Loading...
Andalusia TR 31681 BCPR2023-0007PLAN SNAPSHOT REPORT BCPR2023-0007 FOR CITY OF LA QUINTA Building Construction Plan Review 05/09/2023App Date:Plan No.:Plan Type:BCPR2023-0007 City of La QuintaBuilding Construction Plan Review 12/31/2025Exp Date:District:Work Class: 0.00Approved NOT COMPLETEDCompleted:Square Feet:Status: Description: Valuation: ANDALUSIA PLANS 301, 302, 303 CODE UPDATE 2022 ANDALUSIA / TRACT CONSTRUCTION PLANS 300 SERIES (SFDx3). [VB/RES-3/CLASS A-FR/13D] 2022 CALIFORNIA BUILDING CODES. PLAN 301: 3,333 S.F. PLAN 302: 3.694 S.F. PLAN 303: 4.038 S.F. REVISION 1 - PLANS 301, 302, AND 303 ENERGY REPORT UPDATED TO REFLECT AN INCREASED SOLAR PV SYSTEM SIZE, DECREASED ESS SIZE, AND ALTERNATE SYSTEM ORIENTATION. 2022 CALIFORNIA BUILDING CODES. $0.00 Assigned To:Approval Expire Date:NOT AVAILABLE Parcel:Main764620041 Address:Andalusia - Plan 301, 302 & 303 Main Zone: Applicant Nolan Sparks 81570 Carboneras La Quinta, CA 92253 Contractor Nolan Sparks 81570 Carboneras La Quinta, CA 92253 Plan Custom Fields Tract / Subdivision Name ANDALUSIA Tract Number 31681 Number of Plan Types SFDX3 Code Edition 2022 Is this a revision?No General Plan ROW City Limits Within La Quinta City Limits Acreage 3.83 Subdivision Name TR 31681-2 Lot Number S Legal Description Lot S MB 397/34 TR 31681-2 Centerlines 92340, 96269, 96418, 96268, 92339, 96877, 96417, 96267, 92341, 96879, 96416, 96878, 113092, 96415, 96866, 96126, 96125, 96124 Lot Size 22528.3 Attachment File Name Added On Added By Attachment Group Notes BCPR2023-0007 - 2ND REVIEW - COMPLETE CORRECTION LIST.pdf 09/29/2023 15:37 Clayton, Duane Available Online 2ND REVIEW CORRECTION LIST BCPR2023-0007 COA 10.2.23.pdf 10/02/2023 9:47 Cox, Chris Available Online Fire Conditions of Approval Construction Plan Set-2023-09-19-F1_v1.pdf 10/02/2023 10:01 Mendez, Deisy Available Online Construction Plan Set Construction Plan Set-2023-09-19-I1_v1.pdf 10/02/2023 10:01 Mendez, Deisy Available Online Construction Plan Set Construction Plan Set-2023-09-19-L1_v1.pdf 10/02/2023 10:01 Mendez, Deisy Available Online Construction Plan Set BCPR2023-0007 - APPROVED TRUSS PACKAGE (PLANS 301 302 303) S.pdf 10/20/2023 8:41 Clayton, Duane Internal Only APPROVED TRUSS PACKAGE PLANS 301-302-303 BCPR2023-0007 - APPROVED ENERGY REPORT (PLAN 301) S.pdf 10/20/2023 9:00 Clayton, Duane Internal Only APPROVED ENERGY REPORT PLAN 301 BCPR2023-0007 - APPROVED ENERGY REPORT (PLAN 302) S.pdf 10/20/2023 9:00 Clayton, Duane Available Online APPROVED ENERGY REPORT PLAN 302 BCPR2023-0007 - APPROVED ENERGY REPORT (PLAN 303) S.pdf 10/20/2023 9:00 Clayton, Duane Available Online APPROVED ENERGY REPORT PLAN 303 Page 1 of 378-495 Calle TampicoApril 25, 2025 PLAN SNAPSHOT REPORT (BCPR2023-0007) BCPR2023-0007 - APPROVED STRUCTURAL CALCULATIONS (PLAN 301) S.pdf 10/20/2023 9:43 Clayton, Duane Internal Only APPROVED STRUCTURAL CALCS 301 BCPR2023-0007 - APPROVED STRUCTURAL CALCULATIONS (PLAN 302) S.pdf 10/20/2023 9:43 Clayton, Duane Available Online APPROVED STRUCTURAL CALCS 302 BCPR2023-0007 - APPROVED STRUCTURAL CALCULATIONS (PLAN 303) S.pdf 10/20/2023 9:43 Clayton, Duane Available Online APPROVED STRUCTURAL CALCS 303 BCPR2023-0007 - APPROVED PLAN SET 302 S.pdf 10/20/2023 11:10 Clayton, Duane Available Online APPROVED PLAN SET 302 BCPR2023-0007 - APPROVED PLAN SET 303 S.pdf 10/20/2023 11:10 Clayton, Duane Available Online APPROVED PLAN SET 303 PLAN 302 TAKEOFF SHEET.pdf 03/20/2024 12:02 Clayton, Duane Internal Only PLAN 302 TAKE OFFS PLAN 303 TAKEOFF SHEET.pdf 03/20/2024 12:08 Clayton, Duane Internal Only PLAN 3 TAKE OFFS PLAN 301 TAKEOFF SHEET.pdf 03/20/2024 12:37 Clayton, Duane Internal Only PLAN 301 TAKE OFFS APPROVED ENERGY REPORT (PLAN 301) S.pdf 03/20/2024 14:35 Clayton, Duane Available Online APPROVED ENERGY APPROVED STRUCTURAL CALCULATIONS (PLAN 301) S.pdf 03/20/2024 14:35 Clayton, Duane Available Online APPROVED STRUCTURAL CALCULATIONS APPROVED TRUSS PACKAGE (PLANS 301 302 303) S.pdf 03/20/2024 14:35 Clayton, Duane Available Online APPROVED TRUSSES BCPR2023-0007 - APPROVED PLAN SET 301 S.pdf 07/25/2024 14:34 Clayton, Duane Internal Only APPROVED PLAN 301 REV 1 - ENERGY REPORT PLAN 301 (APPROVED)_v1.pdf 09/11/2024 8:16 Molina, Elizabeth Available Online Energy Documents REV 1 - ENERGY REPORT PLAN 302 (APPROVED)_v1.pdf 09/11/2024 8:16 Molina, Elizabeth Available Online Energy Documents REV 1 - ENERGY REPORT PLAN 303 (APPROVED)_v1.pdf 09/11/2024 8:16 Molina, Elizabeth Available Online Energy Documents Invoice No.Amount PaidFeeFee Amount INV-00009126 $22.50 Credit Card Convenience Fee $22.50 $175.00 Hourly Charge - City Building Staff $175.00 $250.00 Hourly Charge - Interwest Plan Check Engineer 2023 $250.00 $175.00 Hourly Charge - City Building Staff $175.00 $125.00 Hourly Charge - Interwest Structural Plan Review $125.00 $175.00 Hourly Charge - City Building Staff $175.00 $922.50 $922.50 Total for Invoice INV-00009126 Grand Total for Plan $922.50 $922.50 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Major Review v.1 05/09/2023 05/31/2023 07/19/2023 Yes Yes Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Major Review v.2 08/14/2023 08/28/2023 10/02/2023 Yes Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building Building Clayton, Duane Revisions Required 09/19/2023 08/28/2023 09/20/2023 Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Fire Department - Building Cases Office of the Fire Marshal Cox, Chris Ready for Approval 09/19/2023 08/28/2023 10/02/2023 Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Complete Outside Agency Clayton, Duane Revisions Required 09/19/2023 08/28/2023 09/20/2023 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedBuilding Major Review v.3 10/13/2023 10/20/2023 07/29/2024 No Yes Page 2 of 378-495 Calle TampicoApril 25, 2025 PLAN SNAPSHOT REPORT (BCPR2023-0007) Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building Building Clayton, Duane Approved 10/13/2023 10/20/2023 10/31/2023 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedBuilding Revision Review v.1 07/29/2024 08/05/2024 09/11/2024 No Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1WK)Building Clayton, Duane Approved 07/29/2024 08/05/2024 09/11/2024 Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 07/29/2024 8:39 Building Major Review v.1 Receive Submittal 09/19/2023 0:00 09/19/2023 9:29 Building Major Review v.2 Receive Submittal 09/19/2023 0:00 10/02/2023 10:01 Building Major Review v.3 Receive Submittal 10/13/2023 0:00 07/29/2024 8:39 Revisions v.1 09/11/2024 8:16 Building Revision Review v.1 Receive Submittal 07/29/2024 0:00 09/11/2024 8:16 Linked Records v.1 Linked Permits v.1 Create Sub Permit Page 3 of 378-495 Calle TampicoApril 25, 2025 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org October 2, 2023 ATTN: National Mortgage & Land Company Re: Residential Fire Access & Water / ESS Plan Review – ANDALUSIA PLANS 301, 302 and 303 CODE UPDATE 2022) BCPR2023-0007 The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their background shall be displayed on the structure and viewable from the roadway or posted at the driveway entrance and maintained visible. 2) Vehicle Gates/barricades restricting fire access to the structure are required/recommended to be provided with KNOX emergency access. (CFC 503.6) 3) Public/Private fire hydrants located in front of the property shall be provided with a minimum 3-feet radius around the hydrant of clearance of any obstructions, including vegetation. 4) Dwelling Units shall maintain a minimum 3-feet clear width Egress Court from emergency escape windows and doors of sleeping rooms and shall deposit to the front of the property or public way. These courts shall be traversable pathways, free of obstructions and landscaping intrusions. (Ref. CBC 1028.4 / CRC R311.1) 5) Energy Storage Systems shall comply with CFC 1206.11. a. Fire Detection - Areas shall be protected by smoke alarms. A listed heat detector shall be installed in locations within dwelling units and attached garages where smoke alarms cannot be installed based on their listing. b. Protection from Impact – ESS installed in a location subject to vehicle damage shall be protected by approved barriers. c. Operating Temperatures – ESS system manuals shall be consulted. Compliance with the maximum operating ambient temperatures shall be complied with. Provision of HVAC climate control may be necessary. 6) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed Contractor (C-16) shall submit plans and details for review and approval prior to system installation and Rough Inspections. The Fire Department approved plans and conditions letter must be at the job site. Applicant shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox – Fire Safety Supervisor DESIGN & DEVELOPMENT D EPARTMENT 78-495 C ALLE T AMPICO L A Q UINTA , C ALIFORNIA 92253 (760) 777 -7125 FAX (760) 777 -7011 Residential Plan Check Correction List Page 1 of 3 RESIDENTIAL PLAN CHECK CORRECTION LIST DATE: 9/20/2023 STATUS: SECOND REVIEW PLANS 201 & 202 PLAN CHECKED BY: DUANE CLAYTON TELEPHONE NUMBER: 760-777-7084 ADDRESS: 81570 CARBONERAS DESCRIPTION: NEW SFD APPLICANT: NAT’L MORTGAGE & LAND PLAN CHECK #: BCPR2023-0007 This submittal has been checked for compliance with the 2022 California Residential, Green Building and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for correction: 1 – 2ND SUBMITTAL PLAN SET THIS CORRECTION LIST DO NOT accept any resubmittal unless ALL of the following items are included: 1 – REVISED PLAN THIS CORRECTION LIST W/RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, “Sheet A-3,” or, “Handrails shall be per CBC Section 1003,” are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, “Added note 16 on sheet A-3” are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red-marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer’s name and telephone number and shall be wet-signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with yo ur resubmittal. Residential Plan Check Correction List Page 2 of 3 SECTION A - GENERAL 1) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 65% of the construction materials from landfill for the project. Contact the District Environmental Coordinator directly at (760) 674-1026 for free assistance with the preparation of this plan. SECTION B – PRECISE / SITE PLAN / ZONING 1) No comments remain. SECTION C - ARCHITECTURAL 1) No comments remain. SECTION D - MECHANICAL 1) No comments remain. SECTION E – ELECTRICAL 1) No comments remain. SECTION F - PLUMBING 1) No comments. SECTION G – ENERGY EFFICIENCY 1) PC-1: Provide complete energy calculations showing compliance with the 2022 California Energy Code for this project. Due to lack of information in this submittal, a comprehensive review will be performed at the next submittal. PC-2: Comment continues. Energy documents have been incorporated into the plan set, thank you. The azimuth orientation of the proposed pv array is called out at 180 degrees (South). I encourage the use of the California Flexible Installation (CFI) range, which is 150-270 degrees. This is typically the go-to option for tract construction where it is not possible to achieve one orientation of installation for all homes. 2) PC-1: Energy storage systems (ESS) ready. All single-family residences that include one or two dwelling units shall meet the following. All electrical components shall be installed in accordance with the Californ ia Electrical Code: 1. At least one of the following shall be provided: A. ESS ready interconnection equipment with a minimum backed -up capacity of 60 amps and a minimum of four ESS-supplied branch circuits, or B. A dedicated raceway from the main service to a panelboard (subpanel) that supplies the branch circuits in Section 150.0(s)(2). All branch circuits are permitted to be supplied by the main service panel prior to the installation of an ESS. The trade size of the raceway shall be not less than 1 inch. The panelboard that supplies the branch circuits (subpanel) must be labeled “Subpanel shall include all backed-up load circuits.” 2. A minimum of four branch circuits shall be identified and have their source of supply collocated at a single panelboard suitable to be supplied by the ESS. At least one circuit shall supply the refrigerator, one lighting circuit shall be located near the primary egress and at least one circuit shall supply a sleeping room receptacle outlet. 3. The main panelboard shall have a minimum busbar rating of 225 amps. 4. Sufficient space shall be reserved to allow future installation of a system isolation equipment/transfer switch within 3 feet of the main panelboard. Raceways shall be installed between the panelboard and the system isolation equipment/transfer switch location to allow the connection of backup power source. PC-2: Comment partially addressed. Note on plans verified, thank you. Please indicate on the single line diagram a backup capacity of 60 amps minimum for the solar panel, and indicate the four required back up circuits and the panel they are to be located in. Refer to code reference above. For reference, 400 amp split main services that have both Residential Plan Check Correction List Page 3 of 3 main overcurrent devices in the same compartment are no longer permitted in the electrical code (230.71(B)). The single line only shows one throw for the panel, but I believe the services used in the past, on that tract, have been the split main type. Clarify which type of main service is being used. Please reach out with any questions regarding this new requirement. SECTION H - CALGREEN 1) No comments. SECTION I - STRUCTURAL 1) PC-1: S1. Drawing SN1: B. Please provide a code update letter from the soils engineer. C. Please provide soils engineer stamp/signature on foundation plans and details or an updated review letter from soils engineer. D. Please coordinate sheets with originally approved set of drawings. Simpson SSW detail sheets are missing. PC-2: Comment partially addressed. Item D remains from previous review. SECTION J – SOIL / FOUNDATION 1) See comment above. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. END CORRECTION LIST As further information is provided and reviewed, additional corr ections may be required. 1500 S. Haven Ave | Suite 220 Ontario, CA 91761 909.295-3142 August 24, 2023 CITY OF LA QUINTA - SECOND REVIEW Permit No: BCPR2023-0007 Interwest No.: LAQ23-0041 Non-Structural: 0.5-hours Structural: 0.5-hours City of La Quinta Building Department 78-495 Calle Tampico La Quinta, CA 92253 Plan Review: ACC 301, 302, 303 2022 Code Updates Address: 81570 Carboneras Interwest Consulting Group has completed a second code compliance review of the following documents on behalf of the City of La Quinta: 1. Drawings: Electronic copies of following: a. CS through D-6 dated 8/14/2023 by PEKAREK. b. SN1 through SD3 dated 7/19/2023 by Gouvis. c. E-1.0 through T24.1 dated 8/8/2023 by GLS. 2. Structural Calculations: Electronic copies dated 5/8/2023 by Gouvis. 3. Energy Compliance Documentation: Electronic copies dated 8/8/2023 by GLS. 4. Geotechnical Investigation: Not provided. The applicable provisions of the 2022 California Building Standards Code were used as the basis of this review. Plan review comments follow on the attached list. Please submit an itemized response letter and complete and revised documents with directly to city of La Quinta Building and Safety Department. Sincerely, INTERWEST CONSULTING GROUP Martha Diaz, P.E. Plans Examiner mdiaz@interwestgrp.com 909.719.0249 ACC Plans (301, 302,and 303) Code Updates City of La Quinta - Second Review 59000 Madison St. Interwest Project No.: LAQ23-0041 8/24/23 Permit App: BCPR2023-0007 Page 2 of 4 PROJECT DATA: Occupancy Group: Area (sq. ft.): (301/302/303) R3 3,333/3,694/4,038 U 743/650/733 R3 (patios) 532/693/765 Total Area: 4,608/5,037/5,536 Building Height: Varies Building Stories: 1/1/1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: TBD Risk Category: II Site Class (seismic): D-default Seismic Design Category: D GENERAL COMMENTS: G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following comments reference the 2022 California Building Standards Code as amended by the authority having jurisdiction unless otherwise noted. G2. Please respond in writing to each plan review comment by marking this comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the following should be included with each plan review response: • Page / sheet number(s), detail / specification number(s), etc., and include all applicable code section(s). • Briefly explain in writing how the design is intended to comply with the applicable code sections. • Please provide a narrative of revisions made outside the plan review comments. Complete and clear responses will expedite the re-check of this project. G3. Please be sure to include on the re-submittal the architect’s and /or engineer’s stamp, signature, date of signature, and registration number on all sheets of plans depicting structural designed elements and cover sheets of calculations. CBPC 5536.1 and 6735. ACC Plans (301, 302,and 303) Code Updates City of La Quinta - Second Review 59000 Madison St. Interwest Project No.: LAQ23-0041 8/24/23 Permit App: BCPR2023-0007 Page 3 of 4 PLAN REVIEW COMMENTS: The revised permit documents have been reviewed. The following comments are numbered per the original list and require further response and/or revision. The format includes the original comment followed by a new or clarified recheck comment in bold italic typeface, prefaced by PC2. BUILDING AND LIFE SAFETY: A1. Drawing 301-3/302-3/303-3: No further comments 8/24/2023 MD ENERGY COMPLIANCE: Electrical Compliance: EE1. Drawings 301-3/302-3/303-3: No further comments 8/24/2023 MD EE2. Drawings 301-6/302-6/303-6: No further comments 8/24/2023 MD Mechanical Compliance: No comments 5/30/2023 MD Envelope Compliance: No comments 5/30/2023 MD CalGREEN: No comments 5/30/2023 MD STRUCTURAL: S1. Drawing SN1: B. Please provide a code update letter from the soils engineer. PC2. Comment remains. ACC Plans (301, 302,and 303) Code Updates City of La Quinta - Second Review 59000 Madison St. Interwest Project No.: LAQ23-0041 8/24/23 Permit App: BCPR2023-0007 Page 4 of 4 C. Please provide soils engineer stamp/signature on foundation plans and details or an updated review letter from soils engineer. PC2. Comment remains. D. Please coordinate sheets with originally approved set of drawings. Simpson SSW detail sheets are missing. PC2. Comment remains. S2. Drawing S-1.2/S-2.2/S-3.2: No further comments 8/24/2023 MD Please contact the listed reviewers between 8:00 A.M. and 12:00 P.M., M-F, with any questions. [END]