Cantera at Coral Mountain TR 31249 BCPR2021-0022 - Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
GENERAL INFORMATION
01 Project Name Plan 1 V122 (2179)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2019
06 Zip code 92210 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2179 19 Glazing Percentage (%)14.59%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CANTERA BY BEAZER HOMES / TRACT CONSTRUCTION
MASTER PLANS FOR DWELLINGS (SFD x 4) - PLANS 1, 2, 3, AND
4, FOR THE 2019 CODE CYCLE. 2019 CALIFORNIA BUILDING
CODES.
PLAN 1: 2,181SF
PLAN 2: 2,333SF
PLAN 3: 2,670SF
PLAN 4: 3,006SF
11/29/2021
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 54.1 23.9
Proposed Designs
North Facing 47.2 20.8 6.9 3.1
East Facing 50.3 23.9 3.8 0
South Facing 47.2 20.8 6.9 3.1
West Facing 47.9 21.5 6.2 2.4
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 5.86 kWdc
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.14 0.24 1.9 88.8
Space Cooling 94.13 74.65 19.48 20.7
IAQ Ventilation 11.34 11.34 0 0
Water Heating 9.67 8.77 0.9 9.3
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 117.28 95 22.28 19
Space Heating 2.14 0.61 1.53 71.5
Space Cooling 94.13 84.21 9.92 10.5
IAQ Ventilation 11.34 11.34 0 0
Water Heating 9.67 8.77 0.9 9.3
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 117.28 104.93 12.35 10.5
Space Heating 2.14 0.94 1.2 56.1
Space Cooling 94.13 73.8 20.33 21.6
IAQ Ventilation 11.34 11.34 0 0
Water Heating 9.67 8.77 0.9 9.3
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 117.28 94.85 22.43 19.1
Space Heating 2.14 0.58 1.56 72.9
Space Cooling 94.13 76.68 17.45 18.5
IAQ Ventilation 11.34 11.34 0 0
Water Heating 9.67 8.77 0.9 9.3
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 117.28 97.37 19.91 17
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
5 NA Premium Fixed (roof
mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Indoor air quality, balanced fan
•Non-standard roof reflectance
•Insulation below roof deck
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•-- None --
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1 V122 (2179)2179 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2179 9.04 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 305 69 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 350 45 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 545 198 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 499.6 30 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 239.9 17.8 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 149.1 0 n/a
Roof Home R-0+R-22 BD n/a n/a 2179 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 794 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 239.9 112 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 358.8 17.8 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 208.9 0 90
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Exterior Wall 2x6 Front 0 1 45 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior Wall 2x6 Left 90 1 45 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 198 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior Wall 2x6 Right 270 1 30 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 24 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 112 1
Door 4 Left Exterior Wall 17.8 0.7
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade Home 2179 187 None 80%No
Slab-on-Grade 2 __Garage__794 89 None 0%No
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-9.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-22 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 981.6
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System1
Heating and cooling system
other
Heating
Component
1
Cooling
Component
1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-96
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Required Required
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 1-1 123 0.853659 Balanced HRV 75 n/a
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 16:14:44
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-15 16:29:11
R16-18-20136
702-365-8080
Laura Jew
Beazer Homes
310 Commerce, Suite 150
Irvine, CA 92602
2021-07-15 21:08:51
N/A
714-285-2900 7021
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
GENERAL INFORMATION
01 Project Name Plan 2 V123 (2333)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2019
06 Zip code 92210 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2333 19 Glazing Percentage (%)16.25%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 52.9 23.6
Proposed Designs
North Facing 47 22.5 5.9 1.1
East Facing 47.8 23.3 5.1 0.3
South Facing 48.1 23.6 4.8 0
West Facing 45.9 21.4 7 2.2
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 6.13 kWdc
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.31 0.49 1.82 78.8
Space Cooling 95.52 79.11 16.41 17.2
IAQ Ventilation 10.59 10.59 0 0
Water Heating 9.09 8.24 0.85 9.4
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 117.51 98.43 19.08 16.2
Space Heating 2.31 0.57 1.74 75.3
Space Cooling 95.52 81.54 13.98 14.6
IAQ Ventilation 10.59 10.59 0 0
Water Heating 9.09 8.24 0.85 9.4
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 117.51 100.94 16.57 14.1
Space Heating 2.31 1.11 1.2 51.9
Space Cooling 95.52 81.77 13.75 14.4
IAQ Ventilation 10.59 10.59 0 0
Water Heating 9.09 8.24 0.85 9.4
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 117.51 101.71 15.8 13.4
Space Heating 2.31 0.89 1.42 61.5
Space Cooling 95.52 75.09 20.43 21.4
IAQ Ventilation 10.59 10.59 0 0
Water Heating 9.09 8.24 0.85 9.4
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 117.51 94.81 22.7 19.3
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
4.99 NA Premium Fixed (roof
mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Indoor air quality, balanced fan
•Non-standard roof reflectance
•Insulation below roof deck
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•-- None --
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2 V123 (2333)2333 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2333 9.04 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 0 Front 227.1 54 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 90 Left 510.2 147 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS +R4 180 Back 545 140 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 270 Right 666.1 62 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 317.9 17.8 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 158.2 0 n/a
Roof Home R-0+R-22 BD n/a n/a 2333 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 767 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 317.9 168 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 212.7 17.8 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 74.2 0 90
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Exterior Wall 2x6 Front 0 1 30 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior Wall 2x6 Left 90 1 147 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 140 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior Wall 2x6 Right 270 1 62 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 24 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 168 1
Door 4 Left Exterior Wall 17.8 0.7
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade Home 2333 214 None 80%No
Slab-on-Grade 2 __Garage__767 67 None 0%No
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS +R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-9.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-22 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1051.0
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System1
Heating and cooling system
other
Heating
Component
1
Cooling
Component
1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-96
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Required Required
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 1-1 123 0.853659 Balanced HRV 75 n/a
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:33:38
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-15 16:29:49
R16-18-20136
702-365-8080
Laura Jew
Beazer Homes
310 Commerce, Suite 150
Irvine, CA 92602
2021-07-15 21:08:51
N/A
714-285-2900 7021
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
GENERAL INFORMATION
01 Project Name Plan 3 S812 (2670)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2019
06 Zip code 92210 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.31
18 Total Cond. Floor Area (ft
2)2670 19 Glazing Percentage (%)13.37%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 52.3 23.5
Proposed Designs
North Facing 46.6 22 5.7 1.5
East Facing 47.6 23 4.7 0.5
South Facing 48 23.5 4.3 0
West Facing 45.4 20.8 6.9 2.7
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 6.22 kWdc
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.98 0.42 1.56 78.8
Space Cooling 85.23 70.8 14.43 16.9
IAQ Ventilation 9.26 9.26 0 0
Water Heating 7.99 7.24 0.75 9.4
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 104.46 87.72 16.74 16
Space Heating 1.98 0.46 1.52 76.8
Space Cooling 85.23 73.58 11.65 13.7
IAQ Ventilation 9.26 9.26 0 0
Water Heating 7.99 7.24 0.75 9.4
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 104.46 90.54 13.92 13.3
Space Heating 1.98 1.08 0.9 45.5
Space Cooling 85.23 74.3 10.93 12.8
IAQ Ventilation 9.26 9.26 0 0
Water Heating 7.99 7.24 0.75 9.4
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 104.46 91.88 12.58 12
Space Heating 1.98 0.87 1.11 56.1
Space Cooling 85.23 66.79 18.44 21.6
IAQ Ventilation 9.26 9.26 0 0
Water Heating 7.99 7.24 0.75 9.4
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 104.46 84.16 20.3 19.4
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
5.15 NA Premium Fixed (roof
mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Indoor air quality, balanced fan
•Non-standard roof reflectance
•Insulation below roof deck
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•-- None --
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3 S812 (2670)2670 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 2670 9.04 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 174.8 35 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 726.6 151 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 481.4 141 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 537.1 50 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 318 17.8 n/a
South Interior Surface
2x Home>>__Garage__Garage R-15 Wall n/a n/a 12.1 0 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 184.7 0 n/a
Roof Home R-0+R-22 BD n/a n/a 2670 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 561 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 306.6 145 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 90.8 0 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 275.5 73.8 90
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Exterior Wall 2x6 Front 0 1 15 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior Wall 2x6 Left 90 1 151 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 141 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior Wall 2x6 Right 270 1 50 0.28 NFRC 0.22 NFRC Bug Screen
Window 5 Window Front Exterior Wall Front 0 1 33 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 20 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 112 1
Door 4 Right Exterior Wall 73.8 0.7
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade Home 2670 211 None 80%No
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade 2 __Garage__561 74 None 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-9.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-22 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1202.8
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System1
Heating and cooling system
other
Heating
Component
1
Cooling
Component
1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-96
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 1-1 123 0.853659 Balanced HRV 75 n/a
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-15 15:23:12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-15 16:30:37
R16-18-20136
702-365-8080
Laura Jew
Beazer Homes
310 Commerce, Suite 150
Irvine, CA 92602
2021-07-15 21:08:51
N/A
714-285-2900 7021
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 1 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
GENERAL INFORMATION
01 Project Name Plan 4 V067 (3006)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2019
06 Zip code 92210 07 Software Version EnergyPro 8.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)3006 19 Glazing Percentage (%)15.50%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 2 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
ENERGY DESIGN RATING
Energy Design Ratings
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 51.1 23.1
Proposed Designs
North Facing 44.7 19.4 6.4 3.7
East Facing 48.4 23.1 2.7 0
South Facing 44.3 19 6.8 4.1
West Facing 45.7 20.3 5.4 2.8
RESULT:3:COMPLIES
¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment
² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
³ Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 6.62 kWdc
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 3 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.86 0.33 1.53 82.3
Space Cooling 84.53 68.53 16 18.9
IAQ Ventilation 8.22 8.22 0 0
Water Heating 7.09 6.43 0.66 9.3
Self Utilization Credit n/a 0 0 n/a
North Facing Compliance Total 101.7 83.51 18.19 17.9
Space Heating 1.86 0.86 1 53.8
Space Cooling 84.53 78.58 5.95 7
IAQ Ventilation 8.22 8.22 0 0
Water Heating 7.09 6.43 0.66 9.3
Self Utilization Credit n/a 0 0 n/a
East Facing Compliance Total 101.7 94.09 7.61 7.5
Space Heating 1.86 1.14 0.72 38.7
Space Cooling 84.53 66.48 18.05 21.4
IAQ Ventilation 8.22 8.22 0 0
Water Heating 7.09 6.43 0.66 9.3
Self Utilization Credit n/a 0 0 n/a
South Facing Compliance Total 101.7 82.27 19.43 19.1
Space Heating 1.86 0.72 1.14 61.3
Space Cooling 84.53 70.98 13.55 16
IAQ Ventilation 8.22 8.22 0 0
Water Heating 7.09 6.43 0.66 9.3
Self Utilization Credit n/a 0 0 n/a
West Facing Compliance Total 101.7 86.35 15.35 15.1
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 4 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)Tilt: (x in 12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
5.85 NA Premium Fixed (roof
mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Indoor air quality, balanced fan
•Non-standard roof reflectance
•Insulation below roof deck
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•-- None --
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 5 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 4 V067 (3006)3006 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Home Conditioned HVAC System1 3006 9.04 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 0 Front 312.5 90 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 90 Left 487.4 40 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS R4 180 Back 499.6 304 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 270 Right 663.1 52 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 187.7 17.8 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 354.2 0 n/a
Right Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 172.6 0 n/a
Roof Home R-0+R-22 BD n/a n/a 3006 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 610 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 187.7 112 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 186.2 16.7 90
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 6 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window Window Front Exterior Wall 2x6 Front 0 1 70 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior Wall 2x6 Left 90 1 40 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 304 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior Wall 2x6 Right 270 1 52 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 20 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 112 1
Door 4 Left Exterior Wall 16.7 0.7
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated
Slab-on-Grade Home 3006 216 None 80%No
Slab-on-Grade 2 __Garage__610 41 None 0%No
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 7 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043
Roofing: 10 PSF (RoofTile)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-9.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-22 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 8 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 1354.2
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
#
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff.
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.93-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 9 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System1
Heating and cooling system
other
Heating
Component
1
Cooling
Component
1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-96
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08
Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Required Required
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 10 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 11 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 1-1 125 0.84 Balanced HRV 75 n/a
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 12 of 12)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108
Schema Version: rev 20200101
Report Generated: 2021-07-13 09:14:29
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Cristela Lujan
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2021-07-15 16:31:28
R16-18-20136
702-365-8080
Laura Jew
Beazer Homes
310 Commerce, Suite 150
Irvine, CA 92602
2021-07-15 21:08:52
N/A
714-285-2900 7021
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.