Piazza Serena TR 30092 BCPR2022-0005 (Plan 1 - S852) Solar Plans - Revision 2RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN S852
PV COVER
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
750184
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S852
DATE: 6/5/2023
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
GOVERNING CODES:
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
1. 2019 CA BUILDING CODE
2. 2019 CA ENERGY CODE
3. 2019 CA ELECTRICAL CODE
4. 2019 CA FIRE CODE
5. 2019 CA GREEN CODE
6. 2019 CA MECHANICAL CODE
7. 2019 CA PLUMBING CODE
8. 2019 CA RESIDENTIAL CODE
9. ANY OTHER LOCAL AMENDMENTS
GENERAL NOTES:
1. ELECTRICAL
1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR
SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF
THE ROOF SURFACE.
1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE.
1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN
COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE.
1.4. SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS.
2. STRUCTURAL
2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY
SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE
STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD.
2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2"
PENETRATION INTO ROOF FRAMING.
2.3. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM.
2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.
2.5. GROUND SNOW LOAD = 0 psf
2.6. WIND SPEED = 97 mph
2.7. EXPOSURE CATEGORY = C
SCOPE OF WORK
3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH BELLA AT PIAZZA
SERENA
3.1. PLAN: S852
3.2. ELEVATIONS: A, B, C
4. BUILDING INFORMATION:
4.1. BUILDING OCCUPANCY GROUP: R3/U
4.2. CONSTRUCTION TYPE: VB
5. PV
5.1. INVERTER: ENPHASE ENERGY IQ7PLUS-72-2-US
5.2. BELLA AT PIAZZA SERENA TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE:
5.2.1. JA SOLAR JAM54S31-395/MR
5.3. BELLA AT PIAZZA SERENA TO UTILIZE THE FOLLOWING SYSTEM SIZES:
5.3.1. 15 MODULES 5.925kW DC / 4.350kW AC
5.4. ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV
EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT.
M
AC
P
ROOF ACCESS POINTS
JA SOLAR JAM54S31-395/MR MODULES. ENPHASE ENERGY IQ7PLUS-72-2-US
MICROINVERTERS, MOUNTED ON THE BACK OF EACH MODULE
C
SYMBOLS AND ABBREVIATIONS:
MAIN SERVICE PANEL AND POINT OF INTERCONNECTION
PV SYSTEM AC DISCONNECT
PV SYSTEM COMBINER PANEL
UTILITY PRODUCTION METER
SHEET INDEX:
PV COVER COVER SHEET
PV RL 1.0 PV LAYOUTS
PV RL 1.1 PV LAYOUTS CONT.
PV EE 1.0 ELECTRICAL
PV SR 1.0 STRUCTURAL
PV CS 1.0 CUTSHEETS
M CAC
M
C AC
M CAC
M CAC
M
C AC
M
CAC
M
C AC
M
C AC
M
CAC
M
C AC
PV RL 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
750184
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S852
DATE: 6/5/2023
LAYOUT 1 LAYOUT 2 LAYOUT 3
LAYOUT 5 LAYOUT 6 LAYOUT 7
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
PV ROOF LAYOUTS
PLAN S852
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: A
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
ELEVATION: B
SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0"
OPTION(S): NONE
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
ELEVATION: A
OPTION(S): NONE
GARAGE: LEFT GARAGE: LEFT
GARAGE: LEFT GARAGE: LEFT
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
ELEVATION: B
OPTION(S): NONE
GARAGE: RIGHTGARAGE: RIGHTGARAGE: RIGHT
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC 15 MODULES AT 5.925 kW DC
M
CAC
M
C AC
M
C AC
M
CAC
MCAC
M
CAC
PV RL 1.1
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
750184
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S852
DATE: 6/5/2023
LAYOUT 1 LAYOUT 2 LAYOUT 3
LAYOUT 4 LAYOUT 5 LAYOUT 6
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
PV ROOF LAYOUTS
PLAN S852
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: C
GARAGE: LEFT
SCALE: 1/16" = 1'-0"
GARAGE: RIGHT
SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
ELEVATION: C
OPTION(S): NONE
GARAGE: LEFT
GARAGE: RIGHT
GARAGE: LEFT
GARAGE: RIGHT
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
15 MODULES AT 5.925 kW DC
Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)
TAG CONDUCTOR NEUTRAL GROUND CONDUIT
1 (2) 12 AWG PV WIRE NONE (1) 6 AWG BARE COPPER NONE
2 (2) 10 AWG NM NONE (1) 10 AWG NM 3/4" NM-B
3 (2) 10 AWG NM (1) 10 AWG NM (1) 8 AWG NM 3/4" NM-B
Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)
TAG CONDUCTOR NEUTRAL GROUND CONDUIT
1 (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER NONE
2 (2) 10 AWG THHN-THWN-2 NONE (1) 10 AWG THHN/THWN-2 3/4" EMT OR EQUIVALENT
3 (2) 10 AWG THHN-THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 3/4" EMT OR EQUIVALENT
OR
*DEPENDING ON INVENTORY AT TIME OF INSTALL*
Square D DU221RB,240V/30A, Unfused,NEMA3R
3
Visible/Lockable 'Knife'AC Disconnect
N
L1
L2
G
25A
Existing 240V/200A
MIN. Service Panel,
Single Phase, with 200A
Main Disconnect
M
G
N
200A
FACILITY GROUND
3
Point of Interconnection, Load Side
705.12(B)(2)(1)(b)
L1 L2 N
Builder to Ensure
SPD Compliance
(230.67)
PV Circuit 2:7 JA SOLARJAM54S31-395/MR
PV Modules /Parallel
1 2 7
NEMA 3R Junction Box
1
SI
D
E
O
F
H
O
U
S
E
IN
A
T
T
I
C
2 2
G
Combiner Panel Enphase IQ Combiner X-IQ-
AM1-240-3 64A/240V Continuous, protectionmax 80A breaker on solar output; with 10 KAIC
circuit breakers
N
15A
20A
M*
Microinverter: EnphaseIQ7PLUS-72-2-US
(Mounted to the back of each module)
PV Circuit 1:8 JA SOLARJAM54S31-395/MR
PV Modules /Parallel
1 2 8
1
2 2
20A
3
ON ROOF
Photovoltaic System
DC System Size (Watts)5925
AC System Size (Watts)4350
Total Module Count 15
Installed within 3 ft of Rapid Shutdown Switch, Reflective, and shall be
placed on the Exterior & next to Main Disconnect per 690.56(C)(3)All AC Disconnecting Means - AC Disconnect(s),
Combiner Panels, and Load Centers per 690.54
PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting
Means with min. 3/8" black capitalized text on yellow background & 3/16"
black capitalized text on white background per 690.56(C)(1)(a)
Plaque / Directory at Service Equipment Location and Power Production System Disconnecting
Means per 690.56(B) & 705.10 All Disconnecting Means - AC & DC
Disconnect(s), Load Centers, and Combiner
Panels per 690.13(B) & 690.15(D)
Power Source Output Connection, Adjacent
to Back-fed Breaker per 705.12(B)(2)(3)(b)
Dual Power Sources in Main Service Panel
and Sub Panel(s) per 705.12(B)(3)
REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8" WHITE TEXT ON RED BACKGROUND UNLESS
CAUTION: MULTIPLE SOURCES OF POWER
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECT LOCATED AS SHOWN
AT:
Meter and Main Service
AC Disconnect
DC Disconnect
WARNING
WARNING
WARNING
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN ARRAY
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT PROTECTION DEVICE
DUAL POWER SOURCE
SOURCES: UTILITY GRID AND PV SOLAR
ELECTRIC SYSTEM
MAXIMUM AC OPERATING CURRENT: 1 8 A
NOMINAL AC OPERATING CURRENT: 240V
PHOTOVOLTAIC AC DISCONNECT 1
2
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
PHOTOVOLTAIC AC DISCONNECT3
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN 4
MAXIMUM AC OUTPUT CURRENT: *** A
NOMINAL AC OPERATING VOLTAGE: *** V
SITE PLACARD SHOWING ADDITIONAL POWER SOURCE
AND DISCONNECT LOCATIONS. PLACARD SHALL BE
MOUNTED ON EXTERIOR OF ELECTRICAL PANEL
5
6
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVERCURRENT PROTECTION DEVICE
8
7 DUAL POWER SOURCE
SOURCES: UTILITY GRID
AND PV SOLAR ELECTRIC SYSTEM
MAIN BREAKER DE-RATED
DUE TO SOLAR CIRCUITS
***AMPS MAX ALLOWED
DO NOT UPGRADE
WARNING WARNING
ROOFTOP ARRAY
WITH MICROINVERTERS
2
4
1
3 5 3 5
M
ROOFTOP
JUNCTION BOX
COMBINER PANEL
(WHEN USED)
VISIBLE/LOCKABLE A/C
DISCONNECT (WHERE
REQUIRED)
VIVINT SOLAR METER
(WHERE REQUIRED)
VISIBLE/LOCKABLE A/C
DISCONNECT
TYPICAL SOLAR GENERATION INSTALLATION
(NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION)
SUB PANEL
(WHEN REQUIRED)
MAIN SERVICE
DISCONNECT PANEL
*** - value calculated for each
account, for specific value see the
previous warning label page
NS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL
3 5
3
7
5 INSIDE
PANEL
6 6 5
M
7
8
3
IF APPLICABLE
H
O
U
S
E E
X
T
E
R
I
O
R
R
O
O
F
T
O
P
&
A
T
T
IC (IF
A
P
P
LIC
A
B
L
E
)
PV Module Rating @ STC
Module Make/Model JA Solar JAM54S31-395/MR
Max. Power Point Current (Imp)12.81 Amps
Max. Power-Point Voltage (Vmp)30.84 Volts
Open-Circuit Voltage (Voc)36.98 Volts
Short-Circuit Current (Isc)13.70 Amps
Max. Series Fuse (OCPD)25 Amps
Nom. Max Power at STC (Pmax)395 Watts
Max. System Voltage 1500 DC(IEC)
Voc Temperature Coefficient -0.275 %/C
Microinverter Specs
Inverter Make/Model Enphase IQ7PLUS-72-2-US
Max. DC Volt Rating 60 Volts
Max. Power at 40 C 290 Watts
Nominal AC Voltage 240 Volts
Max. AC Current 1.21 Amps
Max. OCPD Rating 20 Amps
Max. Panels/Circuit 13
Short Circuit Current 15 Amps
Voltage and OCPD Calculations (690.7, 690.9)Other Notes
Power Source(s) Output Calc: 705.12(B)(2)(3)(b)
ASHRAE 2017 - La Quinta
Highest Monthly 2% D.B. Design Temp.: 38 °C
Lowest Min. Mean Extreme D.B.: -1 °C
Inverter Output Circuit(s): Modules per Circuit × Listed Output Current × 1.25 [art. 690.9(B)]
Circuit #1 = 8 modules × 1 A × 1.21 × 1.25 = 12 <= 20 A (OCPD)
System output current w/ continuous duty = 23 A <= 25 A (System OCPD)
Circuit #2 = 7 modules × 1 A × 1.21 × 1.25 = 12 <= 20 A (OCPD)
PV Source Max Circuit Voltage: Module Voc × (1-(T × Voc Coeff)) [art. 690.7(A)]
Conductor Calculations
Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature
calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)
PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty
uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments
without the continuous duty uprating per 690.8(B), whichever results with a larger wire size.
Non-PV Circuit conductors use the ampacity in the 75°C column or the 90°C column with the
relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) &
310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to,
the continuous duty uprated current.
More information about conductor calculations can be provided upon request.
Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current
(Tag 1 Under Array):
Inverter Output: 12 AWG N(M) rated 20 A, 20 A >= 20 A
(Tag 2 Attic):
Inverter Output: 10 AWG (NM) rated 30 A, 30 A >= 20 A
(Tag 3 Exterior):
Inverter Output: 10 AWG (NM) rated 30 A, 30 A >= 25 A
(Tag 1 Under Array):
Inverter Output: 10 AWG (THWN-2) rated 30 A, 20 A >= 20 A
(Tag 2 Attic):
Inverter Output: 10 AWG (THWN-2) rated 30 A, 20 A >= 20 A
(Tag 3 Exterior):
Inverter Output: 10 AWG (THWN-2) rated 30 A, 30 A >= 25 A
OR
*Depending on inventory at time of install*
Main Bus Rating: 200 Amps
Main Service Breaker Rating: 200 Amps
PV Uprated Output Current: 25 Amps
200A + 25A <= 200 x 1.2; 225 <= 240A, OK
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
750184
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S852
DATE: 6/5/2023
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
*INVERTER AND DISCONNECTING
MEANS TO BE INSTALLED IN GARAGE.
FOR MODEL HOME(S) WITH SALES
OFFICE, INVERTER AND
DISCONNECTING MEANS TO BE
INSTALLED OUTSIDE WITHIN SIGHT OF
MSP.
MODULES:
JA SOLAR JAM54S31-395/MR
MODULE DIMENSIONS:
67.8" x 44.65" x 1.18"
MODULE CLAMPS:
PORTRAIT: 9.84" - 17.72"
LANDSCAPE: 0" - 9.84"
LAG SCREWS:
5/16" x 4 1/2": 2 1/2"
EMBEDMENT
MAX DISTRIBUTED LOAD:
3 PSF
SNOW LOAD:
0 PSF
WIND SPEED:
97 MPH 3-SEC GUST.
STRUCTURAL NOTES:
INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY
DISCREPANCIES BEFORE PROCEEDING.
PENETRATION SPACING:
STAGGERED/FULLY STAGGERED MAY BE REQUIRED
IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT
VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY
REGION ONLY AS FOLLOWS:
ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS T0 BE REDUCED BY 50%.
ALLOWABLE OVERHANG INDICATED ON PLANS THE BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING
INDICATED ON PLANS.
WHERE MOUNTS ARE TO BE ANCHORED TO FLAT RAFTERS, MOUNTS SHALL BE INSTALLED WITH ONE OF THE
FOLLOWING OPTIONS.
OPTION 1: INSTALL ATTACHMENTS ON EVERY FLAT RAFTER UNDER ARRAY WITH REDUCED EMBEDMENT
ON FLAT 2x4 MEMBERS. USE 5/16" x 3.5" FULLY-THREADED LAG SCREWS WITH 1.5" EMBEDMENT.
OPTION 2: BLOCKING MUST BE INSTALLED TO PROCEED WITH ATTACHMENT SPACINGS AS NOTED ON
PLANSET.
WHERE MOUNTS ARE TO BE ANCHORED DIRECTLY TO HORIZANTAL TRUSSES. BLOCKING MUST BE INSTALLED
TO PROCEED WITH ATTACHMENT SPACINGS AS NOTED ON PLANSET.
GENERAL NOTES:
*THIS INFORMATION PRESENTED ON THIS PAGE IS MEANT TO ILLUSTRATE GENERAL SUNRUN MATERIALS AND
INSTALLATION PRACTICES.
*THE INFORMATION HERE IS SUBJECT TO CHANGE UNIQUE PLANS WILL BE CREATED FOR EACH BUILDING PRIOR TO
CONSTRUCTIONS FOR REVIEW.
DESIGN CRITERIA
STRUCTURAL DETAILS
ROOF INFORMATION ATTACHMENT INFORMATION
TYPE HEIGHT
ROOF PITCHES
(X:12)DETAIL MAX PORTRAIT
(OC SPACING)
MAX PORTRAIT
(OVERHANG)
MAX LANDSCAPE
(OC SPACING)
MAX LANDSCAPE
(OVERHANG)CONFIGURATION
CONCRETE TILE 1-Story 4 ULTRA RAIL, OMNIBASE, SEE DETAIL
SNR-DC-01249, UR-40 RAIL 48" L/3 48" L/3 STAGGERED
PORTRAIT:MAX 48"SPACING (L)MAX 10" - 16"CANTILEVER,TYP *
MODULE, TYP.
FRAMING, TYP.
UR-40 RAIL, TYP.
CANTILEVERL/3 OR LESS
MAX 10" - 16"CANTILEVER,TYP *
LANDSCAPE:MAX 48"SPACING (L)
*DEFER TO MODULE MANUFACTURER
LIMITATIONS WHERE THEIR MAXIMUM
VERTICAL CANTILEVER IS SMALLER.
TYPICAL MOUNT SPACING LAYOUT
NOT TO SCALE1
STRUCTURAL
STRUCTURAL DETAILS TABLE
RACKING
MOUNT DETAILS
PV SR 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
750184
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S852
DATE: 6/5/2023
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
PV CS 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
750184
HOME DEVELOPER:
RICHMOND AMERICAN HOMES
391 NORTH MAIN STREET, SUITE 205
CORONA, CA 92880
BELLA AT PIAZZA SERENA
LA QUINTA, CA
PLAN: S852
DATE: 6/5/2023
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
CUTSHEETS
MICROINVERTER
COMBINER PANEL
MODULE
AC DISCONNECT