BSOL2021-0213- Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 1 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
GENERAL INFORMATION
01 Project Name Lot 30 Madison Club
02 Run Title Title 24 Analysis
03 Project Location 53335 Ross Avenue
04 City LaQuinta 05 Standards Version 2019
06 Zip code 92253 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)45
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2
16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.37
18 Total Cond. Floor Area (ft2)17194 19 Glazing Percentage (%)19.26%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 2 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
ENERGY DESIGN RATING
Energy Design Ratings Compliance Margins
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 34.4 18.7
Proposed Design 30.6 16.1 3.8 2.6
RESULT:3:COMPLIES
1: Efficiency EDR includes improvements to the building envelope and more efficient equipment
2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
3: Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 16.30 kWdc
ENERGY USE SUMMARY
Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.99 3.88 -0.89 -29.8
Space Cooling 60.04 50.49 9.55 15.9
IAQ Ventilation 1.69 1.69 0 0
Water Heating 1.37 1.94 -0.57 -41.6
Self Utilization Credit n/a 0 0 n/a
Compliance Energy Total 66.09 58 8.09 12.2
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)Inverter Eff.
(%)
Annual
Solar Access
(%)
15 NA Premium Fixed (roof
mount)Microinverters false 181 Degre
es 5 1.05 98.3 100
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 3 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Cool roof
•Insulation above roof deck
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•Pipe Insulation, All Lines
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Lot 30 Madison Club 17194 1 5 12 0 1
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 4 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Zone 1 Conditioned HVAC System 11 781 10 DHW Sys 1 N/A
Zone 2 Conditioned HVAC System 22 745 10 DHW Sys 1 N/A
Zone 5 Conditioned HVAC System 53 2125 10 DHW Sys 1 N/A
Zone 6 Conditioned HVAC System 64 3334 10 DHW Sys 1 N/A
Zone7 Conditioned HVAC System 75 3177 10 DHW Sys 1 N/A
Zone 8 Conditioned HVAC System 86 768 10 DHW Sys 1 N/A
Zone10 Conditioned HVAC System 107 2962 10 DHW Sys 1 N/A
Zone 11 Conditioned HVAC System 118 1210 10 DHW Sys 1 N/A
Zone 3 Conditioned HVAC System 39 690 10 DHW Sys 1 N/A
Zone 4 Conditioned HVAC System 410 698 10 DHW Sys 1 N/A
Zone 9 Conditioned HVAC System 911 560 10 DHW Sys 1 N/A
Zone 12 Conditioned HVAC System 1212 144 10 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Northwest Exterior
Wall Zone 1 R-21 Wall1 225 Back 612 133 90
Northwest Exterior
Wall 2 Zone 2 R-21 Wall1 315 Right 240 111 90
Southeast Exterior Wall Zone 5 R-21 Wall1 135 Left 480 0 90
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 5 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Northwest Exterior
Wall 3 Zone 5 R-21 Wall1 315 Right 360 72 90
Northeast Exterior Wall Zone 5 R-21 Wall1 45 Front 720 72 90
Northeast Exterior Wall
2 Zone 6 R-21 Wall1 45 Front 480 220 90
Southwest Exterior
Wall Zone 6 R-21 Wall1 225 Back 788 588 90
Southeast Exterior Wall
2 Zone 6 R-21 Wall1 135 Left 480 220 90
Southeast Exterior Wall
3 Zone7 R-21 Wall1 135 Left 972 81 90
Southwestt Exterior
Wall Zone7 R-21 Wall1 225 Back 516 324 90
Southeast Exterior Wall
4 Zone 8 R-21 Wall1 135 Left 170 27 90
Northeast Etxterior
Wall Zone 8 R-21 Wall1 45 Front 552 0 90
Northwest Exterior
Wall 4 Zone 8 R-21 Wall1 315 Right 432 220 90
Southeast Exterior Wall
5 Zone10 R-21 Wall1 135 Left 804 0 90
Southwest Exterior
Wall 2 Zone10 R-21 Wall1 225 Back 960 0 90
Northwest Exterior
Wall 5 Zone10 R-21 Wall1 315 Right 792 440 90
Northeast Exterior Wall
3 Zone10 R-21 Wall1 45 Front 960 114 90
Southeast Exterior Wall
6 Zone 11 R-21 Wall1 135 Left 530 432.6 90
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 6 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Northeast Exterior Wall
4 Zone 11 R-21 Wall1 45 Front 276 0 90
Southwest Exterior
Wall 3 Zone 11 R-21 Wall1 225 Back 240 0 90
Northwest Exterior
Wall 6 Zone 3 R-21 Wall1 315 Right 317 133 90
Northwest Exterior
Wall 7 Zone 4 R-21 Wall1 315 Right 324 133 90
Southeast Exterior Wall
7 Zone 9 R-21 Wall1 135 Left 280 0 90
Southeast Exterior Wall
8 Zone 12 R-21 Wall1 135 Left 96 0 90
Roof 2 Zone 1 R-30 Roof Attic 6-30 n/a n/a 781 n/a n/a
Roof 3 Zone 2 R-30 Roof Attic 6-30 n/a n/a 745 n/a n/a
Roof 4 Zone 5 R-30 Roof Attic 6-30 n/a n/a 2125 n/a n/a
Roof 5 Zone7 R-30 Roof Attic 6-30 n/a n/a 3177 n/a n/a
Roof 6 Zone 8 R-30 Roof Attic 6-30 n/a n/a 768 n/a n/a
Roof 7 Zone10 R-30 Roof Attic 6-30 n/a n/a 2944 n/a n/a
Roof 8 Zone 11 R-30 Roof Attic 6-30 n/a n/a 1210 n/a n/a
Roof 9 Zone 3 R-30 Roof Attic 6-30 n/a n/a 690 n/a n/a
Roof 10 Zone 4 R-30 Roof Attic 6-30 n/a n/a 698 n/a n/a
Roof 11 Zone 9 R-30 Roof Attic 6-30 n/a n/a 560 n/a n/a
Roof 12 Zone 12 R-30 Roof Attic 6-30 n/a n/a 144 n/a n/a
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 7 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof Zone10 R-30 Roof Attic
6-301 315 n/a 18.1 18 0.2 0.79 0.9 Yes
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone7 Attic RoofZone7 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 8 Attic RoofZone 8 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone10 Attic RoofZone10 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 11 Attic RoofZone 11 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 3 Attic RoofZone 3 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 9 Attic RoofZone 9 Unventilated 0 0.79 0.9 Yes Yes
Attic Zone 12 Attic RoofZone 12 Unventilated 0 0.79 0.9 Yes Yes
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window W-09 Window Northwest Exterior Wall Back 225 1 12 0.24 NFRC 0.24 NFRC Bug Screen
Window D-36 Window Northwest Exterior Wall Back 225 11 11 1 121 0.32 NFRC 0.21 NFRC Bug Screen
Window D-34 Window Northwest Exterior Wall 2 Right 315 9 11 1 99 0.32 NFRC 0.21 NFRC Bug Screen
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 8 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window W-08 Window Northwest Exterior Wall 2 Right 315 1 12 0.24 NFRC 0.24 NFRC Bug Screen
Window D-18 Window Northwest Exterior Wall 3 Right 315 6 12 1 72 0.32 NFRC 0.21 NFRC Bug Screen
Window W-04 Window Northeast Exterior Wall Front 45 1 15 0.24 NFRC 0.24 NFRC Bug Screen
Window W-05 Window Northeast Exterior Wall Front 45 1 15 0.24 NFRC 0.24 NFRC Bug Screen
Window W-06 Window Northeast Exterior Wall Front 45 1 15 0.24 NFRC 0.24 NFRC Bug Screen
Window D-22 Window Northeast Exterior Wall Front 45 3 9 1 27 0.7 NFRC 0.7 NFRC Bug Screen
Window D-05 Window Northeast Exterior Wall 2 Front 45 20 11 1 220 0.32 NFRC 0.21 NFRC Bug Screen
Window D-17 Window Southwest Exterior Wall Back 225 49 12 1 588 0.32 NFRC 0.21 NFRC Bug Screen
Window D-04 Window Southeast Exterior Wall 2 Left 135 1 220 0.32 NFRC 0.21 NFRC Bug Screen
Window W-1 Window Southeast Exterior Wall 3 Left 135 1 18 0.24 NFRC 0.24 NFRC Bug Screen
Window W-2 Window Southeast Exterior Wall 3 Left 135 1 18 0.24 NFRC 0.24 NFRC Bug Screen
Window W-3 Window Southeast Exterior Wall 3 Left 135 1 18 0.24 NFRC 0.24 NFRC Bug Screen
Window D-15 Window Southwestt Exterior Wall Back 225 27 12 1 324 0.32 NFRC 0.21 NFRC Bug Screen
Window D-42 Window Southeast Exterior Wall 4 Left 135 1 27 0.34 NFRC 0.23 NFRC Bug Screen
Window D-06 Window Northwest Exterior Wall 4 Right 315 20 11 1 220 0.32 NFRC 0.21 NFRC Bug Screen
Window D-206 Window Northwest Exterior Wall 5 Right 315 1 90 0.32 NFRC 0.21 NFRC Bug Screen
Window D-207 Window Northwest Exterior Wall 5 Right 315 1 350 0.32 NFRC 0.21 NFRC Bug Screen
Window W-201 Window Northeast Exterior Wall 3 Front 45 1 30 0.24 NFRC 0.24 NFRC Bug Screen
Window W-202 Window Northeast Exterior Wall 3 Front 45 1 48 0.24 NFRC 0.24 NFRC Bug Screen
Window 203-1 Window Northeast Exterior Wall 3 Front 45 1 18 0.28 NFRC 0.23 NFRC Bug Screen
Window 203-2 Window Northeast Exterior Wall 3 Front 45 1 18 0.28 NFRC 0.23 NFRC Bug Screen
Window D-02 Window Southeast Exterior Wall 6 Left 135 1 216.3 0.71 Table
110.6-A 0.6
Table
110.6-
B
Bug Screen
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 9 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window D-03 Window Southeast Exterior Wall 6 Left 135 1 216.3 0.71 Table
110.6-A 0.6
Table
110.6-
B
Bug Screen
Window W-07 Window Northwest Exterior Wall 6 Right 315 1 12 0.24 NFRC 0.24 NFRC Bug Screen
Window D-27 Window Northwest Exterior Wall 6 Right 315 11 11 1 121 0.32 NFRC 0.21 NFRC Bug Screen
Window D-23 Window Northwest Exterior Wall 7 Right 315 11 11 1 121 0.32 NFRC 0.21 NFRC Bug Screen
Window W-10 Window Northwest Exterior Wall 7 Right 315 1 12 0.24 NFRC 0.24 NFRC Bug Screen
Skylight 204-1 Skylight Roof 0 1 9 0.57 NFRC 0.398 NFRC None
Skylight 204-2 Skylight Roof 0 1 9 0.57 NFRC 0.398 NFRC None
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door D-14 Southeast Exterior Wall 3 27 0.5
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window D-36 2 0.1 2 2 0 0 0 0 0 0 0 0 0
Window D-34 2 0.1 2 2 0 0 0 0 0 0 0 0 0
Window D-18 22 0.1 12 12 0 0 0 0 0 0 0 0 0
Window D-22 2 0.1 2 2 0 0 0 0 0 0 0 0 0
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 10 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window D-05 4 0.1 4 4 0 0 0 0 0 0 0 0 0
Window D-17 22 0.1 12 12 0 0 0 0 0 0 0 0 0
Window D-15 22 0.1 12 12 0 0 0 0 0 0 0 0 0
Window D-06 2 0.1 2 2 0 0 0 0 0 0 0 0 0
Window D-27 2 0.1 2 2 0 0 0 0 0 0 0 0 0
Window D-23 2 0.1 2 2 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade Zone 1 781 25 None 100%No
Slab-on-Grade 2 Zone 2 745 12 None 100%No
Slab-on-Grade 3 Zone 5 2125 0.1 None 80%No
Slab-on-Grade 4 Zone 6 3334 20 None 100%No
Slab-on-Grade 5 Zone7 3177 80 None 100%No
Slab-on-Grade 6 Zone 8 768 30 None 100%No
Slab-on-Grade 7 Zone 11 1210 90 None 100%No
Slab-on-Grade 8 Zone 3 690 30 None 100%No
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 11 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade 9 Zone 4 698 30 None 100%No
Slab-on-Grade 10 Zone 9 560 10 None 100%No
Slab-on-Grade 11 Zone 12 144 12 None 100%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall1 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-30 Roof Attic 6-301 Cathedral Ceilings Wood Framed
Ceiling 2x12 @ 24 in. O. C.R-0 R-30 / R-6 0.026
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x12
Sheathing / Insulation: R-30 Sheathing
Inside Finish: Gypsum Board
R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
R-30 Wall Interior Walls Wood Framed Wall 2x8 @ 16 in. O. C.R-30 None / None 0.049
Inside Finish: Gypsum Board
Cavity / Frame: R-30 / 2x8
Other Side Finish: Gypsum Board
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 12 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofZone 1 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 2 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 5 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone7 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 8 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 13 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofZone10 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 11 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 3 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 4 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
Attic RoofZone 9 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 14 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofZone 12 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031
Roofing: Light Roof (Asphalt Shingle)
Above Deck Insulation: R-6 Sheathing
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
R-30 Roof Attic 6-30 Ceilings (below
attic)
Wood Framed
Ceiling 2x12 @ 24 in. O. C.R-0 None / None 0.474 Cavity / Frame: no insul. / 2x12
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 11462.7
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1 Domestic Hot Water
(DHW)
HERS Verified Pipe
Insulation credit DHW Heater 1 (1)n/a None DHW Sys 1-hers-dhw
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 15 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type #
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Commercial
Storage 1 75 0.8-TE 85000-
Btu/Hr 0 0.020000 n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Heating Unit
Name
Cooling Unit
Name Fan Name Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System 11 Heat pump heating cooling Heat Pump
System 1
Heat Pump
System 1 HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
HVAC System 22 Heat pump heating cooling Heat Pump
System 2
Heat Pump
System 2 HVAC Fan 2
Air
Distribution
System 2
Setback New NA 1 1
HVAC System 53 Heat pump heating cooling Heat Pump
System 3
Heat Pump
System 3 HVAC Fan 3
Air
Distribution
System 3
Setback New NA 2 2
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 16 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Heating Unit
Name
Cooling Unit
Name Fan Name Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System 64 Heat pump heating cooling Heat Pump
System 4
Heat Pump
System 4 HVAC Fan 4
Air
Distribution
System 4
Setback New NA 2 2
HVAC System 75 Heat pump heating cooling Heat Pump
System 5
Heat Pump
System 5 HVAC Fan 5
Air
Distribution
System 5
Setback New NA 2 2
HVAC System 86 Heat pump heating cooling Heat Pump
System 6
Heat Pump
System 6 HVAC Fan 6
Air
Distribution
System 6
Setback New NA 1 1
HVAC System 107 Heat pump heating cooling Heat Pump
System 7
Heat Pump
System 7 HVAC Fan 7
Air
Distribution
System 7
Setback New NA 2 2
HVAC System 118 Heat pump heating cooling Heat Pump
System 8
Heat Pump
System 8 HVAC Fan 8
Air
Distribution
System 8
Setback New NA 1 1
HVAC System 39 Heat pump heating cooling Heat Pump
System 9
Heat Pump
System 9 HVAC Fan 9
Air
Distribution
System 9
Setback New NA 1 1
HVAC System 410 Heat pump heating cooling Heat Pump
System 10
Heat Pump
System 10 HVAC Fan 10
Air
Distribution
System 10
Setback New NA 1 1
HVAC System 911 Heat pump heating cooling Heat Pump
System 11
Heat Pump
System 11 HVAC Fan 11
Air
Distribution
System 11
Setback New NA 1 1
HVAC System 1212 Heat pump heating cooling Heat Pump
System 12
Heat Pump
System 12 HVAC Fan 12
Air
Distribution
System 12
Setback New NA 1 1
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 17 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi-
speed
Heat Pump System
1-hers-htpump
Heat Pump System 2 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi-
speed
Heat Pump System
2-hers-htpump
Heat Pump System 3 Central split HP 2 10.5 45000 42500 22 13 Not Zonal Single
Speed
Heat Pump System
3-hers-htpump
Heat Pump System 4 Central split HP 2 11 59000 49500 21 13 Not Zonal Multi-
speed
Heat Pump System
4-hers-htpump
Heat Pump System 5 Central split HP 2 11 59000 49500 21 13 Not Zonal Multi-
speed
Heat Pump System
5-hers-htpump
Heat Pump System 6 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi-
speed
Heat Pump System
6-hers-htpump
Heat Pump System 7 Central split HP 2 11 59000 49500 21 13 Not Zonal Single
Speed
Heat Pump System
7-hers-htpump
Heat Pump System 8 Central split HP 1 10.5 34600 32870 21 13 Zonally
Controlled
Multi-
speed
Heat Pump System
8-hers-htpump
Heat Pump System 9 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi-
speed
Heat Pump System
9-hers-htpump
Heat Pump System
10 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi-
speed
Heat Pump System
10-hers-htpump
Heat Pump System
11 Central split HP 1 12 24000 22800 22 14 Zonally
Controlled
Multi-
speed
Heat Pump System
11-hers-htpump
Heat Pump System
12 Central split HP 1 8.3 10800 8730 21 13 Not Zonal Single
Speed
Heat Pump System
12-hers-htpump
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 18 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant
Charge Verified HSPF Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
2-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
3-hers-htpump Required 350 Required Required No Yes Yes Yes
Heat Pump System
4-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
5-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
6-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
7-hers-htpump Required 350 Required Required No Yes Yes Yes
Heat Pump System
8-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
9-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
10-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
11-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
12-hers-htpump Required 350 Required Required No Yes Yes Yes
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 19 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage HERS
Verification
Air Distribution
System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
Air Distribution
System 2 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
2-hers-dist
Air Distribution
System 3 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
3-hers-dist
Air Distribution
System 4 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
4-hers-dist
Air Distribution
System 5 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
5-hers-dist
Air Distribution
System 6 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
6-hers-dist
Air Distribution
System 7 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
7-hers-dist
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 20 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage HERS
Verification
Air Distribution
System 8 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
8-hers-dist
Air Distribution
System 9 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
9-hers-dist
Air Distribution
System 10 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
10-hers-dist
Air Distribution
System 11 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
11-hers-dist
Air Distribution
System 12 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
12-hers-dist
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 21 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 2-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 3-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 4-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 5-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 6-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 7-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 8-hers-dist Yes 3.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 9-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System
10-hers-dist
Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 22 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System
11-hers-dist
Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System
12-hers-dist
Yes 2.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.42 HVAC Fan 1-hers-fan
HVAC Fan 2 HVAC Fan 0.42 HVAC Fan 2-hers-fan
HVAC Fan 3 HVAC Fan 0.42 HVAC Fan 3-hers-fan
HVAC Fan 4 HVAC Fan 0.42 HVAC Fan 4-hers-fan
HVAC Fan 5 HVAC Fan 0.42 HVAC Fan 5-hers-fan
HVAC Fan 6 HVAC Fan 0.42 HVAC Fan 6-hers-fan
HVAC Fan 7 HVAC Fan 0.42 HVAC Fan 7-hers-fan
HVAC Fan 8 HVAC Fan 0.37 HVAC Fan 8-hers-fan
HVAC Fan 9 HVAC Fan 0.34 HVAC Fan 9-hers-fan
HVAC Fan 10 HVAC Fan 0.34 HVAC Fan 10-hers-fan
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 23 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 11 HVAC Fan 0.34 HVAC Fan 11-hers-fan
HVAC Fan 12 HVAC Fan 0.18 HVAC Fan 12-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.42
HVAC Fan 2-hers-fan Required 0.42
HVAC Fan 3-hers-fan Required 0.42
HVAC Fan 4-hers-fan Required 0.42
HVAC Fan 5-hers-fan Required 0.42
HVAC Fan 6-hers-fan Required 0.42
HVAC Fan 7-hers-fan Required 0.42
HVAC Fan 8-hers-fan Required 0.37
HVAC Fan 9-hers-fan Required 0.34
HVAC Fan 10-hers-fan Required 0.34
HVAC Fan 11-hers-fan Required 0.34
HVAC Fan 12-hers-fan Required 0.18
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 493 0.25 Default 0 n/a
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 24 of 24)
Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-08-02 15:03:52
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Butch White
Breeze Air Conditioning LLC 08/02/2021
75-145 Street Charles Place
Palm Desert, CA 92211 (760) 346-0855
Butch White
Breeze Air Conditioning LLC 08/02/2021
75-145 Street Charles Place 1045015
Palm Desert, CA 92211 (760) 346-0855
421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the
content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.