Stone Creek Ranch TR 30834 BCPR2021-0017 - Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
GENERAL INFORMATION
01 Project Name Plan 1-The Dalea
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft
2)2879 19 Glazing Percentage (%)22.11%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
REVIEWED
Sep 09, 2021
INTERWEST CONSULTING GROUP
FOR
CODE COMPLIANCE
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 50.6 24.4
Proposed Designs
North Facing 45.1 19.6 5.5 4.8
East Facing 49.8 24.3 0.8 0.1
South Facing 46.1 20.6 4.5 3.8
West Facing 47.3 21.8 3.3 2.6
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 6.31 kWdc
•Proposed PV Capacity Scaling: North (6.78 kWdc) East (6.78 kWdc) South (6.78 kWdc) West (6.78 kWdc)
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.09 2.36 -0.27 -12.9
Space Cooling 95.71 79.38 16.33 17.1
IAQ Ventilation 2.4 2.4 0 0
Water Heating 7.41 6.71 0.7 9.4
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 107.61 90.85 16.76 15.6
Space Heating 2.09 2.92 -0.83 -39.7
Space Cooling 95.71 93.05 2.66 2.8
IAQ Ventilation 2.4 2.4 0 0
Water Heating 7.41 6.71 0.7 9.4
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 107.61 105.08 2.53 2.4
Space Heating 2.09 3.25 -1.16 -55.5
Space Cooling 95.71 81.41 14.3 14.9
IAQ Ventilation 2.4 2.4 0 0
Water Heating 7.41 6.71 0.7 9.4
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 107.61 93.77 13.84 12.9
Space Heating 2.09 3.05 -0.96 -45.9
Space Cooling 95.71 85.29 10.42 10.9
IAQ Ventilation 2.4 2.4 0 0
Water Heating 7.41 6.71 0.7 9.4
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 107.61 97.45 10.16 9.4
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
6.78 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1-The Dalea 2879 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 2879 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 siding Home R-21 Wall 0 Front 273.8 78.8 90
Front Wall 2X6 Home R-21 + R-4 0 Front 375.5 40 90
Left Wall 2X6 siding Home R-21 Wall 90 Left 133.2 0 90
Left Wall 2X6 Home R-21 + R-4 90 Left 605 107 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 888 394.8 90
Right Wall 2X6 siding Home R-21 Wall 270 Right 27.8 0 90
Right Wall 2X6 Home R-21 + R-4 270 Right 466.2 40 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 470.9 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 2879 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 237.8 128 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 233.1 20 90
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 451 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 siding Front 0 1 78.8 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Front Wall 2X6 Front 0 1 16 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Left Wall 2X6 Left 90 1 35 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Left Wall 2X6 Left 90 9 8 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall 2X6 Back 180 1 234.8 0.29 NFRC 0.22 NFRC Bug Screen
Window OH 2 Window Rear Wall 2X6 Back 180 20 8 1 160 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Right Wall 2X6 Right 270 1 40 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 24 0.142857
Door 2 Garage Wall 21.3 0.5
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 3 Front Wall 128 1
Door 4 Right Wall 20 1
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 12 1 2 2 0 0 0 0 0 0 0 0 0
Window OH 2 11 1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 2879 250 None 80%No
Slab 2 __Garage__451 42 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 8.5 38000 36000 16 13 Not Zonal
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 117 0.25 Default 0 n/a
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea Calculation Date/Time:2021-07-20T06:41:24-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 06:43:50
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:16:59
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:01
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115397B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
GENERAL INFORMATION
01 Project Name Plan 1-The Dalea_Opt Casita
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft
2)3199 19 Glazing Percentage (%)19.94%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 50.8 24.2
Proposed Designs
North Facing 44.5 19.6 6.3 4.6
East Facing 49 24.1 1.8 0.1
South Facing 45.6 20.7 5.2 3.5
West Facing 46.4 21.5 4.4 2.7
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 7.06 kWdc
•Proposed PV Capacity Scaling: North (7.32 kWdc) East (7.32 kWdc) South (7.32 kWdc) West (7.32 kWdc)
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.91 2.12 -0.21 -11
Space Cooling 95.16 76.84 18.32 19.3
IAQ Ventilation 2.47 2.47 0 0
Water Heating 7.35 6.64 0.71 9.7
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 106.89 88.07 18.82 17.6
Space Heating 1.91 2.61 -0.7 -36.6
Space Cooling 95.16 89.78 5.38 5.7
IAQ Ventilation 2.47 2.47 0 0
Water Heating 7.35 6.64 0.71 9.7
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 106.89 101.5 5.39 5
Space Heating 1.91 2.94 -1.03 -53.9
Space Cooling 95.16 79.26 15.9 16.7
IAQ Ventilation 2.47 2.47 0 0
Water Heating 7.35 6.64 0.71 9.7
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 106.89 91.31 15.58 14.6
Space Heating 1.91 2.74 -0.83 -43.5
Space Cooling 95.16 81.88 13.28 14
IAQ Ventilation 2.47 2.47 0 0
Water Heating 7.35 6.64 0.71 9.7
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 106.89 93.73 13.16 12.3
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
7.32 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1-The Dalea_Opt Casita 3199 1 5 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 3199 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 siding Home R-21 Wall 0 Front 273.8 78.8 90
Front Wall 2X6 Home R-21 + R-4 0 Front 375.5 40 90
Left Wall 2X6 siding Home R-21 Wall 90 Left 133.2 0 90
Left Wall 2X6 Home R-21 + R-4 90 Left 704.9 115 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 888 388 90
Right Wall 2X6 siding Home R-21 Wall 270 Right 27.8 0 90
Right Wall 2X6 Home R-21 + R-4 270 Right 577.2 64 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 470.9 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 3199 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 237.8 128 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 233.1 20 90
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 451 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 siding Front 0 1 78.8 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Front Wall 2X6 Front 0 1 16 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Left Wall 2X6 Left 90 1 43 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Left Wall 2X6 Left 90 9 8 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall 2X6 Back 180 1 228 0.29 NFRC 0.22 NFRC Bug Screen
Window OH 2 Window Rear Wall 2X6 Back 180 20 8 1 160 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Right Wall 2X6 Right 270 1 40 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 24 0.142857
Door 2 Right Wall 2X6 24 0.2
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 3 Garage Wall 21.3 0.2
Door 4 Front Wall 128 1
Door 5 Right Wall 20 1
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 12 1 2 2 0 0 0 0 0 0 0 0 0
Window OH 2 10 1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 3199 269 None 80%No
Slab 2 __Garage__451 42 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 8.5 38000 36000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 134 0.25 Default 0 n/a
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1-The Dalea_Opt Casita Calculation Date/Time:2021-07-20T07:08:35-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 1-The Dalea_Opt Casita.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:11:00
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:17:29
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:01
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115398B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
GENERAL INFORMATION
01 Project Name Plan 2 - The Larrea
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.31
18 Total Cond. Floor Area (ft
2)3156 19 Glazing Percentage (%)20.03%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 50.2 24.3
Proposed Designs
North Facing 44.5 21.7 5.7 2.6
East Facing 47.1 24.3 3.1 0
South Facing 46.2 23.5 4 0.8
West Facing 43.8 21 6.4 3.3
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 6.58 kWdc
•Proposed PV Capacity Scaling: North (6.39 kWdc) East (6.39 kWdc) South (6.39 kWdc) West (6.39 kWdc)
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.03 2.04 -0.01 -0.5
Space Cooling 93.03 77.06 15.97 17.2
IAQ Ventilation 2.33 2.33 0 0
Water Heating 6.76 6.13 0.63 9.3
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 104.15 87.56 16.59 15.9
Space Heating 2.03 2.26 -0.23 -11.3
Space Cooling 93.03 84.35 8.68 9.3
IAQ Ventilation 2.33 2.33 0 0
Water Heating 6.76 6.13 0.63 9.3
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 104.15 95.07 9.08 8.7
Space Heating 2.03 3.1 -1.07 -52.7
Space Cooling 93.03 81.02 12.01 12.9
IAQ Ventilation 2.33 2.33 0 0
Water Heating 6.76 6.13 0.63 9.3
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 104.15 92.58 11.57 11.1
Space Heating 2.03 2.72 -0.69 -34
Space Cooling 93.03 74.18 18.85 20.3
IAQ Ventilation 2.33 2.33 0 0
Water Heating 6.76 6.13 0.63 9.3
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 104.15 85.36 18.79 18
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
6.39 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2 - The Larrea 3156 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 3156 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 siding Home R-21 Wall 0 Front 83.3 28 90
Front Wall 2X6 Home R-21 + R-4 0 Front 127.7 18 90
Left Wall 2X6 Home R-21 + R-4 90 Left 995.3 202 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 666 352 90
Right Wall 2X6 Home R-21 + R-4 270 Right 733.6 60 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 715.1 42.7 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 3156 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 455.1 164 90
Left Wall __Garage__R-0 Wall 90 Left 99 0 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 359 64 90
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 651 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 Front 0 1 18 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Wall 2X6 Left 90 1 130 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Left Wall 2X6 Left 90 9 8 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2X6 Back 180 1 192 0.29 NFRC 0.22 NFRC Bug Screen
Window Oh(2)Window Rear Wall 2X6 Back 180 20 8 1 160 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Wall 2X6 Right 270 1 60 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Front Wall Front 0 1 36 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 siding 28 0.142857
Door 2 Garage Wall 42.7 0.2
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 3 Front Wall 128 1
Door 4 Right Wall 64 1
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 12 1 2 2 0 0 0 0 0 0 0 0 0
Window Oh(2)11 1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 3156 235 None 80%No
Slab 2 __Garage__651 82 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 9 45500 43000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 125 0.25 Default 0 n/a
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea Calculation Date/Time:2021-07-20T07:17:03-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:19:42
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:18:05
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:01
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115401B-000-000-0000000-0000 2021-07-21 14:16:01 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
GENERAL INFORMATION
01 Project Name Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft
2)3366 19 Glazing Percentage (%)20.56%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 49.6 24.1
Proposed Designs
North Facing 44.6 21.8 5 2.3
East Facing 46.9 24.1 2.7 0
South Facing 46.1 23.3 3.5 0.8
West Facing 44.3 21.5 5.3 2.6
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 6.77 kWdc
•Proposed PV Capacity Scaling: North (6.68 kWdc) East (6.68 kWdc) South (6.68 kWdc) West (6.68 kWdc)
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2 2.33 -0.33 -16.5
Space Cooling 90.99 77.07 13.92 15.3
IAQ Ventilation 2.28 2.28 0 0
Water Heating 6.34 5.74 0.6 9.5
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 101.61 87.42 14.19 14
Space Heating 2 2.54 -0.54 -27
Space Cooling 90.99 83.3 7.69 8.5
IAQ Ventilation 2.28 2.28 0 0
Water Heating 6.34 5.74 0.6 9.5
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 101.61 93.86 7.75 7.6
Space Heating 2 3.15 -1.15 -57.5
Space Cooling 90.99 80.34 10.65 11.7
IAQ Ventilation 2.28 2.28 0 0
Water Heating 6.34 5.74 0.6 9.5
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 101.61 91.51 10.1 9.9
Space Heating 2 2.85 -0.85 -42.5
Space Cooling 90.99 75.65 15.34 16.9
IAQ Ventilation 2.28 2.28 0 0
Water Heating 6.34 5.74 0.6 9.5
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 101.61 86.52 15.09 14.9
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
6.68 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2 - The Larrea_Opt Gen
Suite I.L.O Garage
3366 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 3366 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 siding Home R-21 Wall 0 Front 299.7 64 90
Front Wall 2X6 Home R-21 + R-4 0 Front 127.7 18 90
Left Wall 2X6 Home R-21 + R-4 90 Left 1017.5 202 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 666 352 90
Right Wall 2X6 Home R-21 + R-4 270 Right 562.4 24 90
Right Wall 2X6 siding Home R-21 Wall 270 Right 297.9 60 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 394.1 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 3366 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 238.7 128 90
Left Wall __Garage__R-0 Wall 90 Left 76.8 0 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 232.2 0 90
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 441 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 siding Front 0 1 36 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Front Wall 2X6 Front 0 1 18 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Left Wall 2X6 Left 90 1 130 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Left Wall 2X6 Left 90 9 8 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall 2X6 Back 180 1 192 0.29 NFRC 0.22 NFRC Bug Screen
Window Oh(2)Window Rear Wall 2X6 Back 180 20 8 1 160 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Right Wall 2X6 Right 270 1 24 0.29 NFRC 0.22 NFRC Bug Screen
Window 6 Window Right Wall 2X6 siding Right 270 1 60 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 siding 28 0.2
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 2 Garage Wall 21.3 0.2
Door 3 Front Wall 128 1
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 12 1 2 2 0 0 0 0 0 0 0 0 0
Window Oh(2)11 1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 3366 268 None 80%No
Slab 2 __Garage__441 49 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 8.5 38000 36000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 131 0.25 Default 0 n/a
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 - The Larrea_Opt Gen Suite I.L.O Garage Calculation Date/Time:2021-07-20T07:23:36-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 2-The Larrea_Opt Gen Suite I.L.O Garage 2.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:26:21
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:18:38
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:02
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115406B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
GENERAL INFORMATION
01 Project Name Plan 3-The Jubilee
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.32
18 Total Cond. Floor Area (ft
2)3908 19 Glazing Percentage (%)21.00%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 48.8 24
Proposed Designs
North Facing 44.9 22.8 3.9 1.2
East Facing 46.1 24 2.7 0
South Facing 45.5 23.4 3.3 0.6
West Facing 43.5 21.4 5.3 2.6
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 7.26 kWdc
•Proposed PV Capacity Scaling: North (7.11 kWdc) East (7.11 kWdc) South (7.11 kWdc) West (7.11 kWdc)
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.88 2.12 -0.24 -12.8
Space Cooling 86.79 76.43 10.36 11.9
IAQ Ventilation 2.19 2.19 0 0
Water Heating 5.46 4.95 0.51 9.3
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 96.32 85.69 10.63 11
Space Heating 1.88 2.27 -0.39 -20.7
Space Cooling 86.79 79.48 7.31 8.4
IAQ Ventilation 2.19 2.19 0 0
Water Heating 5.46 4.95 0.51 9.3
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 96.32 88.89 7.43 7.7
Space Heating 1.88 2.8 -0.92 -48.9
Space Cooling 86.79 77.28 9.51 11
IAQ Ventilation 2.19 2.19 0 0
Water Heating 5.46 4.95 0.51 9.3
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 96.32 87.22 9.1 9.4
Space Heating 1.88 2.41 -0.53 -28.2
Space Cooling 86.79 72.31 14.48 16.7
IAQ Ventilation 2.19 2.19 0 0
Water Heating 5.46 4.95 0.51 9.3
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 96.32 81.86 14.46 15
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
7.11 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3-The Jubilee 3908 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 3908 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 siding Home R-21 Wall 0 Front 321.9 99 90
Left Wall 2X4 Home R-13 Wall + R-4 90 Left 133.2 72 90
Left Wall 2X6 Home R-21 + R-4 90 Left 801.1 124 90
Rear Wall 2X4 Home R-13 Wall + R-4 180 Back 327.5 192 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 449.6 200 90
Right Wall 2X6 Home R-21 + R-4 270 Right 940.7 157.5 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 455.1 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 3908 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 455.1 90 90
Left Wall __Garage__R-0 Wall 90 Left 362.6 148 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 362.6 84 90
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 664 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 siding Front 0 1 75 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Wall 2X4 Left 90 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Left Wall 2X6 Left 90 1 124 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Rear Wall 2X4 Back 180 20 8 1 192 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall 2X6 Back 180 1 200 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Right Wall 2X6 Right 270 1 157.5 0.29 NFRC 0.22 NFRC Bug Screen
Window 6 Window Front Wall Front 0 1 90 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 siding 24 0.142857
Door 2 Garage Wall 21.3 0.2
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 3 Left Wall 148 1
Door 4 Right Wall 84 1
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 10 0.1 10 10 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 3908 268 None 80%No
Slab 2 __Garage__405 40 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-13 Wall + R-4 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / R-4 0.068
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 9 45500 43000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 145 0.25 Default 0 n/a
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee Calculation Date/Time:2021-07-20T07:32:48-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:35:25
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:19:10
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:02
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115419B-000-000-0000000-0000 2021-07-21 14:16:02 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
GENERAL INFORMATION
01 Project Name Plan 3-The Jubilee_Opt Multi Gen Suite
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.3
18 Total Cond. Floor Area (ft
2)4134 19 Glazing Percentage (%)22.25%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 48.4 23.9
Proposed Designs
North Facing 45.2 23 3.2 0.9
East Facing 45.9 23.8 2.5 0.1
South Facing 45.9 23.8 2.5 0.1
West Facing 43.8 21.7 4.6 2.2
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 7.51 kWdc
•Proposed PV Capacity Scaling: North (7.47 kWdc) East (7.47 kWdc) South (7.47 kWdc) West (7.47 kWdc)
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.94 2.41 -0.47 -24.2
Space Cooling 86.16 77.53 8.63 10
IAQ Ventilation 2.16 2.16 0 0
Water Heating 5.17 4.68 0.49 9.5
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 95.43 86.78 8.65 9.1
Space Heating 1.94 2.41 -0.47 -24.2
Space Cooling 86.16 79.53 6.63 7.7
IAQ Ventilation 2.16 2.16 0 0
Water Heating 5.17 4.68 0.49 9.5
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 95.43 88.78 6.65 7
Space Heating 1.94 2.91 -0.97 -50
Space Cooling 86.16 78.9 7.26 8.4
IAQ Ventilation 2.16 2.16 0 0
Water Heating 5.17 4.68 0.49 9.5
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 95.43 88.65 6.78 7.1
Space Heating 1.94 2.63 -0.69 -35.6
Space Cooling 86.16 73.73 12.43 14.4
IAQ Ventilation 2.16 2.16 0 0
Water Heating 5.17 4.68 0.49 9.5
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 95.43 83.2 12.23 12.8
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
7.47 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3-The Jubilee_Opt Multi
Gen Suite
4134 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 4134 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 siding Home R-21 Wall 0 Front 321.9 135 90
Left Wall 2X4 Home R-13 Wall + R-4 90 Left 133.2 72 90
Left Wall 2X6 Home R-21 + R-4 90 Left 928.7 163.5 90
Rear Wall 2X4 Home R-13 Wall + R-4 180 Back 327.5 200 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 449.6 192 90
Right Wall 2X6 Home R-21 + R-4 270 Right 1068.4 181.5 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 455.1 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 n/a n/a 4134 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 455.1 45 90
Left Wall __Garage__R-0 Wall 90 Left 235.9 148 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 235.9 20 90
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 438 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 siding Front 0 1 111 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Wall 2X4 Left 90 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Left Wall 2X6 Left 90 1 163.5 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Rear Wall 2X4 Back 180 20 8 1 200 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall 2X6 Back 180 1 192 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Right Wall 2X6 Right 270 1 181.5 0.29 NFRC 0.22 NFRC Bug Screen
Window 6 Window Front Wall Front 0 1 45 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 siding 24 0.142857
Door 2 Garage Wall 21.3 0.2
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 3 Left Wall 148 1
Door 4 Right Wall 20 1
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 10 0.1 10 10 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 4134 291 None 80%No
Slab 2 __Garage__438 84 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-13 Wall + R-4 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / R-4 0.068
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 8.5 45500 43000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 151 0.25 Default 0 n/a
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3-The Jubilee_Opt Multi Gen Suite Calculation Date/Time:2021-07-20T07:40:28-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 3-The Jubilee_Opt Multi Gen Suite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:42:48
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:19:43
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:15
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115422B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
GENERAL INFORMATION
01 Project Name Plan 4- The Tecoma
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 3
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft
2)3024 19 Glazing Percentage (%)18.12%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 48.5 23.6
Proposed Designs
North Facing 43.5 21.4 5 2.2
East Facing 45.3 23.2 3.2 0.4
South Facing 45.7 23.6 2.8 0
West Facing 42.8 20.7 5.7 2.9
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 5.85 kWdc
•Proposed PV Capacity Scaling: North (5.73 kWdc) East (5.73 kWdc) South (5.73 kWdc) West (5.73 kWdc)
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.71 2.09 -0.38 -22.2
Space Cooling 86.76 73.02 13.74 15.8
IAQ Ventilation 2.21 2.21 0 0
Water Heating 6.61 6.01 0.6 9.1
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 97.29 83.33 13.96 14.3
Space Heating 1.71 1.85 -0.14 -8.2
Space Cooling 86.76 78.27 8.49 9.8
IAQ Ventilation 2.21 2.21 0 0
Water Heating 6.61 6.01 0.6 9.1
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 97.29 88.34 8.95 9.2
Space Heating 1.71 2.59 -0.88 -51.5
Space Cooling 86.76 78.5 8.26 9.5
IAQ Ventilation 2.21 2.21 0 0
Water Heating 6.61 6.01 0.6 9.1
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 97.29 89.31 7.98 8.2
Space Heating 1.71 2.55 -0.84 -49.1
Space Cooling 86.76 70.53 16.23 18.7
IAQ Ventilation 2.21 2.21 0 0
Water Heating 6.61 6.01 0.6 9.1
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 97.29 81.3 15.99 16.4
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
5.73 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 4- The Tecoma 3024 1 3 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 3024 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 Home R-21 + R-4 0 Front 61.1 24 90
Front Wall 2X6 siding Home R-21 Wall 0 Front 255.3 36 90
Left Wall 2X6 Home R-21 + R-4 90 Left 815 192 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 555 256 90
Right Wall 2X6 Home R-21 + R-4 270 Right 366.3 64 90
Right Wall 2X6 siding Home R-21 Wall 270 Right 94.4 0 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 621.6 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 3024 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 238.7 128 90
Left Wall __Garage__R-0 Wall 90 Left 77.7 0 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 460.7 0 90
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 671 0 4 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 siding Front 0 1 36 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Wall 2X6 Left 90 1 192 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2X6 Back 180 1 96 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Rear Wall 2X6 Back 180 20 8 1 160 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Wall 2X6 Right 270 1 64 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 24 0.142857
Door 2 Garage Wall 21.3 0.2
Door 3 Front Wall 128 1
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 10 1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 3024 196 None 80%No
Slab 2 __Garage__671 70 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 8.5 38000 36000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 113 0.25 Default 0 n/a
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4- The Tecoma Calculation Date/Time:2021-07-20T07:47:01-07:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4-The Tecoma.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:49:33
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:20:16
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:15
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115427B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 1 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
GENERAL INFORMATION
01 Project Name Plan 4X-The Tacoma Elite
02 Run Title Title 24 Analysis
03 Project Location Stone Creek
04 City La Quinta 05 Standards Version 2019
06 Zip code 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 2
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft
2)4013 19 Glazing Percentage (%)19.91%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 2 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 47.8 23.3
Proposed Designs
North Facing 44.4 21.7 3.4 1.6
East Facing 44.9 22.2 2.9 1.1
South Facing 46.1 23.3 1.7 0
West Facing 43.2 20.5 4.6 2.8
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 7.94 kWdc
•Proposed PV Capacity Scaling: North (8.14 kWdc) East (8.14 kWdc) South (8.14 kWdc) West (8.14 kWdc)
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 3 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.36 2.84 -0.48 -20.3
Space Cooling 91.07 81.16 9.91 10.9
IAQ Ventilation 2.18 2.18 0 0
Water Heating 5.86 5.29 0.57 9.7
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 101.47 91.47 10 9.9
Space Heating 2.36 2.64 -0.28 -11.9
Space Cooling 91.07 82.81 8.26 9.1
IAQ Ventilation 2.18 2.18 0 0
Water Heating 5.86 5.29 0.57 9.7
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 101.47 92.92 8.55 8.4
Space Heating 2.36 3.3 -0.94 -39.8
Space Cooling 91.07 85.4 5.67 6.2
IAQ Ventilation 2.18 2.18 0 0
Water Heating 5.86 5.29 0.57 9.7
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 101.47 96.17 5.3 5.2
Space Heating 2.36 3.22 -0.86 -36.4
Space Cooling 91.07 77.21 13.86 15.2
IAQ Ventilation 2.18 2.18 0 0
Water Heating 5.86 5.29 0.57 9.7
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 101.47 87.9 13.57 13.4
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 4 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
8.14 NA Premium Fixed (roof
mount)Microinverters true 105-300 n/a n/a <=7:12 96 97
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 5 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 4X-The Tacoma Elite 4013 1 5 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC1 4013 11.1 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Wall 2X6 Home R-21 + R-4 0 Front 238.7 36 90
Front Wall 2X6 siding Home R-21 Wall 0 Front 77.7 24 90
Left Wall 2X6 Home R-21 + R-4 90 Left 843.6 192 90
Rear Wall 2X6 Home R-21 + R-4 180 Back 555 256 90
Right Wall 2X6 Home R-21 + R-4 270 Right 460.7 64 90
Front Wall 2X6 2 Home R-21 + R-4 0 Front 221 12 90
Front Wall 2X6 siding 2 Home R-21 Wall 0 Front 135.8 15 90
Left Wall 2X6 2 Home R-21 + R-4 90 Left 313.6 117 90
Rear Wall 2X6 2 Home R-21 + R-4 180 Back 356.8 32 90
Right Wall 2X6 2 Home R-21 + R-4 270 Right 313.8 75 90
Garage Wall Home>>__Garage__R-21 Wall1 n/a n/a 621.6 21.3 n/a
Roof 2 Home R-0 Roof Attic + R-30 BD n/a n/a 2035 n/a n/a
Roof 3 Home R-0 Roof Attic + R-30 BD n/a n/a 3024 n/a n/a
Front Wall __Garage__R-0 Wall 0 Front 238.7 128 90
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 6 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Left Wall __Garage__R-0 Wall 90 Left 77.7 16.7 90
Rear Wall __Garage__R-0 Wall 180 Back 0.1 0 90
Right Wall __Garage__R-0 Wall 270 Right 460.2 0 90
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft
2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__R-0 Roof No
Attic 0 Front 671 0 0 0.16 0.92 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Home Attic RoofHome Unventilated 4 0.16 0.92 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Wall 2X6 Front 0 1 36 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Wall 2X6 Left 90 1 192 0.29 NFRC 0.22 NFRC Bug Screen
Window OH Window Rear Wall 2X6 Back 180 20 8 1 160 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2X6 Back 180 1 96 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Wall 2X6 Right 270 1 64 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Front Wall 2X6 2 Front 0 1 12 0.29 NFRC 0.22 NFRC Bug Screen
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 7 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window 6 Window Front Wall 2X6 siding 2 Front 0 1 15 0.29 NFRC 0.22 NFRC Bug Screen
Window 7 Window Left Wall 2X6 2 Left 90 1 45 0.29 NFRC 0.22 NFRC Bug Screen
Window OH 2 Window Left Wall 2X6 2 Left 90 9 8 1 72 0.29 NFRC 0.22 NFRC Bug Screen
Window 8 Window Rear Wall 2X6 2 Back 180 1 8 0.29 NFRC 0.22 NFRC Bug Screen
Window 9 Window Rear Wall 2X6 2 Back 180 1 24 0.29 NFRC 0.22 NFRC Bug Screen
Window 10 Window Right Wall 2X6 2 Right 270 1 75 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Wall 2X6 siding 24 0.142857
Door 2 Garage Wall 21.3 0.181818
Door 3 Front Wall 128 1
Door 4 Left Wall 16.7 0.2
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window OH 12 1 2 2 0 0 0 0 0 0 0 0 0
Window OH 2 12 1 2 2 0 0 0 0 0 0 0 0 0
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 8 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab Home 3024 196 None 80%No
Slab 2 __Garage__671 70 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 + R-4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-0 Roof No Attic Cathedral Ceilings
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-21 Wall1 Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 9 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / None 0.032
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-17.0 insul.
R-0 Roof Attic + R-30 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 10 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 2 8.5 54500 51000 16 13 Zonally
Controlled
Single
Speed
Heat Pump System
1-hers-htpump
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 11 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 275 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.58 HVAC Fan 1-hers-fan
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 12 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 149 0.25 Default 0 n/a
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4X-The Tacoma Elite Calculation Date/Time:2021-07-20T07:56:00-07:00 (Page 13 of 13)
Calculation Description:Title 24 Analysis Input File Name:Toll Brothers_Plan 4X-The Tecoma Elite.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-20 07:59:12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-21 09:20:48
R16-18-20136
702-365-8080
Allen Janisch
Toll Brothers, Inc. - Palm Springs
14350 N. 87th St, #310
Scottsdale, AZ 85260
2021-07-21 14:16:15
na
760-770-0707 101
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010115428B-000-000-0000000-0000 2021-07-21 14:16:15 CalCERTS inc.