Piazza Serena TR 30092 BCPR2022-0005 (Plan 2 - S853) Solar PlanRICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PV COVER
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
SHEET INDEX:
PV COVER COVER SHEET
PV RL 2.0 PV LAYOUTS
PV RL 2.1 PV LAYOUTS CONT.
PV EE 2.0 ELECTRICAL
PV SR 2.0 STRUCTURAL
PV CS 2.0 CUTSHEETS
PV CS 2.1 CUTSHEETS CONT.
GOVERNING CODES:
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
1.2019 CA BUILDING CODE
2.2019 CA ENERGY CODE
3.2019 CA ELECTRICAL CODE
4.2019 CA FIRE CODE
5.2019 CA GREEN CODE
6.2019 CA MECHANICAL CODE
7.2019 CA PLUMBING CODE
8.2019 CA RESIDENTIAL CODE
9.ANY OTHER LOCAL AMENDMENTS
M
AC
P
ROOF ACCESS POINTS
LONGI LR4-60HPB-355M MODULES. ENPHASE ENERGY IQ7-60-2-US MICROINVERTERS,
MOUNTED ON THE BACK OF EACH MODULE
C
SYMBOLS AND ABBREVIATIONS:
MAIN SERVICE PANEL AND POINT OF INTERCONNECTION
PV SYSTEM AC DISCONNECT
PV SYSTEM COMBINER PANEL
UTILITY PRODUCTION METER
GENERAL NOTES:
1.ELECTRICAL
1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR
SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF
THE ROOF SURFACE.
1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE.
1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN
COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE.
1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS.
2.STRUCTURAL
2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY
SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE
STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD.
2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2"
PENETRATION INTO ROOF FRAMING.
2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM.
2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.
2.5.GROUND SNOW LOAD = 0 psf
2.6.WIND SPEED = 130 mph
2.7.EXPOSURE CATEGORY = C
SCOPE OF WORK
3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH BELLA AT PIAZZA
SERENA
3.1.PLAN: S853
3.2.ELEVATIONS: A, B, C
4.BUILDING INFORMATION:
4.1.BUILDING OCCUPANCY GROUP: R3/U
4.2.CONSTRUCTION TYPE: VB
5.PV
5.1.INVERTER: ENPHASE ENERGY IQ7-60-2-US
5.2.BELLA AT PIAZZA SERENA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE:
5.2.1.LONGI LR4-60HPB-355M
5.3.BELLA AT PIAZZA SERENA TO UTILIZE THE FOLLOWING SYSTEM SIZES:
5.3.1.16 MODULES 5.680kW DC / 5.146kW AC
5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV
EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT.
BCPR2022-0005
PIAZZA SERENA / SOLAR
PHOTOVOLTAIC MASTER PLANS FOR
PLANS 1 (S852), 2 (S853), & 3 (S850)
FOR THE 2019 CODE CYCLE.
INDIVIDUAL SOLAR PERMITS TO BE
ISSUED FOR EACH LOT. 2019
CALIFORNIA BUILDING CODES.
PLAN 2 (S853): 5.6kW SOLAR ARRAY -
(16) 355W LONGI SOLAR
LR4-60HPB-355M PANELS W/ ENPHASE
IQ7-60-2-US MICROINVERTERS + 80A IQ
COMBINER 3C [320SF]
05/26/2022
PLAN 2 (S853)
5.68kW SOLAR ARRAY -
M
C
M
C
M
C
M
C
M
C
M
C
M
C
M
C
PV RL 2.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN S853
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: A
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
GARAGE: LEFT
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
OPTION(S): NONE
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
GARAGE: LEFT
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: RIGHT
05/26/2022
M
C
M
C
M
C
M
C
M
C
M
C
PV RL 2.1
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
LAYOUT 1 LAYOUT 2 LAYOUT 3
LAYOUT 4 LAYOUT 5 LAYOUT 6
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN S853
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: C
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
16 MODULES AT 5.680 kW DC
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
GARAGE: LEFT GARAGE: LEFT
GARAGE: RIGHT GARAGE: RIGHT
SCALE: 1/16" = 1'-0"
05/26/2022
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 2 .0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
*INVERTER AND DISCONNECTING
MEANS TO BE INSTALLED IN GARAGE.
FOR MODEL HOME(S) WITH SALES
OFFICE, INVERTER AND
DISCONNECTING MEANS TO BE
INSTALLED OUTSIDE WITHIN SIGHT OF
MSP.
05/26/2022
STRUCTURAL
ENGINEERING LETTER
STRUCTURAL CALCULATIONS
MOUNT DETAILS
PV SR 2 .0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
1 SNAPNRACK ULTRA RAIL STANDOFF BASE
NOT TO SCALE 2 SNAPNRACK GROUND LUG R PRC
NOT TO SCALE
4 SNAPNRACK CONDUIT MOUNT DETAIL
NOT TO SCALE
SHEATHING, TYP.
SNAPNRACK STANDOFF
BASE STD 4-HOLE, TYP SUB-FLASHING CONE, TYP
FLASHING
CONE, TYP
TILE, TYP
CONDUIT SUPPORT
CONDUIT
TILE HOOK
TILE, TYP
SHEATHING, TYP
NOTE: TILE HOOK TO BE PLACED AT
THE HIGH POINT OF S & W TILES
SEAL PENETRATION AND BASE
WITH CHEMLINK DURALINK 35
05.17.2021
FRAMING, TYP.
2-1/2"(2) 5/16" SS LAG
SCREW, TYP.
3 SNAPNRACK MOUNT SPACING TYP.
NOT TO SCALE
CANTILEVER
L/3 OR
LESS
LANDSCAPE:
MAX 48"
SPACING (L)
PORTRAIT:
MAX 48"
SPACING (L)
MODULE, TYP.
FRAMING, TYP.
CANTILEVER
L/3 OR
LESS
MID CLAMP, TYP.MAX 10" - 16"
CANTILEVER,
TYP *
MAX
10"-16"
CANTILEVER,
TYP
*
MAX
10"
CANTILEVER,
TYP
*
MAX
10"
CANTILEVER,
TYP *
UR-60 RAIL, TYP.
ENDCLAMP, TYP.
*DEFER TO MODULE MANUFACTURER LIMITATIONS WHERE
THEIR MAXIMUM VERTICAL CANTILEVER IS SMALLER
ULTRA FOOT,
TYP.
SIDE VIEW
BONDING CHANNEL NUT
CONDUCTOR CONNECTS TO
ANOTHER GROUND LUG ON
BOTTOM RAIL OF ABOVE ROW
OF MODULES
GROUND LUG R PRC
SS SPLIT LOCK WASHER
GROUND CONDUCTOR
UR-60 RAIL
FRONT VIEW
UR-60 RAIL
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
05/26/2022
PV CS 2 .0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
CUTSHEETS
MICROINVERTER
COMBINER PANEL
MODULE
AC DISCONNECT
CUTSHEETS CONT.
RACKING
PV CS 2 .1
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-973756
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S853
DATE: 11/5/2021
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
05/26/2022