Loading...
Stone Creek Ranch TR 30834 BCPR2021-0033Description: STONE CREEK / MASTER SOLAR PLANS - 2019 CODE CYCLE Status: APPROVED Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB)Status Date: Subtype: SOLAR Applied: 9/17/2021 Address: 80310 AVENUE 58 Approved: City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: JAKE FUSON Expired: Details: STONE CREEK RANCH / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 3, 4, & 4X FOR THE 2019 CODE CYCLE. 2019 CALIFORNIA BUILDING CODES. ***NOTE: ALL PV SYSTEMS HAVE THE OPTION TO ADD A 13kWh SUNVAULT ENERGY STORAGE SYSTEM W/ SUNVAULT HUB+ & 100A BACKUP LOADS PANEL. PLAN 1 (DALEA): 7.0kW SOLAR ARRAY - (20) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [400SF]. PLAN 1 (DALEA) W/OPTIONAL CASITA: 7.35kW SOLAR ARRAY - (21) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [420SF]. PLAN 2 (LARREA): 6.65kW SOLAR ARRAY - (19) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [380SF]. PLAN 2 (LARREA) W/OPTIONAL MULTI-GEN SUITE: 7.0kW SOLAR ARRAY - (20) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [400SF]. PLAN 3 (JUBILEE): 7.35kW SOLAR ARRAY - (21) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [420SF]. PLAN 3 (JUBILEE) W/OPTIONAL MULTI-GEN SUITE: 7.7kW SOLAR ARRAY - (22) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [440SF]. Printed: Wednesday, December 20, 2023 11:59:09 AM 1 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL JAKE FUSON 9/28/2021 9/28/2021 NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT CORRECTION LIST VIA EMAIL. 3RD PC SUBMITTAL RECEIVED JAKE FUSON 1/5/2022 1/5/2022 EMAIL JAKE FUSON 2/3/2022 2/3/2022 NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND PLAN CHECK FEE IS READY FOR PAYMENT. EMAIL JAKE FUSON 5/19/2022 5/19/2022 NOTIFIED APPLICANT THAT REVISION 1 PLANS ARE APPROVED AND FEE IS READY FOR PAYMENT. EMAIL JAKE FUSON 10/19/2022 10/19/2022 NOTIFIED APPLICANT THAT REVISION 2 IS APPROVED AND READY FOR FEE PAYMENT. EMAIL JAKE FUSON 1/31/2023 1/31/2023 NOTIFIED APPLICANT OF REVISION 3 - 1ST REVIEW COMMENTS. PLAN 4 (TECOMA): 5.95kW SOLAR ARRAY - (17) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [340SF]. PLAN 4X (TECOMA): 8.4kW SOLAR ARRAY - (24) 350W SUNPOWER SPR-X21-350-BLK MODULES-E-AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [480SF]. REVISION 1 - REVISED AND ADDED ROOF LAYOUTS (NO CHANGE TO SYSTEM SIZE OR ATTRIBUTES). REVISION 2 - ADDED ROOF LAYOUT OPTIONS FOR PLAN TYPE 1. REVISION 3 - VARIOUS FIELD CHANGES. REVISION 4 UPDATED LAYOUTS 3 AND 4 OF ELEVATION C, FOR PLAN TYPE 4. Printed: Wednesday, December 20, 2023 11:59:09 AM 2 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT Schellin Gerome 25323 Alessandro Blvd Moreno valley CA 92553 (951)275-4629 Schellin.Gerome@Sunp owercorp.com CONTRACTOR SUNPOWER CORPORATION SYSTEMS 1414 HARBOUR WAY SOUTH #1901 RICHMOND CA 94804 (951)275-4629 Schellin.Gerome@Sunp owercorp.com OWNER TOLL BROTHERS 725 Town and Country Rd #200 ORANGE CA 92868 (951)275-4629 Schellin.Gerome@sunp owercorp.com PRIMARY CONTACT Schellin Gerome 25323 alessandro blvd moreno valley ca 92553 (951)275-4629 schellin.Gerome@sunp owercorp.com EMAIL JAKE FUSON 7/6/2023 7/6/2023 NOTIFIED APPLICANT THAT REVISION #3 IS APPROVED AND READY FOR FEE PAYMENT. CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 4 $644.00 $644.00 2/4/22 WEB10621 635202087 13 CREDIT 890895 ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 5/23/22 WEB11860 637300479 59 CREDIT 890895 ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 10/24/22 WEB13403 745134063 CREDIT 890895 ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 1.5 $241.50 $241.50 7/6/23 WEB15624 111514388 7 CREDIT 890895 ECON Total Paid for BUILDING STAFF - PER HOUR: $1,046.50 $1,046.50 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 10/1/21 MR968 AUTHORIZE .NET PAYMENT CREDIT SHELLIN GEROME AHI Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 Printed: Wednesday, December 20, 2023 11:59:09 AM 3 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 INSPECTIONS INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES REVIEWS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 10/1/21 MR968 AUTHORIZE .NET PAYMENT CREDIT SHELLIN GEROME AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$1,072.50 $1,072.50 REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG (1WK)JAKE FUSON 9/17/2021 9/24/2021 9/27/2021 REVISIONS REQUIRED 1ST BLDG (1WK)JAKE FUSON 4/8/2022 4/15/2022 5/19/2022 APPROVED REVISION 1 REVISION 1 - REVISED AND ADDED ROOF LAYOUTS. 1ST BLDG (1WK)JAKE FUSON 8/26/2022 9/2/2022 10/19/2022 APPROVED REVISION 2 REVISION 2 - ADDED ROOF LAYOUT OPTIONS FOR PLAN TYPE 1. 1ST BLDG (1WK)JAKE FUSON 10/25/2022 11/1/2022 1/31/2023 PENDING DOCUMENTS REVISION 3 REVISED LAYOUTS SUBMITTED 10/24/22 (REV. #3) ARE APPROVABLE HOWEVER DIRECTION HAS BEEN GIVEN TO THE APPLICANT TO COMBINE REVISIONS 3 & 4 SINCE THEY WERE BOTH SUBMITTED PRIOR TO THIS REVIEW BEING COMPLETED. ALSO, THE REVISION 4 NARRATIVE DOES NOT EXPLAIN THE CHANGES SO CLARIFICATION OF THE CHANGES HAS BEEN REQUESTED. 1ST BLDG (1WK)BUILDING BUCKET 7/10/2023 7/17/2023 REVISION 4 1ST PERMIT TECHNICIAN (1DAY) PERMIT TECH BUCKET 9/17/2021 9/20/2021 9/17/2021 COMPLETE Printed: Wednesday, December 20, 2023 11:59:09 AM 4 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/10/2022 AJ ORTEGA TAKEOFF SHEETS (PV SYSTEMS) BCPR2021-0033 - TAKEOFF SHEETS (PV SYSTEMS).pdf 1 DOC 8/15/2023 DUANE CLAYTON APPROVED REVISION 4 PLAN SET BCPR2021-0033 - APPROVED REVISION 4 PLAN SET CF.pdf 1 DOC 9/17/2021 Etrakit Contractor 1ST MASTER PLAN PV SUBMITTAL C002189 - Stone Creek - MPermit3509(v3).pdf 1 DOC 10/27/2021 Etrakit Contractor 2ND SUBMITTAL RESUBMIT LETTER C002189 - Stone Creek - Response Letter.pdf 1 DOC 10/27/2021 Etrakit Contractor 2ND SUBMITTAL MASTER PV PLAN C002189 - Stone Creek - MPermit 350_Reivsed.pdf 1 DOC 1/5/2022 Etrakit Contractor 3RD SUBMITTAL MASTER PV PLAN C002189 - Stone Creek - MPermit 350_1.pdf 1 DOC 1/5/2022 Etrakit Contractor 3RD SUBMITTAL RESUBMITTAL LETTER C002189 - Stone Creek - Response Letter_V3.pdf 1 BOND INFORMATION 1ST PLANNING (1WK) CARLOS FLORES 9/17/2021 9/24/2021 9/24/2021 READY FOR APPROVAL 2ND BLDG (1WK)JAKE FUSON 10/27/2021 11/3/2021 11/29/2021 REVISIONS REQUIRED -PROVIDE INSTALLATION GUIDES FOR THE HUB+, SUNVAULT ESS, MICROGRID INTERCONNECTION DEVICE AND REMOTE POWER OFF SWITCH -ALL ALUMINUM CONDUCTORS MUST BE 1/0 OR LARGER, RESIZE #2 AWG EGC CONDUCTORS 2ND BLDG NS (2WK)JAKE FUSON 3/27/2023 4/3/2023 5/11/2023 PENDING DOCUMENTS REVISION 3 SAME COMMENTS APPLY, REVISIONS 3 & 4 HAVE STILL NOT BEEN COMBINED. 3RD BLDG (1WK)JAKE FUSON 1/5/2022 1/12/2022 2/3/2022 APPROVED 3RD BLDG (1WK)JAKE FUSON 5/19/2023 5/26/2023 7/6/2023 APPROVED REVISION 3 REVISION 3 - VARIOUS FIELD CHANGES. Printed: Wednesday, December 20, 2023 11:59:09 AM 5 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/5/2022 Etrakit Contractor 3RD SUBMITTAL SUNVAULT GUIDE SunPower SunVault Installation Guide 536685 RevD September 2021.pdf 1 DOC 1/5/2022 Etrakit Contractor 3RD SUBMITTAL SUNVAULT LETTER Sunvault State Letter 03 -26- 2021_CA_Stamped_Cert .pdf 1 DOC 1/5/2022 Etrakit Contractor 3RD SUBMITTAL SUNVAULT DETAILS Sunvault_536400_B_det ails_CA_03-26- 2021_Stamped.pdf 1 DOC 4/8/2022 Etrakit Contractor REVISION 1 - 1ST SUBMITTAL PLAN C002189 - Stone Creek - MPermit 350_current.pdf 1 DOC 4/8/2022 Etrakit Contractor REVISION 1 - NARRATIVE OF CHANGES C002189 - Stone Creek - Resubmittal Letter.pdf 1 DOC 8/26/2022 Etrakit Contractor REVISION 2 - 1ST SUBMITTAL PLAN SHEETS C002189 - Stone Creek - MPermit 350_2.pdf 1 DOC 8/26/2022 Etrakit Contractor REVISION 2 - 1ST SUBMITTAL NARRATIVE OF CHANGES C002189 - Stone Creek - Resubmittal Letter_1.pdf 1 DOC 10/24/2022 Etrakit Contractor REVISION 3 - 1ST SUBMITTAL MASTER SOLAR PLANS C002189 - Stone Creek - MPermit 350_2_3.pdf 1 DOC 10/24/2022 Etrakit Contractor REVISION 3 - 1ST SUBMITTAL NARRATIVE OF CHANGES C002189 - Stone Creek - Resubmittal Letter_2.pdf 1 Printed: Wednesday, December 20, 2023 11:59:09 AM 6 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 1/23/2023 Etrakit Contractor REVISION 4 - 1ST SUBMITTAL NARRATIVE OF CHANGES Stone Creek - MPPP - D- 0124419 - Revised Solar Master Plans - Resubmittal Letter.pdf 1 DOC 1/23/2023 Etrakit Contractor REVISION 4 - 1ST SUBMITTAL MASTER SOLAR PLANS Stone Creek - MPPP - D- 0124419 - Revised Solar Master Plans_1.pdf 1 DOC 3/27/2023 Etrakit Contractor REVISION 3 - 2ND SUBMITTAL SOLAR PLAN C002189 - Stone Creek - MPermit 350(2).pdf 1 DOC 3/27/2023 Etrakit Contractor REVISION 3 - 2ND SUBMITTAL NARRATIVE C002189 - Stone Creek - Resubmittal Letter_2.pdf 1 DOC 5/19/2023 Etrakit Contractor REVISION 3 - 3RD SUBMITTAL PLANS (INCLUDES PREVIOUS REVISION 4) C002189 - Stone Creek - MPermit 350(4).pdf 1 DOC 5/19/2023 Etrakit Contractor REVISION 3 - 3RD SUBMITTAL NARRATIVE (INCLUDES PREVIOUS REVISION 4) C002189 - Stone Creek - Resubmittal Letter (1).pdf 1 DOC 7/7/2023 Etrakit Contractor REVISION 4 - 1ST SUBMITTAL NARRATIVE Stone Creek - MPPP - D- 0126237 - Revised Solar Master Plans - Resubmittal Letter - BCPR2021-0033.pdf 1 DOC 7/7/2023 Etrakit Contractor REVISION 4 - 1ST SUBMITTAL PLANS - Updated layout 3 & 4 of elevation C for Plan 4 Stone Creek - MPPP - D- 0126237 - Revised Solar Master Plans - BCPR2021-0033.pdf 1 Printed: Wednesday, December 20, 2023 11:59:09 AM 7 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/28/2021 JAKE FUSON 1ST REVIEW CORRECTION LIST BCPR2021-0033 - 1ST REVIEW CORRECTION LIST.pdf 1 DOC 2/3/2022 JAKE FUSON MASTER SOLAR PLAN (APPROVED) BCPR2021-0033 - MASTER SOLAR PLAN (APPROVED).pdf 1 DOC 5/19/2022 JAKE FUSON REVISION 1 - SOLAR MASTER PLAN SHEETS (APPROVED) BCPR2021-0033 - REVISION 1 - SOLAR MASTER PLAN SHEETS (APPROVED).pdf 1 DOC 10/19/2022 JAKE FUSON REVISION 2 - PLAN SHEETS (APPROVED) BCPR2021-0033 - REVISION 2 - PLAN SHEETS (APPROVED).pdf 1 DOC 7/6/2023 JAKE FUSON REVISION 3 - PLAN SHEETS (APPROVED) BCPR2021-0033 - REVISION 3 - PLAN SHEETS (APPROVED).pdf 1 Printed: Wednesday, December 20, 2023 11:59:09 AM 8 of 8 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0033 BCPR2021‐0033 – STONE CREEK RANCH MASTER  SOLAR PLAN TAKE‐OFFS  Note: ***NOTE: ALL PV SYSTEMS HAVE THE OPTION TO ADD A 13kWh  SUNVAULT ENERGY STORAGE SYSTEM W/ SUNVAULT HUB+ & 100A BACKUP  LOADS PANEL. IF THIS OPTION IS TAKEN:    1. Add “+ 13kWh SUNVAULT ENERGY STORAGE SYSTEM W/ SUNVAULT HUB+ &  100A BACKUP LOADS PANEL.” to permit notes.  2. Add an additional (2) Miscellaneous Electrical Equipment fees      PLAN 1 (DALEA)    Permit Notes:  7.0kW SOLAR ARRAY ‐ (20) 350W SUNPOWER SPR‐X21‐350‐BLK MODULES‐E‐AC  PANELS W/  INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [400SF] SEE MASTER PLAN  APPROVAL BCPR2021‐0033 FOR EQUIPMENT SPECIFICATION AND SIGNAGE SHEETS. 2019  CALIFORNIA BUILDING CODES.  Permit Description:  STONE CREEK / 7.0kW PV SYSTEM ‐ (20) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 7.0  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 1 (DALEA) w/OPTIONAL CASITA    Permit Notes:  PLAN 1 (DALEA) W/OPTIONAL CASITA: 7.35kW SOLAR ARRAY ‐ (21) 350W SUNPOWER SPR‐X21‐350‐ BLK  MODULES‐E‐AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER  [420SF] SEE MASTER PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT SPECIFICATION AND  SIGNAGE SHEETS. 2019 CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 7.35kW PV SYSTEM ‐ (21) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  o Electrical 2019PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 7.35  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 2 (LARREA)    Permit Notes:  PLAN 2 (LARREA): 6.65kW SOLAR ARRAY ‐ (19) 350W SUNPOWER SPR‐X21‐350‐BLK MODULES‐E‐AC  PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [380SF] SEE MASTER  PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT SPECIFICATION AND SIGNAGE SHEETS. 2019  CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 6.65kW PV SYSTEM ‐ (19) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 6.65  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 2 (LARREA) w/OPTIONAL MULTI‐GEN SUITE    Permit Notes:  PLAN 2 (LARREA) W/OPTIONAL MULTI-GEN SUITE: 7.0kW SOLAR ARRAY ‐ (20) 350W SUNPOWER  SPR‐  X21‐350‐BLK MODULES‐E‐AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV  LOAD CENTER [400SF] SEE MASTER PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT  SPECIFICATION AND SIGNAGE SHEETS. 2019 CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 7.0kW PV SYSTEM ‐ (20) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 7.0  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 3 (JUBILEE)    Permit Notes:  PLAN 3 (JUBILEE): 7.35kW SOLAR ARRAY ‐ (21) 350W SUNPOWER SPR‐X21‐350‐BLK MODULES‐E‐AC  PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [420SF] SEE MASTER  PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT SPECIFICATION AND SIGNAGE SHEETS. 2019  CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 7.35kW PV SYSTEM ‐ (21) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 7.35  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 3 (JUBILEE) w/ OPTIONAL MULTI‐GEN SUITE    Permit Notes:  PLAN 3 (JUBILEE) W/OPTIONAL MULTI-GEN SUITE: 7.7kW SOLAR ARRAY ‐ (22) 350W SUNPOWER  SPR‐  X21‐350‐BLK MODULES‐E‐AC PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV  LOAD CENTER [440SF] SEE MASTER PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT  SPECIFICATION AND SIGNAGE SHEETS. 2019 CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 7.7kW PV SYSTEM ‐ (22) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 7.7  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 4 (TECOMA)    Permit Notes:  PLAN 4 (TECOMA): 5.95kW SOLAR ARRAY ‐ (17) 350W SUNPOWER SPR‐X21‐350‐BLK MODULES‐E‐AC  PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [340SF] SEE MASTER  PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT SPECIFICATION AND SIGNAGE SHEETS. 2019  CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 5.95kW PV SYSTEM ‐ (17) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 5.95  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1      PLAN 4X (TECOMA)    Permit Notes:  PLAN 4X (TECOMA): 8.4kW SOLAR ARRAY ‐ (24) 350W SUNPOWER SPR‐X21‐350‐BLK MODULES‐E‐AC  PANELS W/ INTEGRATED IQ 7XS MICROINVERTERS + 100A PV LOAD CENTER [480SF] SEE MASTER  PLAN APPROVAL BCPR2021‐0033 FOR EQUIPMENT SPECIFICATION AND SIGNAGE SHEETS. 2019  CALIFORNIA BUILDING CODES.  Permit Description:   STONE CREEK / 8.4kW PV SYSTEM ‐ (24) 350W PANELS+MICRO  Fee Breakdown:  ‐ Building Standards Administration (BSAS)  ‐ Electrical 2019  o PV System less than 10kW  o PV System less than 10kW PC  o Misc. Electrical  o Misc. Electrical PC  ‐ Permit issuance  ‐ Records Management Fee  ‐ Technology Enhancement Fee  Custom Screens:  ‐ System size (kW): 8.4  ‐ Strings: 2  ‐ Misc. Electrical Equip: 1