Loading...
Cantera at Coral Mountain TR 31249 BCPR2021-0022 - Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 GENERAL INFORMATION 01 Project Name Plan 1 V122 (2179) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92210 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)2179 19 Glazing Percentage (%)14.59% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CANTERA BY BEAZER HOMES / TRACT CONSTRUCTION MASTER PLANS FOR DWELLINGS (SFD x 4) - PLANS 1, 2, 3, AND 4, FOR THE 2019 CODE CYCLE. 2019 CALIFORNIA BUILDING CODES. PLAN 1: 2,181SF PLAN 2: 2,333SF PLAN 3: 2,670SF PLAN 4: 3,006SF 11/29/2021 CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 ENERGY DESIGN RATING Energy Design Ratings Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 54.1 23.9 Proposed Designs North Facing 47.2 20.8 6.9 3.1 East Facing 50.3 23.9 3.8 0 South Facing 47.2 20.8 6.9 3.1 West Facing 47.9 21.5 6.2 2.4 RESULT:3:COMPLIES ¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment ² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries ³ Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 5.86 kWdc 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.14 0.24 1.9 88.8 Space Cooling 94.13 74.65 19.48 20.7 IAQ Ventilation 11.34 11.34 0 0 Water Heating 9.67 8.77 0.9 9.3 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 117.28 95 22.28 19 Space Heating 2.14 0.61 1.53 71.5 Space Cooling 94.13 84.21 9.92 10.5 IAQ Ventilation 11.34 11.34 0 0 Water Heating 9.67 8.77 0.9 9.3 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 117.28 104.93 12.35 10.5 Space Heating 2.14 0.94 1.2 56.1 Space Cooling 94.13 73.8 20.33 21.6 IAQ Ventilation 11.34 11.34 0 0 Water Heating 9.67 8.77 0.9 9.3 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 117.28 94.85 22.43 19.1 Space Heating 2.14 0.58 1.56 72.9 Space Cooling 94.13 76.68 17.45 18.5 IAQ Ventilation 11.34 11.34 0 0 Water Heating 9.67 8.77 0.9 9.3 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 117.28 97.37 19.91 17 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 5 NA Premium Fixed (roof mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Indoor air quality, balanced fan •Non-standard roof reflectance •Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •-- None -- HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1 V122 (2179)2179 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Home Conditioned HVAC System1 2179 9.04 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 305 69 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 350 45 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 545 198 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 499.6 30 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 239.9 17.8 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 149.1 0 n/a Roof Home R-0+R-22 BD n/a n/a 2179 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 794 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 239.9 112 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 358.8 17.8 90 Right Exterior Wall __Garage__R-0 Wall 270 Right 208.9 0 90 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 45 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 45 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 198 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 30 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 24 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 112 1 Door 4 Left Exterior Wall 17.8 0.7 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2179 187 None 80%No Slab-on-Grade 2 __Garage__794 89 None 0%No 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-9.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-22 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 981.6 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1)n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 1 0 0.93-UEF 200000- Btu/Hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System1 Heating and cooling system other Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Required Required Required 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 1-1 123 0.853659 Balanced HRV 75 n/a 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2021-07-15T16:12:55-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   16:14:44 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Cristela Lujan Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2021-07-15 16:29:11 R16-18-20136 702-365-8080 Laura Jew Beazer Homes 310 Commerce, Suite 150 Irvine, CA 92602 2021-07-15 21:08:51 N/A 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 221-P010145950A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 GENERAL INFORMATION 01 Project Name Plan 2 V123 (2333) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92210 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)2333 19 Glazing Percentage (%)16.25% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 ENERGY DESIGN RATING Energy Design Ratings Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 52.9 23.6 Proposed Designs North Facing 47 22.5 5.9 1.1 East Facing 47.8 23.3 5.1 0.3 South Facing 48.1 23.6 4.8 0 West Facing 45.9 21.4 7 2.2 RESULT:3:COMPLIES ¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment ² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries ³ Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 6.13 kWdc 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.31 0.49 1.82 78.8 Space Cooling 95.52 79.11 16.41 17.2 IAQ Ventilation 10.59 10.59 0 0 Water Heating 9.09 8.24 0.85 9.4 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 117.51 98.43 19.08 16.2 Space Heating 2.31 0.57 1.74 75.3 Space Cooling 95.52 81.54 13.98 14.6 IAQ Ventilation 10.59 10.59 0 0 Water Heating 9.09 8.24 0.85 9.4 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 117.51 100.94 16.57 14.1 Space Heating 2.31 1.11 1.2 51.9 Space Cooling 95.52 81.77 13.75 14.4 IAQ Ventilation 10.59 10.59 0 0 Water Heating 9.09 8.24 0.85 9.4 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 117.51 101.71 15.8 13.4 Space Heating 2.31 0.89 1.42 61.5 Space Cooling 95.52 75.09 20.43 21.4 IAQ Ventilation 10.59 10.59 0 0 Water Heating 9.09 8.24 0.85 9.4 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 117.51 94.81 22.7 19.3 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 4.99 NA Premium Fixed (roof mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Indoor air quality, balanced fan •Non-standard roof reflectance •Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •-- None -- HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2 V123 (2333)2333 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Home Conditioned HVAC System1 2333 9.04 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 0 Front 227.1 54 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 90 Left 510.2 147 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS +R4 180 Back 545 140 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 270 Right 666.1 62 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 317.9 17.8 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 158.2 0 n/a Roof Home R-0+R-22 BD n/a n/a 2333 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 767 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 317.9 168 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 212.7 17.8 90 Right Exterior Wall __Garage__R-0 Wall 270 Right 74.2 0 90 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 30 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 147 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 140 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 62 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 24 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 168 1 Door 4 Left Exterior Wall 17.8 0.7 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2333 214 None 80%No Slab-on-Grade 2 __Garage__767 67 None 0%No 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS +R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-9.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-22 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 1051.0 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1)n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 1 0 0.93-UEF 200000- Btu/Hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System1 Heating and cooling system other Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Required Required Required 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 1-1 123 0.853659 Balanced HRV 75 n/a 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2021-07-15T15:31:49-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:33:38 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Cristela Lujan Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2021-07-15 16:29:49 R16-18-20136 702-365-8080 Laura Jew Beazer Homes 310 Commerce, Suite 150 Irvine, CA 92602 2021-07-15 21:08:51 N/A 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 221-P010145951A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 GENERAL INFORMATION 01 Project Name Plan 3 S812 (2670) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92210 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.31 18 Total Cond. Floor Area (ft 2)2670 19 Glazing Percentage (%)13.37% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 ENERGY DESIGN RATING Energy Design Ratings Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 52.3 23.5 Proposed Designs North Facing 46.6 22 5.7 1.5 East Facing 47.6 23 4.7 0.5 South Facing 48 23.5 4.3 0 West Facing 45.4 20.8 6.9 2.7 RESULT:3:COMPLIES ¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment ² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries ³ Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 6.22 kWdc 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.98 0.42 1.56 78.8 Space Cooling 85.23 70.8 14.43 16.9 IAQ Ventilation 9.26 9.26 0 0 Water Heating 7.99 7.24 0.75 9.4 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 104.46 87.72 16.74 16 Space Heating 1.98 0.46 1.52 76.8 Space Cooling 85.23 73.58 11.65 13.7 IAQ Ventilation 9.26 9.26 0 0 Water Heating 7.99 7.24 0.75 9.4 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 104.46 90.54 13.92 13.3 Space Heating 1.98 1.08 0.9 45.5 Space Cooling 85.23 74.3 10.93 12.8 IAQ Ventilation 9.26 9.26 0 0 Water Heating 7.99 7.24 0.75 9.4 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 104.46 91.88 12.58 12 Space Heating 1.98 0.87 1.11 56.1 Space Cooling 85.23 66.79 18.44 21.6 IAQ Ventilation 9.26 9.26 0 0 Water Heating 7.99 7.24 0.75 9.4 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 104.46 84.16 20.3 19.4 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 5.15 NA Premium Fixed (roof mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Indoor air quality, balanced fan •Non-standard roof reflectance •Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •-- None -- HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 S812 (2670)2670 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Home Conditioned HVAC System1 2670 9.04 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 174.8 35 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 726.6 151 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 481.4 141 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 537.1 50 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 318 17.8 n/a South Interior Surface 2x Home>>__Garage__Garage R-15 Wall n/a n/a 12.1 0 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 184.7 0 n/a Roof Home R-0+R-22 BD n/a n/a 2670 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 561 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 306.6 145 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 90.8 0 90 Right Exterior Wall __Garage__R-0 Wall 270 Right 275.5 73.8 90 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 15 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 151 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 141 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 50 0.28 NFRC 0.22 NFRC Bug Screen Window 5 Window Front Exterior Wall Front 0 1 33 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 20 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 112 1 Door 4 Right Exterior Wall 73.8 0.7 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2670 211 None 80%No 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade 2 __Garage__561 74 None 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-9.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-22 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 1202.8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1)n/a None n/a 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 1 0 0.93-UEF 200000- Btu/Hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System1 Heating and cooling system other Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 1-1 123 0.853659 Balanced HRV 75 n/a 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2021-07-15T15:21:23-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-15   15:23:12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Cristela Lujan Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2021-07-15 16:30:37 R16-18-20136 702-365-8080 Laura Jew Beazer Homes 310 Commerce, Suite 150 Irvine, CA 92602 2021-07-15 21:08:51 N/A 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 221-P010145957A-000000000-0000 2021-07-15 21:08:51 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 GENERAL INFORMATION 01 Project Name Plan 4 V067 (3006) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2019 06 Zip code 92210 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)3006 19 Glazing Percentage (%)15.50% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 ENERGY DESIGN RATING Energy Design Ratings Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 51.1 23.1 Proposed Designs North Facing 44.7 19.4 6.4 3.7 East Facing 48.4 23.1 2.7 0 South Facing 44.3 19 6.8 4.1 West Facing 45.7 20.3 5.4 2.8 RESULT:3:COMPLIES ¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment ² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries ³ Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 6.62 kWdc 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.86 0.33 1.53 82.3 Space Cooling 84.53 68.53 16 18.9 IAQ Ventilation 8.22 8.22 0 0 Water Heating 7.09 6.43 0.66 9.3 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 101.7 83.51 18.19 17.9 Space Heating 1.86 0.86 1 53.8 Space Cooling 84.53 78.58 5.95 7 IAQ Ventilation 8.22 8.22 0 0 Water Heating 7.09 6.43 0.66 9.3 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 101.7 94.09 7.61 7.5 Space Heating 1.86 1.14 0.72 38.7 Space Cooling 84.53 66.48 18.05 21.4 IAQ Ventilation 8.22 8.22 0 0 Water Heating 7.09 6.43 0.66 9.3 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 101.7 82.27 19.43 19.1 Space Heating 1.86 0.72 1.14 61.3 Space Cooling 84.53 70.98 13.55 16 IAQ Ventilation 8.22 8.22 0 0 Water Heating 7.09 6.43 0.66 9.3 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 101.7 86.35 15.35 15.1 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 5.85 NA Premium Fixed (roof mount)Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Indoor air quality, balanced fan •Non-standard roof reflectance •Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •-- None -- HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 4 V067 (3006)3006 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Home Conditioned HVAC System1 3006 9.04 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 0 Front 312.5 90 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 90 Left 487.4 40 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS R4 180 Back 499.6 304 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 270 Right 663.1 52 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 187.7 17.8 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 354.2 0 n/a Right Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 172.6 0 n/a Roof Home R-0+R-22 BD n/a n/a 3006 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 610 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 187.7 112 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 186.2 16.7 90 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.13 0.92 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 70 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 40 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 304 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 52 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 20 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 112 1 Door 4 Left Exterior Wall 16.7 0.7 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 3006 216 None 80%No Slab-on-Grade 2 __Garage__610 41 None 0%No 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-22 None / None 0.043 Roofing: 10 PSF (RoofTile) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-9.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-22 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 1354.2 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1)n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 1 0 0.93-UEF 200000- Btu/Hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System1 Heating and cooling system other Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 13 16 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Required Required Required 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 1-1 125 0.84 Balanced HRV 75 n/a 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2021-07-13T09:12:40-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006) - S1.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-07-13   09:14:29 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Cristela Lujan Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2021-07-15 16:31:28 R16-18-20136 702-365-8080 Laura Jew Beazer Homes 310 Commerce, Suite 150 Irvine, CA 92602 2021-07-15 21:08:52 N/A 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 221-P010145958A-000000000-0000 2021-07-15 21:08:52 CalCERTS inc.