Loading...
BRES2021-0910 Title 24CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribd19x CF1R-PRF-01E (Page 1 of 24) GENERAL INFORMATION 01 Project Name Madison Lot 39A 02 Run Title Title 24 Analysis 03 Project Location Lot 39A -The Madison Club 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.3 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 160 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 10 14 Addition Cond. Floor Area (ft) 0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U-factor 0.33 18 Total Cond. Floor Area (ft) 17398 19 Glazing Percentage (%) 21.91% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available? I Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 06/22/2022 eY__D C Registration Number: BRES2021-0910 - 53821 ROSS AVENUE LOT 39 MADISON LLC / 17,398SF DWELLING 17,398SF DWELLING - LOT 39 [VB/RES-3/CLASS A-FR/13D]. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH [RES ENGINEERING]. 2019 CALIFORNIA BUILDING CODES. 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name: Madison Lot 39A Calculation Date/Time: 2022-03-21T09:56:40-07:00 (Page 2 of 24) Calculation Description: Title 24 Analysis Input File Name: Madison Lot 39A-Radford-21.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency' (EDR) TotalZ (EDR) Efficiency' (EDR) TotalZ (EDR) Standard Design 38.6 20.4 Proposed Design 37.8 19.7 0.8 0.7 RESULT: 3: COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 21.33 kWdc ENERGY USE SUMMARY Energy Use (kTDV/ftz-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.39 4.19 -0.8 -23.6 Space Cooling 73.74 71.02 2.72 3.7 IAQ Ventilation 2.37 2.37 0 0 Water Heating 1.6 1.52 0.08 5 Self Utilization/Flexibility Credit n/a 0 0 n/a Compliance Energy Total 81.1 79.1 2 2.5 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Tilt: (x in Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) 12) N Solar Access N 20 NA Standard Fixed none false 180 Degre 22 4.85 96 100 es Registration Number: Registration Date/Time: HERS Provider: 222-P010053098A-000-000-0000000-0000 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins • Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY CF1R-PRF-01E (Page 3 of 24) The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF CaICERTS, Inc. • Verified heat pump rated heating capacity H E R S P R O V I D E R HVAC Distribution System Verifications: • Duct leakage testing • Ducts located entirely in conditioned space confirmed by duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftZ) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Lot 39A 17398 1 10 10 0 2 Registration Number: Registration Date/Time: HERS Provider: 222-P010053098A-000-000-0000000-0000 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 4 of 24) ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Bedroom 1 Conditioned AC 11 1990 11 DHW Sys 1 N/A Office Conditioned AC 22 1021 11 DHW Sys 1 N/A Entry/Kitchen/Dining Conditioned AC 33 2093 14 DHW Sys 1 N/A Great Room Conditioned AC 44 1581 23 DHW Sys 1 N/A Bedroom 2 Conditioned AC 55 1623 11 DHW Sys 1 N/A Rec/Media Conditioned AC 66 1844 11 DHW Sys 1 N/A Bedroom 3/1-aundry Conditioned AC 66 985 11 DHW Sys 1 N/A Guest House Conditioned AC 77 2228 11 DHW Sys 3 N/A Bedroom 4 Conditioned AC 8 & 98 1981 9 DHW Sys 3 N/A Bedroom 5 Conditioned AC 10 & 119 2052 11 DHW Sys 3 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) N Wall Bedroom 1 R-21 Wall (W.21.2x6.16) 0 n/a 480 140.5 90 E Wall Bedroom 1 R-21 Wall (W.21.2x6.16) 90 n/a 200 25 90 S Wall Bedroom 1 R-21 Wall (W.21.2x6.16) 180 n/a 276 0 90 W Wall Bedroom 1 R-21 Wall (W.21.2x6.16) 270 n/a 644 176 90 N Wall 2 Office R-21 Wall (W.21.2x6.16) 0 n/a 308 85.5 90 E Wall 2 Office R-21 Wall (W.21.2x6.16) 90 n/a 374 132 90 W Wall 2 Office R-21 Wall (W.21.2x6.16) 270 n/a 44 0 90 Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 5 of 24) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) E Wall 3 Entry/Kitchen/Dining R-21 Wall (W.21.2x6.16) 90 n/a 713 602.924 90 S Wall 2 Entry/Kitchen/Dining R-21 Wall (W.21.2x6.16) 180 n/a 176 81 90 W Wall 3 Great Room R-21 Wall (W.21.2x6.16) 270 n/a 1058 798 90 N Wall 3 Bedroom 2 R-21 Wall (W.21.2x6.16) 0 n/a 154 0 90 E Wall 4 Bedroom 2 R-21 Wall (W.21.2x6.16) 90 n/a 44 0 90 S Wall 3 Bedroom 2 R-21 Wall (W.21.2x6.16) 180 n/a 594 70.722 90 W Wall 4 Bedroom 2 R-21 Wall (W.21.2x6.16) 270 n/a 352 176 90 N Wall 4 Rec/Media R-21 Wall (W.21.2x6.16) 0 n/a 352 220 90 E Wall 5 Rec/Media R-21 Wall (W.21.2x6.16) 90 n/a 88 0 90 S Wall 4 Rec/Media R-21 Wall (W.21.2x6.16) 180 n/a 608 0 90 W Wall 5 Rec/Media R-21 Wall (W.21.2x6.16) 270 n/a 44 0 90 N Wall 5 Bedroom 3/1-aundry R-21 Wall (W.21.2x6.16) 0 n/a 110 20 90 E Wall 6 Bedroom 3/1-aundry R-21 Wall (W.21.2x6.16) 90 n/a 484 0 90 S Wall 5 Bedroom 3/1-aundry R-21 Wall (W.21.2x6.16) 180 n/a 418 108.5 90 W Wall 6 Bedroom 3/1-aundry R-21 Wall (W.21.2x6.16) 270 n/a 55 0 90 N Wall 6 Guest House R-21 Wall (W.21.2x6.16) 0 n/a 660 80 90 E Wall 7 Guest House R-21 Wall (W.21.2x6.16) 90 n/a 484 160 90 S Wall 6 Guest House R-21 Wall (W.21.2x6.16) 180 n/a 660 102.5 90 W Wall 7 Guest House R-21 Wall (W.21.2x6.16) 270 n/a 464 258.5 90 N Wall 7 Bedroom 4 R-21 Wall (W.21.2x6.16) 0 n/a 702 132.5 90 E Wall 8 Bedroom 4 R-21 Wall (W.21.2x6.16) 90 n/a 468 10 90 W Wall 8 Bedroom 4 R-21 Wall (W.21.2x6.16) 270 n/a 288 144 90 E Wall 9 Bedroom 5 R-21 Wall (W.21.2x6.16) 90 n/a 432 20 90 S Wall 7 Bedroom 5 R-21 Wall (W.21.2x6.16) 180 n/a 702 120 90 W Wall 9 Bedroom 5 R-21 Wall (W.21.2x6.16) 270 n/a 234 144 90 Interior Surface Bedroom 1»Office R-0 Interior Wall n/a n/a 280 0 n/a Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 6 of 24) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Tilt (deg) Area (ft2) Bedroom 1»Great Interior Surface 2 R-0 Interior Wall n/a n/a 325 0 n/a Room Interior Surface 3 Off ice»Bedroom 1 R-0 Interior Wall n/a n/a 280 0 n/a Entry/Kitchen/Dining» Interior Surface 4 R 0 Interior Wall n/a n/a 280 0 n/a Office Entry/Kitchen/Dining» Interior Surface 5 R 0 Interior Wall n/a n/a 506 0 n/a Great Room Great Interior Surface 6 Room>>Entry/Kitchen/ R-0 Interior Wall n/a n/a 506 0 n/a Dining Great Room»Bedroom Interior Surface 7 R-0 Interior Wall n/a n/a 325 0 n/a 1 Great Room»Bedroom Interior Surface 8 R-0 Interior Wall n/a n/a 325 0 n/a 2 Interior Surface 9 Bedroom 2»Office R-0 Interior Wall n/a n/a 280 0 n/a Bedroom 2»GreatRoom Interior Surface 10 R 0 Interior Wall n/a n/a 325 0 n/a Rec/Media»Bedroom Interior Surface 11 R 0 Interior Wall n/a n/a 280 0 n/a 3/Laundry Bedroom Interior Surface 12 R-0 Interior Wall n/a n/a 280 0 n/a 3/Laundry»Rec/Media Bedroom 4»Bedroom5 Interior Surface 13 R-0 Interior Wall n/a n/a 600 0 n/a Bedroom 5»Bedroom4 Interior Surface 14 R-0 Interior Wall n/a n/a 600 0 n/a Roof 2 Bedroom 1 R-38 + R-19 n/a n/a 1990 n/a n/a Roof 3 Office R-38 + R-19 n/a n/a 585 n/a n/a Roof 4 Entry/Kitchen/Dining R-38 + R-19 n/a n/a 2093 n/a n/a Roof 5 Great Room R-38 + R-19 n/a n/a 1581 n/a n/a Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 7 of 24) OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) Roof 6 Bedroom 2 R-38 + R-19 n/a n/a 1623 n/a n/a Roof 7 Rec/Media R-38 + R-19 n/a n/a 1844 n/a n/a Roof 8 Bedroom 3/1-aundry R-38 + R-19 n/a n/a 985 n/a n/a Roof 9 Guest House R-38 + R-19 n/a n/a 2224 n/a n/a Roof 10 Bedroom 4 R-38 + R-19 n/a n/a 1981 n/a n/a Roof 11 Bedroom 5 R-38 + R-19 n/a n/a 2052 n/a n/a Raised Floor Bedroom 4 R-19 Floor n/a n/a 1982 n/a n/a Raised Floor 2 Bedroom 5 R-19 Floor n/a n/a 2052 n/a n/a OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Guest House R-38 + R-191 270 n/a 4.1 4 3 0.1 0.85 No ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Bedroom 1 Attic RoofBedroom 1 Unventilated 3 0.1 0.85 No No Attic Office Attic RoofOffice Unventilated 3 0.1 0.85 No No Attic Entry/Kitchen/Dining Attic RoofEntry/Kitchen/Dini ng Unventilated 3 0.1 0.85 No No Attic Great Room Attic RoofGreat Room Unventilated 3 0.1 0.85 No No Attic Bedroom 2 Attic RoofBedroom 2 Unventilated 3 0.1 0.85 No No Attic Rec/Media Attic RoofRec/Media Unventilated 3 0.1 0.85 No No Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 8 of 24) ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Bedroom 3/1-aundry Attic RoofBedroom 3/1-aundry Unventilated 3 0.1 0.85 No No Attic Guest House Attic RoofGuest House Unventilated 3 0.1 0.85 No No Attic Bedroom 4 Attic RoofBedroom 4 Unventilated 3 0.1 0.85 No No Attic Bedroom 5 Attic RoofBedroom 5 Unventilated 3 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading 4 Window N Wall 0 4.5 11 1 49.5 0.3 NFRC 0.2 NFRC Bug Screen E Window N Wall 0 2.5 5 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen F Window N Wall 0 6 11 1 66 0.3 NFRC 0.2 NFRC Bug Screen E 2 Window N Wall 0 2.5 5 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen D Window E Wall 90 1 25 0.3 NFRC 0.2 NFRC Bug Screen 6 Window W Wall 270 16 11 1 176 0.36 NFRC 0.22 NFRC Bug Screen C Window N Wall 2 0 1 66 0.3 NFRC 0.2 NFRC Bug Screen B Window N Wall 2 0 1 12 0.3 NFRC 0.2 NFRC Bug Screen A Window N Wall 2 0 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen 2 Window E Wall 2 90 12 10 1 132 0.36 NFRC 0.22 NFRC Bug Screen 1 Window E Wall 3 90 28 11 1 308.9 0.36 NFRC 0.22 NFRC Bug Screen R Window E Wall 3 90 1 294 0.3 NFRC 0.2 NFRC Bug Screen L Window S Wall 2 180 6 11 1 66 0.3 NFRC 0.2 NFRC Bug Screen K Window S Wall 2 180 3 5 1 15 0.3 NFRC 0.2 NFRC Bug Screen 7 Window W Wall 3 270 42 11 1 462 0.36 NFRC 0.22 NFRC Bug Screen W Window W Wall 3 270 1 336 0.3 NFRC 0.2 NFRC Bug Screen Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 9 of 24) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading J Window S Wall 3 180 2.5 5 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen I Window S Wall 3 180 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen H Window S Wall 3 180 113 6 0 33.22 0.3 NFRC 0.2 NFRC Bug Screen G Window S Wall 3 180 2.5 5 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen 8 Window W Wall 4 270 16 11 1 176 0.36 NFRC 0.22 NFRC Bug Screen 16 Window N Wall 4 0 20 11 1 220 0.36 NFRC 0.22 NFRC Bug Screen Q Window N Wall 5 0 4 5 1 20 0.36 NFRC 0.22 NFRC Bug Screen 10 Window S Wall 5 180 12 8 1 96 0.36 NFRC 0.22 NFRC Bug Screen M Window S Wall 5 180 2.5 5 1 12.5 0.36 NFRC 0.22 NFRC Bug Screen GB Window N Wall 6 0 1 55 0.3 NFRC 0.2 NFRC Bug Screen GC Window N Wall 6 0 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen GD Window N Wall 6 0 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen G5 Window E Wall 7 90 1 80 0.36 NFRC 0.22 NFRC Bug Screen G6 Window E Wall 7 90 1 80 0.3 NFRC 0.2 NFRC Bug Screen GA Window S Wall 6 180 2.5 5 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen G1 Window S Wall 6 180 3 8 1 24 0.36 NFRC 0.22 NFRC Bug Screen G2 Window S Wall 6 180 6 11 1 66 0.36 NFRC 0.22 NFRC Bug Screen G3 Window W Wall 7 270 11.5 11 1 126.5 0.36 NFRC 0.22 NFRC Bug Screen G4 Window W Wall 7 270 12 11 1 132 0.3 NFRC 0.2 NFRC Bug Screen V Window N Wall 7 0 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen U Window N Wall 7 0 1 72 0.3 NFRC 0.2 NFRC Bug Screen S Window N Wall 7 0 1 48 0.3 NFRC 0.2 NFRC Bug Screen T Window E Wall 8 90 1 10 0.3 NFRC 0.2 NFRC Bug Screen 17 Window W Wall 8 270 1 144 0.36 NFRC 0.22 NFRC Bug Screen CC Window E Wall 9 90 1 10 0.3 NFRC 0.2 NFRC Bug Screen Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 10 of 24) FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ftz) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Z Window E Wall 9 90 1 10 0.3 NFRC 0.2 NFRC Bug Screen BB Window S Wall 7 180 1 10 0.3 NFRC 0.2 NFRC Bug Screen AA Window S Wall 7 180 1 48 0.3 NFRC 0.2 NFRC Bug Screen y Window S Wall 7 180 1 14 0.3 NFRC 0.2 NFRC Bug Screen X Window S Wall 7 180 1 48 0.3 NFRC 0.2 NFRC Bug Screen 18 Window W Wall 9 270 1 144 0.36 NFRC 0.22 NFRC Bug Screen Skylight Skylight Roof 270 1 0.8 0.3 NFRC 0.3 NFRC None Skylight 2 Skylight Roof 270 1 0.8 0.3 NFRC 0.3 NFRC None Skylight 3 Skylight Roof 270 1 0.8 0.3 NFRC 0.3 NFRC None Skylight 4 Skylight Roof 270 1 0.8 0.3 NFRC 0.3 NFRC None Skylight 5 Skylight Roof 270 1 0.8 0.3 NFRC 0.3 NFRC None OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 4 3 0.1 3 0 0 0 0 0 0 0 0 0 0 E 3 0.1 3 0 0 0 0 0 0 0 0 0 0 F 8 0.1 8 8 0 0 0 0 0 0 0 0 0 E2 6 0.1 6 6 0 0 0 0 0 0 0 0 0 6 12 0.1 12 12 0 0 0 0 0 0 0 0 0 2 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 11 of 24) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 L 6 0.1 6 6 0 0 0 0 0 0 0 0 0 K 6 0.1 6 6 0 0 0 0 0 0 0 0 0 7 18 0.1 18 18 0 0 0 0 0 0 0 0 0 J 3 0.1 3 0 0 0 0 0 0 0 0 0 0 H 3 0.1 3 0 0 0 0 0 0 0 0 0 0 G 3 0.1 3 0 0 0 0 0 0 0 0 0 0 8 6 0.1 6 6 0 0 0 0 0 0 0 0 0 16 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Q 4 0.1 4 4 0 0 0 0 0 0 0 0 0 10 3 0.1 3 0 0 0 0 0 0 0 0 0 0 M 3 0.1 3 0 0 0 0 0 0 0 0 0 0 GA 8 0.1 8 8 0 0 0 0 0 0 0 0 0 G1 8 0.1 8 8 0 0 0 0 0 0 0 0 0 G2 3 0.1 3 0 0 0 0 0 0 0 0 0 0 G3 3 0.1 3 0 0 0 0 0 0 0 0 0 0 G4 3 0.1 3 0 0 0 0 0 0 0 0 0 0 Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 12 of 24) SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab Bedroom 1 1990 118 none 0 80% No Slab 2 Office 1021 65 none 0 80% No Slab 3 Entry/Kitchen/Dining 2093 118 none 0 80% No Slab 4 Great Room 1581 118 none 0 80% No Slab 5 Bedroom 2 1623 102 none 0 80% No Slab 6 Rec/Media 1844 72 none 0 80% No Slab 7 Bedroom 3/1-aundry 985 98 none 0 80% No Slab 8 Guest House 2228 204 none 0 80% No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood R-38 + R-191 Cathedral Ceilings Wood Framed 2x6 @ 16 in. 0. C. R-38 R-19 / None 0.019 Siding/sheathing/decking Ceiling Cavity / Frame: R-38 / 2x6 Sheathing / Insulation: R-19 Sheathing Inside Finish: Gypsum Board Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 13 of 24) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C. R-0 None / None 0.277 Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofBedroom 1 Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofOffice Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Attic Wood Framed Roof Deck: Wood RoofEntry/Kitchen/Dini Attic Roofs 2x4 @ 24 in. O. C. R-19 None / None 0.059 Siding/sheathing/decking ng Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofGreat Room Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofBedroom 2 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 14 of 24) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofRec/Media Attic Roofs 2x4 @ 24 in. O. C. R-19 None / None 0.059 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Attic RoofBedroom Wood Framed Roof Deck: Wood 3/Laundry Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofGuest House Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofBedroom 4 Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofBedroom 5 Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.059 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Floor Surface: Carpeted Floors Over Floor Deck: Wood R-19 Floor Crawlspace Wood Framed Floor 2x6 @ 16 in. 0. C. R-19 None / None 0.05 Siding/sheathing/decking Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6 Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 15 of 24) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Ceilings (below Wood Framed Over Ceiling Joists: R-23.7 insul. R-38 + R-19 attic) Ceiling 2x6 @ 16 in. O. C. R-38 None / None 0.026 Cavity / Frame: R-14.3 / 2x6 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water Standard Distribution DHW Heater 1 (3) n/a None n/a (DHW) System DHW Sys 3 Domestic Hot Water Standard Distribution DHW Heater 3 (1) n/a None n/a (DHW) System WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Heating Tank Energy Tank Standby Loss # of Input Rating Insulation 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Units Vol. Factor or or Pilot R-value or Recovery or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff DHW Heater 1 Gas Consumer 3 0 0.98-UEF <= 200 0 n/a n/a n/a n/a Instantaneous kBtu/hr Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 16 of 24) WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Tank Heating # of Tank Energy Input Rating Insulation Standby Loss 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Units Vol. Factor or or Pilot R-value or Recovery or Flow Rate Brand or Model Ambient Condition Type (gal) Efficiency (Int/Ext) Eff DHW Heater 3 Gas Consumer 1 0 0.98-UEF <= 200 0 n/a n/a n/a n/a Instantaneous kBtu/hr WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 1/3 Not Required Not Required Not Required None Not Required Not Required Not Required DHW Sys 3 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count Heat Pump Heat Pump Air AC 11 Heat pump heating cooling HVAC Fan 1 Distribution Setback New NA 1 1 System 1 System 1 System 1 Air AC 22 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 2 Distribution Setback New NA 1 1 System 2 System 2 System 2 Heat Pump Heat Pump Air AC 33 Heat pump heating cooling HVAC Fan 3 Distribution Setback New NA 1 1 System 3 System 3 System 3 Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 17 of 24) SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Required Verified Heating Cooling Name System Type Heating Unit Cooling Unit Fan Name Distribution Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count Heat Pump Heat Pump Air AC 44 Heat pump heating cooling HVAC Fan 4 Distribution Setback New NA 1 1 System 4 System 4 System 4 Heat Pump Heat Pump Air AC 55 Heat pump heating cooling HVAC Fan 5 Distribution Setback New NA 1 1 System 5 System 5 System 5 Air AC 66 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 6 Distribution Setback New NA 1 1 System 6 System 6 System 6 Air AC 77 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 7 Distribution Setback New NA 1 1 System 7 System 7 System 7 Air AC 8 & 98 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 8 Distribution Setback New NA 2 2 System 8 System 8 System 8 Heat Pump Heat Pump Air AC 10 & 119 Heat pump heating cooling HVAC Fan 9 Distribution Setback New NA 2 2 System 9 System 9 System 9 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Central split HP 1 10 58000 37700 18 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 18 of 24) 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 2 Central split HP 1 10 36000 23400 18 12.5 Not Zonal Single Heat Pump System Speed 2-hers-htpump Heat Pump System 3 Central split HP 1 10 58000 37700 18 12.5 Not Zonal Single Heat Pump System Speed 3-hers-htpump Heat Pump System 4 Central split HP 1 10 58000 37700 18 12.5 Not Zonal Single Heat Pump System Speed 4-hers-htpump Heat Pump System 5 Central split HP 1 10 58000 37700 18 12.5 Not Zonal Single Heat Pump System Speed 5-hers-htpump Heat Pump System 6 Central split HP 1 10 58000 37700 18 12.5 Not Zonal Single Heat Pump System Speed 6-hers-htpump Heat Pump System 7 Central split HP 1 10 58000 37700 18 12.5 Not Zonal Single Heat Pump System Speed 7-hers-htpump Heat Pump System 8 Central split HP 2 10 36000 23400 18 12.5 Not Zonal Single Heat Pump System Speed 8-hers-htpump Heat Pump System 9 Central split HP 2 10 36000 23400 18 12.5 Not Zonal Single Heat Pump System Speed 9-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 2-hers-htpump Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 19 of 24) HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 4-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 5-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 6-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 7-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 8-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 9-hers-htpump HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Leakage HERS Verification Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 1 space -entirely ned Zone ned Zone System Duct 1-hers-d ist Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 2 space -entirely ned Zone ned Zone System Duct 2-hers-dist Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 20 of 24) HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return BypasDucts Duct Leakage HERS Verification Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 3 space -entirely ned Zone ned Zone System Duct 3-hers-dist Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 4 space -entirely ned Zone ned Zone System Duct 4-hers-dirt Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 5 space -entirely ned Zone ned Zone System Duct 5-hers-dist Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 6 space -entirely ned Zone ned Zone System Duct 6-hers-dist Air Air Distribution Conditioned Conditio Conditio No Distribution Non -Verified R-8 R-8 n/a n/a Bypass System 7 space -entirely ned Zone ned Zone System Duct 7-hers-dirt Air Air Distribution Conditioned Conditio Conditio NO Distribution Non Verified R 8 R 8 n/a n/a Bypass System 8 space -entirely ned Zone ned Zone System Duct 8-hers-dist Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 9 System Duct 9-hers-dist Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 21 of 24) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design Ducts Handler Conditioned Space Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 1-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 2-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 3-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 4-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 5-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 6-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 7-hers-dist Air Distribution Yes 6.0 Required Not Required Not Required Credit not taken Required No System 8-hers-dist Air Distribution Yes 6.0 Not Required Not Required Not Required Credit not taken Required No System 9-hers-dist Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 22 of 24) HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.45 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.45 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.45 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.45 HVAC Fan 5-hers-fan HVAC Fan 6 HVAC Fan 0.45 HVAC Fan 6-hers-fan HVAC Fan 7 HVAC Fan 0.45 HVAC Fan 7-hers-fan HVAC Fan 8 HVAC Fan 0.45 HVAC Fan 8-hers-fan HVAC Fan 9 HVAC Fan 0.45 HVAC Fan 9-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 HVAC Fan 2-hers-fan Required 0.45 HVAC Fan 3-hers-fan Required 0.45 HVAC Fan 4-hers-fan Required 0.45 HVAC Fan 5-hers-fan Required 0.45 HVAC Fan 6-hers-fan Required 0.45 HVAC Fan 7-hers-fan Required 0.45 HVAC Fan 8-hers-fan Required 0.45 HVAC Fan 9-hers-fan Required 0.45 Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 23 of 24) IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 07 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness - SIRE IAQ RecoveryHERS Effectiveness - ASRE Verification SFam IAQVentRpt 501 0.35 Exhaust n/a n/a Yes Registration Number: 222-P010053098A-000-000-0000000-0000 CaICERTS, Inc. Registration Date/Time: HERS Provider: 2022-03-21 10.11.09 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Madison Lot 39A Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-03-21T09:56:40-07:00 Input File Name: Madison Lot 39A-Radford-21.ribdl9x CF1R-PRF-01E (Page 24 of 24) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Teti-�ce�Ti Company: Signature Date: Scott Design and Title 24, Inc. 2022-03-21 10:11:09 Address: CEA/ HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: 7om'-57cozr Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2022-03-21 10:11:09 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 222-P010053098A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-03-21 10:11:09 Easy to Verify at CaICERTS.com CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-03-21 10:00:24 Schema Version: rev 20200901 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 1 of 10) GENERAL INFORMATION Energy Standards Code Year: 2019 Project Name: Madison Lot 39A ■ Project Type: New Construction SFR ■ ■ ■ Address: 53821 Ross Ave, ■ ■ City/State/Zip: La Quinta / CA / 92253 � ■ Enforcement Agency: City of La Quinta ■ Permit Number: On Site Easy to Verify @ calcerts.com OVERALL STATUS COMPLETE HERS VERIFIABLE MEASURES: COMPLETE CF1R INFORMATION - Certificate of Compliance (Document Lists Required Energy Features) Certificate Type Compliance Registered Form CF1 R-PRF-01 Registered Date 2024-03-05 08:51:49 Registration Number 224-P010028869A-000-000-0000000-0000 CF2R INFORMATION - Certificate of Installation (Documents the proper installation of required energy features) V/ System Form Registered Date Registration Number CF2R-ENV-01-E 224-P010028869A-000-001-E01001 B-0000 2024-03-06 07:23:10 Richard Doan V/ Fenestration Installation (DOAN RICHARD CONSTRUCTION) CF2R-ENV-03-E 224-P010028869A-000-001-E03001 B-0000 Insulation Installation 2024-03-06 07:23:10 Richard Doan V/ (DOAN RICHARD CONSTRUCTION) CF2R-ENV-21-H 224-P010028869A-000-001-E21001 B-0000 QII-Framing Stage 2024-03-06 07:23:10 Richard Doan V/ (DOAN RICHARD CONSTRUCTION) CF2R-ENV-22-H 224-P010028869A-000-001-E22001 B-0000 QII-Insulation Installation 2024-03-06 07:23:10 Richard Doan V/ (DOAN RICHARD CONSTRUCTION) CF2R-LTG-01-E 224-P010028869A-000-001-L01001 B-0000 2024-03-06 07:23:10 Richard Doan Lighting (DOAN RICHARD CONSTRUCTION) CF2R-MCH-01-E 224-P010028869A-000-001-M01001 B-0000 Space Conditioning 2024-03-06 07:23:11 Richard Doan Systems, Ducts and Fans (DOAN RICHARD CONSTRUCTION) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 2 of 10) System 1: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20001B-0000 1 Duct Leakage 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 2: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20002B-0000 2024-03-06 07:23:11 Richard Doan 2 Duct Leakage (DOAN RICHARD CONSTRUCTION) System 3: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20003B-0000 3 Duct Leakage 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 4: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20004B-0000 2024-03-06 07:23:11 Richard Doan 4 Duct Leakage (DOAN RICHARD CONSTRUCTION) System 5: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20005B-0000 5 Duct Leakage 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 6: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20006B-0000 2024-03-06 07:23:11 Richard Doan 6 Duct Leakage (DOAN RICHARD CONSTRUCTION) System 7: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20007B-0000 7 Duct Leakage 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 8: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20008B-0000 2024-03-06 07:23:11 Richard Doan 8 Duct Leakage (DOAN RICHARD CONSTRUCTION) System 9: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20009B-0000 9 Duct Leakage 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 10: Location CF2R-MCH-20-H 224-P010028869A-000-001-M20010B-0000 2024-03-06 07:23:11 Richard Doan 10 Duct Leakage (DOAN RICHARD CONSTRUCTION) System 1: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21001B-0000 1 Ducts Located In 2024-03-06 07:23:11 Richard Doan V/ Conditioned Space (DOAN RICHARD CONSTRUCTION) System 2: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21002B-0000 Ducts Located In 2024-03-06 07:23:11 Richard Doan 2 Conditioned Space (DOAN RICHARD CONSTRUCTION) System 3: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21003B-0000 3 Ducts Located In 2024-03-06 07:23:11 Richard Doan Conditioned Space (DOAN RICHARD CONSTRUCTION) System 4: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21004B-0000 Ducts Located In 2024-03-06 07:23:11 Richard Doan 4 Conditioned Space (DOAN RICHARD CONSTRUCTION) System 5: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21005B-0000 Ducts Located In 2024-03-06 07:23:11 Richard Doan 5 Conditioned Space (DOAN RICHARD CONSTRUCTION) System 6: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21006B-0000 Ducts Located In 2024-03-06 07:23:11 Richard Doan 6 Conditioned Space (DOAN RICHARD CONSTRUCTION) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 3 of 10) System 7: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21007B-0000 Ducts Located In 2024-03-06 07:23:11 Richard Doan 7 Conditioned Space (DOAN RICHARD CONSTRUCTION) System 8: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21008B-0000 Ducts Located In 2024-03-06 07:23:11 Richard Doan 8 Conditioned Space (DOAN RICHARD CONSTRUCTION) System 9: Location CF2R-MCH-21-H 224-P010028869A-000-001-M21009B-0000 9 Ducts Located In 2024-03-06 07:23:11 Richard Doan Conditioned Space (DOAN RICHARD CONSTRUCTION) System 1: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23001B-0000 1 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 2: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23002B-0000 2 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 3: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23003B-0000 3 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 4: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23004B-0000 4 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 5: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23005B-0000 5 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 6: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23006B-0000 6 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 7: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23007B-0000 7 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 8: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23008B-0000 8 Airflow 2024-03-06 07:23:11 Richard Doan (DOAN RICHARD CONSTRUCTION) System 9: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23009B-0000 9 Airflow 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 10: Location CF2R-MCH-23-H 224-P010028869A-000-001-M23010B-0000 10 Airflow 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 1: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22001B-0000 1 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 2: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22002B-0000 2 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 3: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22003B-0000 3 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 4 of 10) System 4: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22004B-0000 4 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 5: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22005B-0000 5 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 6: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22006B-0000 6 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 7: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22007B-0000 7 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 8: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22008B-0000 8 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 9: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22009B-0000 9 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) System 10: Location CF2R-MCH-22-H 224-P010028869A-000-001-M22010B-0000 10 Fan Efficacy 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25001 A-0000 System 1 Refrigerant Charge 2024-03-07 07:13:07 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25002A-0000 System 2 Refrigerant Charge 2024-03-07 07:15:01 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25003A-0000 System 3 Refrigerant Charge 2024-03-07 07:16:03 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25004A-0000 System 4 Refrigerant Charge 2024-03-07 07:17:05 Richard Doan V/ (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25005A-0000 System 5 Refrigerant Charge 2024-03-07 07:19:11 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25006A-0000 System 6 Refrigerant Charge 2024-03-07 07:20:01 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25007A-0000 System 7 Refrigerant Charge 2024-03-07 07:20:49 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25008A-0000 System 8 Refrigerant Charge 2024-03-07 07:22:14 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25009A-0000 System 9 Refrigerant Charge 2024-03-07 07:23:04 Richard Doan (DOAN RICHARD CONSTRUCTION) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 5 of 10) CF2R-MCH-25-H 224-P010028869A-000-001-M25010A-0000 System 10 Refrigerant Charge 2024-03-07 07:23:47 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-25-H 224-P010028869A-000-001-M25011 A-0000 System 11 Refrigerant Charge 2024-03-07 07:24:56 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26001 B-0000 System 1 Rated Equipment 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26002B-0000 System 2 2024-03-06 07:23:12 Richard Doan Rated Equipment (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26003B-0000 System 3 Rated Equipment 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26004B-0000 System 4 2024-03-06 07:23:12 Richard Doan Rated Equipment (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26005B-0000 System 5 Rated Equipment 2024-03-06 07:23:12 Richard Doan V/ (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26006B-0000 System 6 2024-03-06 07:23:12 Richard Doan Rated Equipment (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26007B-0000 System 7 Rated Equipment 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26008B-0000 System 8 2024-03-06 07:23:12 Richard Doan Rated Equipment (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26009B-0000 System 9 Rated Equipment 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26010B-0000 System 10 2024-03-06 07:23:12 Richard Doan V/ Rated Equipment (DOAN RICHARD CONSTRUCTION) CF2R-MCH-26-H 224-P010028869A-000-001-M26011 13-0000 System 11 Rated Equipment 2024-03-06 07:23:12 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-MCH-27-H 224-P010028869A-000-001-M27001 A-0000 IAQ and MV 2024-03-07 07:25:47 Richard Doan V/ (DOAN RICHARD CONSTRUCTION) CF2R-PLB-02-E 224-P010028869A-000-001-B02001 A-0000 SD HWS Distribution 2024-03-07 07:26:26 Richard Doan (DOAN RICHARD CONSTRUCTION) CF2R-PVB-01-E 224-P010028869A-000-001-V01001 A-0000 Photovoltaic Systems 2024-03-07 07:26:39 Richard Doan (DOAN RICHARD CONSTRUCTION) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 6 of 10) CF3R INFORMATION - Certificate of Verification (Documents the verification of HERS Measures) V/ System Form Registered Date Registration Number CF3R-ENV-21-H 224-P010028869A-000-001-E21001 B-E21 A (QII-Framing Stage) 2024-03-06 07:23:30 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-ENV-22-H 224-P010028869A-000-001-E22001 B-E22A (QII-Insulation Installation) 2024-03-06 07:23:37 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 1: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20001B-M20A 1 (Duct Leakage) 2024-03-06 07:24:13 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 2: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20002B-M20A 2 (Duct Leakage) 2024-03-06 07:24:23 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 3: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20003B-M20A 3 (Duct Leakage) 2024-03-06 07:24:32 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 4: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20004B-M20A 4 (Duct Leakage) 2024-03-06 07:24:42 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 5: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20005B-M20A 5 (Duct Leakage) 2024-03-06 07:24:54 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 6: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20006B-M20A 6 (Duct Leakage) 2024-03-06 07:25:03 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 7: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20007B-M20A 7 (Duct Leakage) 2024-03-06 07:25:13 Ryan Bailey (CC2006116) %/ (Eco Green Energy Solutions) System 8: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20008B-M20A 8 (Duct Leakage) 2024-03-06 07:25:30 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 9: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20009B-M20A 9 (Duct Leakage) 2024-03-06 07:25:40 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 10: Location CF3R-MCH-20-H 224-P010028869A-000-001-M20010B-M20A 10 (Duct Leakage) 2024-03-06 07:25:48 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 1: Location CF3R-MCH-21-H 224-P010028869A-000-001-M21001B-M21A 1 (Ducts In Cond Space) 2024-03-06 07:25:54 Ryan Bailey (CC2006116) %/ (Eco Green Energy Solutions) System 2: Location CF3R-MCH-21-H 224-P010028869A-000-001-M21002B-M21A 2 (Ducts In Cond Space) 2024-03-06 07:25:59 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 3: Location CF3R-MCH-21-H 224-P010028869A-000-001-M21003B-M21A 3 (Ducts In Cond Space) 2024-03-06 07:26:04 Ryan Bailey (CC2006116) %/ (Eco Green Energy Solutions) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CalCERTS, Inc Effective 03/07/2024 07:37 (Page 7 of 10) System 4: Location CHR-MCH-21-1-1 224-P010028869A-000-001-M21004B-M21A 4 (Ducts In Cond Space) 2024-03-06 07:26:10 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 5: Location MR-MCH-21-1-1 224-P010028869A-000-001-M21005B-M21A 5 (Ducts In Cond Space) 2024-03-06 07:26:15 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 6: Location CHR-MCH-21-1-1 224-P010028869A-000-001-M21006B-M21A 6 (Ducts In Cond Space) 2024-03-06 07:26:22 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 7: Location MR-MCH-21-1-1 224-P010028869A-000-001-M21007B-M21A 7 (Ducts In Cond Space) 2024-03-06 07:26:28 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 8: Location CF3R-MCH-21-H 224-P010028869A-000-001-M21008B-M21A 8 (Ducts In Cond Space) 2024-03-06 07:26:33 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 9: Location MR-MCH-21-1-1 224-P010028869A-000-001-M21009B-M21A 9 (Ducts In Cond Space) 2024-03-06 07:26:38 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 1: Location CF3R-MCH-23-H 224-P010028869A-000-001-M23001B-M23A 1 (Airflow) 2024-03-06 07:26:50 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 2: Location CHR-MCH-23-1-1 224-P010028869A-000-001-M23002B-M23A 2 (Airflow) 2024-03-06 07:26:59 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 3: Location CHR-MCH-23-1-1 2024-03-06 07:27:08 224-P010028869A-000-001-M23003B-M23A Ryan Bailey (CC2006116) 3 (Airflow) (Eco Green Energy Solutions) System 4: Location MR-MCH-23-1-1 224-P010028869A-000-001-M23004B-M23A 4 (Airflow) 2024-03-06 07:27:20 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 5: Location MR-MCH-23-1-1 2024-03-06 07:27:29 224-P010028869A-000-001-M23005B-M23A Ryan Bailey 5 (Airflow) (CC2006116) (Eco Green Energy Solutions) System 6: Location CHR-MCH-23-1-1 224-P010028869A-000-001-M23006B-M23A 6 (Airflow) 2024-03-06 07:27:37 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 7: Location MR-MCH-23-1-1 224-P010028869A-000-001-M23007B-M23A 7 (Airflow) 2024-03-06 07:27:45 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 8: Location CHR-MCH-23-1-1 224-P010028869A-000-001-M23008B-M23A 8 (Airflow) 2024-03-06 07:27:52 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 9: Location MR-MCH-23-1-1 2024-03-06 07:30:18 224-P010028869A-000-001-M23009B-M23A Ryan Bailey 9 (Airflow) (CC2006116) (Eco Green Energy Solutions) System 10: Location CHR-MCH-23-1-1 224-P010028869A-000-001-M23010B-M23A 10 (Airflow) 2024-03-06 07:30:27 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CalCERTS, Inc Effective 03/07/2024 07:37 (Page 8 of 10) System 1: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22001B-M22A 1 (Fan Efficacy) 2024-03-06 07:30:33 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 2: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22002B-M22A 2 (Fan Efficacy) 2024-03-06 07:30:39 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 3: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22003B-M22A 3 (Fan Efficacy) 2024-03-06 07:30:46 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 4: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22004B-M22A 4 (Fan Efficacy) 2024-03-06 07:30:54 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 5: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22005B-M22A 5 (Fan Efficacy) 2024-03-06 07:31:01 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 6: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22006B-M22A 6 (Fan Efficacy) 2024-03-06 07:31:08 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 7: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22007B-M22A 7 (Fan Efficacy) 2024-03-06 07:31:15 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 8: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22008B-M22A 8 (Fan Efficacy) 2024-03-06 07:31:21 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) System 9: Location CF3R-MCH-22-H 2024-03-06 07:31:28 224-P010028869A-000-001-M22009B-M22A Ryan Bailey (CC2006116) 9 (Fan Efficacy) (Eco Green Energy Solutions) System 10: Location CF3R-MCH-22-H 224-P010028869A-000-001-M22010B-M22A 10 (Fan Efficacy) 2024-03-06 07:31:35 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25001 A-M25A System 1 (Refrigerant Charge) 2024-03-07 07:27:21 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25002A-M25A System 2 (Refrigerant Charge) 2024-03-07 07:27:35 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25003A-M25A System 3 (Refrigerant Charge) 2024-03-07 07:27:45 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25004A-M25A System 4 (Refrigerant Charge) 2024-03-07 07:27:56 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25005A-M25A System 5 (Refrigerant Charge) 2024-03-07 07:28:13 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25006A-M25A System 6 (Refrigerant Charge) 2024-03-07 07:28:22 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CalCERTS, Inc Effective 03/07/2024 07:37 (Page 9 of 10) CF3R-MCH-25-H 224-P010028869A-000-001-M25007A-M25A System 7 (Refrigerant Charge) 2024-03-07 07:28:33 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25008A-M25A System 8 (Refrigerant Charge) 2024-03-07 07:28:42 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25009A-M25A System 9 (Refrigerant Charge) 2024-03-07 07:28:57 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25010A-M25A System 10 (Refrigerant Charge) 2024-03-07 07:29:06 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-25-H 224-P010028869A-000-001-M25011 A-M25A System 11 (Refrigerant Charge) 2024-03-07 07:35:54 Ryan Bailey (CC2006116) V/ (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26001 B-M26A System 1 (Rated Equipment) 2024-03-06 07:31:51 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26002B-M26A System 2 (Rated Equipment) 2024-03-06 07:34:55 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26003B-M26A System 3 (Rated Equipment) 2024-03-06 07:35:08 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26004B-M26A System 4 (Rated Equipment) 2024-03-06 07:35:21 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26005B-M26A System 5 (Rated Equipment) 2024-03-06 07:35:50 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26006B-M26A System 6 (Rated Equipment) 2024-03-06 07:36:09 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26007B-M26A System 7 (Rated Equipment) 2024-03-06 07:36:26 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26008B-M26A System 8 (Rated Equipment) 2024-03-06 07:36:51 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26009B-M26A System 9 (Rated Equipment) 2024-03-06 07:37:07 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26010B-M26A System 10 (Rated Equipment) 2024-03-06 07:37:25 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) CF3R-MCH-26-H 224-P010028869A-000-001-M26011 B-M26A System 11 (Rated Equipment) 2024-03-06 07:37:52 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019 PROJECT STATUS REPORT CaICERTS, Inc Effective 03/07/2024 07:37 (Page 10 of 10) CHR-MCH-27-H 224-P010028869A-000-001-M27001 A-M27A (IAQ and MV) 2024-03-07 07:35:38 Ryan Bailey (CC2006116) (Eco Green Energy Solutions) HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards 2019 Residential Compliance Dec 2019