Loading...
BSOL2021-0213- Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 1 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 GENERAL INFORMATION 01 Project Name Lot 30 Madison Club 02 Run Title Title 24 Analysis 03 Project Location 53335 Ross Avenue 04 City LaQuinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)45 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 5 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.37 18 Total Cond. Floor Area (ft2)17194 19 Glazing Percentage (%)19.26% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 2 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 34.4 18.7 Proposed Design 30.6 16.1 3.8 2.6 RESULT:3:COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 16.30 kWdc ENERGY USE SUMMARY Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.99 3.88 -0.89 -29.8 Space Cooling 60.04 50.49 9.55 15.9 IAQ Ventilation 1.69 1.69 0 0 Water Heating 1.37 1.94 -0.57 -41.6 Self Utilization Credit n/a 0 0 n/a Compliance Energy Total 66.09 58 8.09 12.2 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12)Inverter Eff. (%) Annual Solar Access (%) 15 NA Premium Fixed (roof mount)Microinverters false 181 Degre es 5 1.05 98.3 100 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 3 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Insulation above roof deck •Insulation below roof deck •Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •Verified HSPF •Verified heat pump rated heating capacity HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •Pipe Insulation, All Lines BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 30 Madison Club 17194 1 5 12 0 1 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 4 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 11 781 10 DHW Sys 1 N/A Zone 2 Conditioned HVAC System 22 745 10 DHW Sys 1 N/A Zone 5 Conditioned HVAC System 53 2125 10 DHW Sys 1 N/A Zone 6 Conditioned HVAC System 64 3334 10 DHW Sys 1 N/A Zone7 Conditioned HVAC System 75 3177 10 DHW Sys 1 N/A Zone 8 Conditioned HVAC System 86 768 10 DHW Sys 1 N/A Zone10 Conditioned HVAC System 107 2962 10 DHW Sys 1 N/A Zone 11 Conditioned HVAC System 118 1210 10 DHW Sys 1 N/A Zone 3 Conditioned HVAC System 39 690 10 DHW Sys 1 N/A Zone 4 Conditioned HVAC System 410 698 10 DHW Sys 1 N/A Zone 9 Conditioned HVAC System 911 560 10 DHW Sys 1 N/A Zone 12 Conditioned HVAC System 1212 144 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Northwest Exterior Wall Zone 1 R-21 Wall1 225 Back 612 133 90 Northwest Exterior Wall 2 Zone 2 R-21 Wall1 315 Right 240 111 90 Southeast Exterior Wall Zone 5 R-21 Wall1 135 Left 480 0 90 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 5 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Northwest Exterior Wall 3 Zone 5 R-21 Wall1 315 Right 360 72 90 Northeast Exterior Wall Zone 5 R-21 Wall1 45 Front 720 72 90 Northeast Exterior Wall 2 Zone 6 R-21 Wall1 45 Front 480 220 90 Southwest Exterior Wall Zone 6 R-21 Wall1 225 Back 788 588 90 Southeast Exterior Wall 2 Zone 6 R-21 Wall1 135 Left 480 220 90 Southeast Exterior Wall 3 Zone7 R-21 Wall1 135 Left 972 81 90 Southwestt Exterior Wall Zone7 R-21 Wall1 225 Back 516 324 90 Southeast Exterior Wall 4 Zone 8 R-21 Wall1 135 Left 170 27 90 Northeast Etxterior Wall Zone 8 R-21 Wall1 45 Front 552 0 90 Northwest Exterior Wall 4 Zone 8 R-21 Wall1 315 Right 432 220 90 Southeast Exterior Wall 5 Zone10 R-21 Wall1 135 Left 804 0 90 Southwest Exterior Wall 2 Zone10 R-21 Wall1 225 Back 960 0 90 Northwest Exterior Wall 5 Zone10 R-21 Wall1 315 Right 792 440 90 Northeast Exterior Wall 3 Zone10 R-21 Wall1 45 Front 960 114 90 Southeast Exterior Wall 6 Zone 11 R-21 Wall1 135 Left 530 432.6 90 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 6 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Northeast Exterior Wall 4 Zone 11 R-21 Wall1 45 Front 276 0 90 Southwest Exterior Wall 3 Zone 11 R-21 Wall1 225 Back 240 0 90 Northwest Exterior Wall 6 Zone 3 R-21 Wall1 315 Right 317 133 90 Northwest Exterior Wall 7 Zone 4 R-21 Wall1 315 Right 324 133 90 Southeast Exterior Wall 7 Zone 9 R-21 Wall1 135 Left 280 0 90 Southeast Exterior Wall 8 Zone 12 R-21 Wall1 135 Left 96 0 90 Roof 2 Zone 1 R-30 Roof Attic 6-30 n/a n/a 781 n/a n/a Roof 3 Zone 2 R-30 Roof Attic 6-30 n/a n/a 745 n/a n/a Roof 4 Zone 5 R-30 Roof Attic 6-30 n/a n/a 2125 n/a n/a Roof 5 Zone7 R-30 Roof Attic 6-30 n/a n/a 3177 n/a n/a Roof 6 Zone 8 R-30 Roof Attic 6-30 n/a n/a 768 n/a n/a Roof 7 Zone10 R-30 Roof Attic 6-30 n/a n/a 2944 n/a n/a Roof 8 Zone 11 R-30 Roof Attic 6-30 n/a n/a 1210 n/a n/a Roof 9 Zone 3 R-30 Roof Attic 6-30 n/a n/a 690 n/a n/a Roof 10 Zone 4 R-30 Roof Attic 6-30 n/a n/a 698 n/a n/a Roof 11 Zone 9 R-30 Roof Attic 6-30 n/a n/a 560 n/a n/a Roof 12 Zone 12 R-30 Roof Attic 6-30 n/a n/a 144 n/a n/a 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 7 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Zone10 R-30 Roof Attic 6-301 315 n/a 18.1 18 0.2 0.79 0.9 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.79 0.9 Yes Yes Attic Zone7 Attic RoofZone7 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 8 Attic RoofZone 8 Unventilated 0 0.79 0.9 Yes Yes Attic Zone10 Attic RoofZone10 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 11 Attic RoofZone 11 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 3 Attic RoofZone 3 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 9 Attic RoofZone 9 Unventilated 0 0.79 0.9 Yes Yes Attic Zone 12 Attic RoofZone 12 Unventilated 0 0.79 0.9 Yes Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window W-09 Window Northwest Exterior Wall Back 225 1 12 0.24 NFRC 0.24 NFRC Bug Screen Window D-36 Window Northwest Exterior Wall Back 225 11 11 1 121 0.32 NFRC 0.21 NFRC Bug Screen Window D-34 Window Northwest Exterior Wall 2 Right 315 9 11 1 99 0.32 NFRC 0.21 NFRC Bug Screen 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 8 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window W-08 Window Northwest Exterior Wall 2 Right 315 1 12 0.24 NFRC 0.24 NFRC Bug Screen Window D-18 Window Northwest Exterior Wall 3 Right 315 6 12 1 72 0.32 NFRC 0.21 NFRC Bug Screen Window W-04 Window Northeast Exterior Wall Front 45 1 15 0.24 NFRC 0.24 NFRC Bug Screen Window W-05 Window Northeast Exterior Wall Front 45 1 15 0.24 NFRC 0.24 NFRC Bug Screen Window W-06 Window Northeast Exterior Wall Front 45 1 15 0.24 NFRC 0.24 NFRC Bug Screen Window D-22 Window Northeast Exterior Wall Front 45 3 9 1 27 0.7 NFRC 0.7 NFRC Bug Screen Window D-05 Window Northeast Exterior Wall 2 Front 45 20 11 1 220 0.32 NFRC 0.21 NFRC Bug Screen Window D-17 Window Southwest Exterior Wall Back 225 49 12 1 588 0.32 NFRC 0.21 NFRC Bug Screen Window D-04 Window Southeast Exterior Wall 2 Left 135 1 220 0.32 NFRC 0.21 NFRC Bug Screen Window W-1 Window Southeast Exterior Wall 3 Left 135 1 18 0.24 NFRC 0.24 NFRC Bug Screen Window W-2 Window Southeast Exterior Wall 3 Left 135 1 18 0.24 NFRC 0.24 NFRC Bug Screen Window W-3 Window Southeast Exterior Wall 3 Left 135 1 18 0.24 NFRC 0.24 NFRC Bug Screen Window D-15 Window Southwestt Exterior Wall Back 225 27 12 1 324 0.32 NFRC 0.21 NFRC Bug Screen Window D-42 Window Southeast Exterior Wall 4 Left 135 1 27 0.34 NFRC 0.23 NFRC Bug Screen Window D-06 Window Northwest Exterior Wall 4 Right 315 20 11 1 220 0.32 NFRC 0.21 NFRC Bug Screen Window D-206 Window Northwest Exterior Wall 5 Right 315 1 90 0.32 NFRC 0.21 NFRC Bug Screen Window D-207 Window Northwest Exterior Wall 5 Right 315 1 350 0.32 NFRC 0.21 NFRC Bug Screen Window W-201 Window Northeast Exterior Wall 3 Front 45 1 30 0.24 NFRC 0.24 NFRC Bug Screen Window W-202 Window Northeast Exterior Wall 3 Front 45 1 48 0.24 NFRC 0.24 NFRC Bug Screen Window 203-1 Window Northeast Exterior Wall 3 Front 45 1 18 0.28 NFRC 0.23 NFRC Bug Screen Window 203-2 Window Northeast Exterior Wall 3 Front 45 1 18 0.28 NFRC 0.23 NFRC Bug Screen Window D-02 Window Southeast Exterior Wall 6 Left 135 1 216.3 0.71 Table 110.6-A 0.6 Table 110.6- B Bug Screen 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 9 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window D-03 Window Southeast Exterior Wall 6 Left 135 1 216.3 0.71 Table 110.6-A 0.6 Table 110.6- B Bug Screen Window W-07 Window Northwest Exterior Wall 6 Right 315 1 12 0.24 NFRC 0.24 NFRC Bug Screen Window D-27 Window Northwest Exterior Wall 6 Right 315 11 11 1 121 0.32 NFRC 0.21 NFRC Bug Screen Window D-23 Window Northwest Exterior Wall 7 Right 315 11 11 1 121 0.32 NFRC 0.21 NFRC Bug Screen Window W-10 Window Northwest Exterior Wall 7 Right 315 1 12 0.24 NFRC 0.24 NFRC Bug Screen Skylight 204-1 Skylight Roof 0 1 9 0.57 NFRC 0.398 NFRC None Skylight 204-2 Skylight Roof 0 1 9 0.57 NFRC 0.398 NFRC None OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door D-14 Southeast Exterior Wall 3 27 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-36 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-34 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-18 22 0.1 12 12 0 0 0 0 0 0 0 0 0 Window D-22 2 0.1 2 2 0 0 0 0 0 0 0 0 0 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 10 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-05 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-17 22 0.1 12 12 0 0 0 0 0 0 0 0 0 Window D-15 22 0.1 12 12 0 0 0 0 0 0 0 0 0 Window D-06 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-27 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window D-23 2 0.1 2 2 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Zone 1 781 25 None 100%No Slab-on-Grade 2 Zone 2 745 12 None 100%No Slab-on-Grade 3 Zone 5 2125 0.1 None 80%No Slab-on-Grade 4 Zone 6 3334 20 None 100%No Slab-on-Grade 5 Zone7 3177 80 None 100%No Slab-on-Grade 6 Zone 8 768 30 None 100%No Slab-on-Grade 7 Zone 11 1210 90 None 100%No Slab-on-Grade 8 Zone 3 690 30 None 100%No 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 11 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade 9 Zone 4 698 30 None 100%No Slab-on-Grade 10 Zone 9 560 10 None 100%No Slab-on-Grade 11 Zone 12 144 12 None 100%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-21 Wall1 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco R-30 Roof Attic 6-301 Cathedral Ceilings Wood Framed Ceiling 2x12 @ 24 in. O. C.R-0 R-30 / R-6 0.026 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x12 Sheathing / Insulation: R-30 Sheathing Inside Finish: Gypsum Board R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board R-30 Wall Interior Walls Wood Framed Wall 2x8 @ 16 in. O. C.R-30 None / None 0.049 Inside Finish: Gypsum Board Cavity / Frame: R-30 / 2x8 Other Side Finish: Gypsum Board 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 12 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofZone 1 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 2 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 5 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone7 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 8 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 13 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofZone10 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 11 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 3 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 4 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. Attic RoofZone 9 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 14 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofZone 12 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-30 None / R-6 0.031 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-17.0 insul. R-30 Roof Attic 6-30 Ceilings (below attic) Wood Framed Ceiling 2x12 @ 24 in. O. C.R-0 None / None 0.474 Cavity / Frame: no insul. / 2x12 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 11462.7 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Pipe Insulation credit DHW Heater 1 (1)n/a None DHW Sys 1-hers-dhw 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 15 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Commercial Storage 1 75 0.8-TE 85000- Btu/Hr 0 0.020000 n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 11 Heat pump heating cooling Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC System 22 Heat pump heating cooling Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 Setback New NA 1 1 HVAC System 53 Heat pump heating cooling Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 Setback New NA 2 2 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 16 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 64 Heat pump heating cooling Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 Setback New NA 2 2 HVAC System 75 Heat pump heating cooling Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 Setback New NA 2 2 HVAC System 86 Heat pump heating cooling Heat Pump System 6 Heat Pump System 6 HVAC Fan 6 Air Distribution System 6 Setback New NA 1 1 HVAC System 107 Heat pump heating cooling Heat Pump System 7 Heat Pump System 7 HVAC Fan 7 Air Distribution System 7 Setback New NA 2 2 HVAC System 118 Heat pump heating cooling Heat Pump System 8 Heat Pump System 8 HVAC Fan 8 Air Distribution System 8 Setback New NA 1 1 HVAC System 39 Heat pump heating cooling Heat Pump System 9 Heat Pump System 9 HVAC Fan 9 Air Distribution System 9 Setback New NA 1 1 HVAC System 410 Heat pump heating cooling Heat Pump System 10 Heat Pump System 10 HVAC Fan 10 Air Distribution System 10 Setback New NA 1 1 HVAC System 911 Heat pump heating cooling Heat Pump System 11 Heat Pump System 11 HVAC Fan 11 Air Distribution System 11 Setback New NA 1 1 HVAC System 1212 Heat pump heating cooling Heat Pump System 12 Heat Pump System 12 HVAC Fan 12 Air Distribution System 12 Setback New NA 1 1 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 17 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi- speed Heat Pump System 1-hers-htpump Heat Pump System 2 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi- speed Heat Pump System 2-hers-htpump Heat Pump System 3 Central split HP 2 10.5 45000 42500 22 13 Not Zonal Single Speed Heat Pump System 3-hers-htpump Heat Pump System 4 Central split HP 2 11 59000 49500 21 13 Not Zonal Multi- speed Heat Pump System 4-hers-htpump Heat Pump System 5 Central split HP 2 11 59000 49500 21 13 Not Zonal Multi- speed Heat Pump System 5-hers-htpump Heat Pump System 6 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi- speed Heat Pump System 6-hers-htpump Heat Pump System 7 Central split HP 2 11 59000 49500 21 13 Not Zonal Single Speed Heat Pump System 7-hers-htpump Heat Pump System 8 Central split HP 1 10.5 34600 32870 21 13 Zonally Controlled Multi- speed Heat Pump System 8-hers-htpump Heat Pump System 9 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi- speed Heat Pump System 9-hers-htpump Heat Pump System 10 Central split HP 1 12 24000 22800 22 14 Not Zonal Multi- speed Heat Pump System 10-hers-htpump Heat Pump System 11 Central split HP 1 12 24000 22800 22 14 Zonally Controlled Multi- speed Heat Pump System 11-hers-htpump Heat Pump System 12 Central split HP 1 8.3 10800 8730 21 13 Not Zonal Single Speed Heat Pump System 12-hers-htpump 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 18 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 2-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 3-hers-htpump Required 350 Required Required No Yes Yes Yes Heat Pump System 4-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 5-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 6-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 7-hers-htpump Required 350 Required Required No Yes Yes Yes Heat Pump System 8-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 9-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 10-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 11-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 12-hers-htpump Required 350 Required Required No Yes Yes Yes 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 19 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist Air Distribution System 2 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 2-hers-dist Air Distribution System 3 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 3-hers-dist Air Distribution System 4 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 4-hers-dist Air Distribution System 5 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 5-hers-dist Air Distribution System 6 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 6-hers-dist Air Distribution System 7 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 7-hers-dist 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 20 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 8 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 8-hers-dist Air Distribution System 9 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 9-hers-dist Air Distribution System 10 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 10-hers-dist Air Distribution System 11 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 11-hers-dist Air Distribution System 12 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 12-hers-dist 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 21 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 2-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 3-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 4-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 5-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 6-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 7-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 8-hers-dist Yes 3.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 9-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 10-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 22 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 11-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 12-hers-dist Yes 2.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.42 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.42 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.42 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.42 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.42 HVAC Fan 5-hers-fan HVAC Fan 6 HVAC Fan 0.42 HVAC Fan 6-hers-fan HVAC Fan 7 HVAC Fan 0.42 HVAC Fan 7-hers-fan HVAC Fan 8 HVAC Fan 0.37 HVAC Fan 8-hers-fan HVAC Fan 9 HVAC Fan 0.34 HVAC Fan 9-hers-fan HVAC Fan 10 HVAC Fan 0.34 HVAC Fan 10-hers-fan 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 23 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 11 HVAC Fan 0.34 HVAC Fan 11-hers-fan HVAC Fan 12 HVAC Fan 0.18 HVAC Fan 12-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.42 HVAC Fan 2-hers-fan Required 0.42 HVAC Fan 3-hers-fan Required 0.42 HVAC Fan 4-hers-fan Required 0.42 HVAC Fan 5-hers-fan Required 0.42 HVAC Fan 6-hers-fan Required 0.42 HVAC Fan 7-hers-fan Required 0.42 HVAC Fan 8-hers-fan Required 0.37 HVAC Fan 9-hers-fan Required 0.34 HVAC Fan 10-hers-fan Required 0.34 HVAC Fan 11-hers-fan Required 0.34 HVAC Fan 12-hers-fan Required 0.18 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 493 0.25 Default 0 n/a 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Lot 30 Madison Club Calculation Date/Time:2021-08-02T14:59:58-07:00 (Page 24 of 24) Calculation Description:Title 24 Analysis Input File Name:Lot 30 Madison Club.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-08-02   15:03:52 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Butch White Breeze Air Conditioning LLC 08/02/2021 75-145 Street Charles Place Palm Desert, CA 92211 (760) 346-0855 Butch White Breeze Air Conditioning LLC 08/02/2021 75-145 Street Charles Place 1045015 Palm Desert, CA 92211 (760) 346-0855 421-P010113796A-000-000-0000000-0000 08/02/2021 15:02 CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.