Loading...
Piazza Serena TR 30092 BCPR2022-0005 (Plan 1 - S852) Solar PlanRICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PV COVER PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 RE V I S I O N S RE V DE S C R I P T I O N DA T E SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 1.1 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV SR 1.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 1.1 CUTSHEETS CONT. GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS M AC P ROOF ACCESS POINTS LONGI LR4-60HPB-355M MODULES. ENPHASE ENERGY IQ7-60-2-US MICROINVERTERS, MOUNTED ON THE BACK OF EACH MODULE C SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT PV SYSTEM COMBINER PANEL UTILITY PRODUCTION METER GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH BELLA AT PIAZZA SERENA 3.1.PLAN: S852 3.2.ELEVATIONS: A, B, C 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: ENPHASE ENERGY IQ7-60-2-US 5.2.BELLA AT PIAZZA SERENA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: 5.2.1.LONGI LR4-60HPB-355M 5.3.BELLA AT PIAZZA SERENA TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.16 MODULES 5.680kW DC / 5.146kW AC 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. BCPR2022-0005 PIAZZA SERENA / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1 (S852), 2 (S853), & 3 (S850) FOR THE 2019 CODE CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING CODES. PLAN 1 (S852): 5.6kW SOLAR ARRAY - (16) 355W LONGI SOLAR LR4-60HPB-355M PANELS W/ ENPHASE IQ7-60-2-US MICROINVERTERS + 80A IQ COMBINER 3C [320SF] 05/26/2022 PLAN 1 (S852) 5.68kW SOLAR ARRAY - M C M C M C M C M C M C M C M C M C M C M C M C PV RL 1.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E PV ROOF LAYOUTS PLAN S852 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A ELEVATION: B SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" GARAGE: RIGHT GARAGE: LEFT SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC OPTION(S): NONE LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE ELEVATION: A OPTION(S): NONE GARAGE: LEFT GARAGE: LEFT GARAGE: LEFT GARAGE: LEFT GARAGE: LEFT OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE ELEVATION: B OPTION(S): NONE GARAGE: RIGHTGARAGE: RIGHTGARAGE: RIGHTGARAGE: RIGHT 05/26/2022 M C M C M C M C M C M C M C M C PV RL 1.1 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 5 LAYOUT 6 LAYOUT 7 LAYOUT 8 RE V I S I O N S RE V DE S C R I P T I O N DA T E PV ROOF LAYOUTS PLAN S852 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: C GARAGE: LEFT SCALE: 1/16" = 1'-0" GARAGE: RIGHT SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC 16 MODULES AT 5.680 kW DC OPTION(S): NONE ELEVATION: C OPTION(S): NONE ELEVATION: C OPTION(S): NONE ELEVATION: C OPTION(S): NONE ELEVATION: C OPTION(S): NONE ELEVATION: C OPTION(S): NONE ELEVATION: C OPTION(S): NONE ELEVATION: C OPTION(S): NONE GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT GARAGE: LEFT GARAGE: RIGHT 05/26/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 1 .0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 RE V I S I O N S RE V DE S C R I P T I O N DA T E *INVERTER AND DISCONNECTING MEANS TO BE INSTALLED IN GARAGE. FOR MODEL HOME(S) WITH SALES OFFICE, INVERTER AND DISCONNECTING MEANS TO BE INSTALLED OUTSIDE WITHIN SIGHT OF MSP. 05/26/2022 STRUCTURAL ENGINEERING LETTER STRUCTURAL CALCULATIONS MOUNT DETAILS PV SR 1 .0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 1 SNAPNRACK ULTRA RAIL STANDOFF BASE NOT TO SCALE 2 SNAPNRACK GROUND LUG R PRC NOT TO SCALE 4 SNAPNRACK CONDUIT MOUNT DETAIL NOT TO SCALE SHEATHING, TYP. SNAPNRACK STANDOFF BASE STD 4-HOLE, TYP SUB-FLASHING CONE, TYP FLASHING CONE, TYP TILE, TYP CONDUIT SUPPORT CONDUIT TILE HOOK TILE, TYP SHEATHING, TYP NOTE: TILE HOOK TO BE PLACED AT THE HIGH POINT OF S & W TILES SEAL PENETRATION AND BASE WITH CHEMLINK DURALINK 35 05.17.2021 FRAMING, TYP. 2-1/2"(2) 5/16" SS LAG SCREW, TYP. 3 SNAPNRACK MOUNT SPACING TYP. NOT TO SCALE CANTILEVER L/3 OR LESS LANDSCAPE: MAX 48" SPACING (L) PORTRAIT: MAX 48" SPACING (L) MODULE, TYP. FRAMING, TYP. CANTILEVER L/3 OR LESS MID CLAMP, TYP.MAX 10" - 16" CANTILEVER, TYP * MAX 10"-16" CANTILEVER, TYP * MAX 10" CANTILEVER, TYP * MAX 10" CANTILEVER, TYP * UR-60 RAIL, TYP. ENDCLAMP, TYP. *DEFER TO MODULE MANUFACTURER LIMITATIONS WHERE THEIR MAXIMUM VERTICAL CANTILEVER IS SMALLER ULTRA FOOT, TYP. SIDE VIEW BONDING CHANNEL NUT CONDUCTOR CONNECTS TO ANOTHER GROUND LUG ON BOTTOM RAIL OF ABOVE ROW OF MODULES GROUND LUG R PRC SS SPLIT LOCK WASHER GROUND CONDUCTOR UR-60 RAIL FRONT VIEW UR-60 RAIL RE V I S I O N S RE V DE S C R I P T I O N DA T E 05/26/2022 PV CS 1 .0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 RE V I S I O N S RE V DE S C R I P T I O N DA T E CUTSHEETS MICROINVERTER COMBINER PANEL MODULE AC DISCONNECT CUTSHEETS CONT. RACKING PV CS 1 .1 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-973756 HOME DEVELOPER: RICHMOND AMERICAN HOMES 391 NORTH MAIN STREET, SUITE 205 CORONA, CA 92880 BELLA AT PIAZZA SERENA LA QUINTA, CA PLAN: S852 DATE: 11/5/2021 RE V I S I O N S RE V DE S C R I P T I O N DA T E 05/26/2022