Loading...
Andalusia TR 31681 BCPR2023-0008PLAN SNAPSHOT REPORT BCPR2023-0008 FOR CITY OF LA QUINTA Building Construction Plan Review 05/09/2023App Date:Plan No.:Plan Type:BCPR2023-0008 City of La QuintaBuilding Construction Plan Review 05/08/2024Exp Date:District:Work Class: 0.00Expired NOT COMPLETEDCompleted:Square Feet:Status: Description: Valuation: ANDALUSIA DEVELOPMENT / CONSTRUCTION MASTER PLANS FOR PLANS 401 & 402. CODE UPDATE FOR THE 2022 CODE CYCLE. PLAN 401: 4,426SF PLAN 402: 4,426SF REVISION 1 - PLAN 401 AND 402 ENERGY UPDATED TO REFLECT INCREASED SOLAR PV SYSTEM SIZE, DECREASED ESS SIZE, ALTERNATE CFI, UPDATED FENESTRATION VALUES, AND REVISED HERS FEATURES. 2022 CALIFORNIA BUILDING CODES. $0.00 Assigned To:Approval Expire Date:NOT AVAILABLE Parcel:Main764620041 Address:Andalusia - Plan 401 & 402 Main Zone: Contractor Nolan Sparks 81570 Carboneras La Quinta, CA 92253 Applicant Nolan Sparks 81570 Carboneras La Quinta, CA 92253 Plan Custom Fields Tract / Subdivision Name ANDALUSIA Tract Number 31681 Number of Plan Types SFDX2 Code Edition 2022 Is this a revision?No General Plan ROW City Limits Within La Quinta City Limits Acreage 3.83 Subdivision Name TR 31681-2 Lot Number S Legal Description Lot S MB 397/34 TR 31681-2 Centerlines 92341, 96267, 96417, 96877, 92339, 96866, 96415, 113092, 96268, 96124, 96878, 96418, 96125, 96126, 96416, 96269, 96879, 92340 Lot Size 22528.3 Attachment File Name Added On Added By Attachment Group Notes BCPR2023-0008 - 2ND REVIEW - COMPLETE CORRECTION LIST.pdf 09/29/2023 15:43 Clayton, Duane Available Online 2ND REVIEW CORRECTION LIST BCPR2023-0008 - APPROVED PLAN SET 401 S.pdf 10/23/2023 15:54 Clayton, Duane Available Online APPROVED PLAN 401 BCPR2023-0008 - APPROVED PLAN SET 402 S.pdf 10/23/2023 15:54 Clayton, Duane Available Online APPROVED PLAN 402 BCPR2023-0008 Fire COA.pdf 10/30/2023 10:47 Cox, Chris Available Online NOT A PLAN SET OR REVISION.pdf 05/13/2024 10:32 Molina, Elizabeth Internal Only Construction Plan Set BCPR2023-0008 TRUSS CALCULATIONS (APPROVED)_v1.pdf 05/29/2024 11:54 Molina, Elizabeth Available Online Truss Calculations REV 1 - ENERGY REPORT PLAN 401 (APPROVED)_v1.pdf 09/11/2024 8:14 Molina, Elizabeth Available Online Energy Documents REV 1 - ENERGY REPORT PLAN 402 (APPROVED)_v1.pdf 09/11/2024 8:14 Molina, Elizabeth Available Online Energy Documents Page 1 of 378-495 Calle TampicoApril 25, 2025 PLAN SNAPSHOT REPORT (BCPR2023-0008) Invoice No.Amount PaidFeeFee Amount INV-00001984 $175.00 Hourly Charge - City Building Staff $175.00 $175.00 Hourly Charge - City Building Staff $175.00 $187.50 Hourly Charge - Interwest Structural Plan Review $187.50 $20.16 Credit Card Convenience Fee $20.16 $175.00 Hourly Charge - City Building Staff $175.00 $93.75 Hourly Charge - Interwest Structural Plan Review $93.75 $826.41 $826.41 Total for Invoice INV-00001984 INV-00006893 $87.50 Hourly Charge - City Building Staff $87.50 $87.50 $87.50 Total for Invoice INV-00006893 INV-00009125 $175.00 Hourly Charge - City Building Staff $175.00 $4.38 Credit Card Convenience Fee $4.38 $179.38 $179.38 Total for Invoice INV-00009125 Grand Total for Plan $1,093.29 $1,093.29 UserActivity Number Name Created OnActivity Type Workflow Action Name Email ACT-000016-2023 Duane Clayton 09/29/2023 Comments: NOTIFIED APPLICANT THAT PLAN REVIEW IS COMPLETE AND PLANS REQUIRE REVISIONS. Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Major Review v.1 05/09/2023 05/31/2023 09/19/2023 Yes Yes Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Major Review v.2 08/14/2023 08/28/2023 09/29/2023 Yes Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building Building Clayton, Duane Revisions Required 09/19/2023 08/28/2023 09/20/2023 Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Fire Department - Building Cases Office of the Fire Marshal In Review 09/19/2023 08/28/2023 09/29/2023 Comments: CREATED IN TRAKIT, ONLY UPDATED IN TYLER AS OF 9/19/2023 BY AOR Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Complete Outside Agency Clayton, Duane Revisions Required 09/19/2023 08/28/2023 09/20/2023 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedBuilding Major Review v.3 10/13/2023 10/20/2023 10/30/2023 No Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building Building Clayton, Duane Approved 10/13/2023 10/20/2023 10/23/2023 Comments: PC3 IN-HOUSE PER DC Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Fire Department - Building Cases Office of the Fire Marshal Cox, Chris Approved 10/13/2023 10/27/2023 10/30/2023 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedBuilding Review v.1 05/13/2024 05/20/2024 05/29/2024 No Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1WK)Building Fuson, Jake Approved 05/13/2024 05/20/2024 05/29/2024 Comments: TRUSS REVIEW Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedBuilding Revision Review v.1 07/29/2024 08/05/2024 09/11/2024 No Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1WK)Building Clayton, Duane Approved 07/29/2024 08/05/2024 09/10/2024 Page 2 of 378-495 Calle TampicoApril 25, 2025 PLAN SNAPSHOT REPORT (BCPR2023-0008) Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 10/30/2023 11:33 Building Major Review v.1 Receive Submittal 09/19/2023 0:00 09/19/2023 9:55 Building Major Review v.2 Receive Submittal 09/19/2023 0:00 09/29/2023 15:45 Building Major Review v.3 Receive Submittal 10/13/2023 0:00 10/30/2023 11:33 Building Review v.1 Receive Submittal 05/13/2024 0:00 05/29/2024 11:54 Revisions v.1 09/11/2024 8:14 Building Revision Review v.1 Receive Submittal 07/29/2024 0:00 09/11/2024 8:14 Linked Records v.1 Linked Permits v.1 Create Sub Permit Page 3 of 378-495 Calle TampicoApril 25, 2025 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org October 30, 2023 Attn: Nolan Sparks, National Mortgage and Land Company Re: Residential Building Tract Plans – Andalusia BCPR2023-0008 The building plans you submitted for the above referenced project have been reviewed and approved by the Fire Department with the following conditions. TRACT ACCESS & WATER REQUIREMENTS: ACCESS Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with the California Fire Code, La Quinta Municipal Code and Riverside County Fire Department Standards. 1) Certain designed areas will be required to be maintained as fire lanes and will require approved signs and/or red painted curbs. 2) Vehicle access gates shall be provided with KNOX Box, Padlock or Key-switch access. Automatic gates shall also have Opticom IR receivers. 3) Approved street signs shall be installed and visible. 4) No Traffic Calming Devices shall be installed. *Future/proposed traffic calming devices require approval by the Office of the Fire Marshal. WATER 1) Fire hydrants shall be installed within 600 feet hose-lay length of the proposed residential units. 2) An observable minimum fire flow shall be present upon testing. 3) Fire hydrant caps shall be in place and marked in accordance with local requirements. 4) Blue roadway reflector shall be installed in the completed roadway to identify the location of all fire hydrants. 5) Hydrant roadway valve boxes shall have their coverplate or lid exposed and easily accessible. PRIOR TO PERMIT RELEASE INSPECTION 1) Individual Tract Home (Production) permits will not be released until a Tract Access/Water inspection has been completed for the affected phase or grouping of lots. Applicant/Contractor shall be responsible for contacting the Office of the Fire Marshal to schedule inspections. Request for inspections are to be made at least 48 hours in advance and may be arranged by calling 760-777-7131. DEFERRED SUBMITTALS REQUIRED 1) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed Contractor (C-16) shall submit plans and details for review and approval prior to Rough Inspections. a. Residential Fire Sprinkler permits may be applied for as Master Plan Types. A single Fire Sprinkler Master Plan permit for each different plan type may be individually applied for. Coordinate with the La Quinta Permit Technicians for appropriate application and fee process. GENERAL CONDITIONS 1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their background shall be posted on the structure when viewable from the roadway, or at the driveway entrance and maintained visible from both directions of travel. 2) All HOA and Private landscaping shall maintain a minum 3-feet radius clearance around the circumference of fire protection equipment, that includes fire hydrants. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078 Chris Cox – Fire Safety Supervisor DESIGN & DEVELOPMENT D EPARTMENT 78-495 C ALLE T AMPICO L A Q UINTA , C ALIFORNIA 92253 (760) 777 -7125 FAX (760) 777 -7011 Residential Plan Check Correction List Page 1 of 3 RESIDENTIAL PLAN CHECK CORRECTION LIST DATE: 9/20/2023 STATUS: SECOND REVIEW PLANS 401 & 402 PLAN CHECKED BY: DUANE CLAYTON TELEPHONE NUMBER: 760-777-7084 ADDRESS: 81570 CARBONERAS DESCRIPTION: NEW SFD APPLICANT: NAT’L MORTGAGE & LAND PLAN CHECK #: BCPR2023-0008 This submittal has been checked for compliance with the 2022 California Residential, Green Building and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for correction: 1 – 2ND SUBMITTAL PLAN SET THIS CORRECTION LIST DO NOT accept any resubmittal unless ALL of the following items are included: 1 – REVISED PLAN THIS CORRECTION LIST W/RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, “Sheet A-3,” or, “Handrails shall be per CBC Section 1003,” are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, “Added note 16 on sheet A-3” are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red-marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer’s name and telephone number and shall be wet-signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by Californi a Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Page 2 of 3 SECTION A - GENERAL 1) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 65% of the construction materials from landfill for the project. Contact the District Environmental Coordinator directly at (760) 674-1026 for free assistance with the preparation of this plan. SECTION B – PRECISE / SITE PLAN / ZONING 1) No comments remain. SECTION C - ARCHITECTURAL 1) No comments remain. SECTION D - MECHANICAL 1) No comments remain. SECTION E – ELECTRICAL 1) No comments remain. SECTION F - PLUMBING 1) No comments. SECTION G – ENERGY EFFICIENCY 1) PC-1: Provide complete energy calculations showing compliance with the 2022 California Energy Code for this project. Due to lack of information in this submittal, a comprehensive review will be performed at the next submittal. PC-2: Comment continues. Energy documents have been incorporated into the plan set, thank you. The azimuth orientation of the proposed pv array is called out at 180 degrees (South). I encourage the use of the California Flexible Installation (CFI) range, which is 150-270 degrees. This is typically the go-to option for tract construction where it is not possible to achieve one orientation of installation for all homes. 2) PC-1: Energy storage systems (ESS) ready. All single-family residences that include one or two dwelling units shall meet the following. All electrical components shall be installed in accordance with the Californ ia Electrical Code: 1. At least one of the following shall be provided: A. ESS ready interconnection equipment with a minimum backed -up capacity of 60 amps and a minimum of four ESS-supplied branch circuits, or B. A dedicated raceway from the main service to a panelboard (subpanel) that supplies the branch circuits in Section 150.0(s)(2). All branch circuits are permitted to be supplied by the main service panel prior to the installation of an ESS. The trade size of the raceway shall be not less than 1 inch. The panelboard that supplies the branch circuits (subpanel) must be labeled “Subpanel shall include all backed-up load circuits.” 2. A minimum of four branch circuits shall be identified and have their source of supply collocated at a single panelboard suitable to be supplied by the ESS. At least one circuit shall supply the refrigerator, one lighting circuit shall be located near the primary egress and at least one circuit shall supply a sleeping room receptacle outlet. 3. The main panelboard shall have a minimum busbar rating of 225 amps. 4. Sufficient space shall be reserved to allow future installation of a system isolation equipment/transfer switch within 3 feet of the main panelboard. Raceways shall be installed between the panelboard and the system isolation equipment/transfer switch location to allow the connection of backup power source. PC-2: Comment partially addressed. Note on plans verified, thank you. Please indicate on the single -line diagram a backup capacity of 60 amps minimum for the solar panel, and indicate the four required back up circuits and the panel they are to be located in. Refer to code reference above. For reference, 400 amp split main services that have both Residential Plan Check Correction List Page 3 of 3 main overcurrent devices in the same compartment are no longer permitted in the electrical code (230.71(B)). The single line only shows one throw for the panel, but I believe the services used in the past, on that tract, have been the split main type. Clarify which type of main service is being used. Please reach out with any questions regarding this new requirement. SECTION H - CALGREEN 1) No comments. SECTION I - STRUCTURAL 1) PC-1: S1. Drawing SN1: B. Please provide a code update letter from the soils engineer. C. Please provide soils engineer stamp/signature on foundation plans and details or an updated review letter from soils engineer. D. Please coordinate sheets with originally approved set of drawings. Simpson SSW detail sheets are missing. PC-2: Comment partially addressed. Item D remains from previous review. SECTION J – SOIL / FOUNDATION 1) See comment above. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. 1500 S. Haven Ave | Suite 220 Ontario, CA 91761 909.295-3142 August 25, 2023 CITY OF LA QUINTA - SECOND REVIEW Permit No: BCPR2023-0008 Interwest No.: LAQ23-0040 Non-Structural: 0.5-hours Structural: 0.25-hours City of La Quinta Building Department 78-495 Calle Tampico La Quinta, CA 92253 Plan Review: ACC 401_402 2022 Code Updates Address: 81570 Carboneras Interwest Consulting Group has completed a second code compliance review of the following documents on behalf of the City of La Quinta: 1. Drawings: Electronic copies of following: a. CS through D-6 dated 8/11/2023 by PEKAREK. b. SN1 through SSW2 dated 7/19/2023 by Gouvis. c. E-1.0 through T24.1 dated 8/8/2023 by GLS. 2. Structural Calculations: Electronic copies dated 4/5/2023 by Gouvis. 3. Energy Compliance Documentation: Electronic copies dated 8/10/2023 by GLS. 4. Geotechnical Investigation: Not provided. The applicable provisions of the 2022 California Building Standards Code were used as the basis of this review. Plan review comments follow on the attached list. Please submit an itemized response letter and complete and revised documents with directly to city of La Quinta Building and Safety Department. Sincerely, INTERWEST CONSULTING GROUP Martha Diaz, P.E. Plans Examiner mdiaz@interwestgrp.com 909.719.0249 ACC Plans (401 and 402), Code Updates City of La Quinta - Second Review 59000 Madison St. Interwest Project No.: LAQ23-0040 8/25/23 Permit App: BCPR2023-0008 Page 2 of 4 PROJECT DATA: Occupancy Group: Area (sq. ft.): (401/402) R3 4,426/5,090 U 802/827 R3 (patios) 855/1,245 Total Area: 6,083/7,162 Building Height: Varies Building Stories: 1/1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: TBD Risk Category: II Site Class (seismic): D-default Seismic Design Category: D GENERAL COMMENTS: G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following comments reference the 2022 California Building Standards Code as amended by the authority having jurisdiction unless otherwise noted. G2. Please respond in writing to each plan review comment by marking this comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the following should be included with each plan review response: • Page / sheet number(s), detail / specification number(s), etc., and include all applicable code section(s). • Briefly explain in writing how the design is intended to comply with the applicable code sections. • Please provide a narrative of revisions made outside the plan review comments. Complete and clear responses will expedite the re-check of this project. G3. Please be sure to include on the re-submittal the architect’s and /or engineer’s stamp, signature, date of signature, and registration number on all sheets of plans depicting structural designed elements and cover sheets of calculations. CBPC 5536.1 and 6735. ACC Plans (401 and 402), Code Updates City of La Quinta - Second Review 59000 Madison St. Interwest Project No.: LAQ23-0040 8/25/23 Permit App: BCPR2023-0008 Page 3 of 4 PLAN REVIEW COMMENTS: The revised permit documents have been reviewed. The following comments are numbered per the original list and require further response and/or revision. The format includes the original comment followed by a new or clarified recheck comment in bold italic typeface, prefaced by PC2. Please provide original approved drawings to verify changes only consist of code updates. All sheets will be verified during the second review. PC2. Comment remains. Unable to compare new drawings with original approved. Please provide. BUILDING AND LIFE SAFETY: A1. Drawing 401-3/402-3: No further comments 8/25/2023 MD ENERGY COMPLIANCE: Electrical Compliance: EE1. Drawings 401-3/402-3: No further comments 8/25/2023 MD EE2. Drawings 401-6/402-6: No further comments 8/25/2023 MD Mechanical Compliance: EM1. Drawing CF1R forms (both 401 and 402): No further comments 8/25/2023 MD Envelope Compliance: No comments 5/30/2023 MD CalGREEN: No comments 5/30/2023 MD ACC Plans (401 and 402), Code Updates City of La Quinta - Second Review 59000 Madison St. Interwest Project No.: LAQ23-0040 8/25/23 Permit App: BCPR2023-0008 Page 4 of 4 STRUCTURAL: S1. Drawing SN1: B. Please provide a code update letter from the soils engineer. PC2. Comment remains. C. Please provide soils engineer stamp/signature on foundation plans and details or an updated review letter from soils engineer. PC2. Comment remains. D. Please provide updated Simpson SSW detail sheets. PC2. Comment remains. Please use 2021 versions of the SSW sheets. S2. Drawing S-1.2/S-2.2: No further comments 8/25/2023 MD Please contact the listed reviewers between 9:00 A.M. and 4:00 P.M., M-F, with any questions. [END]