Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Andalusia TR 31681 BCPR2020-0022 (Plans 301, 302, 303, 401, & 402)
Project Details PROJECT NUMBER Cit of La Quinta BCPR2020-0022 Description: ANDALUSIA /TRACT CONSTRUCTION PLANS 300 & 400 Status: APPROVED SERIES(SFDx5) Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB) Status Date: Subtype: TRACT RESIDENTIAL Applied: 12/14/2020 Address: 59000 MADISON ST Approved: 2/17/2021 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: Expired: Details: ANDALUSIA / TRACT CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. PLAN 301: 3,326 S.F. PLAN 302: 3.694 S.F. PLAN 303: 4.032 S.F. PLAN 401: 4,426 S.F. PLAN 402: REVISION 1 - FIELD CHANGES FOR PLANS 301, 302 & 303. PLAN 301: DOOR AND WINDOW CHANGES, REVISE KITCHEN APPLIANCE LAYOUT, RECESS SHOWER FLOORS AND UPDATE TOTAL CONDITIONED FLOOR AREA. [NEW CONDITIONED LIVABLE AREA OF 3,333SF]. PLAN 302: DOOR AND WINDOW CHANGES, RECESS SHOWER FLOORS & INTERIOR ARCHITECTURAL CHANGES PLAN 303: DOOR CHANGE, RECESS SHOWER FLOORS & INTERIOR ARCHITECTURAL CHANGE DAYS REVIEWS ACTIONS INSPECTIONS CONDITIONS 0 CASE OPEN OPEN COMPLETED CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE AARON HICKSON 12/15/2020 12/15/2020 SEN COMPLETE TO INTERWEST AS THEY HAVE DONE PAST REVIEWS Printed: Wednesday, December 20, 2023 10:53:45 AM 1 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER �yCity �'of La uinta BCPR2020-0022 pimp r`7 `/�'C Ot T\4F. 1ST PC COMPLETE/READY JAKE FUSON 1/15/2021 1/15/2021 NOTIFIED NOLAN SPARKS OF 1ST REVIEW COMMENTS, SENT FOR PICK UP CORRECTION LIST VIA EMAIL. 2ND PC SUBMITTAL JAKE FUSON 2/1/2021 2/1/2021 RECEIVED NOTIFIED NOLAN SPARKS OF THE 2ND REVIEW COMMENTS, EMAIL JAKE FUSON 2/11/2021 2/11/2021 LET HIM KNOW I WILL EXPEDITE THE REVIEW AND APPROVAL UPON RETURN OF THE PLANS WITH THE MINOR CORRECTIONS INCORPORATED. EMAIL JAKE FUSON 2/17/2021 2/17/2021 NOTIFIED NOLAN SPARKS THAT PLANS ARE APPROVED AND FEE IS READY FOR PAYMENT. EMAIL JAKE FUSON 3/23/2022 3/23/2022 NOTIFIED APPLICANT OF REVISION 1 - 1ST REVIEW COMMENTS. 2ND PC SUBMITTAL JAKE FUSON 3/29/2022 3/29/2022 REVISION 1 - 2ND SUBMITTAL RECEIVED VIA ETRAKIT. RECEIVED EMAIL JAKE FUSON 5/5/2022 5/5/2022 NOTIFIED NOLAN SPARKS AND PEKAREK ARCHITECTS OF REVISION 1 - 2ND REVIEW COMMENTS. EMAIL JAKE FUSON 5/11/2022 5/11/2022 NOTIFIED NOLAN SPARKS AND PAKEREK ARCHITECTS THAT REVISION 1 IS APPROVED AND READY FOR FEE PAYMENT. • NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT NOLAN SPARKS / NATIONAL 81570 Carboneras La Quinta CA 92253 (760)408-0106 nsparks@andalusiacc.c MORTGAGE & LAND COMPANY om ARCHITECT Pekarek Architects San Juan CA 92253 (760)408-0106 jhales@pekarekarch.co Capistrano m DEVELOPER Sunrise LQ LLC 81570 Carboneras La Quinta CA 92253 (760)408-0106 nsparks@andalusiacc.c om ENGINEER Gouvis Engineering Newport Beach CA 92253 (760)408-0106 mhoushmand@gouvisg roup.com Printed: Wednesday, December 20, 2023 10:53:45 AM 2 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL OWNER Sunrise LQ, LLC 81570 Carboneras PALM DESERT CA 92211 (760)408-0106 nsparks@andalusiacc.c om PRIMARY Nolan Sparks 81570 Carboneras La Quinta CA 92253 (760)408-0106 nsparks@andalusiacc.c CONTACT om CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY 101-0000-42600 ($644.00) ($644.00) 2/17/21 OFFSET OFFSET JFU 101-0000-42600 ($437.50) ($437.50) 2/17/21 OFFSET OFFSET JFU 101-0000-42600 ($176.50) ($176.50) 2/17/21 OFFSET OFFSET JFU NOLAN SPARKS / HOURLY CHARGE - CITY 101-0000-42600 4 $644.00 $644.00 2/17/21 DEPOSIT DEPOSIT NATIONAL JFU BUILDING STAFF MORTGAGE & LAND COMPANY HOURLY CHARGE - CITY 101-0000-42600 2 $322.00 $322.00 5/16/22 WEB11759 637199714 CREDIT 288130 ECON BUILDING STAFF 63 HOURLY CHARGE - NOLAN SPARKS / INTERWEST 101-0000-42600 3.5 $437.50 $437.50 2/17/21 DEPOSIT DEPOSIT NATIONAL JFU STRUCTURAL PLAN MORTGAGE & LAND REVIEW COMPANY HOURLY CHARGE - NOLAN SPARKS / INTERWEST 101-0000-42600 9 $176.50 $176.50 2/17/21 DEPOSIT DEPOSIT NATIONAL JFU STRUCTURAL PLAN MORTGAGE & LAND REVIEW COMPANY HOURLY CHARGE - NOLAN SPARKS / INTERWEST 101-0000-42600 0 $948.50 $948.50 2/18/21 WEB7438 10951D CREDIT NATIONAL ECON STRUCTURAL PLAN MORTGAGE & LAND REVIEW COMPANY Total Paid for BUILDING STAFF - PER HOUR: $1,270.50 $1,270.50 Printed: Wednesday, December 20, 2023 10:53:45 AM 3 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BUILDING TRACT NOLAN SPARKS / RESIDENTIAL 101-0000-42600 1 $1,500.00 $1,500.00 12/14/20 WEB6975 75418D CREDIT NATIONAL ECON CONSTRUCTION PLAN MORTGAGE & LAND DEPOSIT COMPANY Total Paid for BUILDING TRACT RESIDENTIAL $1,500.00 $1,500.00 CONSTRUCTION PLAN DEPOSIT: 101-0000-42600 ($242.00) ($242.00) 12/29/20 OFFSET OFFSET KHET FIRE NEW RESIDENTIAL 101-0000-42420 0 $242.00 $242.00 12/29/20 DEPOSIT DEPOSIT KHET PC Total Paid for FIRE FEES: $0.00 $0.00 NOLAN SPARKS / RECORDS MANAGEMENT FEE - 101-0000-42416 0 $21.00 $21.00 12/14/20 WEB6975 75418D CREDIT NATIONAL ECON MORTGAGE & LAND MAJOR COMPANY Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 NOLAN SPARKS / TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 12/14/20 WEB6975 75418D CREDIT NATIONAL ECON ENHANCEMENT FEE MORTGAGE & LAND COMPANY Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 NOLAN SPARKS / NEW CONSTRUCTION - 101-0000-42400 0 $644.00 $644.00 1/3/21 WEB7064 98940D CREDIT NATIONAL ECON 5+ RESIDENTIAL UNITS MORTGAGE & LAND COMPANY Total Paid for ZONING CLEARANCE - PLANNING PLAN $644.00 $644.00 CHECK: 1 INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED I RESULTA REMARKS DATE I NOTES Printed: Wednesday, December 20, 2023 10:53:45 AM 4 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE REVISION 1 - FIELD REVISIONS FOR PLANS 301, 302 & 303. 1ST BLDG (1WK) JAKE FUSON 2/8/2022 2/15/2022 3/23/2022 PENDING DOCUMENTS REVISION 1 PROVIDE WRITTEN NARRATIVE OF CHANGES AND ONLY INCLUDE THE SHEETS THAT CHANGED. 1ST BLDG INTERWEST 12/14/2020 1/8/2021 1/11/2021 REVISIONS REQUIRED COMPLETE (3WK) 1ST BLDG NS (3WK) JAKE FUSON 12/14/2020 1/8/2021 1/15/2021 REVISIONS REQUIRED SEE 1ST REVIEW COMPLETE CORRECTION LIST. FIRE GENERAL CONDITIONS OF APPROVAL Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their background shall be displayed on the structure and viewable from the roadway or 1ST FIRE (2WK) KOHL 12/14/2020 12/30/2020 12/29/2020 READY FOR APPROVAL COA IN NOTES Posted at the driveway entrance and maintained HETRICK visible. A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed Contractor (C-16) shall submit plans and details for review and approval prior to Rough Inspections. 1ST PERMIT PERMIT TECH 12/14/2020 12/15/2020 12/15/2020 COMPLETE TECHNICIAN (1DAY) BUCKET 1ST PLANNING CARLOS 12/14/2020 12/30/2020 12/30/2020 READY FOR APPROVAL (2WK) FLORES PRIOR TO BUILDING PERMIT ISSUANCE, 1ST PUBLIC WORKS AMY YU 12/14/2020 12/30/2020 12/15/2020 APPROVED- APPROVED PRECISE GRADING PLANS NEED TO (2WK) CONDITIONS REFLECT PLAN TYPE AND FOOTPRINT AND PAD CERTS ARE REQUIRED. Printed: Wednesday, December 20, 2023 10:53:45 AM 5 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 -THE REQUIRED PV SYSTEM SIZES WERE NOT ADDED TO THE COVER SHEET NOTES FOR EACH PLAN SET 2ND BLDG (1WK) JAKE FUSON 2/1/2021 2/8/2021 2/11/2021 REVISIONS REQUIRED -R-20 IS SHOWN AT THE HIGH WALLS, R-21 MIN. REQUIRED PER ENERGY REPORT -SELF-CLOSING & SELF -LATCHING NOTE NOT UPDATED ON REVERSE FLOOR PLAN OF PLAN 301 (SHEET 301-4) PROVIDE UPDATED ENERGY REPORTS FOR THE 2ND BLDG (1WK) JAKE FUSON 3/29/2022 4/5/2022 5/5/2022 REVISIONS REQUIRED INCREASES IN GLAZED OPENINGS ON ALL PLANS AND NEW CONDITIONED FLOOR AREA OF PLAN 301. 2ND BLDG INTERWEST 2/1/2021 2/8/2021 2/9/2021 APPROVED COMPLETE (2WK) 3RD BLDG (1WK) JAKE FUSON 2/16/2021 2/23/2021 2/16/2021 APPROVED REVISION 1 - FIELD CHANGES FOR PLANS 301, 302 & 303. PLAN 301: DOOR AND WINDOW CHANGES, REVISE KITCHEN APPLIANCE LAYOUT, RECESS SHOWER FLOORS AND UPDATE TOTAL CONDITIONED FLOOR AREA. [NEW CONDITIONED 3RD BLDG (1WK) JAKE FUSON 5/9/2022 5/10/2022 5/11/2022 APPROVED REVISION 1 LIVABLE AREA OF 3,333SF]. PLAN 302: DOOR AND WINDOW CHANGES, RECESS SHOWER FLOORS & INTERIOR ARCHITECTURAL CHANGES PLAN 303: DOOR CHANGE, RECESS SHOWER FLOORS & INTERIOR ARCHITECTURAL CHANGE BOND INFORMATION Printed: Wednesday, December 20, 2023 10:53:45 AM 6 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/26/2021 ARMANDO MAGALLON BCPR2020-0022 - PLAN BCPR2020-0022 - PLAN 0 303 TAKEOFF SHEET.xlsx 303 TAKEOFF SHEET.xlsx DOC 4/26/2021 ARMANDO MAGALLON BCPR2020-0022 - PLAN BCPR2020-0022 - PLAN 0 401 TAKEOFF SHEET.xlsx 401 TAKEOFF SHEET.xlsx DOC 4/26/2021 ARMANDO MAGALLON BCPR2020-0022 - PLAN BCPR2020-0022 - PLAN 0 402 TAKEOFF SHEET.xlsx 402 TAKEOFF SHEET.xlsx DOC 4/26/2021 ARMANDO MAGALLON BCPR2020-0022 - PLAN BCPR2020-0022 - PLAN 0 301 TAKEOFF SHEET.xlsx 301 TAKEOFF SHEET.xlsx DOC 4/26/2021 ARMANDO MAGALLON BCPR2020-0022 - PLAN BCPR2020-0022 - PLAN 0 302 TAKEOFF SHEET.xlsx 302 TAKEOFF SHEET.xlsx 1ST SUBMITTAL 302 DOC 12/14/2020 EtrakitContractor STRUCTURAL COVER plan 302 Str Calc Cover 1 Sheet.pdf SHEET DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 302 plan 302 Str Calcs.pdf 1 STUCTURAL CALCS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 302 Plan 302 T24s.pdf 1 ENERGY DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 302 Plan 302_1.pdf 1 PLANS 1ST SUBMITTAL 303 plan 303 Str Calc Cover DOC 12/14/2020 EtrakitContractor STRUCTURAL COVER 1 Sheet.pdf SHEET DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 303 plan 303 Str Calcs.pdf 1 STUCTURAL CALCS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 303 Plan 303 T24s.pdf 1 ENERGY DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 303 Plan 303_1.pdf 1 PLANS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL Geotech Update Feb 1 GEOTECHNICAL 2020.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 7 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 401 STR Plan 401 Str Calcs Cover 1 COVER SHEET Sheet.pdf DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 401 plan 401 Str Calcs_1.pdf 1 STRUCTURAL CALCS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 401 Plan 401 T24s.pdf 1 ENERGY DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 401 Plan 401_2.pdf 1 PLANS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 402 STR Plan 402 Str Calcs Cover 1 COVER SHEET Sheet.pdf DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 402 plan 402 Str Calcs_1.pdf 1 STRUCTURAL CALCS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 402ENERGY Plan 402 T24s.pdf 1 DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 402 Plan 402_2.pdf 1 PLANS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 301 STR Plan 301 Str Calc Cover 1 COVER SHEET Sheet.pdf DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 301STRUCTURAL Plan 301 Str Calcs.pdf 1 CALCS DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 301ENERGY Plan 301 Title 24s.pdf 1 DOC 12/14/2020 EtrakitContractor 1ST SUBMITTAL 301 301_1.pdf 1 PLANSPlan 20-12-625 Plan 301 DOC 1/3/2021 EtrakitContractor Plan 301 Geotech Fdn (Foundation Plan 1 Plan Approval Letter Review).pdf 20-12-626 Plan 302 DOC 1/3/2021 EtrakitContractor Plan 302 Geotech Fdn (Foundation Plan 1 Plan Approval Letter Review).pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 8 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 20-12-627 Plan 303 DOC 1/3/2021 EtrakitContractor Plan 303 Geotech Fdn (Foundation Plan 1 Plan Approval Letter Review).pdf 20-12-628 Plan 401 DOC 1/3/2021 EtrakitContractor Plan 401 Geotech Fdn (Foundation Plan 1 Plan Approval Letter Review).pdf 20-12-629 Plan 402 DOC 1/3/2021 EtrakitContractor Plan 402 Geotech Fdn (Foundation Plan 1 Plan Approval Letter Review).pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN Plan 301 Complete 1 301 PLAN SET Set.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN Plan 302 Complete 1 302 PLAN SET Set.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN Plan 303 complete 1 303 PLAN SET Set.pdf 2ND SUBMITTAL - PLANS 301, 302 & 303 Pekarek Plan Check DOC 1/29/2021 EtrakitContractor 1 ARCHITECTURAL Reply.pdf RESPONSES 2ND SUBMITTAL - DOC 1/29/2021 EtrakitContractor PLANS 301, 302 & 303 Gouvis Response 1 STRUCTURAL Letter.pdf RESPONSES RESPONDED LIST - MECHANICAL, 2ND SUBMITTAL - PLUMBING and ENERGY DOC 1/29/2021 EtrakitContractor PLANS 301, 302 & 303 REPORT ONLY -- 1 MEP RESPONSES BCPR2020-0022 - 1ST REVIEW - COMPLETE CORRECTION LIST.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL -PLAN 033 - ANDALUSIA - 1 301 ENERGY REPORT PLAN 301.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 9 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN 2R - 034 - ANDALUSIA - 1 302 ENERGY REPORT PLAN 302.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN 211 - 035 - ANDALUSIA - 1 303 ENERGY REPORT PLAN 303.pdf Plan 301 Stud Column DOC 1/29/2021 EtrakitContractor Calcs (DESIGNER MUST 65431 Plan 301 Stud 1 Column Report.pdf ADD TO SET) DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN Plan 401 Complete 1 401 PLAN SET Set.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL - PLAN Plan 402 Complete 1 402 PLAN SET Set.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL- PLAN 1R - 049 -ANDALUSIA - 1 401 ENERGY REPORT PLAN 401.pdf DOC 1/29/2021 EtrakitContractor 2ND SUBMITTAL- PLAN 1R - 050 - ANDALUSIA - 1 402 ENERGY REPORT PLAN 402.pdf 2ND SUBMITTAL - DOC 1/29/2021 EtrakitContractor PLANS 401 & 402 Govis Response 1 STRUCTURAL Letter.pdf RESPONSES 2ND SUBMITTAL - PLAN 401 & 402 Pekarek Plan Check DOC 1/29/2021 EtrakitContractor 1 ARCHITECTURAL Reply_1.pdf RESPONSES RESPONDED LIST - MECHANICAL, 2ND SUBMITTAL - PLUMBING and ENERGY DOC 1/29/2021 EtrakitContractor PLANS 401 & 402 MEP REPORT ONLY -- 1 RESPONSES BCPR2020-0022 - 1ST REVIEW - COMPLETE CORRECTION LIST_1.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 10 of 17 CENTRALSQUARE N A. Project Details PROJECT NUMBER -� City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 2ND SUBMITTAL - PLAN Andalusia Club Villas DOC 1/29/2021 EtrakitContractor 301 TRUSS Plan 301 Submittal Set 1 CALCULATIONS 01-06-2021.pdf 2ND SUBMITTAL - PLAN Andalusia Club Villas DOC 1/29/2021 EtrakitContractor 302 TRUSS Plan 302 Submittal Set 1 CALCULATIONS 01-06-2021.pdf 2ND SUBMITTAL - PLAN Andalusia Club Villas DOC 1/29/2021 EtrakitContractor 303 TRUSS Plan 303 Submittal Set 1 CALCULATIONS 01-06-2021.pdf 2ND SUBMITTAL - PLAN Andalusia Club Villas DOC 1/29/2021 EtrakitContractor 401 TRUSS Plan 401 Submittal Set 1 CALCULATIONS 01-06-2021.pdf 2ND SUBMITTAL - PLAN Andalusia Club Villas DOC 1/29/2021 EtrakitContractor 402 TRUSS Plan 402 Submittal Set 1 CALCULATIONS 01-06-2021.pdf DOC 2/15/2021 EtrakitContractor 3RD SUBMITTAL - PLAN Plan 301 Complete 1 301 PLAN SET Set_1.pdf DOC 2/15/2021 EtrakitContractor 3RD SUBMITTAL - PLAN Plan 302 Complete 1 302 PLAN SET Set_1.pdf DOC 2/15/2021 EtrakitContractor 3RD SUBMITTAL - PLAN Plan 303 Complete 1 303 PLAN SET Set_1.pdf DOC 2/15/2021 EtrakitContractor 3RD SUBMITTAL - PLAN Plan 401 Complete 1 401 PLAN SET Set_1.pdf DOC 2/15/2021 EtrakitContractor 3RD SUBMITTAL - PLAN Plan 402 Complete 1 402 PLAN SET Set_1.pdf DOC 2/7/2022 Etrakit Contractor REVISION 1-1ST Plan 301 Compiled Set 1 1 SUBMITTAL - PLAN 301 -26-22.pdf DOC 2/7/2022 Etrakit Contractor REVISION 1-1ST Plan 302 Compiled Set 1 1 SUBMITTAL - PLAN 302 -26-22.pdf DOC 2/7/2022 Etrakit Contractor REVISION 1-1ST Plan 303 Compiled Set 1 1 SUBMITTAL - PLAN 303 -26-22.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 11 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED REVISION 1 - 2ND DOC 3/28/2022 Etrakit Contractor SUBMITTAL PLANS - Plan 1 Compiled Set.pdf 1 PLAN 301 REVISION 1 - 2ND DOC 3/28/2022 Etrakit Contractor SUBMITTAL PLANS - Plan 2 Compiled Set.pdf 1 PLAN 302 REVISION 1 - 2ND DOC 3/28/2022 Etrakit Contractor SUBMITTAL PLANS - Plan 3 Compiled Set.pdf 1 PLAN 303 REVISION 1 - 2ND DOC 3/28/2022 Etrakit Contractor SUBMITTAL NARRATIVE Pekarek Response 1 Letter.pdf OF CHANGES REVISION 1 - 2ND SUBMITTAL DOC 3/28/2022 Etrakit Contractor STRUCTURAL 65431 Plan 303 Revised 1 S.W (1).pdf CALCULATIONS (PLAN 303) REVISION 1 - 2ND SUBMITTAL DOC 3/29/2022 Etrakit Contractor STRUCTURAL 65431 Plan 301 Revised 1 S.W (1).pdf CALCULATIONS (PLAN 301) 01 - GLS - MEP REVISION 1 - 3RD DOC 5/9/2022 Etrakit Contractor SUBMITTAL MEP MULTIFILE - 411 - 000 - 1 DRAWINGS (PLAN 301) PLAN 301 - 59000 MADISON.pdf 01 - GLS - MEP REVISION 1 - 3RD DOC 5/9/2022 Etrakit Contractor SUBMITTAL MEP - MULTIFILE - 511 - 000pLAN 1 303 - 59000 DRAWINGS (PLAN 303) MADISON.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 12 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 01 - GLS - MEP REVISION 1 - 3RD DOC 5/9/2022 Etrakit Contractor SUBMITTAL MEP - MULTIFILE - 511- 000pLAN 1 DRAWINGS (PLAN 302) 302 - 59000 MADISON.pdf 02 - GLS - ENERGY REVISION 1 - 311D DOC 5/9/2022 Etrakit Contractor SUBMITTAL ENERGY REPORT - 211 - 033 - 1 REPORT (PLAN 301) ANDALUSIA - PLAN 301- ver 8.2.pdf 02 - GLS - ENERGY REVISION 1 - 3RD DOC 5/9/2022 Etrakit Contractor SUBMITTAL ENERGY REPORT - 411 - VER 8.2 - 1 035 - ANDALUSIA - PLAN REPORT (PLAN 303) 303.pdf 02 - GLS - ENERGY REVISION 1 - 3RD DOC 5/9/2022 Etrakit Contractor SUBMITTAL ENERGY REPORT - 411 - VER 8.2 - 1 REPORT (PLAN 302) 034 - ANDALUSIA - PLAN 302.pdf Invoice 65654- City of La DOC 1/11/2021 INTERWEST 1ST REVIEW - Quinta (LAQ20-0015) - 1 0 INTERWEST INVOICE -1-20.pdf DOC 1/11/2021 INTERWEST 1ST REVIEW - LAQ20-0015 (BCPR2020- 0 INTERWEST COMMENTS 0022) PC1.docx 2ND REVIEW - LAQ20-0015 (BCPR2020- DOC 2/9/2021 INTERWEST INTERWEST 0 0022) PCF.docx TRANSMITTAL DOC 2/9/2021 INTERWEST 2ND REVIEW - La Quinta - LAQ20-0015 0 INTERWEST INVOICE - 66389.pdf 1ST REVIEW - BCPR2020-0022 - 1ST DOC 1/15/2021 1AKE FUSON COMPLETE CORRECTION REVIEW - COMPLETE 1 LIST CORRECTION LIST.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 13 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON FOUNDATION PLAN FOUNDATION PLAN 1 REVIEW LETTER -PLAN REVIEW LETTER - PLAN 401 401.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON FOUNDATION PLAN FOUNDATION PLAN 1 REVIEW LETTER -PLAN REVIEW LETTER - PLAN 301 301.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON FOUNDATION PLAN FOUNDATION PLAN 1 REVIEW LETTER -PLAN REVIEW LETTER - PLAN 303 303 (1).pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON FOUNDATION PLAN FOUNDATION PLAN 1 REVIEW LETTER -PLAN REVIEW LETTER - PLAN 402 402.pdf BCPR2020-0022 - APPROVED TRUSS DOC 2/16/2021 JAKE FUSON CALCULATIONS - PLAN APPROVED TRUSS 1 CALCULATIONS - PLAN 301 301.pdf BCPR2020-0022 - APPROVED TRUSS DOC 2/16/2021 JAKE FUSON CALCULATIONS - PLAN APPROVED TRUSS 1 CALCULATIONS - PLAN 302 302.pdf BCPR2020-0022- APPROVED TRUSS DOC 2/16/2021 JAKE FUSON CALCULATIONS - PLAN APPROVED TRUSS 1 CALCULATIONS - PLAN 303 303.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 14 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2020-0022 - APPROVED TRUSS DOC 2/16/2021 JAKE FUSON CALCULATIONS - PLAN APPROVED TRUSS 1 CALCULATIONS - PLAN 401 401.pdf BCPR2020-0022 - APPROVED TRUSS DOC 2/16/2021 JAKE FUSON CALCULATIONS - PLAN APPROVED TRUSS 1 CALCULATIONS - PLAN 402 402.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON FOUNDATION PLAN FOUNDATION PLAN 1 REVIEW LETTER -PLAN REVIEW LETTER - PLAN 302 302.pdf BCPR2020-0022 - DOC 2/16/2021 JAKE FUSON APPROVED APPROVED 1 GEOTECHNICAL UPDATE GEOTECHNICAL UPDATE.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS -PLAN CALCULATIONS - PLAN 301 301.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS -PLAN CALCULATIONS - PLAN 302 302.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS -PLAN CALCULATIONS - PLAN 303 303.pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 15 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS -PLAN CALCULATIONS - PLAN 401 401.pdf BCPR2020-0022- APPROVED APPROVED DOC 2/16/2021 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS -PLAN CALCULATIONS - PLAN 402 402.pdf BCPR2020-0022- DOC 2/17/2021 JAKE FUSON APPROVED PLANS- APPROVED PLANS - 1 PLAN 301 PLAN 301.pdf BCPR2020-0022- DOC 2/17/2021 JAKE FUSON APPROVED PLANS- APPROVED PLANS - 1 PLAN 302 PLAN 302.pdf BCPR2020-0022- DOC 2/17/2021 JAKE FUSON APPROVED PLANS- APPROVED PLANS - 1 PLAN 303 PLAN 303.pdf BCPR2020-0022- DOC 2/17/2021 JAKE FUSON APPROVED PLANS- APPROVED PLANS - 1 PLAN 401 PLAN 401.pdf BCPR2020-0022- DOC 2/17/2021 JAKE FUSON APPROVED PLANS- APPROVED PLANS - 1 PLAN 402 PLAN 402.pdf BCPR2020-0022 - REVISION 1 - PLAN 301 - DOC 5/11/2022 JAKE FUSON ENERGY REPORT REVISION 1 - PLAN 301 - 1 ENERGY REPORT (APPROVED) (APPROVED).pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 16 of 17 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2020-0022 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2020-0022 - REVISION 1 - PLAN 301 - REVISION 1 - PLAN 301 - DOC 5/11/2022 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS CALCULATIONS (APPROVED) (APPROVED).pdf BCPR2020-0022 - REVISION 1 - PLAN 302 - DOC 5/11/2022 JAKE FUSON ENERGY REPORT REVISION 1 - PLAN 302 - 1 (APPROVED) ENERGY REPORT (APPROVED).pdf BCPR2020-0022 - REVISION 1 - PLAN 303 - DOC 5/11/2022 JAKE FUSON ENERGY REPORT REVISION 1 - PLAN 303 - 1 (APPROVED) ENERGY REPORT (APPROVED).pdf BCPR2020-0022 - REVISION 1 - PLAN 303 - REVISION 1 - PLAN 303 - DOC 5/11/2022 JAKE FUSON STRUCTURAL STRUCTURAL 1 CALCULATIONS CALCULATIONS (APPROVED) (APPROVED).pdf BCPR2020-0022 - DOC 5/11/2022 JAKE FUSON REVISION 1 -PLAN 301 - REVISION 1 - PLAN 301 - 1 PLANS (APPROVED) PLANS (APPROVED).pdf BCPR2020-0022 - DOC 5/11/2022 JAKE FUSON REVISION 1 -PLAN 302 - REVISION 1 - PLAN 302 - 1 PLANS (APPROVED) PLANS (APPROVED).pdf BCPR2020-0022 - DOC 5/11/2022 JAKE FUSON REVISION 1 -PLAN 303 - REVISION 1 - PLAN 303 - 1 PLANS (APPROVED) PLANS (APPROVED).pdf Printed: Wednesday, December 20, 2023 10:53:45 AM 17 of 17 CENTRALSQUARE Invoice No.: 65654 rw INTERWEST Remit to: Interwest Consulting Group PO BOX 18330 BOULDER, CO 80308 Direct questions to: Ashley Avery aavery@interwestgrp.com Invoice Date: 1/11/2021 Interwest Job No.: LAQ20-0015 Residential - Adalusia Development - BCPR2020-0022 59000 Madison Professional Services for the Period January 1, 2020 through January 11, 2021 Bill to: City of La Quinta Attention Danny Castro, Design & Development Director 78495 Calle Tampico La Quinta, CA 92253 Project Person Title Week End Hours Total Invoice Total $1,125.00 Rate Total Bryan Montes Plan Check Engineer 1/10/2021 5 $125.00 $625.00 Sandra Schmitz Plan Check Engineer 1/10/2021 4 $125.00 $500.00 $11125.00 Invoice No.: 66389 rw INTERWEST Remit to: Interwest Consulting Group PO BOX 18330 BOULDER, CO 80308 Direct questions to: Ashley Avery aavery@interwestgrp.com Invoice Date: 2/9/2021 Interwest Job No.: LAQ20-0015 Residential - Adalusia Development - BCPR2020-0022 59000 Madison Professional Services for the Period February 1 through February 9 2021 Bill to: City of La Quinta Attention Danny Castro, Design & Development Director 78495 Calle Tampico La Quinta, CA 92253 Project Person Title Week End Hours Total Invoice Total $437.50 Rate Total Sandra Schmitz Plan Check Engineer 2/7/2021 1.5 $125.00 $187.50 Bryan Montes Plan Check Engineer 2/14/2021 2 $125.00 $250.00 $437.50 BUILDING ENERGY ANALYSIS REPORT I PROJECT: PLAN # 301 59000 MADISON CLUB VILLAS ANDALUSIA C.C. LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 760 340.3528 Report Prepared by: TITLE 24 OF THE DESERT SERVICES INC. title24ofthedesert@gmail.com 760 278.1840, Job Number: 22 - 20 - GLS /036 - 033 - 2R - 040 Date: 5/6/2022 REVISION 1 BCPR2020-0024 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE p,05/11/2022 n, PLAN 301 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 20 Form MF-1 R Mandatory Measures Summary 22 HVAC System Heating and Cooling Loads Summary 26 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 1 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x GENERAL INFORMATION 01 Project Name PLAN 301 ANDALUSIA 02 Run Title Title 24 Analysis 03 Project Location 59000 MADISON CLUB VILLAS ANDALUSIA C.C. 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.31 18 Total Cond. Floor Area (ftZ) 3333 19 Glazing Percentage (%) 26.16% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available? I Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 2 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 46.1 22.7 Proposed Designs North Facing 45.7 22.3 0.4 0.4 East Facing 46 22.6 0.1 0.1 South Facing 43.8 20.3 2.3 2.4 West Facing 45.5 22.1 0.6 0.6 RESULT: 3: COMPLIES Efficiency EDR includes improvements to the building envelope and more efficient equipment Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc. s Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 6.30 kWdc • Proposed PV Capacity Scaling: North (6.30 kWdc) East (6.30 kWdc) South (6.30 kWdc) West (6.30 kWdc) Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 3 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x ENERGY USE SUMMARY Energy Use (kTDWft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.32 3.57 -1.25 -53.9 Space Cooling 90.44 87.06 3.38 3.7 IAQ Ventilation 2.29 2.29 0 0 Water Heating 6.4 7.3 -0.9 -14.1 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 101.45 100.22 1.23 1.2 Space Heating 2.32 4.23 -1.91 -82.3 Space Cooling 90.44 87.3 3.14 3.5 IAQ Ventilation 2.29 2.29 0 0 Water Heating 6.4 7.3 -0.9 -14.1 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 101.45 101.12 0.33 0.3 Space Heating 2.32 3.71 -1.39 -59.9 Space Cooling 90.44 S P R 81.1 9.34 10.3 IAQ Ventilation 2.29 2.29 0 0 Water Heating 6.4 7.3 -0.9 -14.1 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 101.45 94.4 7.05 6.9 Space Heating 2.32 3.47 -1.15 -49.6 Space Cooling 90.44 86.68 3.76 4.2 IAQ Ventilation 2.29 2.29 0 0 Water Heating 6.4 7.3 -0.9 -14.1 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 101.45 99.74 1.71 1.7 Registration Number: 220-P010091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 4 of 17) Input File Name: 211 - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Tilt: (x in Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) 12) N Solar Access N 6.3 NA Standard Fixed none true 150-270 n/a n/a <=7:12 96 100 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins • Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) ,IlkHERS PROVIDER CaICERTS, Inc. Registration Number: Registration Date/Time: HERS Provider: 220-P010091632D-000-000-0000000-0000 2022-05-06 14:54:51 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 5 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Airflow in habitable rooms (SC3.1.4.1.7) • Minimum Airflow according to RA3.3 and SC3.3.3.4.1 • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity • CEC certified low -static VCHP system • Wall -mounted thermostat in zones greater than 150 ft2 (SC3.4.5) • Verified air filter sizing (SC3.1.4.7) i� , Inc. • Verified air filter pressure drop rating H E R S P R O V I D E R HVAC Distribution System Verifications: • Duct leakage testing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8) Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name z Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems PLAN 301 ANDALUSIA 3333 1 4 3 0 1 Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 6 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Z1- 1416 Conditioned AC-1 -1 1416 12 DHW Sys 1 N/A Z2 - 1497 Conditioned AC-2 -2 1497 10 DHW Sys 1 N/A Z3 - 420 Conditioned AC-3 -3 420 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftz) Window and Door Area (ft2) Tilt (deg) N - 504 Z1- 1416 R-21 Wall 0 Front 504 92 90 E - 246 Z1- 1416 R-21 Wall 90 Left 246 60 90 S - 204 Z1- 1416 R-21 Wall 180 Back 204 66 90 W - 468 Z1- 1416 R-21 Wall 270 Right 468 279.981 90 N - 414 Z2 - 1497 R-21 Wall 0 Front 414 66 90 E - 90 Z2 - 1497 R-21 Wall 90 Left 90 16.5 90 S - 762 Z2-1497 R-21 Wall 180 Back 762 124.75 90 W - 197 Z2-1497 R-21 Wall 270 Right 200 72 90 N - 373 Z3 - 420 R-21 Wall 0 Front 373 26 90 E - 182 Z3 - 420 R-21 Wall 90 Left 182 16.5 90 S - 373 Z3 - 420 R-21 Wall 180 Back 373 43.008 90 W - 182 Z3 - 420 R-21 Wall 270 Right 182 57.024 90 TO GARAGE Z3 - 420>>Z1- 1416 R-21 Wall1 n/a n/a 184 0 n/a 1416 Z1- 1416 R-38 n/a n/a 1416 n/a n/a 1497 Z2-1497 R-38 n/a n/a 1497 n/a n/a 420 Z3-420 R-38 n/a n/a 420 n/a n/a Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 7 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Z1- 1416 Attic RoofZ1- 1416 Unventilated 4 0.1 0.85 No No Attic Z2 - 1497 Attic RoofZ2 - 1497 Unventilated 4 0.1 0.85 No No Attic Z3 - 420 Attic RoofZ3 - 420 Unventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading 3070 - 10 Window N - 504 Front 0 3 7 1 21 0.32 NFRC 0.25 NFRC Bug Screen 3070 - 5 Window N - 504 Front 0 1 21 0.28 NFRC 0.22 NFRC Bug Screen 3070 - 5 2 Window N - 504 Front 0 3 7 1 21 0.28 NFRC 0.22 NFRC Bug Screen 3070 - 5 3 Window N - 504 Front 0 1 21 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 15 Window N - 504 Front 0 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 15 2 Window N - 504 Front 0 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 3080 -18 Window E - 246 Left 90 3 8 1 24 0.29 NFRC 0.17 NFRC Bug Screen 6020 - 18 Window E - 246 Left 90 6 2 1 12 0.24 NFRC 0.22 NFRC Bug Screen 46100 - 7 - 2R Window S - 204 Back 180 4.5 10 1 45 0.36 NFRC 0.22 NFRC Bug Screen 3070 - 10 2 Window S - 204 Back 180 3 7 1 21 0.32 NFRC 0.25 NFRC Bug Screen 180100 - 8 - 2R Window W - 468 Right 270 18 10 1 180 0.36 NFRC 0.22 NFRC Bug Screen 11570 - 9 -2R Window W - 468 Right 270 11.5 7 1 99.98 0.29 NFRC 0.2 NFRC Bug Screen 3056 - 3 Window N - 414 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 2 Window N - 414 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 3 Window N - 414 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 4 Window N - 414 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 5 Window E - 90 Left 90 3 5.5 1 16.5 0.27 1 NFRC 0.19 NFRC Bug Screen Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 8 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 3050 - 2 Window S - 762 Back 180 3 5 1 15 0.27 NFRC 0.19 NFRC Bug Screen 3050 - 2 2 Window S - 762 Back 180 3 5 1 15 0.27 NFRC 0.19 NFRC Bug Screen 2656 - 1 Window S - 762 Back 180 2.5 5.5 1 13.75 0.27 NFRC 0.19 NFRC Bug Screen 2656 - 1 2 Window S - 762 Back 180 2.5 5.5 1 13.75 0.27 NFRC 0.19 NFRC Bug Screen 2656 - 1 3 Window S - 762 Back 180 2.5 5.5 1 13.75 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 Window S - 762 Back 180 1 4 0.27 NFRC 0.2 NFRC Bug Screen 3056 - 3 6 Window S - 762 Back 180 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 7 Window S - 762 Back 180 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 8 Window S - 762 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 9080 - 6 Window W - 197 Right 270 9 8 1 72 0.37 NFRC 0.22 NFRC Bug Screen 2056 - 14 Window N - 373 Front 0 2 5.5 1 11 0.27 NFRC 0.19 NFRC Bug Screen 2056 - 14 2 Window N - 373 Front 0 2 5.5 1 11 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 2 Window N - 373 Front 0 1 4 0.27 NFRC 0.2 NFRC Bug Screen 3056 - 26 Window E - 182 Left 90 3 5.5 1 16.5 0.27 NFRC 0.2 NFRC Bug Screen 3060 - 19 Window S - 373 Back 180 3 6 1 19.01 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 2 Window W - 182 Right 270 3 6 1 19.01 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 3 Window W - 182 Right 270 3 6 1 19.01 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 4 Window W - 182 Right 270 3 6 1 19.01 0.27 NFRC 0.19 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor 3080 - 16 E - 246 24 0.5 3080 - 21 S - 373 24 0.5 Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 9 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3070 - 10 2 2 2 2 0 0 0 0 0 0 0 0 0 3070-52 1 2 3 3 0 0 0 0 0 0 0 0 0 2020 - 15 1 2 3 3 0 0 0 0 0 0 0 0 0 2020 - 15 2 1 2 3 3 0 0 0 0 0 0 0 0 0 3080 -18 3 2 3 3 0 0 0 0 0 0 0 0 0 6020 - 18 3 2 3 3 0 0 0 0 0 0 0 0 0 46100-7-211 3.5 0.1 3.5 3.5 0 0 0 0 0 0 0 0 0 3070 - 10 2 21 4 4 4 0 0 0 0 0 0 0 0 0 180100-8-2R 15 0.1 15 15 0 0 0 0 0 0 0 0 0 11570-9-2R 10 4 10 10 0 0 0 0 0 0 0 0 0 3056 - 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-32 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-33 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-34 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-35 2 2 2 2 0 0 0 0 0 0 0 0 0 3050 - 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3050-22 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 10 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 2656 - 1 2 2 2 2 0 0 0 0 0 0 0 0 0 2656 - 1 2 2 2 2 2 0 0 0 0 0 0 0 0 0 2656 - 1 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-38 2 2 2 2 0 0 0 0 0 0 0 0 0 9080 - 6 3 2 3 3 0 0 0 0 0 0 0 0 0 2056 - 14 2 2 2 2 0 0 0 0 0 0 0 0 0 2056-142 2 2 2 2 0 0 0 0 0 0 0 0 0 3056 - 26 3 2 3 3 0 0 0 0 0 0 0 0 0 3060 - 19 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 4 2 2 2 2 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated 14162 Z1- 1416 1416 0.1 none 0 80% No 14972 Z2 - 1497 1497 0.1 none 0 80% No Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 11 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated 4202 Z3 - 420 420 0.1 none 0 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ1- 1416 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ2 - 1497 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ3 - 420 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 12 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value R 38 Ceilings (below Wood Framed 2x4 @ 24 in. O. C. R 0 None /None 0.481 Cavity / Frame: no insul. / 2x4 attic) Ceiling Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2) n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating Tank Energy Standby Loss # of Input Rating Insulation 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Vol. Factor or or Recovery Units or Pilot R-value or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff DHW Heater 1 Gas Consumer 2 0 0.96-UEF <= 200 0 n/a n/a n/a n/a Instantaneous kBtu/hr Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 13 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Required Verified Heating Cooling Name System Type Heating Unit Cooling Unit Fan Name Distribution Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count Heat Pump Heat Pump Air AC-1 -1 Heat pump heating cooling HVAC Fan 1 Distribution Setback New NA 1 1 System 1 System 1 System 1 Air AC-2 -2 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 2 Distribution Setback New NA 1 1 System 2 System 2 System 2 AC-3 3 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 3 System 3 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Central split HP 1 9.5 60000 42000 16 13 Not Zonal Single Heat Pump System Speed 1-hers-htpump Heat Pump System 2 Central split HP 1 9.5 60000 42000 16 13 Not Zonal Single Heat Pump System Speed 2-hers-htpump Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 14 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 3 VCHP- ducted+ductless 1 9.2 24000 22500 15.5 10.5 Not Zonal Single Speed Heat Pump System 3-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 360 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 360 Required Required Yes Yes Yes Yes 2-hers-htpump Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 3-hers-htpump VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Certified Airflow to Ductless Units Air Filter Sizing Low Leakage Minimum Certified Indoor Fan not Name Low -Static Habitable in Conditioned Wall Mount & Pressure Ducts in Airflow per non -continuous Running VCHP System Rooms Space Thermostat Drop Rating Conditioned RA3.3 and Fan Continuously Space SC3.3.3.4.1 Heat Pump System 3 Required Required Not required Required Required Required Required Required Required Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 15 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return BypasDucts Duct Leakage HERS Verification Air Air Distribution No Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 Tested System Duct 1-hers-d ist Air Air Distribution N0 Sealed and Distribution Unconditioned attic Non Verified R 8 R 8 Attic Attic n/a n/a Bypass System 2 Tested System Duct 2-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design Ducts Handler Conditioned Space Air Distribution yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 1-hers-dirt Air Distribution yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 2-hers-dirt HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.3 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.45 HVAC Fan 2-hers-fan Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 16 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.3 HVAC Fan 2-hers-fan Required 0.45 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness -SRE SFam IAQVentRpt 130 0.25 Default 0 n/a PROJECT NOTES ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. i �da19 LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. -- AC EQUIPMENT'S EFFICIENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. -- ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY. Registration Number: 220-PO 1 0091632D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 14:54:51 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 14:22:38 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 301 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T14:19:10-07:00 (Page 17 of 17) Input File Name: 2R - 033 - ANDALUSIA - PLAN 301- ver 8.2.ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ -�—� Company: Signature Date: TITLE 24 OF THE DESERT 2022-05-06 14:30:29 Address: CEA/ HERS Certification Identification (If applicable): 74800 shirley #62 n.a. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Ruben Romero Responsible Designer Signature: � Company: Date Signed: GLS ARCHITECTURE GROUP INC 2022-05-06 14:54:51 Address: License: 74491 JONI DR SUITE #9 n.a. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: Registration Date/Time: 220-P010091632D-000-000-0000000-0000 2022-05-0614:54:51 CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 HERS Provider: Easy to Verify at CaICERTS.com CaICERTS inc. Report Generated: 2022-05-06 14:22:38 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 301 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/6/2022 Project Address 59000 MADISON CLUB VILLAS ANDAL California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,333 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic no insulation 3,333 Add=R-38.0 New Slab Unheated Slab -on -Grade no insulation 3,333 Perim = 0' New Wall Wood Framed R 21 3,262 New Door Opaque Door - no insulation 48 New FENESTRATION Orientation Area(ft2) Total Area: 872 Glazing Percentage: 26.2% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.31 Exterior Shades Status Front (N) 21.0 0.320 0.25 2.0 none N/A New Front (N) 42.0 0.280 0.22 none none N/A New Front (N) 21.0 0.280 0.22 1.0 none N/A New Front (N) 8.0 0.280 0.22 1.0 none N/A New Left (E) 24.0 0.290 0.17 3.0 none N/A New Left (E) 12.0 0.240 0.22 3.0 none N/A New Rear (S) 45.0 0.360 0.22 3.5 none N/A New Rear (S) 21.0 0.320 0.25 21.0 none N/A New Right (W) 180.0 0.360 0.22 15.0 none N/A New Right (W) 100.0 0.290 0.20 10.0 none N/A New Front (N) 88.0 0.270 0.19 2.0 none N/A New Left (E) 16.5 0.270 0.19 2.0 none N/A New Rear (S) 106.8 0.270 0.19 2.0 none N/A New Rear (S) 4.0 0.270 0.20 none none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status AC-1 - Ducted Ducted Attic 8.0 New AC-2 - Ducted Ducted Attic 8.0 New AC-3 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Instantaneous Gas 0 0.96 Standard New EnegyP,, 8.2 by EnergySoft User Number. 20648 ID: 22 - 20 - GLS 1036 - 0 Page 20 of 28 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 301 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/6/2022 Project Address 59000 MADISON CLUB VILLAS ANDAL California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,333 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: 872 Glazing Percentage: 26.2% New/Altered Average U-Factor: 0.31 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status Rear (S) 33.0 0.270 0.19 none none N/A New Right (W) 72.0 0.370 0.22 3.0 none N/A New Front (N) 4.0 0.270 0.20 none none N/A New Left (E) 16.5 0.270 0.20 3.0 none N/A New Right (W) 57.0 0.270 0.19 2.0 none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 8.2 by EnerqySoft User Number. 20648 ID: 22 - 20 - GLS 1036 - 0 Page 21 of 28 2019 Low -Rise Residential Mandatory Measures Summary NOTE. -Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (01 /2020) Building Envelope Measures: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less § 110.6(a)l: when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.` § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables § 110.6(b): 110.6-A, 110.6-13, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped.* Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, § 110.7: asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services BHGS . § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(i): material must meet the requirements of § 11 0.8i and be labeled per 10-113 when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or § 150.0(c): have a U-factor of 0.071 or less. Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B.` § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without § 150.0(f): facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor § 150.0(g)l: retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a § 150.0(q): maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.` Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)l: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area § 150.0(e)2: and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.` § 150.0(e)3: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.` Space Conditioning, Water Heating, and Plumbing System Measures: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated § 110.0-§ 110.3: appliances must be certified by the manufacturer to the California Energy Commission.` § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.` Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a § 110.2(c): setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)4: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of 110.3(c)4. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose § 110.3(c)6: bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (except § 110.5: appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters.` Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, § 150.0(h)l: Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. 0 2019 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the § 150.0(h)3B: manufacturer's instructions. Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have § 150.00)1: a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water Piping, Solar Water -heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum § 150.00)2A: insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks, buried below grade, and from the heating source to kitchen fixtures.* Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.OQ)3: wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non -crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the § 150.0(n)1: word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit and labeled with the words "Future 240V Use'; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification § 150.0(n)3: Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a § 110.8(d)3: contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be § 150.0(m)1: mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, § 150.0(m)3: mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, § 150.0(m)8: manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed § 150.0(m)9: to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)11 and Reference Residential Appendix RA3. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or § 150.0(m)12: equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.* Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be >_ 350 CFM § 150.0(m)13: per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.45 watts per CFM for gas furnace air handlers and < 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow >_ 250 CFM per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.* 0 2019 Low -Rise Residential Mandatory Measures Summary Requirements for Ventilation and Indoor Air Quality: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation § 150.0(o)1: and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with § 150.0(o)1 C: other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C. Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in accordance with Equation 150.0-13 and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced § 150.0(o)1 E: system is not used, all units in the building must use the same system type and the dwelling -unit envelope leakage must be <_ 0.3 CFM at 50 Pa (0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8. Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide § 150.0(o)1 F: ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be within 20 percent of the unit with the lowest airflow rate as it relates to the individual unit's minimum required airflow rate needed for compliance. § 150.0(o)1 G: Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2. Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential § 150.0(o)2: Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or § 110.4(b)1: dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that § 110.4(b)3: will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § 150.0(p): rate, piping, filters, and valves.' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements §110.9: of§110.9.' § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. § 150.0(k)1 C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an § 150.0(k)1 D: output frequency no less than 20 kHz. § 150.0(k)1 E: Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) § 150.0(k)1 F: must meet the applicable requirements of § 150.0 k .' § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB.' § 150.0(k)1 H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to § 150.0(k)1 I: comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.' Interior Switches and Controls. Lighting must have readily accessible wall -mounted controls that allow the lighting to be manually § 150.0(k)2C: turned ON and OFF.* § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to § 150.0(k)2E: comply with § 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. I�®I 2019 Low -Rise Residential Mandatory Measures Summary v Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it: § 150.0(k)2G: provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.0 e ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it § 150.0(k)2H: provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must § 150.0(k)2I: be controlled by an occupant sensor or a vacancy sensor providing automatic -off functionality. If an occupant sensor is installed, it must be initially configured to manual -on operation using the manual control required under Section 150.0(k)2C. Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for § 150.0(k)2J: dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.` § 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling -installed lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either 150.0 k 3Aii(photocell and either a motion sensor or automatic time switch control or § 150.0 k 3Aiii astronomical time clock), or an EMCS. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances, § 150.0(k)3B: balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots § 150.0(k)3C: or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by § 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of § 150.0(k)4: power as determined according to § 130.0(c). Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the § 150.0(k)5: applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be comply with Table 150.0-A and be controlled by an occupant sensor. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in § 150.0(k)66: that building must: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed must comply with the requirements of § 110.1 0b through § 110.10 e . Low-rise Multifamily Buildings. Low-rise multi -family buildings that do not have a photovoltaic system installed must comply with the § 110.10(a)2: requirements of § 110.10(b) through § 110.10(d). Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with § 110.10(b)1: roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone requirement is applicable to the entire building, including mixed occupancy.* § 110.10(b)2: Azimuth. All sections of the solar zone located on steep -sloped roofs must be oriented between 90 degrees and 300 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof § 110.10(b)3A: mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof § 110.10(b)4: dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a § 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family residences and central water -heating systems, a pathway reserved for routing plumbing from the solar zone to the water -heating system. Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(d): § 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 301 Date 5/6/2022 System Name AC-1 - Floor Area 1,416 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,197 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 60,000 40,136 465 1,676 30,693 Total Output (Btuh) 60,000 0 Output (Btuh/sqft) 42.4 2,317 1,173 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output (Btuh) 60,000 1 1,489 465 -1,489 Total Output (Tons) 5.0 2,317 1,173 Total Output (Btuh/sqft) 42.4 Total Output (sqf /Ton) 283.2 46,259 31,551 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 5 TON 16/13/9.5 42,668 8,036 37,474 Airflow (cfm/sgft) 1.41 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 42,668 8,036 37,474 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 IF Outside Air 0 cfm 67 OF go 67 OF 86 OF B Heating Coil Supply Fan 2,000 cfm 85 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62OF 56/54OF 57/55OF Cooling Coil Supply Fan 58 / 55 OF 2,000 cfm 46.4% ROOM it 75 / 61 OF II�� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 301 Date 5/6/2022 System Name AC-2 - Floor Area 1,497 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,122 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 60,000 38,873 492 1,590 29,193 Total Output (Btuh) 60,000 0 Output (Btuh/sqft) 40.1 2,244 1,116 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output (Btuh) 60,000 1,489 492 -1,489 Total Output (Tons) 5.0 2,244 1,116 Total Output Btuh/sgft 40.1 Total Output s ft/Ton 299.4 1 44,850 29,936 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 5 TON 16/13/9.5 42,608 8,094 37,474 Airflow cfm/sgft 1.34 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 42,608 8,094 37,474 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 67 OF 67 OF 85 OF 86 OF Heating Coil Supply Fan 2,000 cfm 85 OF [ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62°F 56/54°F 57/55°F Cooling Coil Supply Fan 58 / 55 OF 2,000 cfm--W 46.4% Fkoom 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 301 Date 5/6/2022 System Name AC-3 - Floor Area 420 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 599 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 24,000 13,411 138 601 10,906 Total Output (Btuh) 24,000 0 Output (Btuh/sqft) 57.1 774 417 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output (Btuh) 24,000 372 138 -372 Total Output (Tons) 2.0 774 417 Total Output Btuh/sgft 57.1 Total Output s ft/Ton 210.0 1 15,331 11,368 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 2TON 15.5/10.5/9.2 -- 19,837 0 14,990 Airflow cfm/sgft 1.90 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 19,837 0 14,990 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 68 OF 68 OF 85 OF 86 OF Heating Coil Supply Fan 85 OF 800 cfm [ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76/60°F 76/60°F 53/51 OF 53/52°F Cooling Coil Supply Fan 54 / 52 OF 800 cfm 41.9% ROOM 75/60°F BUILDING ENERGY ANALYSIS REPORT I PROJECT: PLAN # 302 59000 MADISON CLUB VILLAS ANDALUSIA C.C. LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 760 340.3528 Report Prepared by: TITLE 24 OF THE DESERT SERVICES INC. title24ofthedesert@gmail.com 760 278.1840, Job Number: 22 - 20 - GLS /036 -034 - 4R - 042 Date: 5/6/2022 REVISION 1 BCPR2020-0024 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 05/11/2022 n,-IF PLAN 302 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 21 Form MF-1 R Mandatory Measures Summary 23 HVAC System Heating and Cooling Loads Summary 27 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 1 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x GENERAL INFORMATION 01 Project Name PLAN 302 ANDALUSIA 02 Run Title Title 24 Analysis 03 Project Location 59000 MADISON CLUB VILLAS ANDALUSIA C.C. 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.31 18 Total Cond. Floor Area (ftZ) 3694 19 Glazing Percentage (%) 24.34% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available? I Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 2 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 47.6 23.4 Proposed Designs North Facing 46.9 22.6 0.7 0.8 East Facing 46.8 22.5 0.8 0.9 South Facing 45.2 20.9 2.4 2.5 West Facing 46.3 22 1.3 1.4 RESULT: 3: COMPLIES ► Efficiency EDR includes improvements to the building envelope and more efficient equipment Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc. s Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 7.18 kWdc • Proposed PV Capacity Scaling: North (7.18 kWdc) East (7.18 kWdc) South (7.18 kWdc) West (7.18 kWdc) Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 3 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x ENERGY USE SUMMARY Energy Use (kTDWft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.17 4.04 -0.87 -27.4 Space Cooling 93.11 89.22 3.89 4.2 IAQ Ventilation 5.86 5.86 0 0 Water Heating 5.77 6.59 -0.82 -14.2 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 107.91 105.71 2.2 2 Space Heating 3.17 4.66 -1.49 -47 Space Cooling 93.11 88.38 4.73 5.1 IAQ Ventilation 5.86 5.86 0 0 Water Heating 5.77 6.59 -0.82 -14.2 Self Utilization Credit n/a pf 0 0 n/a East Facing Compliance Total 107.91 105.49 2.42 2.2 Space Heating 3.17 fta1 4.24 -1.07 -33.8 Space Cooling 93.11 S P R 83.97 9.14 9.8 IAQ Ventilation 5.86 5.86 0 0 Water Heating 5.77 6.59 -0.82 -14.2 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 107.91 100.66 7.25 6.7 Space Heating 3.17 3.88 -0.71 -22.4 Space Cooling 93.11 87.62 5.49 5.9 IAQ Ventilation 5.86 5.86 0 0 Water Heating 5.77 6.59 -0.82 -14.2 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 107.91 103.95 3.96 3.7 Registration Number: 220-P010091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 4 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Tilt: (x in Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) 12) N Solar Access N 7.18 NA Standard Fixed none true 150-270 n/a n/a <=7:12 96 100 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Indoor air quality, balanced fan • Insulation below roof deck • Window overhangs and/or fins • Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) CaICERTS, Inc. HERS PROVIDER Registration Number: Registration Date/Time: HERS Provider: 220-P010091637D-000-000-0000000-0000 2022-05-06 16:25:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 5 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Airflow in habitable rooms (SC3.1.4.1.7) • Minimum Airflow according to RA3.3 and SC3.3.3.4.1 • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity • CEC certified low -static VCHP system • Wall -mounted thermostat in zones greater than 150 ft2 (SC3.4.5) • Verified air filter sizing (SC3.1.4.7) i� , Inc. • Verified air filter pressure drop rating H E R S P R O V I D E R HVAC Distribution System Verifications: • Duct leakage testing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8) Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name z Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems PLAN 302 ANDALUSIA 3694 1 4 4 0 1 Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 6 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Z2 - 1193 Conditioned AC-1 -1 1193 12 DHW Sys 1 N/A Z1- 915 Conditioned AC-2 -2 915 10 DHW Sys 1 N/A Z2 - 1112 Conditioned AC-3 -3 1112 10 DHW Sys 1 N/A Z3 - 474 Conditioned AC-4 -4 474 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) N - 123 Z2 - 1193 R-21 Wall 0 Front 123 60 90 E - 122 Z2 - 1193 R-21 Wall 90 Left 122 24 90 S - 402 Z2 - 1193 R-21 Wall 180 Back 402 92 90 W - 442 Z2 - 1193 R-21 Wall 270 Right 442 244.007 90 N - 440 Z1- 915 R-21 Wall 0 Front 440 33 90 E - 203 Z1- 915 R-21 Wall 90 Left 203 77.505 90 S - 115 Z1- 915 R-21 Wall 180 Back 115 0 90 W - 208 Z1- 915 R-21 Wall 270 Right 208 96 90 N - 405 Z2 - 1112 R-21 Wall 0 Front 405 87 90 E - 122 2 Z2 - 1112 R-21 Wall 90 Left 122 0 90 S - 455 Z2 - 1112 R-21 Wall 180 Back 455 71 90 W - 60 Z2 - 1112 R-21 Wall 270 Right 60 16.5 90 N - 355 Z3 - 474 R-21 Wall 0 Front 355 33 90 E - 155 Z3 - 474 R-21 Wall 90 Left 155 19.25 90 S - 355 Z3 - 474 R-21 Wall 180 Back 355 64 90 W - 155 Z3 - 474 R-21 Wall 270 Right 155 54 90 Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 7 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) TO GARAGE Z3 - 474>>Z1- 915 R-21 Wall1 n/a n/a 184 0 n/a 1193 Z2-1193 R-38 n/a n/a 1193 n/a n/a 915 Z1-915 R-38 n/a n/a 915 n/a n/a 1112 Z2-1112 R-38 n/a n/a 1112 n/a n/a 474 Z3-474 R-38 n/a n/a 474 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Z2 - 1193 Attic RoofZ2 - 1193 Unventilated 4 0.1 0.85 No No Attic Z1- 915 Attic RoofZ1- 915 Unventilated 4 0.1 0.85 No No Attic Z2 - 1112 Attic RoofZ2 - 1112 Unventilated 4 0.1 0.85 No No Attic Z3 - 474 Attic RoofZ3 - 474 Unventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area 2 (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 60100 - 8 Window N - 123 Front 0 6 10 1 60 0.36 NFRC 0.22 NFRC Bug Screen 2020 - 12 Window S - 402 Back 180 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 12 2 Window S - 402 Back 180 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 3070 - 5 Window S - 402 Back 180 3 7 1 21 0.24 NFRC 0.21 NFRC Bug Screen 3070 - 5 2 Window S - 402 Back 180 3 7 1 21 0.24 NFRC 0.21 NFRC Bug Screen 3070 - 5 3 Window S - 402 Back 180 3 7 1 21 0.24 NFRC 0.21 NFRC Bug Screen 6070 - 10 Window S - 402 Back 180 6 7 0 21 0.32 NFRC 0.25 NFRC Bug Screen 12070 - 9 - 413 Window W - 442 Right 270 11 7 1 84.01 1 0.32 1 NFRC 0.25 NFRC Bug Screen Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 8 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 160100 - 7 Window W - 442 Right 270 1 16 10 1 160 0.36 NFRC 0.22 NFRC Bug Screen 3056 - 3 Window N - 440 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 2 Window N - 440 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 3 Window E - 203 Left 90 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 4 Window E - 203 Left 90 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 5 Window E - 203 Left 90 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 Window E - 203 Left 90 3 5 0 4 0.27 NFRC 0.2 NFRC Bug Screen 12080 - 6 Window W - 208 Right 270 12 8 1 96 0.37 NFRC 0.22 NFRC Bug Screen 3060 - 14 Window N - 405 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 14 2 Window N - 405 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 14 3 Window N - 405 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 6 Window N - 405 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 7 Window N - 405 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3050 - 2 Window S - 455 Back 180 3 5 1 15 0.27 NFRC 0.19 NFRC Bug Screen 3050 - 2 2 Window S - 455 Back 180 3 5 1 15 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 8 Window S - 455 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 9 Window S - 455 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 2 Window S - 455 Back 180 2 2 1 4 0.27 NFRC 0.2 NFRC Bug Screen 2020 - 4 3 Window S - 455 Back 180 2 2 1 4 0.27 NFRC 0.2 NFRC Bug Screen 3056 - 3 10 Window W - 60 Right 270 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 11 Window N - 355 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 12 Window N - 355 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3656 - 19 Window E - 155 Left 90 3.5 5.5 1 19.25 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 4 4 Window S - 355 Back 180 2 2 1 4 0.27 NFRC 0.2 NFRC Bug Screen 3060 - 14 4 Window S - 355 Back 180 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 9 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 3060 - 14 5 Window S - 355 Back 180 3 1 6 1 18 0.27 NFRC 1 0.19 NFRC I Bug Screen 3060 - 14 6 Window W - 155 Right 270 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 14 7 Window W - 155 Right 270 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 14 8 Window W - 155 Right 270 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftz) U-factor 3080 E - 122 24 0.5 3080 /???? E - 203 24 0.5 3080 - 16 S - 355 24 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 60100 - 8 21 2 4 4 0 0 0 0 0 0 0 0 0 2020 - 12 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 12 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3070 - 5 2 2 2 2 0 0 0 0 0 0 0 0 0 3070-52 2 2 2 2 0 0 0 0 0 0 0 0 0 3070-53 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 10 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 6070 - 10 2 2 2 2 0 0 0 0 0 0 0 0 0 12070-9-411 9 0.1 9 9 0 0 0 0 0 0 0 0 0 160100-7 9 0.1 9 9 0 0 0 0 0 0 0 0 0 3056 - 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-32 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-33 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-34 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-35 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 4 2 2 2 2 0 0 0 0 0 0 0 0 0 12080 - 6 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3060-143 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-36 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-37 2 2 2 2 0 0 0 0 0 0 0 0 0 3050 - 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3050-22 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 11 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3056-38 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-39 2 2 2 2 0 0 0 0 0 0 0 0 0 2020-42 2 2 2 2 0 0 0 0 0 0 0 0 0 2020-43 2 2 2 2 0 0 0 0 0 0 0 0 0 3056 - 3 10 2 2 2 2 0 0 0 0 0 0 0 0 0 3056 - 3 11 2 2 2 2 0 0 0 0 0 0 0 0 0 3056 - 3 12 2 2 2 2 0 0 0 0 0 0 0 0 0 3656 - 19 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 4 4 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 4 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 5 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 6 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 7 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 14 8 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 12 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated 11932 Z2 - 1193 1193 0.1 none 0 80% No 9152 Z1- 915 915 0.1 none 0 80% No 11122 Z2 - 1112 1112 0.1 none 0 80% No 4742 Z3 - 474 474 0.1 none 0 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value R Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. U R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ2 - 1193 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ1- 915 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 13 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ2 - 1112 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ3 - 474 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. R 38 Ceilings (below Wood Framed 2x4 @ 24 in. O. C. R 0 None None 0.481 Cavity / Frame: no insul. / 2x4 attic) Ceiling Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2) n/a None n/a Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 14 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # of Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Units Vol. Factor or or Pilot R-value or Recovery or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff DHW Heater 1 Gas Consumer 2 0 0.96-UEF <= 200 0 n/a n/a n/a n/a Instantaneous kBtu/hr WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count AC-1 -1 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 1 Air Distribution Setback New NA 1 1 System 1 System 1 System 1 AC-2 2 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 2 System 2 AC-3 3 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 3 System 3 AC-4 4 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 4 System 4 Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 15 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Central split HP 1 9.5 48000 36000 16 13 Not Zonal Single Heat Pump System Speed 1-hers-htpump Heat Pump System 2 VCHP-ducted 1 9.2 30000 22500 15.5 10.5 Not Zonal Single Heat Pump System Speed 2-hers-htpump Heat Pump System 3 VCHP-ducted 1 9.2 30000 22500 15.5 10.5 Not Zonal Single Heat Pump System Speed 3-hers-htpump Heat Pump System 4 VCHP-ducted 1 9.2 24000 22500 15.5 10.5 Not Zonal Single Heat Pump System Speed 4-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 360 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 2-hers-htpump Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 4-hers-htpump Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 16 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Certified Airflow to Ductless Units Air Filter Sizing Low Leakage Minimum Certified Indoor Fan not Name Low -Static Habitable in Conditioned Wall Mount & Pressure Ducts in Airflow per non -continuous Running VCHP System Rooms Space Thermostat Drop Rating Conditioned RA3.3 and Fan Continuously Space SC3.3.3.4.1 Heat Pump System 2 Required Required Not required Required Required Required Required Required Required Heat Pump System 3 Required Required Not required Required Required Required Required Required Required Heat Pump System 4 Required Required Not required Required Required Required Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return BypasDucts Duct Leakage HERS Verification Air Air Distribution NO Sealed and Distribution Unconditioned attic Non Verified R 8 R 8 Attic Attic n/a n/a Bypass System 1 Tested System Duct 1-hers-d ist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design Ducts Handler Conditioned Space Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 1-hers-dirt Registration Number: 220-PO 1 0091637D-000-000-0000000-0000 Registration Date/Time: 2022-05-06 16:25:09 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 16:17:09 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 17 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness -SRE SFam IAQVentRpt 1-1 40 0.575 Balanced 0 n/a SFam IAQVentRpt 2-1 40 0.575 Balanced 0 n/a SFam IAQVentRpt 3-1 40 0.575 Balanced 0 n/a SFam IAQVentRpt 4-1 40 0.575 Balanced 0 n/a PROJECT NOTES ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. AC EQUIPMENT'S EFFICIENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY. Registration Number: 220-P010091637D-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2019 Residential Compliance Registration Date/Time: 2022-05-06 16:25:09 Report Version: 2019.1.300 Schema Version: rev 20200901 HERS Provider: CaICERTS inc. Report Generated: 2022-05-06 16:17:09 CERTIFICATE OF COMPLIANCE Project Name: PLAN 302 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T16:13:08-07:00 (Page 18 of 18) Input File Name: 4R - VER 8.2 - 034 - ANDALUSIA - PLAN 302.ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ -�—� Company: Signature Date: TITLE 24 OF THE DESERT 2022-05-06 16:24:23 Address: CEA/ HERS Certification Identification (If applicable): 74800 shirley #62 n.a. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Ruben Romero Responsible Designer Signature: � Company: Date Signed: GLS ARCHITECTURE GROUP INC 2022-05-06 16:25:09 Address: License: 74491 JONI DR SUITE #9 n.a. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: Registration Date/Time: 220-P010091637D-000-000-0000000-0000 2022-05-0616:25:09 CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 HERS Provider: Easy to Verify at CaICERTS.com CaICERTS inc. Report Generated: 2022-05-06 16:17:09 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 302 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/6/2022 Project Address 59000 MADISON CLUB VILLAS ANDAL California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,694 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic no insulation 3,694 Add=R-38.0 New Slab Unheated Slab -on -Grade no insulation 3,694 Perim = 0' New Wall Wood Framed R 21 3,330 New Door Opaque Door - no insulation 72 New FENESTRATION Orientation Area(ft2) Total Area: 899 Glazing Percentage: 24.3% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.31 Exterior Shades Status Front (N) 60.0 0.360 0.22 21.0 none N/A New Rear (S) 8.0 0.280 0.22 2.0 none N/A New Rear (S) 63.0 0.240 0.21 2.0 none N/A New Rear (S) 21.0 0.320 0.25 2.0 none N/A New Right (W) 84.0 0.320 0.25 9.0 none N/A New Right (W) 160.0 0.360 0.22 9.0 none N/A New Front (N) 153.0 0.270 0.19 2.0 none N/A New Left (E) 49.5 0.270 0.19 2.0 none N/A New Left (E) 4.0 0.270 0.20 2.0 none N/A New Right (W) 96.0 0.370 0.22 2.0 none N/A New Rear (S) 99.0 0.270 0.19 2.0 none N/A New Rear (S) 12.0 0.270 0.20 2.0 none N/A New Right (W) 70.5 0.270 0.19 2.0 none N/A New Left (E) 19.3 0.280 0.22 2.0 none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status AC-1 - Ducted Ducted Attic 8.0 New AC-2 - Ducted Ducted Attic 8.0 New AC-3 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Instantaneous Gas 0 0.96 Standard New EnegyP,, 8.2 by EnergySoft User Number. 20648 ID: 22 - 20 - GLS 1036 -0; Page 21 of 30 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 302 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/6/2022 Project Address 59000 MADISON CLUB VILLAS ANDAL California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,694 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: 899 Glazing Percentage: 24.3% New/Altered Average U-Factor: 0.31 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status AC-4 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EegyP,, 8.2 by EnerqySoft User Number. 20648 ID: 22 - 20 - GLS 1036 -0; Page 22 of 30 2019 Low -Rise Residential Mandatory Measures Summary NOTE. -Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (01 /2020) Building Envelope Measures: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less § 110.6(a)l: when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.` § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables § 110.6(b): 110.6-A, 110.6-13, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped.* Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, § 110.7: asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services BHGS . § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(i): material must meet the requirements of § 11 0.8i and be labeled per 10-113 when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or § 150.0(c): have a U-factor of 0.071 or less. Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B.` § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without § 150.0(f): facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor § 150.0(g)l: retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a § 150.0(q): maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.` Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)l: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area § 150.0(e)2: and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.` § 150.0(e)3: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.` Space Conditioning, Water Heating, and Plumbing System Measures: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated § 110.0-§ 110.3: appliances must be certified by the manufacturer to the California Energy Commission.` § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.` Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a § 110.2(c): setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)4: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of 110.3(c)4. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose § 110.3(c)6: bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (except § 110.5: appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters.` Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, § 150.0(h)l: Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. 0 2019 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the § 150.0(h)3B: manufacturer's instructions. Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have § 150.00)1: a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water Piping, Solar Water -heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum § 150.00)2A: insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks, buried below grade, and from the heating source to kitchen fixtures.* Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.OQ)3: wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non -crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the § 150.0(n)1: word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit and labeled with the words "Future 240V Use'; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification § 150.0(n)3: Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a § 110.8(d)3: contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be § 150.0(m)1: mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, § 150.0(m)3: mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, § 150.0(m)8: manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed § 150.0(m)9: to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)11 and Reference Residential Appendix RA3. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or § 150.0(m)12: equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.* Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be >_ 350 CFM § 150.0(m)13: per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.45 watts per CFM for gas furnace air handlers and < 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow >_ 250 CFM per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.* 0 2019 Low -Rise Residential Mandatory Measures Summary Requirements for Ventilation and Indoor Air Quality: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation § 150.0(o)1: and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with § 150.0(o)1 C: other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C. Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in accordance with Equation 150.0-13 and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced § 150.0(o)1 E: system is not used, all units in the building must use the same system type and the dwelling -unit envelope leakage must be <_ 0.3 CFM at 50 Pa (0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8. Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide § 150.0(o)1 F: ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be within 20 percent of the unit with the lowest airflow rate as it relates to the individual unit's minimum required airflow rate needed for compliance. § 150.0(o)1 G: Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2. Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential § 150.0(o)2: Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or § 110.4(b)1: dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that § 110.4(b)3: will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § 150.0(p): rate, piping, filters, and valves.' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements §110.9: of§110.9.' § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. § 150.0(k)1 C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an § 150.0(k)1 D: output frequency no less than 20 kHz. § 150.0(k)1 E: Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) § 150.0(k)1 F: must meet the applicable requirements of § 150.0 k .' § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB.' § 150.0(k)1 H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to § 150.0(k)1 I: comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.' Interior Switches and Controls. Lighting must have readily accessible wall -mounted controls that allow the lighting to be manually § 150.0(k)2C: turned ON and OFF.* § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to § 150.0(k)2E: comply with § 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. I�®I 2019 Low -Rise Residential Mandatory Measures Summary v Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it: § 150.0(k)2G: provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.0 e ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it § 150.0(k)2H: provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must § 150.0(k)2I: be controlled by an occupant sensor or a vacancy sensor providing automatic -off functionality. If an occupant sensor is installed, it must be initially configured to manual -on operation using the manual control required under Section 150.0(k)2C. Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for § 150.0(k)2J: dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.` § 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling -installed lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either 150.0 k 3Aii(photocell and either a motion sensor or automatic time switch control or § 150.0 k 3Aiii astronomical time clock), or an EMCS. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances, § 150.0(k)3B: balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots § 150.0(k)3C: or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by § 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of § 150.0(k)4: power as determined according to § 130.0(c). Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the § 150.0(k)5: applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be comply with Table 150.0-A and be controlled by an occupant sensor. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in § 150.0(k)66: that building must: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed must comply with the requirements of § 110.1 0b through § 110.10 e . Low-rise Multifamily Buildings. Low-rise multi -family buildings that do not have a photovoltaic system installed must comply with the § 110.10(a)2: requirements of § 110.10(b) through § 110.10(d). Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with § 110.10(b)1: roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone requirement is applicable to the entire building, including mixed occupancy.* § 110.10(b)2: Azimuth. All sections of the solar zone located on steep -sloped roofs must be oriented between 90 degrees and 300 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof § 110.10(b)3A: mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof § 110.10(b)4: dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a § 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family residences and central water -heating systems, a pathway reserved for routing plumbing from the solar zone to the water -heating system. Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(d): § 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 302 Date 5/6/2022 System Name AC-1 - Floor Area 1,193 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,762 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 48,000 33,719 395 645 25,621 Total Output (Btuh) 48,000 0 Output (Btuh/sqft) 40.2 1,947 980 Cooling System 0 0 Output per System 48,000 0 0 0 0 Total Output (Btuh) 48,000 1,489 395 -1,489 Total Output (Tons) 4.0 1,947 980 Total Output Btuh/sgft 40.2 Total Output s ft/Ton 298.3 1 39,101 26,091 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 4 TON 16/13/9.5 -- 37,153 3,383 29,979 Airflow cfm/sgft 1.34 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 37,153 3,383 29,979 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 67 OF 67 OF 105 OF 106 OF -Il I I I Heating Coil Supply Fan 1,600 cfm 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62°F 55/54°F 56/54°F Cooling Coil Supply Fan 57 / 55 OF 1,600 cfm--W 46.2% Fkoom 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 302 Date 5/6/2022 System Name AC-2 - Floor Area 915 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,326 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 30,000 25,755 303 481 18,763 Total Output (Btuh) 30,000 0 Output (Btuh/sqft) 32.8 1,487 717 Cooling System 0 0 Output per System 30,000 0 0 0 0 Total Output (Btuh) 30,000 372 303 -372 Total Output (Tons) 2.5 1,487 717 Total Output Btuh/sgft 32.8 Total Output s ft/Ton 366.0 1 29,100 19,826 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 2.5 TON 15.5/10.5/9.2 -- 25,372 0 18,737 Airflow cfm/sgft 1.09 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 25,372 0 18,737 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air -4 r- 0 cfm 67 OF 67 OF 105 OF 105 OF E -Il I I I Heating Coil Supply Fan 1,000 cfm 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 57 / 55 OF 1,000 cfm--W 46.2% Fkoom 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 302 Date 5/6/2022 System Name AC-3 - Floor Area 1,112 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,428 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 30,000 27,588 368 539 21,003 Total Output (Btuh) 30,000 0 Output (Btuh/sqft) 27.0 1,593 803 Cooling System 0 0 Output per System 30,000 0 0 0 0 Total Output (Btuh) 30,000 372 368 -372 Total Output (Tons) 2•5 1,593 803 Total Output Btuh/sgft 27.0 Total Output s ft/Ton 444.8 1 31,146 22,237 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 2.5 TON 15.5/10.5/9.2 -- 25,393 0 18,737 Airflow cfm/sgft 0.90 Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 25,393 0 18,737 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air -4 r- 0 cfm 67 OF 67 OF 105 OF 105 OF E -Il I I I Heating Coil Supply Fan 1,000 cfm 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 57 / 55 OF 1,000 cfm--W 46.3% Fkoom 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 302 Date 5/6/2022 System Name AC-4 - Floor Area 474 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 745 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 24,000 14,720 157 297 11,673 Total Output (Btuh) 24,000 0 Output (Btuh/sqft) 50.6 850 446 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output (Btuh) 24,000 1 372 157 -372 Total Output (Tons) 2.0 1 850 446 Total Output (Btuh/sqft) 50.6 Total Output (sqf /Ton) 237.0 16,791 12,193 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow (cfm) 800 2TON 15.5/10.5/9.2 -- 20,249 0 14,990 Airflow (cfm/sgft) 1.69 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 20,249 0 14,990 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 IF Outside Air 0 cfm 67 OF 67 OF E Heating Coil Supply Fan 800 cfm flU 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76 / 62 IF 76/62OF 55/54OF 55/54OF Cooling Coil Supply Fan 56 / 54 OF 800 cfm 46.2% ROOM 75 / 61 OF BUILDING ENERGY ANALYSIS REPORT I PROJECT: PLAN # 303 59000 MADISON CLUB VILLAS ANDALUSIA C.C. LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. REVISION 1 74991 JONI DR #9 BCPR2020-0024 PALM DESERT, CA 92260 CITY OF LA QUINTA 760 340.3528 BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE p,,05/11/2022 PLAN 303 Report Prepared by: TITLE 24 OF THE DESERT SERVICES INC. title24ofthedesert@gmail.com 760 278.1840, Job Number: 22 - 20 - GLS /036 -035 - 4R - 043 Date: 5/6/2022 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 22 Form MF-1 R Mandatory Measures Summary 24 HVAC System Heating and Cooling Loads Summary 28 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 1 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x GENERAL INFORMATION 01 Project Name PLAN 303 ANDALUSIA 02 Run Title Title 24 Analysis 03 Project Location 59000 MADISON CLUB VILLAS ANDALUSIA C.C. 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.31 18 Total Cond. Floor Area (ftZ) 4038 19 Glazing Percentage (%) 23.54% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available? I Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 2 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 45.3 22.6 Proposed Designs North Facing 43.5 20.7 1.8 1.9 East Facing 45 22.2 0.3 0.4 South Facing 41.8 19.1 3.5 3.5 West Facing 44.5 21.7 0.8 0.9 RESULT: 3: COMPLIES ► Efficiency EDR includes improvements to the building envelope and more efficient equipment Z Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries nc. s Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 7.00 kWdc • Proposed PV Capacity Scaling: North (7.00 kWdc) East (7.00 kWdc) South (7.00 kWdc) West (7.00 kWdc) Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 3 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x ENERGY USE SUMMARY Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.35 3.84 -1.49 -63.4 Space Cooling 86.41 79.04 7.37 8.5 IAQ Ventilation 2.17 2.17 0 0 Water Heating 5.28 6.03 -0.75 -14.2 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 96.21 91.08 5.13 5.3 Space Heating 2.35 4.33 -1.98 -84.3 Space Cooling 86.41 82.68 3.73 4.3 IAQ Ventilation 2.17 2.17 0 0 Water Heating 5.28 6.03 -0.75 -14.2 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 96.21 rr:DT 95.21 1 1 Space Heating 2.35 3.65 -1.3 -55.3 Space Cooling 86.41 S P R 74.48 11.93 13.8 IAQ Ventilation 2.17 2.17 0 0 Water Heating 5.28 6.03 -0.75 -14.2 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 96.21 86.33 9.88 10.3 Space Heating 2.35 3.75 -1.4 -59.6 Space Cooling 86.41 82 4.41 5.1 IAQ Ventilation 2.17 2.17 0 0 Water Heating 5.28 6.03 -0.75 -14.2 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 96.21 93.95 2.26 2.3 Registration Number: 220-P010091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 4 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Tilt: (x in Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) 12) N Solar Access N 7 NA Standard Fixed none true 150-270 n/a n/a <=7:12 96 100 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins • Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) ,IlkHERS PROVIDER CaICERTS, Inc. Registration Number: Registration Date/Time: HERS Provider: 220-P010091643E-000-000-0000000-0000 2022-05-06 18:29:33 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 5 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Airflow in habitable rooms (SC3.1.4.1.7) • Minimum Airflow according to RA3.3 and SC3.3.3.4.1 • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity • CEC certified low -static VCHP system • Wall -mounted thermostat in zones greater than 150 ft2 (SC3.4.5) • Verified air filter sizing (SC3.1.4.7) i� , Inc. • Verified air filter pressure drop rating H E R S P R O V I D E R HVAC Distribution System Verifications: • Duct leakage testing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8) Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name z Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems PLAN 303 ANDALUSIA 4038 1 4 4 0 1 Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 6 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Z1- 1596 Conditioned AC-1 -1 1596 12 DHW Sys 1 N/A Z2 - 960 Conditioned AC-2 -2 960 10 DHW Sys 1 N/A Z3 - 962 Conditioned AC-3 -3 962 10 DHW Sys 1 N/A Z4 - 520 Conditioned AC-4 -4 520 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) N - 636 Z1- 1596 R-21 Wall 0 Front 636 109.5 90 E - 326 Z1- 1596 R-21 Wall 90 Left 326 36 90 S - 122 Z1- 1596 R-21 Wall 180 Back 122 80 90 W - 460 Z1- 1596 R-21 Wall 270 Right 460 256 90 S - 283 Z2 - 960 R-21 Wall 180 Back 283 33 90 S - 283 2 Z2 - 960 R-21 Wall 180 Back 283 46 90 W - 203 Z2 - 960 R-21 Wall 270 Right 203 120 90 N - 593 Z3 - 962 R-21 Wall 0 Front 593 105 90 E - 67 Z3 - 962 R-21 Wall 90 Left 67 12 90 S - 245 Z3 - 962 R-21 Wall 180 Back 245 41.5 90 S - 245 2 Z3 - 962 R-21 Wall 180 Back 245 20.5 90 N - 370 Z4 - 520 R-21 Wall 0 Front 370 4 90 E - 60 Z4 - 520 R-21 Wall 90 Left 60 6 90 S - 370 Z4 - 520 R-21 Wall 180 Back 370 69 90 W - 234 Z4 - 520 R-21 Wall 270 Right 234 60 90 TO GARAGE Z4 - 520>>Z1- 1596 R-21 Wall1 n/a n/a 184 0 n/a Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 7 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) 1596 Z1- 1596 R-38 n/a n/a 1596 n/a n/a 960 Z2-960 R-38 n/a n/a 960 n/a n/a 962 Z3-962 R-38 n/a n/a 962 n/a n/a 520 Z4-520 R-38 n/a n/a 520 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Z1- 1596 Attic RoofZ1- 1596 Unventilated 4 0.1 0.85 No No Attic Z2 - 960 Attic RoofZ2 - 960 Unventilated 4 0.1 0.85 No No Attic Z3 - 962 Attic RoofZ3 - 962 Unventilated 4 0.1 0.85 No No Attic Z4 - 520 Attic RoofZ4 - 520 Unventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading 3670 - 10 Window N - 636 Front 0 3.5 7 1 24.5 0.32 NFRC 0.25 NFRC Bug Screen 3070 - 5 Window N - 636 Front 0 3 7 1 21 0.28 NFRC 0.22 NFRC Bug Screen 4070 - 13 Window N - 636 Front 0 4 7 1 28 0.24 NFRC 0.21 NFRC Bug Screen 4070 - 14 Window N - 636 Front 0 4 7 1 28 0.32 NFRC 0.25 NFRC Bug Screen 2020 - 15 Window N - 636 Front 0 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 15 2 Window N - 636 Front 0 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 15 3 Window E - 326 Left 90 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 15 4 Window E - 326 Left 90 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen 2020 - 15 5 Window E - 326 Left 90 2 2 1 4 0.28 NFRC 0.22 NFRC Bug Screen Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 8 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 80100 - 7 Window S - 122 Back 180 8 10 1 80 0.36 NFRC 0.22 NFRC Bug Screen 200100 - 8 -4R Window W - 460 Right 270 20 10 1 200 0.36 NFRC 0.22 NFRC Bug Screen 8070 - 9 Window W - 460 Right 270 8 7 1 56 0.32 NFRC 0.25 NFRC Bug Screen 3056 - 3 Window S - 283 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 2 Window S - 283 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 Window S - 283 2 Back 180 2 2 1 4 0.27 NFRC 0.2 NFRC Bug Screen 3070 - 5 2 Window S - 283 2 Back 180 3 7 1 21 0.28 NFRC 0.22 NFRC Bug Screen 3070 - 5 3 Window S - 283 2 Back 180 3 7 1 21 0.28 NFRC 0.22 NFRC Bug Screen 120100 - 6 Window W - 203 Right 270 12 10 1 120 0.37 NFRC 0.22 NFRC Bug Screen 3060 - 19 Window N - 593 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 2 Window N - 593 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 3 Window N - 593 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 4 Window N - 593 Front 0 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 3 Window N - 593 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 4 Window N - 593 Front 0 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 2060 - 18 Window E - 67 Left 90 2 6 1 12 0.27 NFRC 0.19 NFRC Bug Screen 2640 - 1 Window S - 245 Back 180 2.5 4 1 10 0.27 NFRC 0.19 NFRC Bug Screen 3050 - 2 Window S - 245 Back 180 3 5 1 15 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 5 Window S - 245 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 6 Window S - 245 2 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 2 Window S - 245 2 Back 180 2 2 1 4 0.27 NFRC 0.19 NFRC Bug Screen 2020 - 4 3 Window N - 370 Front 0 2 2 1 4 0.27 NFRC 0.2 NFRC Bug Screen 2030 - 24 Window E - 60 Left 90 2 3 1 6 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 Window S - 370 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen 3056 - 3 2 Window S - 370 Back 180 3 5.5 1 16.5 0.27 NFRC 0.19 NFRC Bug Screen Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 9 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) MuIt. Area z (ft) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading 3060 - 19 5 Window S - 370 Back 180 3 1 6 1 18 0.27 NFRC 1 0.19 NFRC I Bug Screen 3060 - 19 6 Window S - 370 Back 180 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 7 Window W - 234 Right 270 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen 3060 - 19 8 Window W - 234 Right 270 3 6 1 18 0.27 NFRC 0.19 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftz) U-factor 3080 - 16 E - 326 24 0.5 3080 W - 234 24 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3670 - 10 2 2 2 2 0 0 0 0 0 0 0 0 0 3070 - 5 2 2 2 2 0 0 0 0 0 0 0 0 0 4070 - 13 2 2 2 2 0 0 0 0 0 0 0 0 0 4070 - 14 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 15 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 15 2 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 10 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 2020 - 15 3 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 15 4 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 15 5 2 2 2 2 0 0 0 0 0 0 0 0 0 80100 - 7 15 0.1 15 15 0 0 0 0 0 0 0 0 0 200100 - 8 -4R 15 0.1 15 15 0 0 0 0 0 0 0 0 0 8070 - 9 21 2 4 4 0 0 0 0 0 0 0 0 0 3056 - 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-32 2 2 2 2 0 0 0 0 0 0 0 0 0 2020 - 4 2 2 2 2 0 0 0 0 0 0 0 0 0 3070-52 2 2 2 2 0 0 0 0 0 0 0 0 0 3070-53 2 2 2 2 0 0 0 0 0 0 0 0 0 120100-6 12 2 12 12 0 0 0 0 0 0 0 0 0 3060 - 19 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 4 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-33 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 11 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3056-34 2 2 2 2 0 0 0 0 0 0 0 0 0 2060 - 18 2 2 2 2 0 0 0 0 0 0 0 0 0 2640 - 1 2 2 2 2 0 0 0 0 0 0 0 0 0 3050 - 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-35 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-36 2 2 2 2 0 0 0 0 0 0 0 0 0 2020-42 2 2 2 2 0 0 0 0 0 0 0 0 0 2020-43 2 2 2 2 0 0 0 0 0 0 0 0 0 2030 - 24 2 2 2 2 0 0 0 0 0 0 0 0 0 3056 - 3 2 2 2 2 0 0 0 0 0 0 0 0 0 3056-32 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 5 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 6 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 7 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 - 19 8 2 2 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 12 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated 1596 2 Z1- 1596 1596 0.1 none 0 80% No 480 Z2 - 960 480 0.1 none 0 80% No 4802 Z2 - 960 480 0.1 none 0 80% No 9622 Z3 - 962 962 0.1 none 0 80% No 5202 Z4 - 520 520 0.1 none 0 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ1- 1596 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 13 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ2 - 960 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ3 - 962 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. t r� Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofZ4 - 520 Attic Roofs 2x4 @ 24 in. 0. C. R-38 None / None 0.037 Siding/sheathing/decking Ceiling a �s a i rs IF a s Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. R-38 -- Ceilings (below Wood Framed 2x4 @ 24 in. 0. C. R-0 None None / 0.481 Cavity / Frame: no insul. / 2x4 attic) Ceiling Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 14 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2) n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # of Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Units Vol. Factor or or Pilot R-value or Recovery or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff DHW Heater 1 Gas Consumer 2 0 0.96-UEF <= 200 0 n/a n/a n/a n/a Instantaneous kBtu/hr WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Required Verified Heating Cooling Name System Type Heating Unit Cooling Unit Fan Name Distribution Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count Air AC-1 -1 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 1 Distribution Setback New NA 1 1 System 1 System 1 System 1 AC-2 2 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 2 System 2 Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 15 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Required Verified Heating Cooling Name System Type Heating Unit Cooling Unit Fan Name Distribution Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count AC-3 3 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 3 System 3 AC-4 -4 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 4 System 4 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Heating Cooling Zonally Compressor Name System Type Number of Units HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Controlled Type Heat Pump System 1 Central split HP 1 9.5 60000 42000 16 13 Not Zonal Single Heat Pump System Speed 1-hers-htpump Heat Pump System 2 VCHP- 1 9.2 30000 22500 15.5 10.5 Not Zonal Single Heat Pump System ducted+ductless Speed 2-hers-htpump Heat Pump System 3 VCHP- 1 9.2 30000 22500 15.5 10.5 Not Zonal Single Heat Pump System ducted+ductless Speed 3-hers-htpump Heat Pump System 4 VCHP- 1 9.2 24000 22500 15.5 10.5 Not Zonal Single Heat Pump System ducted+ductless Speed 4-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 360 Required Required Yes Yes Yes Yes 1-hers-htpump Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 16 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 2-hers-htpump Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Not Required 0 Not Required Required Yes Yes Yes Yes 4-hers-htpump VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Certified Airflow to Ductless Units Air Filter Sizing Low Leakage Minimum Certified Indoor Fan not Name Low -Static Habitable in Conditioned Wall Mount & Pressure Ducts in Airflow per non -continuous Running VCHP System Rooms Space Thermostat Drop Rating Conditioned RA3.3 and Fan Continuously Space SC3.3.3.4.1 Heat Pump System 2 Required Required Not required Required Required Required Required Required Required Heat Pump System 3 Required Required Not required Required Required Required Required Required Required Heat Pump System 4 Required Required Not required Required Required Required Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Leakage HERS Verification Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 Tested System Duct 1-hers-d ist Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 17 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design Ducts Handler Conditioned Space Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 1-hers-dirt HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness -SRE SFam IAQVentRpt 149 0.25 Default 0 n/a PROJECT NOTES Registration Number: 220-PO 1 0091643E-000-000-0000000-0000 Registration Date/Time: 2022-05-06 18:29:33 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2022-05-06 18:21:05 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 18 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x --ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. --LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. AC EQUIPMENT'S EFFICENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY. � CaICERTS, Inc. Registration Number: 220-P010091643E-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2019 Residential Compliance Registration Date/Time: 2022-05-06 18:29:33 Report Version: 2019.1.300 Schema Version: rev 20200901 HERS Provider: CaICERTS inc. Report Generated: 2022-05-06 18:21:05 CERTIFICATE OF COMPLIANCE Project Name: PLAN 303 ANDALUSIA Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-05-06T18:17:03-07:00 (Page 19 of 19) Input File Name: 4R - VER 8.2 - 035 - ANDALUSIA - PLAN 303.ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ -�—� Company: Signature Date: TITLE 24 OF THE DESERT 2022-05-06 18:28:56 Address: CEA/ HERS Certification Identification (If applicable): 74800 shirley #62 n.a. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Ruben Romero Responsible Designer Signature: � Company: Date Signed: GLS ARCHITECTURE GROUP INC 2022-05-06 18:29:33 Address: License: 74491 JONI DR SUITE #9 n.a. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: Registration Date/Time: 220-P010091643E-000-000-0000000-0000 2022-05-0618:29:33 CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 HERS Provider: 0 ❑' Easy to Verify at CaICERTS.com CaICERTS inc. Report Generated: 2022-05-06 18:21:05 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 303 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/6/2022 Project Address 59000 MADISON CLUB VILLAS ANDAL California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,038 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic no insulation 4,038 Add=R-38.0 New Slab Unheated Slab -on -Grade no insulation 4,038 Perim = 0' New Wall Wood Framed R 21 3,683 New Door Opaque Door - no insulation 48 New FENESTRATION Orientation Area(ft) Total Area: 951 Glazing Percentage: 23.5% U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.31 Exterior Shades Status Front (N) 52.5 0.320 0.25 2.0 none N/A New Front (N) 29.0 0.280 0.22 2.0 none N/A New Front (N) 28.0 0.240 0.21 2.0 none N/A New Left (E) 12.0 0.280 0.22 2.0 none N/A New Rear (S) 80.0 0.360 0.22 15.0 none N/A New Right (W) 200.0 0.360 0.22 15.0 none N/A New Right (W) 56.0 0.320 0.25 21.0 none N/A New Rear (S) 164.0 0.270 0.19 2.0 none N/A New Rear (S) 4.0 0.270 0.20 2.0 none N/A New Rear (S) 42.0 0.280 0.22 2.0 none N/A New Right (W) 120.0 0.370 0.22 12.0 none N/A New Front (N) 105.0 0.270 0.19 2.0 none N/A New Left (E) 18.0 0.270 0.19 2.0 none N/A New Front (N) 4.0 0.270 0.20 2.0 none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status AC-1 - Ducted Ducted Attic 8.0 New AC-2 - Ducted Ducted Attic 8.0 New AC-3 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Instantaneous Gas 0 0.96 Standard New EnegyP,, 8.2 by EnergySoft User Number. 20648 ID: 22 - 20 - GLS 1036 -0; Page 22 of 31 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name PLAN # 303 Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/6/2022 Project Address 59000 MADISON CLUB VILLAS ANDAL California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,038 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: 951 Glazing Percentage: 23.5% New/Altered Average U-Factor: 0.31 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status Right (W) 36.0 0.270 0.19 2.0 none N/A New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.20 HSPF Split Heat Pump 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status AC-4 - Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnegyP,, 8.2 by EnergySoft User Number. 20648 ID: 22 - 20 - GLS 1036 -0; Page 23 of 31 2019 Low -Rise Residential Mandatory Measures Summary NOTE. -Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (01 /2020) Building Envelope Measures: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less § 110.6(a)l: when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.` § 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a). Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables § 110.6(b): 110.6-A, 110.6-13, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped.* Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, § 110.7: asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services BHGS . § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(i): material must meet the requirements of § 11 0.8i and be labeled per 10-113 when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or § 150.0(c): have a U-factor of 0.071 or less. Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B.` § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without § 150.0(f): facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor § 150.0(g)l: retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a § 150.0(q): maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.` Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0(e)l: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area § 150.0(e)2: and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.` § 150.0(e)3: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.` Space Conditioning, Water Heating, and Plumbing System Measures: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated § 110.0-§ 110.3: appliances must be certified by the manufacturer to the California Energy Commission.` § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.` Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a § 110.2(c): setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)4: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of 110.3(c)4. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose § 110.3(c)6: bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (except § 110.5: appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters.` Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook, § 150.0(h)l: Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2. 0 2019 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the § 150.0(h)3B: manufacturer's instructions. Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have § 150.00)1: a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water Piping, Solar Water -heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum § 150.00)2A: insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks, buried below grade, and from the heating source to kitchen fixtures.* Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.OQ)3: wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non -crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the § 150.0(n)1: word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit and labeled with the words "Future 240V Use'; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification § 150.0(n)3: Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a § 110.8(d)3: contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be § 150.0(m)1: mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, § 150.0(m)3: mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, § 150.0(m)8: manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed § 150.0(m)9: to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)11 and Reference Residential Appendix RA3. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or § 150.0(m)12: equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.* Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be >_ 350 CFM § 150.0(m)13: per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.45 watts per CFM for gas furnace air handlers and < 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow >_ 250 CFM per ton of nominal cooling capacity, and an air -handling unit fan efficacy < 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.* 0 2019 Low -Rise Residential Mandatory Measures Summary Requirements for Ventilation and Indoor Air Quality: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation § 150.0(o)1: and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with § 150.0(o)1 C: other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C. Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in accordance with Equation 150.0-13 and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced § 150.0(o)1 E: system is not used, all units in the building must use the same system type and the dwelling -unit envelope leakage must be <_ 0.3 CFM at 50 Pa (0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8. Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide § 150.0(o)1 F: ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be within 20 percent of the unit with the lowest airflow rate as it relates to the individual unit's minimum required airflow rate needed for compliance. § 150.0(o)1 G: Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2. Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential § 150.0(o)2: Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or § 110.4(b)1: dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that § 110.4(b)3: will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § 150.0(p): rate, piping, filters, and valves.' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements §110.9: of§110.9.' § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. § 150.0(k)1 C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an § 150.0(k)1 D: output frequency no less than 20 kHz. § 150.0(k)1 E: Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) § 150.0(k)1 F: must meet the applicable requirements of § 150.0 k .' § 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JAB.' § 150.0(k)1 H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to § 150.0(k)1 I: comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.' Interior Switches and Controls. Lighting must have readily accessible wall -mounted controls that allow the lighting to be manually § 150.0(k)2C: turned ON and OFF.* § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to § 150.0(k)2E: comply with § 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. I�®I 2019 Low -Rise Residential Mandatory Measures Summary v Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it: § 150.0(k)2G: provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.0 e ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it § 150.0(k)2H: provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must § 150.0(k)2I: be controlled by an occupant sensor or a vacancy sensor providing automatic -off functionality. If an occupant sensor is installed, it must be initially configured to manual -on operation using the manual control required under Section 150.0(k)2C. Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for § 150.0(k)2J: dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.` § 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling -installed lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either 150.0 k 3Aii(photocell and either a motion sensor or automatic time switch control or § 150.0 k 3Aiii astronomical time clock), or an EMCS. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances, § 150.0(k)3B: balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots § 150.0(k)3C: or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by § 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of § 150.0(k)4: power as determined according to § 130.0(c). Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the § 150.0(k)5: applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be comply with Table 150.0-A and be controlled by an occupant sensor. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in § 150.0(k)66: that building must: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic system installed must comply with the requirements of § 110.1 0b through § 110.10 e . Low-rise Multifamily Buildings. Low-rise multi -family buildings that do not have a photovoltaic system installed must comply with the § 110.10(a)2: requirements of § 110.10(b) through § 110.10(d). Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with § 110.10(b)1: roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone requirement is applicable to the entire building, including mixed occupancy.* § 110.10(b)2: Azimuth. All sections of the solar zone located on steep -sloped roofs must be oriented between 90 degrees and 300 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof § 110.10(b)3A: mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof § 110.10(b)4: dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a § 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family residences and central water -heating systems, a pathway reserved for routing plumbing from the solar zone to the water -heating system. Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(d): § 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 303 Date 5/6/2022 System Name AC-1 - Floor Area 1,596 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,099 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 60,000 43,561 526 1,857 33,779 Total Output (Btuh) 60,000 0 Output (Btuh/sqft) 37.6 2,515 1,291 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output (Btuh) 60,000 1,489 526 -1,489 Total Output (Tons) 5.0 2,515 1,291 Total Output (Btuh/sqft) 37.6 Total Output (sqf /Ton) 319.2 50,080 34,873 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 5TON 16/13/9.5 - SEER/EER/HSPF - 48,025 2,068 37,474 Airflow (cfm/sgft) 1.25 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 48,025 2,068 37,474 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 IF Outside Air 0 cfm 67 OF go 67 OF 86 OF B Heating Coil Supply Fan 2,000 cfm 85 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76/61 OF 76/61OF 54/52OF 54/53OF Cooling Coil Supply Fan 55 / 53 OF 2,000 cfm 43.7% ROOM Iff 75/61 OF II�� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 303 Date 5/6/2022 System Name AC-2 - Floor Area 960 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,561 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 30,000 32,633 316 1,058 18,709 Total Output (Btuh) 30,000 0 Output (Btuh/sqft) 31.3 1,884 715 Cooling System 0 0 Output per System 30,000 0 0 0 0 Total Output (Btuh) 30,000 372 316 -372 Total Output (Tons) 2.5 1,884 715 Total Output Btuh/sgft 31.3 Total Output s ft/Ton 384.0 1 36,773 19,768 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 2.5 TON 15.5/10.5/9.2 -- 25,042 0 18,737 Airflow cfm/sgft 1.04 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 25,042 0 18,737 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 67 OF 67 OF 85 OF 85 OF Heating Coil Supply Fan 85 OF 1,000 cfm [ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 77/61 OF 77/61OF 53/52OF 54/52OF Cooling Coil Supply Fan 55 / 53 OF 1,000 cfm 43.0% ROOM Iff 75/60OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 303 Date 5/6/2022 System Name AC-3 - Floor Area 962 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,518 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 30,000 31,855 317 1,086 19,154 Total Output (Btuh) 30,000 0 Output (Btuh/sqft) 31.2 1,839 732 Cooling System 0 0 Output per System 30,000 0 0 0 0 Total Output (Btuh) 30,000 372 317 -372 Total Output (Tons) 2.5 1,839 732 Total Output Btuh/sgft 31.2 Total Output s ft/Ton 384.8 1 35,905 20,247 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 2.5 TON 15.5/10.5/9.2 -- 25,031 0 18,737 Airflow cfm/sgft 1.04 Airflow cfm/Ton 400.0 Outside Air ova 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 25,031 0 18,737 Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 67 OF 67 OF 85 OF 85 OF Heating Coil Supply Fan 85 OF 1,000 cfm [ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 77/61 OF 77/61OF 53/52OF 54/52OF Cooling Coil Supply Fan 55 / 53 OF 1,000 cfm 42.9% ROOM Iff 75/60OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name PLAN # 303 Date 5/6/2022 System Name AC-4 - Floor Area 520 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 678 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 24,000 15,039 171 673 12,139 Total Output (Btuh) 24,000 0 Output (Btuh/sqft) 46.2 868 464 Cooling System 0 0 Output per System 24,000 0 0 0 0 Total Output (Btuh) 24,000 372 171 -372 Total Output (Tons) 2.0 868 464 Total Output (Btuh/sqft) 46.2 Total Output (sqf /Ton) 260.0 17,147 12,695 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow (cfm) 800 2TON 15.5/10.5/9.2 -- 19,864 0 14,990 Airflow (cfm/sgft) 1.54 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 19,864 0 14,990 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 IF Outside Air 0 cfm 67 OF go 67 OF 85 OF Heating Coil Supply Fan 85 OF 800 cfm ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/73OF Outside Air 0 cfm 76/61 OF 76/61 OF 53/51 OF 53/52°F Cooling Coil Supply Fan 54 / 52 OF 800 cfm 42.0% ROOM 75/60°F II II�� Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201(760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA. 92543 (951) 766-8777 Fax (951) 766-8778 February 19, 2020 National Mortgage and Land Company 81570 Carboneras La Quinta, California 92253 Subject: . Geotechnical Update BCPR2020-0022 Project No. 544-18139 ANDALUSIA / TRACT 20-02-079 CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR Project: Andalusia at Coral Mountain CODE COMPLIANCE Tract No. 31681--Remaining Phases DAT102/16/2021 „ JP La Quinta, California Ref: Geotechnical Investigation report prepared by Sladden Engineering dated September 5, 2018; Project No. 544-18139, Report No.18-09-441 In accordance with your request, we have reviewed the above referenced Geotechnical Investigation report as it relates to the design and construction of the residential structures proposed for the remaining lots within the Andalusia at Coral Mountain development in the City of La Quinta, California. It is our understanding that the proposed residences will be of relatively lightweight wood -frame construction and will be supported by conventional shallow spread footings and post -tensioned slabs on grade. The referenced report includes recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced report, our previous experience of the project site and our understanding of the proposed construction, it is our opinion that the structural values included in the referenced Geotedmical Investigation report remain applicable for the design and construction of the proposed residential structures. Post -tensioned slabs are proposed for the proposed residential structures in order to mitigate potential liquefaction related differential seismic settlements. We have evaluated the on -site soil for construction of post -tensioned foundation systems in general accordance with design specifications of the Post Tensioning Institute (PTI). Post -tensioned slabs should be designed to be rigid and capable of spanning areas of non -uniform support and meet the following criteria: 1. Bearing Capacity =1500 psf 2. Potential Liquefaction Induced Differential Settlement = 2.25 inches (over a horizontal distance of 100 feet) 3. Coefficient of Friction = 0.40 Sladden Engineering February 19, 2020 -2- Project No. 544-18139 20-02-079 Auxiliary structures may be supported upon conventional shallow spread footings. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings may be designed utilizing allowable bearing pressures of 1800 psf and 2000 psf, respectively. Allowable increases of 250 psf for each additional 1 foot of width and 250 psf for each additional 6 inches of depth may be utilized, if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Static settlement resulting from the anticipated foundation loads should be minimal provided that the recommendations included in this report are considered in foundation design and construction. The ultimate static settlement is estimated to be less than one inch when using the recommended foundation bearing pressures. As a practical matter, differential static settlement between footings can be assumed as one-half of the total static settlement. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.40 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 250 pcf. if used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. Retaining walls may be necessary to accomplish the proposed construction. Lateral pressures for use in retaining wall design can be estimated using an equivalent fluid weight of 35 pcf for level free -draining native backfill conditions. For walls that are to be restrained at the top, the equivalent fluid weight should be increased to 55 pcf for level free -draining native backfill conditions. Back drains should be provided for the full height of the walls. Seismic pressures should be incorporated into any retaining walls greater than 6 feet in height. Seismic deign pressures may be provided once specific wall heights and locations are known design pressures can be provided. The seismic design category for a structure may be determined in accordance with Section 1613 of the 2019 CBC or ASCE7-16. According to the 2019 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2019 CBC Site Specific Seismic Hazard Analyses are attached. Because the remaining lots have been previously rough graded, the remedial grading required at this time should be minimal provided that the building areas fall within the previously assumed building envelopes. The building areas should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. Any loosely dumped stockpiled material should be removed to the certified engineered fill soil remaining from the previous rough grading operations. The exposed surface should be scarified, brought to near optimum moisture content and compacted to a minimum of 90 percent relative compaction prior to fill placement. The previously removed soil and any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. Sladden Engineering February 19, 2020 -3- Project No. 544-18139 20-02-079 We appreciate the opportunity to provide service to you on this project. If you have any questions regarding this letter or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. A Principal Q Gr- SS1pN� BREfT L. �4�lQERSON No. C45389 2 _ n CIVIL ENGINEERING, SER/ra ��F CAS Copies: 4/ Addressee Ratthew J. Cohrt ,I 2 Principal Geologist kL) 4EEarN0 Q� 0 EW ,I. rOHRT O G� 2634 ~ \F 0�F CAJ1/FCC Sladden Engineering Please verify that soils reports contain all of the above information. In addition, to assure continuity beNveen the investigationlreporting stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required elements. Only then can we be assured that the construction documents address all of the site soil conditions. La Quinta Geotechnical Report Checklist Does the 'Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means: (a) the criterion is considered significant and mitigation measure(s) noted, or; (b) the criterion is considered insignificant and explicitly so stated. files . No Criterion fQ © Foundation criteria based upon bearing capacity of natural or compacted soil. I� ❑ Foundation criteria to mitigate the effects of expansive soils. U. ❑ Foundation criteria based upon bearing capacity. of natural or compacted soil_ ❑ Foundation criteria to midgate.the effects of liquefaction. i] ❑ Foundation criteria to mitigate the effects of selsmlcally Induced differential sottlement. ❑"" ❑ Foundation criteria to mitigate the effects of long-term differential settlement_ 1121"' ❑ Foundation criteria to mitigate the effects of varying soil strength. L� ❑ Foundation criteria to mitigate expected total and differential settlement. Any "No" answers to the -above checklist should be noted as specific required corrections. # # # �OQROFESS/6 l3RETt L. ANDERSON No. G45389 m �u m CIVIL ;TJ ENGINEERING �c FOF CAt��O� - Project: Andalusia -Remaining Phases Project Number: 544.18139 Client: National Mortgage and Land Company Site Lat/Long; 33.6212/-116,2420 Controlling Seismic Source: Southern San Andreas REFERENCE NOTATION VALUE Site Class A, 8, C, D, E or F D (Site Class D (Measured) only) Site Class D - 21.2.2.(ii) F, 1 Site Class D - 21.2.2.(ii) F 2.5 0.2'(SD1/Sos) To 0.136 Sol/SOS Ts 0.681 Fundamental Period (12.8.2) T Period Seismic Design Maps or Fig 22-14 T1 8 2/3'sm, Sol 0.681 Fv'S, SMi 1.021 RISK COEFFICIENT REFERENCE F„ (Table 11.4-2)[1.15ed for General Spectrum) Design Maps Design Maps Design Maps Design Maps Design Maps Equation 11.8.1 Section 21.5.3 Design Maps Design Maps Cr - At Perods <=0.2, Cr=CRS Cr 0.913 Cr - At Periods >=1.0,Cr=Cr1 Cr 0.894 0.915 Cr - At Periods between 0.2 and 1.0 Period Cr 0.91 use trendline formula to complete 0.200 0.913 0.300 0.911 0.905 0.400 0.909 0.500 0.906 0.600 0.904 0.9 0.680 0.902 1.000 0.894 0.395 0 39 0.000 Sladden Engineering NOTATION F Sns SOS S, FPG- PGA PGA,,, 8C% of PGAM CR1 Crs Cr Interpolation 0.2 to 1.0 VALUE 1.7 ��1.500 l� 0.600 1.1 0.582 0.640 0.512 0.894 0.913 y = .0.0233x - 0.9173 0 2co 0,400 0.600 0.300 1.000 1.200 DETERMINISTIC SPECTRUM AND LOWER LIMIT Largest Amplitudes of Ground Motions Considering All Sources Calculated using Weighted Mean of Attenuation Equations*. Controlling Source: Southern San Andreas Period DETERMINISTIC (RAW) DETERMINISTIC LOWER LIMIT DETERMINISTIC MCE 84 FRACTILE 0.005 0.638 0.623 0,020 0.651 0.692 0.030 0.681 0.739 0.040 0.717 0.785 0.050 0.752 0.831 0.060 0.804 0.877 0,080 0.906 0.970 0, 70 0.090 0.958 1.016 0.100 1.008 1.062 0.120 1.096 1.154 0.136 1.156 1.228 0,200 1.236 1.500 1. 5 C, -01 0.300 1.292 1.500 0.400 1.286 1.500 0.500 1,304 1.500 0.600 1.288 1,500 0,680 1.277 1.500 1.000 1,175 1.500 1.200 1.094 1,250 2,000 0.832 0.750 n., q 3.000 0.644 0.500 4.000 0.499 0.375 1 5.000 1 0.388 1 0.300 *Attenuation Equations Boore - Atkinson (2008) NGA USGS 2008 M R C Campbell - Bozorgnia (2008) NGA USGS 2008 MRC - Youngs (2007) NGA USGS 2008 MRC 0 Sladden Engineering Deterministic PGA: 0.638 Project No: 544-18139 S.Ow —Deterministic Lower Un* — Deterministic (RAW) — — Deterministic MCE Project No: 544-18139 idea ROOtw 4*09 2 50 - - - -- -*.Boore-Atkinson (2008) NGA USGS 2008 MRC I PRPBABILISTIC MCER ! I__ —I t—Campbell-3ozorgnla(2008) NGA U5GS2008MRC Chiou-Youngs(2007) NGA USG52008 MRC —'- `---- -- —' �— SPECTRAL RESPONSE ACCELERATIONS ! I FProbablllsticMCE 2.00 t .I. i I - -r--•+ .-- + I I ! I I I- I � � I I I � � I Analysis Information L00 I , JI 1 I I _ I I I ! I I _ _ _ Spectral Response @ 5 % Damping -- ;_ with Maximum Rotated Component. Probability of Exceedence: t t--1 + - ,— - __�� i I I •I—�—; _I i'_i ;^I 2%In 50 years f - -- - �_r.� i---fir I- I T I o.00 OAM LOW 2000 3.000 4.000 5.000 Period (seconds) PROBABILISTIC SPECTRA 2% in 50 year Exceedence Risk Coefficient Probabilistic Period B- A C- B C- Y Mean (CR) MCE 0.005 0.89 0.83 u.98 0.90 0.913 0.823 0.020 0.91 0.83 1.00 0.92 0.913 0.837 0.030 0.95 0.87 1.04 0.96 0.913 0.877 0.040 1.00 0.94 1.09 1.02 0.913 0.929 0.050 1.03 1.00 1.16 1.07 0.913 0.974 0.060 1.11 1.08 1.23 1.14 0.913 1.044 0.080 1.27 1.23 1.40 1.30 0.913 1.191 0.090 1.35 1.31 1.49 1.39 0.913 1.267 0.100 1.43 1.39 1.58 1.47 0.913 1.344 0.120 1.56 1.51 1.76 1.61 0.913 1.474 0.136 1.65 1.61 1.87 1.71 0.913 1.564 0.200 1.80 1.78 2.06 1.89 0.913 " .724 0.300 1.82 1.69 2.03 1.86 0.911 1.695 0.400 1.79 1.58 1.89 1.75 0.908 1,.593 0.500 1.76 1.52 1.70 1.66 0.906 i.506 0.600 1.66 1.44 1.57 1.56 0.904 , .407 0.680 1.59 1.39 1.49 1.50 0.902 J .348 1.000 1.27 1.24 1.30 1.27 0.894 i.136 1.200 1.14 1.13 1.16 1.14 0.894 ' .021 2.000 0.77 0.83 0.76 0.79 0.894 0.706 3.000 0.55 0.58 0.32 0.55 0.894 0.491 4.000 0.41 0.45 0.38 0.42 0.894 0.373 5.000 0.35 0.40 0.28 0.35 0.894 0.310 B-A - Boore-Atkinson (2008) NGA USGS 2008 MRC C-B - Campbell-Bozorgnia (2008) NGA USGS 2008 MRC C-Y - Chiou-Youngs (2007) NGA USGS 2008 MRC Sladden Engineering Probabilistic PGA: 0.823 Project No: 544-18139 SITE SPECIFIC SPECTRA Period Probabilistic MCE Deterministic MCE Site -Specific MCE Design Response Spectrum (Sal 0.005 0.823 -- _ 0.638 0.020 3.837 0.692 0.692 0.462 0.030 0.877 0.739 0.739 0.492 0.040 0.929 0.785 0.785 0.523 0.050 0.974 0.831 0.831 0.554 0.060 1.044 0.877 0.877 0.585 0.080 1.191 0.970 0.970 0.646 0.090 1.267 1.016 1.016 11.677 0.100 1.344 1.062 1.062 .708 0.120 1.474 1.154 1.154 0.770 0.136 1.564 1.228 1.228 0.819 0.200 1.724 1.500 1.500 1.000 0.300 1.695 1.500 1.500 1.000 0.400 1.593 1.500 1.500 1.000 0.500 1.506 1.500 1.500 1.000 0.600 1.407 1.500 1.407 0.938 0.680 1.348 1.500 1.348 0.899 1.000 1.136 1.500 1.136 0.758 1.200 1.021 1.250 1.021 0.681 2.000 0.706 0.832 0.706 0.470 3.000 0.491 0.644 0.491 0.327 4.000 0.373 0.499 0.373 0.249 5.000 0.310 0.388 0.310 �.207 SDS: SD1: SMS: SM1: Site Specific PGAm Site Class: Sladden Engineering ASCE 7-16: Section 21.4 Calculated Design Value Value 0.900 0.900 1.035 1.035 1.350 1.350 1.552 1.552 0.638 0.638 D - measured Period ASCE 7 SECTION 11.4.6 General Spectrum 80% General Response Spectrum 0.005 0.422 0.338 0.010 0.444 0.355 0.030 0.532 0.426 0.040 0.576 0.461 0.050 0.620 0.496 0.060 0.664 0.531 0.080 0.752 0.602 0.090 0.797 0.637 0.100 0.841 0.672 0.110 0.885 0.708 0.120 0.929 0.743 0.136 0.999 0.799 0.150 1.000 0.900 0.160 1.000 0.800 0.170 1.000 0.800 0.180 1.000 0.800 0.190 1.000 0.800 0.200 1.000 0.800 0.300 1.000 0.800 0.400 1.000 0.800 0.500 1.000 0.800 0.600 1.000 0.800 0.640 1.000 0.800 0.680 1.000 0.800 0.850 0.801 0.641 0.900 0.757 0.605 0.950 0.717 0.573 1.000 0.681 0.545 1.200 0.567 0.454 2.000 0.340 0.272 3.000 0.227 0.182 4.000 0.170 0.136 5.000 0.136 0.109 Project No: 544-18139 Probabilistic MCE Deterministic MCE - J- Site -Specific MCE Design Response Spectrum --OE—ASCE 7 Section 11.4.6 General Spectrum 80% General Response Spectrum Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201(760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 www.Sladdcnenginecring.com December 29, 2020 Project No. 544-18139 20-12-625 National Mortgage and Land Company 81570 Carboneras La Quinta, California 92253 Project: Andalusia at Coral Mountain Tract No. 31681— Remaining Phases Tract No. 37790 — Club Villas La Quinta, California Reviewed for Code Compliance 02/09/2021 Interwest Consulting Group Subject: Foundation Plan Review — Plan 301 Ref: Geotechnical Investigation report prepared by Sladden Engineering dated September 5, 2018; Project No. 544-18139, Report No. 18-09-441 In accordance with your request, we have reviewed the Foundation Plans and Details prepared by Gouvis Engineering. The plans reviewed including PT Foundation Plan 301A, 301A Reverse, 301B and 301C were prepared for the future residences to be constructed within the Andalusia at Coral Mountain development in the City of La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Investigation report have been properly incorporated into these plans. If you have questions regarding this memo or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING OQ�p�ESS/ BRETT L. 2 pNDERSON F v) No. C,45389 0 Brett L. Anderson CN1L � Principal Engineer *_ E ERING Letter/ra �C Copies: 4 / National Mortgage and Land Company BCPR2020-0022 ANDALUSIA / TRACT CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ,ATF02/16/2021 PLAN 301 Sladden Engineering www. Sladdenengineering. eom Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 www.Sladdenengincering.com December 29, 2020 National Mortgage and Land Company 81570 Carboneras La Quinta, California 92253 Project: Andalusia at Coral Mountain Tract No. 31681— Remaining Phases Tract No. 37790 — Club Villas La Quinta, California Subject: Foundation Plan Review — Plan 302 Project No. 544-18139 20-12-626 Ref: Geotechnical Investigation report prepared by Sladden Engineering dated September 5, 2018; Project No. 544-18139, Report No. 18-09-441 In accordance with your request, we have reviewed the Foundation Plans and Details prepared by. Gouvis Engineering. The plans reviewed including PT Foundation Plan 302A, 302A Reverse, 302B and 302C were prepared for the future residences to be constructed within the Andalusia at Coral Mountain development in the City of La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Investigation report have been properly incorporated into these plans. If you have questions regarding this memo or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. Anderson Principal Engineer Letter/ra Copies: 4 / National Mortgage and Land Company BCPR2020-0022 ANDALUSIA / TRACT CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE IA1102/16/2021 , 'J= PLAN 302 Sladden Engineering www.Sladdenengineering. com (W Sladden Engineering 45090 GolfCenter Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 www.Sladdenengineering.com December 29, 2020 National Mortgage and Land Company 81570 Carboneras La Quinta, California 92253 Project: Andalusia at Coral Mountain Tract No. 31681— Remaining Phases Tract No. 37790 — Club Villas La Quinta, California Subject: Foundation Plan Review — Plan 303 Project No. 544-18139 20-12-627 Reviewed for Code Compliance 02/09/2021 Interwest Consulting Group Ref: Geotechnical Investigation report prepared by Sladden Engineering dated September 5, 2018; Project No. 544-18139, Report No. 18-09-441 In accordance with your request, we have reviewed the Foundation Plans and Details prepared by Golivis Engineering. The plans reviewed including PT Foundation Plan 303A, 303A Reverse, 303B and 303C were prepared for the future residences to be constructed within the Andalusia at Coral Mountain development in the City of La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Investigation report have been properly incorporated into these plans. If you have questions regarding this memo or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. Anderson Principal Engineer Letter/ra BRETT L. C . NDEFISON 5389 CNIL * ENGINEERING , OFCP�� BCPR2020-0022 ANDALUSIA / TRACT CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE IA1102/16/2021 Copies: 4 / National Mortgage and Land Company PLAN 303 Sladden Engineering www.Sladdenengineering.com Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 www.Sladdencnginecring.com December 29, 2020 Project No. 544-18139 20-12-628 National Mortgage and Land Company 81570 Carboneras La Quinta, California 92253 Project: Andalusia at Coral Mountain Tract No. 31681 — Remaining Phases Tract No. 37790 — Club Villas La Quinta, California Subject: Foundation Plan Review — Plan 401 Reviewed for Code Compliance) 02/09/2021 Interwest Consulting Group Ref: Geotechnical Investigation report prepared by Sladden Engineering dated September 5, 2018; Project No. 544-18139, Report No. 18-09-441 In accordance with your request, we have reviewed the Foundation Plans and Details prepared by Gouvis Engineering. The plans reviewed including PT Foundation Plan 401A, 401A Reverse, 401B and 401C were prepared for the future residences to be constructed within the Andalusia at Coral Mountain development in the City of La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Investigation report have been properly incorporated into these plans. If you have questions regarding this memo or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. Anderson Principal Engineer Letter/ra pnCi aREr 1 •���� ANDERS6I Z G, r 389 n * eNGINNIL f Nj BRING y 9 �F CAI IFS:° Copies: 4 / National Mortgage and Land Company BCPR2020-0022 ANDALUSIA/TRACT CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE oArr02/16/2021 �~ PLAN 401 Sladden Engineering www.Sladdenengineering.com Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 www.Sladdenengineering.com December 29, 2020 Project No. 544-18139 20-12-629 National Mortgage and Land Company 81570 Carboneras La Quinta, California 92253 Project: Andalusia at Coral Mountain Tract No. 31681 — Remaining Phases Tract No. 37790 — Club Villas La Quinta, California Subject: Foundation Plan Review — Plan 402 Reviewed for Code Compliance 02/09/2021 Interwest Consulting Group Ref: Geotechnical Investigation report prepared by Sladden Engineering dated September 5, 2018; Project No. 544-18139, Report No. 18-09-441 In accordance with your request, we have reviewed the Foundation Plans and Details prepared by Gouvis Engineering. The plans reviewed including PT Foundation Plan 402A, 402A Reverse, 402B and 402C were prepared for the future residences to be constructed within the Andalusia at Coral Mountain development in the City of La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Investigation report have been properly incorporated into these plans. If you have questions regarding this memo or the referenced report, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING BREfT L. `y ANDERSON G Brett L. Anderson No. C45389 Principal Engineer C ENGINEERING Letter/ra OF cAl Copies: 4 / National Mortgage and Land Company BCPR2020-0022 ANDALUSIA / TRACT CONSTRUCTION PLANS 300 & 400 SERIES (SFDx5). [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ,,,02/16/2021 h J� PLAN 402 Sladden Engineering www.Sladdenengineering.eoin