Loading...
BPOL2021-0086BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 03/15/2021 ISSUED DATE: 03/19/2021 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 53335 ROSS AVE BPOL2021-0086 767680007 $523,803.00 Owner:SPRINGERS SPRINGERS 53370 ROSS AVENUE, LA QUINTA, CA 92253 Applicant:Craig Ernst 77-799 Jackal Drive Ste B, Palm Desert, CA 92211 Contractor:Craig Ernst / 820132 77-799 Jackal Drive Ste B, Palm Desert, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 5/6/25 2:40 pm Page 1 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2021-0086 53335 ROSS AVE BUILDING PERMIT SPRINGERS/ POOL,[2] SPAS, [4]FIRE PIT AND ENTRY WATER FEATUR *** SPRINGERS / POOL,SPA AND [1]GAS OUTLET AT REAR YARD. DETACHED SPA AT GAMEROOM COURT YARD. ENTRY WATER FEATURE AND [3] FIRE FEATURES. [SPIRE ENGINEERING] TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTIONTT FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. Use of Permit Construction Details 2Quantity of Detached Spa(s)/Water Feature(s) 3Number of Gas Outlet(s) Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BPOL2021-008 6 $26.83 GAS SYSTEM, 1-4 OUTLETS PC $26.83 $10.00 RECORDS MANAGEMENT FEE $10.00 $26.83 DEVICES, FIRST 20 PC $26.83 $201.25 SWIMMING POOL/SPA $201.25 $402.50 DETACHED SPA/WATER FEATURE/OTHER $402.50 $21.00 BSAS SB1473 FEE $21.00 $5.00 TECHNOLOGY ENHANCEMENT FEE $5.00 $26.83 DEVICES, FIRST 20 $26.83 $13.42 GAS SYSTEM, 1-4 OUTLETS $13.42 $109.48 SWIMMING POOL/SPA PC $109.48 $843.14 $843.14 Total for Invoice PERMIT-BPOL2021-0086 Grand Total for Permit $843.14 $843.14 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 03/15/2021 0:00 FINAL** v.2 Inspection FINAL** v.1 Inspection PRE-PLASTER v.1 Inspection DECK BOND v.1 Inspection UNDERGROUND GAS v.1 Inspection UNDERGROUND ELEC v.2 Inspection UNDERGROUND PLBG v.2 Inspection UNDERGROUND PLBG v.1 Inspection UNDERGROUND ELEC v.1 Inspection PRE-GUNITE v.1 Inspection Printed: 5/6/25 2:40 pm Page 2 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2021-0086 53335 ROSS AVE BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 5/6/25 2:40 pm Page 3 of 3 February 9, 2021 STRUCTURAL DESIGN CALCULATIONS Lot 30 Pool and Spas Project Description: 02.09.21 Spire Job #: 21SPR002 53335 Ross Avenue La Quinta, CA 92253 Provide structural engineering design for the main pool, spa, and indoor spa. 26461 Rancho Parkway South, Lake Forest, CA 92630 949.916.3440 www.spirestructures.com 03/18/2021J.ANAYA BPOL2021-0086 General:Sheet Table of Contents 1 Pool, Spa, and Water Feature: 4'-6" Max Depth Concrete Pool/Spa Design 2 6'-0" Max Depth Concrete Pool Design 3 Water Feature Wall Design 4-5 Appendix A: Geotechnical Reports Geotechnical update letter by Sladden Engineering A1-A5 Original geotechnical report by Sladden Engineering A6-A8 Table of Contents 1 Sheet: Calc By: Job: Date: 26461 Rancho Parkway South, Lake Forest, CA 92630 949.916.3440 www.spirestructures.com AGB 02/09/21 21SPR002 Lot 30 Pool & Spas Soils Report gsoil =110 pcf Soil weight qactive =35 pcf Lateral soil pressure qsurcharge =0 psf Surcharge load qseismic =0 plf Seismic load (working stress) SBall =1500 psf Soil bearing pressure per geotechnical report Pool Structural Properties gconc =150 pcf Concrete weight f'c =3.0 ksi Concrete strength fy =60.0 ksi Rebar yield stress H = 4.5 ft Height of pool tw =6.0 in Wall thickness d = 3.0 in Wall bar location ts =6.0 in Slab thickness Reinfvert =#3 @ 12 in As_vert =0.11 in2 / ft Reinfhoriz =#3 @ 12 in As_horiz =0.11 in2 / ft Service Loads on Wall Hb =0.4 k/ft Soil pressure Hs =0.0 k/ft Surcharge pressure HE =0.0 k/ft Seismic pressure Factored Loads for Concrete Design 1.6Hb =0.7 k/ft 1.6Hs =0.0 k/ft 1.4HE =0.0 k/ft Check Wall Flexure Capacity Mu =1.1 k-ft/ft Vu =0.7 k/ft f =0.90 flexure f =0.75 shear fMn =1.4 k-ft / ft fVn =3.0 Lbs / ft 4'-6" Max Depth Concrete Pool/Spa Design   -= )'85.0(212 9.0 c yy n fb AsFdAsFMf cnfbdV'2ff= 2 Sheet: Calc By: Job: Date: 26461 Rancho Parkway South, Lake Forest, CA 92630 949.916.3440 www.spirestructures.com AGB 02/09/21 21SPR002 Lot 30 Pool & Spas Soils Report gsoil =110 pcf Soil weight qactive =35 pcf Lateral soil pressure qsurcharge =0 psf Surcharge load qseismic =0 plf Seismic load (working stress) SBall =1500 psf Soil bearing pressure per geotechnical report Pool Structural Properties gconc =150 pcf Concrete weight f'c =3.0 ksi Concrete strength fy =60.0 ksi Rebar yield stress H = 6.0 ft Height of pool tw =8.0 in Wall thickness d = 3.0 in Wall bar location ts =6.0 in Slab thickness Reinfvert =#3 @ 6 in As_vert =0.22 in2 / ft Reinfhoriz =#3 @ 12 in As_horiz =0.11 in2 / ft Service Loads on Wall Hb =0.7 k/ft Soil pressure Hs =0.0 k/ft Surcharge pressure HE =0.0 k/ft Seismic pressure Factored Loads for Concrete Design 1.6Hb =1.2 k/ft 1.6Hs =0.0 k/ft 1.4HE =0.0 k/ft Check Wall Flexure Capacity Mu =2.4 k-ft/ft Vu =1.2 k/ft f =0.90 flexure f =0.75 shear fMn =2.8 k-ft / ft fVn =3.0 Lbs / ft 6'-0" Max Depth Concrete Pool Design   -= )'85.0(212 9.0 c yy n fb AsFdAsFMf cnfbdV'2ff= 3 Sheet: Calc By: Job: Date: 26461 Rancho Parkway South, Lake Forest, CA 92630 949.916.3440 www.spirestructures.com AGB 02/09/21 21SPR002 Lot 30 Pool & Spas Seismic Criteria Wind Criteria SDS =1.00 Vult =110 MPH Kz =0.85 (ASCE T29.3-1) Ip =1.0 Kzt =1.00 (ASCE 26.8.2) R = 1.25 Kd =0.85 (ASCE T26.6-1) Fp =100.0 psf Fw =26.6 psf (ult)G = 0.85 (Rigid per ASCE 26.9) Fp = SDS Ip /R Fw = qh G Cf As (E29.4-1)Cf =1.40 B/s=2, s/h=1 (F29.4-1) qh = 0.00256 Kz Kzt Kd V2 I =22.4 psf (E29.3-1) Stem Wall Design (Strength) t = 10.0 in = stem thickness W = 125 psf = unit wall weight Hs =17.0 ft = stem height (above grade) df =0.00 ft = depth to top of ftg Vu =1700 Lbs / ft = max(Fp,Fw)(Hs) Mu =14450 Lb ft / ft = Vu (Hs/2+df) d = 7.94 in f'c =3.0 ksi fy =60 ksi Vert = #6 svert =10 in Hor = #4 shor =12 in rvert =0.0044 rhor =0.0017 rtot =0.0061 As =0.53 in2 / ft a = 1.04 in = AsFy/[0.85f'c(12)] fflex =0.9 fshear =0.75 Mn = (AsFy)(d - a/2) fMn =17630 lb-ft / ft fVn =12385 lbs / ft DCRm =0.82 < 1 DCRv =0.14 < 1 Soil Bearing (ASD)SBall =3000 psf Stem 1 Stem 2 Stem 3 Soil Ftg t = 0.8 0.5 1.0 2.5 8.5 ft Thick h = 17.0 2.5 2.7 2.7 2.0 ft Height g =150.0 150.0 150.0 50.0 150.0 pcf Density W = 2125 188 401 334 2550 lbs Weight L = 0.4 2.3 5.5 7.3 4.3 ft Distance from toe MR =885 422 2203 2420 10838 lb-ft Resisting Moment Water Feature Wall (ASCE 7-16 CH 15, ACI 318-14) (See soils report) '75.14 cn vu u n fA dV MV          -= F REINF PP df Tf L 3" CLR 3" C L R Hs VERT RENIF HORIZ RENIF Tw d 4 Sheet: Calc By: Job: Date: 26461 Rancho Parkway South, Lake Forest, CA 92630 949.916.3440 www.spirestructures.com AGB 02/09/21 21SPR002 Lot 30 Pool & Spas Water Feature Wall (ASCE 7-16 CH 15, ACI 318-14) Mtot =16767 lb-ft Total reisting moment W tot =5597 lbs Total dead load e = 1.25 ft Eccentricty P = 1,973 lbs Implied load MD =2,474 lb-ft Moment from dead loads ME =12,750 lb-ft Moment from seismic wall loads D+E/1.4 0.9D+E/1.4 P = 5,597 5,037 lbs M = 15,224 14,976 lb-ft e = 2.72 2.97 ft L/6 = 1.42 1.42 ft SB = 2,439 2,630 psf DCR = 0.81 0.88 Sliding Design (ASD) Friction, m = 0.48 Passive = 300 pcf F = 1,190 Lbs = 0.7Fp·Hs F'FRICTION =2686 lbs = m·Wtot F'PASSIVE =600 lbs = Pass·Tf 2/2 F'TOTAL =2,886 Lbs = 1/3*F'FRICTION+F'PASSIVE FSslid =2.4 factor of safety > 1.1 (2019 CBC, Section 1807.2.3) 5 Sheet: Calc By: Job: Date: 26461 Rancho Parkway South, Lake Forest, CA 92630 949.916.3440 www.spirestructures.com AGB 02/09/21 21SPR002 Lot 30 Pool & Spas SHEET INDEXVICINITY MAP A CUSTOM POOL AND SPA FOR LOT 30 53-335 ROSS AVE, LA QUINTA, CA GENERAL NOTES TITLE SP-1.0 COVER SHEET SP-2.0 POOL SITE PLAN SP-3.0 ENLARGED POOL PLAN SP-3.1 POOL SECTIONS SP-3.2 ENLARGED POOL PLUMBING PLAN SP-4.0 INTERIOR SPA AND WATER FEATURE PLAN AND PLUMBING PLAN SP-5.0 EQUIPMENT LAYOUT AND SCHEDULE S-1 STRUCTURAL NOTES S-2 STRUCTURAL POOL DETAILS S-3 STRUCTURAL POOL DETAILS NO. ABBREVIATIONS REFERENCE SYMBOLS CITY OF LA QUINTA NOTES SHEET NO SHEET NO 14 1 SHEET NO F-1 J 01 GENERAL NOTES: 1. PROPOSED CONSTRUCTION WILL CONFORM TO THE CURRENT CODES (CBC 106.1.1) 2019 California Residential Code, Title 24 Part 2.5 2019 California Electrical Code, Title 24 Part 3 2019 California Mechanical Code, Title 24 Part 4 2019 California Plumbing Code, Title 24 Part 5 2019 California Energy Code, Title 24 Part 6 2019 California Fire Code, Title 24 Part 9 2. GOVERNMENT CODE SECTION 4216.2. (A) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR TO COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND, IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER SUITABLE MARKINGS THE AREA TO BE EXCAVATED. 3. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED WITH DELTAS TO BE SUBMITTED FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FIELD REVISIONS WARRANT SUCH A REQUEST. ELECTRICAL NOTES: 1. THE EQUIPMENT BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED SURFACES FOR 3 FEET HORIZONTALLY BEYOND THE INSIDE WALLS OF THE POOL. 2. ALL METAL-SHEATHED CABLES AND RACEWAYS, METAL PIPING, AND ALL FIXED METAL PARTS THAT ARE WITHIN THE FOLLOWING DISTANCES OF THE POOL, EXCEPT THOSE SEPARATED FROM THE POOL BY A PERMANENT BARRIER, SHALL BE BONDED: A.) WITHIN 5 FEET HORIZONTALLY OF THE INSIDE WALLS OF THE POOL. B.) WITHIN 12 FEET MEASURED VERTICALLY ABOVE THE MAXIMUM WATER LEVEL OF THE POOL, OR ANY SLIDES, DIVING BOARDS ETC... 3. PROVIDE 36" WORKING CLEARANCES FOR THE POOL EQUIPMENT DISCONNECT AND SUB PANEL (CEC ART 110.26) 4. LOAD CALCS - USE EXISTING ELECTRICAL FEED TO POOL EQUIPMENT 5. SINGLE LINE DIAGRAM - SEE BUILDING PERMIT AND APPROVED PLANS 6. NO OVERHEAD UTILITY/SERVICE LINES ARE IN THE VICINITY OF THE NEW POOL OR SPA 7. ALL OUTLETS SUPPLIED BY SINGLE PHASE, 15A AND 20A, 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION. THIS APPLIES TO OUTLETS REGARDLESS OF THEIR PROXIMITY TO THE SWIMMING POOL AND IT APPLIES TO CORD-AND-PLUG CONNECTED AND DIRECT CONNECTED SWIMMING POOL PUMP MOTORS. CEC 680.22 (B) MECHANICAL/PLUMBING NOTES: 1. ALL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. 2. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED. 3. GAS ISOMETRIC: - NEW 2" PE GAS LINE WITH TRACER WIRE, ±100 LINEAL FEET. 2019 ENERGY EFFICIENCY STANDARDS MANDATORY MEASURES (MF-1R) 1. ANY POOL OR SPA HEATING SYSTEM SHALL BE CERTIFIED TO HAVE: A THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AN ON-OFF SWITCH MOUNTED OUTSIDE OF THE HEATER; A PERMANENT WEATHERPROOF PLATE OR CARD WITH OPERATING INSTRUCTIONS; AND SHALL NOT USE ELECTRIC RESISTANCE HEATING OR A PILOT LIGHT. 2. ANY POOL OR SPA HEATING EQUIPMENT SHALL BE INSTALLED WITH AT LEAST 36" OF PIPE BETWEEN FILTER AND HEATER, OR DEDICATED SUCTION AND RETURN LINES, OR BUILT-UP CONNECTIONS FOR FUTURE SOLAR HEATING. 3. OUTDOOR POOLS OR SPAS THAT HAVE A HEAT PUMP OR GAS HEATER SHALL HAVE A COVER. 4. POOLS SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL WATER, AND A TIME SWITCH THAT WILL ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIODS. 5. RESIDENTIAL POOL SYSTEMS OR EQUIPMENT MUST MEET THE PUMP SIZING, FLOW RATE, PIPING AND FILTERS. EQUIPMENT NOTES/MANDATORY REQUIREMENTS 1. ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT MAY BE INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE SYSTEM OR EQUIPMENT HAS ALL OF THE FOLLOWING: EFFICIENCY - A THERMAL EFFICIENCY THAT COMPLIES WITH THE APPLIANCE EFFICIENCY REGULATIONS; AND ON-OFF SWITCH - A READILY ACCESSIBLE ON-OFF SWITCH, MOUNTED ON THE OUTSIDE OF THE HEATER THAT ALLOWS SHUTTING OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING; AND INSTRUCTIONS - A PERMANENT, EASILY READABLE , AND WEATHERPROOF PLATE OR CARD THAT GIVES INSTRUCTION FOR THE ENERGY EFFICIENT OPERATION OF THE POOL OR SPA HEATER AND FOR THE PROPER CARE OF POOL OR SPA WATER WHEN A COVER IS USED; AND ELECTRIC RESISTANCE HEATING - NO ELECTRIC RESISTANCE HEATING; AND 1.1.EXCEPTION 1 TO SECTION 114 (A)4: LISTED PACKAGE UNITS WITH FULLY INSULATED ENCLOSURE, AND WITH TIGHT-FITTING COVERS THAT ARE INSULATED TO AT LEAST R-6. 1.2.EXCEPTION 2 TO SECTION 114(A)4: POOLS OR SPAS DERIVING AT LEAST 60 PERCENT OF THE ANNUAL HEATING ENERGY FROM SITE SOLAR ENERGY OR RECOVERED ENERGY. 2. ANY POOL OR SPA SYSTEM OR EQUIPMENT SHALL BE INSTALLED WITH ALL OF THE FOLLOWING: PIPING - SEE MANDATORY MEASURES NOTE #2 COVERS - SEE MANDATORY MEASURES NOTE #3 DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS - SEE MANDATORY MEASURES NOTE #4 3. ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03 FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO FINAL INSPECTION APPROVAL, 4. DIRECTIONAL INLETS AND TIME SWITCHES FOR POOLS. IF THE SYSTEM OR EQUIPMENT IS FOR A POOL: 4.1.THE POOL SHALL HAVE DIRECTIONAL INLETS THAT ADEQUATELY MIX THE POOL WATER; AND 4.2.A TIME SWITCH OR SIMILAR CONTROL MECHANISM SHALL BE INSTALLED AS PART OF THE POOL WATER CIRCULATION CONTROL SYSTEM THAT WILL ALLOW ALL PUMPS TO BE SET OR PROGRAMMED TO RUN ONLY DURING OFF-PEAK ELECTRIC DEMAND PERIOD, AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. 5. ALL PUMPS AND PUMP MOTORS INSTALLED SHALL BE LISTED IN THE COMMISSIONS'S DIRECTORY OF CERTIFIED EQUIPMENT AND SHALL COMPLY WITH THE APPLIANCE EFFICIENCY REGULATIONS. 6. FILTRATION PUMPS SHALL BE SIZED, OR IF PROGRAMMABLE, SHALL BE PROGRAMMED, SO THAT THE FILTRATION FLOW RATE IS NOT GREATER THAN THE RATE NEEDED TO TURN OVER THE POOL WATER VOLUME IN 6 HOURS OR 36 GPM, WHICHEVER IS GREATER. 7. PUMP MOTORS USED FOR FILTRATION WITH A CAPACITY OF 1 HP OR MORE SHALL BE MULTI SPEED. 8. EACH AUXILIARY POOL LOAD SHALL BE SERVED BY EITHER SEPARATE PUMPS OR THE SYSTEM SHALL BE SERVED BY A MULTI SPEED PUMP. EXCEPTION - PUMPS LESS THAN 1 HP MAY BE SINGLE SPEED. 9. MULTI SPEED PUMPS SHALL HAVE CONTROLS WHICH DEFAULT TO THE FILTRATION FLOW RATE WHEN NO AUXILIARY POOL LOADS ARE OPERATING. 10. FOR MULTI SPEED PUMPS, THE CONTROLS SHALL DEFAULT TO THE FILTRATION FLOW SETTING WITHIN 24 HOURS AND SHALL HAVE AN OVERRIDE CAPABILITY FOR SERVICING. 11. A LENGTH OF STRAIGHT PIPE THAT IS GREATER THAN OR EQUAL TO AT LEAST 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE THE PUMP. 12. POOL PIPING SHALL BE SIZED SO THAT THE VELOCITY OF THE WATER AT MAXIMUM FLOW FOR AUXILIARY POOL LOADS DOES NOT EXCEED 8 FEET PER SECOND IN THE RETURN LINE AND 6 FEET PER SECOND IN THE SUCTION LINE. 13. ALL ELBOWS SHALL BE SWEEP ELBOWS OR ELBOW-TYPE THAT HAVE A PRESSURE DROP OF LESS THAN THE PRESSURE DROP OF STRAIGHT PIPE WITH A LENGTH OF 30 PIPE DIAMETERS. 14. FILTERS SHALL BE AT LEAST THE SIZE SPECIFIED IN NSF/ANSI 50 FOR PUBLIC POOL INTENDED. 15. MINIMUM DIAMETER OF BACKWASH VALVES SHALL BE 2 INCHES OF THE DIAMETER OF THE RETURN PIPE, WHICHEVER IS GREATER. SAFETY STANDARDS SECTION AV100.3 OF THE 2016 C.R.C. ADDRESSES THE POOL SAFETY STANDARDS FOR POOLS, SPAS AND HOT TUBS INSTALLED FOR SINGLE FAMILY RESIDENCE. FOR THE PURPOSE OF THIS CODE THE FOLLOWING DEFINITIONS ARE APPLICABLE: SWIMMING POOL: ANY STRUCTURE INTENDED FOR SWIMMING OR RECREATIONAL BATHING THAT CONTAINS WATER OVER 18 INCHES DEEP. ENCLOSURE: A FENCE, WALL, OR OTHER BARRIER THAT ISOLATES A SWIMMING POOL FROM ACCESS TO THE HOME ENCLOSURE REQUIREMENTS: AN OUTDOOR SWIMMING POOL, INCLUDING HOT TUBS OR SPAS SHALL BE SURROUNDED BY A BARRIER WHICH SHALL COMPLY WITH THE FOLLOWING: 1.TOP OF THE BARRIER SHALL BE AT LEAST 60 INCHES ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL 1.1.OPENINGS IN TECH BARRIER SHALL NOT ALLOW THE PASSAGE OF A 4 INCH DIA. SPHERE. 1.2.OPENING BETWEEN THE FINISH GRADE AND THE BOTTOM OF THE BARRIER SHALL BE MAX. 2 INCHES. 1.3.BARRIERS SHALL BE INSTALLED SO AS NOT HAVE ANY FEATURES WHICH AID IN CLIMBING. 2.ACCESS GATES SHALL BE A MINIMUM OF 60 INCHES ABOVE GRADE AND SHALL BE SELF CLOSING AND HAVE SELF LATCHING DEVICE. GATES MUST OPEN OUTWARD FROM THE POOL. GATES SHALL MEET THE SAME PROVISIONS AS LISTED AS BARRIERS. 3.OUTSIDE SURFACES SHALL BE FREE OF ANYTHING THAT CAN MAKE THE BARRIER CLIMBABLE 4.IF USING THE WALL OF THE HOUSE AS AN ENCLOSURE, EXIT ALARMS MUST BE PLACE ON ALL DOORS THAT PROVIDE DIRECT ACCESS TO THE POOL. SUCTION OUTLETS: 1.POOLS AND SPAS MUST HAVE AT LEAST TWO CIRCULATION OUTLETS, WHICH ARE HYDRAULICALLY BALANCED AND SEPARATED BY THREE FEET OR 2.UTILIZATION OF SKIMMERS, PERIMETER OVERFLOW SYSTEMS, OR OTHER PRE-APPROVED DEVICES IN LIEU OF TRADITIONAL SUCTION DEVICES. 3.THE USE OF OTHER OUTLET DEVICES WHICH MAY MEET ANSI/APSP-7 STANDARDS BUT DO NOT HAVE A MINIMUM OF THREE FEET BETWEEN OUTLETS IS PROHIBITED. SP-1.0 CO V E R S H E E T N.T.S. SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-08-2021 dateno.revisions 03/18/2021J.ANAYA BPOL2021-0086 SPRINGERS / POOL,SPA AND [1]GAS OUTLET AT REAR YARD. DETACHED SPA AT GAMEROOM COURT YARD. ENTRY WATER FEATURE AND [3] FIRE FEATURES. [SPIRE ENGINEERING] TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTIONTT FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. D SP-4.0 RESIDENCE POOL SPA N 67°11'34" E 274.26' LOT 29 EXIST. RES. NOT LOCATED LOT 31 EXIST. RES. N 69°34'18" E 272.54' 1 3 7 . 6 1 ' R O S S A V E N 3 4 ° 0 7 ' 4 4 " W 3 9 . 9 7 ' FIRE PIT FIRE PIT FIRE PIT FIRE PIT BBQ EQUIP. 40'-0" SET B A C K 1 5 ' - 0 " S E T B A C K 30'-0" SETBACK P R O P E R T Y L I N E PROPERTY LINE SPA A SP-5.0 A SP-3.0 10'-0" 20 ' - 1 1 1 2" 32 ' - 0 " 32 ' - 0 " 16 ' - 8 " 36 ' - 0 " A SP-4.0 EQUIP. 15 ' - 0 " S E T B A C K BAJA SHELF B SP-5.0 WATER WALL FEATURE WATER SPEC'S POOL SIZE DEPTH PERIMETER AREA VOLUME TROUGH SIZE DEPTH PERIMETER AREA VOLUME 27'-0"x100'-0" 3'-6" TO 6'-0" 273 I.F. 2,280 S.F. 81,000 GAL. VARIESx104' 30" 224 I.F. 328 S.F. 5,500 GAL. SPA @ POOL SIZE DEPTH PERIMETER AREA VOLUME 7'-6"x20'-0" 3'-6" 55 I.F. 150 S.F. 2,500 GAL. INSIDE SPA SIZE DEPTH PERIMETER AREA VOLUME 8'-5"x8'-6" 3'-6" 34 I.F. 72 S.F. 450 GAL. ENTRY WATER FEATURE SIZE DEPTH PERIMETER AREA VOLUME 3'x25'-9" 18" TROUGH - - 700 GAL. SITE PLAN SCALE: 3/32"=1'-0" PO O L S I T E P L A N 1/16"=1'-0" SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-10-2021 dateno.revisions SP-2.0 03/18/2021J.ANAYA A1 SP-3.1 27 ' - 0 " A1 SP-3.1 A2 SP-3.1 SPA WD: -54" A2 SP-3.1 WD: -9" WD: -18" WD: -27" WD: -36" WD: -45" WD: -54" WD: -21" WD: -9" WD: -49" A3 SP-3.1 A3 SP-3.1 7' - 6 " 15 ' - 0 " 1' - 3 " 32'-0"1'-0"6'-0"1'-0"20'-0"1'-0"6'-0"1'-0"32'-0" 100'-0" 7' - 6 " 1' - 0 " +/-104'-3" 1' - 0 " 13 ' - 0 " 1' - 0 " 1' - 0 " 25 ' - 0 " 1' - 0 " 1' - 0 " 7' - 6 " POOL WD: -54" 1 S-2 1 S-2 1 S-2 4 S-2 4 S-2 1' - 0 " 18 ' - 7 " 1' - 0 " 5' - 5 " 1' - 0 " 1' - 0 " 13 ' - 0 " 1' - 0 " 5' - 7 " WD: -54"WD: -54" WD: -72 WD: -48" 2' - 0 " 1'-3 " 1' - 6 " 2'-9 " BAJA SHELF 1'-0"7'-0"WD: -9" WD: -18" WD: -27" WD: -36" WD: -45" WD: -54" 2 S-2 2 S-2 2 S-2 4 S-2 3 S-2 SIM. A SCALE: 1/4" = 1'-0" POOL PLAN SP-3.0 1/2"-1'-0" EN L A R G E D P O O L P L A N SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-08-2021 dateno.revisions 03/18/2021J.ANAYA POOL 2 S-2 WATER LINE F. F. 4 S-2 F. F. 6' - 0 " 4' - 6 " 4' - 1 " BAJA SHELF SIM. INFINITY WALL POOL WATER LINE 4 S-2 F. F. 1 S-2 INFINITY WALL POOL WATER LINE F. F. 1 S-2 SPA 3 S-2 WATERFALL BAR TOP 1" COMPRESSIBLE FOAM FOUNDATION PER STRUCTURAL ENGINEER 13" CLEAR SAND 1" COMPRESSIBLE FOAM FS COURT -14" 1'-2"4'-7"1'-5"3"1'-0" FS @BAR +44" 2' - 3 " 6" 4" 1' - 8 " FS +15" 4' - 1 " FF @POOL TABLE +0" WATER LINE 10 " 1' - 2 " 2' - 0 " 1' - 3 " 10 " NOTE: SEE SECTION 5/S-3 FOR REINF. 2" 3' - 8 " A1 SCALE: 1/4"=1'-0" POOL SECTION A2 SCALE: 1/4"=1'-0" POOL SECTION PO O L S E C T I O N S SP-3.1 AS NOTED SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-08-2021 dateno.revisions A3 SCALE: 1/4"=1'-0" POOL SECTION A4 SCALE: 1/4"=1'-0" GAME ROOM SPA SECTION 03/18/2021J.ANAYA WD: -8 A SCALE: 1/4" = 1'-0" PLUMBING PLAN SP-3.2 1/2"-1'-0" EN L A R G E D P O O L PL U M B I N G P L A N SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 02-15-2021 dateno.revisions 03/18/2021J.ANAYA WD: -30" 6 S-3 6 S-3 6" +/-25'-9" FIELD VERIFY 6' - 4 " 1' - 6 " 10 " 6" 3' - 0 " WD: -32" 1/4"x3"x9" STEEL BRACKET EVERY 12" TYP. LINE OF "VALANCE" TO HIDE RAIN CURTAIN 2'-6"2'-6" 10 " 3'-0" MIN. SEPARATION 3" PVC TO P- 1" ELECTRICAL CONDUIT TO J-01 5'-0"5'-0"5'-0"5'-0" 3" PVC FROM F- 20' LONG CUSTOM CASCADE R RR AF 3'-0" MIN. SEPARATION 3" PVC TO P- 1-1/2" PVC TO P-1-1/2" PVC TO P-1-1/2" PVC TO P- SPA WD: -24" 8' - 5 " 8'-6" WD: -44" F.S. COURT: -14" A4 SP-3.1 A4 SP-3.1 1'-0"1'-6"1'-0"3'-6" BENCH RECESS IN CONCRETE FUNDATION RECESS IN CONCRETE FUNDATION RECESS IN CONCRETE FUNDATION WD: -34" F.S.: +0" F.S.: +15" 1'-6" AF SK 3' - 0 " M I N . 2-1/2" PVC TO P- 2-1/2" PVC TO P- 3'-0" MIN. 2" PVC FROM H- AF 2" PVC TO P- SK 1" ELECTRICAL CONDUIT TO J-01 1" ELECTRICAL CONDUIT TO J-01 MID LOW DBLDBL LOW MID DBL 2-1/2" PVC FROM P- AUTO FILL EQUALIZER 2-1/2" PVC FROM P- R R A SCALE: 1/2" = 1'-0" WATER FEATURE PLAN SP-4.0 1/2"-1'-0" IN T E R I O R S P A A N D W A T E R FE A T U R E P L A N A N D PL U M B I N G P L A N SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-08-2021 dateno.revisions B SCALE: 1/2" = 1'-0" WATER FEATURE PLUMBING PLAN POOL LEGEND FLOOR DRAIN MAIN DRAIN SUCTION, 3FT MIN. SEPARATION UMBRELLA SLEVE FLUSH RETURN SKIMMER SMALL FRONT LOADING SKIMMER AUTO FILL DECK JET VACUUM PORT GAS METER SPA JET ELECTRICAL M "CMP" BRILLIANT WONDERS LED POOL BUBBLER CRYSTAL WATER JETS 20" DIA. AQUASTAR FLOOR DRAIN LED NICHELESS LIGHT UP NICHELESS LIGHT ELECTRICAL CONDUIT RETURN LINE SUCTION LINE PE GAS LINE MD U SJ R SK AF D VP G S ABBREVIATIONS W.S. WATER SURFACE W.D.WATER DEPTH F.F.FINISHED FLOOR F.S.FINISHED SURFACE F.G.FINISH GRADE ELEV.GRADE ELEVATION D SCALE: 1/2" = 1'-0" GAME ROOM SPA PLAN E SCALE: 1/2" = 1'-0" GAME ROOM SPA PLUMBING PLAN 03/18/2021J.ANAYA EQUIPMENT SCHEDULE NO.TYPE LOCATION MFR MODEL NO. LIGHT SCHEDULE TYPE LOCATION MFR MODEL NO.QTY P-01 FILTER PUMP POOL/SPA JANDY F-01 FILTER H-01 HEATER JXi400 CV/CL 460 VSPHP270DV2A LED POOL JANDY JLU4C24W 28 SPAP-02 FILTER PUMP P-03 FILTER PUMP P-04 FILTER PUMP P-05 INF. PUMP P-06 P-07 P-08 F-02 FILTER F-03 FILTER F-04 FILTER H-02 HEATER H-03 HEATER H-04 HEATER POOL POOL SPA WATER FEATURE SPA SPA WATER FEATURE POOL/SPA POOL SPA POOL/SPA POOL SPA POOL F-05 FILTER GAME ROOM SPA POOL P-09 P-12 P-13 FILTER PUMP P-14 FILTER PUMP POOL POOL SPA LED JANDY 4 GAME SPALED JANDY 2 WATER FEATURELED JANDY 5 INF. PUMP JET PUMP JET PUMP JET PUMP H-05 HEATER GAME ROOM SPA F-06 FILTER WATER FEATURE JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY JANDY P-10 P-11 FILTER PUMP JET PUMP JET PUMP GAME ROOM SPA GAME ROOM SPA GAME ROOM SPA JXi400 JXi400 JXi400 JXi400 CV/CL 460 CV/CL 460 CV/CL 460 CV/CL 460 CV/CL 460 PHPF2.0 PHPF2.0 PHPF2.0 PHPF2.0 PHPF2.0 VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A VSPHP270DV2A JLU4C24W JLU4C24W JLU4C24W P 09 6"1'-3"6" P 08 F 04 H 04 1' - 6 " 3'-0" P 10 H 06 F 05 1'-3"6"1'-3" 24'-9" 9" 3' - 0 " JANDY PANEL SUB PANEL 4'-0"3'-0" 1' - 3 " 6" 1' - 3 " 6" 2' - 0 " 1' - 6 " 2' - 0 " 6" 6" 2' - 0 " 6" 1' - 3 " 6" 1' - 3 " 6" 1' - 3 " 6" P 11 P 14 F 06 P 13 P 12 F 03 F 02 F 01 P 07 P 06 P 05 P 04 P 03 P 02 P 01 H 03 H 02 H 01 3' - 0 " 3' - 0 " 6"2'-0"1'-0"1'-3"6"2'-0"1'-0"1'-3"6"2'-0"1'-0"1'-3"6"2'-0"1'-0"1'-3"6" JANDY PANEL SP-5.0 1/2"-1'-0" EQ U I P M E N T L A Y O U T AN D S C H E D U L E SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-10-2021 dateno.revisions B SCALE: 1/2" = 1'-0" GAME ROOM SPA & WATER FEATURE EQUIP. LAYOUTA SCALE: 1/2" = 1'-0" POOL/SPA EQUIP. LAYOUT 03/18/2021J.ANAYA SOILS AND FOUNDATIONS 1. THE DESIGN OF THE FOUNDATION SYSTEM IS BASED UPON THE CRITERIA AND RECOMMENDATIONS CONTAINED IN THE FOLLOWING GEOTECHNICAL INVESTIGATION REPORT: A. "MADISON CLUB, TENTATIVE TRACT MAP 33076, NEC AVENUE 54 AND MADISON STREET, LA QUINTA, CALIFORNIA, GEOTECHNICAL INVESTIGATION" BY SLADDEN ENGINEERING (PROJECT No. 544-4810), DATED 01.28.05. B. "PROPOSED CUSTOM RESIDENCE, 53335 ROSS AVENUE, THE MADISON CLUB LOT 30A, LA QUINTA, CALIFORNIA" BY SLADDEN ENGINEERING (PROJECT No. 544-20168, DATED 05.28.20. 2. LOCATE AND PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER CONSTRUCTION. 3. REMOVE ABANDONED FOOTINGS, UTILITIES, ETC. WHICH INTERFERE WITH NEW CONSTRUCTION, UNLESS OTHERWISE INDICATED. 4. NOTIFY THE SEOR IF ANY BURIED STRUCTURES NOT INDICATED, SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. ARE FOUND. 5. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION. 6. REMOVE LOOSE SOIL AND STANDING WATER FROM FOUNDATION EXCAVATIONS PRIOR TO PLACING CONCRETE. 7. BOTTOM OF FOOTINGS SHALL BE LEVEL. FOOTING ELEVATION CHANGES SHALL BE MADE USING FOOTING STEPS. 8. EXCAVATIONS FOR FOUNDATIONS MUST BE ACCEPTED BY THE GEOTECHNICAL ENGINEER OF RECORD (GEOR) PRIOR TO PLACING REINFORCING AND CONCRETE. NOTIFY THE GEOR WHEN EXCAVATIONS ARE READY FOR INSPECTION. 9. PLACE BACKFILL BEHIND RETAINING WALLS AFTER CONCRETE HAS ATTAINED FULL DESIGN STRENGTH. 10. MECHANICALLY COMPACT EXCAVATION BACKFILLS IN LAYERS. PROVIDE 90% MINIMUM COMPACTION IN ACCORDANCE WITH THE ASTM D1557 TEST METHOD AND THE GEOTECHNICAL REPORT. 11. SCARIFY AND RECOMPACT TOP 6 INCHES OF SOIL BENEATH FILL PER ITEM ABOVE. 12. PROVIDE POSITIVE SLOPES, BOTH DURING AND AFTER CONSTRUCTION, TO DIRECT SURFACE AND ROOF RUNOFF A MINIMUM OF 10'-0” FROM BUILDING FOUNDATIONS. REINFORCING STEEL 1. REINFORCING SHALL BE FABRICATED ACCORDING TO THE “MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION” AND SHALL CONFORM TO ASTM A615, GRADE 60. 2. PROVIDE REINFORCING SHOWN OR NOTED CONTINUOUS IN LENGTHS AS LONG AS PRACTICABLE. 3. TERMINATE REINFORCING STEEL IN STANDARD HOOKS UNLESS OTHERWISE SHOWN. 4. ALL REINFORCING STEEL INTERRUPTED BY STRUCTURAL STEEL SHALL TERMINATE WITHIN 1" OF STEEL SURFACE WITH A 90° STANDARD HOOK UNLESS OTHERWISE NOTED. 5. PROVIDE REINFORCING BAR DOWELS IN FOOTINGS, PILE CAPS AND OTHER SUPPORTING MEMBERS OF THE SAME SIZE AND SPACING AS VERTICAL REINFORCING UNLESS OTHERWISE NOTED. LAP SPLICE AS INDICATED ON TYPICAL DETAILS. 6. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE BEFORE CONCRETE IS PLACED. 7. ACCURATELY POSITION, SUPPORT AND SECURE REINFORCEMENT FROM DISPLACING DUE TO FORMWORK, CONSTRUCTION, OR CONCRETE PLACEMENT OPERATIONS. LOCATE AND SUPPORT REINFORCING BY METAL CHAIRS, RUNNERS, BOLSTERS, SPACERS AND HANGERS AT A MAXIMUM SPACING OF 3'-0”. 8. FIELD BENDING OF REINFORCING STEEL EMBEDDED IN CONCRETE SHALL NOT BE ALLOWED UNLESS APPROVED BY THE SEOR. 9. MILL CERTIFICATIONS SHALL BE SUBMITTED FOR REVIEW. GENERAL 1. MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2019 EDITION OF THE CALIFORNIA BUILDING CODE, TITLE 24, THE ORDINANCES OF THE LOCAL BUILDING OFFICIAL, AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 2. REFERENCE TO CODES, RULES REGULATIONS, STANDARDS, MANUFACTURER'S INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. 3. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, USE SIMILAR DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY THE STRUCTURAL ENGINEER OF RECORD (SEOR). 4. DETAILS ON SHEETS TITLED “TYPICAL DETAILS” APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OF SIMILAR TO THOSE SPECIFICALLY REFERENCED. SUCH DETAILS ARE NOT NOTED AT EACH LOCATION THAT THEY OCCUR. 5. SEE POOL DRAWINGS (SP SHEETS) FOR ADDITIONAL INFORMATION. 6. VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. NOTIFY SEOR OF DISCREPANCIES. 7. DO NOT SCALE THE DRAWINGS. 8. TOLERANCES SHALL BE ACCORDING TO THE BUILDING CODE. 9. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES. NOTIFY THE SEOR OF ANY DISCREPANCIES AND RESOLVE BEFORE PROCEEDING WITH THE WORK. 10. PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING AND SHORING FOR LOADS DURING CONSTRUCTION. RETAIN A REGISTERED CIVIL ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING, SHORING, ETC. VISITS TO THE SITE BY THE OWNER'S REPRESENTATIVE WILL NOT INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS. 11. THE CONTRACTOR SHALL SUPERVISE, DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. THE SUPPORTING SERVICES BY THE SEOR, WHETHER PERFORMED PRIOR TO, DURING, OR AFTER CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DRAWINGS; BUT THEY DO NOT GUARANTEE THE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. 12. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING A SAFE PLACE TO WORK AND MEETING THE REQUIREMENTS OF ALL APPLICABLE JURISDICTIONS. EXECUTE WORK TO ENSURE THE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY FALLING DEBRIS AND OTHER HAZARDS RELATED WITH THIS WORK. STATEMENT OF SPECIAL INSPECTIONS (& STRUCTURAL TESTS) 1. STRUCTURAL TESTS AND INSPECTIONS SHALL BE ACCORDING TO 2019 CALIFORNIA BUILDING CODE. 2. THE SPECIAL INSPECTIONS IDENTIFIED ARE IN ADDITION TO THOSE REQUIRED BY SECTION 110 OF THE CODE, AS AMENDED. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY THE GOVERNING JURISDICTION. 3. AN INDEPENDENT TESTING AGENCY AND SPECIAL INSPECTORS WILL BE RETAINED BY THE OWNER (NOT THE CONTRACTOR OR ANY OTHER PERSON RESPONSIBLE FOR THE WORK) TO PERFORM TESTS AND SPECIAL INSPECTIONS. THE CONTRACTOR SHALL PROVIDE ACCESS AND FURNISH SAMPLES TO THE AGENCY AS REQUIRED. 4. IF INITIAL TESTS OR INSPECTIONS MADE BY THE OWNER'S TESTING AGENCY REVEAL THAT ANY PORTION OF THE WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, ADDITIONAL TESTS, INSPECTIONS AND NECESSARY REPAIRS WILL BE MADE AT THE CONTRACTOR'S EXPENSE. 5. A CERTIFICATE OF SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION MUST BE COMPLETED AND SUBMITTED TO THE GOVERNING JURISDICTION AND SEOR. 6. PERIODIC OR CONTINUOUS PRESENCE AND INSPECTION BY THE PROJECT OR SPECIAL INSPECTOR ARE REQUIRED FOR THE FOLLOWING TYPES OF WORK WHERE OCCURS: REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION (CBC TABLE 1705.3) TYPE INSPECTION FREQUENCY REFERENCED STANDARD IBC REFERENCE 1.INSPECT REINFORCEMENT AND VERIFY PLACEMENT.PERIODIC ACI 318 CH 20, 25.2, 25.3, 26.6.1-26.6.3 1908.4 3.INSPECT ANCHORS CAST IN CONCRETE PERIODIC ACI 318: 17.8.2 --- 5. VERIFY USE OF REQUIRED DESIGN MIX. PERIODIC ACI 318: CH. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3 6. PRIOR TO GUNITE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE GUNITE. CONTINUOUS ASTM C172 ASTM C31 ACI 318: 26.5, 26.12 1908.10 7.INSPECT GUNITE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.CONTINUOUS ACI 318: 26.5 1908.6, 1908.7, 1908.8 8.VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.PERIODIC ACI 318: 26.5.3-26.5.5 1908.9 12.INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.PERIODIC ACI 318: 26.11.1.2(b) --- STRUCTURAL OBSERVATION -NOT REQUIRED ABBREVIATIONS AB ANCHOR BOLT ABV ABOVE ADDL ADDITIONAL AFF ABOVE FINISH FLOOR ALT ALTERNATE BLDG BUILDING BLKG BLOCKING BM BEAM BN BOUNDARY NAIL BOF BOTTOM OF FOOTING BOT BOTTOM BRG BEARING BSMT BASEMENT BTWN BETWEEN C CHANNEL, CAMBER CANT CANTILEVER(ED) CIP CAST-IN-PLACE CJ CONTROL JOINT, CLG JOIST CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CTSK COUNTERSINK CTR CENTER(ED) DBL DOUBLE DEMO DEMOLISH, DEMOLITION DET DETAIL DF DOUGLAS FIR DIA, Φ DIAMETER DIAG DIAGONAL DIAPH DIAPHRAGM DIM DIMENSION DIST DISTANCE DN DOWN DO DITTO (REPEAT) DWG(S) DRAWING(S) (E), EXIST EXISTING EA EACH E.A. EXPANSION ANCHOR EF EACH FACE EJ EXPANSION JOINT EA EACH ELEV ELEVATOR, ELEVATION EMB(ED)EMBEDMENT EN EDGE NAIL EQ EQUAL ES EACH SIDE,EDGE SCREW EW EACH WAY EXT EXTERIOR FDN FOUNDATION FF FINISHED FLOOR FJ FLOOR JOIST FLR FLOOR FN FIELD NAIL FO FACE OF FOC FACE OF CONCRETE FOM FACE OF MASONRY FOS FACE OF STUD FOW FACE OF WALL FS FAR SIDE, FIELD SCREW FTG FOOTING GA, ga GAGE, GAUGE GALV GALVANIZED GLB GLU-LAM BEAM GYP BD GYPSUM BOARD HD HOLDOWN HDR HEADER HDG HOT DIPPED GALVANIZED HGR HANGER HORIZ, (H) HORIZONTAL HP HIGH POINT HSB HIGH STRENGTH BOLT HSS HOLLOW STRUCTURAL STEEL HT HEIGHT K KIPS, 1000# KP KING POST L ANGLE LB(S), #POUND Ld DEVELOPMENT LENGTH Ldh HOOKED DEVELOPMENT LENGTH LLBB LONG LEG BACK-TO-BACK LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LONG LONGITUDINAL LP LOW POINT Ls LAP SPLICE LENGTH LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER LWC LIGHTWEIGHT CONCRETE MB MACHINE BOLT MEP MECH, ELEC & PLUMBING MFR MANUFACTURER MTL METAL (N) NEW NF NEAR FACE NIC NOT IN CONTACT NO, # NUMBER NS NEAR SIDE NSG NON SHRINK GROUT NTS NOT TO SCALE NWC NORMALWEIGHT CONCRETE oc ON CENTER OH OPPOSITE HAND OPNG OPENING OWSJ OPEN WEB STEEL JOIST PAF POWER ACTUATED FASTENER PERP PERPENDICULAR PJP PARTIAL JOINT PENETRATION PL PLATE PP PER PLAN PSF POUNDS/ SQUARE FOOT PSI POUNDS/ SQUARE INCH PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED R, RAD RADIUS REINF REINFORCEMENT REQD REQUIRED RJ ROOF JOIST RO ROUGH OPENING RR ROOF RAFTER S.A.D. SEE ARCH DOCUMENTS SC SLIP-CRITICAL SCHED SCHEDULE SECT SECTION S.E.D. SEE ELEC DOCUMENTS SEOR STRUCTURAL ENGINEER OF RECORD SHT SHEET SHTG SHEATHING SIM SIMILAR SL SLOPE S.M.D. SEE MECH DOCUMENTS SMS SHEET METAL SCREW S.O.G. SLAB ON GRADE SPEC SPECIFICATION(S) SQ SQUARE SS STAINLESS STEEL ST SNUG-TIGHTENED STAG STAGGER(ED) STD STANDARD STL STEEL STRUC STRUCTURAL SUSP SUSPENDED SW SHEAR WALL T&B TOP AND BOTTOM T&G TONGUE AND GROOVE THK THICK(NESS) THD THREADED TN TOE NAIL TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FOOTING TOFR TOP OF FRAMING TOS TOP OF STEEL TOW TOP OF WALL TRANS TRANSVERSE TS TOP OF SHEATHING TSG TAPERED STEEL GIRDER TYP TYPICAL UON UNLESS OTHERWISE NOTED VERT,(V) VERTICAL VIF VERIFY IN FIELD W WIDE FLANGE w/ WITH w/o WITHOUT WHS WELDED HEADED STUD WP WORK POINT WT WEIGHT WTS WELDED THREADED STUD WWF WELDED WIRE MESH XS EXTRA STRONG XXS DOUBLE EXTRA STRONG ATR ALL-THREAD ROD S.C.D. SEE CIVIL DOCUMENTS S.P.D. SEE PLUMB DOCUMENTS R/R REMOVE & REPLACE WS WOOD SCREW A.A. ADHESIVE ANCHOR A.D. ADHESIVE DOWEL PCF POUNDS/ CUBIC FEET RS ROUGH SAWN LOC LOCATION JT JOINT BLW BELOW FG FINISHED GRADE TOT TOTAL LO LOW ADJ ADJACENT HI HIGH MDL MODEL DESIGN CRITERIA 1. THE OBJECTIVE OF THIS WORK IS TO DESIGN A POOL AND SPA FOR THE RESIDENTIAL PROPERTY. SCOPE ALSO INCLUDES A STAND-ALONE WATER FEATURE. 2. DESIGN LOAD CRITERIA: A. ALLOWABLE COEFFICIENT OF FRICTION: 0.48 B. ALLOWABLE SLIDING RESISTANCE: 130 PSF (50% OF WEIGHT MAXIMUM) C. ALLOWABLE PASSIVE PRESSURE: 300 PCF D. FRICTION AND PASSIVE PRESSURE MAY BE COMBINED IN CALCULATION OF TOTAL RESISTANCE TO SLIDING (WITH A 33% REDUCTION IN FRICTION RESISTANCE). E. A ONE-THIRD INCREASE IS APPLICABLE TO SOIL CAPACITIES FOR SHORT-TERM LOADING (WIND/SEISMIC). F. SOIL RETAINING STRUCTURES: 3. FOUNDATIONS (BASED ON GEOTECHNICAL REPORT): GRAVITY LOADS ACTUAL STRUCTURE & OPERATING EQUIPMENT WEIGHTSDEAD LOADS ULTIMATE WIND LOADS EXPOSURE CATEGORY C II (T.1604.5)RISK CATEGORY DESIGN WIND SPEED, VULT,VASD 110 MPH PER ATC TOOL, 85 PER EQN 16-33 IMPORTANCE FACTOR, IP 1.0 (RISK CATEGORY II, T.1604.5) ULTIMATE SEISMIC LOADS (COMPONENTS) MAPPED SPECTRAL ACCELERATIONS SS = 1.50g,S1 = 0.61g (PER GEOTECHNICAL REPORT) SITE CLASS D (PER GEOTECHNICAL REPORT) DESIGN SPECTRAL RESPONSE COEFFICIENTS SDS = 1.00g, SD1 = NULL SEISMIC DESIGN CATEGORY D FOOTING TYPE ALLOWABLE NET PRESSURE, D+L (PSF) MIN WxH* (IN) INCREASE WITH WIDTH, D+L (PSF/FT) INCREASE WITH DEPTH, D+L (PSF/FT) MAX ALLOWABLE NET PRESSURE, D+L (PSF) CONTINUOUS 1,500 12x12 300 600 3,000 ISOLATED PAD 2,000 24x12 300 600 3,000 LATERAL PRESSURE & SLIDING RESISTANCE LEVEL GRANULAR BACKFILL (PCF) 2:1 GRANULAR BACKFILL (PCF) ACTIVE PRESSURE (PER GEOTECHNICAL REPORT)35 AT-REST (RESTRAINED WALLS) PRESSURE (PER GEOTECHNICAL REPORT)55 *H= MIN EMBEDMENT BELOW LOWEST ADJACENT GRADE. FORMWORK 1. PROVIDE CURING WHERE FORMS ARE REMOVED IN LESS THAN 7 DAYS. 2. REMOVE FORMS NO SOONER THAN 48 HOURS AFTER PLACING CONCRETE. GUNITE 1. WHERE NOT SPECIFIED, GUNITE MAY BE USED AS AN ALTERNATIVE TO CAST-IN-PLACE CONCRETE. A. GUNITE SHALL CONFORM TO THE REQUIREMENTS OF THE 2019 CBC SECTION 1913 AND CHAPTER 19 IN GENERAL FOR REINFORCED CONCRETE AND PROVISIONS OF ACI 1506. 2. GUNITE SHALL HAVE THE SAME COMPRESSIVE STRENGTH (f'c) AND ALL OTHER REQUIREMENTS AS CAST-IN-PLACE CONCRETE UNLESS OTHERWISE NOTED. 3. THE NOMINAL MAXIMUM SIZE OF COARSE AGGREGATES SHALL BE ¾" UNLESS OTHERWISE NOTED. A. WHEN #5 OR SMALLER BARS ARE USED, THERE SHALL BE A MINIMUM CLEARANCE BETWEEN PARALLEL REINFORCEMENT BARS OF 2½ INCHES. 4. LAP SPLICES IN REINFORCING BARS SHALL BE BY THE NON-CONTACT LAP SPLICE METHOD WITH AT LEAST 2 INCHES CLEARANCE BETWEEN BARS. 5. CONCRETE TO RECEIVE GUNITE SHALL HAVE THE ENTIRE SURFACE THOROUGHLY CLEANED AND ROUGHENED BY SAND BLASTING, AND JUST PRIOR TO RECEIVING GUNITE, SHALL BE THOROUGHLY CLEANED OF ALL DEBRIS, DIRT AND DUST. CONCRETE SHALL BE WETTED BEFORE GUNITE IS DEPOSITED, BUT NOT SO WET AS TO OVERCOME SUCTION. SAND FOR SAND BLASTING SHALL BE CLEAN, SHARP AND UNIFORM IN SIZE, WITH NO PARTICLES THAT WILL PASS A 50-MESH SCREEN. 6. CURING SHALL BE IN ACCORDANCE WITH SECTION 1913.9. CURING COMPOUND USED ON GUNITE SHALL BE APPROVED BY THE SEOR. 7. STRENGTH TESTS FOR GUNITE SHALL BE MADE IN ACCORDANCE WITH ASTM STANDARDS BY AN APPROVED AGENCY ON SPECIMENS THAT ARE REPRESENTATIVE OF THE WORK AND WHICH HAVE BEEN WATER SOAKED FOR AT LEAST 24 HOURS PRIOR TO TESTING. THE MAXIMUM-SIZE AGGREGATE SHALL BE 3/8 INCH AND SPECIMENS SHALL CONSIST OF NOT LESS THAN 2-INCH-DIAMETER CORES OR 2-INCH CUBES. 8. SAMPLING FOR GUNITE SPECIMENS SHALL BE TAKEN FROM THE IN-PLACE-WORK AND SHALL BE TAKEN AT LEAST ONCE EACH SHIFT, BUT NOT LESS THAN ONE FOR EACH 50 CUBIC YARDS OF GUNITE. CAST-IN-PLACE CONCRETE 1. CONCRETE IS MILDLY REINFORCED AND CAST-IN-PLACE. WHERE REINFORCING IS NOT SPECIFICALLY SHOWN OR WHERE DETAILS ARE NOT GIVEN, PROVIDE REINFORCING SIMILAR TO THAT SHOWN FOR SIMILAR CONDITIONS, SUBJECT TO REVIEW BY THE SEOR. 2. DIMENSIONS SHOWN FOR LOCATION OF REINFORCING ARE TO THE FACE OF BARS AND DENOTE CLEAR COVERAGE UNLESS OTHERWISE NOTED. 3. THE MINIMUM CONCRETE CLEAR COVER TO REINFORCING BARS IS AS FOLLOWS: a. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS. FORMED SURFACES EXPOSED TO WEATHER OR IN CONTACT WITH EARTH: #5 BARS AND SMALLER 1½ #6 BARS AND LARGER 2 USE f'c (PSI) (a) MAX SLUMP (IN) NOMINAL MAX AGGREGATE (IN) WATER CEMENTITIOUS RATIO (MAX) TYPICAL 3,000 4 1 0.50 LOCATIONS CLEAR COVER, INCHES CONCRETE PLACED AGAINST EARTH 3 SLABS ON GRADE (TOP CLEARANCE)1½ 4. CONCRETE TYPES 5. CONCRETE MIXES SHALL BE DESIGNED BY A QUALIFIED TESTING LABORATORY, BEARING A CALIFORNIA REGISTERED CIVIL ENGINEER'S STAMP, AND APPROVED BY THE SEOR PRIOR TO USE. 6. PORTLAND CEMENT SHALL BE TYPE II OR V CONFORMING TO ASTM C150 UNLESS OTHERWISE NOTED. 7. COARSE AGGREGATE SHALL CONFORM TO ASTM C-33. 8. ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF) HARD ROCK TYPE. 9. CONTINUOUSLY MOIST CURE CONCRETE FOR 7 DAYS MINIMUM. WATER FOG SPRAYS, PONDING, SATURATED ABSORPTIVE COVERS OR MOISTURE RETAINING COVERS MAY BE USED. IN LIEU OF MOIST CURING, CURING COMPOUNDS MAY BE SUBMITTED TO THE ARCHITECT FOR ACCEPTANCE. 10. PIPES AND CONDUIT ARE TO BE PLACED IN THE MIDDLE THIRD OF SLABS AND WALLS. MAXIMUM DIAMETER SHALL BE ONE-THIRD OF SLAB OR WALL THICKNESS AND MINIMUM SPACING SHALL BE 3 DIAMETERS FROM CENTER TO CENTER. 11. ROUGHEN CONCRETE SURFACES OF CONSTRUCTION JOINTS TO ¼” AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER AND LOOSE PARTICLES. LOCATE CONSTRUCTION JOINTS AS SHOWN ON THE DRAWINGS. SUBMIT ALTERNATE JOINT LOCATIONS OR JOINTS NOT SHOWN TO THE SEOR FOR REVIEW AND APPROVAL PRIOR TO PROCEEDING WITH THE WORK. 12. AT LOCATIONS WHERE CONCRETE IS CAST AGAINST EXISTING CONCRETE, ROUGHEN CONTACT SURFACES TO ¼” AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER AND LOOSE PARTICLES. 13. CONSOLIDATE CONCRETE PLACED IN FORMS BY MECHANICAL VIBRATING EQUIPMENT SUPPLEMENTED BY HAND- SPADING, RODDING OR TAMPING. USE EQUIPMENT & PROCEDURES FOR CONSOLIDATION OF CONCRETE IN ACCORDANCE WITH THE RECOMMENDED PRACTICES OF ACI 309 TO SUIT THE TYPE OF CONCRETE & PROJECT CONDITIONS. 14. NO WOOD SPREADERS ALLOWED. NO WOOD STAKES ALLOWED IN AREAS TO BE CONCRETED. NOTES: 1. ALL DETAILING OF REINF SHALL COMPLY WITH THIS SCHEDULE UNLESS SPECIFICALLY DETAILED OTHERWISE. 2. REINF DEVELOPMENT LENGTH AND SPLICE TABLE IS BASED ON UNCOATED GRADE 60 STEEL PER ACI 318 CHAPTER 25 AND SECTION 18.8.5. 3. db = BAR DIAMETER. 4. NP = NOT PERMITTED. 5. TOP REINF IS HORIZONTAL REINF THAT HAS MORE THAN 12" OF CONCRETE PLACED BELOW IT. 6. LAP LENGTHS SHOWN MEET REQUIREMENTS FOR CLASS "B" SPLICE. 7. CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED SHALL NOT BE LESS THAN THE LARGER OF 2 BAR DIAMETERS OR 2". CLEAR COVER SHALL NOT BE LESS THAN THE LARGER OF THE BAR DIAMETER SIZE OR PER GENERAL NOTES. 8. A STANDARD HOOK SHALL BE PROVIDED WHERE THE DEVELOPMENT LENGTH IS NOT POSSIBLE DUE TO SPACE RESTRICTIONS (REFER TO HOOKED BAR SCHEDULE). 9. SMALLER BAR LAP LENGTH MAY BE USED WHEN SPLICING BARS OF DIFFERING DIAMETERS. 10. AT CONC WALLS, SPLICES IN HORIZONTAL REINF SHALL BE STAGGERED. 11. Ld = DEVELOPMENT LENGTH (DEV), Lst = LAP SPLICE (LAP). 2" MIN SPLICE BAR MAIN BAR f'c (PSI) HOOKED BAR DEVELOPMENT LENGTH, Ldh (INCHES) REINFORCEMENT DEVELOPMENT & LAP LENGTHS (INCHES) BASE MATERIAL NWC f'c (PSI)CONDITION REINFORCEMENT SIZE 3,000 STD DEV TOP DEV STD LAP TOP LAP #3 #4 #5 #6 17 22 28 33 23 29 37 43 23 29 37 43 29 38 48 56 #3 9 #4 11 #5 14 #6 17 REINFORCEMENT SIZE 3,000 Ld Lst Ldh 2db NOTE: d = BAR DIAMETER BAR OFFSET 1 6 MIN BAR END HOOKS & BENDS D D D 2½" MIN 4d OR 12 d D = 6d FOR #3 TO #8 D = 8d FOR #9 TO #11 D = 10d FOR #14 & #18 END HOOKS, ALL GRADES BAR SIZE D J #3 2¼" 3" 4" 5" 6"4½" 3¾" 3"#4 #5 #6 d NOTE: d = BAR DIAMETER D D 3" MIN 6d OR STIRRUP / TIE HOOKS & BENDS 3" MIN 6d D = 1½" FOR #3 D = 2" FOR #4 D = 2½" FOR #5 J 2'-6" TYP RECESS WALL PP 2- #5 VERT TYP SECTION AT WALL RECESS VERT REINF PP HORIZ REINF PP TYP ADD HORIZ REINF TO MATCH SIZE & SPACING OF HORIZ WALL REINF END OF WALL DOUBLE REINF PP LAP HORIZ WALL REINF PP 2- #5 MIN 2- #5 MIN END OF WALL SINGLE REINF PP WALL REINF PP STD HOOK ALT BEND PP WALL REINF PP TYP PP HORIZ LAP WALL INTERSECTION DOUBLE REINF 2- #5 CONT PP PP HORIZ LAP WALL REINF PP TYP ALT BEND 2- #5 VERT WALL INTERSECTION SINGLE REINF PP PP WALL REINF PP TYP HO R I Z L A P STD HOOK STD HOOK CORNER DOUBLE REINF CORNER SINGLE REINF PP PP HO R I Z L A P WALL REINF PP TYP 2- #5 VERT SCALE: NONE GENERAL NOTES 7 SCALE: NONE TYPICAL DEVELOPMENT & LAP LENGTHS 2 SCALE: NONE TYPICAL REINFORCEMENT BEND DETAILS 3 SCALE: NONE TYPICAL CONCRETE WALL DETAILS 1 w w w . s p i r e s t r u c t u r e s . c o m 26 4 6 1 R a n c h o P a r k w a y So u t h L a k e F o r e s t , C A 9 2 6 3 0 te l : 94 9 . 9 1 6 . 3 4 4 0 Copyright Spire Structural Engineering Inc. 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 SHEET: DATE: SCALE: DWN BY: dateno.revisions N.T.S. 02/09/21 4:45:27 PM EN G : J C W JO B # : 2 1 S P R 0 0 2 GE N E R A L N O T E S & T Y P I C A L DE T A I L S S1 MRP 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . LO T 3 0 05/18/18 03/18/2021J.ANAYA STONE / TILE ON EXPOSED FACE OF INFINITY WALL 1-1/2" STONE CAP STONE / TILE TO TROUGH FLOOR NATUR A L 6" WATER LINE STONE / TILE CAP 1'-0"PER PLAN GUNITE WALL 1" 1' - 6 " 2' - 9 " 6" 6" GRADE 6" 4" 10" MECHANICALLY COMPACT DISTURBED SOIL IN LAYERS TO A 90% MIN COMPACTION IN ACCORDANCE TO ASTM D1557 TEST METHOD 6" 3" CL R 3" CLR 2" 2" 2" DE V P E R 2/ S 1 T Y P 10 " 1 1 PEBBLE SHEEN FINISH T.B.D. #3 HORIZ @ 12"O.C EA FACE #3 DOWEL W/STD HOOK @12"O.C EA FACE (2)-#3 CONT 3" CLR ROUGHEN SURFACE #3 DOWEL W/STD HOOK @12"O.C DEPTH≤ 4'-6:#3 DOWEL W/STD HOOK @12"O.C DEPTH> 4'-6: ADD #3 DOWEL W/STD HOOK @6"O.C #3 @12"O.C EA WAY #3 @12"O.C EA WAY #3 HORIZ @12"O.C 6" FOR DEPTH≤4'-6" & 8" FOR DEPTH>4'-6" 2" 6" 1'-4" #3 HORIZ @12"O.C 2-#3 CONT. 3" CL R 1'-4" 1'-4" 2-#3 CONT. 6" F. F. GUNITE WALL STONE / TILE COPING MITER ALL CORNERS 4" CONCRETE S.O.G. APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH PEBBLE SHEEN FINISH T.B.D. MECHANICALLY COMPACT DISTURBED SOIL IN LAYERS TO A 90% MIN COMPACTION IN ACCORDANCE TO ASTM D1557 TEST METHOD #3@ 12" O.C. EA WAY WATERPROOF NON-POROUS SLIPSHEET WATER LINE 10" 6" 1" 1'-0" 8" 3" 3" 1'-3"1'-3"1'-3"1'-3" 2" 3" 9" 9" 9" 9" 9" 9" 6" TILE & SETTING BED 4' - 6 " 3'-6" 1' - 2 " 3" CL R LAP PER 2/S1 2"2" #3 CONT #3 DOWEL W/STD HOOK @12" O.C. #3@ 12" O.C. EA WAY 6" #3@ 12" O.C. EA WAY LAP PER 2/S1 #3 DOWEL W/STD HOOK @12" O.C. EA FACE SEE 1/S- FOR WALL DIMENSIONS & REINF 6" WATER LINE 1" 5" FINISH FLOOR COMPACTED SUBGRADE 6"8"6" TILE & SETTING BED 4" CONCRETE S.O.G. 6" WATER LINE TILE PEBBLE SHEEN FINISH T.B.D. GUNITE WALL 1" 5" APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH 10" 1'-0" STONE / TILE COPING MITER ALL CORNERS 4" WATERPROOF NON-POROUS SLIPSHEET 3" CLR 2" 2" CLR 2" CL R 3" 3" CLR #3 CONT. 8" #3 DOWEL W/STD HOOK @12" O.C. #3 DOWEL W/STD HOOK @12" O.C. #3 HORIZ @12" O.C. EA FACE SEE 1/S- FOR WALL DIMENSIONS & REINF 6" WATER LINE 1" 5" FINISH FLOOR COMPACTED SUBGRADE 6"8" 6" TILE & SETTING BED 4" CONCRETE S.O.G. 6" WATER LINE TILE PEBBLE SHEEN FINISH T.B.D. GUNITE WALL 1" 5" APPLY 2 COATS WATERPROOFING TO OVER FLOW TROUGH 10" 1'-0" STONE / TILE COPING MITER ALL CORNERS 4" WATERPROOF NON-POROUS SLIPSHEET 3" CLR 2" 2" CLR 2" CL R 3" 3" CLR #3 CONT. 8" #3 DOWEL W/STD HOOK @12" O.C. #3 DOWEL W/STD HOOK @12" O.C. #3 HORIZ @12" O.C. EA FACE 1 1 6" 6" PER PLAN PER PLAN 6" 6" 3" CLR 3" 3" #3 @12" O.C. EA WAY #3 HORIZ@12" O.C. #3 DOWEL W/STD HOOK@12" O.C. #3 HORIZ @12" O.C. 6" 1'-4" 2-#3 CONT. #3 @12" O.C. EA WAY 6" #3 DOWEL W/STD HOOK@12" O.C. DE T A I L S S-2 AS NOTED SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-10-2021 dateno.revisions 1 SCALE: 1"=1'-0" INFINITY WALL DETAIL 2 SCALE: 1"=1'-0" POOL EDGE DETAIL 4 SCALE: 1"=1'-0" POOL STEPS DETAIL 3 SCALE: 1"=1'-0" SPA EDGE DETAIL 3 2'-0" 2'-0" 03/18/2021J.ANAYA 6" GAP (BUILDING SEPARATION) USE NON-POROUS WATERPROOF SLIPSHEET STUD WALL AND FRAMING 6"10" 2' - 8 " 1'-0"3'-0" GUNITE 9' - 0 " 1'-6" 2' - 6 " 6"1'-6" 16'-0" MAX. HEIGHT LED LIGHT BY OTHERS PORCELAIN STONE PAVERS BY OTHERS PORCELAIN TILE PEBBLE FINISH F.F. FOOTING SIZE & REINF PER 1/S2 3" TY P CL R #4 @10" O.C LONG T&B ALT HKS 3" TYP. CLR ROUGHEN SURFACE TYP #4 @12" OC. CTR'D #4 @12" O.C. 112" 2" #4 @12" OC. EF #4 @12" O.C. EF #4 HORIZ. BARS @15" OC. EF #4 VERT. BARS @4" O.C. EF 2" 2' - 0 " 8'-6" MIN. 2" OREQ RAIN CURTAIN PORCELAIN STONE 1'-2" LINE OF EXTERIOR SOFFIT 1' - 0 " WATER LEVEL IN TROUGH WHEN WATER FEATURE IS OPERATING EXIST. FOUNDATION/ FOOTING OF HOUSE. BOTTOM OF FOOTING IS LEVEL WITH OR DEEPER THAN FOOTING AT WATER FEATURE #4 @6" O.C. TRANS T&B E/DTD HK EA END 1" COMPRESSIBLE FOAM 13" CLEAR SAND 1" COMPRESSIBLE FOAM FS @BAR +44" 1' - 1 " 6" 5" 11 2" 2" 4" 3" #3 @12" O.C EA WAY #3 DOWEL W/ STD HOOK @12" O.C. #3 HORIZ @12" O.C. #3 DOWEL W/ STD HOOK @12" O.C. #3 HORIZ @12" 2" #3 DOWEL W/ STD HOOK @12" O.C. 4' - 1 " WATER LINE FS COURT -14" FF @POOL TABLE +0" NOTE: FOR DIMENSIONS NOT SHOWN SEE A4/SP-3.1 #3 DOWEL W/ STD HOOK @12" O.C. 2" C L R 10" 2' - 5 " 10" 1 4" 334" 114" 314" 1' - 0 " 1/4"x3" WIDE STEEL BRACKET EVERY 12" FASTEN TO GUNITE 5" MASONRY BOLT (TOP&BOTTOM) 10" GUNITE WALL CUSTOM CASCADE RAIN FALL 90 20' LONG 114" 41 2"4"112" 3"3"1"2" 1-1/2" PVC PLUMBING LED STRIP LIGHTS CONTINUOUS BOTH SIDES HARDY BACKER PORCELAIN TILE 1/4"x STEEL PLATE ATTACHED SEPARATELY DE T A I L S S-3 AS NOTED SHEET: DATE: SCALE: DWN BY: LO T 3 0 53 - 3 3 5 R O S S A V E LA Q U I N T A , C A . 43 6 5 3 P a r k w a y E s p l a n a d e La Q u i n t a , C A 9 2 2 5 3 76 0 - 7 7 2 - 1 1 1 1 St o k e r p o o l s . c o m L i c # 8 2 0 1 3 2 ZB 03-10-2021 dateno.revisions 6 SCALE: 1" = 1'-0" WATER FEATURE DETAIL 5 SCALE: 1" = 1'-0" GAME ROOM SPA DETAIL CLR EA SIDE OF WALL 03/18/2021J.ANAYA