The Centre TR 37359 BCPR2021-0031 (Product 2) Master Solar Plans
ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL JAKE FUSON 9/27/2021 9/27/2021 NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS VIA EMAIL. 2ND PC SUBMITTAL RECEIVED JAKE FUSON 10/11/2021 10/11/2021 EMAIL JAKE FUSON 10/25/2021 10/25/2021 NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND FEES ARE READY FOR PAYMENT. CONDITIONS Description: CENTRE AT LA QUINTA - PRODUCT 2 / MASTER SOLAR PLANS Status: APPROVED Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB)Status Date: Subtype: SOLAR Applied: 9/16/2021 Address: 47260 ADAMS ST Approved: 10/25/2021 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: JAKE FUSON Expired: Details: CENTER AT LA QUINTA - PRODUCT 2 / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 3, & 4 FOR THE 2019 CODE CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING CODES. PLAN 1, 2 & 3: 4.9kW SOLAR ARRAY - (14) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [280SF] PLAN 4: 5.25kW SOLAR ARRAY - (15) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [300SF] Printed: Wednesday, December 20, 2023 11:55:33 AM 1 of 4 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0031 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Schellin Gerome 25323 Alessandro Blvd Moreno valley CA 92553 (951)275-4629 Schellin.Gerome@Sunp owercorp.com ARCHITECT Schellin Gerome (951)275-4629 CONTRACTOR SUNPOWER CORPORATION SYSTEMS 1414 HARBOUR WAY SOUTH #1901 RICHMOND CA 94804 (951)275-4629 Schellin.Gerome@Sunp owercorp.com OWNER Shopoff Realty Investments 2 PARK PLAZA STE 200 IRVINE CA 92614 (951)275-4629 Schellin.Gerome@sunp owercorp.com PRIMARY CONTACT Schellin Gerome 25323 Alessandro blvd #1034 Moreno valley CA 92553 (951)275-4629 Schellin.Gerome@sunp owercorp.com INSPECTIONS INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 3 $483.00 $483.00 10/26/21 WEB9711 430201461 22 CREDIT 890895 ECON Total Paid for BUILDING STAFF - PER HOUR: $483.00 $483.00 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 10/1/21 MR968 AUTHORIZE .NET PAYMENT CREDIT SHELLIN GEROME AHI Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/1/21 MR968 AUTHORIZE .NET PAYMENT CREDIT SHELLIN GEROME AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$509.00 $509.00 Printed: Wednesday, December 20, 2023 11:55:33 AM 2 of 4 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0031 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/16/2021 Etrakit Contractor 1ST MASTER PLAN SUBMITAL PV The Centre II_C002322 - MPermit.pdf 1 DOC 10/11/2021 Etrakit Contractor 2ND SUBMITTAL MASTER PLAN PV The Centre II_C002322 - MPermit(1)_Revised.pdf 1 DOC 10/11/2021 Etrakit Contractor 2ND SUBMITTAL RESPONSE LETTER The Centre II_C002322 - MPermit_Response Letter.pdf 1 BOND INFORMATION REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG (1WK)JAKE FUSON 9/16/2021 9/23/2021 9/27/2021 REVISIONS REQUIRED • REVISE THE SIGNAGE PLACARD SHEET (PVE-2) TO INCLUDE A PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. THE MARKING SHALL COMPLY WITH 110.21(B). • THE VICINITY MAP MUST BE REDUCED IN SIZE TO ACCURATELY IDENTIFY THE SITE 1ST PERMIT TECHNICIAN (1DAY) PERMIT TECH BUCKET 9/16/2021 9/17/2021 9/16/2021 COMPLETE 1ST PLANNING (1WK) CARLOS FLORES 9/16/2021 9/23/2021 9/23/2021 READY FOR APPROVAL 2ND BLDG (1WK)JAKE FUSON 10/11/2021 10/18/2021 10/25/2021 APPROVED Printed: Wednesday, December 20, 2023 11:55:33 AM 3 of 4 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0031 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/25/2021 JAKE FUSON TAKEOFF SHEETS - PLANS 1-4 BCPR2020-0031 - TAKEOFF SHEETS - PLANS 1-4.pdf 0 DOC 10/25/2021 JAKE FUSON PLAN SET (APPROVED)BCPR2021-0031 - PLAN SET (APPROVED).pdf 1 Printed: Wednesday, December 20, 2023 11:55:33 AM 4 of 4 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0031 BCPR2020-0031 – THE CENTER AT LA QUINTA – PRODUCT 2 MASTER SOLAR PLAN TAKE-OFFS PLAN 1 Permit Notes: PLAN 1 – 4.9kW SOLAR ARRAY - (14) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [280SF] 2019 CALIFORNIA BUILDING CODES. Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW o Miscellaneous Electrical Equipment - Permit issuance - Records Management Fee - Technology Enhancement Fee PLAN 2 Permit Notes: PLAN 2 - 4.9kW SOLAR ARRAY - (14) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [280SF] 2019 CALIFORNIA BUILDING CODES. Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW o Miscellaneous Electrical Equipment - Permit issuance - Records Management Fee - Technology Enhancement Fee PLAN 3 Permit Notes: PLAN 3 - 4.9kW SOLAR ARRAY - (14) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [280SF] 2019 CALIFORNIA BUILDING CODES. Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW o Miscellaneous Electrical Equipment - Permit issuance - Records Management Fee - Technology Enhancement Fee PLAN 4 Permit Notes: PLAN 4 – 5.25kW SOLAR ARRAY - (15) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [300SF] 2019 CALIFORNIA BUILDING CODES. Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW o Miscellaneous Electrical Equipment - Permit issuance - Records Management Fee - Technology Enhancement Fee SOLAR MASTER PLAN PERMIT PACKAGE SHOPOFF REALTY INVESTMENTS 2 PARK PLAZA STE 700 IRVINE, CA 92614 LA QUINTA, CALIFORNIA 92253 THE CENTRE II AT LA QUINTA PLAN 1 (1520), 2 (1777), 3 (1897), 4 (2066) CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA FIRE CODE (CFC) 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) NOT TO SCALE SHEET GENERAL NOTES: SHEET INDEX VICINITY MAP SO L A R M A S T E R P L A N P E R M I T P A C K A G E PROJECT LOCATION RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S PVA-0 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNG L E UN G 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 C002322 D-0116303 10--2021 FDEGUIA 10--2021 EOR IR V I N E , C A 9 2 6 1 4 10--2021 ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. FI L E : D - 0 1 1 5 7 9 7 - M P P P - 0 9 0 9 2 0 2 1 - S O L A R - P V A - 0 . d w g , U S E R : d d e g u i a , D A T E / T I M E : O c t 0 1 , 2 0 2 1 - 2 : 4 4 p m SOLAR ARCHITECTURAL DRAWINGS SOLAR STRUCTURAL DRAWINGS PL A N 1 ( 1 5 2 0 ) , 2 ( 1 7 7 7 ) , 3 ( 1 8 9 7 ) , 4 ( 2 0 6 6 ) MOUNTING DETAILS, STRUCTURAL INFORMATION & SPECIFICATIONS PVS-1 PVS-2 STRUCTURAL CALCULATIONS PVS-3 TYPICAL ROOF INSET DETAILS SOLAR ELECTRICAL DRAWINGS PVE-1.1 ELECTRICAL SINGLE LINE DIAGRAM PVE-2 ELECTRICAL DETAILS PVE-3 ELECTRICAL DATA & SPECIFICATIONS PVE-1.2 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.3 ELECTRICAL SINGLE LINE DIAGRAM PVA-0 PVA-1 COVER SHEET PVA-2 PVA-3 PVA-4 PLAN 1 (1520) ELAVATION A, B, C PLAN 2 (1777) ELAVATION A, B, C PLAN 3 (1897) ELAVATION A, B, C PLAN 4 (2066) ELAVATION A, B, C BCPR2021-0031 CENTER AT LA QUINTA - PRODUCT 2 / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 3, & 4 FOR THE 2019 CODE CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING CODES. PLAN 1, 2 & 3: 4.9kW SOLAR ARRAY - (14) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [280SF] PLAN 4: 5.25kW SOLAR ARRAY - (15) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [300SF] 10/25/2021 LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION 03 LAYOUT 1 LAYOUT 2 FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 1 (1520) - ELEVATION A - FLAT TILE PLAN 1 (1520) - ELEVATION B - S-TILE PLAN 1 (1520) - ELEVATION C - S-TILE NOTE : ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY. BASE SQUARE FOOTAGE: 1520 SQ. FT. SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 14 4.90 kW DESCRIPTION (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) 01 02 ----------------------------------- ----------------------------------- ----------------------------------- FRONT OF HOUSE : 240° - 360°FRONT OF HOUSE : 150° - 270° TO ELECTRIC UTILITY GRID TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S PVA-1 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G FI L E : D - 0 1 1 5 7 9 7 - M P P P - 0 9 0 9 2 0 2 1 - S O L A R - P V A - 1 . d w g , U S E R : d d e g u i a , D A T E / T I M E : S e p 0 9 , 2 0 2 1 - 1 1 : 0 8 a m PL A N 1 ( 1 5 2 0 ) E L E V A T I O N A , B , C 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 SCALE 3/32" - 1'-0" & ' )'(*8,$ (25 10/25/2021 LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- FRONT OF HOUSE : 60° - 180° & 240° - 360°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 60° - 90°LAYOUT 3 FRONT OF HOUSE : 330° - 0°LAYOUT 4 04 05 ----------------------------------- ----------------------------------- LAYOUT 1 FRONT OF HOUSE : 330° - 90°FRONT OF HOUSE : 330° - 0°LAYOUT 3 LAYOUT 4 PLAN 2 (1777) - ELEVATION B - S-TILE PLAN 2 (1777) - ELEVATION C - S-TILE NOTE : ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY. BASE SQUARE FOOTAGE: 1777 SQ. FT. SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 14 4.90 kW LAYOUT 2 FRONT OF HOUSE : 60° - 90° PLAN 2 (1777) - ELEVATION A - FLAT TILE ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINT TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH) ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID FRONT OF HOUSE (FOH) ROOF ACCESS POINT FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE : 150° - 270° & 330° - 90° FRONT OF HOUSE : 150° - 270° & 330° - 90° SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S PVA-2 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G FI L E : D - 0 1 1 5 7 9 7 - M P P P - 0 9 0 9 2 0 2 1 - S O L A R - P V A - 2 . d w g , U S E R : d d e g u i a , D A T E / T I M E : S e p 0 9 , 2 0 2 1 - 1 1 : 0 9 a m PL A N 2 ( 1 7 7 7 ) E L E V A T I O N A , B , C 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 SCALE 3/32" - 1'-0" & ' )'(*8,$ (25 10/25/2021 LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 3 (1897) - ELEVATION A - FLAT TILE PLAN 3 (1897) - ELEVATION B - S-TILE PLAN 3 (1897) - ELEVATION C - S-TILE NOTE : ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY. BASE SQUARE FOOTAGE: 1897 SQ. FT. SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 14 4.90 kW (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TRANSITION BOX (TYP.)ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S PVA-3 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G FI L E : D - 0 1 1 5 7 9 7 - M P P P - 0 9 0 9 2 0 2 1 - S O L A R - P V A - 3 . d w g , U S E R : d d e g u i a , D A T E / T I M E : S e p 0 9 , 2 0 2 1 - 1 1 : 1 0 a m PL A N 3 ( 1 8 9 7 ) E L E V A T I O N A , B , C 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 SCALE 3/32" - 1'-0" & ' )'(*8,$ (25 10/25/2021 DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- LEGEND: ARE 3' WIDE FIRE ACCESS PATH LAYOUT 2 PLAN TYPE OPTION LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 LAYOUT 1 FRONT OF HOUSE : 330° - 90° PLAN 4 (2066) - ELEVATION A - FLAT TILE PLAN 4 (2066) - ELEVATION C - S-TILE 04 05 ----------------------------------- ----------------------------------- LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 4 (2066) - ELEVATION B - S-TILE NOTE : ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY. BASE SQUARE FOOTAGE: 2066 SQ. FT. SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 15 5.25 kW (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX (TYP.) ROOF ACCESS POINTFRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINTFRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID TRANSITION BOX (TYP.) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM FRONT OF HOUSE : 150° - 270° & 330° - 90° (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID ROOF ACCESS POINTFRONT OF HOUSE (FOH) ROOF ACCESS POINT FRONT OF HOUSE : 150° - 270° & 330° - 90° (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TO ELECTRIC UTILITY GRID FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) FRONT OF HOUSE : 150° - 270° & 330° - 90° SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S PVA-4 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G FI L E : D - 0 1 1 5 7 9 7 - M P P P - 0 9 0 9 2 0 2 1 - S O L A R - P V A - 4 . d w g , U S E R : d d e g u i a , D A T E / T I M E : S e p 0 9 , 2 0 2 1 - 1 1 : 0 4 a m PL A N 4 ( 2 0 6 6 ) E L E V A T I O N A , B , C 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 SCALE 1/16" - 1'-0" & ' )'(*8,$ (25 10/25/2021 6+((7 5( 9 ' ( 6 & 5 , 3 7 , 2 1 ' $ 7 ( ' % & % 5 ( 9 , 6 , 2 1 6 127726&$/( + $ 5 % 2 8 5 : $ < 6 2 8 7 + 5 , & + 0 2 1 ' & $ 7+ , 6 ' 2 & 8 0 ( 1 7 & 2 1 7 $ , 1 6 3 5 2 3 5 , ( 7 $ 5 < , 1 ) 2 5 0 $ 7 , 2 1 5 ( 3 5 2 ' 8 & 7 , 2 1 ', 6 & / 2 6 8 5 ( 2 5 8 6 ( : , 7 + 2 8 7 6 3 ( & , ) , & : 5 , 7 7 ( 1 $ 8 7 + 2 5 , = $ 7 , 2 1 2 ) 7 + ( 68 1 3 2 : ( 5 & 2 5 3 2 5 $ 7 , 2 1 , 6 6 7 5 , & 7 / < ) 2 5 % , ' ' ( 1 & 2 5 3 2 5 $ 7 , 2 1 6 < 6 7 ( 0 6 & $ / , & ( 1 6 ( '5$:1%< 352-(&7 '$7('5$:1 23325781,7< &+(&.('%< '$7(&+(&.(' PVS- ),*85(,19,6,028176,'(9,(:'(7$,/6 ),*85(,19,6,02817522)$77$&+0(17'(7$,/6 ),*85(02817,1*&/$03326,7,21,1*'(7$,/6),*85(3(1(75$7,21*8,'()25,167$// x x ),*85(7<3,&$/$55$<,1)250$7,21 02 8 1 7 , 1 * ' ( 7 $ , / 6 6 7 5 8 & 7 8 5 $ / , 1 ) 2 5 0 $ 7 , 2 1 6 3 ( & , ) , & $ 7 , 2 1 6 3(*$686&20363(&,),&$7,216+((73* 3(*$686&20363(&,),&$7,216+((73*,19,6,02817'$7$6+((7 &(57,),&$7(2)&203/,$1&(&/$66$),5(5$7,1*8//,67,1*3* &/$66$),5(5$7,1*8//,67,1*3* &/$66$),5(5$7,1*8//,67,1*3* COMP MOUNTS Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804venue, R : 510.210.3797 www.pegasussolar.com WATERTIGHT FOR LIFE Pegasus Solar's Comp Mounts are a cost effective, high-quality option for rail installations on composition shingle roofs. Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail. A BETTER DAY ON THE JOB Simple 3-piece design for rapid installation Encapsulating design raises the water seal 0.9" above roof deck One-piece flashing with elevated cone – No press-fits or deck-level EPDM washers to fail 25-year Warranty Manufactured with advanced materials and coatings to outlast the roof itself Superior Waterproong Tested to AC286 without sealant 0.9" elevated water seal Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-16 Standards All-In-One Kit Packaging Flashings, L-Feet and SS lags with bonded EPDM washers are included in each 24-pack COMP MOUNTS Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804venue, R : 510.210.3797 www.pegasussolar.com 1.Drill pilot hole in center of rafter. 3.Place L-Foot over cone and install lag with washer through L-Foot. 2.Optional: Apply a "U-shape" of sealant to underside of flashing and postition under 2nd shingle course, cone over pilot hole. 4.Drive lag to required depth. Attach rail per rail manufacturer's instructions. Comp Mount Install Kits Boxes per Pallettents Pending. All rPa ights reserved.eserved. 2019 Pegasus S PSCR-CBB0 Closed Slot L-Foot, Flashing, 5/16"x 4-1/2" SS Lag with metalized EPDM washer PSCR-UBB0 Open Slot L-Foot, Flashing, 5/16"x 4-1/2" SS Lag with metalized EPDM washer SPCR-CBBH Closed Slot L-Foot, Flashing, 5/16"x 4-1/2" SS Lag with metalized EPDM washer and M10 Hex Bolt Black L-Foot and Black Flashing Most Composition Shingle IBC, ASCE/SEI 7-16, AC286 Railed Systems Galvalume Plus Aluminum 24 72 L-Foot Type Kit Contents SKU Kit Quantity L-Foot Material Flashing Material Compatible Rail Install Application Certifications Roof Type Finish Closed Slot PSCR-CMM0 L-Foot, Flashing, 5/16"x 4-1/2" SS Lag with metalized EPDM washer Mill L-Foot and Mill Flashing Painted Galvalume Plus PSCR-UMM0 Open Slot L-Foot, Flashing, 5/16"x 4-1/2" SS Lag with metalized EPDM washer SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Mid clamp Black oxide stainless steel 300 series 63 g (2.2 oz) End clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Rail bolt M10-1.5 × 25 mm; custom T-head SS304 18 g (0.63 oz) Rail nut M10-1.5; DIN 6923 SS304 nominal Ground lug assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g (3.75 oz) Row-to-row grounding clip SS 301 with SS 304 M6 bolts 75 g (2.6 oz) Row-to-row spacer Black POM-grade plastic 5 g (0.18 oz) Roof Attachment Hardware Supported by Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal interface for other roof attachments InvisiMount Operating Conditions Temperature ȫr&WRr&ȫr)WRr) Max. Load (LRFD)• 3000 Pa uplift • 6000 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation. ΖQYLVL0RXQW:DUUDQWLHV$QG&HUWLȴFDWLRQV Warranties • 25-year product warranty • \HDUȴQLVKZDUUDQW\ &HUWLȴFDWLRQV • UL 2703 Listed • Class A Fire Rated Professional Engineer (PE) must then stamp all calculations. If you have any questions please contact SunPower Technical Support at 1-855-977-7867. © 2018 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. $OORWKHUWUDGHPDUNVDUHWKHSURSHUW\RIWKHLUUHVSHFWLYHRZQHUV6SHFLȴFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH InvisiMount Components Module¹ / Mid Clamp and Rail Mid Clamp End Clamp Rail and Rail Splice Ground Lug Assembly Module¹ / End Clamp and Rail sunpower.com 509506 RevF ¹ Module frame that is compatible with the InvisiMount system required for hardware interoperability.² SunPower recommends that all Equinox™, InvisiMount™, and AC module systems always be designed using the InvisiMount Span Tables #524734. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed InvisiMount Component LRFD Capacities² Mid clamp Uplift 664 lbf Shear 540 lbf End clamp Uplift 899 lbf Shear 220 lbf Rail Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft Rail splice Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft L-foot Uplift 1000 lbf Shear 390 lbf Datasheet Row-to-Row Spacer Row-to-Row Grounding Clip CERTIFICATE OF COMPLIANCE Certificate Number 20161025-E466981 Report Reference E466981-20140903 Issue Date 2016-OCTOBER-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 1 Issued to: SUNPOWER CORP This is to certify that representative samples of 77 RIO ROBLES SAN JOSE CA 95134-1859 MOUNTING SYSTEMS, MOUNTING DEVICES, CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS InvisiMount Mounting and Bonding Systems for use with Photovoltaic Modules, consisting of the following components: L-Foot, Rail, Rail Splice, Mid Clamp, Ground Lug Assembly, End Clamp, SolarEdge P400 Microinverter Backplate, Row Clip Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 2703, the Standard for Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for use with Flat-Plate Photovoltaic Modules and Panels Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 10/3/2018 QIMS.E466981 - Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Pan… https://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QIMS.E466981&ccnshorttitle=Mounting+Systems,+Mounting+…1/3 QIMS.E466981 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels 3DJH%RWWRP Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels 6HH*HQHUDO,QIRUPDWLRQIRU0RXQWLQJ6\VWHPV0RXQWLQJ'HYLFHV&ODPSLQJ'HYLFHVDQG*URXQG/XJVIRU8VHZLWK3KRWRYROWDLF0RGXOHVDQG 3DQHOV (SUNPOWER CORP 5,252%/(6 6$1-26(&$86$ Cat. No. Investigated for Bonding Investigated for Mechanical Loading System Fire Classification (A, B or C) Tested in Combination With Photovoltaic mounting system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ounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Pan… https://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QIMS.E466981&ccnshorttitle=Mounting+Systems,+Mounting+…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ounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Pan… https://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QIMS.E466981&ccnshorttitle=Mounting+Systems,+Mounting+…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onnection Calculator Design Method /RDG 5HVLVWDQFH)DFWRU'HVLJQ/5)' Connection Type /DWHUDOORDGLQJ Fastener Type /DJ6FUHZ Loading Scenario 6LQJOH6KHDU Main Member Type 'RXJODV)LU/DUFK Main Member Thickness LQ Main Member: Angle of Load to Grain Side Member Type 3O\ZRRG6WUXFWXUDOJUDGH Side Member Thickness LQ Side Member: Angle of Load to Grain Washer Thickness LQ Nominal Diameter LQ Length LQ Time Effect Factor Wet Service Factor &B0 End Grain Factor &BHJ Temperature Factor &BW Connection Yield Modes Im 1797 lbs. Is 309 lbs. II 592 lbs. IIIm 627 lbs. IIIs 287 lbs. IV 405 lbs. Adjusted LRFD Capacity 287 lbs. Lag Screw bending yield strength of 60000 psi is assumed. The Adjusted LRFD Capacity is only applicable for lag screws with adequate end distance, edge distance and spacing per NDS chapter 11. While every effort has been made to insure the accuracy of the information presented, and special effort has been made to assure that the information reflects the state-of-the-art, neither the American Wood Council nor its members assume any responsibility for any particular design prepared from this on-line Connection Calculator. Those using this on-line Connection Calculator assume all liability from its use. The Connection Calculator was designed and created by Cameron Knudson, Michael Dodson and David Pollock at Washington State University. Support for development of the Connection Calculator was provided by American Wood Council. Connection Calculator Design Method /RDG 5HVLVWDQFH)DFWRU'HVLJQ/5)' Connection Type :LWKGUDZDOORDGLQJ Fastener Type /DJ6FUHZ Loading Scenario 1$ Main Member Type 'RXJODV)LU/DUFK Main Member Thickness LQ Side Member Type 3O\ZRRG6WUXFWXUDOJUDGH Side Member Thickness LQ Washer Thickness LQ Nominal Diameter LQ Length LQ Time Effect Factor Wet Service Factor &B0 End Grain Factor &BHJ Temperature Factor &BW Adjusted LRFD Capacity 898 lbs. The Adjusted LRFD Capacity only applies to withdrawal of the fastener from the main member. It does not address head pull-through capacity of the fastener in the side member. While every effort has been made to insure the accuracy of the information presented, and special effort has been made to assure that the information reflects the state-of-the-art, neither the American Wood Council nor its members assume any responsibility for any particular design prepared from this on-line Connection Calculator. Those using this on-line Connection Calculator assume all liability from its use. The Connection Calculator was designed and created by Cameron Knudson, Michael Dodson and David Pollock at Washington State University. Support for development of the Connection Calculator was provided by American Wood Council. $6&(522)=21(6 LFootCompRoof 20 ft 19 deg 0.332 5.12 ft 3.43 ft 2.56 ft 40 ft 60 ft PropertiesandDimensions: RoofHeight RoofSlope PVModuleLongDimension PVModuleShortDimension RailTributaryWidth GableEndWidth,W RidgeLength,L DeadLoads: 0.22 psf 0.563 plf 2.835 psf 46 lbf 7.258 plf 6.862 plf 2.363 plf 10 psf 1.2 0.9 1 0.927 7.56 psf 7.01 psf 16.97 plf 5.843 plf Rail Module LoadNormaltoPVSurface: LoadParalleltoPVSurface: SnowLoads: GroundSnowLoad,pg Ct Ce Is Cs FlatRoofSnowLoad,pf SlopedRoofSnowLoad,ps LoadNormaltoPVSurface LoadParalleltoPVSurfae ComponentsandCladdingExternalPressureCoefficients V110mph Kz 0.9 …uniformweight …distributedweight …uniformweight …totalweight ..alongrail …alongrail …alongrail …unheatedandopentoair …exposureC,fullyexposed …RiskCategoryII …alongrail …alongrail …meanroofheight=20 ft Kzt 1 Kd 0.85 Ke 1 qh 23.7 psf 1of7 ComponentsandCladdingExternalPressueCoefficients(GableRoofͲRoof) Zone 2n 2e 2n 2r 3 3e 3r 0to7 Ͳ3.2 11'2 Ͳ1.7 Ͳ0.9 Ͳ2.3 0.3 0.3 0.3 0.3 7to20 Ͳ2 Ͳ3 Ͳ3 Ͳ3 Ͳ3.6 0.7 0.7 0.7 0.7 0.7 20to27 Ͳ1.7 Ͳ2.5 Ͳ2.5 Ͳ2.5 Ͳ3.6 0.7 0.7 0.7 0.7 0.7 27to45 Ͳ1.8 Ͳ2 Ͳ1.8 Ͳ3.2 Ͳ2 Ͳ2 0.7 Ͳ1.7 0.7 Ͳ1.8 0.9 0.9 0.9 0.9 0.9 0.9 gammaE1 gammaA0.8 Zone 1 1' 2 2n 2e 2n 2r 3 3e 3r 0to7 Ͳ32.23 Ͳ17.06 Ͳ43.6 0 0 0 0 5.687 5.687 5.687 0 0 0 0 Ͳ60.66 0 0 5.687 0 0 7to20 Ͳ37.91 0 0 0 Ͳ37.9146 Ͳ56.87 Ͳ56.87 0 Ͳ56.87 Ͳ68.25 13.27 0 0 0 13.2701 13.27 13.27 0 13.27 13.27 Ͳ32.23 0 0 0 Ͳ32.2274 Ͳ47.39 Ͳ47.39 0 Ͳ47.39 Ͳ68.25 13.27 0 0 0 13.2701 13.27 13.27 0 13.27 13.27 Ͳ34.12 0 0 0 Ͳ34.1232 Ͳ37.91 Ͳ34.12 0 Ͳ60.66 Ͳ37.91 17.06 0 0 0 17.0616 17.06 17.06 0 17.06 17.06 1 1' 2 2n 2e 2n 2r 3 3e 3r Ͳ37.91 0 0 0 Ͳ37.9146 Ͳ56.87 Ͳ56.87 0 Ͳ56.87 Ͳ68.25 13.27 0 0 0 13.2701 13.27 13.27 0 13.27 13.27 11'22n Ͳ111.6 Ͳ87.36 0 2e 2n 2r 3 3e 3r 0 Ͳ150.445 Ͳ145.6 Ͳ145.6 Ͳ140.7 Ͳ179.6 Ͳ174.7 33.97 0 0 0 33.9715 33.97 33.97 0 33.97 33.97 33.97 plf 12 ft ft4 20to27 27to45 Zone DesignWindPressure,Up DesignWindPressure,Dwn Zone WindLoadAlongRail,Up WindLoadAlongRail,Dwn WindLoadAlongRail,Dwn,AllZones ZoneDimensions 0.6*h a 2of7 3g D 1 3 2 1 1 1.5 1 4.536 psf 1.134 psf 11.61 plf …alongrail 2.903 plf …alongrail 6.525 plf 11.92 plf 9.607 plf 52.37 plf 50.69 plf SeismicLoads: Ss SiteClass Fa Sms Sds Ip ap Rp z/h Fp Fv HorizontalLoad,Eh VerticalLoad,Ev LoadNormaltoPVSurfae(+/Ͳ) LoadParalleltoPVSurfae(+/Ͳ) LoadCombinationsͲAlongtheRail 1.4D 1.2D+1.6S+0.5W(allzones) 1.2D+0.5S+1.0W(allzones) 1.2D+1.0E+0.2S 18.15 plf Ͳ105.4 plf Ͳ144.3 plf Ͳ173.4 plf 3.308 plf 12.18 plf 5.757 plf 15.93 plf 0.9D+1.0W(Zone1) 0.9D+1.0W(Zone2) 0.9D+1.0W(Zone3) 1.4D 1.2D+1.6S 1.2D+0.5S 1.2D+1.0E+0.2S 0.9D 2.127 plf …alongrail …alongrail …down,normaltoPVsurface …down,normaltoPVsurface …down,normaltoPVsurface …down,normaltoPVsurface …up,normaltoPVsurface …up,normaltoPVsurface …up,normaltoPVsurface …down,paralleltoPVsurface …down,paralleltoPVsurface …down,paralleltoPVsurface …down,paralleltoPVsurface …down,paralleltoPVsurface MaximumDemandsonRailandConnections Ͳ105.4 plf Ͳ144.3 plf Ͳ173.4 plf 52.37 plf WorstCaseUpliftͲZone1 WorstCaseUpliftͲZone2 WorstCaseUpliftͲZone3 WorstCaseDownward WorstCaseSeismicDemand 18.15 plf 12.18 plfWorstCaseShearforDownwardCases WorstCaseShearforSeismicCases 15.93 plf 3of7 72 in 48 in 48 in 24 in 16 in 16 in Ͳ474.5 lbfͲft Ͳ288.5 lbfͲft Ͳ346.8 lbfͲft Ͳ548 lbfͲft 0.866 OKAY 253.7 lbfͲft 104.7 lbfͲft 104.7 lbfͲft 580 lbfͲft 0.406 OKAY Ͳ632.7 lbf Ͳ577.1 lbf Ͳ693.6 lbf Ͳ1072 lbf 0.647 OKAY 314.2 lbf 209.5 lbf 209.5 lbf 999 lbf MaximumAllowableSpacings DesignedAttachmentSpacing,Zone1 DesignedAttachmentSpacing,Zone2 DesignedAttachmentSpacing,Zone3 MaxAllowableCantilever,Zone1 MaxAllowableCantilever,Zone2 MaxAllowableCantilever,Zone3 CheckStrenghtofRail Zone1Mmax,up=1/8*w*L2 Zone2Mmax,up=1/8*w*L2 Zone3Mmax,up=1/8*w*L2 Mallow,up AllZonesDCR Zone1Mmax,down=1/8*w*L2 Zone2Mmax,down=1/8*w*L2 Zone3Mmax,down=1/8*w*L2 Mallow,dwn AllZonesDCR AttachmentAllowableLoads Zone1,Tup=w*L Zone2,Tup=w*L Zone3,Tup=w*L Tattach,up AllZonesDCR Zone1Pdown=w*L Zone2Pdown=w*L Zone3Pdown=w*L Pattach,down AllZonesDCR 0.315 OKAY 95.57 lbf 63.71 lbf 63.71 lbf 390 lbf 390 lbf 390 lbf Zone1Vattach=w*L Zone2Vattach=w*L Zone3Vattach=w*L Zone1Vattach,shear Zone2Vattach,shear Zone3Vattach,shear AllZonesDCR 0.245 OKAY 4of7 Ͳ632.7 lbf Ͳ577.1 lbf Ͳ693.6 lbf Ͳ898 lbf 0.772 OKAY 95.57 lbf 63.71 lbf 63.71 lbf 287 lbf LagBoltAllowableLoads Zone1,Tup=w*L Zone2,Tup=w*L Zone3,Tup=w*L Tlag,up AllZonesDCR Zone1Vattach=w*L Zone2Vattach=w*L Zone3Vattach=w*L Vlag,shear AllZonesDCR 0.333 OKAY 5of7 CBCB TH E C E N T R E I I A T L A Q U I N T A LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 IR V I N E , C A 9 2 6 1 4 & ' )'(*8,$ (25 10/25/2021 ),*85(&21&5(7(7,/(72&20326,7,21#7232)$55$<),*85(&20326,7,2172&21&5(7(7,/(#%277202)$55$<),*85(&20326,7,2172&21&5(7(7,/(#6,'(2)$55$< ),*85(*60723),1)/$6+,1*#6,'(2),16(7 '(7$,/6,16+((7396$5(6+2:1)25(;$03/(385326(621/<)25$7<3,&$/&20326,7,21 $63+$/76+,1*/(6,16(7,167$//$7,2121$&21&5(7(7,/(522)'(7$,/6$5(68%-(&772&+$1*( $1',6127$6&23()2562/$53+27292/7$,&,167$//$7,21,16(7,167$//$7,21$5(,167$//('%< 27+(567<3,&$//<$522)&2175$&725+,5('%<*(1(5$/&2175$&725 ),*85(,620(75,&2)723&251(52),16(7 7< 3 , & $ / 5 2 2 ) , 1 6 ( 7 ' ( 7 $ , / 6 6+((7 5( 9 ' ( 6 & 5 , 3 7 , 2 1 ' $ 7 ( ' % 5 ( 9 , 6 , 2 1 6 127726&$/( + $ 5 % 2 8 5 : $ < 6 2 8 7 + 5 , & + 0 2 1 ' & $ 7+ , 6 ' 2 & 8 0 ( 1 7 & 2 1 7 $ , 1 6 3 5 2 3 5 , ( 7 $ 5 < , 1 ) 2 5 0 $ 7 , 2 1 5 ( 3 5 2 ' 8 & 7 , 2 1 ', 6 & / 2 6 8 5 ( 2 5 8 6 ( : , 7 + 2 8 7 6 3 ( & , ) , & : 5 , 7 7 ( 1 $ 8 7 + 2 5 , = $ 7 , 2 1 2 ) 7 + ( 68 1 3 2 : ( 5 & 2 5 3 2 5 $ 7 , 2 1 , 6 6 7 5 , & 7 / < ) 2 5 % , ' ' ( 1 & 2 5 3 2 5 $ 7 , 2 1 6 < 6 7 ( 0 6 & $ / , & ( 1 6 ( FI L E : D r a w i n g 4 . d w g , U S E R : m e b i t e , D A T E / T I M E : S e p 1 3 , 2 0 1 8 - 1 1 : 2 7 a m '5$:1%< 352-(&712 '$7('5$:1 &20081,7<,' &+(&.('%< '$7(&+(&.(' PVS- CBCB TH E C E N T R E I I A T L A Q U I N T A LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 IR V I N E , C A 9 2 6 1 4 & ' )'(*8,$ (25 10/25/2021 FIGURE A: SINGLE LINE DIAGRAM - 4.90 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 25A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 7 AC MODULESBRANCH CIRCUIT #2 7 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) ATTIC ROOFTOP AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 7 VOLTAGE 240 V BRANCH CURRENT: IOUT = 9.17 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 11.46 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 15.81 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 #10 0.59% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 11.46 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 7 VOLTAGE 240 V BRANCH CURRENT: IOUT = 9.17 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 11.46 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 15.81 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 #10 0.59% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 11.46 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #10 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 18.34 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 22.93 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 22.37 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.19% OVERCURRENT PROTECTION 25A, 2P MINIMUM OCPD = IOUT x 1.25 22.93 A OCPD SIZE 25 A CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP VOLTAGE DROP AT 62 FT DISTANCE CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP VOLTAGE DROP AT 62 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.1 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 & ' )'(*8,$ (25 10/25/2021 FIGURE A: SINGLE LINE DIAGRAM - 5.25 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 25A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 7 AC MODULESBRANCH CIRCUIT #2 8 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) ATTIC ROOFTOP AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 8 VOLTAGE 240 V BRANCH CURRENT: IOUT = 10.48 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.36% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 13.10 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 7 VOLTAGE 240 V BRANCH CURRENT: IOUT = 9.17 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 11.46 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 15.81 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.46% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 11.46 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #10 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 19.65 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 24.56 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 23.96 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.20% OVERCURRENT PROTECTION 25A, 2P MINIMUM OCPD = IOUT x 1.25 24.56 A OCPD SIZE 25 A VOLTAGE DROP AT 33 FT DISTANCE VOLTAGE DROP AT 49 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.2 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 & ' )'(*8,$ (25 10/25/2021 FIGURE A: SINGLE LINE DIAGRAM - 5.25 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 25A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 4 AC MODULESBRANCH CIRCUIT #2 11 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) ATTIC ROOFTOP AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 11 VOLTAGE 240 V BRANCH CURRENT: IOUT = 14.41 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 18.01 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 24.84 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.74% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 18.01 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 4 VOLTAGE 240 V BRANCH CURRENT: IOUT = 5.24 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 6.55 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 9.03 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.14% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 6.55 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #10 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 19.65 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 24.56 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 23.96 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.20% OVERCURRENT PROTECTION 25A, 2P MINIMUM OCPD = IOUT x 1.25 24.56 A OCPD SIZE 25 A VOLTAGE DROP AT 50 FT DISTANCE VOLTAGE DROP AT 26 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.3 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 & ' )'(*8,$ (25 10/25/2021 ),*85(:,5,1*522)3(1(75$7,21&52666(&7,21 ),*85((/(&75,&$/6,*1$*(667,&.(56 6,*1$*(127(6 WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE x x x TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM x x x PHOTOVOLTAIC SYSTEM COMBINER PANEL: DO NOT ADD LOADS x x x x x x x PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: N:'& N:'& N:'& N:'& AC SOLAR DISCONNECT x (/ ( & 7 5 , & $ / ' ( 7 $ , / 6 6+((7 5( 9 ' ( 6 & 5 , 3 7 , 2 1 ' $ 7 ( ' % & % 5 ( 9 , 6 , 2 1 6 127726&$/( SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNG L E UN G + $ 5 % 2 8 5 : $ < 6 2 8 7 + 5 , & + 0 2 1 ' & $ 7+ , 6 ' 2 & 8 0 ( 1 7 & 2 1 7 $ , 1 6 3 5 2 3 5 , ( 7 $ 5 < , 1 ) 2 5 0 $ 7 , 2 1 5 ( 3 5 2 ' 8 & 7 , 2 1 ', 6 & / 2 6 8 5 ( 2 5 8 6 ( : , 7 + 2 8 7 6 3 ( & , ) , & : 5 , 7 7 ( 1 $ 8 7 + 2 5 , = $ 7 , 2 1 2 ) 7 + ( 68 1 3 2 : ( 5 & 2 5 3 2 5 $ 7 , 2 1 , 6 6 7 5 , & 7 / < ) 2 5 % , ' ' ( 1 & 2 5 3 2 5 $ 7 , 2 1 6 < 6 7 ( 0 6 & $ / , & ( 1 6 ( '5$:1%< 352-(&712 '$7('5$:1 &20081,7<,' &+(&.('%< '$7(&+(&.(' 7+ ( & ( 1 7 5 ( , , $ 7 / $ 4 8 , 1 7 $ 6+ 2 3 2 ) ) 5 ( $ / 7 < , 1 9 ( 6 7 0 ( 1 7 6 3 $ 5 . 3 / $ = $ 6 7 ( /$ 4 8 , 1 7 $ & $ / , ) 2 5 1 , $ ,5 9 , 1 ( & $ 5 ( 9 , 6 , 2 1 6 PVE-2 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: &$87,21 $''5(66 PHOTOVOLTAICAC DISCONNECT 3+27292/7$,&$55$<21522) MAIN SERVICEPANEL SOLAR LOADCENTER '5 , 9 ( : $ < 7<3,&$/',5(&725<3/$&$5' 127( &86720,=('3/$&$5':,//%(3529,'(')25($&+/2781,7 & ' )'(*8,$ (25 10/25/2021 CURRENT TRANSFORMER SPECIFICATION SHEET AC DISCONNECT DATA SHEET PV MODULE SPECIFICATION SHEET PG PVS6 DATASHEET 1 PVS6 DATASHEET 2 PVS6 INSTALLATION INSTRUCTIONS 1 PVS6 INSTALLATION INSTRUCTIONS 2 PV MODULE COMPLIANCE LETTER CERTIFICATE OF COMPLIANCE FOR WIRING SYSTEM AND HARNESS SOLADECK DATA SHEET EL E C T R I C A L D A T A & S P E C I F I C A T I O N S SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) FI L E : D - 0 1 1 5 7 9 7 - M P P P - 0 9 0 9 2 0 2 1 - S O L A R - P V E - 4 . d w g , U S E R : d d e g u i a , D A T E / T I M E : S e p 0 9 , 2 0 2 1 - 1 1 : 3 6 a m 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E C E N T R E I I A T L A Q U I N T A SH O P O F F R E A L T Y I N V E S T M E N T S 2 P A R K P L A Z A S T E 7 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 1 4 PVE-3 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G & ' )'(*8,$ (25 10/25/2021