CARLOS 1/24/2020 2/7/2020 2/6/2020 READY FOR APPROVAL (2WK) FLORES 1ST PUBLIC WORKS AMY YU 1/24/2020 2/7/2020 2/6/2020 READY FOR APPROVAL FOOTPRINT NOT CHANGED PER NOLAN (2WK) 2ND BLDG INTERWEST 4/14/2020 4/28/2020 4/22/2020 APPROVED DIGITAL RESUBMITTAL. PLEASE SEE 2ND COMPLETE (2WK) SUBMITTAL DOCUMENTS IN ATTACHMENTS. 2ND BLDG NS (2WK) DUANE 4/14/2020 4/28/2020 4/23/2020 APPROVED - SEE APPROVED PLAN AND DOCUMENTS IN CLAYTO N ATTACHMENTS. 11 1w Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 59000 MADISON - 1ST 1ST REVIEW DOC 3/5/2020 DUANE CLAYTON CORRECTION LIST - CITY REVIEW CORRECTION 0 LIST - CITY OF LA- OF LA-QUINTA QUINTA.pdf Printed: Wednesday, December 20, 2023 10:27:52 AM 4 of 7 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0001 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 59000 MADISON APPROVED- (BCPR2020-0001) - DOC 4/23/2020 DUANE CLAYTON ARCHITECTURAL APPROVED- 1 DRAWINGS - PLANS 24 ARCHITECTURAL AND 25 DRAWINGS - PLANS 24 AND 25.pdf 59000 MADISON DOC 4/23/2020 DUANE CLAYTON APPROVED -ENERGY APB ROVED - ENERGY 1 DOCUMENTS -PLAN 24 DOCUMENTS - PLAN 24.pdf 59000 MADISON (BCPR2020-0001) - DOC 4/23/2020 DUANE CLAYTON APPROVED -ENERGY APPROVED -ENERGY 1 DOCUMENTS -PLAN 25 DOCUMENTS - PLAN 25.pdf 59000 MADISON APPROVED- (BCPR2020-0001) - DOC 4/23/2020 DUANE CLAYTON STRUCTURAL APPROVED - CALCULATIONS - PLAN STRUCTURAL 24 CALCULATIONS - PLAN 24.pdf 59000 MADISON APPROVED- (BCPR2020-0001) - DOC 4/23/2020 DUANE CLAYTON STRUCTURAL APPROVED - CALCULATIONS - PLAN STRUCTURAL 25 CALCULATIONS - PLAN 25.pdf 59000 MADISON DOC 4/23/2020 DUANE CLAYTON APPROVED - TRUSS (BCPR2020-0001) - 1 PACKAGE - PLAN 24 APPROVED - TRUSS PACKAGE - PLAN 24.pdf Printed: Wednesday, December 20, 2023 10:27:52 AM 5 of 7 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0001 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 59000 MADISON DOC 4/23/2020 DUANE CLAYTON APPROVED - TRUSS (BCPR2020-0001) - 1 PACKAGE - PLAN 25 APPROVED - TRUSS PACKAGE - PLAN 25.pdf DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - TITLE plan 25_T-24 Calcs.pdf 1 24 (PLAN 25) DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - TITLE Plan 24_T-24 Calcs.pdf 1 24 (PLAN 24) 2ND SUBMITTAL - DOC 4/14/2020 EtrakitContractor STRUCTURAL CALS Plan 24 str Calcs.pdf 1 (PLAN 24) 2ND SUBMITTAL - DOC 4/14/2020 EtrakitContractor STRUCTURAL CALCS Plan 25 Str Calcs.pdf 1 (PLAN 25) DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - ENG Plan 24 and 25 Str 1 RESPONSE Response.pdf DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - ARC Plan 24 and 25 Arch 1 RESPONSE Response.pdf Plan 24 and 25_2nd DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - PLAN Submittal Set 3-27- 1 SET (PLANS 24, 25) 20.pdf DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - Plan 24 Trusses.pdf 1 TRUSS CALC (PLAN 24) DOC 4/14/2020 EtrakitContractor 2ND SUBMITTAL - Plan 25 Trusses.pdf 1 TRUSS CALCS (PLAN 25) La Quinta - 202000965; La Quinta - 202000965; DOC 2/17/2020 INTERWEST BCPP2020-0001- BCPP2020-0001- 0 Invoice 57373.pdf Invoice 57373.pdf DOC 3/5/2020 INTERWEST 202000965(BCPP2020- 202000965(BCPP2020- 0 0001) -1 PC1.docx 0001) -1 PC1.docx Printed: Wednesday, December 20, 2023 10:27:52 AM 6 of 7 ;• CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0001 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/22/2020 INTERWEST 202000965(BCP2020- 202000965(BCP2020- 0 001) PCF.docx 001) PCF.docx La Quinta - 202000965; La Quinta - 202000965; DOC 4/22/2020 INTERWEST BCPP2020-0001- BCPP2020-0001- 0 Invoice 59284.pdf Invoice 59284.pdf REFUND BCPR2020- REFUND BCPR2020- DOC 3/8/2021 LORI LORETT 0001 Nolan Sparks 0001 Nolan Sparks 0 02.25.21 02.25.21.pdf Printed: Wednesday, December 20, 2023 10:27:52 AM 7 of 7 CENTRALSQUARE Invoice No.: 57373 Invoice Date: 2/17/2020 Jurisdiction No.: BCPP2020-0001 Interwest Job No.: 202000965 INTERWEST CONSULTING GROUP Remit to: Interwest Consulting Group P.O. Box 18330 Boulder, CO 80308 Direct questions to: Malia Aipia Powers (916) 512-6812 maipiapowers @interwestgrp. com Residential - Andalusia Country Club - Plan 22 59000 Madison Professional Services for the Period February 1 through February 17. 2020 Bill to: City of La Quinta Attention James "JW" Wiatrak, Building Official 78-495 Calle Tampico La Quinta, CA 92253 Project Hours Total Invoice Total 13 $350.00 Person Title Week End Hours Rate Total Bryan Montes Plan Check Engineer 2/14/2020 2 $125.00 $250.00 Adrienne Peterson ICC Certified Plans Examiner 2/14/2020 1 $100.00 $100.00 Labor 3 $350.00 2018-05-09 Rev.1 Sent to Finance 02.25.21 DEMAND / CHECK REQUEST --J L-- Return check to requestor --- U Mail check Name / Title of person requesting check Lori Lorett / Permit Technician Department individual is associated with: Design & Development Check payable to: Nolan Sparks 750.00 Name Amount: $ _ (Name) (Vendor No.) 81570 Carboneras _ Account Number: 101-0000-42300 (Address) - La Quinta, CA 92253 BCPR2020-0001 — — Project Number: Check description and invoice number: Refund for unused deposit on permit. APPROVED FOR PAYMENT (Finance Department Use Only) BY: Signat -_ BY: - (Department Head) 02.25.2021 (Date) ACCOUNT NO... DESCRIPTION Check mailed 03.05.21 L.L. City of La Quinta VENDOR: 09961 SPARKS, NOLAN DATE ID PO # DESCRIPTION 2/25/2021 022521 02/25/21 - PERMIT DEPOSIT REFUND BCPR2020-0001 PAY TO THE ORDER OF City of La Quinta BANK OF THE WEST 78-495 Calle Tampico 90-78/ 1211 La Quinta, CA 92253 ��llil� �• N- - � r! ---Seven Hundred Fifty Dollars and 00/100 Cents--, �r _. 7. SPARKS, KI I AN - %~ ati^ "Y �. 81570 CARBONERAS C, LA QUINTA, CA 92253- U 1- CHECK NO: 204223 03/05/2021 GL ACCT # AMOUNT 101-0000-42600 750.00 CHECK TOTAL 75000 CHECK NO: 204223 03/05/2021 pAY THIS AMOUNT THIS CHECK EXPIRES AND IS VOID 180 DAYS FROM ISSUE DATE AUT ORIZED SIGNATURE ��� AUTHORIZED SIGNATURE 11' 20t, 2 230 1: 1 2 110078 21: 0059731851118 C uP"zCaD-c)vo DEPOSIT WAS NOT USED AND HAS BEEN DEPOSITED TO THE CASHOVER ACCOUNT, WHICH WILL BE REFUNED BACK TO APPLICANT. THE AMOUNT TO BE REFUNDED IS $750. Financial Information Add I p:E- ReceiptsLIE]l DepoE Irn Ec Unpay Description Qty Amount Comments Paid Receipt In BUILDING TRACT RESIDENTIAL 01/24/20 CONSTRUCTION PLAN DEPOSIT $750.00 CREDIT MR829 101-0000-42600 CARD TECHNOLOGY ENHANCEMENT FEE $5 00 0-1i11i20 g 502-0000-45611 1hEB,3 CREDIT RECORDS MANAGEMENT FEE - MAJOR S21.00 04j" /"0 WEBeo$9 101-0000-42416 CREDIT BUILDING STAFF -PER HOUR -a CASH OVER 101-0000-42300 t Inspections (0) .Add Inspection 11 Add Calendar 11 Set Setluence S1,122.00 $750.00 DEPOSIT REFUND ;SEE NOTES) be fe�uviJed 79„ Ce-pried: S1,89l.00 (� Dtm : u $0.00 0-i23/20 WE64959 --REOIT 02i%1121 DEPOSIT EPOSIT Paid: $1,898,00 Due: $0.00 DESCRIPTION ACCOUNTQTYPAID PermitTRAK $176.00 FSS2020-0014 Address: 81730 ANDALUSIA Apn: 764670006 $176.00 FIRE FEES $161.00 FIRE SPRINKLER SYSTEMS -SINGLE FAMILY DETACHED 101-0000-42421 0 $161.00 RECORDS MANAGEMENT FEE $10.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 TECHNOLOGY ENHANCEMENT FEE $5.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 ProjectTRAK $3,000.00 BCPR2020-0001 Address: 59000 MADISON ST Apn: 764700011 $750.00 BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00 BUILDING TRACT RESIDENTIAL 101-0000-42600 1 $750.00 CONSTRUCTION PLAN DEPOSIT BCPR2020-0002 Address: 59000 MADISON ST Apn: 764700011 $750.00 BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00 BUILDING TRACT RESIDENTIAL 101-0000-42600 1 $750.00 CONSTRUCTION PLAN DEPOSIT BCPR2020-0003 Address: 59000 MADISON ST Apn: 764700011 $750.00 BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00 BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT 101-0000-42600 1 $750.00 BCPR2020-0004 Address: 59000 MADISON ST Apn: 764700011 $750.00 BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT $750.00 BUILDING TRACT RESIDENTIAL CONSTRUCTION PLAN DEPOSIT 101-0000-42600 1 $750.00 • 1 1 Date Paid: Friday, January 24, 2020 Paid By: NOLAN SPARKS Cashier: AHI Pay Method: CREDIT CARD 867270 Printed: Thursday, February 25, 20219:12 AM 1 of 1 hub: BUILDING ENERGY ANALYSIS REPORT I PROJECT: PLAN # 24 59000 MADISON ANDALUSIA C.C. LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 760 340.3528 Report Prepared by: TITLE 24 OF THE DESERT SERVICES INC. title24ofthedesert@gmail.com 760 278.1840, CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 04/23/2020 �—D C Job Number: 20 - GLS /001 - 002 - 2R Date: 3/19/2020 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 20 HVAC System Heating and Cooling Loads Summary 22 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 1 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x GENERAL INFORMATION 01 Project Name PLAN 24 ANDALUSIA 02 Run Title Title 24 Analysis 03 Project Location 59000 MADISON ANDALUSIA C.C. 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92270 07 Software Version EnergyPro 8.0 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) AIIOrientations 10 Building Type SingleFamily 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 New Cond. Floor Area (ft) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.29 18 Total Cond. Floor Area (ftZ) 4184 19 Glazing Percentage (%) 23.77% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 2 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x ENERGY DESIGN RATING Energy Design Ratings Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 46.1 23 Proposed Designs North Facing 43.6 20.6 2.5 2.4 East Facing 44.1 21 2 2 South Facing 41 17.9 5.1 5.1 West Facing 44.9 21.9 1.2 1.1 RESULT: 3: COMPLIES ► Efficiency EDR includes improvements to the building envelope and more efficient equipment Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc. s Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 7.09 kWdc • Proposed PV Capacity Scaling: North (7.09 kWdc) East (7.09 kWdc) South (7.09 kWdc) West (7.09 kWdc) Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 3 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x ENERGY USE SUMMARY Energy Use (kTDWft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.67 2.9 -1.23 -73.7 Space Cooling 81.83 73.08 8.75 10.7 IAQ Ventilation 2.19 2.19 0 0 Water Heating 5.1 6.15 -1.05 -20.6 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 90.79 84.32 6.47 7.1 Space Heating 1.67 3.37 -1.7 -101.8 Space Cooling 81.83 73.76 8.07 9.9 IAQ Ventilation 2.19 2.19 0 0 Water Heating 5.1 6.15 -1.05 -20.6 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 90.79 rftr:DT 85.47 5.32 5.9 Space Heating 1.67 2.32 -0.65 -38.9 Space Cooling 81.83 S P R 66.63 15.2 18.6 IAQ Ventilation 2.19 2.19 0 0 Water Heating 5.1 6.15 -1.05 -20.6 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 90.79 77.29 13.5 14.9 Space Heating 1.67 2.48 -0.81 -48.5 Space Cooling 81.83 76.95 4.88 6 IAQ Ventilation 2.19 2.19 0 0 Water Heating 5.1 6.15 -1.05 -20.6 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 90.79 87.77 3.02 3.3 REQUIRED PV SYSTEMS 01 02 03 04 05 06 1 07 1 08 09 10 11 Registration Number: Registration Date/Time: HERS Provider: 220-P010012257B-000-000-0000000-0000 2020-03-19 11:59:55 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 4 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x DC System Size Exception Module Type Array Type Power Electronics CFI Azimuth Tilt Array Angle Tilt: (x in 12) Inverter Eff. (kWdc) (deg) Input (deg) N 7.09 NA Standard Fixed (roof none true n/a n/a n/a n/a 96 mount) REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • PV System: 7.09 kWdc • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation • Kitchen range hood i InL. Cooling System Verifications: CaICERTS, • Minimum Airflow • Verified EER Ilk H E R S P R O V I D E R • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name z Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems PLAN 24 ANDALUSIA 4184 1 4 4 0 1 Registration Number: Registration Date/Time: HERS Provider: 220-P010012257B-000-000-0000000-0000 2020-03-19 11:59:55 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 5 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Z1- 1655 Conditioned AC-1 -1 1655 10 DHW Sys 1 N/A Z2 - 1523 Conditioned AC-2 -2 1523 10 DHW Sys 1 N/A Z3 - 479 Conditioned AC-3 -3 479 10 DHW Sys 1 N/A Z4 - 527 Conditioned AC-4 -4 527 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) N - 802 Z1- 1655 R-21 Wall 0 Front 802 80.5 90 E - 240 Z1- 1655 R-21 Wall 180 Back 240 14.436 90 S - 205 Z1- 1655 R-21 Wall 180 Back 205 72 90 W -240 Z1- 1655 R-21 Wall 270 Right 240 96 90 N - 175 Z2 - 1523 R-21 Wall 0 Front 175 126 90 E - 106 Z2 - 1523 R-21 Wall 180 Back 106 24 90 S - 487 Z2 - 1523 R-21 Wall 180 Back 487 55.5 90 W - 409 Z2 - 1523 R-21 Wall 270 Right 409 332 90 N - 122 Z3 - 479 R-21 Wall 0 Front 122 103.996 90 E - 65 Z3 - 479 R-21 Wall 90 Left 65 4.5 90 S - 173 Z3 - 479 R-21 Wall 180 Back 173 4.5 90 N - 253 Z4 - 527 R-21 Wall 0 Front 253 9 90 W - 204 Z4 - 527 R-21 Wall 270 Right 204 72 90 1655 Z1-1655 R-38 + R-21- n/a n/a 1655 n/a n/a 1523 Z2 - 1523 R-38 + R-21 n/a n/a 1523 n/a n/a 479 Z3 - 479 R-38 + R-21 n/a n/a 479 n/a n/a Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 6 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) 527 Z4 - 527 R-38 + R-21 -- n/a n/a 527 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Z1- 1655 Attic RoofZ1- 1655 Ventilated 4 0.1 0.85 No No Attic Z2 - 1523 Attic RoofZ2 - 1523 Ventilated 4 0.1 0.85 No No Attic Z3 - 479 Attic RoofZ3 - 479 Ventilated 4 0.1 0.85 No No Attic Z4 - 527 Attic RoofZ4 - 527 Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 2056 - 21 Window N - 802 Front 0 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 2056 - 22 Window N - 802 Front 0 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 23 Window N - 802 Front 0 3 5.5 1 16.5 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 24 Window N - 802 Front 0 3 5.5 1 16.5 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 25 Window N - 802 Front 0 3 5.5 1 16.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 26 Window N - 802 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 27 Window N - 802 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 2050 - 28 Window E - 240 Back 180 12 12 0 9.94 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 29 Window E - 240 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 9080 - 30 Window S - 205 Back 180 9 8 1 72 0.29 NFRC 0.2 NFRC Bug Screen 12080 - 31 Window W - 240 Right 270 12 8 1 96 0.29 NFRC 0.2 NFRC Bug Screen 1061200 - 10 Window N - 175 Front 0 10.5 12 1 126 0.29 NFRC 0.2 NFRC Bug Screen Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 7 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 3080 - 7 Window E - 106 Back 180 3 8 1 24 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 15 Window S - 487 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 14 Window S - 487 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 13 Window S - 487 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 11 Window S - 487 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 12 Window S - 487 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 17 Window S - 487 Back 180 3 5.5 1 16.5 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 18 Window S - 487 Back 180 3 5.5 1 16.5 0.29 NFRC 0.2 NFRC Bug Screen 80100 - 19 Window W - 409 Right 270 8 10 1 80 0.29 NFRC 0.2 NFRC Bug Screen 210120 - 20 Window W - 409 Right 270 8 10 3 252 0.29 NFRC 0.2 NFRC Bug Screen 9080 -18 Window N - 122 Front 0 9 8 1 72 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 27 2 Window N - 122 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 5056 - 5 Window N - 122 Front 0 5 5.6 0 27.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 6 Window E - 65 Left 90 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 16 Window S - 173 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 1 Window N - 253 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 2 Window N - 253 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 6080 - 3 Window W - 204 Right 270 6 8 1 48 0.29 NFRC 0.2 NFRC Bug Screen 3080 - 4 Window W - 204 Right 270 3 1 8 1 24 0.29 NFRC 0.2 NFRC Bug Screen Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 8 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 2056 - 21 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2056 - 22 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 23 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 24 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 25 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 26 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 27 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2050 - 28 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 29 2 0.1 2 2 0 0 0 0 0 0 0 0 0 9080 - 30 2 0.1 2 2 0 0 0 0 0 0 0 0 0 12080 - 31 12 0.1 12 12 0 0 0 0 0 0 0 0 0 1061200 - 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3080 - 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 9 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 1630 - 12 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 80100 - 19 2 0.1 2 2 0 0 0 0 0 0 0 0 0 210120-20 18 0.1 18 18 0 0 0 0 0 0 0 0 0 9080 -18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630-272 2 0.1 2 2 0 0 0 0 0 0 0 0 0 5056 - 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630-6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 1 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630-2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 6080 - 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3080 - 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 10 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Carpeted Fraction Heated 16552 Z1- 1655 1655 0.1 None 80% No 15232 Z2 - 1523 1523 0.1 None 80% No 4792 Z3 - 479 479 0.1 None 80% No 264 Z4 - 527 264 0.1 None 80% No 263 Z4 - 527 263 0.1 None 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-0 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. 0. C. R-0 None / None 0.277 Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ1- 1655 Attic Roofs 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 11 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ2 - 1523 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ3 - 479 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Wood Framed t r� im Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Attic RoofZ4 - 527 Attic Roofs Ceiling 2x4 @ 24 in. 0. - None / None 0.055 Siding/sheathing/decking a s i � ! s Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Ceilings (below Wood Framed Over Ceiling Joists: R-28.9 insul. R-38 + R-21 - attic) Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.025 Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 12 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Fraction (%) Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2) 0 None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Vol. Factor or or Recovery Brand or Model / Type Units (gal) Efficiency or Pilot R-value Eff. or Flow Rate Other Ambient Condition (Int/Ext) DHW Heater 1 Natural Gas Consumer 2 0 0.92-UEF 200000- 0 n/a n/a n/a n/a Instantaneous Btu/Hr WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Cooling Unit Fan Name Distribution Name Required Heating Cooling Name Name Thermostat Type Equipment Count Equipment Count AC-1 -1 Heat pump Heat Pump System Heat Pump System HVAC Fan 1 Air Distribution Setback 1 1 heating cooling 1 1 System 1 AC-2 -2 Heat pump Heat Pump System Heat Pump System HVAC Fan 2 Air Distribution Setback 1 1 heating cooling 2 2 System 2 Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 13 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Cooling Unit Fan Name Distribution Name Required Heating Cooling Name Name Thermostat Type Equipment Count Equipment Count AC-3 -3 Heat pump Heat Pump System Heat Pump System HVAC Fan 3 Air Distribution Setback 1 1 heating cooling 3 3 System 3 AC-4 -4 Heat pump Heat Pump System Heat Pump System HVAC Fan 4 Air Distribution Setback 1 1 heating cooling 4 4 System 4 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 1-hers-htpump Heat Pump System 2 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 2-hers-htpump Heat Pump System 3 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 3-hers-htpump Heat Pump System 4 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 4-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 355 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 355 Required Required Yes Yes Yes Yes 2-hers-htpump Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 14 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 355 Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Required 355 Required Required Yes Yes Yes Yes 4-hers-htpump HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 1 05 06 07 08 1 09 10 11 12 Duct Ins. Duct Location Surface Area R-value Name Type Design Type Supply Return supply Return Supply Return Bypass Duct Leaka a HERS Verification Duct Air Distribution No Sealed and Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 Tested 1-hers-dist Duct Air Distribution No Sealed and Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 2 Tested 2-hers-dist Duct Air Distribution No Sealed and Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 3 Tested 3-hers-dist Duct Air Distribution No Sealed and Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 4 Tested 4-hers-dist Duct Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 15 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 ( 65 LOTS).ribdl9x HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification target (%) Location Design Ducts Handler Conditioned Space Air Distribution Yes 5 Not Required Not Required Not Required Credit not taken Not Required No System 1-hers-dirt Air Distribution Yes 5 Not Required Not Required Not Required Credit not taken Not Required No System 2-hers-dirt Air Distribution Yes 5 Not Required Not Required Not Required Credit not taken Not Required No System 3-hers-dirt Air Distribution Yes 5 Not Required Not Required Not Required Credit not taken Not Required No System 4-hers-dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.5 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.5 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.5 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.5 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.5 HVAC Fan 2-hers-fan Required 0.5 Registration Number: 220-P010012257B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 11:59:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 11:46:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 16 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 3-hers-fan Required 0.5 HVAC Fan 4-hers-fan Required 0.5 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) HERS Verification SFam IAQVentRpt 155 0.25 Default 0 Yes � CaICERTS, InL. Registration Number: 220-P010012257B-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2019 Residential Compliance Registration Date/Time: 2020-03-19 11:59:55 Report Version: 2019.1.100 Schema Version: rev 20190401 HERS Provider: CaICERTS inc. Report Generated: 2020-03-19 11:46:58 CERTIFICATE OF COMPLIANCE Project Name: PLAN 24 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T11:43:52-07:00 (Page 17 of 17) Input File Name: 2R - 002 - ANDALUSIA - PLAN 24 (65 LOTS).ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ -� Company: Signature Date: TITLE 24 OF THE DESERT 2020-03-19 11:59:30 Address: CEA/ HERS Certification Identification (If applicable): 74800 shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Ruben Romero Responsible Designer Signature: � Company: Date Signed: GLS ARCHITECTURE GROUP INC 2020-03-19 11:59:55 Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: Registration Date/Time: 220-P010012257B-000-000-0000000-0000 2020-03-19 11:59:55 CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Schema Version: rev 20190401 HERS Provider: Easy to Verify at CaICERTS.com CaICERTS inc. Report Generated: 2020-03-19 11:46:58 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 24 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 311912020 Project Address 59000 MADISON ANDALUSIA C.C. LA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,184 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 38 4,184 Add=R-21.0 New Slab Unheated Slab -on -Grade - no insulation 4,184 Perim = 0' New Wall Wood Framed R 21 2,846 New Demising Wood Framed - no insulation 220 New FENESTRATION Orientation Area(ft2) Total Area: 995 Glazing Percentage: 23.8% New/Altered Average U-Factor: 0.29 U-Fac SHGC Overhang Sidefins Exterior Shades Status Front (N) 319.5 0.290 0.20 2.0 none N/A New Rear (S) 170.5 0.290 0.20 2.0 none N/A New Right (W) 96.0 0.290 0.20 12.0 none N/A New Right (W) 152.0 0.290 0.20 2.0 none N/A New Right (W) 252.0 0.290 0.20 18.0 none N/A New Left (E) 4.5 0.290 0.20 2.0 none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status AC-1 - Ducted Ducted Attic 8.0 New AC-2 - Ducted Ducted Attic 8.0 New AC-3 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Instantaneous Gas 0 0.92 Standard New EnegyP,, 8.0 by EnergySoft User Number. 20648 ID: 20 - GLS /001 - 002 - Page 20 of 25 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 24 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 311912020 Project Address 59000 MADISON ANDALUSIA C.C. LA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,184 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: 995 Glazing Percentage: 23.8% New/Altered Average U-Factor: 0.29 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status AC-4 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EegyP,, 8.0 by EnerqySoft User Number. 20648 ID: 20 - GLS /001 - 002 - Page 21 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 24 Date 3/19/2020 System Name AC-1 - Floor Area 1,655 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 922 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 18,162 562 305 12,213 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 23.6 1,048 467 Cooling System 0 0 Output per System 48,000 0 0 0 0 Total Output (Btuh) 48,000 1,489 562 -1,489 Total Output (Tons) 4.0 1,048 467 Total Output Btuh/sgft 29.0 Total Output s ft/Ton 413.8 1 21,747 11,658 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 4 TON 16/13/9.5 40,466 0 24,358 Airflow cfm/sgft 0.97 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 40,466 0 24,358 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 68 OF 68 OF 105 OF 106 OF -Il I I I Heating Coil Supply Fan 1,600 cfm 106 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62OF 55/54OF 56/54OF Cooling Coil Supply Fan 56 / 54 OF 1,600 cfm 46.4% ROOM 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 24 Date 3/19/2020 System Name AC-2 - Floor Area 1,523 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 991 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 22,472 517 297 13,425 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 25.6 1,297 513 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output (Btuh) 60,000 1,489 517 -1,489 Total Output (Tons) 5.0 1,297 513 Total Output Btuh/sgft 39.4 Total Output s ft/Ton 304.6 1 26,555 12,963 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 5 TON 16/13/9.5 49,456 0 24,358 Airflow cfm/sgft 1.31 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 49,456 0 24,358 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air -4 r- 0 cfm 68 OF 68 OF 110 OF 111 OF fir E Heating Coil Supply Fan 2,000 cfm 110 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76/60°F 76/60°F 52/51 OF 53/51 OF Cooling Coil Supply Fan 54 / 52 OF 2,000 cfm 41.6% ROOM 75/60°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 24 Date 3/19/2020 System Name AC-3 - Floor Area 479 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 258 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 5,671 163 115 3,673 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 81.4 327 140 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output (Btuh) 24,000 1,489 163 -1,489 Total Output (Tons) 2.0 327 140 Total Output Btuh/sgft 50.1 Total Output s ft/Ton 239.5 1 7,815 2,465 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 2TON 16/13/9.5 19,730 0 24,358 Airflow cfm/sgft 1.67 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 19,730 0 24,358 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 68 OF 68 OF 96 OF ^ 98 OF I - a110 r - - Heating Coil Supply Fan 800 cfm 98 OF IROIOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 75/60°F 75/60°F 52/51 OF 54/52°F Cooling Coil Supply Fan 54 / 52 OF 800 cfm 41.3% ROOM 75/60°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 24 Date 3/19/2020 System Name AC-4 - Floor Area 527 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 349 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 7,586 179 119 3,816 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 74.0 438 146 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output (Btuh) 24,000 1,489 179 -1,489 Total Output (Tons) 2.0 438 146 Total Output Btuh/sgft 45.5 Total Output s ft/Ton 263.5 1 9,951 2,619 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 2TON 16/13/9.5 19,759 0 24,358 Airflow cfm/sgft 1.52 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 19,759 0 24,358 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 68 OF 68 OF 96 OF ^ 98 OF I - a110 r - - Heating Coil Supply Fan 800 cfm 98 OF IROIOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 60 IF 76/60OF 52/51 OF 54/52OF Cooling Coil Supply Fan 55 / 52 OF 800 cfm 41.5% ROOM Iff 75 / 60 OF I BUILDING ENERGY ANALYSIS REPORT I PROJECT: PLAN # 25 59000 MADISON ANDALUSIA C.C. LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 760 340.3528 Report Prepared by: TITLE 24 OF THE DESERT SERVICES INC. title24ofthedesert@gmail.com 760 278.1840, CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 04/23/2020 r)�D C Job Number: 20 - GLS /001 - 005 - 2R Date: 3/19/2020 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 21 Form MF-1 R Mandatory Measures Summary 23 HVAC System Heating and Cooling Loads Summary 27 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 1 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x GENERAL INFORMATION 01 Project Name PLAN 25 ANDALUSIA 02 Run Title Title 24 Analysis 03 Project Location 59000 MADISON ANDALUSIA C.C. 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.0 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) AIIOrientations 10 Building Type SingleFamily 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 3 14 New Cond. Floor Area (ft) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.29 18 Total Cond. Floor Area (ftZ) 4502 19 Glazing Percentage (%) 29.57% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 2 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x ENERGY DESIGN RATING Energy Design Ratings Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 45 23.3 Proposed Designs North Facing 45 23.2 0 0.1 East Facing 42.2 20.5 2.8 2.8 South Facing 43 21.2 2 2.1 West Facing 41.8 20.1 3.2 3.2 RESULT: 3: COMPLIES ► Efficiency EDR includes improvements to the building envelope and more efficient equipment Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc. s Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 8.13 kWdc • Proposed PV Capacity Scaling: North (8.13 kWdc) East (8.13 kWdc) South (8.13 kWdc) West (8.13 kWdc) Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 3 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x ENERGY USE SUMMARY Energy Use (kTDWft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.94 6.21 -1.27 -25.7 Space Cooling 98.79 96.48 2.31 2.3 IAQ Ventilation 1.67 1.67 0 0 Water Heating 4.45 5.43 -0.98 -22 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 109.85 109.79 0.06 0.1 Space Heating 4.94 6.78 -1.84 -37.2 Space Cooling 98.79 87.71 11.08 11.2 IAQ Ventilation 1.67 1.67 0 0 Water Heating 4.45 5.43 -0.98 -22 Self Utilization Credit n/a =111111110M 0 0 n/a East Facing Compliance Total 109.85 101.59 8.26 7.5 Space Heating 4.94 6.31 -1.37 -27.7 Space Cooling 98.79 S R k-1 90.53 8.26 8.4 IAQ Ventilation 1.67 1.67 0 0 Water Heating 4.45 5.43 -0.98 -22 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 109.85 103.94 5.91 5.4 Space Heating 4.94 5.8 -0.86 -17.4 Space Cooling 98.79 87.56 11.23 11.4 IAQ Ventilation 1.67 1.67 0 0 Water Heating 4.45 5.43 -0.98 -22 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 109.85 100.46 9.39 8.5 REQUIRED PV SYSTEMS 01 02 03 04 05 06 1 07 1 08 09 10 11 Registration Number: Registration Date/Time: HERS Provider: 220-P010012440B-000-000-0000000-0000 2020-03-19 15:20:02 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 4 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x DC System Size Exception Module Type Array Type Power Electronics CFI Azimuth Tilt Array Angle Tilt: (x in 12) Inverter Eff. (kWdc) (deg) Input (deg) N 8.13 NA Standard Fixed (roof none true n/a n/a n/a n/a 96 mount) REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • PV System: 8.13 kWdc • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation • Kitchen range hood i InL. Cooling System Verifications: CaICERTS, • Minimum Airflow • Verified EER Ilk H E R S P R O V I D E R • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: Registration Date/Time: HERS Provider: 220-P010012440B-000-000-0000000-0000 2020-03-19 15:20:02 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 5 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftz) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems PLAN 25 ANDALUSIA 4502 1 3 4 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Z1- 897 Conditioned AC-1 -1 897 10 DHW Sys 1 N/A Z2 - 1187 Conditioned AC-2 -2 1187 10 DHW Sys 1 N/A Z3 - 1856 Conditioned AC-3 -3 1856 10 DHW Sys 1 N/A Z4 - 562 Conditioned AC-4 -4 562 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) N - 242 Z1- 897 R-21 Wall 0 Front 242 13.5 90 E - 150 Z1- 897 R-21 Wall 90 Left 228 22 90 S - 270 Z1- 897 R-21 Wall 180 Back 270 49.5 90 W - 150 Z1- 897 R-21 Wall 270 Right 256.1 256 90 N - 140 Z2 - 1187 R-21 Wall 0 Front 140 35.2687 90 S - 562 Z2 - 1187 R-21 Wall 180 Back 562 77.739 90 W - 165 Z2 - 1187 R-21 Wall 270 Right 165 96 90 N - 580 Z3 - 1856 R-21 Wall 0 Front 580 107.5 90 E - 440 Z3 - 1856 R-21 Wall 90 Left 440 228 90 S - 130 Z3 - 1856 R-21 Wall 180 Back 130 0 90 Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 6 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) W - 495 Z3 - 1856 R-21 Wall 270 Right 495 288.015 90 N - 292 Z4 - 562 R-21 Wall 0 Front 292 60.5055 90 E- 205 Z4 - 562 R-21 Wall 90 Left 205 25.14 90 S- 292 Z4-562 R-21 Wall 180 Back 292 24 90 W -205 Z4-562 R-21 Wall 270 Right 205 48 90 897 Z1- 897 R-38 + R-21 n/a n/a 897 n/a n/a 1187 Z2 - 1187 R-38 + R-21 n/a n/a 1187 n/a n/a 1856 Z3 - 1856 R-38 + R-21 n/a n/a 1856 n/a n/a 562 Z4 - 562 R-38 + R-21 n/a n/a 562 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Z1- 897 Attic RoofZ1- 897 Ventilated 4 0.1 0.85 No No Attic Z2 - 1187 Attic RoofZ2 - 1187 Ventilated 4 0.1 0.85 No No Attic Z3 - 1856 Attic RoofZ3 - 1856 Ventilated 4 0.1 0.85 No No Attic Z4 - 562 Attic RoofZ4 - 562 Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading 1630 - 30 Window N - 242 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 31 Window N - 242 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 31 2 Window N - 242 Front 0 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 4056 - 33 Window E - 150 Left 90 4 5.5 1 22 0.29 NFRC 0.2 NFRC Bug Screen Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 7 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 2056 - 34 Window S - 270 Back 180 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 2056 - 35 Window S - 270 Back 180 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 5056 - 36 Window S - 270 Back 180 5 5.5 1 27.5 0.29 NFRC 0.2 NFRC Bug Screen (3) 2880 - 11 Window W - 150 Right 270 8 8 1 64 0.29 NFRC 0.2 NFRC Bug Screen 160120 - 10 Window W - 150 Right 270 16 12 1 192 0.29 NFRC 0.2 NFRC Bug Screen 2656 - 9 Window N - 140 Front 0 2.5 5.5 0 11.76 0.29 NFRC 0.2 NFRC Bug Screen 2656 - 10 Window N - 140 Front 0 2.5 5.5 0 11.76 0.29 NFRC 0.2 NFRC Bug Screen 2656 - 11 Window N - 140 Front 0 2.5 5.5 0 11.76 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 17 Window S - 562 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 2656 - 16 Window S - 562 Back 180 2.5 5.5 1 13.75 0.29 NFRC 0.2 NFRC Bug Screen 2656 - 15 Window S - 562 Back 180 2.5 5.5 1 13.75 0.29 NFRC 0.2 NFRC Bug Screen 2656 - 14 Window S - 562 Back 180 2.5 5.5 1 13.75 0.29 NFRC 0.2 NFRC Bug Screen 1630 - 13 Window S - 562 Back 180 1.5 3 1 4.5 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 19 Window S - 562 Back 180 3 5.5 0 13.74 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 18 Window S - 562 Back 180 3 5.5 0 13.74 0.29 NFRC 0.2 NFRC Bug Screen 12080 - 28 Window W - 165 Right 270 12 8 1 96 0.29 NFRC 0.2 NFRC Bug Screen 9080 - 23 Window N - 580 Front 0 9 8 1 72 0.29 NFRC 0.2 NFRC Bug Screen 2020 - 20 Window N - 580 Front 0 2 2 1 4 0.29 NFRC 0.2 NFRC Bug Screen 2020 - 21 Window N - 580 Front 0 2 2 1 4 0.29 NFRC 0.2 NFRC Bug Screen 5056 - 22 Window N - 580 Front 0 5 5.5 1 27.5 0.29 NFRC 0.2 NFRC Bug Screen 90120 - 24 Window E - 440 Left 90 9 12 1 108 0.29 NFRC 0.2 NFRC Bug Screen 3080 RND TOP - 25 Window E - 440 Left 90 3 10 1 48 0.29 NFRC 0.2 NFRC Bug Screen 9080 - 12 Window E - 440 Left 90 9 8 1 72 0.29 NFRC 0.2 NFRC Bug Screen 10080 - 27 Window W - 495 Right 270 10 8 1 80 0.29 NFRC 0.2 NFRC Bug Screen Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 8 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 174120 - 29 Window W - 495 Right 270 17.3 12 1 208.0 0.29 NFRC 0.2 NFRC Bug Screen 5056 - 33 Window N - 292 Front 0 3 5.5 1 27.51 0.29 NFRC 0.2 NFRC Bug Screen 2056 - 1 Window N - 292 Front 0 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 2056 - 2 Window N - 292 Front 0 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 2056 - 3 Window N - 292 Front 0 2 5.5 1 11 0.29 NFRC 0.2 NFRC Bug Screen 4056 - 5 Window E- 205 Left 90 4 5.5 1 22 0.29 NFRC 0.2 NFRC Bug Screen 24 RND FG - 6 Window E- 205 Left 90 1 2.5 1 3.14 0.29 NFRC 0.2 NFRC Bug Screen 3080 - 24 Window S- 292 Back 180 3 8 1 24 0.29 NFRC 0.2 NFRC Bug Screen 6080 - 7 Window W - 205 Right 270 6 8 1 48 0.29 NFRC 0.2 NFRC Bug Screen OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 1630 - 30 8 0.1 8 8 0 0 0 0 0 0 0 0 0 1630-31 8 0.1 8 8 0 0 0 0 0 0 0 0 0 1630-312 8 0.1 8 8 0 0 0 0 0 0 0 0 0 4056 - 33 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2056 - 34 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2056 - 35 2 0.1 2 2 0 0 0 0 0 0 0 0 0 5056 - 36 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 9 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up (3) 2880 - 11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 160120 - 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2656 - 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2656 - 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2656 - 11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2656 - 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2656 - 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2656 - 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1630 - 13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 19 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3056 - 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 12080 - 28 12 0.1 12 12 0 0 0 0 0 0 0 0 0 9080 - 23 30 0.1 30 30 0 0 0 0 0 0 0 0 0 2020 - 20 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2020 - 21 2 0.1 2 2 0 0 0 0 0 0 0 0 0 5056 - 22 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 10 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 90120 - 24 12 0.1 12 12 0 0 0 0 0 0 0 0 0 3080 RND TOP - 25 2 0.1 2 2 0 0 0 0 0 0 0 0 0 9080 - 12 10 0.1 10 10 0 0 0 0 0 0 0 0 0 10080 - 27 2 0.1 2 2 0 0 0 0 0 0 0 0 0 174120 - 29 18 0.1 18 18 0 0 0 0 0 0 0 0 0 5056 - 33 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2056 - 1 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2056 - 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2056 - 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 4056 - 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 24RNDFG-6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 3080 - 24 8 0.1 8 8 0 0 0 0 0 0 0 0 0 6080 - 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Carpeted Fraction Heated 8972 Z1- 897 897 0.1 None 80% No Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 11 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Carpeted Fraction Heated 11872 Z2 - 1187 1187 0.1 None 80% No 18562 Z3 - 1856 1856 0.1 None 80% No 562 2 Z4 - 562 562 0.1 None 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-0 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. 0. C. R-0 None / None 0.277 Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Attic RoofZ1- 897 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Attic RoofZ2 - 1187 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 20 Around Roof Joists: R-8.0 insul. Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 12 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ3 - 1856 Attic Roofs 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ4 - 562 Attic Roofs 2x4 @ 24 in. 0. C. R-21 None / None 0.055 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-8.0 insul. Ceilings (below Wood Framed Over Ceiling Joists: R-28.9 insul. R-38 + R-21 -- attic) Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.025 Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Fraction (%) Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2) 0 None n/a Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 13 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Vol. Factor or or Recovery Brand or Model / Type Units (gal) Efficiency or Pilot R-value Eff. or Flow Rate Other Ambient Condition (Int/Ext) DHW Heater 1 Natural Gas Consumer 2 0 0.92-UEF 200000 0 n/a n/a n/a n/a Instantaneous Btu/Hr WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating Unit Cooling Unit Required Heating Cooling Name System Type Name Name Fan Name Distribution Name Thermostat Type Equipment Count Equipment Count AC-1 -1 Heat pump Heat Pump System Heat Pump System HVAC Fan 1 Air Distribution Setback 1 1 heating cooling 1 1 System 1 AC-2 -2 Heat pump Heat Pump System Heat Pump System HVAC Fan 2 Air Distribution Setback 1 1 heating cooling 2 2 System 2 AC-3 -3 Heat pump Heat Pump System Heat Pump System HVAC Fan 3 Air Distribution Setback 1 1 heating cooling 3 3 System 3 AC-4 -4 Heat pump Heat Pump System Heat Pump System HVAC Fan 4 Air Distribution Setback 1 1 heating cooling 4 4 System 4 Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 14 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 1 9.5 60000 45000 16 13 Not Zonal Single Heat Pump System Speed 1-hers-htpump Heat Pump System 2 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 2-hers-htpump Heat Pump System 3 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 3-hers-htpump Heat Pump System 4 Central split HP 1 9.5 39000 35500 16 13 Not Zonal Single Heat Pump System Speed 4-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 360 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 360 Required Required Yes Yes Yes Yes 2-hers-htpump Heat Pump System Required 360 Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Required 360 Required Required Yes Yes Yes Yes 4-hers-htpump Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 15 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 1 05 06 07 08 1 09 10 11 12 Duct Ins. Duct Location Surface Area R-value Name Type Design Type Supply Return Supply Return SuPPIY Return Bypass Duct Leaka a HERS Verification Duct Air Distribution No Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 1-hers-dist Duct Air Distribution No Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 2 2-hers-dist Duct Air Distribution No Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 3 3-hers-dist Duct Air Distribution No Air Distribution System Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 4 4-hers-dist Duct HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification target (%) Location Design g Ducts Handler Conditioned Space Air Distribution Yes 3 Not Required Not Required Not Required Credit not taken Required No System 1-hers-dirt Air Distribution Yes 3 Not Required Not Required Not Required Credit not taken Required No System 2-hers-dist Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 16 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification target (%) Location Design Ducts Handler Conditioned Space Air Distribution Yes 3 Not Required Not Required Not Required Credit not taken Required No System 3-hers-dirt Air Distribution Yes 3 Not Required Not Required Not Required Credit not taken Required No System 4-hers-dirt HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.5 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.5 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.5 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.5 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.5 HVAC Fan 2-hers-fan Required 0.5 HVAC Fan 3-hers-fan Required 0.5 HVAC Fan 4-hers-fan Required 0.5 Registration Number: 220-P010012440B-000-000-0000000-0000 Registration Date/Time: 2020-03-19 15:20:02 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Report Generated: 2020-03-19 15:07:58 Schema Version: rev 20190401 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 17 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) HERS Verification SFam IAQVentRpt 1-1 110 0.0727273 Default 0 Yes SFam IAQVentRpt 2-1 110 0.0727273 Default 0 Yes SFam IAQVentRpt 3-1 110 0.0727273 Default 0 Yes SFam IAQVentRpt 4-1 110 0.0727273 Default 0 Yes � CaICERTS, Inc. Registration Number: 220-P010012440B-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2019 Residential Compliance Registration Date/Time: 2020-03-19 15:20:02 Report Version: 2019.1.100 Schema Version: rev 20190401 HERS Provider: CaICERTS inc. Report Generated: 2020-03-19 15:07:58 CERTIFICATE OF COMPLIANCE Project Name: PLAN 25 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2020-03-19T15:04:23-07:00 (Page 18 of 18) Input File Name: 2R - 005 - ANDALUSIA - PLAN 25 (65 LOTS).ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ -� Company: Signature Date: TITLE 24 OF THE DESERT 2020-03-19 15:19:21 Address: CEA/ HERS Certification Identification (If applicable): 74800 shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Ruben Romero Responsible Designer Signature: � Company: Date Signed: GLS ARCHITECTURE GROUP INC 2020-03-19 15:20:02 Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: Registration Date/Time: 220-P010012440B-000-000-0000000-0000 2020-03-19 15:20:02 CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.100 Schema Version: rev 20190401 HERS Provider: J, �_ Easy to Verify at CaICERTS.com CaICERTS inc. Report Generated: 2020-03-19 15:07:58 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 25 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 311912020 Project Address 59000 MADISON ANDALUSIA C.C. LA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,502 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 38 4,502 Add=R-21.0 New Slab Unheated Slab -on -Grade - no insulation 4,502 Perim = 0' New Wall Wood Framed R 21 3,685 New Demising Wood Framed - no insulation 220 New FENESTRATION Orientation Area(ft2) Total Area: 1,331 Glazing Percentage: 29.6% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.29 Exterior Shades Status Front (N) 13.5 0.290 0.20 8.0 none N/A New Left (E) 95.1 0.290 0.20 2.0 none N/A New Rear (S) 127.3 0.290 0.20 2.0 none N/A New Right (W) 384.0 0.290 0.20 2.0 none N/A New Front (N) 103.8 0.290 0.20 2.0 none N/A New Right (W) 96.0 0.290 0.20 12.0 none N/A New Front (N) 72.0 0.290 0.20 30.0 none N/A New Front (N) 27.5 0.290 0.20 18.0 none N/A New Left (E) 108.0 0.290 0.20 12.0 none N/A New Left (E) 72.0 0.290 0.20 10.0 none N/A New Right (W) 208.0 0.290 0.20 18.0 none N/A New Rear (S) 24.0 0.290 0.20 8.0 none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status AC-1 - Ducted Ducted Attic 8.0 New AC-2 - Ducted Ducted Attic 8.0 New AC-3 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Instantaneous Gas 0 0.92 Standard New EnegyP,, 8.0 by EnergySoft User Number. 20648 ID: 20 - GLS /001 - 005 - Page 21 of 30 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 25 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 311912020 Project Address 59000 MADISON ANDALUSIA C.C. LA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,502 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: 1,331 Glazing Percentage: 29.6% New/Altered Average U-Factor: 0.29 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status AC-4 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EegyP,, 8.0 by EnerqySoft User Number. 20648 ID: 20 - GLS /001 - 005 - Page 22 of 30 2019 Low -Rise Residential Mandatory Measures Summary NOTE. -Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (Original 08/2019) Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm per square foot or less when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 10l/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of Section 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather stripped.* § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services BHGS . § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of Section 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 i and be labeled er 10-113 when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or § 150.0(c): have a U-factor of 0.071 or less, (R-19 in 2x6 or U-factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U- factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly. Masonry walls must meet Table 150.1-A or B.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor § 150.0(g)1: retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.` Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)l: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.` § 150.0(e)3: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.` Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)4: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)4. § 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU per hour (2 kW) must have isolation valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, § 150.0(h)l: Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. 0 2019 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water Piping, Solar Water -heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum § 150.00)2A: insulation wall thickness of 1 inch or a minimum insulation R-value of 7.7: the first 5 feet of cold water pipes from the storage tank; all hot water piping with a nominal diameter equal to or greater than 3/4 inch and less than 1 inch; all hot water piping with a nominal diameter less than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks, buried below grade, and from the heating source to kitchen fixtures.* § 150.00)3: Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non -crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of § 150.0(n)1: the following: A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater without obstruction. Both ends of the unused conductor must be labeled with the word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit and labeled with the words "Future 240V Use"; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with California Mechanical Code (CMC) Section 604.0. If a contractor installs the insulation, the contractor must certify to the customer in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must meet the requirements of the CMC Section 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed § 150.0(m)1: and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed § 150.0(m)9: to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)11 and Reference Residential Appendix RA3. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or § 150.0(m)12: equivalent filters. Filters for space conditioning systems must have a 2 inch depth or can be 1 inch if sized per Equation 150.0-A. Pressure drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.* Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be >_ 350 CFM § 150.0(m)13: per ton of nominal cooling capacity, and an air -handling unit fan efficacy:5 0.45 watts per CFM for gas furnace air handlers and <_ 0.58 wafts per CFM for all others. Small duct high velocity systems must provide an airflow >_ 250 CFM per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.* 0 2019 Low -Rise Residential Mandatory Measures Summary Requirements for Ventilation and Indoor Air Quality: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation § 150.0(o)1: and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with § 150.0(o)1 C: other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C. Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in § 150.0(o)1 E: accordance with Equation 150.0-13 and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced system is not used, all units in the building must use the same system type and the dwelling -unit envelope leakage must be:5 0.3 CFM at 50 Pa (0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8. Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide § 150.0(o)1 F: ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be within 20% of the unit with the lowest airflow rate as it relates to the individual unit's minimum required airflow rate needed for compliance. § 150.0(o)1 G: Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2. § 150.0(o)2: Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential Appendix RA3.7. Kitchen range hoods must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9.. Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. § 150.0(k)1 D: Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be § 150.0(k)1 E: controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0 k .' § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB.' § 150.0(k)1 H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to § 150.0(k)1 I: comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems! § 150.0(k)2C: Interior Switches and Controls. Lighting must have readily accessible wall -mounted controls that allow the lighting to be manually turned ON and OFF.* § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. 2019 Low -Rise Residential Mandatory Measures Summary Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it: § 150.0(k)2G: provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.0 e ; and meets all other requirements in § 150.0(k)2. § 150.0(k)2H: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by an occupant sensor or a vacancy sensor providing automatic -off functionality. If an occupant sensor is installed, it must be initially configured to manual -on operation using the manual control required under Section 150.0(k)2C. § 150.0(k)2J: Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.` § 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling -installed lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either 150.0 k 3Aii(photocell and either a motion sensor or automatic time switch control or § 150.0 k 3Aiii astronomical time clock), or an EMCS. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances, § 150.0(k)3B: balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either Section 150.0 k 3A or with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by Section 150.0(k)3B or Section 150.0(k)3D must comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1,130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be comply with Table 150.0-A and be controlled by an occupant sensor. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in § 150.0(k)6B: that building must: i. Comply with the applicable requirements in Sections 110.9,130.0,130.1,140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed must comply with the requirements of § 110.1 0b through § 110.10 e . § 110.10(a)2: Low-rise Multifamily Buildings. Low-rise multi -family buildings that do not have a photovoltaic system installed must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with § 110.10(b)1: roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone requirement is applicable to the entire building, including mixed occupancy.* § 110.10(b)2: Azimuth. All sections of the solar zone located on steep -sloped roofs must be oriented between 90 degrees and 300 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a § 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family residences and central water -heating systems, a pathway reserved for routing plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.1 0c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 25 Date 3/19/2020 System Name AC-1 - Floor Area 897 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 723 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 60,000 14,002 304 223 9,012 Total Output (Btuh) 60,000 0 Output (Btuh/sqft) 66.9 808 345 Cooling System 0 0 Output per System 36,000 0 0 0 0 Total Output (Btuh) 36,000 1,489 304 -1,489 Total Output (Tons) 3•0 808 345 Total Output Btuh/sgft 40.1 Total Output s ft/Ton 299.0 1 17,108 8,213 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 3 TON 16/13/9.5 - SEER/EER/HSPF 27,454 2,881 37,474 Airflow cfm/sgft 1.34 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 27,454 2,881 37,474 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air -4 r- 0 cfm 68 OF 68 OF 105 OF 106 OF E -Il I I I Heating Coil Supply Fan 1,200 cfm 106 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62°F 55/54°F 56/54°F Cooling Coil Supply Fan 57 / 55 OF 1,200 cfm--W 46.3% Fkoom 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 25 Date 3/19/2020 System Name AC-2 - Floor Area 1,187 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 581 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 12,925 403 398 8,370 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 32•9 746 320 Cooling System 0 0 Output per System 36,000 0 0 0 0 Total Output (Btuh) 36,000 1,489 403 -1,489 Total Output (Tons) 3.0 746 320 Total Output (Btuh/sqft) 30.3 Total Output (sqf /Ton) 395.7 15,906 7,521 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 3 TON 16/13/9.5 29,677 0 24,358 Airflow (cfm/sgft) 1.01 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 29,677 0 24,358 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 IF Outside Air -4 r- cfm 68 OF go 68 OF 88 OF E0 v I I 1 Heating Coil Supply Fan 1,200 cfm 11 88 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 60 IF 76/60OF 52/51 OF 54/52OF 0' Cooling Coil Supply Fan 54 / 52 OF 1,200 cfm 41.7% ROOM 75 / 60 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 25 Date 3/19/2020 System Name AC-3 - Floor Area 1,856 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,008 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 22,861 630 370 16,680 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 21.0 1,320 638 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output (Btuh) 60,000 1,489 630 -1,489 Total Output (Tons) 5.0 1,320 638 Total Output Btuh/sgft 32.3 Total Output s ft/Ton 371.2 1 26,989 16,466 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 5 TON 16/13/9.5 49,475 0 24,358 Airflow cfm/sgft 1.08 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 49,475 0 24,358 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air -4 r- 0 cfm 68 OF 68 OF 110 OF 111 OF fir E Heating Coil Supply Fan 2,000 cfm 110 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76/60°F 76/60°F 52/51 OF 53/51 OF Cooling Coil Supply Fan 54 / 52 OF 2,000 cfm 41.7% ROOM 75/60°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 25 Date 3/19/2020 System Name AC-4 - Floor Area 562 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 356 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 39,000 7,743 191 195 6,201 Total Output (Btuh) 39,000 0 Output (Btuh/sqft) 69•4 447 237 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output (Btuh) 24,000 1,489 191 -1,489 Total Output (Tons) 2.0 447 237 Total Output Btuh/sgft 42.7 Total Output s ft/Ton 281.0 1 10,126 5,186 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 2TON 16/13/9.5 19,763 0 24,358 Airflow cfm/sgft 1.42 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 19,763 0 24,358 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 68 OF 68 OF 96 OF ^ 98 OF I - a110 r - - Heating Coil Supply Fan 800 cfm 98 OF IROIOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 60 IF 76/60OF 52/51 OF 54/52OF Cooling Coil Supply Fan 55 / 52 OF 800 cfm 41.5% ROOM Iff 75 / 60 OF